275 4th St 2014 HVAC CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
J " ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 14-00000920 Date 6/10/14
Property Address . . . . . . 275 14TH ST
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 cu 1 ahu 1 . 5 tons
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
SECKINGER, RAY L & BRIDGET A DONOVAN HEATING & AIR
275 14TH ST 315 SIXTH AVENUE SOUTH
ATLANTIC BEACH FL 32233 JACKSONVILLE BEACH FL 32250
(904) 241-3785
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 87 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 12/07/14
----------------------------------------------------------------------------
Special Notes and Comments
STICKER FOR OVERCURRENT PROTECTION MUST
BE ON A/C EQUIPMENT PRIOR TO
INSPECTION. FAILURE TO COMPLY WILL
RESULT IN A FAILED INSPECTION AND
REINSPECT FEES . NO EXCEPTIONS .
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 87 . 00 87 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 91 . 00 91 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904) 247-5826 Fax (904) 247-5845
lOB ADDRESS: 1 S ST PERMIT#
PROJECT VALUE $ 4500'6 ARI# _702- ISO REQUIRED
Air Handling Equipment Only YAir Handling Unit & Condenser Condenser Only
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating REQUIRED
Duct Systems: Total CFM
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit (,S
Heat: Unit Quantity�— BTU's Per Unit I gec�. Seer Rating 1�
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
Tis application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name �ecti L r Phone Number aye _�2.
00
Mechanical Company 1)o•jad A� NC-�T �t( Office Phone t 3? Fax d Y 137Y
Co. Address: 31 S�t Lyn- S ! City �T►4x Bch State a—Zip nz5CU
License Holder(Print): Lam! ( ( 1 a n., ; 1r.��o /A�l State Certification/Registration# 3��
Notarized Signature of License Holder
�Y'esyk;. RICHARD TOMPKINS Before me is day 20
Commission#FF 040399
eI Expires July 29,2017 Signature of Notary Public
•, pF F. Bonded TMu Troy Fain Insuranw Bpp.�8,5-7079
Job:
+ wrightsoft Project Summary Date: 6/6114
Entire House By: Brandon Zaharie
Donovan Heat & Air
315 6th ave south,Jacksonville Beach,FL 32250 Phone:241-3785 Email: brandon@donovanac.com
Project • •
For: Seckinger
275 14 st,Atlantic Beach, FL 32233
Notes:
Design Information
Weather: Jacksonville Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 39 °F Outside db 95 °F
Inside db 68 °F Inside db 75 °F
Design TD 29 °F Design TD 20 °F
Daily range L
Relative humidity 50 %
Moisture difference 53 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 9277 Btuh Structure 10200 Btuh
Ducts 1227 Btuh Ducts 1383 Btuh
Central vent (28 cfm) 894 Btuh Central vent (28 cfm) 617 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 11397 Btuh Use manufacturer's data n
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 12200 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction qualityAverage
Fireplaces 1 (Average) Structure 1434 Btuh
Ducts 293 Btuh
Heating Cooling Central vent (28 cfm) 1015 Btuh
Area (ft2 480 480 Equipment latent load 2741 Btuh
Volume �ft-) 4320 4320
Air changes/hour 0.89 0.32 Equipment total load 14941 Btuh
Equiv.AVF (cfm) 64 23 Req. total capacity at 0.70 SHR 1.5 ton
Heating Equipment Summary Cooling Equipment Summary
Make American Standard Make American Standard
Trade Trade
Model AM7AOA24 Gem eF_Ct � AM7AOA24
ARI ref no. 7021567 C—e+ l -.,.1 4A6H5018
ARI ret no. 7021567
EfficiencY Y
8.4 HSPF Efficienc 15 SEER
Heating input Sensible cooling 10779 Btuh
Heating output 15323 Btuh @ 47°F Latent cooling 4620 Btuh
Temperature rise 27 °F Total cooling 15399 Btuh
Actual air flow 513 cfm Actual air flow 513 cfm
Air flow factor 0.049 cfm/Btuh Air flow factor 0.044 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.82
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
-4+ wrightsoTt Right-Suite®Universal 7.1.01 RSU05996 2014-Jun-06 12:05:34
ACCK C:\Users\Sales\Documents\Wrightsoft HVAC\1.5 TON.rup Calc=MJ8 Orientation=N Page 1