1982 W Sevilla Blvd 2014 HVAC CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
'' s) ATLANTIC BEACH,FL 32233
INSPECTION PHONE LINE 247-5814
r�<JSl!>i?
Application Number . . . . 14-00000919 Date 6/10/14
Property Address . . . . . . 1982 W SEVILLA BLVD
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . PLANNED UNIT DEVELOPMENT
Application valuation . . . . 0
--------------------------------------------------------------------
Application desc
1 cu 1 ahu 3 tons
-----------------------------------------------------------------
Owner Contractor
-
------------------------
-----------------------
ARIEFF, DAVID DONOVAN HEATING & AIR
1982 W SEVILLA BLVD 315 SIXTH AVENUE SOUTH
ATLANTIC BEACH FL 32233 JACKSONVILLE BEACH FL 32250
(904) 241-3785
---------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee 99 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 12/07/14
-----------------------------------------------------------
Special Notes and Comments
STICKER FOR OVERCURRENT PROTECTION MUST
BE ON A/C EQUIPMENT PRIOR TO
INSPECTION. FAILURE TO COMPLY WILL
RESULT IN A FAILED INSPECTION AND
REINSPECT FEES . NO EXCEPTIONS .
--------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
-----------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------
Permit Fee Total 99 . 00 99 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 103 . 00 103 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
.� CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904) 247-5826 Fax (904) 247-5845
10B ADDRESS: I Q�� V �a 'd PERMIT#
PROJECT VALUE $ �� ARI# 2j(ay S9 q5 REQUIRED
Air Handling Equipment Only )( Air Handling Unit & Condenser Condenser Only
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING3YSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit l�
Heat: Unit Quantity BTU's Per Unit 6 0 00 Seer Rating
REQUIRED
Duct Systems: Total CFM
FIRE PREVENTION 3 sets of plans)
Fire Sprinkler System Quantity (Requires
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
its application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance�of construction.
Property Owners Name !J Avg�( Alr--ISR Phone Number CC// 3_7P8
tt l� Office Phone � j 37 S Fax
Mechanical Company �ONO�IA� r1El� ��
City State F_L_Zip20Z0
Co. Address: 31 S
License Holder(Print): �/�� !� �� l J"^�'°'' to Certi ation/Registration# 3q�� l
Notarized Signature of License Holder.
,• RICHARD TOMPKINS Before me this�_day of Lr� 20 J
ti�isyy.
' Commission#FF 040399
Expires July 29,2017 Signature of Notary Public r
'','F,'•p er••° Bonded Th.Ty Fein W-SMO gpQ385 7019
Job:
+ wrightsoft Project Summary Date: June 9,2014
Entire House By: Aaron Thacker
Donovan Heat&Air
315 6th Ave S, Jacksonville Beach, FL 32250 Phone:904241-3785 Fax:904-241-3745 Email:aaron@donovanac.com Web:www.DonovanAC.com
For: David Arieff
1982 Sevilla Blvd,Atlatnic Beach, FL 32233
Notes:
Design Information
Weather: Jacksonville Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 39 °F Outside db 95 °F
Inside db 70 °F Inside db 75 °F
Design TD 31 °F Design TD 20 °F
Daily range L
Relative humidity 50
Moisture difference 53 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 26705 Btuh Structure 20836 Btuh
Ducts 4945 Btuh Ducts 4814 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 31649 Btuh Use manufacturer's data n
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 25651 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average 1154 Btuh
Fireplaces 0 Structure
Ducts 2066 Btuh
Heating Cooling Central vent (0 cfm) 0 Btuh
Area (ft2) 1040 1040 Equipment latent load 3220 Btuh
Volume (ft') 8320 8320
Air changes/hour 0.45 0.23 Equipment total load 28871 Btuh
Equiv.AVF (cfm) 62 32 Req. total capacity at 0.70 SHR 3.1 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade BASE 15 PURON HP Trade BASE
15 536 UROON HP
Model 25HBC536A**30 Cond Coil FX4DN(B,F)037
AHRI ref no3645945
AHRI ref no3645945
Efficiency 8.7 HSPF Efficiency 12.5 EER, 15 SEER
Heating input Sensible cooling 24360 Btuh
Heating output 35400 Btuh @ 47°F Latent cooling 10440 Btuh
Temperature rise 28 °F Total cooling 34800 Btuh
Actual air flow 1160 cfm Actual air flow 1160 cfm
Air flow factor 0.037 cfm/Btuh Air flow factor 0.045 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.89
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
2014-Jun-09 09:52:43
wriightsoft Right-Suite®Universal 8.0.24 RSU05995 Page 1
ACC' C:\Users\Owner\Documents\Wrightsoft MVAC\Bogus 3 ton.rup Calc=MJ8 Front Door faces: S