1965 Seminole Rd 2014 HVAC CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 14-00000888 Date 6/03/14
Property Address . . . . . . 1965 SEMINOLE RD
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . RES GEN MF DISTRICT
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
3 TONS 36K BTUS
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
MAHER, JEFFREY AIR SOURCE AMERICA INC
1965 SEMINOLE RD 2615 CRYSTAL COVE CT
ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32224
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 99 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 11/30/14
----------------------------------------------------------------------------
Special Notes and Comments
STICKER FOR OVERCURRENT PROTECTION MUST
BE ON A/C EQUIPMENT PRIOR TO
INSPECTION. FAILURE TO COMPLY WILL
RESULT IN A FAILED INSPECTION AND
REINSPECT FEES . NO EXCEPTIONS .
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 99 . 00 99 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 103 . 00 103 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904) 247-5826 Fax (904) 247-5845
JOBADDRESS: \ '�kUS C\ PERmrr#
PROJECT VALUE $3864.00 ARI# 7043629 REQUIRED
Air Handling Equipment Only –X—Air Handling Unit & Condenser Condenser Only
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Ratin
Duct Systems: Total CFM UIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity I Tons Per Unit 3
Heat: Unit Quantity I BTU's Per Unit 36,000 Seer Rating
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty_ Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
#Water Heaters Solar Collection Systems
Tanks(gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name Jeffrey Maher Phone Number 904-563-3161
Mechanical Company Air Source America Office Phone 904-233-883 IFax9O4-372-9379
Co. Address: 207 North 20th Street, Jax Beach, FL 32250 City Jax Beach State FL_Zip 32250
License Holder(Print): Jason State Certification/Registration#CAC 1816716
Notarized Signature of License Ho
o"y...... Catherine H.Smith Before me this 2 day pf June A2014
C�
0!,�yssjoN#EEO 10240
EXPiRES:JULY 19.2014 Signature of Notary Public lc�2�lt
WWWAARONNOTARYcom
CERTIFIED
IL www.all ri directory.or g
Certificate of Product Ratings
AHRI Certified Reference Number: 5725542 Date: 6/3/2014
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: 13HPX-036-230-17
Indoor Unit Model Number: CBX25UH-036-230-*
Manufacturer: LENNOX INDUSTRIES, INC.
Trade/Brand name: 13HPX SERIES
Series name:
Manufacturer responsible for the rating of this system combination is LENNOX INDUSTRIES, INC.
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unita VI Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AH -sponsored, independent,third
party testing:
Cooling Capacity (Btuh): 34400
EER Rating (Cooling): 11.00
SEER Rating (Cooling): 13.00
Heating Capacity(Btuh) @D 4 7 F: 33400
Region IV HSPF Rating (Heating): 8.20
Heating Capacity(Btuh) 9 17 F: 21400
Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate.
DISCLAIMER
AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for,
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the
unauthorized atteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the
directory at www.ahridirectory.org.
TERMS AND CONDITIONS ,and ANN
This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,persomm inated;
confidential reference purposes.The contents of this Certificate may not,in whole or In part,be reproduced;copied;disse 1. Jrm a
entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individua, AIR-CONDITIONING,HEATING.
personal and confidential reference. &REFRIGERATION INSTITUTE
CERTIFICATE VERIFICATION
The information for the model cited on this certificate can be verified at www.ahridirectory.org,click on"Verify Certificate"link we make life better-
and enter the AHRI Certified Reference Number and the date on which the certificate was Issued,
which is listed above,and the Certificate No.,which is listed at bottom right. FCERTIFICATE NO.: 110462682342570305
@2014 Air-Conditioning, Heating,and Refrigeration Institute
Job:
+ wrightsoft Right J@ Mobile Report Date: 6/3/2014
Entire House By:
AL
Project Information
For: Jeffrey Maher
1965 Seminole Road,Atlantic Beach, FL 32233
Design Conditions
Location: Indoor: Heating Cooling
Jacksonville/Craig, FL, US Indoor temperature (T) 70 75
Elevation: 39 ft Design TD(T) 35 16
Latitude: 30'N Relative humidity 30 50
Outdoor: Heating Cooling Moisture difference (gr/lb) 8.9 55.4
Dry bulb(T) 35 91 Infiltration:
Da i ly range (T) - 17 ( M Method Simplified
V\Iet bulb('F) - 77 Construction quality Average
Wind speed(mph) 15.0 7.5 Fireplaces 0
Component Btu hM Btuh %of load
Walls 3.2 3360 13.5 VAIS lrfitb-�tcn
Glazing 20.1 9229 37.0
Doors 13.7 288 1.2
Ceilings 0 0 0
Floors 4.5 8126 32.5
Infiltration 2.6 3967 15.9
Ducts 0 0 Rccrs
Piping 0 0
Humidification 0 0 Chff
Ventilation 0 0
Adjustments 0
Total 24971 i 100.01
0- 0 0
Component Btu h/fl:2 Btuh %of load —
Walls 1.3 1403 5.7 VWIS
*I,n
Glazing 44.2 20322 81.9
Doors 11.4 239 1.0
Ceilings 0 0 0
Floors 0 0 0
Infiltration 0.6 967 3.9
Ducts 0 0
Ventilation 0 0
Internal gains 1890 7.6
Blower 0 0
Adjustments 0 Gadrg
Total 24821 100.0
Latent Cooling Load 2633 Btuh
Overall U-value=0.116 Btuh/ft2-'F
WARNING.-window to floor area ratio 25.6%-more than 25%.
2014-Jun-03 04:32:17
wrilightSOft Right-Suite@ universal 2013 13.0.10 Right J8 Mobile Page 1
*—_Ck ...\wstmp\6b24bdOO-786e-44ec-bc33-4617a89lcffd.rup Calc=MJ8 FrontDoorfaces: N