615 Atlantic Blvd 2014 HVAC CITY OF ATLANTIC BEACH
j 800 SEMINOLE ROAD
J =" ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 14-00000988 Date 6/19/14
Property Address . . . . . . 615 ATLANTIC BLVD
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . COM GENERAL DISTRICT
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 cu 1 ahu 2 ton
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
CORAL REEF PROPERTY HOLDINGS DONOVAN HEATING & AIR
615 ATLANTIC BLVD 315 SIXTH AVENUE SOUTH
ATLANTIC BEACH FL 32233 JACKSONVILLE BEACH FL 32250
(904) 241-3785
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 91 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 12/16/14
----------------------------------------------------------------------------
Special Notes and Comments
STICKER FOR OVERCURRENT PROTECTION MUST
BE ON A/C EQUIPMENT PRIOR TO
INSPECTION. FAILURE TO COMPLY WILL
RESULT IN A FAILED INSPECTION AND
REINSPECT FEES . NO EXCEPTIONS .
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 91 . 00 91 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 95 . 00 95 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
//'' ff Ph(904) 247-5826 Fax (904) 247-5845
[oB ADDRESS: 1p 1 5 A. C n)-Y,- y PERMIT#
PROJECT VALUE $ 4 Spa w ARI# 4Z/ 7 �-72 REQUIRED
Air Handling Equipment Only X Air Handling Unit & Condenser Condenser Only
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity I Tons Per Unit Z I
Heat: Unit Quantity i BTU's Per Unit71000 Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
►is application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name CD{aI f-e-J (ayi, rral 64 d> Phone Number,�2 yt 41V1
Mechanical Company ')0 Office PhonQ�0 37kS"Fax-y13741._
Co. Address: ±' �vt s City State r_1 ZipS1150
License Holder(Print): �' ►^^ `� 0 0 4,% State Certification/Registration#
Notarized Signature of License Holder �-
e�orsec-ooa•��i�d w,i wi casae ,,ay•d'�
Before me this day of 20_14__
80Z'6Z AInr sandx3 w
66CM JJ#uolssltaL �= Signature of Notary Public ►
SNINdW i 0WH3N �;; ,
-- Project Summary Job:
+�+ wrightsoft � Summary Date: June 16,2014
Entire House By: Aaron Thacker
Donovan Heat&Air
315 6th Ave S,Jacksonville Beach,FL 32250 Phone-904-241-3785 Fax:904241-3745 Email:aaron@donovanac.com Web:www.DonovanAC.com
Project • •
For: Coral Reef Animal Hospital
615 Atlantic Blvd, Atlantic Beach, FL 32233
Notes:
Design Information
Weather: Jacksonville Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 39 °F Outside db 99 °F
Inside db 70 °F Inside db 75 °F
Design TD 31 °F Design TD 24 °F
Daily range L
Relative humidity 50
Moisture difference 69 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 10754 Btuh Structure 9911 Btuh
Ducts 1732 Btuh Ducts 3087 Btuh
Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 12485 Btuh Use manufacturer's data n
Rate/swing multiplier 1.04
Infiltration Equipment sensible load 13518 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 2241 Btuh
Ducts 891 Btuh
Heating Cooling Central vent (0 cfm) 0 Btuh
Area (ft') 1140 1140 Equipment latent load 3132 Btuh
Volume (ft ) 9120 9120
Air changesmour 0.45 0.23 Equipment total load 16650 Btuh
Equiv.AVF (cfm) 68 35 Req. total capacity at 0.70 SHR 1.6 ton
Heating Equipment Summary Cooling Equipment Summary
Make Mitsubishi Make Mitsubishi
Trade Mr Slim Trade Mr Slim
Model MUZ-GE24NA Cond MUZ-GE24NA
AHRI ref no.4217872 Coil MSZ-GE24NA
AHRI ref no.4217872
Efficiency 9.1 HSPF Efficiency 14.7 EER, 18 SEER
Heating input Sensible cooling 14700 Btuh
Heating output 20896 Btuh @ 47°F Latent cooling 6300 Btuh
Temperature rise 27 °F Total cooling 21000 Btuh
Actual air flow 700 cfm Actual air flow 700 cfm
Air flow factor 0.056 cfm/Btuh Air flow factor 0.054 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.81
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
+�+ wrightsoft 2014-Jun-18 14 47:28
Right-Suite®Universal 8.0.24 RSU05995 Page 1
k Cr_ C:\Users\Owner\Documents\Wrightsoft HVAC\Bogus 2 ton rup Calc=MJ8 Front Door faces W