Loading...
615 Atlantic Blvd 2014 HVAC CITY OF ATLANTIC BEACH j 800 SEMINOLE ROAD J =" ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 14-00000988 Date 6/19/14 Property Address . . . . . . 615 ATLANTIC BLVD Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . COM GENERAL DISTRICT Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu 2 ton ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ CORAL REEF PROPERTY HOLDINGS DONOVAN HEATING & AIR 615 ATLANTIC BLVD 315 SIXTH AVENUE SOUTH ATLANTIC BEACH FL 32233 JACKSONVILLE BEACH FL 32250 (904) 241-3785 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 91 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 12/16/14 ---------------------------------------------------------------------------- Special Notes and Comments STICKER FOR OVERCURRENT PROTECTION MUST BE ON A/C EQUIPMENT PRIOR TO INSPECTION. FAILURE TO COMPLY WILL RESULT IN A FAILED INSPECTION AND REINSPECT FEES . NO EXCEPTIONS . ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 91 . 00 91 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 95 . 00 95 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 //'' ff Ph(904) 247-5826 Fax (904) 247-5845 [oB ADDRESS: 1p 1 5 A. C n)-Y,- y PERMIT# PROJECT VALUE $ 4 Spa w ARI# 4Z/ 7 �-72 REQUIRED Air Handling Equipment Only X Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity I Tons Per Unit Z I Heat: Unit Quantity i BTU's Per Unit71000 Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read ►is application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name CD{aI f-e-J (ayi, rral 64 d> Phone Number,�2 yt 41V1 Mechanical Company ')0 Office PhonQ�0 37kS"Fax-y13741._ Co. Address: ±' �vt s City State r_1 ZipS1150 License Holder(Print): �' ►^^ `� 0 0 4,% State Certification/Registration# Notarized Signature of License Holder �- e�orsec-ooa•��i�d w,i wi casae ,,ay•d'� Before me this day of 20_14__ 80Z'6Z AInr sandx3 w 66CM JJ#uolssltaL �= Signature of Notary Public ► SNINdW i 0WH3N �;; , -- Project Summary Job: +�+ wrightsoft � Summary Date: June 16,2014 Entire House By: Aaron Thacker Donovan Heat&Air 315 6th Ave S,Jacksonville Beach,FL 32250 Phone-904-241-3785 Fax:904241-3745 Email:aaron@donovanac.com Web:www.DonovanAC.com Project • • For: Coral Reef Animal Hospital 615 Atlantic Blvd, Atlantic Beach, FL 32233 Notes: Design Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 99 °F Inside db 70 °F Inside db 75 °F Design TD 31 °F Design TD 24 °F Daily range L Relative humidity 50 Moisture difference 69 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 10754 Btuh Structure 9911 Btuh Ducts 1732 Btuh Ducts 3087 Btuh Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 12485 Btuh Use manufacturer's data n Rate/swing multiplier 1.04 Infiltration Equipment sensible load 13518 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2241 Btuh Ducts 891 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft') 1140 1140 Equipment latent load 3132 Btuh Volume (ft ) 9120 9120 Air changesmour 0.45 0.23 Equipment total load 16650 Btuh Equiv.AVF (cfm) 68 35 Req. total capacity at 0.70 SHR 1.6 ton Heating Equipment Summary Cooling Equipment Summary Make Mitsubishi Make Mitsubishi Trade Mr Slim Trade Mr Slim Model MUZ-GE24NA Cond MUZ-GE24NA AHRI ref no.4217872 Coil MSZ-GE24NA AHRI ref no.4217872 Efficiency 9.1 HSPF Efficiency 14.7 EER, 18 SEER Heating input Sensible cooling 14700 Btuh Heating output 20896 Btuh @ 47°F Latent cooling 6300 Btuh Temperature rise 27 °F Total cooling 21000 Btuh Actual air flow 700 cfm Actual air flow 700 cfm Air flow factor 0.056 cfm/Btuh Air flow factor 0.054 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. +�+ wrightsoft 2014-Jun-18 14 47:28 Right-Suite®Universal 8.0.24 RSU05995 Page 1 k Cr_ C:\Users\Owner\Documents\Wrightsoft HVAC\Bogus 2 ton rup Calc=MJ8 Front Door faces W