Loading...
1665 Selva Mrina Dr 2014 Plans bath remodel DocuSign Envelope ID:D2D3265B-Al9A-4Cl4-8lA9-735lA56ClA9B REVISIONS S-1 I IN F RI C T E E R E I E I G S c 0 I R P E E 0 T A A R A 0 LL DROPPED SOFFIT Lij LJ LA ui I -A I ----------- t ------------I ui < EXI $TING PLAN Clow "�l 3 SHEET NO.: A-1 EXISTING PLAN SITE ADDRESS. 1665 SELVA MARINA DR, ATL. BEACH, FL 32233 DRAWN BY: 1665 ELVA MARINA DR ATL ,NTIC BEACH , FL 32233 DocuSign Envelope ID:D2D3265B-Al9A-4Cl4-8lA9-735lA56ClA9B REVISIONS WOOD FRAME CONSTRUCTION CODE COMPLIANT WINDOW INSTALLATION METPOD (FBIC-R7103,0) Z-221 21-411 WEATHER RESITIVE BARRIER (WIRZ) Af=I=LIED f9RIOR TO THE WINC>OW INSTALLATION. 31-8" 3'-811 2 FLASHING AffLIED THE MOUNTING FLANGE. STEPS SECTION A (DIN WATER SHEDDING FASHION, STARTING AT THE BASE OF THROUGH WINDOW JAM15 THE WALL 4 WORKING TOWARDS 3050(NEW) 3050 'NEW) THE TOP, INSTALL THE WRIS 1050��LWA To THE FACE OF THE SHEATHW-% x (2)APPLY ISILL FLASHING (4orwl) APPLY JAMB FLASHING G) @ APPLY BEAD OF SEALANT INFILL EXISTING ARDUND THE TOP 4 2 SIDES 8'-l"CLG WINDOW AND ADD OF THE BACK SIDE (INTERIOR _69- DOOR SURFACE)OF WINDOW MOUNTIW_%FLAWGE. APPLY oiscmmuous BEAD UWmFin OF SEALANT TO 50TTOM FLASHW FLANGE,LEAVING (2)2N GAPS. SEALANT BEAD BETWEEN 4" &MMEDIATELY INSTALL WINDOW @APPLY A V'NOM.DIA. MOUNTING FLANGE AND BEAD OF SEALANT TO T14E FLASHING. (1)APPLY BEAD OF: SEALANT BACKSIDE (INTERIOR)OF: THE 68 DR(N W) ACROSS THE FACE OF MOUNTING FLANGE AROUND MOUNTING FLANGE AT HEAD T14E ENT114M PERIMETEFt U) PLACE BEAD IN LINE WITH U) NEW ROOF RID APPLY 14EAD FLASHING ANY PRE-PUNCHED HOLES FLASHING AT HEAD EXTENDS REMOVE PREVIOUSLY APPLIED OR$LOTS. I" BEYOND JAMB FLASHING. 00 TAPE,ALLOWING WRI5 TO LAY FLAT OVER HEAD FLASHING. APPLY NEW SI-EATHIW3 TAPE M NON STRUCTURAL HEAD FLASHING OVER PlAiGONAL CUT - SEE ROOM ALTERATION IN DIAGRAM. APPLY A C4NT SEAL ALONG < GARAGE Q MOUNTING FLANGE AT T44E HEAD. FLASHING GOES OVER M MOUNITING FL ECURE ANGE. EMBED 41 -EA0 FLASHING HEAD 150TTOM OF I F AGAINST SEALANT (FLASHING GOES OVER SEALANT). EXTEND HEAD FLASHING BEYOND SAC-44 JAMB FLASHW_% FASTEN IN PLACE. (EXISTING GARAGE) �Mx G) U. REMOVE 0 AFT ER INSTALLATION EXISTING DR EXISTING SEAL ALL CORNERS OF NON LOAD (F2) A MEC44ANIC-ALLY JOINED BEARING 3050(NEW) 3050(NEA) FRAMES TO SEAL FRAME SOFFIT SEAM JUNCTURE. EXTEND JAMB FLASHING A To OVERLAP SILL r-LAS441W.L EXTEND 1-2 '1 31-8" 31-811 2 22"' Uj jAm FLASHING 0,15" (220"11)A50VE ROUGH OPENING AT HEAD. SEALANT APPLY TAM AT COWERS TO U) z TEMPORARILY HOLD FLASHING IN PLACE SILL FLASHING UNTIL WR15 16 APPLIED. t 0 wm AND ADJUST WINDOW TO ACHIEVE SMARE, (EXISTINC IVING) (EXISTING COURTYARD) PLUMB,AND LEVEL CONDITION. USE CORROSION RESISTANT FASTENERS. FASTEN WINDOWS PER (D WINDOW MANUFACTURER FASTENER SPECIFICATIONS. Uj I (DUJEATHER RF-51STANT BARRIER (WIRD) AT A 45 DEGREE ANGLE,CAREFULLY CUT THE BARRIER ON A DIAGONAL. GENTLY RAISE THE TOP EDGE OF T44E BAWER UP AND TAPE T14E JOR TOP CXMRNERS AND CENTER TO THE EXTER WR5 SURFACE ABOVE. INTERIOR VIEW CN TOP LEFT COFNER OF: WNDOW Uj NOTES: 1. flashing to be fle)dble self-adhesive type(min.40 wide) . .. .. . sill pan flashing "'x 2. cover sill to at least depth of window, plus 2w onto face of wrb NEW FLOOR PLAN -10TOO surface ptional) 3. the pan shall direct water to the e)dedor over sill flashing sill plaw 4. install flashing around remining window unit 5. weather resistive barder to fbrm water shedding laps 'Ilk see note#2 SILL PAN FLASHING weather resistive barrier NTS (ol2tiona wall sheathing C Prepared b� 50AP Firet Coa6t Chapter LAJ o SHEET NO.: A-2 t ELECTRICAL LEGEND ALTERATION WORK =Oz 110 VOLT DUPLEX OUTLET—WALL MOUNTED SITE ADDRESS: 110 VOLT DUPLEX OUTLET—GROUND FAULT INTERUPT 1665 SELVA MARINA DR 77 TELEPHONE OUTLET—WALL MOUNTED ATL. BEACH, FL 32233 DRAWN BY: _60- SWITCH -4- SWITCH—FOUR WAY CABLE TELEVISION OUTLET LIGHT FIXTURE—WALL MOUNTED LIGHT FIXTURE—CEILING RECESSED NEW FRO T ELEVATION EXHAUST FAN—CEILING MOUNTED DocuSign Envelope ID:D2D3265B-Al9A-4Cl4-8lA9-735lA56ClA9B REVISIONS STRUCTURAL ENGINEER HAS VERIFIED DESIGN CRITERIA AND IOADS THE EXISTING TRUSSES HAVE BEEN DESIGNED TO SPAN THE FULL WIDTH OF BUILDING Building Code ALL NEW HEADERS OVER 2010 Florida Building and Residential Codes WINDOWS AND DOORS TO BE(2)2x6 Wit (1) TRIMMER Code for Design Loads AND(1)KING STUD ANSI/ASCE 7-10 ROOF LOADING................................................Cd= 1.25 TOP CHORD LIVE LOAD..................................20 PSF TOP CHORD DEAD LOAD................................7 PSF BOTTOM CHORD LIVE LOAD ATTICS WITH LIMITED STORAGE...............20 PSF(PER FRC) ATTICS WITHOUT STORAGE.......................10 PSF (NON-CONCURRENT) BOTTOM CHORD DEAD LOAD........................5 PSF NEW 2x4 NO.2 SPF WIND LOADING.. EXTERIOR ...............................................Cd= 1-60 FRAMING @ MAX ASCE 7-10,3S GUST.......................................*130 MPH 16"O.C. BASIC WIND SPEED 2x6 NO.2 SYFI 24"C.C. EXPOSURE CATEGORY..................................C BUILDING CATEGORY.....................................11 2x6 NO.2 SYFI @ 24"C.C. CRICKET F] ENCLOSURE CLASSIFICATION...................... ENCLOSED BOTTOM PLATE ANCHOR INTERNAL PRESSURE COEFF........................0.18 411 BACH SIDE OF NEW DOOR 41' @ EXTERIOR WAL L - WINDOW AND DOOR DESIGN WIND LOAD=+22/-29 PSF W VINYL SOFFIT DESIGN WIND LOAD=+22/-29 PSF 2x8 F IDGE (2)2�12 NO.2 SYP(UPI TABLE 4: NAIL SIZE LEGEND L NOTES 1,2,3,4 1 1[ DIAMETER LENGTH-] 0- 2x4 NO.2 SYP < 8d COMMON 0.131" 2-Y211 EXISTIING WALL LJ < I m SUFFICES. NO N COLLAR TIES yll '9 8d RINGSHANK 0.11311 2- 8 7' M @ 24"O.C. III ADDITIONAL STUDS 1 Od x 1-Y2" 0.148" 17)2 REQUIRED 10d 0.131" 311 10d COMMON 0.148" 3" 12d COMMON 0.148" 3-/V411 16d SINKER 0.148" 3-Y411 16d COMMON 0.162" 3-;/2't REMOVE 411 NOTES: 1. INSTALL 10d NAILS UNLESS OTHERWISE SPECIFIED. 0 411 EXISTING CRICKET 2. COMMON WIRE NAILS AND THREADED HARDENED STEEL NAILS NON LOAD SHALL CONFORM TO THE NOMINAL SIZES SPECIFIED IN ASTM H BEARING F1667. NOMINAL DIAMETER SIZES APPLY TO FASTENERS SOFFIT BEFORE APPLICATION OF PROTECTIVE COATING. 3. WHEN A BORED HOLE IS REQUIRED TO PREVENT SPLITTING OF A WOOD DUE TO FASTENER PENETRATION,THE BORED HOLE (D SHALL NOT EXCEED 75%OF THE NAIL OR SPIKE DIAMETER. ROOF FRAMING NOTES: 4. THE NOMINAL DIAMETER AND LENGTH OF TYPICAL FASTENERS SPECIFIED FOR THIS PROJECT ARE AS LISTED IN TABLE 4. U) fn 1. RAFTER TO RIDGE W. MIN LU _(3)10d 0 2.CEILING JOIST TO RAFTER z U) W/MIN(3)10d GENERAL STRUCTURAL NOTES F-y-I\T 3.COLLAR TIES W M IN(4) 1 Od 0 dAT EACH END 1. FASTEN ALL MULTI-PLY STUD COLUMNS UNDER B EAMS/G I RD ERS WJ(2)ROWS I Od CO M M ON @ 8"O.C.STAGGERED < 2. ALL LUMBER SPECIFIED ON DRAWINGS IS INTENDED FOR DRY USE FOR THE INTENDED LIFE OF THIS STRUCTURE, Uj UNO. ALL WATERPROOFING AND FIRE SAFETY SYSTEMS ARE THE RESPONSIBILITY OF THE CONTRACTOR AND ARE TO BE DESIGNED AND DETAILED BY OTHER. 3. ALL METAL CONNECTORS SPECIFIED ON PLAN ARE IN ADDITION TO FRAMING FASTENER REQUIREMENTS LISTED IN FLORIDA BUILDING CODE TABLE 2306.1 w > Uj Uj NEW CEILING FRAMING . NEW STR,, UCTURAL PLAN MIN OSB W/8d RING 16 SHANK: 6"O.C.AT EDGES, 12"O.C. IN FIELD MIN 1-5"CATEGORY OSBW/8d tAk 32 t COMMON: 6"O.C.AT VERTICAL EDGES AND PLATES,6"O.C. IN FIELD HEADER TO TOP PLATE W/ 2x RAFTER MAX 24" 14 z O.C. SDWC15600 SCREW OR EQUAL @ MAX 24"O.C. MIN-1"OSB W/8d RING C-1-1-1 _.�ERFRAMING 16 SHANK: 6"O.C.AT EDGES, 12"O.C. IN FIELD Z'� i4 REMOVE 2!.S EXISTING fa-4 z TOP OF EXISTING NOTE: �ML UPLIFT WALL TRUSS TO TOP PLATE CODE APPROVED w�p CONNECTtOR LOAD PATH 2K W/SDWC 15600 OR VINYL SOFFIT STOPS B�LOW TOP PLATE Zy START OSB AT F DBL TOP H2.5A/T PLATE W//MIN 48" KNEEWALL SILL TO HEADQR CONNECTION. j LAP SPLICE. (2)ROWS 10d PLATE AS SHOWN KNEEWALL TO TOP PLATE TO HEADER W/ FACE NAILS @ 8"O.C. EXISTING W/ W/ SDWC 15600 SCREW OR STAGGER ROWS SDWC 15450 SCREW @ EQUAL @MAX 24"O.C. MAX48"O.C. (2)2x6 HEADER SHEET NO.: S_1 STRUCTURAL PLAN EXISTING AND DETAILS EXTERIOR WALL CONTINUOUSLY SHEATH W/ ,it f? MIN 1-5"CATEGORY OSB W/ SITE ADDRESS: 32 8d COMMON: 6"O.C.AT DT BOTTOM PLATE VERTICAL EDGES AND 1665 SELVA MARINA DR PLATES,6"O.C. IN FIELD SIMILAR AT ATL. BEACH, FL 32233 WINDOW EXPANSION JOINT DRAWN BY: - - - - - - MATERIAL JPA I _F1__F MIN 3-1/2"INTO mm 4. EXISTING -3000 PSI CONCRETE JEFFREY P. ARNESON, P.E. STRUCTURAL ENGINEER TOPPING OVER EXISTINGb;z EXISTING EXISTING 2999 GERONA DR. W. xx JACKSONVILLE, FL 32246 C3 w f C3 M i- r_1 C'3-A r-M 1 t I #sit DIA.36 THREADED ROD A 44 'd J" W/NUT AND WASHER IN P. 4* EXISTING SLAB ADHESIVE OR EPDXY 4k 'e E�/"�0. AND FOOTING ANCHOR @ MAX 48"O.C. 00 BOTTOM PLATE ANCHOR No 58544 AIR Wit NUT AND WASHER @ 0 614D826EB43?.%"%� MAX 48"O.C. iDN 0 A rIV6% STATE OF 4U TYPICAL WALL F ME AT WINDOW WALLS SECTION THRU ADDITION 00 �N R 02 N "9/ONAk- 'E. P.E. NO. 5B544 06-09-2014