Loading...
1839 Ocean Grove Dr 2014 HVAC ?S�•�.►`1 rl�� �� � � �'• , CITY OF ATLANTIC BEACH J 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 C Application Number . . . . . 14-00001062 Date 7/07/14 Property Address . . . . . . 1839 OCEAN GROVE DR Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . RES GEN 2F DISTRICT Application valuation . . . . 0 ------------------------------------------- Application desc 1 cu 1 ahu 1 . 5 tons -------------------------------------------- Owner Contractor - ------------------------ ----------------------- NEVILLE, CYNTHIA E DONOVAN HEATING & AIR ANDERSON MARK B 315 SIXTH AVENUE SOUTH 1839 OCEAN GROVE DR JACKSONVILLE BEACH FL 32250 ATLANTIC BEACH FL 32233 (904) 241-3785 -------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . . 00 Permit Fee . . . . 87 . 00 Plan Check Fee Issue Date . . . . Valuation . . . . 0 Expiration Date . . 1/03/15 ------------------------------------------- Special Notes and Comments STICKER FOR OVERCURRENT PROTECTION MUST BE ON A/C EQUIPMENT PRIOR TO INSPECTION. FAILURE TO COMPLY WILL RESULT IN A FAILED INSPECTION AND REINSPECT FEES . NO EXCEPTIONS . ----------------------------- Other Fees . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- -- Permit Fee Total 87 . 00 87 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 91 . 00 91 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 lOB ADDRESS: �3� PERMIT# PROJECT VALUE $ "6500 ov ARI# 371-7 2 IS REQUIRED Air Handling Equipment Only � Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity ( Tons Per Unit 1 .5 15 Heat: Unit Quantity l BTU's Per Unit 06 Seer Rating REQUIRED Duct Systems: Total CFM FIRE PREVENTION Quantity (Requires 3 sets of plans) Fire Sprinkler System ( q (Requires 3 sets of plans) Fire Standpipe QuantityReuires 3 sets of plans) Underground Fire Main Value (Requires Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read its application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. , n d Phone Number -75'<' 2 6Z® Property Owners NameMn � �� a`1►3�1�S Mechanical Company 'JDYll3�4jj �ea} ' j-AI Office Phone 211 31 9f Fa x Co. Address: Oils p-� A� City 'C"AX State ZipFi 32fo License Holder(Print): State Certification/Registration# Hca 3474 1 Notarized Signature of License Holder ... - RICHARD TOMPKINS Before me this day of L/� O--L---- Commission#FF 040399 Expires July 29,2017 Signature of Notary Public t z jR ?;�`` gilded r.h%'Fein INUUM W"85-7919 �U , n Date: July 1,2014 wrVtso 87 Entire Hou •VAN By: Aaron Thacker j HEAT&AIR 7 CACO 39761 Donovan He 904/241-3785 //��((�� ,,��jj��`` Fax 241-3745 315 6th Ave SCJack 0nnvifreB�a�ch�, FL 32250 Phone 904-241-3785 Fax:904-241-3745 Email aaron�donwanaacom Web:www.Donovanx 24 AAL lal� A L�� 1..�_�—E._.II_ Pf���- ACA For: Mark Anderson 1839 Ocean Grove Dr, Atlantic Beach, FL 32233 Notes: Design Information Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 99 °F Inside db 70 °F Inside db 75 'F Design TD 31 °F Design TD 24 °F Daily range L Relative humidity 50 Moisture difference 69 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 10302 Btuh Structure 12830 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 10302 Btuh Use manufacturer's data n Rate/swing multiplier 1.04 Infiltration Equipment sensible load 13344 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average 1327 Btuh Fireplaces 0 Structure Ducts 0 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft2) 589 589 Equipment latent load 1327 Btuh Volume (ft3) 5301 5301 Air changes/hour 0.61 0.32 Equipment total load 14670 Btuh Equiv.AVF (cfm) 54 28 Req. total capacity at 0.75 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make Tempstar Make Tempstar Trade 13 SEER N SERIES R41 OA HP Trade 13 SEER R N KERIES R41 OA HP Model N4H318A(G)KE' Coil N4H318 (G) AHRI ref no3717215 Coil ref noFXM4 5 Efficiency 8.2 HSPF Efficiency 12.0 EER, 15 SEER Heating input Sensible cooling 13350 Btuh Heating output 17200 Btuh @ 47°F Latent cooling 4450 Btuh Temperature rise 26 °F Total cooling 17800 Btuh Actual air flow 593 cfm Actual air flow 593 cfm Air flow factor 0.058 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.91 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2014-Jul-01 21:58:23 _ + wrightsoft Right-Suite®Universal 8.0 24 RSU05995 Page 1 c:\Users\Owner\Documents\Wrightsoft HVAC\Bogus 1.5 ton rup Calc=MJ8 Front Door faces: S www.donovanac.com