1809 Live Oak Ln 2014 HVAC CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 14-00001103 Date 7/10/14
Property Address . . . . . . 1809 LIVE OAK LN
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . TO BE UPDATED
Application valuation . . . . 0 --------------
--------------------------------------------------------------
Application desc
1 cu 1 ahu
------------------------------------
Owner Contractor
------------------------
SNYDER HEATING & AIR
BREWTON EDWARD A. A. P.O. BOX 16826
1809 LIVE OAK LANE FL 32245
ATLANTIC BEACH FL 32233 JACKSONVILLE
(904) 325-9979
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc - - 115 . 00 Plan Check Fee . 00
Permit Fee . . . . Valuation . . . . 0
Issue Date . . . .
Expiration Date . . 1/06/15 -----------------------
-------------------------------------------- -------
Special Notes and Comments
STICKER FOR OVERCURRENT PROTECTION MUST
BE ON A/C EQUIPMENT PRIOR TO
INSPECTION. FAILURE TO COMPLY WILL
RESULT IN A FAILED INSPECTION AND
REINSPECT FEES . NO EXCEPTIONS . ---------------
---------- --------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
---------- ------- ---------------------------------------------------------
Fee summary Charged Paid Credited- Due---
----- ----------- ---------- ---- -------- ---
Permit Fee Total 115 . 00 115 . 00 . 00 . 00
Plan Check Total . 00 * 00 . 00 . 00
other Fee Total 4 . 00 4 ' 00 . 00 . 00
Grand Total 119 . 00 119 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITV' OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904) 247-5826 Fax (904) 247-5845
JOBADDRESS: LAV, (3c.-V— L, PERMIT #
PROJECT VALUE S ARI# REQUIRED
Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity t_ Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Ratina
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity I Tons Per Unit 5-ial-I
Heat: Unit Quantity I BTU's Per Unit L000ao Seer Rating V�
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
A,LL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
0THER:
lermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
his application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
iot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name E�W."r-A Phone Number 7,4-4--0?-/�' I
�4echanical Company 5,Ld, —Office Phone WI-0toWax (sq/'2-57-9
Zo. Address: ?-0. 9—Coc \S017,10 City It e State �-L Zip S'LlxW-
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph (904) 247-5826 Fax (904) 247-5845
JOBADDRESS: \-6Q)R PERMIT #
License Holder (Print): ta Certification/Registration#
Votarized Signature of License Holder
HMY K FOUST Before me this day of 20
MY COMMISSION#EE 204856 Signature of Notary Public
EXPIRES:July 21,2016
Bonded Thru Budget Notary Servkes
wv*
FThis combination qualifies for a Federal Energily
1 A KJ120 Efficiency Tax Credit when placed in service
#%a voila CERTIFIE between Feb 17, 2009 and Dec 31, 2013.
Lwww.ahridirectory.org
Certificate of Product Ratings
AHRI Certified Reference Number: 4431563 Date: 7/9/2014
-Air-Source
Product: Split System: Heat Pump with Remote Outdoor Unit
Outdoor Unit Model Number: ASZ140601A*
Indoor Unit Model Number: CA*F4961*6D*+MBVC2000**-lA*+TXV
Manufacturer: AMANA HEATING AND AIR CONDITIONING
Trade/Brand name: AMANA
Series name: ASZ14
Manufacturer responsible for the rating of this system combination is AMANA HEATING AND AIR
CONDITIONING
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
party testing:
Cooling Capacity(Btuh): 56500
EER Rating (Cooling): 12.50
SEER Rating (Cooling): 15.00
Heating Capacity(Btuh)@ 47 F: 57000
Region IV HSPF Rating (Heating): 9.00
Heating Capacity(Btuh)@ 17 F: 33000
Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate.
DISCLAIMER no representations,warranties or guarantees as to,and assumes no responsibility for,
AHRI does not endorse the product(s)listed on this Certificate and makes
the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s).orthe
s listed in the
unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configuration
directory at !z__
TERMS AND CONDITIONS HRL This Certificate shall only be used for individual,personal an d
This Certificate and its contents are proprietary products of A ,imated; 04b"Ift
confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied:dissenr idual,
entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's indiv AIR-CONDINONING,HEATINO�
personal and confidential reference. &REFRIGERATION INSTITUTE
CERTIFICATE VERIFICATION click on �irity Gertiticate,link
The information for the model cited on this certificate can be verified at
and enter the AHRI Certified Reference Number and the date on which the certificate was issued,
which is listed above,and the Certificate No.,which is listed at bottom right. CERTIFICATE NO.: 1304"117318559043
@20:14 Air-Conditioning, Heat ing,and Refrigeration Institute