Loading...
1021 Atlantic Blvd unit # 979 & 983 Sola Salon remodel MNIMMN�NNNNM � '' i e i3wx O CERTIFIED BY: SL- FL-ATLANTI (".'.'#' VILLAGE W 1021 ATLANTIC ' BOULEVARD I �,�E SU TE 19/21 �Q " o. 60531 ATLANTIC BEA(.`#* H , FLORIDA 32233 - �� STATE OF IIII - DRAWN BY: KEVIN Genera! Project Notes : 1. UNLESS OTHERWISE INDICATED, GENERAL NOTES APPLY TO ALL DRAWINGS IN THIS SET. pr 2. THESE DRAWINGS AND COPIES THEREOF ARE LEGAL INSTRUMENTS OF SERVICE FOR USE OF THE OWNER ONLY. ' r L ,` N 3. ANY DEVIATIONS FROM THE CONTRACT DOCUMENTS WHICH ARE NECESSITATED BY FIELD CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER. W f- M LISTOF ABBREVIATIONS DRAWING INDEX P R OJ ECT TEAM 4. UNLESS OTHERWISE NOTED,ALL DIMENSIONS ARE TAKEN FROM BUILDING LINES, FACE OF STUD WALLS, FACE OF MASONRY, CENTERLINES, BACK OF CURBS, OR AT OTHER LOCATIONS AS INDICATED. W U) M 5. WALL TYPES ARE DESIGNATED ON THE FLOOR PLAN. U- AFF ABOVE FINISHED FLOOR � -_i > _ 6. ALL WALLS SHALL EXTEND 6"ABOVE DESIGNATED CEILING HEIGHT UNLESS NOTED OTHERWISE. > W V AHU AIR HANDLER UNIT CS 1 .0 COVER SHEET/DRAWING INDEX !' Project Owner: Four S Jacksonville, LLC a ANSI AMERICAN NATIONAL STANDARDS INSTITUTE Haynes Chidsey 7. PROVISIONS SHALL BE MADE AT ALL FULL HEIGHT NONBEARING WALL FOR 1-INCH VERTICAL MOVEMENT OF THE BUILDING STRUCTURE H m ARCH ARCHITECTURAL CS PRODUCT APPROVALS I1300 Baxter St. Ste. 421 WITHOUT TRANSFER OF COMPRESSIVE LOADS TO WALL. FILL IRREGULARITIES BETWEEN TOP OF WALL AND DECK ABOVE WITH FIRE 0 Q in V • SAFING INSULATION OR FIRE STOPPING MATE^!ALS AS REQUIRED TO MEET FIRE RATING OF RESPECTIVE WALLS. (� J U �- BLDG BUILDING Charlotte NC 28204 i., z CATV CABLE TELEVISION I I Tel: 704.900.7730 8. ALL PENETRATIONS THROUGH RATED DEMISING WALLS SHALL BE SEALED WITH FIRE STOPPING MATERIAL AS REQUIRED TO ACHIEVE Q Z Q CLG CEILING CS 1 .2- PRODUCT APPROVALS THE RESPECTIVE FIRE-RESISTIVE RATING AND SMOKE STOPPAGE. Q J Cell: 303.881 .7314 i H a CLR CLEAR CS 1 .3 PRODUCT I 9. THE GENERAL CONTRACTOR SHALL FURNISH AND INSTALL WOOD BLOCKING IN WALL PARTITIONS FOR THE PROPER ANCHORAGE OF Q APPROVAL ALL WALL ATTACHED ITEMS: I.E. TOILET ACCESSORIES, CABINETS, WALL-MOUNTED FIXTURES, CASEWORK, MILLWORK, ETC. r CONC CONCRETE Design Team: KDC Condulting Inc. � N CONST CONSTRUCTION A1 . 1 FLOOR PLAN/DETAILS Kevin D. Conrad 10. GYPSUM BOARD SURFACES SHALL BE ISOLATED WITH CONTROL JOINTS AS PER MANUFACTURERS REQUIREMENTS AND INDUSTRY CONTR CONTRACTORMatthew D. Holbrook, Professional Engineer STANDARDS. ALL GYPSUM BOARD SURFACES ARE TO BE FINISHED SMOOTH.1 GYPSUM ASSOCIATION GA-214-96 LEVEL 4 FINISH, WITH 3520 S. 450 E. THE FOLLOWING ADDITION;ANY READILY VISIBLE IMPERFECTIONS IN GYPSUM BOARD SURFACE SHALL BE COATED WITH JOINT CT CERAMIC TILE A1 .2 FIXTURE PLAN S C H E D LES COMPOUND AND/OR SKIM-COATED AS REQUIRED. DF DRINKING FOUNTAIN / Anderson, IN 46017 DIM DIMENSION /� 1 .3 FINISH N I S H PLAN/S C H E D U L S Tel: 317.501 .3544 11. THE GENERAL CONTRACTOR SHALL INCLUDE ALL OWNER FURNISHED AND INSTALLED ITEMS AND OWNER FURNISHED AND CONTRACTOR DISP DISPENSARY INSTALLED ITEMS IN THE CONSTRUCTION,AND SHALL COORDINATE WITH THE OWNER TO ACCOMMODATE THESE ITEMS. EDF EXISTING DRINKING FOUNTAIN General Contractor: Jansen Gehring A1 .4 12. THE GENERAL CONTRACTOR SHALL VISIT PROJECT SITE PRIOR TO SUBMITTAL OF BID. CONTRACTOR SHALL ESTABLISH SCOPE OF WORK DETAILS, Tel: 317.259.7000 FROM CONSTRUCTION DOCUMENTS AND ACTUAL PROJECT SITE VISIT.ANY OMISSIONS, DISCREPANCIES OR CLARIFICATIONS ARE TO BE EEP EXISTING ELECTRICAL PANEL BROUGHT TO THE IMMEDIATE ATTENTIONS OF THE SYMPATECO, INC.AND OWNER. FAILURE OF CONTRACTOR TO PERFORM IN THIS MANNER A 1 .5 ELECTRICAL LAYOUT DETAILS I LS DOES NOT ALLOW FOR ADDITIONAL COST TO THE OWNER. FD FLOOR DRAIN Specialty Casework: SYMPATECO, INC. :K;. EFD EXISTING FLOOR DRAIN - 11625 1 St. 13. THE GENERAL CONTRACTOR SHALL PROVIDE DUST PARTITIONS AS NECESSARY TO CLOSE OFF AREA OF WORK FROM ACTIVE AREAS OF THE r C 0 FLUOR FLUORESCENT A1 .6 REFLECTED CEILING P AN Omaha, NE 68137 BUILDING. FILL r GC GENERAL CONTRACTOR Deb Spaeth 14. THE GENERAL CONTRACTOR SHALL PROVIDE SECURITY PARTITIONS AS NECESSARY TO SECURE AREAS OF THE BUILDING FROM GWB GYPSUM WALL BOARD A � . � PLUMBING LAYOUT & DETAILS Gillian Nassie UNAUTHORIZED ENTRY. GYP GYPSUM Tel: 800.652.1923 15. ALL CONTRACTORS INVOLVED IN THIS PROJECT SHALL REVIEW ALL DRAWINGS INCLUDED IN THIS DRAWING SET AND SHALL COORDINATE , HC HANDICAP (ED) Fax: 402.333.6481 THEIR WORK WITH OTHER TRADES ON THIS PROJECT. ` HVAC HEATING/VENTILATING/AIR CONDITIONING E1 . 1 ELECTRICAL SPECIFICATIONS INSUL INSULATION 16. THE GENERAL CONTRACTOR SHALL REPAIR ALL AREAS DAMAGED OR MODIFIED AS THE RESULT OF CONSTRUCTION ACTIVITIES. INT INTERIOR E1 •2 ELECTRICAL POWER PLAN 17. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR GENERATING THE CONSTRUCTION SCHEDULE AND ADHERING TO SUCH LAV LAVATORY SCHEDULE AFTER APPROVAL BY THE OWNER. I! ; LOC LOCATION (S) - MAX MAXIMUM E 1 .3 ELECTRICAL POWER PLAN - ROOF 18. GENERAL CONTRACTOR SHALL COORDINATE WITH MECHANICAL AND ELECTRICAL CONTRACTORS FOR ADDITIONAL REQUIRED EQUIPMENT AND SIZING.THIS WOULD INCLUDE ALL HVAC AND ELECTRICAL. MIN MINIMUM El .4 ELECTRICAL LIGHTING PLAN APPLICABLE CODES x TUD=o. NIC NOT IN CONTRACT i 19. THE GENERAL CONTRACTOR SHALL ADHERE TO REQUIREMENTS OF SPECIFICATIONS FOR BUILDING SHELL PACKAGE.TO ENSURE NTS NOT TO SCALE CONSISTENCY IN MATERIALS AND WORKMANSHIP. OC ON CENTER M1 . 1 MECHANICAL PLAN BUILDING CODE: 20. ALL WORK SHALL CONFORM TO THE REQUIREMENTS WITHIN THE CURRENT EDITIONS OF ALL LOCAL, CITY, STATE AND FEDERAL APPLICABLE OPNG OPENING 2010 FLORIDA BUILDING CODE CODES ADOPTED BY THE LOCAL JURISDICTION. M 12 MECHANICAL • PLAM PLASTIC LAMINATE PLAN - ROOF PLUMBING CODE. 21. SCOPE OF PROFESSIONAL SERVICES IS LIMITED TO THE TENANT IMPROVEMENT,AND DOES NOT ADDRESS THE BUILDING SHELL ELEMENTS, PLBG PLUMBING 2010 FLORIDA PLUMBING CODE ROOF ASSEMBLY,WALL ASSEMBLY, FLOOR ASSEMBLY. ALL PENETRATIONS, INFILL AND ASSOCIATED DETAILING IS THE RESPONSIBILITY OF PLYWD PLYWOOD P1 . 1 PLUMBING PLAN - WA TE THE CONTRACTOR OR OTHERS. REQ REQUIRED (REQUIREMENTS) ELECTRICAL CODE: ` i'; €.=C 22. EACH TRADE SHALL BE HELD RESPONSIBLE FOR KNOWLEDGE OF THE GENERAL NOTES INCLUDED THROUGHOUT THE CONTRACT HAYNES CHIDSEY RM ROOM P 1 .2 PLUMBING PLAN - WATER ,,,,� �`'�� '� ' OWNER NFPA 70 DOCUMENTS AND THE APPLICABLE BUILDING CODES. SI SYMPATECO, INC. �`� P 1 .3 PLUMBING RISER DIAGRAMS , "? 23. NOTED DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS, DO NOT SCALE DRAWINGS. BUS.: 704.900.7730 . TYP TYPICAL 0 OCFLOR FLORIDADA MECHANICAL CODE VAC VACUUM CEL.: 303.881 .7314 VTR VENT THROUGH ROOF ; r � ����, ,�.��,,, 24. IN THE EVENT DISCREPANCIES OR CONFLICTS ARISE AMONG DRAWINGS AND/OR OTHER DESCRIPTIONS CONTAINED HEREIN,THE LS1 . l LIFE SAFETY PLAN FIRE/ LIFE SAFETY CODE: 1 ` - }°1r} ¢�'§IS ''' CONTRACTOR SHALL NOTIFY SYMPATECO IMMEDIATELY FOR CLARIFICATION. `y I r s ........w. .».... �.. ..�. 2010 FLORIDA FIRE CODE 1` 25. THE GENERAL CONTRACTOR MUST VERIFY AND COORDINATE ALL OPERATIONAL REQUIREMENTS AND CLEARANCE DIMENSIONS OF "�, � t PROJECT COMPONENTS; INCLUDING CONTRACTOR SUPPLIED AND OWNER SUPPLIED ITEMS. THIS INCLUDES BUT IS NOT LIMITED TO THE CITI .' .i a -: - ACCESSIBILITY CODE: FUNCTIONAL ASPECTS OF THE FOLLOWING: SEE Li; 2010 FLORIDA BUILDING CODE EQLI A) APPLIANCE, DISHWASHER, REFRIGERATOR,WASHER, DRYER, MICROWAVE, DISPOSAL, ETC. (I.E., DOOR OPERATION CLEARS ALL . ENERGY CODE: DOOR TRIM, CASED OPENING TRIM AND WALL MOUNTED ITEMS). _? � � FLORIDA ENERGY CODE FLCCSB v.4.0 B) ELECTRONIC DEVICES, COPIER, FAX MACHINE, COMPUTER,TELEVISION, VCR, DVD PLAYER, SOUND COMPONENTS, ETC. - -- PROJECT: GAS CODE: C) CABINETRY, HARDWARE, PULLS, SLIDES, ETC. COORDINATE AND ENSURE PRT: COMPLETE FREE AND CLEAR OPERATION OF DRAWERS ` - SLOJEC 3 2010 FLORIDA FUEL GAS CODE) AND DOORS. PROVIDE A 11/2 SCRIBE AT THE ENDS OF ALL CABINET RUNS ABUTTING ADJACENT WALL ASSEMBLIES TO ENSURE ADEQUATE CLEARANCES. ATLANTIC VILLAGE CONSTRUCTION TYPE CLASSIFICATION: 26. THE GENERAL CONTRACTOR SHALL ITEMIZE ALL COSTS AND SCOPE OF WORK REGARDING ANY CHANGE ORDER. THIS INFORMATION MUST RELEASE DATE TYPE II-B-SPRINKLED BE PRESENTED TO THE OWNER FOR APPROVAL PRIOR TO ANY WORK BEING EXECUTED. 27. ALL LIGHT FIXTURES THAT COME INTO CONTACT WITH BUILDING INSULATION MUST BE IC RATED. ALL LIGHT FIXTURES SHALL MEET ALL 04/02/14 APPLICABLE CODES FROM NATIONAL ELECTRIC CODE (NEC) TO THE INTERNATIONAL ENERGY CODE (IEC). CONTRACTOR IS TO VERIFY CODE REVISIONS: COMPLIANCE OF ALL LIGHT FIXTURES. 1 BLDG. DEPT. REVIEW-5/23/2014 28. GENERAL CONTRACTOR SHALL COORDINATE ALL MECHANICAL CHASE SIZES WITH THE MECHANICAL CONTRACTOR. 29. ALL ELECTRICAL SWITCHING TO BE LOCATED AT OPERABLE SIDE OF DOOR OPENINGS AND AS SHOWN ON THE PLANS. THIS INCLUDES SWITCHED OUTLETS AND LIGHT FIXTURES. ITEMS SUCH AS GARBAGE DISPOSAL LOCATED PER PLANS. ANY DEVIATION IS TO BE BROUGHT TO THE ATTENTION OF THE OWNER AND SYMPAETCO, INC. FOR CLARIFICATION. 30. ANY SHUT DOWN OF THE FIRE PROTECTION SYSTEM WILL REQUIRE NOTICE TO ALL OTHER TENANTS WITHIN THE SYSTEM AND SHALL BE COORDINATED WITH THE LANDLORD. 31. IF A CONFLICT/DISCREPANCIES OCCUR BETWEEN THE DESIGN DRAWINGS, ENGINEER DRAWINGS AND/OR SPECIFICATIONS,THE MORE DRAWING NAME STRINGENT&EXPENSIVE OPTION SHALL BE PERFORMED BY THE CONTRACTOR. COVER SHEET/INDEX SHEET NO. FILEIi r CS1 . 0 I ----._-- .__ _.___-:. .. ... .,.:. s ,_ .. �• _..-'. >_. it-_., -. r � 3 U z C� -- _- -- z PRODUCT APPROVAL FOR SERIES FG-2000 STOREFRONT HIGH A. S.D. DESIGN PRESSURE � J 1P � iE�IT F� R ERE - CCC TC� E �C� T W NON IMPACT h�ONOLITHIC TEMPERED CLA55 co GENERAL NOTES: zWE 1. SERIES FG-2040 STOREFRONT HIGH DESIGN PRESSURE W/ NON IMPACT MONOLITHIC TEMPERED GLASS. SHOWN 1,3, PRODUCT MANUFACTURER'S !.ABEL SHALL BE LOCATED ON A READILY VISIBLE LOCATION SCALE:3!8 1"' O ON THIS PRODUCT EVALUATION DOCUMENT (P,E,D) HAS BEEN VERIFIED FOR COMPLIANCE IN ACCORDANCE Wj AT PRODUCT IN ACCORDANCE WITH SECTION 1715.5 OF THE FLORIDA BUILDING CODE. 2010 EDITION OF THE FLORIDA BUILDING CODE, THIS PRODUCT MAY BE INSTALLED WITHIN HIGH & NON HIGH ONE LABEL SHALL BE PLACED FOR EVERY OPENING. ♦ ♦ 910 VELOCITY HURRICANE ZONES W/ LIMITATIONS AS. PER NOTE 3 BELOW. �•! Oj DESIGN WIND LOADS SHALL BE DETERMINED AS PER SECTIONS 1620 (FOR HIGH VELOCITY HURRICANE ZONES) 8c •375" _ I 1609 (FOR NON HIGH VELOCITY HURRICANE ZONES) OF THE ABOVE MENTIONED CODE. 495 _.5" FOR A BASIC WIND SPEED AS REQUIRED BY THE JURISDICTION WHERE THIS PRODUCT WILL BE INSTALLED _ •078" 4�8„ 063" 1.750" .494"- FOR A DIRECTIONALITY f ACTOR Kd=0.85. USING ASCE 7-10 FOR INSTALLATIONS UNDER 2010 FBC 25" 594" 4„ 620"+ ; °,Q7q" (Typ.) 734" ! 1,754" " AND SHALT_ NOT EXCEED THE MAXIMUM (A.5,D,) DESIGN PRESSURE RATINGS INDICATED ON NOTE 2. SHEET 1. GENERAL NOTES, INDEX AND INSTRUGTIOPJS. .25 _-- } I 730 .641 IN ORDER TO VERIFY THE ABOVE CONDITION, ULTIMATE DESIGN WIND LOADS DETERMINED PER ASCE 7-10 �I F j __- 736" ( 4.004"- w_��} „ (Typ•) SHALL BE FIRST REDUCED TO ?,:S.D, DESIGN WIND LOADS BY MULTIPLYING THEM BY 0.6 IN ORDER TO SHEET 2: COMPONENTS FOR SERIES FG-2000 STOREFRONT. 1,4g� •125 .096 CERTIFIED BY: TO COMPARE THESE W/ MAX. (A,S.D) DESIGN PRESSURE RATINGS INDICATED ON NOTE 2. SHEET 3; BILL OF MATERIALS, TYPICAL GLAZING DETAIL & MAXIMUM A.S.D. DESIGN 1 G ZING GASKET 2 SETTING BLOCK SILL FILLER PRESSURE RATING SCHEDULE FOR A GIVEN GLASS PANEL DIMENSIONS. JAMB MULLION MULLION FILLER IN ORDER TO VERIFY THAT ANCHORS ON THIS P,E.D., AS TESTED, WERE NOT OVERSTRESSED, A 33 INCREASE IN FC-1133 �C- 1 136 ILL FILLER ALLOWABLE STRESS FOR WIND LOADS WAS USED IN THEIR ANALYSIS. FASTENERS SPACING TO WOOD HAS FG-210{ FG 2101 FG-2102 BEEN DETERMINED IN ACCORDANCE WITH N,D,S, 2005 OR AVAILABLE TEST DATA FROM MANUFACTURER. SHEET 4; ELEVATION FOR SERIES FG-2000 STOREFRONT. \\��111111l11/!!! THIS PRODUCT'S ADEQUACY FOR WIND RESISTANCE -HAS BEEN VERIFIED IN ACCORDANCE WITH SECTIONS 1625 SHEET 5: MAXIMUM A.S.D. DESIGN PRESSURE RATING FOR MULLIONS, (EXCEPT 1625,4) & 1714,5,3 OF THE ABOVE MENTIONED CODE AS PER PROTOCOL TAS-202 AND ASTM E330, , �\ �� ..10EN. PER ARCHITECTURAL TESTING, INC. LABORATORY REPORT # 99493,01-801-44 AND. AS PER STRUCTURAL SHEET 6; SILL OR HEAD CONNECTIONS DETAILS (PLAN VIEWS) AND MAXIM M A,S.D. DESIGN \ 3F •;Q� ' CALCULATIONS, PERFORMED AS PER SECTIONS 1604 & 1612 OF THE FLORIDA BUILDING CODE. PRESSURE RATING SCHEDULE FOR MULLIONS W/ HEAD/SILL CO NECTIONS. ',.' 2, MAXIMUM A,S.D. DESIGN R 55URE RATING FOR THi P 0 U T SH&L BE A SHOWN ON BEETS 3 5 6 & 7 SHEET 7: MAXIMUM A.S.D. DESIGN PRESSURE RATING FOR HORIZONTAL, No. 60531 �� 1.937 -� l'L1 3. -PRODUCTU V HURRICANE _R I iO DE/1 E ht E '0 T I S S1-EET 8; HEAD, HORIZONTAL & SILL CONNECTION DETAILS (SIDE VIEW), ! I- 4.500 � -4.480" -4.480" :• *= IMPACT RESISTANT IF PRODUCT IS NOT PROTECTED WITH AN APPROVED HURRICANE PROTECTIVE DEVICE ; I !' i.742" 235"' ��, S7ATE OF 11/ THEN IT SHALL BE INSTALLED OUT OF THE HIGH VELOCITY HURRICANE ZONE AND_ 1l.11_OF ANY WIND BORNE SHEET 9; SECTIvNS AT JAMES AND AT MULLIONS. ( 1,�g2 ` ! � I--a,eel' � IS REGIONS, '-1N QN 16 F `E L R! A-B D NG O a �s l �. " SHEET iu; MAXIMUM A,S,0. DESIGN PRESSURE RATING & MAXIMUM FASTENERS SPACING _ 094" rn ` 4.000"-, .,ORIpP ••G� 4, THIS PRODUCT IS APPROVED FOR 12.11 p.s f A! /WATER 'NFILTRATION, SCHEDULE FOR JAMB CONNECTION AND CORNER DETAIL. 078" �� :478" C? o �� Sz (Tye ) - 1.750" (Typ ) r I I / N 1.,753' I �TYp) 1.753" -_ ,085" I I 8'5" 875" - 1.234" 055" 990 354„ -.l a 5. TEMPERER GLASS TO COMPLY WITH SECTIONS 241 1.1,3 OF THE- FLORIDA BUILDING CODE. _ �59 � i PRODUCT SHALL COMPLY WITH SECTIONS 2446.1, 2�-11,4,1 AND 2411,4.2 OF THE FLORIDA BUILDING CODE, ,478" 6, PROVIDE 3/8" fl 1,496" 1,096" -4,000"-----^ / MAX. LOAD BEARING SHIM SPACE (TYP.), WHEN ALLOWED BY THIS DRAWING. ZD 7 HEAD & JAMB HORIZONTAL SILL 10 GLASS STOf? 11 HEAD JAMB FILLER 7. WOOD BUCKS BY OTHERS, MUST BE ANCHORED PROPERLY TO TRANSFER LOADS TO THE BUILDING STRUCTURE. -INER 005: FC-2103 FG--2104 FG-2105 FG-2166 FG-21 22 WOOD BUCKS MUST BE SOUTHERN PINE, WITH G = 0,55. DRAWN BY: 8• REMAINING COMPONENTS FOR THIS PRODUCT SHALL BE A5 INDICATED ON BILL OF MATERIALS, SHEET 3 OF THIS �. - 9: DETERMINE A,S.D. DESIGN WIND LOAD REQUIREMENTS EASED ON WIND VELOCITY, BUILDING I I DRAWING. HEIGHT, WIND ZONE, USING APPLICABLE ASCE 7 STANDARDS, KEVIN 9, ALL ALUMINUM EXTRUSIONS IN CONTACT WITH STEEL, CONCRETE AND WOOD SHALL COMPLY WITH SECTIONS : GO TO SCHEDULE ON SHEET 3 TO DETERMINE MAXIMUM A.S,D. DESIGN PRESSURE RATING 2003,8.4,2, 2003,8,4.4, 2003.8.5 AND 2003.8,6 OF THE FLORIDA BUILDING CODE, RESPECTIVELY, (psf) CAPACITY OF DESIRED GLASS SIZE BASED ON GLASS PANEL DIMENSIONS. 10, SHOP DRAWINGS PREPARED BASED ON THIS APPROVAL AND TAKING INTO ACCOUNT THE SPECIFIC JOB v 3: DETERMINE MAXIMUM MULLION SPAN "L"(FT) FOR A GIVEN MULLION EFFECTIVE CONDITIONS, SHALL BE SUBMITTED TO THE BUILDING OFFICIAL AS PART OF THE PERMIT DOCUMENTS, SPACING "b ON SCHEDULE ON SHEET 5, AND SELECT ANCHOR OPTION W/ A,S,D, 11, STRUCTURAL SUBSTRATES NOTED ON THIS .DRAWING AS EXISTING STEEL BY OTHERS, POURED CONCRETE, HOLLOW` DESIGN PRESSURE RATING EQUAL OR GREATER THAN A,S.D DESIGN WIND LOAD I .078„ ---I y3 g03 q62" BLOCK AND WOOD MUST WITHSTAND THE LOADS IMPOSED BY THIS PRODUCT, SPECIFIED IN STEP 1 USING SCHEDULE ON SHEET 6. (TYP,) II 4A88" 3,904" -} 12. (a) THIS P.E.D, PREPARED BY THIS ENGINEER IS GENERIC AND DOES" NOT PROVIDE INFORMATION FOR A SITE sTEp A. DETERMINE MAXIMUM ANCHOR SPACING AT JAMB FOR A GIVEN MAXIMUM 2.125' i 754„ , SPECIFIC PROJECT; i.e. WHERE THE SITE CONDITIONS DEVIATE FROM THE P,E.D. A.S.D. DESIGN PRESSURE RATING AND MAXIMUM MULLION SPACING, ON SHEET 1q + .231'- 162" 250" 1,092" �/ 2,125" �-� 1.254" r= u "- .188".. � 1.250" _-WEE-2 USE SCHEDULE ON SHEET 7, TO VERIFY MAXIMUM A,S.D, DESIGN PRESSURE RATING f I � (TYP,) (TYP,) � (TYP.) I (b) 0 THIS CPRODUCTBEBA,SED dNIBTHIS FP P.E.D. PROVQEDIOHE/SHE CDOES AND DT fDEJATETFRORINTHEDCONDITING IONSAFETI OF HORIZONTALS (IF USED) FOP. A GIVEN HORIZONTAL EFFECTVE "7.L,d. I.___ � •390" -�� 0 0'" -� .625" DETAILED ON THIS DOCUMENT, CONSTRUCTION SAFETY AT SITE 1S THE CONTRACTOR'S RESPONSIBILITY. f"+ 6; THE LOWEST VALUE OF A.S.D, DESIGN PRESSURE RATING RESULTIIN3 FROM STEPS 2, 3 12 S I3 SILL 1 MULLION j4 STEEL REINFORCEMENT 15 STEEL REINFORCEMENT 16 STEEL REINFORCEMENT 21 END DAM AND 5 SHALL APPLY TO THE ENTIRE SYSTEM, (c) THIS P,E,D, WILL BE CONSIDERED INVALID IF ALTERED BY ANY MEANS. F -21b FG-2228 RS- 1 RS-9 RS-10 FG-2000-FP-4 (d) SITE SPECIFIC PROJECTS SHALL BE PREPARED BY A FLORIDA REGISTERED ENGINEER DR ARCHITECT WHICH I WILL BECOME THE ENGINEER OF RECORD (E,O,R.) FOR THE PROJECT AND WHO WILL BE RESPONSIBLE FOR N O THE PROPER USE OF THE P.E.D. ENGINEER OF RECORD, ACTING AS A DELEGATED ENGINEER TO THE P.E.D. r ENGINEER, SHALL SUBMIT TO THIS LATTER THE SITE SPECIFIC DRAWINGS FOR REVIEW, W It- (e) ORIGINAL P,E,D, SHALL BEAR THE DATE AND ORIGINAL SEAL AND SIGNATURE OF THE PROFESSIONAL ENGINEER I � M OF RECORD THAT PREPARED IT. = CO) W 0) M 0 LLLL > LU Oo _ Q 1= m Z0U J U H I-- Z a Z Q FJ-- Q � Q N O r BILL OF MATERIALS --- - - - ITEM Na. PART NUMBER DESCRIPTION DIMENSIONS MATERIAL MANUFACTURER NATES ELEVATION FOR SERIES FO- 2000 STOREFRONT HIGH DESIGN PRESSURE 1. FG-1133 GLAZING GASKET _ ,525" x ,x"95" EPDM _ EPG 2, FG-1136 SETTING BLOCK 375" x .594" EPDM EPG 3, FG-2182 SILL FILLER -- --- INFINITE FRAME WIDTH =- 4.00" x 4.00" x .078" B+J63-T6 ALUMINUM VARIES LOCATED CENTER WITH ANCHORS LOCA CION DOOR & DOOR JAMB MULLION 4. FG-2100 JAMB 5, FG-2101 MULLION --- _- 4.50 x 1,7513 x .078 601;3-T6 ALUMINUM OBE 3/8' MAX.- 4.50" „ " " -. -- _ x 1.750" x .094" 6063-T6 ALUMINUM OBE SHIM SPACE 6: FG-2102 MULLION FILLER 4.00" x .641" x .0178" 6063-T6 ALUMINUM OBE (Typ•) _ i I 7, FG-2103 HEAD & JAMB „ „ W -- I Y� TING 1 1A 1B � i 1A 1B - 4.50 x_1,75 x .078 6063-T6 ALUMINUM QBE - STRUCTURE L__�'.� 8, FG-2104 HORIZONTAL y- LY Y FASTENERS 4.515" x .1.7'53" x ,094" BO63=-T6 ALUMINUM OBE _ •. 9, FG-2105 SILL_ " „ - ----- 4.480 x 1,753" x .078 8063_--aa ALUMINUM OBE _____ /_ ! •j---•--�----- I 10: FG-2166 GLASS STOP - „ 1,9 x 8 -T ( I 37 1363 5 ALU c 1,234 x ALUMINUM NUM OBE � 8 � 11. FO 2122 HEAP & JAMB FILLER 4.00" x .354" x .078" x 4" LONG 6083-T5 ALUMINUM 013E LOCATED CENTER WITH ANCHOR'S LOCA ON °� MAX. L. - D. 0, 1 FG-2169 sua SILL 4.390" x 2.125" x :078" 6063-T5 ALUMINUM EPG s 13. FG-2228 MULLION 4 4A 6 A B -• 6 8 / 2 ( .. _ .. _ . _ 4.50" x 1.75" x ,231" 8063-T6 ALUMINUM OBE IIF8 IIT 14. RS-1 STEEL REINFORCEMENT j 4.188" zI- 1,249"x .152'° A-�36 STEEL VARIES ZINC PLAT'E'D � � T 3.903" x 1.492" x 250„ A-36 STEEL VARIES ZINC PLATED a ci INDICATES 5 t I INDICATES HORIZONTAL I l 15, RS-9 STEEL REINFORCEMENT '� " REINFORCEMENT REINFORCE UT / I 18, RS-14 _ STEEL REINFORCEMENT 3.904 x 1.250 x .188 A- 36 STEEL VARIES ZINC PLATED I I I I /y, _j FASTENERS - / i x TIIDIOi 17, 795 PERIMETER SEALANT & VINYL JOINTS ° T I i I SLLICONE DOW CORNING LOCATED AT EACH INTERIOR FRAME COR ER M a T ' MAX. D.L.O. - 1-8. FS-8 SPLINE ASSEMBLY SCREW #14 x i" HHSTS STEEL VARIES X¢ _ / I p HORIZONTAL II _I 19. FG-1(14(1-FP-i -WATER DIVERTER-SET IN SEALANT 1.187' x ,750"--x 1.3*.V _PVC OBE kJCkTED nT.EACH-END OF & Sc^Ai.EI� Wj � E i I 6 ro � I 213, SM-5601 -1SOCRYL TAPE - .125"-xHaRlzalvr g / (} = .SOA" VARIES POLYISOBUTYLENE SCtdNEE-MOOREWEAD LOCA-TED AT EACH END-OF HORIZONTAL BETWEEN JOINTS- 21, FG-2000-FP--4 END DAM �r + .625" x 2.125' x .062" 8063-T6 ALUMINUM OBE FHHRICA°i ED LENGTH 4.25" _ ��.", ! I f 22, FS-22 SCREW FOR STEEL REINFORCEMENT 12 x 1 2" PHILLIPS- FLAT HEAD STEEL, v° 10 r /% tom + I ZINC COATED VARIES STAR( _6"a,c, FROM ENbS, BALANCE_�D 12°c�.e. 1 1 -- (rm. w; 1 Srm. 23: CLOS CELL BACKER P,::C 5(10" PO4YETHYLENE VARIES (� \ . / �..� 1- I _ ,, MAXIMUM A:S,D. DESIGN PRESSURE RATCNG _.�_S SCHEDULE _DIMENSIC)NS LEGEND _n FOR A GIVEN GLASS PANEL DIMENSIONS "a" (in} x"b" (in) (SEE LEGEND) 3a HAYNES CHIDSEY „br, x/t 0 bi. „_ _ VertlCal BL OWNER GLASS TYPE Head 1 Mullion FASTENERS FASTENERS MAXIMUM B MAXIMUM MAXIMUM A,S.19 n US.. 704.900.7730 DIMENSION DIMENSION QESICN LO. (° g o o(b CEL.: 303.881 .7314 0130 � "e„ PRESSURE -� -Jamb FOOT NOTES: RATING TYPICAL GLAZING DETAIL18" (pef3 DETERMINATION OF MAXIMUM a -DLO (b from 18" to 312" �6t?.0 Jamb J � A " DAYLIGHT OPENING (Q.L.O.i FOR MAXIMUM MULLION SPACING ON CENTERS SEE SHEET 5, 24 from 24" to 234" f60.O - 30" from 30'" to 186" 160,0 AT EACH END OF GLASS �- Sill �--Horizontal 1/4" NOMINAL GIVEN "a" & "b Mullion MONOLITHIC 36" from 36" to 155" *60,0 ° „ FOR MULLIONS HEAD AND SILL FASTENERS QUANTITY, TYPES AND SPECS SEE SHEET 6, TEMPERED GLASS 42" from 42" to 132" ±60.0 �_----` '�$" from 48' to 114" X60:0 MAXIMUM DAY LIGHT OPENING ° _ -� -Head FOR JAMB FASTENERS SPACING, TYPES AND SPECS SEE SHEET 10. from 54" to 90" ±60.0 SIDE (D L 0.)Formula at (D.L.O.}Formula at EXTERIOR „ " Ver-tical Hes'2ontal Jamb,Head&sill LO (o � � USE OF HORIZONTAL {SEE SECTION 2/8) LIMITED BY SCHEDULE ON SHEET 7, a PROJECT: 54 from 54 to 9I3 t69,S Pnu!I!ons Frames � ' SL-FL-253 MAX, D.L.o, F L4 (a} ` Jamb FOR MAXIMUM MULLION SPAN SEE SHEET 5, from 54" to i02" ±68.6 ATLANTIC VILLAGE from 6O" to 84" tfit7.O (a) „Q"-3.50'r Q.,-3.54" o _J � gt3" (SHORT SIDE) � from 60" to 90" ±58.2 MAX. D.L.O. Jamb Horizontal � FOR GLAZING DETAILS AND GLASS SCHEDULE SEE SHEET 3, RELEASE DATE 5/8' Min. ���� from 66" to $4" X58 01 (LONG SIDE} „b"-3.50" "b"-3.5q" Mullion GLASS BITE LLFOR MAXIMUM D.L.O. SEE SCHEDULE ON SHEET 3, 04/02/14 SiII l- Vertical 72" from 72" to 78" t60,0 Mullion REVISIONS: 1 BLDG. DEPT. REVIEW-5/23/2014 DRAWING NAME PRODUCT APPROVALS SHEET NO. CS1 . 1 a - - Y..n.,.. a, i e.ir s. ,,.,.i. ,,.tY r r n, ";: � , I_. 1 .r r, ,.i,.t,d fi ::! r. I e,t,...,.V.,, .•,a=' in v ,., .. kar„as. -: T -- IIIYYY I II , i I �I `6 jI I IP t MAXIMUM A.S.D. DESIGN PRESSURE RATING FOR MULLIONS -1 3/4"- M-1 MULLION + M-2 MULLION OR HEAD CC)NNECTIONS DETAILSfoN + + MAXIMUM MULLION SPAN"L" FT 4 "-' SCHEDULE FOR A GIVEN A,S,D,DESIGN PRESSURE RATING �- -4" 4"- �" MULLION " PLAN VIE=WS) MAX. f- 4' 4 4' -----4 ( SHIM SPACE � i W (psf)AND A GIVEN MULLION EFFECTIVE SPACING'b"(!n) �--=3 i I ��1 MAXIMUM A.S.D, DESIGN EFFECTIVE MAXIMUM MULLION SPAN "L"(FI) _ cd w - PRESSURE SPACING RATING CASE 1 CASE 2 . CASE 3 CARE 4 CASE 5 a� I -- __ - M-3 M-4 M 5 li�it - {p (Ft Int N�-1 N1j-� _..-.. 1111 . . . I 1- 0 .ft ' 11 1 t, 1 -.-I .1 it 1.. 0 I1 ..,...... g � - 0 8 - a 8 - a 8 - a 10 - 0 �0 V n � FASTENERS I CERTIFIED BY: ; . 6 N i it 1 ti 1 n 1 w t w N 3 $ " 0 _. 8 - 0 8 - 0 110 - 0 10 - t -TON 1 it f rl 0 ❑ f tl I N t t) EXTERIOR HEJ\D OR SELL OTAL NUMBER OF FASTENERS AT JAMB LOCATION HEAD OR SILL JAMB - - - - _ - "M" FASTENERS PER CONNECTION AT HEAD/SILL SHALL BE 50% 8 � 8 �} '� {� 10 �} 1 10 0 X 1 1 1 1 1 1/ r it 1 11 I n r N 1 rt f rt OF TOTAL NUMBER OF FASTENERS AT MULLIONS / -� � t 4010 '� � 7 1 8 0 $ 0 1 a I� 10 ® ma M-3 MULLION + t n i _ ii t_ u / it t u 1 w TOTAL NUMBER OF FASTENERS PER EXTERIOR EXISTING \\ !! MULLION + + 5 MULLION + + 5 - a 6 5 8 a 8 " 0 1 a - 0 10 - 0 CONI�CTION AT NUW�I CONNECTION AT HEAD/SILL EQUALLY W/ HEAD/SILL CONNECTION PER SCHEDULE, -J Tf.UCTURE � �� p Hoo ,C�%� N 1 w t 11 , „ , n 1 n INSTALLED AT EACH SIDE OF MULLION (BY OTHERS) � ���•'•�\CENS�'.�•� 5 - 6 5 - 10 8 - 0 8 - {? � - 8 9 - G7 '- V 11 51 _ 4 " `« " 7 '" 4 " $ `- 11 " 8 '- 11 " - �: - .' F •O�: } " , . tl 1 It 1 - 11 /� MAXIMUM A.S.D. DESIGI RESSURE (RATING SCHEDULE FOR MULLIONS 0 HEAD/SILL CONNECTIONS # CONNEC 01 ArT AMM 6 - 8 4 - 110 $ - 7 6 7 8 '_ 1l t1 8 r_ _. _ 3 , 0 If 8 t 0 w 8 r 0 i1 8 f 0 N 10 1 (; w 1{ Q ri MAXIhIIkIM 14.S,ty.L L SiGfV PI OURE RATIN psf _ _ _ -- - - - _ - N #, 6 - N t If ! � ti .. '. _.. ._. .. .._ .. _ 60.. -- 0 531 3 I- 8 'I 8 ' - Q " 8 '- 0 " 8 '- 0 10 - 0 10 - �nlcll�+� EFFECia 7s�U�f*Q OaN��rr� �� STEEL t n 1 N 1_ N I w I ry I Ir MULLION i 1120"Min,THK, 11$"Min.THK, I t 45.0 1 _ 0 N r - 1 I: 8 f. 0 n 8 r" a N 1 a t ^ O N 1�} i- 0 if SPAN SPAgNR SUB&TRATE 9U813TRATE SUBSTRATE STATE OF �� 4 - 6 6 « 4 8 - 0 8 - 0 110 - a 10 - a 1 r1 r N i n , It - r 1r 1 It FASTENER TYPE FASTENER TYPE FASTENER TYPE FASTENER'I°YPE � � F�ORIDp;.•.•'•,���� 5 - Q 5 " 8 7 - 10 7 - 14 0 - 6 9 ,{� . 'I 5 t _`.� N 7 1- 1 N 7 1 1 .a 8-'- 7 N 8 r_ � w 10(1/4"fD) F�(1 f4"D3} BI(51wo) C(11'4"0j � s�i' W.�.... •• +• ,,. .' _ i tl 1 - ti 11. -(- it r N - r if nen 8- nn4.. n�6" n*a,:f, n6 n-6 O�MA�. `\_\ 3 --a S - -0 8 - 0 S - 0 10 - 0 1 Q _ -C} "L" FE-in "b"(Ft-in) 1 *4 "s n k 8 n s 4 n 6 _ 1 li i w =-t 11 1 Il I I1 I II- 3 '• a" o:a_ 50,0 sa.� 30.4 5510- 60.0 -- -50.0 5010 6010 sola eo:a - - - 3 - �i 7 - 4 8 " a �3 - fl 1 t� - t} --10 - -��- 10:0 _6010 -60,0 33.a 50.7" 6010 Go.o- 60,0 -59.6 6010 6010 r __ n 1 11 1 - N i N i w ii _ 3'" 5 " I 111 1 t 50-.0 4 - 0 6 - 5 8 - 0 8 0 'ta- - 0 10-'- Q 4 ', d." 5.0 -5510 ss.a 29.5 44.3 55.0 56.0 85.0 y _ F 1 52,1 55 tL5 o FASTENERS TYPES: (SPACED AT 4"o:o.) 1 - 6 1, f n 1 le 1-10 1I t u r /r 8' a " 4 • 6" d.0 55.0 55,0 26.3 30.4 62.5 55.0 55,0 46.3 55.0 5$.0 _5 « 8 7 " 10 7 --"t 0 9 - 6 9- - 6 It r If r 11 t N- : 11 1 n OR LESS 5 `- 4 " 5.0 50.0 50,0 23.5 35.5 47 3 80.6 50,0 41.6 Solo 5 `- 0 5 - 1 7 - 0 " -0 8 - .". $ - - 5 ', 6- d:o 50,0 50.0 21.5 32,2- 43,0 50.0 50.0 37.0 50.0 --50;0 A-114713 -EL,CO' Aa"T1MNI IC;SYSTEM,LLQ, UL Tf AGON ANCHOR - -� � 4 FI I II r 11 1 rF 1 1i - 1 11 51 S9 ,-----� Wpsf 3 - Q 7 - 9 8 - 0 8 - a 10 - -0 10 - 0 - $1. " -� q 7.5 50,0 5b.0 19,, 2E)3 39.4 50,6 Solo 34.7 60.0 $0.0 W11 314"Min..EMBEDMENT INTO POURED CONCRETE 1 N r If 1 n r rr t 1 N 1 is - 5 ' $ " 3.6 $0.0 50,0 17 7 28,8 35.5 60-.0 50.0 312 46,0 50,0 (MIH 1"C x 2.730 ksi)OR WJ 1 174"Min.EM 150MENT-INTO X55.0 3 - 0 6 - $ 8 - 0 $ - 0 "a - 0 110 - a 1 N 1 11 r 11 t 11 r 1i r 11 3 '- Q " 5,035,0 55.0 37,1 55,0 05.0 56.0 55.0 55.0 55,d 55,0 HOLLOW�BLOCK(Min,f m�1,9974 ks!) &V MIN, EDGE - a 5 - 10 $ - 0 $ - 0 9 - 13 -0 - $ 3'• 6 " 5.0 5%o 55,0 31.0 47,7" 58,0 55.0 55.0 5'5.0 58.0 55,0 DISTANCE,BEYOND ANY FINISH MATERIAL.. DRAW 7 r 1 1I I 1 II Q 1_ •y li f3 1_ r) N BY: '• 8 ( 8 4 '• 0" 2.9 53.0 55,0 27.8 41.7 55.0 65:0 55.0 49.0 55:0 $5.0 ' rt + N 1 n 1 If r u r 11 - 0 7 - 1 8 - 0 $ a 1 a - 0 10 - 0 8 '• 6 " 4 '. s" 1 $510 55.0 247 37,1 49,4 $6.0 55.0 43.6 55,o 5$.Q B-114!+4 SLCO FASTENING SYSTEM,LLC, ULTRACpN ANCHOR 1, 6 N i ft 1 N 1 tf 1 n 1 n 5 ', 0 " A 5010 solo 22.2 $3.4 44.51 60.0 50,0 39.2 60.0 50,0 KEVIN 0010 36 - 1 8 - o S - a 1 10 - 0 10 - 0 t a f N 1 n r is 1 w r N $', 011 .S $0.0 50,0 20.2 30,9 40,5 50.0 Solo 3$,6 5d,0 5o,:0 W19 112 Min.PENETRATION INTO 2 X WOOD SUCK(G= .55) 4 _ a 5 4 7 4 7 - 4 $ - 11 8 - 11 s ' 0 - .3 50.0 50.0 10.5 27,8 37.1 6d.b 50,0 32.7' solo Salo &2"MIN.EDGE DISTANCE,BEYOND ANY FINISH MATERIAL. 6'• G " 8 47,8 50,0 96,7 25,0 33.4 50.0 50,0 28.4 44,1 50.0 ry 3'• a " 0 65,0 55.0 3610 52.5 SSA 55.0 55.0 55.0 55.0 5$10 E'-;116"O ELCQ FASTENING SYSTEM, LLC, ULTRACON ANCHOR U LLi D N CASE V G. NIT N S 3 '• 6 " .0 55.0 53.0 30.0 45.0 5510 55,0 5510 $219 55;0 5'3,0 W11 112"Min.PENETRA11ON INTO 2 x WOOD SUCK(G=0.55) 4 - 0" :0 55,0 3510 26,3 38.4 $2.5 65.0 65.0 46,3 55.0 $510 &161811 MIN,EDGE DISTANCE,BEYOND ANY FINISH MATERIAL 9 - 0.1 4'. 15" .4 solo 5510 23.3 36:0 467 Oslo 55,0 41.1 5510 55.0 CASE 1 UNREINFORCED STANDARD 5 1- -0 " .0 50.0 $0.0 21,0 $1.5 42,0 50,0 Solo, 37.0 5d;o 50,0 C.114"0.20 SLOTTED INDENTED HEX WASHVI'i HEAL?THREAD" 5'- s, 3 .4 $0,0 50.0 19.1 28,7 . 38,2 5.0.0 50;0 33.7 50.0 5o.o „ MULLION Intl -- (SEE DET. 5/9) s'- o " 3 .3 50,0 50.0 17,5 26,3 $510 5d.a 50.0 30,9 46.3 $0,0 CUTTING SCREW TYPE`r",ZINC COATED,W1 MIN,Fy-77 kei, Fu=1.00 0'. 8". .0 45.0 50.0 15.0ksi TO 118"MIN,THK. ASTM A-36 STEE 23,6 31,5 50.0 $0.0 27,$ 41,6 sola L& 1"MIN:EDGE DISTANCE, CASE 2 : REINFORCED STANDARD '• 0" .0 55,0 55.0 33.2 4s.$ _ i 5510 5510 solo 5510 --Fs-0 55,0 3' a" 1 5510 55.a 28.4 42.7 55.0 5510 $510 60.1 65.0 55.0 MULLION M---2 (SEE DET, 6/9) 4 '• 0" 4 .4 55.0 55.0 24,9 37,3 49.8 05.0 55,0 43.8 55.0 55:0 I : 9 '" 6 "'. 4 '• 6" 4 A 5510 55.0 22.1 33,2 44.2 $5.0 55.0 38.0 55,o 50.0 STOREFRt NT ELEVATION W/ MULLION MULLION- CASE UNREINFORCED STANDARD sf- b" 3 .9 50,10 5010 1919 2919 39.8 5000 sola 35.1 50.0 $0.0 MULLION SEE DET. 7 9' 51• a " 3 .4 $010 50:0 1811 27.1 $6.2 50,0 50.0 31.0 47.8 50.0 MAXIMUM MULLION SPAN SID=E VIEW ��'� ( / 1 6 '• a " �, A 47.4 50.0 1616 24:9 33,2 50.0 50:0 29,2 43.8 $010 T CASE 4 REINFORCED STANDARD 6'- a" 2 .4 42,0 50.0 10 22.4 29.9 00,0 50.0 26.3 395 50,0 N 3 '• o" 9 .0 60,0 60.0 31.5 473 60.0 60.0 60.0 55.5 60,0 Solo O EFFECTIVE SPACING: "b" S1 + S2 ; S1, S2 = MULLION SPACING (o.c.) MULL-ION M--4 (SEE DET, 7A/9) 3'- 0 " � .4 60.0 6L.o 27.0 40.5 54.0 60.0 solo 47.6 60.0 0010 4 '. a" 0 60.0 60.0 23.6 3515 47.3 810.0 solo 41.6 SOD 66.0 uj H M CASE 5 REINFORCED STANDARD 110 '- a ° 4-'- s " '.0 55.0 55,0 21.0 31.5 4210 sold 58.0 3710 55,0 85.0 5'. 0" 31 .0 50.0 5010 18,0 2$,4 37,8 5010 50.0 33.3 SO.b $0.0 LLl (� N * MAXIMUM A.S.D. DESIGN PRESSURE RATING FOR MULLION WILL AUTOMATICALLY QUALIFY A.S.D. MULLION (�--� (SEE DET. 7B/9) 5'- 6 " .7 401 sola 17.2 25,$ 34.4 $Ola 5b.o 30.3 45.4 50.0 M DESIGN PRESSURE RATINGS FOR JAMBS WITH ANCHORAGE FOR ANY GIVEN MULLION SPACING. 6'- 0" 11 .0 45,0 50,0 15.8 23.6 31.5 50.0 50.0 27.8 41.6 50,0 151' a " g'.0 40.5 50.0 14.2 21.3 28.4 48.5 50.0 25.0 37.5 50,0 J J IY _j r� J ' _ _ = m ,Ilkr� Qm V ...I v 1= F-- P z azo O _ Q � Q N O r . I MAXIMUM A.S.D. DESIGN PRESSURE RATING FOR HORIZONTAL HEAD, HORIZONTAL-MAXIMUM HORIZONTAL.SPAN"Ltf])SCHEDULE �' , SILL CONNECTION DETAILS FOR A GIVEN A.8,D,DESIGN PRESSURE RATING s AND (SIDE VIE "- " " SCALE::318 1. A GIVEN HORIZONTAL EFFECTIVE DAY LIGHT OPENING "D.L.O:" in -: MIN. E.B. -MfN, E,D,- .n 1D.L.t3.t MAXIMUMA.S,D. MAXIMUM FASTENEft5 EXISTING STEEL EFFECTIVE FASTENERS EXISTING POURED DESIGN a: CONCRETE STRUCTURE STRUCTURE DAY LIGHT HORIZONTAL • :I � 2x WOOD 1/8" MIN. THICK PRESSUREMIN. E.D. i MIN,�E.D,: BUCK FASTENERS ASTM A-36 �° ( OTHERS) RATING OPENING SPAN ° � 4 ..�• i . 20,,¢4; EO BY O (Pat "DLO"(PWn) 1010 (Ft) • 1/4" MAX. A,1, 9/4" MAX, SHIMSHIM SPACE 11 SPACE I I N SIM SPACED.L.Q.2 Oil " (2) REQ'D {ryR) (2) REQ D (Typ.)2 6I 6 6 2 I Oil G 1" E N I(2)-RE0'D (Typ.) I SECTION AT HORIZONTAL ala 3 1 0 if 6 +" ri OR LESS V EXTMIOR TOR 4 1- 0 w 5 f" 6 w JAMB OR 4 I_ 6 rr 6 1 f n MULLION JAMB OR JAMS OR MULLION MULLION 5 1" 0 is t 8 tr ao (BEYOND) L_ ► u� (BEYOND) (BEYOND) �.-_�.�_� � Hip J x Tvasos ,C v J V E O 25 I. 6 if HORIZONTAL -' HORIZONTAL 3 1 w0 n 5 , 6 1, = 145.0 3 ' 6 "- 5 ' 6 _ T7 NOTES FOR HEAD AND SILL FASTENERS QUANTITY, - C? HORIZONTAL TYPES AND SPECS SEE: SHEET 6. � I a _°.j I 5 '„ 0 II 5_1_ 6 " EXTERIOR ; I _ - fi I_ ('r• a C I 0 USE OF HORIZONTAL (SEE SECTION 2) L iJ Ct VV„ (2) REQ'D (Typ.) LIMITED BY SCHEDULE ON SHEET 7. HAYNES CHIDSEY HORIZONTAL HORIZONTAL = 2 r__.6+- 1f 5 1« 0 3 '- 0 " 5 '- 0 ifJAMB OR FOR GLAZING -DETAILS AND GLASS SCHEDULE OWNER N y, V /-MULLION SEE SHEET 3. BUS.: 704.900.7730 L c; .d. sola 3 '" �'+� it 5 '"' 0 Ir - (BEYOND) CEL.: 303.881 .7314 c N a 1_ 0 if 5 r„ O N FOR MAXIMUM D1L.O. SEE SCHEDULE ON ca � SHEET 3, 4 11 5 1- a iI _ 5r« 0fl 5 +_ 0 ,r 2 i_ 0 n 4 r_ 6 1r JAMB OR JAMB OR 2 r 6 w 4 r 6 rr MULLION /-MULLION JAMB OR (BEYOND) MULLION STOREFRONT ELEVATION W HORIZONTAL g /� q3 ' o w 4 r 6 1r (BEYOND) (BEYOND) -55.0 til '- 6 11 4 t_ 6 II I 4 '" 0 11 4 1 6 Ir EXTERIOR EXTERIOR -4 1" 6 11 4 1 6 rl PROJECT: "L" = MAXIMUM HORIZONTAL SPAN - -- - - 5 t_ D rl 4 r_ 6 SL-FL-253 (2) REQ'D (Typ.) ` ATLANTIC VILLAGE 2 1 0 11 4 r_ 0 •It (2) REQ'D (Typ.) 12)REO'A Iryg•? r'D.L.O." = EFFECTIVE DAY LIGHT OPENING = D.L.Q.1 + D.L.O.2 2 ,- 6 „ 4 ,+ 0 „ .. . RELEASE DATE '.� 1- 0 " 4 1- a u {1 1/2"x1/4" WEEP SEAL LENGTH 4" WEEP SEAL LENGTH r_ n I_ N NOTCH REQUIRED ON <,. MIN E D .'; MIN. E;D. OF SUB SILL NOTCH REQUIRED RED QN MIN. E.D. MIN, E.D. OF SUB SILL (1 1/2"x1/4" NEEP SEAL LENGTH 50.0 S 6 4 (} SEALANT AT CENTERLINE .', ` 'a.' SEALANT AT CENTERLINE NOTCH REQUIRED ON OF SUB SILL EXISTING STEEL O4/O2/14 f Ir 1 ti OF MULLIONS & JAMBS) - a 2x WOODSEALANT AT CENTERLINE I STRUCTURE OF MULLIONS & JAMBS) BUCK OF MULLIONS & JAMBS i 1/B" MIN. THICK 4 - a 4 - a s EXISTING POURED ) 0 5 i ASTM A-36 REVISIONS: �, '_ n �, t " rl CONCRETE STRUCTURE (BY OTHERS) 5 i_ 0 11 4 i_ a n FASTENERS FASTENERS LFASTENERS I BLDG. DEPT. REVIEW-5/23/2014 MIN. E.D,-MIN, E.D. �. .1 L - 13I I Y DRAWING NAME PRODUCT APPROVAL'S SHEET NO. I CS1 .2 jk ° 1 i I I I ' I I J AWE -PRESSU MAXIMUM A.S.D, DESIGN aRNER DETAIL ATJAMB T SECTIONS AT JAMBS (PLAN -- RE RATING & CORRESPONDING s� „q tD POUt�9 C4NCRETt7 Q;�Q IOW fiFf� BLc�ft �I��R� SCALE:3/6'a V3�, MAX,.. � 1 MAXIMUM FASTENERS SPACING SCHEDULE-FOR JAMB CONNECTION V� TO WOOD STRUCTURE TO ( VIE O STEEL-STRUCTURE STRUCTURE � SHIM SPACE HIM MAX. 3/8' MAX, EXISTING, JAMB FASTENERS' SPACING"S C " SHIM SPADE 3/8" MAX, SHIM SPACE SHIM SPACE STRUCT E` MAAMUM 1� (in Q.O,� EXISTING POURED a . HEAD OR SILL ��. (BY Gr RS) A 1�• POUREDGONCRETF WOOD STEEL CONCRETE OR HEAD OR StLL�EXISTING STEEL HEAD OR SILL f� MULLION OR HOLLOW HOLLOW . .,. (BEYOND) I Q /" DESIGN SPACING CONCRETE BLOCK 14 " CONCRETE BLOCK* �. (BEYOND) (BEYOND) N TES: 1 1/ MIn.THK, 1i8 M'rn.THK. EXISTING STRUCTURE PRESSURE SUBSTRATES �������� SUBSTRATE W STRUCTURE I , ._ I' 2x WOOD BUCK Q i/8 MIN. T}ICK FASTS f MATING STRUCTU " ASTM A-36 FOR JAMB FASTENERS SPACING CER hFJEOr �Y: z (BY OTHERS S _ FASTENERS TYPE FASTENERS TYPE FASTENERS TYPE FASTENERS TYPE T\ / z TYPES AND PEGS SEE SHEET 1(?. ) 114 114 s"(511610) 114' �0 ���� :r AEEIN (pso "51"'(Ft-in „ „ „ D. 1-JFOR GLAZIN G DETAILS AND 3 '» 0 " 12 12 12 12 ��.`'� ' \GENSF;STENERS FASTENERS FP, Ria �-c , Y� F ' .oo GLASS SCHEDULE �t� SHEET 3. 12 12 12 12 I"ASTEN�RS TYPES: (SEE SPACING SCHEDULE) .�.: 12 12 12 12 _ . FOR 4AXIM M D.L.Q, SEE f 4 ' 6 " 12 12 12 12 No.60531 49n *` I SCHEDULE N SHEET 3. --• 35 Q 5 `_ 0 " 12 12 12 12 A-114" ELC4D FASTENING SYSTEM,LLC.ULTRAG4N ANCH:OP •' _ c' `: /1 L 12 12 12 12 14" in.BMBEOMENT INTO POURED CONCRETE a 1/41 MIN. DEPTH JOINT - d 1f4° MIN. DEPTH JOINT _ ' OR. ._ „ (�- ? w/ /a'MIN, DEP 1 i W/ 1/a' MIN. DEPTH 1/4"MIN, DEPTH JOINT EXTERIOR � 0 12 12 12 12 (Min:fc 2.730 ksi) CAR Wl 1 114' Mln.EMBEDMENT INTO. AT MIQW{OTH [If JOENT AT MID!DTH t�`J41NT W/ 1/8"MIN, DEPTH `' B " 12 12 12 12 I HCILLOW BLOCK(Min:fin 1.924kSljA 1"MIN,EDGE �-�® STATE OF ��� ! W/ SEALANT w SEALANT AT Mu�wmTH OE JOINT + 3 '� 0 " 12 12 12 12 b1$tANOE,BEYOND f+INISHMATERIAL. FIOR►DP.•` I ,, " OR EXTERIOR OR EXTERIOR w/sEAEANr OR EXTERIOR _ 3 '- 6 " 12 12 12 12 X61 ........ �G 3/18" MIN, a/au MAx — SEE DETAILS 4 '- 0 ' 12 12 12 12 R-114 ELCa FASTENING SYSTEM 1,(,C:ULTIACON ANCHOR �i O1VAl. �� ON SHEET 9 '- " /111111111\\\` 3/16' MIN, & 3J8 Max. WIDE Jouvr w/ ssaLANr i X 40.0 4 1. 6 ti 12 12 12 12 W/1 112"Min,PENETRATION INTO 2 x WOOD BUCK(G=0,55) WIDE JOINT W/ SEALANT �& 3/18" MIN, do 3/8' MAX,..- 4 �/ 5 0 12 12 12 12 &2"MIN,EDGE DISTANCE,BEYOND ANY FINISH MATERIAL. WIDE JOINT W/ SEALANT 1 5 '= 6 " 12 12 12 12 S E l I I V S AT M U L.L f O 1 V 6 6 S {� \\ 6 0 ; 12 11 1/2 12 12 B'.5m wo EI.CO FASTENING SYSTEM, LLC:ULTRACON ANCHOR { �• 12 10112 12 12 �i •\> 3 '- 0 -1 12 12 12 12 MAX. D.L.Q. SCALE:3/S 1° 3 6 W11 112"Min.PENETRATION INTO 2 x WOOD BUCK(G=0,55) T, 1,2, /$} it . 12 12 12 12 &1 515"MIN._EDGE DISTANCE,BEYOND ANY FINISH MATERIAL - I �� / (rrP,) � - -- , HEAD OR SILL (BEYOND) i HEAD QR--SiLL 4 I ~ \ \�1 I 45.0 4 6 " 12 12 12 1.2 {.,114'-'0=20-$LCLTTED I,NDENTEDLHEX WASHER HEAD THREAT I I, HEAD SILL (BEYOND) - l 5 ' __0 " 1-2 12 12 12 CUTTING SCkEW TYPE 1—ZINC COATED,W/MIN:Fy=77 KsI,Fu=10D 5 6 " 12 11 12 12 Iasi TO 1/8"MIN,THK. ASTM A-W STEEL& 1"MIN:EDGE DISTANCE: .0 „ 12 10112 12 12- B 12 -9 12 -1-2 `- o " 12 12 12 DRAWN BY: NOTE: INDICATED- MAXIMUM AND MINffUM VALUES FOR SPECIFIED 3 '- 6 " 12 12- 12 12 SEALANT VERTICAL JOINT WIDTH AT JAMBS CONNECTED TO \ i 50.0 4 '» 0 " 12 12. 12 12 WALL HAVE BEEN DETERMINED ONLY TAKING INTO ; 4 - 6 " 12 12 12 12 KEVIN CONSIDERATION THE ACTUAL MOVEMENT OF GLASS WALL AT .�^ f 5 '- 0 it12 11 12 12 ._ JAMBS DUE TO THERMAL, WIND AND ITS OWN �\ 31- oil 12 12 12 12 CONSTRUCTION TOLERANCE, AND NOT PERFORMANCE S /� 55 Q 3 '- 6 it 12 12 12 12 . FACTORS FROM THE SURROUNDING STRUCTURE, 4 ' 0 " 12 12 12 12 \� 41y 6 „ 12 11 12 12 {2} 12 12 12 12 \ \� 80.0 3 'w 6 " 12 12 12 12 -- - E3tTER1�3R s 4 ` 0 " 12 111/2 12 1.2 illi _ HEAD SILL HEAP SILL (�' HEAD C3Ri SILL HEAD OR SILL (SEE DET, 1 2,38) IL!1 (BEYOND (BEYON i (8EYON (BEYOND) I1 i N O) uj1 Lu C41 f f \ (� N J w LL EXTERIOR EXTERIOR (2) � .\� VIEW "xn �_ d z M--3 �A M--4 M -5 (ISOMETRIC) o > J v5Lu � 0im � amv >. z az < d � Q N I' I i I I I N TUD195 I I HAYNES CHIDSEY OWNER BUS.: 704.900.7730 CEL.: 303.881 .7314 PROJECT: SL-FL-253 ATLANTIC VILLAGE I RELEASE DATE 04/02/14 REVISIONS: 1 BLDG. DEPT. REVIEW-5/23/2014 i, it DRAWING NAME I PRODUCT APPROVAL'S SHEET NO. CS 1 .3 i I I I I i RELOCATE EXIST. GENERAL FLOOR PLAN NOTES ELECTRICAL PANELS DEMO WALL TO DEMO DOOR DEMO DOOR TO NEW LOCATI N ACCOMMODATE 1. ALL WORK SHALL CONFORM TO APPLICABLE FEDERAL, AND IN-FILL TO AND IN-FILL TO R-,� NEW DOOR STATE AND LOCAL CODES. ii MATCH ADJACENT MATCH ADJACENT II CONDITIONS. CONDITIONS. ' ` 2. THE GENERAL CONTRACTOR HA u OVERHEAD SHALL OBTAIN ALL ° NECESSARY PERMITS AND SHALL PAY ALL REQ'D V n COILING DOOR Z -- FEES FOR THIS WORK. _ _ N '� 3. THE GENERAL CONTRACTOR SHALL FIELD VERIFY 6 - I I 7- ► 9'-1 1 1/2 --- 9,1111/ ° 4-1 /2 2-9 9'-9 1/2" FD - °O EXISTING CONDITIONS AND REPORT TO SYMPATECO, P C -- — 0 I , I _ __ r--- I (V �' MECH. J INC., IN WRITING, ANY DISCREPANCIES IMMEDIATELY M ---- I I L-----J � UPON DISCOVERY. I , Ico M S i i `���pLWE 4. UNLESS OTHERWISE NOTED DIMENSIONS FOR ALL D - -- - i i FD I -- o '� i i NEW'�i i i BOARD. ARE MEASURED FROM FACE OF GYPSUM T- ti v v A DIMENSIONS REFERRING TO EXISTING WORK -WOMENS —O L — --J I I — FT I ' BREAK RM. STUDIO 109 L____J L__ ARE MEASURED FROM FACE OF EXISTING FINISH. gj N 1 EQUIP. 00 5. EXISTING WALLS TO REMAIN, SHALL BE REPAIRED AND ' `V REFINISHED AS REQUIRED TO PROVIDE A SMOOTH AND a� r - ' ►i UNIFORM SURFACE FOR THE APPLICATION OF NEWLY CERTIFIED BY: ,� , N „i ; ►'►► INDICATED FINISHES. _ 6 3 = 5-8 /2-= -6 1/2" 9'-7 1/ _ 1ICE STUDIO 108 �'1►IIII1r11� bo _ c��l w ♦ 6. THE GENERAL CONTRACTOR SHALL, AT ALL TIMES, \������N D. it 0 KEEP THE PREMISES FREE FROM ACCUMULATION OF �'�� �►cervsF��'A �'� N o ° '. WASTE MATERIALS OR RUBBISH CAUSED BY THE �O '-1 1 '-4" — ° 1 M - - - WORK. AT THE COMPLETION OF THE WORK = No. - 6053 _ CONTRACTOR SHALL REMOVE ALL WASTE MATERIALS '� _ 4 _ AND RUBBISH FROM AND ABOUT THE PROJECT AS �,� '•. o STATE I r I N 01: •�C/ WELL AS ALL TOOLS, CONSTRUCTION EQUIPMENT ANDLO c�ORIDP••.•''���; co MACHINERY. o 7. ALL SURPLUS EQUIPMENT AND MATERIALS ARE THE -- � � STUDIO 11 STUD101 0 I I STUDIO 107 —' CID * PROPERTY OF THE OWNER. THE GENERAL NI ZD CONTRACTOR SHALL COORDINATE WITH THE OWNER N THE DISPOSAL OF ANY AND ALL SURPLUSES. STUDIO 112o r— M ° 8. ALL WORK SHALL BE PERFORMED IN A MANNER DRAWN BY: All A73 ° 9'-9' = 3-11" 9-11 1/2" ,��' iYi N WHICH LE J AST DISRUPTS THE BUSINESS PROCEDURES ► 0 3'-9" �`' 1'-7" 3'-11" q c) OF ANY NEIGHBORING BUSINESSES. KEVIN 11 N -- N ° --- ---- ��� ; 2'-0" 20'-5" 2'-0" 1 9. TFE CONTRACTOR SHALL INDIVIDUALLY WARRANT FOR ' I ONE YEAR ALL MATERIALS AND WORKMANSHIP 1 ► CLOSET i i EXCEPT AS OTHERWISE AGREED. �( M �� �� �� �� 11 STUDIO1 66 — 11-6111, 3-1 15-4 3-0 1 -6 ' ' ► 10. G.C. TO PROVIDE PROPER VENT FOR CLOTHES DRYER w LO (WHERE APPLICABLE). 4xi 31 M i � l8E ' 11 . ALL 'HOLD' DIMENSIONS ARE CRITICAL AND TO co FINISHED FACE. co 1 ' STUDIO 113 1111 * ► W 12. CONSULT THE SOLA DEVELOPMENT MANUAL FOR m ► ► _ STUDIO 121 STUDIO 120 — 1 C°_ ADDITIONAL DETAILS, SPECS, AND INFORMATION. r ' 1 N d7 N UJI ~ M 1 -1 i� oo N d 13. GC TO REVIEW AND VERIFY ALL DIMENSIONS PRIOR TO U _ STUDIO 105 —' W CO N lst * COMMENCEMENT OF CONSTRUCTION. ANY ® J N INCONSISTENCIES WITHIN THE CONSTRUCTION Q J N DOCUMENTS ARE TO BE REPORTED TO SYMPATECO, J > = 11'-6" 5'-3" - 5'-8" 12'-1 1/2" :� INC. IMMEDIATELY. O > Q - b � w 0 � Zpm 14. GC TO PROVIDE DRAIN CLEAN � OUT ACCESS PANELS 0 z m v i ► a M PER PLUMBING RUN OR AS REQUIRED PER LOCAL p J U P + 1 , rn E- � z STUDIO 114 11 i CODE. Z J 1 STUDIO,j122 STUDIO 119 1 Q 1 i 11 15. GC TO PROVIDE METAL THRESHOLD TO HOLD ANY Q Q °� i 1 w_ f� - WATER OVERFLOWS WITHIN THE LAUNDRY OR 1 ' ' 1 � ' ► I STUDIO 104 —' j M 1 -4 i ► , 4 MECHANICAL ROOM. o 1 � ' 16. ALL DETAILS ARE TYPICAL U.N.O. TYPICAL DETAILS m _4 ► AND NOTES MAY NOT NECESSARILY BE REFERENCED TAILS SHOWN FOR SPECIFIC LOCATIONS ►i ►' ► SHOW THE "DESIGN INTENT"► -4 �► c� 1 �' ENT FOR SIMILAR MATERIALS AND OCCURRENCES. SPECIFIC DETAILING NOT SHOWN � M ► BUT USING SIMILAR MATERIALS T 1 STUDIO 115 1 � ' = 1 ' 1 , � STUDIO 123 STUDIO 118 11► � � O THOSE SHOWN ARE ► _ TO► , ► 1 1 co CARRIED OUT PER SYMPATECO INC.S DESIGN ' ' ►► * o� i 1 `.: INTENT". 0'-2" '� 11'-1" 13 ;; N 17. WALL THICKNESS MAY VARY FROM PLAN AS SHOWN 1 j DEPENDING ON LOCAL REQUIREMENTS AND EXISTING M 6-2 5— STUDIO 103 CONDITIONS. c— r °CD I CV C) i N 4'-9" 1'-6" 21'-7" 1�_6�� 4'-9" N I _ I O I 0i � L i 11-511 `n 11-511 ------ -- _ _ ---- — ----- ------- EO 41-511 4 I N Tomos LO I s ♦ i I STUDIO 116 * I N I NOTES.- LID OTES: I STUDIO 117 04 ° STUDIO 101 STUDI0102 I I 1 . N FPA 101 - 7. 10- 1 . 3 EXIT DOOR TACTILE SIGNAGE. TACTILE W6 0 I i SIGNAGE SHALL BE PROVIDED TO MEET THE FOLLOWING 00 CRITERIA, UNLESS OTHERWISE PROVIDED IN 7. 10. 1 . 4: HAYNES CHIDSEY (1 ) TACTILE SIGNAGE SHALL BE LOCATED AT EACH EXIT OWNER 12-1 8'-0 1/2 11'-7 1/2" 17'-7' DOOR REQUIRING AN EXIT SIGN . BUS.: 704.900.7730 2 TACTILE SIGNAGE SHALL READ AS FOLLOWS: EXIT. CEL.: 303.881 .7314 DEMO DOOR. `%33'-2" I 3 TACTILE SIGNAGE SHALL COMPLY WITH ICC/ANSI IN-FILL W/ �� a !, A117. 1 . AMERICAN NATIONAL STANDARD FOR STOREFRONT MODIFY STOREFRONT ENTRY TO'---y DEMO DOOR. ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES. TO MATCH ACCOMMODATEANEW DOUBLE IN-FILL W/ 2. PER FLORIDA ADMINISTRATION CODE 69A- 60. 0081 NOTICE ADJACENT DOOR ENTRY. STOREFRONT CONDITIONS TO MATCH REQUIRED FOR STRUCTURE WITH LIGHT- FRAME TRUSS- ADJACENT TYPE CONSTRUCTION , PROVIDE LIGHT WEIGHT TRUSS PROJECT: CONDITION IDENTIFICATION SIGNAGE. SL-FL-253 j ATLANTIC VILLAGE RELEASE DATE 04/02/14 REVISIONS: 1 BLDG. DEPT. REVIEW-5/23/2014 DRAWING NAME FLOOR PLAN & NOTES FLOOR PLAN & NOTES N SHEET NO. A1 . 1 e I i REMARKS: 10 AT RESTROOMS, ALL WATER CLOSETS, URINALS AND TOILET ACCESSORIES (i.e., GRAB BARS, PAPER TOWEL DISPENSERS, TOILET TISSUE DISPENSERS, iSANITARY NAPKIN DISPENSERS) ARE G.C. - PROVIDED AND INSTALLED. G.C. TO PROVIDE POWER FLUSH TOILETS AND C13 RESTROOM SINK (S). GENERAL CONTRACTOR OR SI TO PROVIDE SOLID SURFACE COUNTERTOP, UNDERMOUNT LAVATORIES AND FAUCETS AS INDICATED. INSTALLATION PROVIDED BY OWNER'S INSTALLATION COMPANY. G.C. TO COORDINATE. U 02 OTHER COMPANY TO INSTALL SECURITY SYSTEM A�1D KEYLESS ENTRY SYSTEM. Z II ® GC TO VERIFY ALL TVs & LOCATIONS WITH OWNER. PROVIDE ALL NECESSARY SUPPORT BLOCKING. ® SPEAKERS TO BE TIED TO RADIO IN EQUIPMENT CLOSET OR LAUNDRY ROOM INSTALLED P BY G.C. (CHECK ' WITH OWNER REGARDING SOUND SYSTEM) NEW ELECT. PANELS SOLA DIVISION OF WORK 03 ITEM G.C. OWNER SYMPATECO, OWNER'S ITEM INC. INSTALLERS REMARKS 94 EXIT FURN INST FURN INST FURN INST FURN INST ° o° FURNITURE (STYLING & SHAMPOO CHAIRS) XI x oa 0- I I O ° r,� MECH. 2 I I � �`� FIN FIT ' C17 ® ---- i _____ i FIN FIT LAMINATE FIXTURES X CERTIFIED BY: 1a L ' EQUIP. (SEE FIXTURE LEGEND) X 2 __ �� SHAMPOO, BAR SINKS IN A1.4 MENS L--C1--J 17 /CLOSED UPPER C17 x x ❑ ® O i-----i ® A1.4 FI a� --icy STORAGE ABOVE F— _ A 1 I C3� A G ^ LAMINATE FIXTURES I I r__11 I E7 II /I 1) I1 /I " I1 �111111111/�/ ❑ I — 21,15 STYLING MIRRORS 1 I C1 I _ � I I I I I I I I I 1 1 I I 2 I 11 �� I/ \I . I/ X I I I A1.4 1 2 1 v �. v v ,, J WASHER & DRYER X X BREAK RM. L- J STUDIO09 L---_J L_ oll No, 60531 _ .. REFRIGERATOR MICROWAVE14 x X _ 1. WOMENS ; �� ; ' 2 BAR STOOLS RECEPT. SEATING X, x4,15 _-� 1 1 AlA E FIN ' o.• i _ A1.4 WATER HEATER / STORAGE TANK STA �•�44/ X X TE OF /�'� �''�� 1 ,�1_ ► 27 f • .�< 1 � STUDIO 108 11a II 16,13 OR IN-LINE WATER HEATERS i / Ea M2 MOP & UTILITY SINKS x x! OliIAL SID 11 N��\� RESTROOM FIXTURES X x'' /►1111+11 /5,76 �/ 36 90 Ala E1 T I RESTROOM GRAB BARS, TOWEL 3U 17 21 ° 7 313 3U 3U 7 C..-�TV ® ► M1 & T.P. DISPENSERS X x 1 14 n n p o _ l9 IT/ I 17 ° 1 1 `rI PNFI I go 3u RESTROOM MIRRORS x x M1 FIN FIN FIN FIN FI M1 IT FI — — ( ❑ 117 STEREO & DVD ® 15 M2 � DRAWN BY. E1 FIN FIN �\ E1 36 E1 FI FIN II i gp 36 3U X X 36 5,15 9,4 / ` FI FIT /� 5,10 I 1 27 1 1 FITFIT ` A14 // / ♦ A1.4 I I ® � FIN IT FI TV'S & BRACKETS x x 3 SECURITY SYSTEM/ KEVIN ♦` A1.4 \ E4 m1 \♦ M2 M6 \\E M2 \\E / ' 416 �♦If E1 X 20 5,15 FIT/FIN 19 ` I ► 9L A1.4 ,,/ ` KEYLESS ENTRY SYSTEM 2 FITFIT 54 C_--�TV A1.4 FIT/FIT i i 27 1 `\E4 ' m MAILBOXES X x ❑ 2 A14 ► �' 17 LIGHTING FIXTURES (CEILING) x x 4,15 ❑� 5,8,4 A1.4 5a STUDIO 111 F� FIN FIN STUDIO 110 ' STUDIO 107 5,15 FTFIT LIGHTING FIXTURES (WALL SCONCES) x x A1.4 FINOIN STUDIO 112 FI FIN SLIDING GLASS DOORS X X COAT HOOKS ON SLIDING DOORS x x J DROP CEILING•SYSTEM x x 17 I 1 15,4 Ea 27 FIT/FIT / 1 1 METAL CEILING TILES x x / ♦ 1 - - 9 - FI FIN STUDIO SIGNAGE x x r / ♦ — ----- ® M1 _ \ A1.4 1 1 27 27 54 1 ► STUDIO 106 A1.4 li DISPLAY SHELF X X E1 1s 1 1 F a ENTRANCE LOGO X X W M2 ► I® CLOSET j 1 `♦ II g A1.4 Tyl7 2719 l Ea M2 DIRECTORY X X H I \\ 3U FITFIT FIN FIT ® ❑ 1 I A114 ` IiTFI FLOORING X X M 3U 17 __—_, 2__ IS _ _ _� � 01 ; 90 E1 GARBAGE DEPOSAL x X Q IJL J M1 IT FI ► 1 "'-- — 17-11M1 CEILING SPEAKERSx X T4 v 1 ► ® 90 FI 17 E1 3U 3B 5,16 ► 1 4zz I,=4 V = W FITFIT /� ` A1.a STUDIO 121 A1.4 5 STUDIO 120 90 M18 IT BI 3U A 1- ® m M2 {`' ❑ `` ► 27 \; FIPIT 17 Al.4/ ® � FIN/FIT SOLA FIXTURE AND EQUIPMENT L a m `_' LEGEND _ ♦ / i 1 54 / E4 M2 % `\ 54 / / M2 � � ..I �1a `\ ► ► ♦♦` ,� m1 Ea ` a,1s ,C\♦ E1 1 RIGHT TALL STORAGE-SI 44 3 1/2"STEP STOOL-SI Q Z Q FITlFIT ► 5,16,1 �/ 313 i/ a,1s,1 A1.4 / / `\� 309 4-6" MIXING/COLOR CAB.-LOCKING DRAWER-SI � _I ® H 2 LEFT TALL STORAGE-SI Fes•- Q 4,15 STUDIO 113 Ala E1 TFI E1 �� A1•4 27 I I ` E4 M1 45 STORAGE/DRAWER STACK W/FIN. REAR PANEL-SI 3100 4'-6" PER STORAGE CABINET-SI FIN/FIN A1.4 M2 I I `\ /� 3U CORNER UPPER DISPLAY W/SHELVES-SI 46L LAUNDRY STORAGE CAB. SINK ON LEFT-SI Q (� L.f ❑ 17 M1 3g 18 7PF 1 i 5,15 F,I FIT 3B CORNER SHAMPOO UNIT-SI 46R LAUNDRY STORAGE CAB. SINK ON RIGHT-SI o F 90 FIT FIN 3U 3U FI IT FIN T 90 STUDIO 105 q1•a 3B-R CORNER SERVICES UNIT W/20 X 20 SINK-SI 47U UPPER LAUNDRY STORAGE W/12C-SI C1 COMM. STACK WASH/DRY-OWNER FIN N 4 24"W SLATWALL DISPLAY/SHELVES-SI 48 ADA LAUNDRY COUNTER W/SINK-SI C2 TOR-OWNER FI"r'" 5'15 2 5 48"W SLATWALL DISPLAY/SHELVES-SI 49 STYLING CART-SI C3 LOCHINVAR WATER HEATER -G.C. 4,15 FI FIN �1 A1.4 STUDIO 114 1 STUD10122 A1.4 FPIN 5,15 STUDI0119 17 A1.4 7 42"W SLATWALL DISPLAY/SHELVES-St 50 TOOL CAB. W/FINISHED REAR PANEL W/CUTOUT-SI C4 MOP SINK-G.C. 1j ► 00 F \ FI 1FIT FIT71T �/ ♦ III 15,a FI IN 8 36 Y"W SLATWALL DISPLAY/SHELVES-SI 51 STORAGE/DRAWER STACK W/FIN. REAR PANEL-SI C5 MAILBOXES-G.C. M1 E4 1 ❑ 27 i i Ea M2 / \` 1 I 27 A1.4 9 24-Y2"x 45-Y8"SLATWALL DISPLAY/SHELVES-SI 52 LARGE INTERIOR STUDIO WINDOW-SI C6 WAITING CHAIRS-OWNER M1 E4 / 1 / I ► STUD10104 I 10 5'-0" MIXING/COLOR CAB. -SI 53 NARROW INTERIOR STUDIO WINDOW-SI C7 DIRECTORY-OWNER M2 ' 1 1 1 A1.4 IT I \� a,1s ► ► rl� ♦ FI 54 48"X 48" INTERIOR STUIDO WINDOW-4 PANES-SI C8 FUTURE PEDICURE-STUDIO TENANT 1aI �' ' E1 � M2 A14 z7 M2 I 12U LUNCH COUNTER UPPERS-SI \\ /� I 12C LUNCH COUNTER W/SUPPORTS-SI 57L ADA LAUNDRY STOR. SINK ON LEFT-CLOSED UPPER-SI C9 COMMERCIAL WATER HEATER BACK-UP- FITFIT FIN/FIT 90 ❑ I M1 II 16,5 ` / G.C. 1a ®_ _ B 14L SKINCARE STORAGE SINK ON LEFT-SI 57R ADA LAUNDRY STOR. SINK ON RIGHT-CLOSED UPPER-SI C10 MICROWAVE-OWNER Co���TV 90 FI 17 N 3U 3U FI 3B� FIN FIT 90 1 1 1 A1.4 C����TV 1 1 E1 3U 17 90 C���'TV 9® 1 1 M1 11 F 11 ► ► ❑ s0 3B 3u 3u 90 C— —�N ► 1 14R SKINCARE STORAGE SINK ON RIGHT-SI 58L ADA LAUND. STOR. SINK ON LEFT-MICRO. SHELF-SI C11 BAR STOOLS FOR LUNCH COUNTER-OWNER ► 1 9 1 1 [1g FIT 17 ❑ ► 1 M1 I 1 I ® ► / FI"'r" m1 I"" ► I 90 17 u 14U SKINCARE UPPER STORAGE-SI 58R ADA LAUND. STOR. SINK ON RIGHT-MICRO. SHELF-SI C12 LAUNDRY UTILITY SINK-G.C. F 36 E1 5,1s ► I 9L ►I M2 FI N i 15L 3'-6" MIXING/COLOR CAB SINK ON LEFT-SI 59 DRAWER STACK W/FIN. REAR PANEL-SI C13 RESTROOM/ 1 E1 E1 1 I A1.4 4,16 'r\ 36 5,16 1 ► 90 7a M SINK/FAUCET-GC-(VER. W/OWNER) \\ 1 I A1.4 /// \� FI IT /� AIA 1 1 I 15R 3'-6" MIXING/COLOR CAB SINK ON RIGHT-SI 60 STORAGE/DRAWER STACK W/FIN. REAR PANEL-SI C14 TOILETS-G.C. M2 Ea / 1 I 27 1 E4 M1 `\\ O I 1 _ 1a ♦♦ ►I I► 27 I I `\\ �� mz ♦10/., 2 I I 1s,13 JC � qg 17 NARROW STORAGE/TOOL CAB. (CAB.4 &6)-SI 62L 3'-0" MIXING/COLOR CAB SINK ON LEFT-SI C15 URINAL-G.C. ( ) 62R 3'-0" MIXING/COLOR CAB SINK ON RIGHT-SI C16 RESTROOM MIRROR-OWNER F�T ► I I ,7 ♦` � 1 ► A1.4 I I 18 STORAGE/DRAWER STACK CAB. 5B &7A -SI STUDIO 115 1 5,15 FI FIr FI-77T � ► I1II„ __ I I Aj�.l 19 STORAGE/STORAGE (CAB. 5B &76)-SI 63L SINGLE SINK SOLID SURFACE COUNTER-SI C17 4,15 STUD10123 A1.4 1 '� STUDIO 118 27 1 ELECTRICAL PANEL-G.C. Flmm 2 A14 1 4,15 A1.4 20 STORAGE/STORAGE(CAB. 5B &7B)w/LONGER COUNTER-SI 63R SINGLE SINK SOLID SURFACE COUNTER-SI C18 SECURITY SYSTEM-OWNER zzzzzz FI N 1 C19 CEILING MOUNT TVS-OWNER STUDIO 103 ' 22B SHAMPOO BASE UNIT-SI 64 STOR. (5B&7B)w/LONGER COUNTER, REAR PANEL-SI X TUDION _ 7 22 — � I 22S SHAMPOO BACKSPLASH 67 STORAGE/TOOL CAB. -SI -SI C20 DVD, STEREO-OWNER o _ �i A1.4 ❑ C==3 54 54" COLOR BAR 11 a 22S 22U SHAMPOO UPPERS-SI 68 NARROW STORAGE/DRAWER STACK-SI C21 HI-LO WATER FOUNTAIN -G.C. DOOR W/ SIDE-LIGHT 22U I INTERIOR STUDIO WINDOW TO BE 172,3 NP' 23 23 CORNER BLOCK-SI 71 UPPER STORAGE FOR"X"STYLING-SI C22 IN-SINK-ERATOR GARBAGE DISPOSAL-G.C. OT las I PROVIDED BY SYMPATECO, INC. A1.4or Ala 309 - I 24 T-SHELF-SI 73 SMALL STYLING COUNTER-SI C23 UTILITY SINK-G.C. E2 A1.4 I 27 27 & INSTALLED BY OWNER'S REP'S (TYF. 103 27 _ 0 25 DISPLAY SHELF-SI -- I g® 310U N 74 SMALL STYLING COUNTER-SI C24 FURNACE-G.C. BUSINESS CARD — ----- ----- — —--- 26 ENTRANCE LOGO-SI 3 Z2 75 CORNER SINK UNIT w/RETRO TOP-SI C25 TELE. PANEL-G.C. ------ --------- 310U 27 STUDIO SIGNAGE-SI 776 SHAMPOO BASE UNIT W/MARBLE SINK-SI C26 INSTA-HOT WATER HEATER(BRAND TBD)-G.C. HAYN ES CH I DSEY HOLDER (32 CT). _ _ _ 49 STUDIO 116 COORDINATEF.S ° 16,13 RETAIL 28 COAT HOOKS-SI 77S SHAMPOO BACKSPLASH -SI OWNER . iv i LOC. W/ OWNER 3os 29L LEFT TO RIGHT SLIDING DOOR XO( )-SI 80 SINGLE SINK SOLID SURFACE COUNTER-OWNER E1 CABINET 36 SHAMPOO SINK-TBD BUS.: 704.800.7730 I � STUDIO 117 FI / N 26 FI 1 I" STUDIO 101 A1.4 90 54" COLOR BAR 29R RIGHT TO LEFT SLIDING DOOR OX -SI CEL.: 303.881 .7314 I� 11 I ( ) 81 DOUBLE SINK SOLID SURFACE COUNTER-SI E2 SHAMPOO CHAIR-SI 7a I I E3 1 13 q a I 35 LOGO CLOSED UPPER A1.4 30 DOUBLE SUITE STYLING-SI 82 DISPLAY SHELF-LAMINATED-SI E3 STYLING CHAIR-SI A1.4 12'6 �" °I 4,10,1 I E3 3 20 R -- ( ) 83L 3 0 MIXING/COLOR CAB SINK ON LEFT-OPEN BACK SI E4 ALL PURPOSE STYLING CHAIR-SI A1.4 7 IM8A1.4 7a A1.a E7� 31 LEFT 18" DRAWER STACK 7A WITH COUNTER TOP-SI �_ �� 1a FIT _ STUDIO 102 I I 32 FREE STANDING DISPLAY-SI 83R 3'-0" MIXING/COLOR CAB SINK ON RIGHT-OPEN BACK-SI E5 CABINET 22B SHAMPOO SINK-TBD 49 / ♦♦ FI T A1.4 7 I -- f z5 MP 33 SINGLE SINK SOLID SURFACE COUNTER-SI 84 5'-0" MIXING/COLOR CAB.-OPEN BACK-SI E7 GARFIELD SHAMPOO-SI 49 11 F1 \ ° I z2F � 34L LEFT DOUBLE SINK SOLID SURFACE COUNTER-TBD 85 UPPER CABINET-SPA-SI 74 ❑1 15 I 228 49 II 11 11 E3 II I I E3 I A1.4 49 E1 vt� 1 ❑ 1 a9 34R RIGHT DOUBLE SINK SOLID SURFACE COUNTER-TBD 87R SLIDING POCKET DOOR W/SIDELITE-RIGHT-SI M1 STYLING MIRROR 53�"x 47%" (RIGHT)-TBD FS 9 E5 1 I, ' E2 I 1c_y �_y A154 I 35 BUSINESS CARD DESIGN BOARD-SI 89R SLIDING POCKET DOOR-RIGHT-SI M2 STYLING MIRROR 5877 47%"(LEFT)-TBD PROJECT: PB ENTRY w••� 36 N/A 90 24"W SLATWALL DISPLAY/SHELVES-SI M5 STYLING MIRROR 52 y"X 47 8"-TBD SL-FL-253 23 37 DOUBLE DRAWER STACK-SI 91 3'-0" UPPER CABINET-SI M6 STYLING MIRROR 63"X 47 X"-TBD ATLANTIC VILLAGE SALON SEATING IS MIRROR FRAME HANGING 38L 3'-6" MIXING/COLOR CAB SINK ON LEFT-OPEN BACK-SI 92 5'-0" MIXING/COLOR CAB.-LOCKING DRAWER-SI M9 STYLING MIRROR 51"X 47 3 "-TBD RELEASE DATE T FIXED. (TYP.) FROM CEILING BY OWNE• 38R 3'-6" MIXING/COLOR CAB SINK ON RIGHT-OPEN BACK-SI 93U 5'-0" UPPER STORAGE CABINET-SI M10 STYLING MIRROR 51 %"X 47 X"-TBD FIXTURE PLAN 04/02/14 42 TOOL CABINET W/FINISHED REAR PANEL-SI 98 3'-6" UPPER STORAGE CABINET-SI M15 STYLING MIRROR 50 3/4"X 47 X"-TBD SCALE: 1/4"=r-o" FULL HEIGHT WINDOW REVISIONS: LAMINATED FINISH PANEL 1 BLDG. DEPT. REVIEW-5/23/2014 I DRAWING NAME FIXTURE PLAN & SCHEDULES FIXTURE PLAN & SCHEDULES N SHEET NO. 17 i A1 . 2 • • . .a , i GENERAL DOOR NOTES FINISH SCHEDULE 1. SEE DETAILS 1/A1.4 & 3/A1.4 ON SHEET A1.4 FOR VERIFY ALL SELECTIONS WITH OWNER SCHEDULE & REQUIREMENTS PER HORIZONTAL ROOM WALLS BASE FLOOR CEIL'G PAINTS RESTROOM PAINT SLIDING DOOR TYPE "B". CUSTOM SLIDING ALL STUDIOS W1 B1 F2 Cl P2 COLOR TO BE TEMPERED GLASS DOOR PROVIDED BY ALL CORRIDORS W1 B2 F1 C2 P1,P2,P3 • DETERMINED BY OWNER SOUND WALL. CONTINUE WA L SYMPATECO, INC. 1.800.652.1923. V AND TO ' BREAK ROOM W1/W2 B1 F2 COORDINATE W/ TO EXISTING DEMISING WALL MECHANIC1 P2 CAL, EQUIP. & _ PROVIDE SOUND SEALANT �, 2. TYPE "B" DOORS TO PROVIDE MINIMUM 32" CLOSETS w1 B1 F2 c3 P2 FLOORING, WHERE SOUND WALL MEETS CLEAR OPENING. F2 OR VERIFY W/ - COUNTERTOP, & DEMISING WALL. SEE WALL RESTROOMS W1/T4 C1 F3 OWNER FIXTURES (TYP.) TYPES. (TYP.) 3. ALL HARDWARE FINISHES TO BE 626 SATIN ENTRY AREA W1 B2 F1 C2 P2,P3 J O CHROME FINISH UNLESS NOTED OTHERWISE. CORRIDOR EXIT W1 B2 F1 C2 P1,P3 uix WALL NOTES: P1 4 4 4 4 4. ALL EGRESS DOORS (NEW OR EXISTING) W1 PAINTED GYPSUM WALLBOARD, VERIFY PAINT SCHEME WITH OWNER. a O LEADING TO THE EXTERIOR OF THE BUILDING W2 FRP PANELS. O ARE TO HAVE SIGNS ON THEM STATIN "THIS G " S PAINTING 3 MENS 3 DOOR TO REMAIN UNLOCKED DURING BUSINESS MEC 1. PAINT-SHERWIN WILLIAMS PRODUCT 4 W1 C1 1A 4 HOURS". PROVIDED BY G.C. F2/3 P2 F2 2. PAINT NAME: "DURATION HOME" T4 ' i WOMENS 100" C 1 B1 W1 5. VERIFY THAT ALL LOCK HARDWARE REQUIRING P1 SHERWIN WILLIAMS#SW6125 (CRAFTPAPER)ALTER. IN CORRIDOR W1 Cl C3 VERIFY PLACEMENT WITH OWNER. 1 1 KEYED CYLINDER(S) SHALL BE OF THE TYPE F2/3 T4 0FORMAT 3THAT ACCEPTS INDUSTRY STANDARD "SMALL P2 SHERWIN WILLIAMS#SW6126 (NAVAJO WHITE)ALTER. IN CORRIDOR CERTIFIED BY: BREAK RM. STUDIO 109 INTERCHANGEABLE CORES" (E.G. USE IN ALL STUDIOS& INSIDE OF FRONT WALL&ALL BACK WALLS. 1 P2 F2 ► 1 1 ��1111►11��� O P1 B1 w1 i FALCON ARROW BEST ETC.). CONTRACTOR N P3 SHERWIN WILLIAMS#SW7018 (DOVETAIL)ALTER. IN CORRIDOR. �� •.®� ��i, 3 ° qO C1 1A SHALL INSTALL SAID LOCKS WITH > '��• ' ��cENs' �.p 1 B ; CONTRACTOR'S OWN CORES AND QUANTITY OF P4 SHERWIN WILLIAMS#6488 (GRAND CANAL)SPOT COLOR. CHECK W/® No.KEYS REQUIRED FOR CONTRACTOR PURPOSES OWNER. 60531 STUDIO 108 4 DURINGCONSTRUCTION. 3. VERIFY FINISH ON SOLID DOORS-OPTIONAL PAINT TO MATCH 1� CG Q' 1 ► _ O SURROUNDING WALLS OR STAIN TO MATCH LAMINATE WOOD FINISH. 0 STATE OF 1 1 a 1 4. ALL PAINT TO BE MATTE FINISH. 1 6. COORDINATE ALL LOCKSET FUNCTIONS W/ �,�`�,' •.�OR►pP .••' ��\; OWNER AND INSTA-KEY OR LOCK-SMITH. 6. G.C. TO VERT Y CORRIDOR PAINT SCHEME W/OWNER. /////i®nfAL 3 a a 1 7. G.C. TO VERIFY STUDIO PAINT SCHEMES FOR PRE-LEASED STUDIOS. ,��� ° I 7. TOILET STALL DOORS TO HAVE 1' CUT OFF THE ITOP & BOTTOM OF DOOR. WHEN ORDERING RESTROOM TILE NOTES: 1A P3 1 a i 1 DOORS, REQUEST HINGES TO BE MOVED TO 1. RESTROOM TILE FOR PREMIUM RESTROOMS-VERIFY FINISH WITH OWNER. G.C. TO INSTALL INSULATION IN ALL ® 1 B 1 ; ACCOMMODATE 5' PANEL. T4 12"TILES SET @ A 45 DEGREE ANGLE ON ALL WALLS,48"A.F.F. 1 B WALLS BETWEEN STUDIOS LAUNDRY & ' ® 8. G.C. TO SWING TYPE DOOR W/ GLASS PROVIDE - **NOTE: 48"TILE WAINSCOT STARTS AT FINISHED FLOOR AND EXTENDS O RESTROOMS FOR SOUND PROOFING. STUDIO 111 STUDIO 110 1 STUDIO 107 4 PANEL. FINISH TO MATCH SLIDING DOORS. 48"A.F.F. NO BASE REQUIRED. DRAWN BY: SEE WALL TYPES. ; VERIFY SELECTION W/ OWNER. 4 1 COUNTER-TOP NOTES: KEVIN STUDIO 112 9. SEE DETAIL 22 & 23/A1.4 ON SHEET 1. RESTROOM COUNTER-TOP FOR PREMIUM RESTROOMS SUPPLIED BY SI. 1 1 1 1 A1..4 FOR REQUIREMENTS FOR POCKET DOOR L2 SOLID SURFACE i TYPE "K". CUSTOM SLIDING TEMPERED GLASS 1 O 1 1 1 1 l POCKET DOOR PROVIDED BY SYMPATECO, INC. BASE NOTES: 1.800.652.1923. B1 JOHNSONITE RUBBER BASE K-63 BURNT UMBER. B2 4" SPECTRUM V(30 OZ)QUICK BASE BOUND. COLOR: EBONY DOMINO(#4324) O' I 10. G.C. TO PROVIDE NEW ENTRY DOORS TO MATCH NATIONAL CONTRACT WITH "THE MOHAWK GROUP" EXISTING STOREFRONT - VERIFY HEIGHT. SEE 71" FLOORING CONTACT INFORMATION BELOW. cL SET3 STUDIO 106 4 MATCH/REUSE EXISTING BUILDING HARDWARE. 64 CERAMIC TILE SANITARY COVE BASE WITH MINIMUM RADIUS OF 3/8" VERIFY SELECTION W/ OWNER. ' a B VERIFY FINISH WITH OWNER. 1 P1 Pz N ----- a 1111611 --___ -----_- '� it 11 . G.C. TO INSTALL NEW EXTERIOR DOOR. VERIFY FLOORING NOTES: 1 1 CB O 1 o W/ OWNER. (VERIFY ALL CHOICES WITH OWNER) W F1 MOHAWK CARPET- LEE'S CUSTOM CARPET TI - - U) N LES 50311 G9866 12. G C TO INSTALL COIL TYPE DOOR F N OR W M a 1 INSTALL IN QUARTER TURN PATTERN. NATIONAL CONTRACT CONTACT: BARBARA COATES B � MECHANICAL ROOM. C9 p � J � � ' THE MOHAWK GROUP J Q 4 STUDIO 113 � 1 A � 1 STUDIO 121 STUDIO 120 PH: (800)622-6228 x44051 e�ai ' O I J Q 1 1 �t EMAIL: barbara_coates@mohawkind.com �� STUDIO 105 4 V F2 KARNDEAN DESIGN FLOORING Z Q m 1 1 1 DOOR SCHEDULE STYLE: OPUS Q m _U COLOR: SP214 FORMA STONE (OTHER COLORS AVAILABLE-CONFIRM -3 0 H DOOR DOOR LOCKSET CHOICE W/SOLA CORPORATE) Q Z Q WIDTH HGT. REMARKS NATIONAL CONTRACT CONTACT: REMO MARTI Q J 1 1 1 1 1 1 SYM. THK TYP MAT'L FUNCTION TOTAL FLOORS, INC. CO) J F- Q Q 3'-0" 7'-0" 1 X. 1 WOOD PASSAGE - 640 W. TENNESSEE AVE. � 1Azzzzzzz= DENVER, CO 80223 i1 B - - - - - - NOTE #1 PH: (303) 596-3448 j 2'-0" 7'-0" 1 X" 1 WOOD CLOSET - FAX: (303) 722-5913 0 STUDIO 114 j - j D 3'-0" 7'-0" - - - - NOTE#11 EMAIL: remo@totalfloors.biz ® STUDIO 122 STUDIO 119 i 1 QE 3'-0" 7'-0" 1 X" 1 WOOD PRIVACY NOTE #7 F3 CERAMIC TILE FOR PREMIUM RESTROOMS. VERIFY FINISH WITH 1 B CB i F 4'-0" 7'-0" 1 X" 1 WOOD CLOSET NOTE#12 OWNER. �1 11 STUDIO 104 4 © 2'-8" 7'-0" 1 X" 1 WOOD PRIVACY NOTE#7 CEILING NOTES: "' 1 ► OB Q 3'-0" 7'-0" - 2 ALUM OFFICE NOTE#8 a a 1 a I I " s _ Cl USG#2852 RADAR CLIMAPLUS ILLUSION 8/12 WITH WHITE GRID. 1 Q 3-0 7-0 1 /4 1 WOOD PRIVACY N it 1 WOOD 0 2'-6" 7'-0" 1 X" PRIVACY - SEE SHEET A1.6 FOR CEILING HEIGHTS. a n`". a 1 ;i Q VARIES 7'=01 - - - - NOTE #9 C2 GALVANIZED AMERCAN DCORRUGATED E AD RO FORMING SHERRI WANDELL 916-652-7667 © PR 6-0 VERIFY - - - - NOTE#10 1 1 ; 1 (VERIFY, sherri@americandieandroliforming.com B ® 1 NOTE: VERIFY LOCKSET FUNCTION SPECIFIED FOR RESTROOMS MEETS LOCAL CODE. CONFIRM WITH OWNER 26 GUAGE (2 1/2"X%") GALVANIZED (G-90)B a 1 STUDIO 115 B IF"CLOSET" LOCKSET ARE DESIRED ON DOORS LISTED. COORDINATE DESIRED KEYING REQUIREMENTS. PANEL SIZE 2.67 FT.X 2.67 FT. 1 1 � 4 1 j STUDIO 123 STUDIO 118 USE USG CEILING GRID--COLOR:CHROME 1 i SEE SHEET A1.6 FOR CEILING HEIGHTS. 1 � 1 ALLOW 2 WEEKS MINIMUM FOR DELIVERY. � I O ' C3 GYPSUM WALLBOARD TO BE PAINTED TO MATCH SURROUNDING 1 1 1 1 1 WALLS. � STUDIO 103 5 **NOTE: PAINT ALL CEILING VENTS & REGISTERS TO MATCH SURROUNDING 1 CEILING TILE. I 1 I K � TEMPERED GLASS, USE INSULATED TEMPERED GLASS O N TEMP GLASS EXTERIOR DOOR X zvaxnat a. II @ S _ PARTITION SCHEDULE 5 i P1 ----- ---- ------ ---- ----- P2 --------- i' VARIES 6.. 2._ 6„ VARIES "'�� SYMBOL DESCRIPTION O 1 1 O K 1 (01 TYPICAL INTERIOR WALL ASSEMBLY: 511 " I /O % 1 20 GA 3 x 1 1, MTL STUDS @ 16 O.C. W/%a PTD GWB EACH SIDE. FILL CAVITIES WITH 00 / O R-11 INSUL. BATTS (AS INDICATED ON PLAN). PROVIDE KICKERS TO STRUCTURE AS STUDIO 116 ioo 00 62 LiJ U-1 NECESSARY. 00 -J J F1 - 1A SAME AS TYPE 1, BUT WITH 6" METAL STUDS. UTILIZE R-19 INSULATION. HAYNES CHIDSEY C2 w o -w OWNER STUDIO 117 W1 YP. STUDIO 101 STUDIO 102 U - LO U SAME AS TYPE 1 OR 1A, BUILD TO DECK W/ONE(1) LAYER OF QUIET ROCK GWB. ON 1 1 1 1 5 U) U) 0 STUDIO/HALLWAY SIDE AND TWO (2) LAYERS OF GWB ON RESTROOM/BREAK ROOM BUS.: 704.900.7730 w P2 it tw O SIDE FOR NOISE REDUCTION. INCREASE STUD GAUGE AS NECESSARY FOR STABILITY. CEL.: 303.881 .7314 o GWB TO BE WATER RESISTANT IN RESTROOMS. USE SOUND SEALANT AT BASE OF B1 STUDS, BOTH SIDES. SOUND SEAL ALL PENETRATIONS. F2 C1 4 EXISTING WALL FURRED-OUT W/ 20 GA 6" x 1 Y" MTL STUDS W/%" GWB. P2 TYP. O' EXISTING WALL FURRED-OUT W/ 20 GA 3 5/8" x 1 Y" MTL STUDS W/%" GWB. L O O O GENERAL PARTITION NOTES: "X" INDICATES CHANGE O ry '�/ 1. THE EXISTING DEMISING WALL(S) MAY BE A RATED ASSEMBLY-U.L. THIS PARTITION IS REQUIRED TO IN PAINT COLOR (TYP) DOOR TYPES PES PROVIDE A CONTINUOUS MINIMUM SEPARATION FROM TENANT SPACE TO ALL ADJACENT PROJECT: 1 SPACES. GC TO VERIFY RATING OF PARTITION ABOVE CORRIDOR CEILING AND MAINTAIN RATING AS SL-FL-253 SCALE: 3/811 = 1'-0" NECESSARY. ATLANTIC VILLAGE CARPET TILE TO CUT TO FIT IN 2. PARTITION SUPPORT KICKERS ARE NOT TO BE VISIBLE FROM HALLWAYS AND OTHER PUBLIC SPACES. CORRIDORS FOR BEST UTILIZATION RELEASE DATE 3. ALL WALL SHALL EXTEND 6"ABOVE DESIGNATED CEILING HEIGHT UNLESS NOTED OTHERWISE. 04/02/14 REVISIONS: 1 BLDG. DEPT. REVIEW-5/23/2014 FINISH PLAN SCALE: 1/4"=1'-0" DRAWING NAME FINISH PLAN & SCHEDULES FINISH PLAN & SCHEDULES N SHEET NO. A1 . 3 It li Ili i WELD TUBE I 0 PLATE SEE SYMPATECO MANUAL FOR TYPICAL DOOR HANDLES & LOCK 600 ANGLES I INFORMATION. ADDTIONAL OPTIONS ARE AVAILABLE UPON REQUEST. 16" — TOP OF TYPICAL INTERIOR PARTITION 12" 4" • LINE OF FINISHED CEILING 0° Z WITHIN STUDIO SPACES 27 CENTER STUDIO AREA OF SOLID BLOCKING \ 1 FT STL CHANNEL (2) 2x4 WOOD SEE SYMPATECO MANUAL FOR TYPICAL DOOR FSIGNAGE ABOVE DOOR YP.) FOR SIGNAGE IN WELDED TO TUBE STUD HEADER HANDLES & LOCK INFORMATION. ADDITIONAL ( CORRIDOR (TYP. OF 2) OPTIONS ARE AVAILABLE UPON REQUEST. DRYWALL TO N. -- -- - ---- --- -- -- ---- - __ � COVER FRAMING KEEP DRY!WALL SCEWS 12"AWAY FROM HEADER PAINTED GWB �.I OPENING BECAUSE THEY CAN "POP"WHEN DOOR 00 2x3 TUBE =N __ IS INSTALLED. lLIa SLICED (2) 2x4 STUDS %41 _ _ _ DOOR ASSEMBLY CONSISTS OF ONE FIXED AS SHO OIL DOOR AND ONE SLIDING DOOR SUSPENDED ON N O1 TRACK-SUSPENDED DOOR IS SUPPORTED BY U VERIFY EXACT SCONCE C V RIFY EXACT SCONCE (C) DOOR FRAME FIXED PANEL. p� LOCATION WITH OWNERS ) LOCATION WITH OWNERS 12" 0 x%2" THICK SEE DETAIL OF CRITICAL:ROUGH OPENING �N W SIGN CORNER FRAMING SIZE 76�°WIDE x 86 d (SEE ALSO A1.6) (SEE ALSO A1 .6) (BY OTHERS) (2) 2x4 STUDS Z r (2) 2x4 WOOD HEADER r III LID a ° /// / 2s TWO DOOR HOOKS � _ � ❑ CERTIFIED BY: o0 00 J _ - PER SLIDING DOOR _ ° w C) CO G.C. TO INSTALL ON ° D. 29L 99 FIXED GLASS SIDE z `����,` E ....... LOWES BRAINERD #66326 . W -d (2) 2x4 STUDS :�Q ��CENS�•.,.�o'� BRUSH NICKEL o ° o ..... .,.: _ / _ N • 60531 – ;,.: 00 0 DRYWALL o 11 WHEN FRAMING,GC TO RUN 1 CONTINUOUS SOLID ` � BASEPLATE THROUGH OPENING 75� CRITICAL:ROUGH OPENING BLOCKING WITHIN WALLS WOOD STUDS ° DRYWALL TO COVER �'n srgTEOF •�••�/�� OVERALL DOOR FRAME SIZE 76%"WIDE x 86%"HIGH WELD TUBE TO PLATE 1 • -..0 !v\� FROM SIDE TO SIDE AND ENSURE I AS NOTED . . FRAMING EACH SIDE �,e�S'S;' •.. R... ..•• g�`� PROPER ALIGNMENT OF OPENING 763 G.C.TO MAKE CEILING HEIGHT SCONCE SIDE VIEW / DRYWALL / SEE DETAIL ��o�IAL �G`�� AS HIGH AS POSSIBLE. 2x3 TUBE SLICED AS SHOWN �' ��i►i++�+��`� FOR DOOR FRAME. ROUGH OPENING (VERIFY WITH OWNER) 3 „ +r 1 � 0 ,x 31 LONG LAG BOLTS ROUGH OPENING IS FRAMED WITH 2 2x4 WOOD STUDS DRYWALL 75Y" NO DOOR THRESHOLD CUSTOM SLIDING TEMPERED GLASS DOOR- PROVIDED BY SYMPATECO, ; 411 x 4 x/$ STEEL PLATE W/ OVERALL DOOR FRAME ON DOOR FRAME NATURAL BRUSHED FINISH (I.E. CG EDGE OF STUDS SHOULD BE FLUSH WITH THE DRYWALL INC. 1.800.652.1923 TO RANDONLY HIT PLATES W/ AND CARE SHOULD BE TAKEN TO MAKE SURE THAT THE 763 " STEEL BRUSH SANDER OR SIM.) DRYWALL IS SQUARE AND PLUMB. ROUGH OPENING 75%" W x 85Y4H FRAME SIZE- VERIFY 32" CLEAR OPENING WITH NO - ' THRESHOLD. FINISH TO STANDARD CLEAR ANODIZED ALUMINUM. °r° 2ND CHANNEL SHOW DASHED FOR CLARITY DRAWN BY: j] ! FRAMING DETAIL OF DOORWAY SLIDING DOOR ELEVATION NOTE: EACH PAIR OF DOORS TO BE KEYED DIFFERENTLY. KEYS TO BE 12" 0 x%" THICK SIGN KEVIN RE-KEYED LOCALLY AFTER INSTALLATION & PROVIDE MASTER KEY FOR BY OTHERS SIDES FOR SLIDING DOORS NOTE: DOOR ASSEMBLY PROVIDED WITH TEMPERED GLASS OWNER. ALLOW 6 WEEKS MIN. TO ORDER. VERIFY ROUGH OPENING CONTINUOUS SOLID BLOCKING WITH MFA. WITHIN WALLS AS NOTED SEE ALSO DETAIL 3/A1.4, I; SIGNAGE PRq IDED BY SYMPATECO INC. I 1 TYPICAL INTERIOR ELEVATION Ue2;-�_TYPICAL SIG; AGE DETAILS TYPICAL SLIDING DOOR DETAILS SCALE: 3/8" = 1'-0" SCALE: 2" = 1'0" N Q� I r �" " W 1/ H 77 72 24" LOGO ATTACHED TO WALL ``' 48/8" 42Y" = N GEN. CONTRACTOR GEN. CONTRACTOR WITH STAND-OFFS. SLATWALLANIBLKG SLATWALLANDBLKG Lu Co M BLKG� TO PROVIDE 2x6 3u 3u TO PROVIDE 2x6 i SEE PLAN FOR LOCATION OF LOGO J CENTER SLATWALL BLKG�M CENTER SLATWALL J d _j BLOCKING IN WALL // / GEN. CONTRACTOR BLOCKING IN WALL FOR = Q = ABOVE MIXING J Q = FOR INSTALLATION / GEN. CONTRACTOR TO SALON c0 5 ABOVE MIXING CABINET C.0 7 r > (MIRROR) (MIRROR) TO PROVIDE 2x6 INSTALLATION OF 9 M� M CABINET o > W v OF CABINETRY CORNER UNIT SLATWALL & CABINETRY (MIRROR) CORNER UNIT PROVIDE 2x6 BLOCKING g BLOCKING IN WALL fl � v w WITH SINK / / WITH SINK IN WALL FOR INSTALLATION BLKG �- O m // _ FOR INSTALLATION BLKG Z 36 E1 48" _ E1 36 OF TALL RECEPTION SHELF _ - Q m V 36 - OF CABINETRY 36 ❑❑ GEN. CONTRACTOR LO GEN. CONTRACTOR �, J v H 0O BLKG 00 c� TO PROVIDE 2x6 ao TO PROVIDE 2x6 ' Q Z Q _ BLKG BLOCKING IN WALL _ BLKG BLOCKING IN WALL Q J 6) _ FOR INSTALLATION OF _ FOR INSTALLATION Oo Q _ O t It 17 I _ ' _ I I i I d �W - — I I — SLATWALL & CABINETRY W _ I I — OF SLATWALL & co M 1820 oM M M 18 19 20 co Q M 10 84 92 a M 15L 38L v- 1191❑ ❑ ❑ ❑ I M 0 — — — �� — — CABINETRY (TYP.) o 4- J s N I I t:::i I CABINET BLKG 4 LEFT VIEW CORNER UNIT 5 RIGHT VIEW CORNER UNIT 6 18/19/20 WINDOW STYLING UNIT 7 25 DISPLAY SHELF 8 10/84/92 COLOR BAR / 5 SLATWALL 9 15L/38L COLOR BAR / 7 SLATWALL SCALE: 3/8" = V-0" ( SCALE: 3/8" = 1'-0" SCALE: 3/8" = 1'-0" ` GALE: 3/8" =1'0" GEN. CONTRACTOR TO PROVIDE 2x6 GEN. CONTRACTOR GEN. CONT CTOR 25�" S AN ALL TO PROVIDE 2x6 �/ TO PROVID . 2x6 BLOCKING IN WALL CABINET BLOCKING 5411 LI`�Yrs" co „ CABINET KING IN WALL rSLA�WALLANDBLKG M BLOCKING I WALL 45„ FOR INSTALLATION OF 24• 241/" �� FORCINSTALLATION OF ETRYANDBLKG SLATWALL & CABINETRY BLKG 52 CENTER FOR INSTAL ATION OF ,�_ CABINETRY (TYP.) BLKG BLKG BLKG SLATWALL ABOVE Ja CABINETRY TYP.) .N W BLKG BLKG BLKG BLKG MIXING CABINET 7 Q N m 22u - GEN. CONTRACTOR d s N 0 0 0 1 0 1 ( GEN. CONTRACTOR M 4 90 N g co 10101 I I I TO PROVIDE 2x6 GEN. CONTRACTOR TO PROVIDE 2x6 TO PROVIDE 2x6KING IN WALL �BLKG - - BLKG „ 22s _ 1 BLOCKING IN WALL - - GEN. CONTRACTOR GEN. CONTRACTOR N _ ❑ 04 BLKG BORCINSTALLATION OF Nt _ 34 L Y ❑ W FOR INSTALLATION OF TO PROVIDE 2x6 TO PROVIDE 2x10 N � - Z N OR SLATWALL. N BLOCKING IN WALL 0EO �o N _ Q e0 L0 00 BLKG IN WALL FOR B 3G 0O < 00 ❑ TALL STORAGE CABINET. 000 FOR INSTALLATIONBLOCKING IN WALL OF SLATWALL & gBLKG - � �B�LKGJ— = BLKG INSTALLATION OF COUNTER rt BLKG = rn FOR INSTALLATION OF _ a _ _ _ BLKG W CABINETRY TYP. — I I _ �d �t� I I — _ _ o - M - x TVD100 (TYP.) 38R 15R o zv -K 0 1009 SLATWALL & CABINETRY o — 37 o iv W z I I - - M a co cfl< M — — M — _ TAPERED SUPPORT �- M Z mFn 00 22B N BLKG M I ❑ M ` ``' ``' — CLEATS TO WALL 3 0 ❑ ( co CABIN5^ND BLK G J'i� 11 i 15R/38R COLOR BAR /.7SLATWALL 1009 COLOR BAR / 1010 UPPER 37 DOUBLE DRAWER STACK / 8 SLATWALL 74 STYLING COUNTER SHELF 22 SHAMPOO UNIT 1 / 2 TALL STORAGE &SC! 17 8LSCALSCAL : 312 SCALE: 3/8"= 1'0" 13SCALE: 3/8"= 1'0" j SCALE: 3/8"= 1'-0" 15 SCALE: 3/8" = 1'-0' : 3/8" = 1'-0" SCALE: HAYNES CHIDSEY (2) 2x6 STUDS 82y8" (2) 2x6 STUDS OWNER BUS.. 704.900.7730 2X6 STUD-TO-STUD 2X6 (I BOTTOM PLATE BOTTOM PLATE CEL.: 303.881 .7314 PLAN I, PLAN VIEW CRITICAL:ROUGH OPENING VI I' �A� 1X4 „ „ DRYWALL „ „ A� „ 1 X4 DRYWALL SIZE 49 2"WIDE x 49 y"HIGH 6 6 L. I 1611 .IL 6 6 �,� I �I' 16 •� WOOD STUDn n WOOD STUD ,� 28�" 42" M GEN. CONTRACTOR DRI ALL I DRYWALL TO PROVIDE 2x6 Z DRYWALL TO COVER -- N BLOCKING IN WALL a FRAMING EACH SIDE 4u I I I i ; PROJECT: FOR INSTALLATION OF m ? OF WALL BUT NOT �� (2) 2x6 HEADI RS 601 „ (2) 2x6 HEADERS = SL-FL-253 CABINETRY (TYP.) OPENING 32xb ,44 M I ATLANTIC VILLAGE N N I � I 41 1/2" ao q R co— GEN. CONTRACTOR �F I RELEASE DATE WOOD STUDJo' 49/2' TO PROVIDE 2x6 �BLKG �� $2e" 04/02/14 � BLOCKING IN WALL STUD-TO-STUD ANGLE TO HOLD 1x4, I STUD-To-STUD ANGLE TO HOLD 1x4, co N _ DRYWALL ROUGH OPENING 3sR 15R o co ANGLE NOT LARGER REVISIONS: FOR INSTALLATION — M �m EDGE OF 2x4 S' UD I EDGE OF 2x4 STUD I ANGLE NOT LARGER B3"KG B 2" co OF CABINETRY (TYP.) — �' THAN 1-1/4 x 1-1/4 -116— L THAN 1-1/4 x 1-1/4 1 BLDG. DEPT. REVIEW-5/23/2014 I' , ti START OF ANGLE TO HOLD END VIEW SECTION ,,A , START OF ANGLE TO HOLD END VIEW SECTION EDGE OF 1x4 SI PPORT `p=' 1x4 DRYWALL BRACES CORRIDOR STUDIO EDGE OF 1x4 SUPPORT `A' 1x4 DRYWALL BRACES CORRIDOR STUDIO ~ 34L RESTROOM COUNTER 54 INT. STUDIO WINDOW 32 FREE STANDING DISPLAY 38N 15R COLOR BA / 94 UPPER SIDE SIDE SIDE SIDE 18 SCALE: 3/8" = V-0" 19 SCALE: 3/8"= 1'-0" 20 SCALE: 3/8"= 1'-0" 21 SCA /8"= 1'o" I CORRIDOR SIDE LOOKING INTO STUDIO CORRIDOR SIDE LOOKING INTO STUDIO *NOTE: DOOR ASSEMBLY PROVIDED WITH TEMPERED *NOTE: DOOR ASSEMBLY PROVIDED WITH TEMPERED SEE ADDITISYMPAONAL IN MANUAL FOR GLASS. (SEE MANUAL DETAIL PAGES) GLASS. (SEE MANUAL DETAIL PAGES) DRAWING NAME ADDITIONAL WINDOW INFORMATION. SEE SYMPATECO MANUAL FOR TYPICAL DOOR SEE SYMPATECO MANUAL FOR TYPICAL DOOR DETAILS & NOTES DETAILS & NOTES HANDLES & LOCKS INFORMATION. HANDLES & LOCKS INFORMATION. SHEET NO. ADDITIONAL OPTIONS ARE AVAILABLE UPON REQUEST. ADDITIONAL OPTIONS ARE AVAILABLE :UPON REQUEST. n87R DOOR DETAIL 23 89R DOOR DETAIL A 1 . 4 SCALE: 3 8"- V-0" SCALE. 3/8 1 0 / ELECTRICAL LEGEND ELECTRICAL NOTES DUPLEX - 120V- 15-20 AMP - HEIGHT BY CODE MCI:A UNLESS NOTED OTHERWISE ON PLAN. 1 . ALL WORK SHALL CONFORM TO APPLICABLE FEDERAL, GFCI AS REQUIRED BY CODE STATE AND LOCAL CODES. QUAD - 120V -20 AMP - 24" AFF O.C. (IN CABINET) 2. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY RY PERMI T S • UNLESS NOTED OTHERWISE. B OUTLETS ARE NOT AND SHALL PAY ALL REQUIRED FEES FOR THIS WORK. SWITCHED. GFCI AS REQUIRED BY CODE. — MIRROR MIRROR WALL DUPLEX OUTLET TO BE ELECTRICIAN TO PROVIDE EACH / 3. THE CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS STUDIO WITH A TELE. JACK II 3 -GANG -120V -20 AMP - 3 DUPLEX OUTLETS AND REPORT TO SYMPATECO, INC., IN WRITING /TELEPHONE: LOCATED IN CABINET REARWALL ELECTRICIAN TO LEAVE 3'-0" FLEX @ 24" AFF 2 LOCATED IN CAB. REAR WALL OPENING ili 1-800-652-1923, ANY DISCREPANCIES IMMEDIATELY UPON OPENING- VERIFY W/ OWNER / C FOR HOOK K UP TO OUTLET. OUTLET, BOX, WIRING DISCOVERY. —� WALL QUAD OUTLET TO BE 36 LONG ELECT. FLEX FROM WALL 74 & CO PLATE BY ELECTRICIAN. GFCI AS REQUIRED LOCATED IN CAB. REAR WALL @ 24" AFF FOR HOOKUP TO 3 GANG BY CODE. OUTLET TO BE SWITCHED AS ALLOWED BY 4. UNLESS OTHERWISE NOTED, ALL TELEPHONE, ELECTRICAL, LV Z OPENING OUTLET IN CAB. TOOL PANEL WALL QUAD OUTLET CODE - PROVIDED BY ELECTRICIAN, SEE OWNER. ONE CABLE & DATA LINE OUTLETS SHALL BE LOCATED 18" ABOVE THE I I WALL DUPLEX OUTLET ® DEDICATED "C" OUTLET PER CIRCUIT. FINISHED FLOOR. I ' II I V� 1 s OR I I 17 I �, 19 1 20 ® D DUPLEX - 120V- 15-20 AMP - 24 AFF O.C. UNLESS 5. UNLESS OTHERWISE NOTED, DIMENSIONS FOR ALL NEW WORK 8 I� NOTED OTHERWISE. GFCI AS REQUIRED BY CODE. ARE MEASURED FROM FACE OF GYPSUM BOARD. DIMENSIONS WALL WALL DUPLEX - 120V- 15-20 AMP - SWITCHED OUTLET TO REFERRING TO EXISTING WORK ARE MEASURED FROM FACE OF he So =4E BE INSTALLED ON WALL @ 6" AFF AS NEAR TO EXISTING FINISH. 74 STYLING UNIT FLOOR AS POSSIBLE. SWITCH TO LIGHT SWITCH. 5 SCALE: 3/8" = 1'-a' 6. ALL ELECTRICAL DIMENSIONS ARE TO CENTER-LINE. ALL 'HOLD' CERTIFIED BY: 18/19/20 CORNER UNIT 17 CORNER UNIT 1 2 $ � ��t D. �/ LIGHT SWITCH DIMENSIONS ARE CRITICAL. *' '�/``�� `Ca .. •••••. o� PROPOSED NEW '��'5 �ICErasF• ,p® ' ELECTRICAL PANELS Q TELEPHONE - (TYP.) CAT3 CABLING. 24" AFF O.C. 7. CHECK WITH OWNER RE: LOCATION OF TELEPHONE AND ALARM LOCATION UNLESS NOTED OTHERWISE. SYSTEM. ELECTRICIAN TO PROVIDE OUTLETS FOR THE DOOR / �O' 6p$31 i _ -o �r CAMERA SYSTEM AND DVD PLAYER. ELECTRICIAN TO CONTACT CABLE TV OUTLET - _. - TELEPHONE CO. TO VERIFY THE NUMBER OF LINES COMING INTO Oma'. EXIT CTAT OF �/ A F_----_1 A- A- THE BUILDING. PHONE LINE REQUIRED TO EACH STUDIO FROM ° �c - SECURITY CAMERAS SEE ELECTRICAL NOTES .000, }� q_ I 90 13 ( ) CENTRAL PHONE BLOCK. CLEARLY MARK STUDIOS ON PHONE ``,S�C'��,L O /-\\-; `-#' REF'J 7 A __ CEILING MOUNT TV'S - 21" SILVER/GRAY-CHECK WITH BLOCK FOR EASE OF CONNECTION UPON STUDIO RENTAL. �`'��rlrl A- -- EQUIP. Ne=__7 CHECK WITH OWNER FOR NUMBER OF LINES. CONSULT SOLA 35" 3 MECH OWNER RUN CABLE TO DVD PLAYER LOCATED IN MENS _ DEVELOPMENT MANUAL FOR ADDITIONAL DETAILS, SPECS AND w/ LAUNDRY OR STORAGE ROOM PROVIDE CAN OUTLET L--- J ��_ INFORMATION. ---- �' - N; - A AND 120V. CEILING MOUNTED RECEPTACLES. W/D A ❑ ASG 5 U� �N 6 8. ALL VISIBLE OUTLET COVERS TO BE STAINLESS STEEL. ALL `__ - - 00 p" STUDIO 109 A OUTLET PLATES IN CABINETS AND NOT VISIBLE TO BE WHITE. WOMENS q - D:0 A i 9. G.C. / ELECTRICIAN TO PROVIDE AND WIRE EACH STUDIO WITH DRAWN BY: 4 TELEPHONES. TO BE INSTALLED AND COMPLETED FROM EACH KEVIN '-10" ' _ STUDIO TO REAR OF STORE. G.C. TO LABEL ALL BREAKER AND ELECTRICAL KEY'D NOTES TELEPHONE PANELS. BREAK RM. / e I ; i ; STUDIO 108 D::Dr 4.113-18" _ `��"" ' 10. ELECTRICIAN TO PROVIDE CONNECTION TO WATER HEATER � � � ❑ TELEPHONE KEYPAD AT FRONT ENTRANCE. CARD READER AT A E GF I �;1 / �® FRONT DOOR. IGNITOR. A- A- A A- A- e--- i l A- 5._ 8❑ or 45, o ❑ GFCI ❑ ELECTRICIAN TO CHECK WITH OWNER REGARDING ANY 11 . ELECTRICIAN TO PROVIDE CONNECTION TO STACKED 6" 9®v Z_' �'� _ 6�� C i 11 9 2 ADDITIONAL OUTLETS FOR WINDOW SIGNAGE AND LOCATION OF WASHER/DRYER UNIT, CONFIRM THE POWER REQUIREMENTS A _ ; ; r A- 5'_ SIGNAGE. W/ MANUFACTURER. SEE INSTALLATION MANUAL. GFCI -1 i i 3 12. G.C. TO VERIFY SECURITY CAMERA LOCATIONS AND MOUNTING r A STUDIO 110 r —® col 3 G.C. TO PROVIDE AND INSTALL 4 HP IN-SINK-ERATOR GARBAGE \ 21-511 1 1 1 ` HEIGHT WITH OWNER PRIOR TO INSTALLATION. _ 1 1 10 DISPOSAL, PROVIDE SWITCH. SEE SHEET A1.7 FOR LOCATION OF rn ` `♦ i i SINK. SEE SHEET A1 .4 FOR HEIGHT OF COUNTER. e___ Tv STUDIO 111 ( - I , 1 13. ELECTRICIAN TO PROVIDE 40 AMPS TOTAL TO EACH STANDARD M STUDIO 107 OR LARGE STUDIO (TWO 20 AMP CIRCUITS). ONE CIRCUIT IS N ❑ , - ___ _ 00 _ WALL MOUNTED TV OPT'L COORDINATE ALL REQUIREMENTS W/ w cn M '� ❑ OWNER INCLUDINGM ) DEDICATED TO OUTLET "C". DOUBLE STUDIOS REQUIRE 80 AMPS / q GFCI 0 MOUNTING HEIGHT AND LOCATION. PROVIDE C� p STUDIO 112 \ A- co A ALL NECESSARY POWER, MOUNTING & CABLING NEEDED TO (FOUR 20 AMP CIRCUITS). J Q u- GFCI A INTERFACE W/ SECURITY SYSTEM. rn > w v \ GF I 14. G.C. TO INSTALL TELEVISIONS WITH CEILING MOUNTING 0 �e A BRACKETS AND CABLING. VERIFY WITH OWNER. CABLES TO V 5 W A p 5 SEE SOLA DEVELOPMENT MANUAL PROVIDED BY SYMPATECO, �-- p m ------ ----- INC. FOR INFORMATION ON WASHER/DRYER. PROVIDE 30-AMP RUN TO DVD PLAYER IN THE LAUNDRY OR STORAGE ROOM. ZZ m v - ------ ----- THREE TV'S PER CORRIDOR OR AS INDICATED. ELECTRICIAN TO I� J U P OUTLET (OR AS REQ. PER MANF. RECOMMENDATIONS) PROVIDE OUTLETS. G.C. TO RUN CABLE FROM EQUIP. CLOSET ~ I- Z I ' TO ALL STUDIOS AND TIE UP ABOVE STUDIO CEILINGS. LABEL z B Q CLOSET ' ', STUDIO 106 6 3 QUAD OUTLETS ALIGNED VERTICALLY @ 48", 60", & 72" AFF j \ i i i 1 ❑ OPTIONAL IF CLOSET USED FOR EQUIPMENT. COORDINATE EACH LINE WITH STUDIO NUMBER. Q Q GFCI ' I 1 / `� LOCATION WITH OWNER. N ems✓ ---- ---- i i / ? '- - q_ ----_ -_____�- -______- _---- q_ i ` A- 7 G.C. / ELECT. TO VERIFY ELECT. REQUIREMENTS FOR WATER GFCI � GFCI A GFCI GFCI 5-6 ❑ \� � � A , HEATERS ��` �1 q_ 5'_ ® G.C. / ELECT. TO VERIFY ELECT. REQUIREMENTS FOR ELECTRIC GFCI STUDIO 113 WATER COOLER W/ MFA. 1 1 STUDIO 121 1 1 STUDIO 120 ' 1 �� ❑g CEILING MOUNT RECEPTACLE FOR TV'S. SEE A1.6 FOR CEILING ' q / _ A HEIGHT. COORDINATE FINAL LOCATIONS AND QUANTITIES WITH 3'-8" C 5'- ` < "- " 3'-8" STUDIO 105 `®_ OWNER. I A A p1� 9 - Fl-0] PROVIDE OUTLETS INSIDE CABINET. PROVIDE FLEX FROM _ A q A PERPENDICULAR WALLS TO BE RUN THROUGH CABINETS. gp" 90" - °O o 90 A 11 ELECTRICIAN TO BRING WIRING ALONG STOREFRONT OR STUDIO 114 , - A ❑ EXISTING WALL. IF SURFACE CONDUIT REQ'D., CONFIRM WITH ---�`` �'► ' 11 r'_ --�` STUDIO 119 ; r OWNER TYP. 11 1 ► 1 CV '1 1 STUDIO 122 1 j ' I ' i 1 _ _ i 1� ; = 12 ELECTRICIAN TO PROVIDE FLEX FROM PERPENDICULAR WALLS ' ' FOR SURFACE MOUNT OUTLETS IN STYLING CABINETS ALONG ; / \ y111% ; -1 STUDIO 104 1 REFERENCE ELEVATIONS FOR 1 1 C r 1 1 A1.5 THE WINDOW WALL TO BE RUN THROUGH CABINETS. SEE i r 1 1 / „ ► _ CORNER STUDIOS ONLY (TYP) GF I 1 1 A- 5-6 5 ♦ lilt L III, /� �,, 2 LEGEND FOR TYPE OF OUTLETS C=a�]N G C I G F I e_ —]N ; i / A1.5 ® x TVa:o. " - _ _�Tv e___7Tv 13 PROVIDE NECESSARY ELECT. TRANSFORMER FOR MECHANICAL & FCI ; 9 5'- X '- FCI 1 1 9❑ ' 't GFCI 5' EQUIPMENT. COORDINATE W/ OWNER '_4 1/2" ' ` � ����` � ' _ _ _ �Ap 14 STUDIO GFCI OUTLET TO BE EASILY ACCESSIBLE FOR STYLIST 1 1 r \ �� ► i GFCI AFF 2 j-4'' TO RESET IF NEEDED - DO NOT LOCATE ABOVE TALL STORAGE STUDIO 115 1 ► 1 1 1 ' tit \ \ STUDIO 118 co ; ; ��/�'®� i A OR IN CABINET. PROVIDE TWO GFCI OUTLETS IN DOUBLE 1 1 STUDIO 123 (; 1 1 � 1 � STUDIO'S. (TYP.) ' 00 - ' ' HAYNES CHIDSEY gp° A- A A ; OWNER 9011 q q STUDIO 103 �r- BUS.. 704.900.7730 q_ - ,45' GFCI e_ _ 9(-0-4 / 7'-pll © N0 / I 1 ®/ / 21_61' 51_ It r�� I I / � it ------ ----- -------- 02 /� � q_ A- A- A q GFCI GFCI 5 p GFCI \` 14 GFCI\`\ / STUDIO 117 '/ I PROJECT: SL-FL-253 REFERENCE ELEVATIONS _ /�� ' i' _ 4 / ', ATLANTIC VILLAGE FOR EURO STYUDIOS ONLY (TYP) B 18 o� q_ / / I AlF� ��� STUDIO 116 GFCI 111 A1.5 B F j �� _ iic-- RELEASE DATE / / e 04/02/14 4 „ STUDIO 101 / STUDIO 102 `` E REVISIONS: 9011 / / I 1 BLDG. DEPT. REVIEW-5/23/2014 10, A F - E _ `� - c� !I 90, Lo M 1 � I A 11 = 00 ENTRY ELECTRICAL LAYOUT SCALE: 1/4"=1'-0" DRAWING NAME ELECTRICAL LAYOUT & DETAILS ELECTRICAL LAYOUT& DETAILS N SHEET NO. Al . 5 i HVAC NOTES 1. EACH STANDARD AND LARGE STUDIO TO HAVE 1 DIFFUSER AND 1 AIR RETURN. MENS 2. EACH DOUBLE STUDIO TO HAVE 2 IIICEILING SPEAKER - DIFFUSERS AND 2 AIR RETURNS. CEILING @ SEE LEGEND V CEILING SPEAKER - 9'-6"AFF 3. HVAC DIFFUSERS TO BE LOCATED AWAY Z SEE LEGEND FROM STYLING STATION/CHAIR TO ------- PREVENT DIRECT AIRFLOW ON CUSTOMER. DIFFUSER TO HAVE ExIT MANUAL CONTROL FOR ADJUSTING —j A - A 04A F AIRFLOW.q q N Wi MECH. 4. G.C. TO VERIFY AND COORDINATE ALL c 8 rn M WOMENS CN EQUIP' CEILING @ MECHANICAL SHAFT AND DUCT q A O a'o"AFF LOCATIONS. oj CEILING @ _ STU 10 109 CEILING Ga 9'6"AFFi / -�8" © BREAK RM. 8'-0"AFF; O A A A = I' A 5. G8 .C. TO PROVIDE MINIMUM OF TWO M �I' lei REMOTE THERMOSTAT SENSORS TO BE ®F �`' LOCATED IN EACH STUDIO. VERIFY c WITH OWNER. A 9 '-o° CERTIFIED BY: c _ A LIGHTING NOTES e� '�� c®Nyol� ' s O � Act 1 . ALL WORK TO STRICTLY COMPLY WITH y � :� No. 60531 = Lu ALL FEDERAL, STATE & LOCAL CODES. STUD O 108 �® (t 2. OWNER TO VERIFY WITH LANDLORD IF �� ' STATE°F •''•4i�� EXTERIOR SIGNS ARE ON COMMON '%�S�;,j'��RIDP .• C) N ELECTRIC CIRCUIT FOR BUILDING OR TO BE ON SOLA CONTROLLED TIMER LOCATED IN EQUIPMENT # 2. !­ C(l c 3. CORRIDOR LIGHTS AND SCONCES TO BE ON A TIMER. OVERRIDE SWITCHES AT ENTRANCES. STUDI 111 LT�U10110 N STUDIO 112 4. G.C. TO PROVIDE EXIT SIGNS, FIRE DRAWN BY: STUD 0 107 EXTINGUISHERS, EMERGENCY LIGHTS, KEVIN ETC. AS REQUIRED BY LOCAL CODES. A c 5. ALL EMERGENCY AND EXIT LIGHTS HEADER ( P.) CLOSET L BE BUILDING RYW LL APPROVED BY OWNER. ANDARDS AND CEILING @ (N ) CEILING @ HE ER ( P.) 8'-0"AFF 10-6"AFF 6. EVERY FOURTH LIGHT IN THE CORRIDOR /0 IS TO BE A NIGHT LIGHT PER CODE. STUD O 106 7. ELECT. TO VERIFY ALL LOCATIONS OF SCONCES AFTER BOXES HAVE BEEN STUDI 121STU 10120 INSTALLED BUT BEFORE THE WIRING HAS BEEN PULLED IN CASE CHANGES r' ARE WANTED. H M CEILING @' 10'-6"AFF N (NL) WcoM CEILING PLAN LEGEND J R LL _ a J STUDIO 113 VERIFY ALL SELECTIONS WITH STORE OWNER = 0 � Ja N SYMBOLDESCR V 5 W c IPTION STUD O 105 ZZ m V J V H STUD 122 STUDI 119 0,000, OA RECESSED CAN LIGHT-HALO H991CT OR SIMILAR H' F. Z OV z 0,100, 0C a Z J N STUDIE04] H a 2'X 4' FLUORESCENT-LITHONIA GT8 GENERAL PURPOSE TROFFER- a co PRISM LENS-2 LAMPS-5000K FLUORESCENT LAMPS N r CEILING Cu 10'-6"AFib ollSTUD O 114 C WALL SCONCE-66"AFF-PROVIDE LEVITON 9860-LHG LAMPHOLDER W/13W GU24 BASE LAMP (KEYLESS BI-PIN COMPACT FLUORESCENT LAMPHOLDER). KAP DESIGN TO PROVIDE SCONCE DECORATIVE COVER .I I THROUGH SOLA CORPORATE OFFICE: 303-377-7652 STUDID 123 STUDI0 118 (NL) 2'X 2' FLUORESCENT-- LITHONIA PARAMAX PARABOLIC TROFFER 2PM3N-WITH 6"WIDE U LAMP 9 CELL PARABOLIC LENS OR SIMILAR (NL)= NIGHT LIGHT (N L) E IT EXIT LIGHT AS REQUIRED BY CODE STUD O 115 F EXHAUSTFAN DRYWALL . E0:3] HEADER ( P.) 11-81HE DER ) CEILING SPEAKERS INSTALLED BY G.C. �1' CLOSET 2" (NL) CEILIN ]FF OR LAUNDRY ROOM, CHECK WI H-7111 (TO BE TIED TO RADIO INEOWN NT R REGARD- 10'-6" j! ING SOUND SYSTEM.) DRLL HEADER x TII�n1i _ O DRUM LIGHT(TO BE DETERMINED) STUDIO 116 STUDIO 102] _0 00, 0 STUDIO 117 HAYNES CHIDSEY STUDIO 101 lo CEILING @ CEILING @ OWNER ool lo ol 10'-6"AFF 9'-6"AFF BUS.: 704.900.7730 lo (TYP.> CEL.: 303.881 .7314 -----------0 C-2 CEILING W/ DRUM LIGHT VERIFY HEIGHT W/ OWNER PROJECT: SL-FL-253 REFLECTED CEILING PLAN ATLANTIC VILLAGE SCALE: 1/4"=1'-0" RELEASE DATE 04/02/14 REVISIONS: 1 BLDG. DEPT. REVIEW-5/23/2014 DRAWING NAME REFLECTED CEILING PLAN & NOTES REFLECTED CEILING PLAN&NOTES N SHEET NO. Al . 6 } i I SLAT WALL OR CORNER UNIT PLUMBING NOTES 1. ALL PLUMBING WORK TO BE DONE BY A LICENSED WALL 72" 77%If WALL SLIP NUT SUP NUT PLUMBING CONTRACTOR AND TO MEET ALL CABINET CABINET FEDERAL, STATE & LOCAL CODES. 1 SLIP NUT 1 MODEL NO. 40A-5KW 1/ 12" W OPENING AT R F MIRROR MIRROR 12" W OPENING AT REAR OF SLIP NUT ADAPTER ADAPTER 4 1 2. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY V CORNER CABINET FOR MIRRORS CORNER CABINET FOR WASHER WASHER A9� PERMITS AND SHALL PAY ALL REQUIRED F Z PLUMB. FROM WALL- PLUMB./ PLUMB. FROM WALL- ® ` PPROX, Q EES FOR 24 " 54" THIS WORK. PLUMBING MUST BE WITHIN / AT WINDOWS / PLUMBING (APPROX.) C� CORNER CORNER U NG MUST BE WITHIN LAUNDRY Z THOSE DIM. DIM.'S ARE _ 25Z" W INSIDE SINK SINK THOSE DIM. DIM.'S ARE CLEAN-OUT CAP -d X 25X"W OUTSIDE 18" SINK 3. THE CONTRACTOR SHALL FIELD VERIFY EXISTING CRITICAL FOR INSTALLING CRITICAL FOR INSTALLING TRAP i0a _ CONDITIONS AND REPORT TO SYMPATECO, INC., IN J CABINETRY. 4�� I I o = - CABINETRY. CLEAN-OUT ! a - - WRITING, ANY DISCREPANCIES IMMEDIATELY UPON DISCOVERY. HOLD PLUMBING AS w y T= J), I I I I I 1 1i - 4„ HOLD PLUMBING AS CAP STRAINER AND HANDLE a W Z N 1 58L 4. KEEP VENT HEIGHT WITHIN SPECIFIED C Z _ " 17 18 oR 19 OR 20 - - 6„ _ Z DIMENSIONS. CLOSE AS POSSIBLE �r - Z 6 - Z �� CLOSE AS POSSIBLE SI O PROVIDE REFLEX PLASTIC HAIR TRAP. SE,� V TO CORNER 04 00 �° �D� DRAIN �� CVa TO CORNER *** N SYMPATECO SPECIFICATION & INSTALLATION MAN AL 5. KEEP ALL ROUGH PLUMBING WITHIN SPECIFIED 16" - 6" TAILPIECE 6" TAILPIECE `r oo �I�• 16 - 01 FOR URTHER INFORMATION. `'' DIMENSIONS. �N *SEE DRAWING 3/A1.7 FOR HAIR TRAP DETAIL 4 GARFEILD BACKWASH SHAMPOO UNIT 5 58L LAUNDRY SINK 6. KEEP ALL VERTICAL VENT PIPES WITHIN A1.7 SCALE:3/8" = 1' 0" A1.7 SCALE: 3/8" = 1' o" DISPENSARY, UTILITY, LAVATORY AREAS & NOT IN 1 3B CORNER UNIT - RIGHT 2 3B CORNER UNIT - LEFT 3 HAIRTRAP A1.7 SCALE:3/8" = 1' o" A1.7 SCALE: 3/8" = 1'-0" A1.7 N.T.S. i FINISHED SHAMPOO AREA. IF VENT RUNS OUTSIDE CERTIFIPR /BY: WALLS, GENERAL CONTRACTOR MUST BOX IN. \� `�`\\1 D H94 , L\CENS'�.' WASHER HOOK UP- SEE 7. NECESSARY VACUUM BREAKERS ARE PROVIDED BY ,�Q:' •,p� INSTALLATION MANUAL j SYMPATECO, INC. TO BE INSTALLED BY PLUMBER, = No. 60531 PLUMBING WITHIN AT TIME OF SINK HOOK UP. = �. CABINETRY- NO BACKS ON •. ' zzzzl "z' CABINET FOR PLUMBING ACCESS 8. SYMPATECO, INC. SUPPLIES SINK WITH 4" TAIL ®,�•.. STATE OF lV�\ °0000 WALL - 6-8 1/ ° ZORIVIN PIECE, SHAMPOO HOSE & SPRAY, HAIR STRAINERS, �i, 10 411 _ N O �:q) rte_ ` _ c? °' HAIR TRAP & FAUCET FIXTURES. PLUMBER TO ��,���AL\\��\ A117 ®FD N �1 EQUIP. MECH. WATER SUPPLY CHROME "SWING" TYPE "P" TRAP, CHROME 1 11,12 CSI 12 q 1 - 10 r r f m Al 7 A117qcl) All L� W/pl a 'n n A,7 L L HEATERS/TANKS 22U SHUTOFF CHROME FLEXIBLE WATER FEEDS & ALL -- 5 pp� 4 r r SEE NOTE #18 0 0 10 FITTINGS. ® O ENS I N ® A1.7 I� All ALL PLUMBING LINES �1 In BOTTLE WELL N FD �1'-6' q i FD i bL__�N � � I �� ,� " ;, 12" 22s & VENTS TO REMAIN 9. EXTEND ALL ROUGH PLUMBING FROM WALL. -AS L___W/D y `= y �= SHAMPOO WITHIN WALLS NOTED- LJ L----J SHAMPOO 33" SINK ES SINK WOMENS STUDIO 109 i I 0 STUB PLUMBING , II 10. PLUMBING CONTRACTOR TO VERIFY ALL FIELD DRAWN BY: MEASUREMENTS. I �N I I OUT 6" FROM WALL " -cv KEVIN SEE MFA. BREAK RM. r j STUDIO 108 2 M' 11 II �l c� FOR r l i A1.7 `'' 226 - z =J ccyi 11 . PLUMBER TO PROVIDE ALL ROUGH-IN PLUMBING I ' I I Na PRIOR TO INSTALLATION OF SHAMPOO CABINETS & PLUMB. i ; I I FLOOR DETAILS i i i A1.7 -- 45" -mak 4 RETURN AFTER CASEWORK INSTALLATION TO 11 1211HOOK UP/ INSTALL SINKS AS NEEDED. DRAIN C) ilil 3 *SEE DRAWING 3/A1.7 FOR HAIR TRAP DETAIL 24 12. PLUMBING CONTRACTOR TO VERIFY PLUMBING O 1 SUPPLY LINES ° ° 6 22 SHAMPOO UNIT REQUIREMENTS FOR ALL FIXTURES & EQUIPMENT A1.7PROVIDED BY OWNER & SYMPATECO, INC. ® rr j I j SCALE:3/8" = V-0" A1.7 r 1 f 9,z 7,1 3�E 13. WALL THICKNESS MAY VARY FROM PLAN AS SHOWN DEPENDING ON LOCAL REQUIREMENTS E T A1.7 WALL AND EXISTING CONDITIONS. II r STUDIO 110 1 jui STUDIO 111 1 r eAll 14. PLUMBER TO PROVIDE PLUMBING SUPPLY LINESTUDIO 107 SHUT-OFF PER PLUMBING RUN. PLUMBER TO w CO M (e 1,7,2 STUDIO 112 BAR SINK Ij SHOW OWNER WHERE SHUT OFF VALVES ARE AND t� p J SHOW HOW VALVES OPERATE. J Q w A1.7 J 60 ALL PLUMBING LINES 54" 42" n J > _ 42° 0 0JQ 30" I-'- & VENTS TO REMAIN 27" � 12„� � � 15. ALL SINKS FOR EMPLOYEES OR PUBLIC USE SHALL _ = w 1 , WITHIN WALLS 12' BAR SINK BE A MAXIMUM OF 6-%" DEEP AND MOUNTED WITH A Z O m i , ------ BAR S NK BAR SINK THE TOP EDGE A MAXIMUM 34" A.F.F. SINK DEPTH Q m v ------ ----- N -V_ 2 � C° ,_ STUDIO 106 - ' DOES NOT APPLY TO LAVATORIES. �' v IL ~ A1.7 ..o I I - ll� - N 0 _ _ G� a Z J CLOSET 1 10 84 92 1 oo O Z 31101 15L1 138E sRl 15R 16. ALL FLUSH VALVE HANDLES FOR THE WATER © Q � 1 1 - I r a CV o - _ - - r 0 CLOSETS SHALL FACE THE OPEN SIDE OF THE FLOOR N u - - ROOM. G.C. TO PROVIDE POWER FLUSH TOILETS. 04 a I , -- ----- 1 1 17. G.C. TO HAVE WATER TESTED TO DETERMINE IF ;I it WATER SOFTENER IS NEEDED. 1 I I 7 10/84/92 COLDR BAR 8 310 COLOR BAR 9 15L/38L COLOR BAR 10 15R/38R COLOR BAR 18. G.C. TO PROVIDE GAS WATER HEATERS IF _ A1.7 I STUDIO 121 2 I STUDIO 120 1 1 1.7 i A1.7 l ; SCALE: 3/8" - 1' A1.7 SCALE: 3/8" = 1'-0" A1.7 SCALE:3/8" = 1'-0" A1.7 SCALE: 3/8" ='1'-0" AVAILABLE. LOCKINVAR. VERIFY SELECTION W/ oloo A1.7 r l A1.7 1 1 r l z OWNER. STUDIO 113 I A1.7 2 I t A1.7 All rl 1 RESTROOM FIXTURES STUDIO 105 A1•7 (VERIFY W/ OWNER) KOHLER LAV. SINK STUDIO 114 � STUDIO 119 '�� INSTALL SINK UONDERM ROUNDSELF-RIMMING/UNDERCNTR l STUDIO 122 2 r OUNT ONLY A1.7 MODEL NO.: K-2610-SU , 1 1 11 z r 1 GIAGNI LAV. FAUCET 11 1 1 I 1 A1.7 A1.7 2 r j STUDIO 2 I I I , A1.7 r ; A1.7 „ , STYLE: GIAGNI SINGLE HANDLE POLISHED CHROME X t , MODEL NO.: LL102-PC 11 A1.7 s� MIRROR Inti PROVIDED BY OWNER - INSTALLED BY G.C. x :va><os CO 12" W. OPENING Al REAROF SOLID SURFACE COUNTERTOP 1 1 CORNER CABINET FORT RAIN & 2211 \ A1.7 1 r ► 2 , I I SUPPLY PLUMB. FROM I 15" L2 - SOLID SURFACE COUNTERTOP A1.7 A1.7 1 r WALL--PLUMBING MUS BE ' 1 I 1 r Z ��"- 12" TILES WAINSCOAT SET A 450 ANGLE ON ALL WALLS, WITHIN THOSE DIMENSh NS. - o - @ STUDIO 115 ► ' ' 1 A1.7 DIMENSIONS ARE CRITICAL FOR d�'Z Z Z Zit 48" A.F.F. RESTROOM TILE FOR PREMIUM RESTROOMS STUDIO 123 A17 STUDIO 118 i i INSTALLING 6" MAX. 8" MIN. W o Q VERIFY FINISH WITH OWNER. i ALLING CABINETR (TYP.). lt � _ _ HAYNES CHIDSEY STUDIO 103 SEE DETAILS 1 AND 2/A .7 17 M N MIN N 16" 335 " -- - « ca'�I U 1 I OWNER BUS.: 704.900.7730 III I� __ �+ CEL.: 303.881 .7314 3'-9" i i A8.7 °' 11 WASHBASIN PLUMBING DETAILS 04 6„ f A1.7 SCALE: 3/8 - 1 -0 \Ll'-5 1/2" 69 A1.7 1 - ----- -J--- ------ ----- ----_oma►----- -------- ------- --------- ;I NOTE: GC TO COORDINATE LOCATION OF GRAB BAR W/ LAVATORY SPECIFIED, TO ENSURE REQUIRED AREA TO rm to I ° -2 INSTALL GRAB BAR AT TOILET TYP. PROJECT: I STUDIO 101 *PROVIDE BACKING AS REQUIRED SL-FL-253 STUDIO 117 I a N ATLANTIC VILLAGE STUDIO 116 I A1.7 L 6" MAX. ° 4 -' n n 39" MIN- RELEASE DATE 41" MAX. s,10 STUDIO 102 _J� 36" MIN. 04/02/14 z A1.7 12" MAX. 12" A1.7 -1 00 ? MIN REVISIONS: LIDN 42" MIN. r 24° 1 BLDG. DEPT. REVIEW-5/23/2014 MIN. 18 lf CI • J - � �` � ZC0 Md r- G c 0 PLUMBING LAYOUT DISPENSERS SHALL NOT BE OF TYPE THAT CONTROL rt SCALE: 1/4"=1'-0" 7" MIN.- 9" MAX. DRAWING NAME DELIVERY OR DOES NOT ALLOW CONTINUOUS FLOW. PLEASE PROVIDE 2 ROLL DISPENSERS. PLUMBING LAYOUT & DETAILS PLUMBING LAYOUT& DETAILS SHEET NO. 12 TOILET/ URINAL PLUMBING DETAILS A1.7 SCALE: 3/8" = 1'-0" A1 . 7 'r i i I ELECTRICAL EQUIPMENT SPECIFICATIONS PANELS: SQUARE D TYPE NQODCU RECESSED MOUNTED COPPE BUS, BOLTED CIRCUIT PANEL NEW "A" LUGS 200 AMP PANEL NEW "C" LUGS 100 AMP BREAKER PANELBOARD, 120/208 VOLT, 3PH., 4 WIRE OR EQUIVALENT. TIME CLOCK: COORDINATE NH ELECTRICAL CONTRACTOR 120/208 VOLT 3 PHASE 4 WIRE MAIN BREAKER M-L-O 120/208 VOLT 3 PHASE 4 WIREMAIN BREAKER M-L-O DUPLEX RECEPTACLES: HUBBELL #5262-WHI. UNLESS OTHERWISE NOTED. DUPLEX RECEPTACLES: HUBBELL #5262-BL. UNLESS OTHERWISE NOTED. WIRE CKT. LOAD BKR BKR LOAD CKT. WIRE WIRE CKT. LOAD BKR BKR LOAD CKT. WIRE • QUAD RECEPTACLE: TWO (2) HUBBELL #5262-WHI DUPLEX RECEPTACLES IN COMMON SIZE USE NO. KVA SIZE A B C SIZE KVA NO. USE SIZE SIZE USE NO. KVA SIZE A B C SIZE KVA NO. USE SIZE JUNCTION BOX NH 4 GANG COVER PLATE UNLESS OTHERWISE NOTED. 1 3170 40/3 40/3 3710 2 12 20 20 ISOLATED GROUND RECEPTACLES: HUBBELL #G-5262-WHI UNLESS OTHERWISE NOTED. # RECPT STUDIO 101 FLEX 1 500 /1 /1 500 2 RECPT STUDIO 112 FLEX #12 _ ISOLATED GROUND QUAD RECEPTACLES: TWO (2) HUBBELL MG-5262-WHI DUPLEX 8 NEW A.C. UNIT 1 3 3170 3710 4 W A.C. UNIT 3 #8 RECEPTACLES IN COMMON JUNCTION BOX WITH 4 GANG COVER PLATE UNLESS # # # #12 RECPT STUDIO 102 FLEX 3 500 500 4 RECPT STUDIO 112 FLEX #12 OTHERWISE NOTED. 5 13170 3710 6 #12 RECPT STUDIO 102 FLEX 5 500 500 6 RECPT STUDIO 113 FLEX #12 GROUND FAULT RECEPTACLE: HUBBELL #GF-5252-WA UNLESS OTHERWISE NOTED. 7 3710 T40/3 40/3 3170 8SINGLE POLE SWITCHES: HUBBELL #HBL-1221-WHI. #12 RECPT STUDIO 103 FLEX 7 500 500 8 RECPT STUDIO 114 FLEX #12Pl #8 NEW A.C. UNIT #2 9 3710 3170 10 W A.C. UNIT #4 #8 #12 RECPT STUDIO 104 FLEX 9 500 500 10 RECPT STUDIO 115 FLEX #12 11 3710 3170 12 #12 RECPT STUDIO 105 FLEX 11 1 500 500 12 RECPT STUDIO 116 FLEX #12 (f� ELECTRICAL NOTES #12 WP/GFI RECEPTACLES 13 720 20/1 20/1 14 SIS RE #12 RECPT STUDIO 106 FLEX 13 500 500 14 RECPT STUDIO 116 FLEX #12 6d #12 GENERAL RECPT 15 360 16 SR RE 12 RECPT STUDIO 107 15 REMOVE ALL EXISTING LIGHTING FIXTURES, SWITCHES, JUNCTION BOXES, CONDUIT, # FLEX 500 500 16 RECPT STUDIO 117 FLEX #12 5q,I WIRING, ETC., NOT REQUIRED FOR REUSE. #12 MICROWAVE 17 800 18 SFS RE #12 RECPT STUDIO 108 FLEX 17 500 500 18 RECPT STUDIO 118 FLEX #12 U� REUSE THE TWO 120/208 VOLT, 200 AMP ELECTRICAL SERVICES CURRENTLY FEEDING THE #12 REFRIGERATOR 19 1200 20 SFS RE #12 RECPT STUDIO 109 FLEX 19 1 500 500 20 RECPT STUDIO 119 FLEX #12 SPACE. CONFIRM SIZE AND VOLTAGE CHARACTERISTICS OF EXISTING SERVICES AT SITE. BASE BID SHALL INCLUDE ANY ADDITIONAL CONDUIT AND WIRING AND CONNECTIONS OF #12 WASHER/DRYER 121 11000 22 SIS RE #12 RECPT STUDIO 110 FLEX 21 500 500 22 RECPT STUDIO 120 FLEX #12 THE ELECTRICAL EQUIPMENT, ETC. #12 WASHER/DRYER 23 1000 24 SPS RE #12 RECPT STUDIO 111 FLEX 23 500 REUSE THE EXISTING SERVICE DISTRIBUTION EQUIPMENT INCLUDING THE TWO METERS AND 200 500 24 RECPT STUDIO 121 FLEX 12 AMP DISCONNECT SWITCHES. VERIFY AND CHANGE AS REQUIRED TO ADEQUATELY PROTECT THE #12 LAUNDRY GENERAL RECPT 25 540 26 SP RE #12 SPARE 25 500 500 26 RECPT STUDIO 122 FLEX #12 FEEDER TO THE SPACE. IF ANY ISSUES ARISE WITH REGARD TO REUSE OF SERVICE AND #12 LAUNDRY TV 27 360 28 SP RE #12 SPARE 27 500 28 RECPT STUDIO 123 FLEX #12 CERTIFIED BY: EQUIPMENT, CONTACT ARCHITECT AND/OR ENGINEER PRIOR TO BID FOR DISPOSITION. THE ELECTRICAL CONTRACTOR SHALL FIELD VERIFY AND VIEW ALL EXISTING CONDITIONS #12 MECHANICAL ROOM 129 1080 30 1 SP! RE #12 SPARE 29 30 SPARE #12 \`\`\IIIIIIrrr/// NOTBEFORE BE PERMITTED FOR FAILUREL FOR THE WORK AS TO MAKE THIS VISIT.DESCRIBED AND SHOWN. EXTRAS WILL #12 TOILET GFI RECPT 31 360 360 32 W TER HEATERS #12 #12 SPARE 31 32 SPARE 12 \�' �W D H®�� ����� #12 DRINKING FOUNTAIN 33 180 30/2 2250 34 D YER #10 # �,�ceNSE'••'�0 % #12 SPARE 33 34 SPARE 12 �' ' O THE INTENT OF THE WORK WITH REGARD TO ELECTRICAL DISTRIBUTION AS INDICATED ON # THE DRAWINGS IS AS FOLLOWS: - SPARE 35 2250 36 #12 SPARE 35 36 SPARE #12 No.60531 A. ALL EXISTING ELECTRICAL EQUIPMENT NOT CURRENTLY BEING USED TO FEED 30 2250 ANYTHING AND NOT REQUIRED AS PART OF THIS REMODEL SHALL BE REMOVED. - SPARE 37 /2 38 D YER #10 #12 SPARE 37 38 SPARE - #12 - -�B. EXISTING ELECTRICAL EQUIPMENT CURRENTLY BEING USED TO FEED LIGHTING, SPARE 39 40 SPARE EQUIPMENT, ETC, SHALL BE REUSED. A DETAILED FIELD INSPECTION OF THE SPARE 39 2250 40 #12 #12 0 •...• STATE OF .• ..��L(/�� EXISTING EQUIPMENT SHALL BE INCLUDED IN THE BASE BID TO DETERMINE ITS - SPARE 41 20/1 42 S RE #12 SPARE 41 42 SPARE 12 i��s ..<ORION CONDITION AND COSTS TO PERFORM MAINTENANCE SERVICE. INSPECTION SHALL * BALANCE 20.00% �� �s�rriiii►����` INCLUDE THE FOLLOWING: "*" INDICATES PANEL LOCKS PHASE A: 19190 WATTS BALANCE 6.30% " INDICATES PANEL LOCKS PHASE A: 5000 WATTS ' ONA. 1. CHECK ENTIRE INSTALLATION FOR CODE COMPLIANT CLEARANCES. MODIFY INSTALLATION AND EQUIPMENT LOCATION AS REQUIRED. PHASE B: 20160 WATTS C NECTED DEMAND PHASE B: 4500 WATTS PHASE C: 18890 WATTS CONNECTED DEMAND 2. CHECK CONDUITS FOR PROPER INSTALLATION, I.E. TIGHT 1 9,275 W. 106,622 W. PHASE C: 4000 WATTS CONNECTIONS, PROPER FITTINGS, RUSTING, CREASING, BENDING, 13,000 W. 11,500 W. ETC. REPAIR OR REPLACE AS REQUIRED. TOTAL 58240 WATTS 4P3.54 A. 296.17 A. TOTAL 13500 WATTS 36.11 A. 31.9 A. , 3. CHECK FOR BARE WIRING. COVER OR REPLACE AS REQUIRED. 4. CHECK FOR PROPER GROUNDING OF SYSTEM AND EQUIPMENT. CORRECT AS REQUIRED. 5. CHECK FOR CIRCUIT OVERLOADING AND/OR TRIPPING. REPLACE BREAKERS AND/OR FUSES AS REQUIRED. REDISTRIBUTE CIRCUITING OF EQUIPMENT AND/OR LIGHTING AS REQUIRED. 6. REPAIR ANY RUSTED AREAS ON EQUIPMENT CASINGS. REPAINT AS PANEL NEW "B" 200 AMP DRAWN BY: REQUIRED. LU GS 7. VERIFY THE SIZES OF THE EQUIPMENT IN FIELD AS SHOWN AND CALLED FOR - IF EQUIPMENT IS NOT SIZED AS REQUIRED, CONTACT 120 208 VOLT 3 PHASE 4 WIRE MAIN BRE KER M-L-o KEVIN THE ARCHITECT/ENGINEER. WIRE CKT. LOAD BKR BKR LOAD CKT. WIRE AN ALTERNATE PROPOSAL SHALL BE SUBMITTED TO REPLACE ANY AND/OR ALL EXISTING SIZE USE NO. KVA SIZE A B C SIZE KVA N0. USE SIZE EQUIPMENT, IF THE EQUIPMENT IS DETERMINED TO BE IN NEED OF REPLACEMENT AFTER #12 LTG. STUDIO 1 1088 20/1 20/1 200 2 LT . WALL SCONCES #12 THE INSPECTION AT THE JOB SITE. ALTERNATE PROPOSAL SHALL BE COMPLETE. #12 LTG. STUDIO 3 1216 840 4 LT . HALLWAY #12 FURNISH AND INSTALL NEW ELECTRICAL EQUIPMENT INCLUDING ELECTRICAL PANELS "A", #12 LTG. STUDIO 5 704 704 6 LT, . HALLWAY #12 NEW DISC SW #1 NEW DISC SW #3 "B" AND "C" AS SHOWN AND CALLED FOR. 60/40, NEMA 3R 60/40, NEMA 3R #12 LTG. STUDIO 7 768 325 8 NI T/EM LIGHTS #12 FURNISH AND INSTALL TYPEWRITTEN PANEL DIRECTORIES AS SHOWN. #12 SPARE 9 1200 10 SI . AGE #12 * CIRCUITS SHALL BE CONNECTED TO THE PANELS AND ARRANGED TO COMPLY WITH THE NEW AC UNIT #1 -� NUMBERS SHOWN ON THE DRAWINGS. UNUSED CIRCUITS SHALL BE UTILIZED AS SPARES. #12 BREAK ROOM Ill 1 192 900 112 RE PT T.V. #12 ON ROOF NEW ROOFTOP #12 RESTROOM/MECH 13 884 FURNISH AND INSTALL NEW TIME CLOCK. 900 14 R PT STUDIO 114 #12UNIT #3 PROVIDE ADEQUATE TEMPORARY POWER AND LIGHTING. #12 RECPT STUDIO 101 15 1260 900 16 RE PT STUDIO 115 #12 #12 RECPT STUDIO 102 17 1440 900 18 RFl PT STUDIO 116 #12 3-#8, 1#6 GRD. 1/2"C. ---� �-- 3_ THE MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL FOUR (4) ROOFTOP AIR #8, 1#6 GRD. 1/2 C. CONDITIONING UNITS. THE ELECTRICAL CONTRACTOR SHALL CONNECT THE NEW ROOFTOP #12 RECPT STUDIO 103 119 1620 1 1 900 20 Rd PT STUDIO 116 #12 w UNITS AFTER THEY HAVE BEEN SET IN PLACE. VERIFY TOTAL LENGTH OF CONDUIT AND # #12 NEW DISC SW #2 NEW DISC SW #4 �= M WIRING REQUIRED IN FIELD PRIOR TO BID. 12 RECPT STUDIO 104 21 900 1080 22 RE, PT STUDIO 117 60/40, NEMA 3R 60/40, NEMA 3R N TIME CLOCK AND OTHER MISCELLANEOUS ELECTRICAL COMPONENTS SHALL NOT BE INSTALLED #12 RECPT STUD10105 23 900 1080 24 RE PT STUDIO 118 #12 W r� O � J ON THE TELEPHONE TERMINAL BOARD. #12 RECPT STUDIO 106 25 900 900 26 RL PT STUDIO 119 #12 Q p: u. NEW AC UNIT #2-+- Q MAINTAIN ALL REQUIRED CLEARANCES AT ALL ELECTRICAL EQUIPMENT AND COMPLY WITH #12 RECPT STUDIO 107 27 900 1080 28 RE PT STUDIO 120 #12 ON ROOF NEW ROOFTOP N.E.C. ARTICLE 110. #12 RECPT STUDIO 108 29 1 9001080 30 Rbk PT STUDIO 121 #12 A.C. UNIT #4 �o V J Q FURNISH AND INSTALL NEW FIRE ALARM SYSTEM (IF REQUIRED). COORDINATE WITH #12 RECPT STUDIO 109 31 1080 900 32 RECPT STUDIO 122 #12 H- 0 in LANDLORD. #12 RECPT STUDIO 110 33 1620 1080 34 RE PT STUDIO 123 #12 Q m U 3-#8, 1#6 GRD. 1/2"C. �' U z TEMPERATURE CONTROL EXCLUDED FROM ELECTRICAL CONTRACT. �= #12 RECPT STUDIO 111 35 1260 36 SP, RE #12 i- � CONTRACTOR SHALL NOTIFY THE ARCHITECT AND/OR ENGINEER OF ERRORS, OMISSIONS OR 100 3-#8, 1#6 GRD. 1/2"C. Q Z ORK, OR, FAILING #12 RECPT STUDIO 112 37 1080 /3 5000 38 Q SUCH DISCREPANCIES SHALL RBECRESPONS BOLE FOR CORRECTING R FABRICATION OSAME FWITHOUECTED T/ COST TO TENANT, #12 RECPT STUDIO 112 39 1080 4500 40 P NEL C FEED F- ARCHITECT OR ENGINEER. Q - � WORK SHALL INCLUDE START UP OF ALL SYSTEMS. PROVIDE ONE YEAR LABOR WARRANTY ON RECPT STUDIO 113 41 1080 4000 42 NC ENTIRE INSTALLATION AND ONE YEAR PARTS WARRANTY ON ALL EQUIPMENT SUPPLIED BY "*" INDICATES PANEL LOCKS PHASE A: 16545 WATTS BALANCE 14.25% r- SUB-CONTRACTOR. FURNISH ALL MANUALS, MAINTENANCE INSTRUCTIONS, AND WARRANTIES PHASE B: 17656 WATTS TO CONTRACTOR. CO 4NECTED DEMAND MOUNT SWITCHES 4'-0" ABOVE FLOOR UNLESS OTHERWISE NOTED. PHASE C: 15140 WATTS 4C,955 W. 31,218 W.TOTAL 49341 WATTS 1 3.76 A. 86.7 A. ALL CONDUITS FOR USE BY OTHERS SHALL BE CONTINUOUS, CONTAIN PULL STRINGS, AND HAVE PULL BOXES AS NECESSARY. EXTERIOR OF BUILDING SOLA SPACE NOTE: NOTE: EXISTING TO REMAIN ALL RECEPTACLE LOADS ARE BASED ON EMERGENCY/EXIT/NL LIGHTING SHALL 4-#250 KCMIL, 1 #1/0 AL GRD., 2 1/2"C, III 180 WATTS FOR DUPLEX DEVICES AND BE ON SEPERATE CI CUIT WITH BATTERY 360 WATTS FOR QUAD DEVICES. BACK-UP. J 4-#250 MCM AL, 1#1/0 GRD., 2-1/2"C. J EXISTING 200 EXISTING 200 GRD., 1-1 AL 1 , 1 4 NOTE: AMP DISC SW. AMP DISC SW. 4-# # /2"C. ELECTRICAL SERVICE LOAD SUMMARY ALL PANEL LOCK DEVICES MUST BE U.L. WITH 200 AMP WITH 200 AMP LABELED-LISTED. I FUSES TO REMAIN FUSES TO REMAIN LOAD ACTUAL N.E.C. N.E.C. DESCRIPTION CONNECTED DEMAND DEMAND LOAD FACTOR WATTAGE � TC SIGN 750 125% 938 LIGHTING 7,120 125% 8,900 * ALL ELECTRICAL EQUIPMENT AND MATERIAL O 200A. O 200A. **LIGHTING 4,725 SQ.FT. X 3W/SQ.FT. X 125% 17,719 * SHALL BE SUITABLE FOR INSTALLATION NEW NEW NEW AND USE IN CONFORMITY WITH NEC 110.3(A)(1) 400 AMP 200 AMP 100 AMP RECEPTACLES 50,440 1 ST 1 OKW 0 100% 37,560 120/208V. 120/208V. 120/208V. PNL "A" � PNL B � PNL C REMAINING ® 50% x rvaiop NOTE: 400 AMP M-L-O M-L-O AIR CONDITIONING* 114 A. 208 x 1.732 41,069 SEAL AROUND ALL ELECTRICAL PENETRATIONS OF RUN NEW 200 AMP 120/208V. 3PH., 4W. SERVICE M-L-O HEATING* 0% FULL HEATING LOAD FIRE RATED WALLS PER NEC 300.21. 4-#250 KCMIL, 1 #1/0 AL GRD., 2 1/2"C, BREAKER DRYERS 40.8 A. 220 x 1 8,976 WATER HEATERS 360 100% 360 NOTE: MISCELLANEOUS - 100% - ALL �ECTRICAL WORK MUST COMPLY TOTAL CONNECTED 108,715 TOTAL DEMAND 106,622 WITHFPA 70. NOTES: TOTAL AMPERAGE 296.17 NOTE: HAYNES CHIDSEY * USE GREATER LOAD OF THE TWO CONNECT ALL GROUNDING SYSTEMS, PHONE, OWNER ** SHOW WINDOW LIGHTING CALCULATED PER NEC ARTICLE 220-14(8)(1) TVA D SECURITY. LOW VOLTAGE IS BY BUS.: 704.900.7730 ELECTRICAL CONTRACTOR AND SHALL CONSIST OF ONE CAT-5 AND ONE RG6 TO EACH GROUND CEL.: 303.881 .7314 SALOIN ROOM FOR FUTURE USE. REQUIRED ELECTRICAL SERVICE EX 400A. TOTAL NOTE: ALL GROUNDS IN EXISTING EQUIPMENT SHALL REMAIN WITH NO NEW WORK REQUIRED. RISER DIAGRAM NOTES 1 . OBTAIN AVAILABLE FAULT CURRENT RATING AND PROVIDE NOTE: PROTECTION FOR MAIN CIRCUIT BREAKER AND ALL EXISTING METER AND DISCONNECT SWITCHES BRANCH DEVICES. PROJECT: LOCATEVERIFY DAT L CATIONROF IN FIELD. TO REMAIN. 2. MAINTAIN ALL REQUIRED CLEARANCES PER ARTICLE SL-FL-253 110-26 NEC ATLANTIC VILLAGE 3. COPPER OR ALUMINUM IS ACCEPTABLE FOR SERVICE RUNS. VERIFY IN FIELD. RELEASE DATE 04/02/14 POWER RISER DIAGRAM REVISIONS: 1 BLDG. DEPT. REVIEW-5/23/2014 NOT TO SCALE DRAWING NAME ELECTRICAL SPECIFICATIONS N SHEET NO. E1 . 1 2--- _j ry f ELECTRICAL EQUIPMENT SPECIFICATIONS PANELS: SQUARE D TYPE NQODCU RECESSED MOUNTED COPPE BUS, BOLTED CIRCUIT PANEL NEW "A" LU GS 200 AMP PANEL NEW "C" BREAKER PANELBOARD, 120/208 VOLT, 3PH., 4 WIRE OR EQUIVALENT. LUGS 100 AMP TIME CLOCK: COORDINATE WITH ELECTRICAL CONTRACTOR 120/208 VOLT 3 PHASE WIRE MAIN BRED ER M-L-O 120/208 VOLT 3 PHASE 4 WIREMAIN BREAKER M-L-0 DUPLEX RECEPTACLES: HUBBELL #5262-WHI. UNLESS OTHERWISE NOTED. DUPLEX RECEPTACLES: HUBBELL #5262-BL. UNLESS OTHERWISE NOTED. WIRE KT. LOAD BKR BKR LOAD CKT. WIRE WIRE CKT. LOAD BKR BKR LOAD CKT. WIRE • QUAD RECEPTACLE: TWO (2) HUBBELL #5262-WHI DUPLEX RECEPTACLES IN COMMON SIZE USE 0. KVA SIZE A B C SIZE KVA NO. USE SIZE SIZE USE NO. KVA SIZE A B C SIZE KVA NO. USE SIZE JUNCTION BOX WITH 4 GANG COVER PLATE UNLESS OTHERWISE NOTED. 1 3170 ISOLATED GROUND RECEPTACLES: HUBBELL #G-5262-WHI UNLESS OTHERWISE NOTED. 40/3 40/3 3710 2 #12 RECPT STUDIO 101 FLEX 1 500 20/1 20/1 500 2 RECPT STUDIO 112 FLEX #12 ISOLATED GROUND QUAD RECEPTACLES: TWO (2) HUBBELL #IG-5262-WHI DUPLEX #'8 NEW A.C. UNIT #1 3 3170 3710 4 NE A.C. UNIT 3 8 RECEPTACLES IN COMMON JUNCTION BOX WITH 4 GANG COVER PLATE UNLESS # # #12 RECPT STUDIO 102 FLEX 3 500 1 500 4 1 RECPT STUDIO 112 FLEX #12 OTHERWISE NOTED. 5 3170 3710 6 #12 RECPT STUDIO 102 FLEX 5 500 500 6 RECPT STUDIO 113 FLEX #12 GROUND FAULT RECEPTACLE: HUBBELL #GF-5252-WA UNLESS OTHERWISE NOTED. #12 RECPT STUDIO 103 FLEX 7 500 500 8 RECPT STUDIO 114 F SINGLE POLE SWITCHES: HUBBELL #HBL-1221-WHI. 7 3710 40/3 40/3 3170 8 LEX #12 #8 NEW A.C. UNIT #2 9 3710 3170 10 NE A.C. UNIT #4 #8 #12 RECPT STUDIO 104 FLEX 9 500 500 10 RECPT STUDIO 115 FLEX #12 -J 11 3710 3170 12 #12 RECPT STUDIO 105 FLEX 11 500 500 12 RECPT STUDIO 116 FLEX #12 Z ELECTRICAL NOTES #12 WP/GFI RECEPTACLES 13 720 20/1 20/1 14 SPA,i E #12 RECPT STUDIO 106 FLEX 13 500 500 14 RECPT STUDIO 116 FLEX #12ui #12 GENERAL RECPT 15 360 16 SPA E #12 RECPT STUDIO 107 FLEX 15 500 500 16 t REMOVE ALL EXISTING LIGHTING FIXTURES, SWITCHES, JUNCTION BOXES, CONDUIT, RECPT STUDIO 117 FLEX #12 WIRING, ETC., NOT REQUIRED FOR REUSE. #12 MICROWAVE 17 800 18 SPA,! E #12 RECPT STUDIO 108 FLEX 17 500 500 18 RECPT STUDIO 118 FLEX #12 U� REUSE THE TWO 120/208 VOLT, 200 AMP ELECTRICAL SERVICES CURRENTLY FEEDING THE #12 REFRIGERATOR 19 1200 20 SPAFIE 12 RECPT STUDIO 109 FLEX 19 500 SPACE. CONFIRM SIZE AND VOLTAGE CHARACTERISTICS OF EXISTING SERVICES AT SITE. # 500 120 RECPT STUDIO 119 FLEX #12 BASE BID SHALL INCLUDE ANY ADDITIONAL CONDUIT AND WIRING AND CONNECTIONS OF #12 WASHER/DRYER 21 1000 22 SPA E #12 RECPT STUDIO 110 FLEX 21 500 500 22 RECPT STUDIO 120 FLEX #12 THE ELECTRICAL EQUIPMENT, ETC. #12 WASHER/DRYER 23 1000 24 SPA E 12 RECPT STUDIO 111 FLEX 23 500 # 500 24 RECPT STUDIO 121 FLEX #12 REUSE THE EXISTING SERVICE DISTRIBUTION EQUIPMENT INCLUDING THE TWO METERS AND 200 #12 LAUNDRY GENERAL RECPT 25 540 26 SPA E AMP DISCONNECT SWITCHES. VERIFY AND CHANGE AS REQUIRED TO ADEQUATELY PROTECT THE ,! #12 SPARE 25 500 500 26 RECPT STUDIO 122 FLEX #12 FEEDER TO THE SPACE. IF ANY ISSUES ARISE WITH REGARD TO REUSE OF SERVICE AND #12 LAUNDRY TV 27 360 28 SPAT E #12 SPARE 27 500 28 RECPT STUDIO 123 FLEX #12 CERTI �� iG�,� : EQUIPMENT, CONTACT ARCHITECT AND/OR ENGINEER PRIOR TO BID FOR DISPOSITION. y THE ELECTRICAL CONTRACTOR SHALL FIELD VERIFY AND VIEW ALL EXISTING CONDITIONS #12 MECHANICAL ROOM 29 1080 30 SPARE #12 SPARE 29 30 SPARE #12 ��`�\W p. H0 ���%� BEFORE SUBMITTING A PROPOSAL FOR THE WORK AS DESCRIBED AND SHOWN. EXTRAS WILL #12 TOILET GFI RECPT 31 360 360 32 WAT R HEATERS LB NOT BE PERMITTED FOR FAILURE TO MAKE THIS VISIT. #12 #12 SPARE 31 32 SPARE #12 \ ��,• '\,\CENsF' .!A0 #12 DRINKING FOUNTAIN 33 180 30/2 2250 34 DR. R 10 34 SPARE #12 THE INTENT OF THE WORK WITH REGARD TO ELECTRICAL DISTRIBUTION AS INDICATED ON # #12 SPARE 33 No.60531 THE DRAWINGS IS AS FOLLOWS: - SPARE 35 2250 36 #12 SPARE 35 36 SPARE #12 ��' ' � � �k A. ALL EXISTING ELECTRICAL EQUIPMENT NOT CURRENTLY BEING USED TO FEED ANYTHING AND NOT REQUIRED AS PART OF THIS REMODEL SHALL BE REMOVED. SPARE 37 30/2 2250 38 DR R - #10 #12 SPARE 37 38 SPARE #12 '• w B. EXISTING ELECTRICAL EQUIPMENT CURRENTLY BEING USED TO FEED LIGHTING SPARE 39 2250 40 #12 ® STATE OF EQUIPMENT, ETC, SHALL BE REUSED. A DETAILED FIELD INSPECTION OF THE #12 SPARE 39 40 SPARE . ' EXISTING EQUIPMENT SHALL BE INCLUDED IN THE BASE BID TO DETERMINE ITS - T2 /. FCOR...SPARE 41 42 SPA E ,�` CONDITION AND COSTS TO PERFORM MAINTENANCE SERVICE. INSPECTION SHALL #12 SPARE 41 42 SPARE #12 `SS/ INCLUDE THE FOLLOWING: "*" INDICATES PANEL LOCKS PHASE A: 19190 WATTS BALANCE 6.30% "*" ��,,0NAi. 1. CHECK ENTIRE INSTALLATION FOR CODE COMPLIANT CLEARANCES. INDICATES PANEL LOCKS PHASE A: 5000 WATTS BALANCE 20.00% MODIFY INSTALLATION AND EQUIPMENT LOCATION AS REQUIRED. PHASE B: 20160 WATTS CONtIJECTED DEMAND PHASE B: 4500 WATTS 2. CHECK CONDUITS FOR PROPER INSTALLATION, I.E. TIGHT CONNECTED DEMAND PHASE C: 18890 WATTS CONNECTIONS, PROPER FITTINGS, RUSTING, CREASING, BENDING, 109,F75 W. 106,622 W. PHASE C: 4000 WATTS 13,000 W. 11,500 W. ETC. REPAIR OR REPLACE AS REQUIRED. TOTAL 58240 WATTS 30: .54 A. 296.17 A. TOTAL 13500 WATTS 36.11 A. 31.9 A. 3. CHECK FOR BARE WIRING. COVER OR REPLACE AS REQUIRED. 4. CHECK FOR PROPER GROUNDING OF SYSTEM AND EQUIPMENT. CORRECT AS REQUIRED. 5. CHECK FOR CIRCUIT OVERLOADING AND/OR TRIPPING. REPLACE BREAKERS AND/OR FUSES AS REQUIRED. REDISTRIBUTE CIRCUITING OF EQUIPMENT AND/OR LIGHTING AS REQUIRED. 6. REPAIR ANY RUSTED AREAS ON EQUIPMENT CASINGS. REPAINT AS REQUIRED. PANEL NEW "B" LUGS 200 AMP DRAWN BY: 7. VERIFY THE SIZES OF THE EQUIPMENT IN FIELD AS SHOWN AND 120 208 VOLT 3 PHASE 4 WIRE M-L-O CALLED FOR - IF EQUIPMENT IS NOT SIZED AS REQUIRED, CONTACT MAIN B R E A . E R KEVIN THE ARCHITECT/ENGINEER. WIRE KT. LOAD BKR BKR LOAD CKT. WIRE AN ALTERNATE PROPOSAL SHALL BE SUBMITTED TO REPLACE ANY AND/OR ALL EXISTING SIZE USE 0. KVA SIZE A B C SIZE KVA NO. USE SIZE EQUIPMENT, IF THE EQUIPMENT IS DETERMINED TO BE IN NEED OF REPLACEMENT AFTER #12 LTG. STUDIO 1 1088 20/j 20/1 200 2 1 LTG. WALL SCONCES #12 THE INSPECTION AT THE JOB SITE. ALTERNATE PROPOSAL SHALL BE COMPLETE. #12 LTG. STUDIO 3 1216 840 4 LTS. JALLWAY #12 FURNISH AND INSTALL NEW ELECTRICAL EQUIPMENT INCLUDING ELECTRICAL PANELS "A", #12 LTG. STUDIO 5 704 704 6 LTS. ALLWAY NEW DISC SW "B" AND "c" AS SHOWN AND CALLED FOR. #12 60/40, NEMA 3R 60/401 NEW , NEMA C SW 3R FURNISH AND INSTALL TYPEWRITTEN PANEL DIRECTORIES AS SHOWN. #12 LTG. STUDIO 7 768 325 8 NIGH; EM LIGHTS #12 * #12 SPARE 9 1200 10 SIGN' GE #12 * CIRCUITS SHALL BE CONNECTED TO THE PANELS AND ARRANGED TO COMPLY WITH THE NEW AC UNIT #1 -------- NUMBERS SHOWN ON THE DRAWINGS. UNUSED CIRCUITS SHALL BE UTILIZED AS SPARES. #12 BREAK ROOM 1 192 900 12 RECPT T.V. #12 ON ROOF NEW ROOFTOP FURNISH AND INSTALL NEW TIME CLOCK. #12 RESTROOM/MECH 3 884 900 14 RECP STUDIO 114 #12 A.C. UNIT #3 PROVIDE ADEQUATE TEMPORARY POWER AND LIGHTING. #12 RECPT STUDIO 101 5 1260 900 16 RECP STUDIO 115 #12 #12 RECPT STUDIO 102 7 1440 900 18 RECP STUDIO 116 #12 N THE MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL FOUR (4) ROOFTOP AIR 3-#8, 1#6 GRD. 1/2"C. -$ •0- 3-#8, 1#6 GRD. 1/2"C. CONDITIONING UNITS. THE ELECTRICAL CONTRACTOR SHALL CONNECT THE NEW ROOFTOP #12 RECPT STUDIO 103 9 1620 900 20 RECP STUDIO 116 #12 W UNITS AFTER THEY HAVE BEEN SET IN PLACE. VERIFY TOTAL LENGTH OF CONDUIT AND 12 NEW DISC SW WIRING REQUIRED IN FIELD PRIOR TO BID. # RECPT STUDIO 104 _1 900 1080 22 RECP STUDIO 117 #12 #2 NEW DISC SW #4 ~ M 12 RECPT STUD10105 _3 900 60/40, NEMA 3R 60/40, NEMA 3R � N TIME CLOCK AND OTHER MISCELLANEOUS ELECTRICAL COMPONENTS SHALL NOT BE INSTALLED # 1080 24 RECP STUDIO 118 #12 W M ON THE TELEPHONE TERMINAL BOARD. #12 RECPT STUDIO 106 5 1 900 900 26 RECRj STUDIO 119 #12 Q LL -� MAINTAIN ALL REQUIRED CLEARANCES AT ALL ELECTRICAL EQUIPMENT AND COMPLY WITH #12 RECPT STUDIO 107 7 900 NEW AC UNIT #2 1080 28 RECP; STUDIO 120 #12 ON ROOF NEW ROOFTOP -� > _ N.E.C. ARTICLE 110. #12 RECPT STUDIO 108 119 900 1080 30 RECP STUDIO 121 #12 A.C. UNIT #4 > u Q FURNISH AND INSTALL NEW FIRE ALARM SYSTEM (IF REQUIRED). COORDINATE WITH #12 RECPT STUDIO 109 1 1080 900 32 RECP STUDIO 122 12 `� U = W LANDLORD. # F" Q m #12 RECPT STUDIO 110 3 1620 1080 34 RECP STUDIO 123 #12 Q m U TEMPERATURE CONTROL EXCLUDED FROM ELECTRICAL CONTRACT. 3-#8, 1#6 GRD. 1/2"C. J U F- #12 RECPT STUDIO 111 5 1260 36 SPAR #12 3- 8, 1 6 GRD. 1 2" ~ P Z CONTRACTOR SHALL NOTIFY THE ARCHITECT AND/OR ENGINEER OF ERRORS, OMISSIONS OR 12 RECPT STUDIO 112 7 1080 100 5000 38 # # / C 4 z J DISCREPANCIES BEFORE CONSTRUCTION OR FABRICATION OF AFFECTED WORK, OR, FAILING # /3 J SUCH NOTICE, SHALL BE RESPONSIBLE FOR CORRECTING SAME WITHOUT COST TO TENANT, #12 RECPT STUDIO 112 19 1080 4500 40 PAN L C FEED aQ ARCHITECT OR ENGINEER. - RECPT STUDIO 113 1 1108014000 42 � WORK SHALL INCLUDE START UP OF ALL SYSTEMS. PROVIDE ONE YEAR LABOR WARRANTY ON n;LN ENTIRE INSTALLATION AND ONE YEAR PARTS WARRANTY ON ALL EQUIPMENT SUPPLIED BY "*" INDICATES PANEL LOCKS PHASE A: 16545 WATTS SUB-CONTRACTOR. FURNISH ALL MANUALS, MAINTENANCE INSTRUCTIONS, AND WARRANTIES BALANCE 14.25%PHASE B: 17656 WATTS TO CONTRACTOR. PHASE C: 15140 WATTS 40,9 CONN, 5 W. 31,218 W.CTED DEMAND MOUNT SWITCHES 4'-0" ABOVE FLOOR UNLESS OTHERWISE NOTED. TOTAL 49341 WATTS 1131if6 A. 86.7 A. ALL CONDUITS FOR USE BY OTHERS SHALL BE CONTINUOUS, CONTAIN PULL STRINGS, AND HAVE PULL BOXES AS NECESSARY. EXTERIOR OF BUILDING SOLA SPACE NOTE: NOTE: EXISTING TO REMAIN ALL RECEPTACLE LOADS ARE BASED ON EMERGENCY/EXIT/NL L, HTING SHALL 4-#250 KCMIL, 1 #1/0 AL GRD., 2 1/2"C, I I I 180 WATTS FOR DUPLEX DEVICES AND BE ON SEPERATE CIRQ IT WITH BATTERY J 360 WATTS FOR QUAD DEVICES. BACK-UP. 4-#250 MCM AL, 1#1/0 GRD., 2-1/2"C. J EXISTING 200 EXISTING 200 „ ELECTRICAL SERVICE LOAD SUMMARY ALL PANEL LOCK DEVICES UST BE U.L. WITH 2100 ASW. APMP WITH 2100 AMP 4-#1 AL, 1#4 GRD., 1-1/2 C. LABELED-LISTED. FUSES TO REMAIN FUSES TO REMAIN LOAD ACTUAL N.E.C. N.E.C. DESCRIPTION CONNECTED DEMAND DEMAND LOAD FACTOR WATTAGE TC SIGN 750 125% 938 NOTE: ( O 200A. O 200A. LIGHTING 7,120 125% 8,900 * ALL ELECTRICAL EQUIPMENT AND MATERIAL ** SHALL B_ SUITABLE FOR INSTALLATION LIGHTING 4,725 SQ.FT. X 3W/SQ.FT. X 125% 17,719 * AND USE IN CONFORMITY WITH NEC 110.3(A)(1) 400 AMP 200 AMP 100 AMP NEW NEW NEW 120/208V. 120/208V. 120/208V. RECEPTACLES 1ST 10KW ® 100% 37,560 PNL "A" PNL "B" PNL "C" t REMAINING ® 50% NOTE: 400 AMP M-L-O M-L-O x rva:ot AIR CONDITIONING* 114 A. 208 x 1.732 41,069 SEAL AROUND ALL ELECTRICAL PENETRATIONS OF RUN NEW 200 AMP 120/208V. 3PH., 4W. SERVICE M-L-O HEATING* 0% FULL HEATING LOAD FIRE RATED WALLS PER NEC 300.21. 4-#250 KCMIL, 1 #1/0 AL GRD., 2 1/2"C, BREAKER DRYERS 40.8 A. 220 x 1 8,976 WATER HEATERS 360 100% 360 NOTE: MISCELLANEOUS - 100% - ALL ELECTRICAL WORK MUST COMPLY TOTAL CONNECTED 108,715 j TOTAL DEMAND 106,622 WITH NFA70. TOTAL AMPERAGE 296.17 HAYNES CHIDSEY - NOTES: NOTE: �I * USE GREATER LOAD OF THE TWO CONNECT ALL GROUNDING SYSTEMS, PHONE, OWNER ** SHOW WINDOW LIGHTING CALCULATED PER NEC ARTICLE 220-14(8)(1) TV AND SECURITY. LOW VOLTAGE IS BY ELECTRICAL CONTRACTOR AND SHALL CONSIST BUS.: 704.900.7730 OF ONE AT-5 AND ONE RG6 TO EACH I GROUND CEL.: 303.881 .7314 SALON ROOM FOR FUTURE USE. REQUIRED ELECTRICAL SERVICE EX 400A. TOTAL i NOTE: ALL GROUNDS IN EXISTING EQUIPMENT SHALL REMAIN WITH NO NEW WORK REQUIRED. RISER DIAGRAM NOTES 1. OBTAIN AVAILABLE FAULT CURRENT RATING AND PROVIDE NOTE: PROTECTION FOR MAIN CIRCUIT BREAKER AND ALL EXISTING METER AND DISCONNECT SWITCHES LOCATEB PROJECT: RANCH DEVICES. VERIFY DLOCATIONRIN FIELD.OF 2. TO REMAIN. 2. MAINTAIN ALL REQUIRED CLEARANCES PER ARTICLE SL-FL-253 110-26 NEC ATLANTIC VILLAGE 3. COPPER OR ALUMINUM IS ACCEPTABLE FOR SERVICE RUNS. VERIFY IN FIELD. RELEASE DATE 04/02/14 POWER RISER DIA GRAM REVISIONS: 1 BLDG. DEPT. REVIEW-5/23/2014 NOT TO SCALE DRAWING NAME ELECTRICAL SPECIFICATIONS N SHEET NO. E1 . 1 1 GENERAL NOTES: i 1. ALL CIRCUITS ON THIS SHEET TO PANEL V UNLESS NOTED OTHERWISE. PROPOSED NEW 2. REFER TO ARCHITECTURAL SHEET A1.5 FOR ADDITIONAL NOTES ELECTRICAL PANELS AND MOUNTING HEIGHTS. _ LOCATION A- ,-------, A A- c EXIT PLAN NOTES . o a A-19 A 31 i q_ !4-31 ° 90" 31 1O NEW PANEL T. 0 � A-23 i L E5'I� 3 q 2O NEW PANEL W. V♦ IA q-I'I � EQUIP. MECH. MENS j_ 35 j 2 A-15 O NEW PANEL "C'. AWL __J WAD i Hi h A A GFCI I A-117 VL_ J� A A-29 A-32 -21 A- A-45 q A-31 L------i & 0" 31 STUD; 109 / WOMENS [A299 A - ELECTRICAL NOTESDO i I i C A31 'i 9 A-27 ; ; 1 . ALL WORK SHALL CONFORM TO APPLICABLE FEDERAL, CERTIFIED BY. 29 STATE AND LOCAL CODES. 0\11111111/ BREAK RM. / STUDIO 108 �� oma_ 2. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY �DNSOC��' `� � � ► C SSARY PERMITS C-19 . � .• �. F •.•Oo ; /B_18I ' AND SHALL PAY ALL REQUIRED FEES FOR THIS WORK. �: - o A-25 q E 1 (�F 131 j ► `� ^ C-17 No. 60531 12 ► ► = 7k : - A- 37 A- 37 A-GF I C-�°j,v ; 1 A- 3. THE CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS 90" 90" A° 3 5485" 35 I -„ 33 1 GFCI AND REPORT TO SYMPATECO, INC., IN WRITING / TELEPHONE: p •. STATE OF00 1cw; C C-2 C I 1 1-800-652-1923, ANY DISCREPANCIES IMMEDIATELY UPON '.;�� ' .c�ORIDP. ' • ��� A ' C-2' q 27 DISCOVERY. sS/ONAI.� G�\ 37 f ► , GFCI r►rlll► A c 23 ; TUDIO 110 111 ; �__` 4. UNLESS OTHERWISE NOTED, ALL TELEPHONE, ELECTRICAL, ` 35 0 , CABLE & DATA LINE OUTLETS SHALL BE LOCATED 18" ABOVE THE ! � 37- -� STUDIO 111 If g 3— N. � FINISHED FLOOR. 3 12 i 9 11q33 t ' '� STUDIO 107 �� 15 5. UNLESS OTHERWISE NOTED, DIMENSIONS FOR ALL NEW WORK 35 A GFCI A 90" ARE MEASURED FROM FACE OF GYPSUM BOARD. DIMENSIONS STUDIO 112 ` q- 37 q 33 33 27 REFERRING TO EXISTING WORK ARE MEASURED FROM FACE OF DRAWN BY: 3 GFCI i q- 27A EXISTING FINISH. GFCI KEVIN CI i 35 0 35 33 25 A 6. ALL ELECTRICAL DIMENSIONS ARE TO CENTER-LINE. ALL 'HOLD' C-4 '®® / �'� ___ A n 90 DIMENSIONS ARE CRITICAL. 25 0 i ►it 25 7. CHECK WITH OWNER RE: LOCATION OF TELEPHONE AND ALARM I CLOSET , SYSTEM. ELECTRICIAN TO PROVIDE OUTLETS FOR THE DOOR / 14% ' ; STUDIO los CAMERA SYSTEM AND DVD PLAYER. ELECTRICIAN TO CONTACT 39 GFCI _ TELEPHONE CO. TO VERIFY THE NUMBER OF LINES COMING INTO 22M7_____ -_ ---- C-13 � THE BUILDING. PHONE LINE REQUIRED TO EACH STUDIO FROM JGFCI A- ---_-- ___--- ----- A- ; i 1 A- CENTRAL PHONE BLOCK. CLEARLY MARK STUDIOS ON PHONE 41 � GFCI ` A A 2sGFCl F5 I BLOCK FOR EASE OF CONNECTION UPON STUDIO RENTAL. C-s �` ♦1 30 28 CHECK WITH OWNER FOR NUMBER OF LINES. CONSULT SOLA 2 N A- _ 23 DEVELOPMENT MANUAL FOR ADDITIONAL DETAILS, SPECS AND rn 30 —�00, GFCI INFORMATION. STUDIO 113 1 , ' C-22 , W STUDI 121 F_- M i r sruDlo 12q i ��—` 8. ALL VISIBLE OUTLET COVERS TO BE STAINLESS STEEL. ALL W u N 41 I 41 A C 24 I A �'� OUTLET PLATES IN CABINETS AND NOT VISIBLE TO BE WHITE. Q d _ 30 28 I I STUDIO 105 % C-11 J Q 9011 A 41 q - q_ i 9. G.C. / ELECTRICIAN TO PROVIDE AND WIRE EACH STUDIO WITH _J > _ 2 A u 30 8 28 �� I _ > W (� III 9 TELEPHONE T 0 Z�Zz9 ' S OBE INSTALLED AND COMPLETED FROM EACH Q _ 14 A 41 _II - 26 A 23 STUDIO TO REAR OF STORE. G.C. TO LABEL ALL BREAKER AND Z p m 90" 32 9- 23 A TELEPHONE PANELS. P Q m v C-8 STUDIO 114 1 111 26 STI 10119 -� 21 A 10. ELECTRICIAN TO PROVIDE CONNECTION TO WATER HEATER Q z Q z 32 c-20 �� I' �I 9 IGNITOR. Q I 1 1 STUDIO 122 a 21 11: ELECTRICIAN TO PROVIDE CONNECTION TO STACKED N I ► ► -r i i i WASHER/DRYER UNIT, CONFIRM THE POWER REQUIREMENTS o` I ► j 1 / (; C-26 `� j j STUDIO 104 o I i / 1141. ; i W/ MANUFACTURER. SEE INSTALLATION MANUAL. 14 14 GF I 32A- 26NGF 26 I ► ► /���'�-♦ 12. G.C. TO VERIFY SECURITY CAMERA LOCATIONS AND MOUNTING Ir----:]Tvv G IC ]N / c-9oeoll 3110 FCI r--TZ:]Tv 4 0 - r_-12:31v ; ; 1 A- HEIGHT WITH OWNER PRIOR TO INSTALLATION. 16 `j 1 I I 34 �'I F 1 1 GFCI 21 C-10 _ �i'it `� _ C-18 ' 24 ill ; 19 C_7 _ 13. ELECTRICIAN TO PROVIDE 40 AMPS TOTAL TO EACH STANDARD / , I ♦ %I% `M% ► ► _ A 19 OR LARGE STUDIO (TWO 20 AMP CIRCUITS). ONE CIRCUIT IS STUDIO 115 0� , I `o// itIffGFCI AFF / 90DEDICATED TO OUTLET "C". DOUBLE STUDIOS REQUIRE 80 AMPS STUDIO 118 q (FOUR 20 AMP CIRCUITS). 16 ► I ETUDIO 123 %*. ► 1 1 I •�.� C i C-28 24 ; ► 19 14. G.C. TO INSTALL TELEVISIONS WITH CEILING MOUNTING 16 90" i 1 j BRACKETS AND CABLING. VERIFY WITH OWNER. CABLES TO A- 16 A 34 24 ► ► RUN TO DVD PLAYER IN THE LAUNDRY OR STORAGE ROOM. 34 34 q A 24q 24 I STUDIO 103 -- THREE TV'S PER CORRIDOR OR AS INDICATED. ELECTRICIAN TO °— - °1 PROVIDE OUTLETS. G.C. TO RUN CABLE FROM EQUIP. CLOSET I° 1s 45' GFCI 1 1 =!!:iA �� -_ TO ALL STUDIOS AND TIE UP ABOVE STUDIO CEILINGS. LABEL 1e / I 1 O N 12 EACH LINE WITH STUDIO NUMBER. 19 9 ELECTRICAL LE AIx , __--_-_-- -_-_-_-_ GEN D ------ ----- DUPLEX - 120V- 15-20 AMP - HEIGHT BY CODE 18 // / I 222 A- 22 15 A �' 15 q_ 17 - 17 ° 17 A- q q x rvn:o� A A- 17 eo _� � 4 UNLESS NOTED OTHERWISE ON PLAN. / GFCI e` GF q_ ``a GFCI - 17 GFCI AS REQUIRED BY CODE C-12 \\\\\� �® I STUDIO 15 GFCI 1 i �/ 20 / 2 4 QUAD - 120V -20 AMP - 24" AFF O.C. (IN CABINET) B 1F i � A- / / B UNLESS NOTED OTHERWISE. "B" OUTLETS ARE NOT i� STUDIO 116 GFCI L °1 BF I o`er_ _ SWITCHED. GFCI AS REQUIRED BY CODE. /// 22 q �0 5 - ®®�_® a of / 4t�� STUDIO 101 E E / STUDIO 102 ®�``` NLJH 3 -GANG -120V -20 AMP - 3 DUPLEX OUTLETS C-14 90" / C-1 C-3 E ELECTRICIAN TO LEAVE 3-0 FLEX @ 24 AFF HAYNES CHIDSEY 00, 811 20 �/ I c-5 C FOR HOOK UP TO OUTLET. OUTLET, BOX, WIRING OWNER A F - E, & COVER PLATE BY ELECTRICIAN. GFCI AS REQUIRED BUS.. 704.900.7730 9011 C-16 - �1 q q 9 „ BY CODE. OUTLET TO BE SWITCHED AS ALLOWED BY CEL.: 303.881 .7314 20 1 Y ELECTRICIAN, ENTRY 15 17 -� 17 ,� 17 DEDICATED "CDOUTB ET PER C RCUITSEE OWNER. ONE D DUPLEX - 12115-20 AMP - 24" AFF O.C. UNLESS NOTED OTHERWISE. GFCI AS REQUIRED BY CODE. E DUPLEX - 120V- 15-20 AMP - SWITCHED OUTLET TO t BE INSTALLED ON WALL @ 6" AFF AS NEAR TO FLOOR AS POSSIBLE. SWITCH TO LIGHT SWITCH. PROJECT: LIGHT SWITCH SL-FL-253 ELECTRICAL POWER PLAN TELEPHONE - (TYP.) CAT3 CABLING. 24 AFF O.C. ATLANTIC VILLAGE SCALE: 1/4°=V-0° UNL`SS NOTED OTHERWISE. RELEASE DATE 0 04/02/14 CABLE TV OUTLET REVISIONS: SECURITY CAMERAS (SEE ELECTRICAL NOTES) 1 BLDG. DEPT. REVIEW-5/23/2014 CEILING MOUNT TV'S - 21" SILVER/GRAY-CHECK WITH N�---] OWNER RUN CABLE TO DVD PLAYER LOCATED IN LAUNDRY OR STORAGE ROOM PROVIDE CATV OUTLET AND 120V. CEILING MOUNTED RECEPTACLES. DRAWING NAME i ELECTRICAL POWER PLAN ELECTRICAL POWER PLAN N SHEET NO. - 1 . 2 ......... x _ n PLAN NOTES: ONEW ROOFTOP A.C. UNIT #1 ON ROOF. EXTEND AND l CONNECT CONDUIT AND WIRING TO PANEL "A". ONEW ROOFTOP A.C. UNIT #2 ON ROOF. EXTEND AND " CONNECT CONDUIT AND WIRING TO PANEL "A". ONEW ROOFTOP A.C. UNIT #3 ON ROOF. EXTEND AND CONNECT CONDUIT AND WIRING TO PANEL "A". O4 NEW ROOFTOP A.C. UNIT 4 ON ROOF. EXTEND AND CONNECT CONDUIT AND WIRING TO PANEL "A". ONEW 60 AMP NEMA 3R DISCONNECT SWITCH AS REQUIRED. SEE SHEET E1.1 FOR FUSE AND WIRE SIZES. ii W� I I V0i CERTIFIED BY: \CENSE' No.60531 STATE OF e �i� • FtOR10P••' . � �� r � r � r i D RAW N BY: KEVIN I �I i O A- 3:yO A-13 O A-13 1 N Q1 WP/GFII WP/GFI qr WP/GFI IrrT- 5 5 i1r, W W 3-#6-1"C. TO 3 #6-1"C. TO . 04 M CKTS. "A"-8,10,12 CKTS. "A"-2,4,6 CKTS. "A"-7,9,1 LZ J > _ > J Q Z Q m � a m U � PZ a Z J N O i N rva:os A-1 WP/GFI 5 3-#6-1"C.TO CKTS. "A"-1,3,5 HAYNES CHIDSEY OWNER BUS.: 704.900.7730 CEL.: 303.881 .7314 PROJECT: SL-FL-253 ATLANTIC VILLAGE ELECTRICAL POWER PLAN-ROOF RELEASE DATE SCALE: 1/4"= 1'-0" 04/02/14 REVISIONS: 1 BLDG. DEPT. REVIEW-5/23/2014 DRAWING NAME ELECTRICAL POWER PLAN-ROOF ELECTRICAL POWER PLAN-ROOF N SHEET NO. E1 . 3 , �------------ -_ HVAC NOTES 1. EACH STANDARD AND LARGE STUDIO THERMOSTAT 18 GUAGE TO HAVE 1 DIFFUSER AND 1 AIR RETURN. AUX 2 N.O. S 18 GUAGE 2. EACH DOUBLE STUDIO TO HAVE 2 � MEN 1 –HOUR DIFFUSERS AND 2 AIR RETURNS. COMMON WALL 3. HVAC DIFFUSERS TO BE LOCATED AWAY Z AUX 1 N p TIMER FROM STYLING STATION/CHAIR TO __ Q8 _ PREVENT DIRECT AIRFLOW ON 12X12X6 BOX CUSTOMER. DIFFUSER TO HAVE s EXIT MANUAL CONTROL FOR ADJUSTING -J 13 130 130q s AIRFLOW. 18 GUAGE A A F 130q 130q LLJ= MECH. 4. G.C. TO VERIFY AND COORDINATE ALL SINGLE POLE EXTERIOR WOMENS 13 Q 11 EQUIP. MECHANICAL SHAFT AND DUCT W A 13 13 A PA O LOCATIONS. 24V. 6P J SIGN 013 OA BREAK RM. STU 101091 13 A –' CONTROLLER (� O A 13 13 A 5 REMOTE THOERMOSTAVIDE TIS SUM ENSORS O BE F TWO3 12 GUAGE ®F 11 2 LOCATED IN EACH STUDIO. VERIFY 18 GUAGE—� O13 c A 2 WITH OWNER. CERTIFIED BY: 6X6X6 BOX c 6 HALL 10A 3 3 ® LIGHTING NOTES 013 11 - w THREE POLE o LIGHTING 1 . ALL WORK TO STRICTLY COMPLY WITH ��`��`�N ID.IHp/��'%, A z 24V. Q 3 3 ....... ��, _} _j -- _ ALL FEDERAL, STATE & LOCAL CODES. �`�.�'�� L\CENSF'''�O CONTROLLER - ` 24V. R EC STUD O 108 ' PUMP /04 2. OWNER TO VERIFY WITH LANDLORD IF = Na 60531 EXTERIOR SIGNS ARE ON COMMON ® ELECTRIC CIRCUIT FOR BUILDING OR TOS'. STATE OF G 2 /06 BE ON SOLA CONTROLLED TIMER c '�)NNAU �18 GUAGE LOCATED IN EQUIPMENT # 2. S 3. CORRIDOR LIGHTS AND SCONCES TO BE 1 2 3 4 3 3 3 3 ON A TIMER. OVERRIDE SWITCHES AT ENTRANCES. 120V. SUPPLY 3 .� CIRCUIT 5 STUDI 111 FsTuc 344. G.C. TO PROVIDE EXIT SIGNS, FIRE DRAWN BY: LIGHTING CONTROL BOX WIRING STUDIO 112 STUD O 107 EXTINGUISHERS EMERGENCY 3 3 2 706 CY LIGHTS, KEVIN ETC. AS REQUIRED BY LOCAL CODES. NOT TO SCALE 13Oq EM 5. ALL EMERGENCY AND EXIT LIGHTS SHALL BE BUILDING STANDARDS AND --� CLOSET APPROVED BY OWNER. 3 3 7)(06 f® 6. EVERY FOURTH LIGHT IN THE CORRIDOR 4 6 EM s IS TO BE A NIGHT LIGHT PER CODE. 1 1 7. ELECT. TO VERIFY ALL LOCATIONS OF _ L_o los SCONCES AFTER BOXES HAVE BEEN s INSTALLED BUT BEFORE THE N 121 STU 10120 WIRING TA . T5 HAS LED IN CASE CHANGE S ARE WANTED.L w ��\\\\� MON ETH R '' (NL) Lu M 3 3 4 7 7 7 7 CEILING PLAN LEGEND W LL J Q = STUDIO 113 EM VERIFY ALL SELECTIONS WITH STORE OWNER W v 2 1 1 © J Q SYMBOL DESCRIPTION `� U ABX SENSORS. _jw R �; 0 00 c 6 ESTUD O 105 Q m V STUD 122 STUDI 119 2 OA RECESSED CAN LIGHT-HALO H991CT OR SIMILAR Q Z Z No . A " 2 S� STUDIE04] F•- Q 2'X 4' FLUORESCENT-LITHONIA GT8 GENERAL PURPOSE TROFFER- Q b1PMPART-NUM ER _ PRISM LENS-2 LAMPS-5000K FLUORESCENT LAMPS REVISION-CODE N~^x �. QUANTITY N PLAN SVMBOL 4 rill. O M2M-DESCRIPTI N r/d ICE iboM 5 SOURCE 7 7 7 7 _ NO ��:.. STUD O 114 C WALL SCONCE-66"AFF-USE 25 WATT COMPACT FLUORESCENT LAMPS 6 ® (120V). KAP DESIGN WILL PROVIDE THROUGH SOLA CORPORATE 11 Nc � •. 1 1 OFFICE: 303-377-7652 — I I com � STUDI 123 STUDI 118 (NL) 2'X 2' FLUORESCENT--LITHONIA PARAMAX PARABOLIC TROFFER 2PM3N WITH 6"WIDE U LAMP 9 CELL PARABOLIC LENS OR SIMILAR AUX 4 ® (NL)= NIGHT LIGHT 2 REA ` (NL) � � ` 5 5 (NL) 2'X 2' FLUORESCENT-- LITHONIA PARAMAX PARABOLIC TROFFER 7 7 7 7 EM 6 2PM3N -WITH 6"WIDE U LAMP 9 CELL PARABOLIC LENS OR SIMILAR A STUD O 115 (NL)= NIGHT LIGHT WITH EMERGENCY BACKUP ' �° �` EM __ 1 1 �'' zz C Xi® DUAL HEAD EXIT LIGHT AND STANDARD EXIT LIGHT (AS REQUIRED BY 2 2 C STUD 103 CODE). EXIT SIGNS SHALL HAVE BATTERY BACKUP. , (NL) j ® EXHAUST FAN-SHALL BE SWITCHED WITH ROOM LIGHTS AS REQUIRED. 4 4�®+ 4 1 F 4 EM CEILING SPEAKERS INSTALLED BY G.C. x TU L (TO BE TIED TO RADIO IN EQUIPMENT CLOSET r� la' -IAV G 5 5 OR LAUNDRY ROOM, CHECK WITH OWNER REGARD- � ro[IPl i g om ING SOUND SYSTEM.) STUDIO 116 STUDIO 102 o DRUM LIGHT TO BE DETERMINED 5 5 04 THERMOSTAT BACKPLATE DIAGRAM STUDIO :17] 1 1 1 1 X EXTERIOR EMERGENCY LIGHT TO BE DETERMINED H 00 STUDIO 101 WITH BATTERY BACK-UP AYNES CHIDSEY 1 OWNER NOT TO SCALE 5 5 5 Bus.: 704.900.7730 1 1 1 CEL.: 303.881 .7314 --------------- PROJECT: SL-FL-253 ATLANTIC VILLAGE ELECTRICAL LIGHTING PLAN SCALE: 1/4"=1'-0° RELEASE DATE 04/02/14 REVISIONS: 1 BLDG. DEPT. REVIEW-5/23/2014 DRAWING NAME ELECRICAL LIGHTING PLAN ELECTRICAL LIGHTING PLAN N SHEET NO. El . 4 h - 8 PLAN NOTES: EXHAUST FAN SCHEDULE 7­9 -- ONEW A.C. UNIT #1 ON ROOF. BALANCE SUPPLY AIR TO 2150 CFM UNIT PRESSURE DROP AND OUTSIDE AIR TO 540 CFM. MANUFACTURER MODEL CFM DRIVE WATTS/HP RPM VOLTAGE CONTROL NOTES NO. INCHES WC. OA 8"1 A0 F OA O NEW A.C. UNIT #2 ON ROOF. BALANCE SUPPLY AIR TO 2300 CFM g " EF-1 GREENBACK GB-071 M� 1/2" BELT 1.7 A. 1050 120 SWSWITCHH O i B 200 AND OUTSIDE AIR TO 575 CFM. U 410 8"0f 3 NEW A.C. UNIT #3 ON ROOF. BALANCE SUPPLY AIR TO 2480 CFM Z NOTES: F O AND OUTSIDE AIR TO 620 CFM. 24 p 01 COMPLETE FAN WITH INTEGRAL BACKDRAFT DAMPER(AS REQ.) & DISCONNECT SWITCH. O A A A A 10"� 10"0 04 NEW A.C. UNIT #4 ON ROOF. BALANCE SUPPLY AIR TO 2000 CFM 20 PROVIDE FACTORY ROOF CURB, BACKDRAFT DAMPER, BIRDSCREEN, DISCONNECT, ASSURE PROPER CLEARANCES ON ROOF. 125 O A A AND OUTSIDE AIR TO 500 CFM. g A A 05 NEW 3/4" CONDENSATE DRAIN SHALL BE RAN IN PVC TO CLOSEST ROOF J " DRAIN WITH P-TRAP. COORDINATE TERMINATION IN FIELD PRIOR TO BID. F A HVAC UNIT SCHEDULE 11 6 10"0 TOILET EXHAUST DUCT. TERMINATE THROUGH THE ROOF WITH APPROVED Ruir T -� 1 „� 8"o- t0 O MFR. AND NOMINAL SA OSAQ CLING CAPACITY HEATING CAPACITY CT CA Oalm- C APPROX. A 8 0CAP. VERIFIY LOCATION IN FIELD. MARK MODEL NO. TONS CFM CFM SENSIBLE TOTAL EER/ INPUT OUTPUT VOLT PHEVAP. FAN COMPRESSORS CONDENSER FAN CIRCUIT OR C 0" 0 NEW SMOKE DETECTOR IN RETURN AIR DUCT AS REQUIRED. VERIFY . WELOCATION IN FIELD. SMOKE DETECTOR SHALL ACTIVATE A VISIBLE AND v (BTUH) (BTUH) SEER/ BTUH BTUH FLA/HP QTY. RLA LRA QTY. HP FLA AMPS LBS. O 410 q ® B AUDIBLE SIGNAL 606.4.1. A.C. UNIT #1 RGS060HE 5 2150 540 38.0 49.0 13.0 115.0 90.0 208 3 1.9 1 26 128 1 - .48 26.4 596 12 300 08 4" DRYER VENTS SHALL TERMINATE AT EXTERIOR WALL WITH APPROVED OA 14"� 10"9s g"� VENT CAP. SEE DETAIL THIS SHEET. A.C. UNIT #2 HEIL RGS072 6 2600 650 60.0 70.0 11.0 120.0 96.0 208 3 1.9 - - 159 1 - 30 30.9 692 A 8"� 09 NEW WATER HEATERS. COORDINATE EXACT LOCATION IN FIELD. HEIL A.C. UNIT #3 RGS072 6 2600 650 60.0 70.0 11.0 120.0 96.0 208 3 1.9 - - 159 1 - 30 30.9 692 150 " 12"0 g"� 10"+n 12 0 10 ROUTE FLUE VENT FOR WATER HEATERS UP THRU ROOF WITH RAIN CERTIFIED BY: PROOF CAP. CONTRACTOR SHALL VERIFY TERMINATION POINT IN A.C. UNIT #4 NEIL 5 2000 500 48.0 __[59.0 13.0 115.0 90.0 208 3 1.9 1 26 128 1 - .48 26.4 596 FIELD. SEE SHEET P1.1 FOR FLUE DETAIL. RGS060HE g"0 A 8"fib11 TWO 10" HARD DUCT FOR COMBUSTION AIR RELIEF. ONE PIPE SHALL BE 22 TERMINATED HIGH IN CLOSET AND THE OTHER TERMINATED LOW. FURNISH70< -00 f 2 5 AND INSTALL APPROVED ROOF CAP AS REQUIRED. D HQ DIFFUSER/REGISTER SCHEDULE - - - - _-- C X "� X 00 12 3/4GAS PIPING DOWN THROUGH ROOF. CONTRACTOR SHALL TERMINATE �� � ��CENSF '•'�Q�*� B A 3/4--GAS PIPE TO EACH WATER HEATER COMPLETE WITH GAS COCK, •'• SHUTOFF VALVE AND PRESSURE REGULATOR. SEE SHEET P1.1 FOR WATER • No.60531 MODULE FACE BORDER 8 30 * w MARK SERVICE TYPE SIZEBACKPAN MFGR. & MOD. N TYPE PATTERN NOTES COMMENTS "0 HEATER DETAIL. _ " 24X24 8 B B 13 THERMOSTATS SHALL BE MOUNTED BEHIND THE DOOR IN BREAK ROOM. A SUPPLY SQUARE 24" X 24" 18" X 18" TITUS TMSA 3 - LAY-IN 4-WAY 2,4 8"o 225 12"0 225 O INLINE DUCT TEMPERATURE SENSORS SHALL BE INSTALLED AND TIED TO ;,�0 '•,. STATE OF THERMOSTATS. ���C` •.,,R�OR�pP,.` \ �� BORDER CORE AREA 24X24 'WONAL B RETURN SQUARE 24" X 12" SEE PLAN TITUS 23 RL 3 - LAY-IN - 5,10 - _­­ OA C NOTES: / A 33oAo "1. PROVIDE WITH AG-35-AA OPPOSED BLADE VOLUME DAMPER (RECT. 272RS & 23RL) B 16"0- 2. PROVIDE WITH MODEL EG EQUALIZING GRID DIFFUSER REGISTER TYPE 300 HVAC NOTES 3. PROVIDE WITH MODEL AG-95 OPPOSED BLADE VOLUME DAMPER (SQUARE) " 500 pi 1 -00 4. PROVIDE WITH MODEL AG-75 OPPOSED BLADE VOLUME DAMPER (ROUND) q E 24 24 4) DRAWN BY: 5. PROVIDE WITH TRM PLASTER FRAME 6. PROVIDE WITH RUSKIN MODEL CFD FIRE DAMPER 500 960 RETURN AIR q "o 50 2 1 30 7. PROVIDE WITH TITUS MODEL MPI37 INSULATED PLENUM " QUANTITY (CFM) 20" 4 "'150 1 . EACH STANDARD AND LARGE STUDIO (DO NOT SUPPLY FOR BLANK SECTIONS) 12 AIR QUANTITY (CFM) 22X22 14"0 225 8 o"o 4Xj TO HAVE 1 DIFFUSER AND 1 AIR RETURN. KEVIN 8. PROVIDE PREFAB PLASTER FRAME FOR MOUNTING " 8„yy 16 9. PROVIDE WITH MODEL AG-15-AA VOLUME DAMPER (RETURN RECT. 50F) DUCT CONNECTIONCORE AREA 2. EACH DOUBLE STUDIO TO HAVE 2 10. PROVIDE WITH MODEL DB OPTIONAL DIRECTIONAL BLOW CLIPS (8'-0" MAX FOR FLEX DUCT) DIFFUSERS AND 2 AIR RETURNS. 16"0 D p B 12"� 12" 3. HVAC DIFFUSERS TO BE LOCATED AWAY 30 600 7 12"Vsb -12' 7 14"� PREDIRECT FROM VENT AIRFONOLOW TO 2 X X 5 3 CUSTOMER. DIFFUSER TO HAVE B B MANUAL CONTROL FOR ADJUSTING 30 BACKDRAFT DAMPER A O AIRFLOW. TO BE SCREWED TO 3 0 80 18 180 " 24X 4 FLANGES IN PLENUM 12 0 4. G.C. TO VERIFY AND COORDINATE ALL 98' (DAMPER FURNISHED BY RESTROOM EXHAUST HOOD � 8' FAN MANUFACTURER.) c MECHANICAL SHAFT AND DUCT w CURB BY FAN SUPPLIER LOCATIONS. NOTE: LEVELED & INSTALLED 12 A 10"o 10"� A 12"� N FLEX DUCTS TO RUN BELOW BY G.C. w ce), � N BOTTOM OF JOIST X s q A c 12"05. G.C. TO PROVIDE MINIMUM OF TWO a 150 8"0 8" 150 REMOTE THERMOSTAT SENSORS TO BE J Q LOCATED IN EACH STUDIO. VERIFY = " O vJQ A 1 0 8 � > Lu 8" DIA. TOILET 30 8"0 WITH OWNER. _ = w EXHAUST PLENUM 8 B 8"o 0 Z 0 m 6"DIA. FLEX DUCT 3o A Q 00 V T 180 180 24X 4 J U F- � Q Z J s"� 300 24X24 24X24 6"DIA. FLEX DUCT B 8" F Q DRAWBAND Lr7 N STARTING COLLAR 2 4 B 24X "o o 1 80 TYPICAL EXHAUST HOOD DETAIL X X 2, B NOT TO SCALE ® A A 300 30 18 �L80 24X24 8" �" WALL THIMBLE WITH C s BUILT-IN HOOD C TERMINATION A CA 250 15 B 1 8" 50 DRYER EXHAUST 12" 21 0 1 "o 1 "o 8"0 14" 2 X24 10"o 12" 8" � D IV \ L 710 � B 8" 7 10"0 8-0--,,, " q 8 8"o 500 10"W 24X24 8"O lo A J 0 10 400 P25 1 "o 10"o BB A 400 400 8"0 L240XC2 250 24X24 4 -e-ADJUSTABLE VENT 8no EXIT HAYNES CHIDSEY OWNER BUS.: 704.900.7730 CEL.: 303.881 .7314 DRYER NOTE: PROJECT: 1. DRYER VENTING SHALL COMPLY WITH ALL OF SECTION 504. MAXIMUM LENGTH SL-FL-253 OF DUCT INCLUDING RADIUS SHALL BE 30 FEET. ATLANTIC VILLAGE 2. DUCTS SHALL NOT BE JOINED WITH SCREWS OR SIMILAR FASTENERS THAT PROTRUDE INTO THE INSIDE OF THE DUCT. 3. TRANSITION DUCTS USED TO CONNECT THE DRYER TO THE EXHAUST DUCT SYSTEM SHALL BE A SINGLE LENGTH THAT IS LISTED AND LABELED IN RELEASE DATE ACCORDANCE WITH UL 2158A. 04/02/14 REVISIONS: DRYERVENT DETAIL I BLDG. DEPT. REVIEW-5/23/2014 NOT TO SCALE DRAWING NAME MECHANICAL P MECHANICAL PLAN N SHEET NO. M1 . 1 , PLAN NOTES: O1 GAS PIPING SIZE BASED ON ASSUMED TOTAL LENGTH OF 125-0" AND PRESSURE 2" PSI TO EXISTING GAS METER (770K TOTAL)- 3 VERIFY DISTANCE OF PIPING AND AVAILABLE PRESSURE PRIOR TO BID AND REQUEST PIPING SIZE REVISIONS TO SUIT THE EXISTING CONDITIONS. SIZED PER NFPA 54 (NATIONAL FUEL GAS CODE) TABLE 6.2(c). ROOF TOP ROOF T❑ A/C UNIT I 3/8'0 LAG BOLTS 4' FROM O2 ROUTE GAS PIPE DOWN THROUGH ROOF TO WATER HEATERS. A/C OR FAN CURB FAN EACH CORNER & MAX 24' OC PROVIDE GAS COCK/SHUTOFF/PRESSURE REGULATOR AND SEDIMENT Z (MIN 18ga) — (MIN 3 PER SIDE) TYP ALL 0 o TRAP AT EACH WATERHEATER AS REQUIRED. MECHANICAL CONTRACTOR 4 SIDES RO❑PING SHALL SEAL ALL ROOF PENETRATIONS AS REQUIRED. J _ __ _��REFI ARCH O3 EXISTING GAS METER LOCATION. 3/4" 4 PROVIDE GAS COCK/SHUTOFF/PRESSURE REGULATOR AND SEDIMENT ACTUATED STL JOIST (770K) (2) POWDER TRAP AT A.C. UNIT AS REQUIRED. FASTNERS T&B 18ga x 2' STRAP @ 2 ' A/C SUPPORT STIFFENER L 2 O.0 C3 MIN. PER SIDE) FRAME. FRAME (REFI SECT B-B) TYP. ALL (4) SIDES SHALL BE 1 USE MIN. (2) PER WELDED, NOT SIDE FOR FANS BOLTED. O O 1/2" ROOFTOP UNIT ROOF SUPPORT DETAIL, (300K) MAI NW CERTIFIED BY: 3/8'x2 1/2' LONG I_AG �. BOLTS AT 12' O.C. WITH 1" FENDER WASHERS 3/4" QLICENSE 'iQO�ii 3/8" BRAIDED STAINLESS STEEL (470K) �' No. 60531 •O� CABLE ACROSS UNIT(4 REQUIRED) A/C UNIT EQUIPMENT PROVIDE URETHANE TUBING =-0 �k _ GASKET PRE-FAB CURB OVER CABLE AT UNIT. WOOD NAIL R STATE OF GALV. TURNBUCKLE FLASHING '�isS •. .. G� �� EXPANSION BOLTS FIBER CANT. AIC UNIT 3/8'x3' AT 18" D RAW N BY: O.C. WITH 10 FENDER WASHERS. / OUTSIDE AIR KEVIN INTAKE 18" MIJ. (240K) (120K) 3/8'x 1 1/2"0 N,-_—✓ EYE BOLT ANCHORED TO CURB NOTE: ANCHOR UNIT AND BASE TO WITHSTAND F.B.C. HURRICANE WIND FORCE REQUIREMENTS. 1/2" 1/2" (230K) (120K) ROOFTOP UNIT DETAIL, F1 04 4 4 4 W ch N W M IL t. r J > CONDENSATE DRAIN — PROVIDE ® > W U DEEP SEAL TRAP AND VENT Lu WEATHERPROOF DISCONNECT • 1-1 4" GAS T / Q Z Q BY ELECTRICAL CONTRACTOR SUPPLY PIPE J V H UNION Q Z RTU LUBRICATED PLUG VALVE Q OUTDOOR AIR 6" DIRT LEG INTAKE � Q PATE PIPE �i NC FLEX SEAL CONNECTION ROOF D (115K) RETURN DUCT GAS MAIN SMOKE DETECTOR TO SPLASH BLOCK OR (AS REQUIRED) SUPPLY DUCT ROOF DRAIN ROOFTOP UNIT SECTION, W#JZ N N TVDIO/ 4 HAYNES CHIDSEY OWNER BUS.. 704.900.7730 CEL.: 303.881 .7314 r PROJECT: SL-FL-253 ATLANTIC VILLAGE MECHANICAL PLAN-ROOF RELEASE DATE SCALE: 1/4"=1'-0" 04/02/14 REVISIONS: 1 BLDG. DEPT. REVIEW-5/23/2014 DRAWING NAME MECHANICAL PLAN-ROOF MECHANICAL PLAN-ROOF N SHEET NO. M 1 . 2 PLUMBING NOTES 1 . ALL PLUMBING WORK TO BE DONE BY A LICENSED PLUMBING EQUIPMENT SCHEDULE PLUMBING CONTRACTOR AND TO MEET ALL MECH. FEDERAL, STATE & LOCAL CODES. oel MAKE & MODEL NUMBER o 2LBY Ley MENS 1 n �`` 2 V. SINK 1 - - " • REM (OR APPROVED EQUAL) DESCRIPTION CAPACITY FUEL TYPE BTU/HR NOTES 3 F.D. WITH 2. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY 1 1/2" V. 2" LAY FD 1 r " W 2" W. EQUIP. FD TRAP PRIMER Z WATER HEATER LOCHINVAR COMMERCIAL WATER HEATER 85 GALLON WITH NATURAL GAS 150,000 1 1/ " V. 2" W. I 1 4 3 1 1/2" V. Q PERMITS AND SHALL PAY ALL REQUIRED FEES FOR EPN150-085 155 GPH RECOVERY A 100' RISE 4" 1 1/2" V. i y - 1 o 3 F.D. WITH WATER HEATER BRADFORD WHITE LAY q" L===VV,J TRAP PRIMER n _- � SALON SINK F , 1 F RESIDENTIAI. WATER HEATER 50 GALLON NATURAL GAS 40,000 OR APPROVED EQUAL 1t2" i D ,ii 1 1/2- V. r i -� i.l ii -� i� 3. THE CONTRACTOR SHALL FIELD VERIFY EXISTING (ylJiZ) 5o GALLON 12p V. 1 1 1 URI bL__�y / I.i i it '�i i i CONDITIONS AND REPORT TO SYMPATECO INC. IN HOT WATER BELL & GOSSEff 4 W. FD 1 2 2 1,,1/2- V. I 1 " 2 W. I N ,: r _ PLUMBING NOTES 1 . ALL PLUMBING WORK TO BE DONE BY A LICENSED PLUMBING CONTRACTOR AND TO MEET ALL 10 -0" CEARANCE FROM INTAKES 2" FEDERAL, STATE & LOCAL CODES. STAINLESS STEEL----,, WATER CUT–OFF MASTIC o 1 2 �� 3/4" 1/2- 0 1 1/4" 3 ■ CLAMPING RING � � 2. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY Z CL –_ " PERMITS AND SHALL PAY ALL REQUIRED FEES FOR _ _____ EQUIP.1/ THIS WORK. PREMOLDED PLICING CEMENT SINGLE PLY MEMBRANE ®FD r SINK PIPE SEAL ROOFING PATCH BY ROOFER I I 1/2" C.W. LAP SEALANT WATER TIGHT FLASH TO PIPE SEAL i & H.W. r r ...W/p� ° n F W F I I 3. THE CONTRACTOR SHALL FIELD VERIFY EXISTING IH SALON SINK C– W/D 1 ® -- ONDITIONS AND REPORT TO SYMPATECO, INC., IN ® WOMENS FD III 1 2 C.W. � L _ H & H.W. WRITING, ANY DISCREPANCIES IMMEDIATELY UPON LLIZ EX) ROOF DECK FD _W/D� 1�2K C. I I L– --J L`'--J _ DISCOVERY. EX) BAR JOIST W/D & H.W. 11 2 +rj 1" STUDIO 109 i 4. KEEP VENT HEIGHT WITHIN SPECIFIED DIMENSIONS. U 1 11/4"BREAK RM. ' 1 1 1/4- 1 1 STUDIO 108 5. KEEP ALL ROUGH PLUMBING WITHIN SPECIFIED cW cw DIMENSIONS. 777 VENT PIPE THROUGH R 1/4" 1 1 OF W W " 1 1 SALON SINK 1 /4 It 3/4" 3/4 i ; ►1 1/2" C.W. 6. KEEP ALL VERTICAL VENT PIPES WITHIN 1 1 DISPENSARY& H.W. x , UTILITY, LAVATORY AREAS & NOT IN 3/4" 1 1 1 FINISHED SHAMPOO AREA. IF VENT RUNS OUTSIDE CERTIFIED BY: 1/2" Co • WALLS, GENERAL CONTRACTOR MUST BOX IN. '� 1 3/4" 7. NECESSARY VACUUM BREAKERS ARE PROVIDED BY .`��\��..�.•11��� SINK 3 �1MfS 1/4» ��. ''\,\GENII 2" C W 1/2" C.W. i i 1 SYMPATECO, INC. TO BE INSTALLED BY PLUMBER, Q- ' p / H.W. 1 I ` �:' & H.W. SALON SINK & I ; ' AT TIME OF SINK HOOK UP. - _ _ No. 60531 SALON SINK SALON SINK » I 1/2- C.W. 1/2- C.W. I 1 SALON SINK –'0 & H.W.C.W. & H.W. & H.W. It 1 1/4 i » W & Hit 1 1/2 C.W. 8. SYMPATECO INC. SUPPLIES SINK WITH 4" TAIL ;� :• 11 1 ► & H.W. = O STATE OF I— VENTPIPE THRU ROOF DETAIL PIECE, SHAMPOO HOSE & SPRAY, HAIR STRAINERS, � •c�•.,, ,����«� ,, e,�,.\� STUDIO 110 1 HAIR TRAP & FAUCET FIXTURES. PLUMBER TO ��>'�'�+� ­11", \14, NOT TO SCALE STUDIO 111 STUDIO 107 SUPPLY CHROME "SWING" TYPE "P" TRAP, CHROME ���//111110I, ' (� STUDIO 112 SHUTOFF, CHROME FLEXIBLE WATER FEEDS & ALL 1/2" C.W. FITTINGS. ' & H.W. J 9. EXTEND ALL ROUGH PLUMBING FROM WALL. -AS 3 NOTED- ;iD RAW N BY:t i 1 1/4" 1 1/4 ------ ----- 1 STUDIO 106 10. PLUMBING CONTRACTOR TO VERIFY ALL FIELD SALON SINK 1 1/2" C.W. ' i SALON SINK MEASUREMENTS. KEVIN & H.W. 11 11 „ 1 CLOSET 1 1 1/2 C.W. & H.W. 11 . PLUMBER TO PROVIDE ALL ROUGH-IN PLUMBING � r 1 1 PRIOR TO INSTALLATION OF SHAMPOO CABINETS & 3/4" _ i►► RETURN AFTER CASEWORK INSTALLATION TO 3/4" _–ZZZ --_----- 3/4„ ' HOOK UP/ INSTALL SINKS AS NEEDED. 3/4" 6�' 1 12. PLUMBING CONTRACTOR TO VERIFY PLUMBING I> ' ' REQUIREMENTS FOR ALL FIXTURES & EQUIPMENT i STUDIO 121 STUDIO 120 } PROVIDED BY OWNER & SYMPATECO, INC. I SALON SINK 1 1 it &H.W.C.W. 11 i SALON SINK SALON SINK 1 1 1/2" C.W. sruDlo 113 1/2 C.W 1/2 C.W. 13. WALL THICKNESS MAY VARY FROM PLAN AS �. & H.W. & H.W. 1 1/4" i 1 & H.W. � � � � SHOWN DEPENDING ON LOCAL REQUIREMENTS 04 1 AND EXISTING CONDITIONS. 1 STUDIO 105 W M 3,777777221 /4" 14. PLUMBER TO PROVIDE PLUMBING SUPPLY LINE 04 M " SHUT-OFF PER PLUMBING RUN. PLUMBER TO WO �°? M 3 4 SHOW OWNER WHERE SHUT OFF VALVES ARE AND Q DE u. 1ZZZZZ�_-1-z_zzzzzzz 7Z 1 STUDIO 119 1 SHOW HOW VALVES OPERATE. J 9 = PEES OR PUBLIC USE SHALL t? � w 4 STUDIO 114 1 1 STUDIO 122 1 > W U 'lll 1 1 1 1 1 1 1/4" 1 1/ „ ;1� 15. ALL SINKS FOR EMPLO a 0 ca -� 1 SALON SINK SALON SINK 1 STUDIO 104 H SALON SINK BE A MAXIMUM OF 6-%2" DEEP AND MOUNTED WITH � z 1/2" C.W. 1 1 ' 1/2" C.W. 1/2 C.W. 1 i ► SALON SINK THE TOP EDGE A MAXIMUM 34" A.F.F. SINK DEPTH �, � U & H.W. 1 1 ► 1 & H. & H.W. ' 1 » 1 , » DOES NOT APPLY TO LAVATORIES. Q 38£ It 1 1/4 1 1 1/2 C.W. & H.W. Q � 16. ALL FLUSH VALVE HANDLES FOR THE WATER 3/4* B 3/4" CLOSETS SHALL FACE THE OPEN SIDE OF THE 04 kh. 3/4' ' ' ROOM. G.C. TO PROVIDE POWER FLUSH TOILETS. c X11 ; 1 1 11 3/4" r 17. G.C. TO HAVE WATER TESTED TO DETERMINE IF WATER SOFTENER IS NEEDED. SALON SINK 1 3 1 1 " ► SALON SINK SALON SINK I j 1/2" C.W. i i 1 1/2- C.W. 1/2- C.W. 1 i „ & H.W. ' `1 1 4" ; & H.W. & H.w. ? 1/4 1 1 18. G.C. TO PROVIDE GAS WATER HEATERS IF ' ' / ' ; ' & H W. AVAILABLE. LOCKINVAR. VERIFY SELECTION W/ STUDIO 115 1 1� FS-T UDI0123 STUDIO 118 1 1 1/4" OWNER. 1j STUDIO 103 1 13/4» ki 0 3/4" I 4 " 1 14" 1/4- �I RESTROOM FIXTURES I FI — — — j 3/ " 3/4 (VERIFY W/ OWNER) / W W 1 1/4" 3/4" ,. C.W. I , KOHLER LAV. SINK SALON SINK & H.W. j j " CW CW " " 1 1/4 1/2 C.W. 1 1/4 3/4" 3/ STYLE: BOLERO ROUND SELF-RIMMING/UNDER CNTR -----_-- INSTALL SINK UNDERMOUNT ONLY I & H.W. I 1/2" 1/2" 3/4" 3/4" ------ MODEL NO.: K-2610-SU -r �- GIAGNI LAV. FAUCET STYLE: GIAGNI SINGLE HANDLE POLISHED CHROME �I( � STUDIO 101 MODEL NO.: LL102-PC II( I 1/2- C.W. STUDI 117I � & H.W. -_ MIRROR x TIIDI08 STUDIO 116 L & H.W. TUDI al 1/2" C.W. 11 In 11 PROVIDED BY OWNER - INSTALLED BY G.C. SO 102 ,1a SOLID SURFACE COUNTERTOP L2 - SOLID SURFACE COUNTERTOP -�� SALON SINK SALON SINK 12" TILES WAINSCOAT SET @ A 450 ANGLE ON ALL WALLS, k 1/2" C.W. 1/2" C.W. 48„ A.F.F. RESTROOM TILE FOR PREMIUM RESTROOMS H.w'w' & H.W. ® HAYNES CHIDSEY �I VERIFY FINISH WITH OWNER. i OWNER .�� BUS.: 704.900.7730 PLUMBING PLAN — WATER SCALE: 1/4”=1—o° CEL.: 303.881 .7314 , PROJECT: I� I II SL-FL-253 VILLAGE ut ` RELEASE DATE 04/02/14 REVISIONS: II ' 1 BLDG. DEPT. REVIEW-5/23/2014 sl ILII jn DRAWING NAME PLUMBING PLAN - WATER PLUMBING PLAN -WATER N k .I SHEET NO. , � I . 2 1 1/2- 000l � ^ e I I PLAN NOTES. I 1 � n /2 ' e I / � O1 CONNECT TO EXISTING SANITARY MAIN AND VENT AS REQUIRED. (� 3 1 1/2- 2" I I e 1 1/2' 2 EXISTING 4" LATERAL SANITARY PIPE TO REMAIN. Z .� l'oo'- e i e 0 2" � 01-10" 1 ,/2"I 1 2" I I 3 EXTEND 4" VENT PIPING THROUGH ROOF WITH APPROVED CAP. /` 4" � � � O e I I 2" 0000, .0000' 1 e O4 COLD AND HOT WATER PIPING TO WATER HEATER AS REQUIRED. e WALL I 1 1 1/2- le e » I C.O. � » / 1 e 5 NEW MAIN SHUT-OFF VALVE. J e 2` e � W TRAP ' I I » O 1 1/2 � e 3" 1 � PRIMER SALON 11 1/2 1 e O8 EXISTING COLD WATER MAIN TO REMAIN. VERIFY LOCATION IN FIELD. z (tee 1 / SINK 1 1 1 2n I 1 ee a 3" n SALON 1 1 1 1/2n O7 CONNECT TO EXISTING COLD WATER MAIN AS REQUIRED. / 1 I 1 1/2n 2 SINK i 1 I n I I 11/2" e I I / 1/2- 2" 2 M.S. 3" e 1 1/2 �� I 3" SINK 1 LAV 2" � e I SINK e 2" SALON " 2" SINK 1 1 1/2" 1 1/2 I e � roo� „/2"2nn 1 e 2" 3" I 1 1/2"1 !4" 1 1/2" sI I » I 2 SALON 1 1/2 " SINKCERTIFIED BY: " �� LAV 1 " WD• � e I 3 SALON1 1/2 2e W.C. F.D. I 2 e I 2" SINK LAV W/ TRAP I e SINK 1 " n e 2" 4n PRIMER 3" I 4n 1 1/2 I / 1 1 2" 2 2r i\`�,�►I�I I J i���,/ 1 " � 1 / 4 » I 1 n � HOCK LAV e 2 1 4 1 e " 1 1/2 3" �Ap� 2n ti������Ci.�\cENSF'•.;�®�/� e I 2» URINAL SALON SALON I 1 " 1 2" " e o I N0.60531 =_ 1 1/2 1\ 2» 1 1/2 1 SALO � e 1 1/2" V I e 3» 2" n n SALON SI K 1 1 1/2 '� 11 1/2- 2" e W 1 1/2nl 4 3 SINK I � I OF UJB 11 1/2" e 4" I e 1 SALO I 1 1 2" e n I ' ATE��eae,. � .��w SINK N I 2" 1 1/2"'' SINK /� rel 1 1/2 ��1� C�R..� 1 II » SINK I WALL 1 '�/� /ONA1� 3 F.D. 2 1 C.O /llillll�� 1 4" I W/ TR e SALON SALON I 1 1/2" PRIME e1 1/2" 2» " SINK 1 INK 1 SINK 1 � ! 3 " � 10000, I 2» " 3 SALON 2" e " 3" e 4 2" 2" SINK I " SI K e � 1 1/2 SALON 3" 1 1/2"l 1 1/2 e D.F 2"/ 2" 11 1/2" 3» 2n I SINK 3" 2" 1 � " 3" /I �� DRAWN BY: 4" 1 1/2 3» O SALON SINK e I 4" „1 KEVIN 1 SINK I 1 � I 1 1/2 W.C. 4" 1 3" SINK 1 1/2- 1 1/2" e� 1 1 n o n 4" " SALON W.C. 2 1 1 1 1/2- 1 1/2- 3 SINK „ ISALON I I 1-000 SINK SINK 1 W.C. 2 SALON 10000, 3" 1 3/4" 1/2" 1/2" 1 1/4" 3" " I SINK 2 SALON SINK / 4" 4" 3 4" 1/2n 4 " SINK 2" e `1/2" / 2 n n 3/4- 1 2 1 / / 2" 1 3/4" 1r 3" WALL 1 1/2- 1 3n " N 100 3n C.O. 1 1 1/2- C.O. o 4" W M SINK H M SINK n ILII I N 1 1 1/4" /2 1/2 2" I M 1/2 SINSALOK 1 " 1/2 / 1 SINK N J IL " 1 1/4- \ J > � , 2 1/2 1/2n1/2" - / n 3/4 " 2" > W / 1/2- M.S. 1/2n HW CW` 3/4" SNKN \\ ~ OD Lu m / " 3/4" �`�- a m V n 1/2W/D SINK CWHW 3/4" 3/4 1 1/4" lool, 1/2'k� 1/2" F4Q V Z » W/p " 1/2" 1 1/4 SINK SALON J lz W.C. 1/2- 3/4" 1/2- 1/2-/2F Q 1/2" 3/4" 1/2" - �,' Q �-.• LAV URINAL N `J �---0 1/2?" 3/4" SNKN o 1/2n /' 1/2n 7 1/Z" /2n SINK NOTE: 1. ALL FIXTURES DISCHARGING DOWNSTREAM FROM A WATER 1 1/4" 1 1/4" SINK CLOSET SHALL BE INDIVIDUALLY VENTED PER 901.2 1/2" 2. REDUCED PRESSURE ASSEMBLY BACKFLOW PREVENTERS ARE 1/2" SINK N 1/2" H CW 3/4" REQURIED TO BE INSTALLED WITH ALL SALONS. 3/4" " 3/4" HW SALON 1/Zn 3/4 N SINK CW SINK TYPICAL PLUMBING SANITARY ISOMETRIC. 1/2" 3/4" SINK 1/2" 1/4• ?-0" / S LON SALON 1 1/4" SI K 1/2- 3/4" SINK 1/2" D.F. 1 1/4" SALON / ' 3/4n 1/2" SINK HW LAV. 44- 1/2- 1/2- 1/2n CWS 3/4" 1/2" 3/4" 3/4" 1 1/4" 1/2" 1/2" W.0 SALON SINK W.C. 1/2 1/2- y W.C. IT SALON/2» SALON W'C' SINK 3/4" SALON SINK 3/4" SINSALOK 1/2" 1/2n 3/4" Z " 3/4" x ava:o� SALON 3/4 CW SINK W 3/4n HW CW 1/2" 1/2" SINK 1/2- SINK 1/2" 3/4" Lc 3/4" 3/4" 1/2" 1/2" SALON SINK LZ 3/4" 1/2" 1/2" SALON HAYNES CHIDSEYOWNER SALON 1/2- 1/2" 1/2- SINK SINK 1/2" BUS.: 704.900.7730 SALON BVALVES RANCHES ALL OFF OF 1/2" SINK SALON CEL.: 303.881 .7314 SINK MAIN (TYPICAL) 1/2" SINK SALON SINK 1/2" 1/2" 1/2" 1/2- SINK /2nSINK PROJECT: SALON SINK SINK ATLANTIC VILLAGE 1/2* 1/2" RELEASE DATE NOTE: SALON 04/02/14 ALL PIPING ABOVE CEILING SHALL BE CPVC. SINK REVISIONS: ALL BRANCH PIPING SHALL BE PEC'S. 1 BLDG. DEPT. REVIEW-5/23/2014 TYPICAL PLUMBING WATER ISOMETRIC, 1/41 - 1'-0' DRAWING NAME PLUMBING PLAN - RISERS PLUMBING PLAN-RISERS N SHEET NO. P1 . 3 I APPLICABLE CODES EXISTING SHELL ' BUILDING CODE: U ------ 2010 FLORIDA BUILDING CODE Z PLUMBING CODE: C� 2010 FLORIDA PLUMBING CODE Z 0 ® ;----- L-----J ELECTRICAL CODE: J oo r- 2005 NATIONAL ELECTRICAL CODE (NEC) UJ Amo =_ r MECHANICAL CODE: ® O i `= i i 2010 FLORIDA MECHANICAL CODE -- w v w V U L.-___J I L____J L----J FIRE/ LIFE SAFETY CODE: 2010 FLORIDA FIRE CODE ACCESSIBILITY CODE: 1 1 2010 FLORIDA BUILDING CODE 1 1 1 I I i ENERGY CODE: 1►t CERTIFIED BY: FLORIDA ENERGY CODE FLCCSB v.4.0 ► I , 1 GAS CODE: \����� 0. HO .......... ZZAZZ i ; l8E 2010 FLORIDA FUEL GAS CODE) �`�.``Z` •' `CENSE•'•. O �. 11 D — — CONSTRUCTION TYPE CLASSIFICATION: ' No.60531 TYPE II—B—SPRINKLED STATE OF :•��\ i ► ��''�SS/ONAL r 01 01 i , I ► ► PROJECT SUMMARY DRAWN BY: 101 r _ KEVIN - ------ ---- Proposed Use: Salon ►i ' , Owner's authorized Agent: Jansen Gehring Phone # 317-259-7000 ► ; ► Owned by a Private Owner ►� Code enforcement: Parker ► I ' J Lead Design Professional Matt Holbrook LliLL! Code 2010 Florida Building Code I + Gross project area - 4,725 SF Primary Occupancy - Business (salon) V) ;i 0 Secondary Occupancy - None CNI ® t , ► ! z Special Occupancy None os Mixed Occupancy -None w V) Allowable Height (existing building shell approved by original building permit- CO Mw r ► X tenant build-out does not alter height) a A U ► LU Fire protection Requirements w v UExisting 1 hour separation provided between adjacent vacant suite O v J Q - Roof system -Non Combustible = W O O Bearing walls -Non Combustible a m c, Structural Frame -Non Combustible Non bearing walls -Any Material a Q J ► , ; ; Life Safety Requirements a Q Emergency Lighting T r ► ,i � `3�E ii 1 + g Y g g - Yes � N ► ► ► _ ► ► + Exit Signs - yes 11 � ► Fire alarm - yes - %►1 Smoke detection System - yes ► 1 ► 1 Panic Hardware- NO Exit requirements for occupancy of 47people (1 per 100 SF) 1 � ► Minimum Number of Exits (2 req'd- 2 provided (shown on plans) Allowable maximum travel distance 100 ft (table 1004.2.4)- maximum travel distance 100 ft Required distance between exit doors- 48ft' (half of space diagonal) provided ► ! 68ft front to back B occupancy 47 occupants Exit width required (44" minimum) - 60" provided. Structural Loads — — -- Approved by original building permit- tenant build-out does not alter building structural system. Plumbing Fixture requirements a B occupancy (47 people) -_------ ----- _------ -_--- -------- --------- 1 male and 1 female water closet required - 1 Male and 3 female water closets �', ------ provided +1 urinal I 1 male lavatory and 1 female lavatory required - 1 male and 2 female lavatories provided. N TUD:os 1 Drinking Fountain required - 1 drinking Fountain provided. 01 Accessible Parking approved by original building permit- tenant build-out does not alter parking on -- site. Special approvals N/A HAYNES CHIDSEY Q Electrical Summary OWNER Reference sheets E1 .1 and E1 .2 for electrical tables. (prescriptive compliance) BUS.. 704.900.7730 ® CEL.: 303.881 .7314 oil Mechanical Summary Reference sheet M1 .1 for mechanical information EXISTING SHELL PROJECT: SL-FL-253 ATLANTIC VILLAGE RELEASE DATE 04/02/14 REVISIONS: 1 BLDG. DEPT. REVIEW-5/23/2014 DRAWING NAME LIFE SAFETY PLAN LIFE SAFETY PLAN N SHEET NO. LS1 . 1