372 10th St 2014 HVAC CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Application Number . . . . . 14-00001133 Date 7/17/14
Property Address . . . . . . 372 10TH ST
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . RES SF DISTRICT
Application valuation . . . . 0
-----------------------------------------------------------------------
Application desc
1 cu 1 ahu
------------------------------------------------------------------------
Owner Contractor
-
------------------------
-----------------------
FLETCHER TRUST, JULIA DONOVAN HEATING & AIR
800 GRAYDON AVE B3 315 SIXTH AVENUE SOUTH
NORFOLK VA 23507 JACKSONVILLE BEACH FL 32250
(904) 241-3785
-----------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee 95 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 1/13/15
----------------------------------------------------------------------------
Special Notes and Comments
STICKER FOR OVERCURRENT PROTECTION MUST
BE ON A/C EQUIPMENT PRIOR TO
INSPECTION. FAILURE TO COMPLY WILL
RESULT IN A FAILED INSPECTION AND
REINSPECT FEES . NO EXCEPTIONS .
-----------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
---------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 95 . 00 95 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 99 . 00 99 . 00 . 00 . 00
PERMIT IS APPROVED ONLV IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph (904) 247-5826 Fax (904) 247-5845
fOB ADDRESS: , 01�1 ST PERMIT#
PROJECT VALUE $ 5 DOO ARI# q y7 Q S�( REQUIRED
Air Handling Equipment Only y Air Handling Unit & Condenser Condenser Only
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit 2-.' -_
Heat: Unit Quantity I BTU's Per Unit Zy oo6Seer Rating
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
its application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name --�J V�� PETcnex Phone Number 19 S - (W 7b
Mechanical Company !Jo>joyA,J Nl ar Office Phone AI3IKS' Fax 9141 37 qr
Co. Address: 3j s: 61- ANf .S City -f;A State-El—Zip 3Z2 0
License Holder(Print): ► �1 v� �d Iv�DfAj State Certification/Registration# -�G03 � J
Notarized Signature of License Holder
W.4 RD TOMPKINS Before me this day of v I 20 _
•; Commission#FF 040399
E100 July 29,2017 Signature of Notary Public ✓10
liMWU lTroyFeinI..mOWW.7019
1 Summary Summary ect Job:
+4+ wrightsoft Pro Date: 7116114
Entire House By: Brandon Zaharie
Donovan Heat & Air
315 6th ave south,Jacksonville Beach, FL 32250 Phone:241-3785 Email:brandon@donovanac.com
Project • •
For: Fletcher
372 10th St,Atlantic Beach, FL 32233
Notes:
Design Information
Weather: Jacksonville Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 39 'F Outside db 95 'F
Inside db 68 'F Inside db 75 'F
Design TD 29 'F Design TD 20 'F
Daily range L
Relative humidity 50 %
Moisture difference 53 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 13919 Btuh Structure 11729 Btuh
Ducts 2799 Btuh Ducts 5690 Btuh
Central vent (12 cfm) 370 Btuh Central vent (12 cfm) 255 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 17088 Btuh Use manufacturer's data n
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 17674 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 1 (Average) Structure 197
8 Btuh
Ducts 3 Btuh
Heating Cooling Central vent (12 cfm) 420 Btuh
Area (ft2 1152 1152 Equipment latent load 3031 Btuh
Volume�ft-) 10368 10368
Air changes/hour 0.57 0.23 Equipment total load 20706 Btuh
Equiv.AVF (cfm) 98 40 Req. total capacity at 0.70 SHR 2.1 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade Trade
Model 25hbb324c Cond 25hbb324c
ARI ref no. 6937989 Coil fv4cnf002
ARI ref no. 6937989 15 SEER
Efficiency 8.5 HSPF Efficiency
Heating input Sensible cooling 15747 Btuh
Heating output 22384 Btuh @ 47'F Latent cooling 6749 Btuh
22496 Btuh
Temperature rise 27 'F Total cooling
Actual air flow 750 cfm Actual air flow 750 cfm
Air flow factor 0.045 cfm/Btuh Air flow factor 0.043 cfm/Btuh
Static pressure 0 in H2O StatiLoadcse sensible heat ratio 0.8sure 5 in H2O
Space thermostat
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
wrightsoTt Right-Suite®Universal 7.1.01 RSU05996 2014-Jut-16 17:30:51
Page 1
ACIP. C:\Users\Sales\Documents\Wrightsoft HVAC\2Ton.rup Calc=MJ8 Orientation=N