1 Fleet Landing Blvd # 784 HVAC CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
Application Number . . . . . 14-00001184 Date 7/25/14
Property Address . . . . . . 1 FLEET LANDING BLVD
Tenant nbr, name . . . . . . UNIT 784 BLDG 700
Application type description MECHANICAL HVAC ONLY
Property Zoning . . . . . . . PLANNED UNIT DEVELOPMENT
Application valuation . . . . 0
----------------------------------------------------------------------------
Application desc
1 cu 1 ahu
----------------------------------------------------------------------------
Owner Contractor
------------------------ ------------------------
NAVAL CONTINUING CARE DAVID GRAY HEATING AND AIR INC
FLEET LANDING 6491 POWERS AVENUE
1 FLEET LANDING BOULEVARD JACKSONVILLE FL 32217
ATLANTIC BEACH FL 32233 (904) 724-7211
----------------------------------------------------------------------------
Permit . . . . . . MECHANICAL HVAC PERMIT
Additional desc . .
Permit Fee . . . . 87 . 00 Plan Check Fee . 00
Issue Date . . . . Valuation . . . . 0
Expiration Date . . 1/21/15
----------------------------------------------------------------------------
Special Notes and Comments
STICKER FOR OVERCURRENT PROTECTION MUST
BE ON A/C EQUIPMENT PRIOR TO
INSPECTION. FAILURE TO COMPLY WILL
RESULT IN A FAILED INSPECTION AND
REINSPECT FEES . NO EXCEPTIONS .
----------------------------------------------------------------------------
Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00
STATE MECH DBPR SURCHARGE 2 . 00
----------------------------------------------------------------------------
Fee summary Charged Paid Credited Due
----------------- ---------- ---------- ---------- ----------
Permit Fee Total 87 . 00 87 . 00 . 00 . 00
Plan Check Total . 00 . 00 . 00 . 00
Other Fee Total 4 . 00 4 . 00 . 00 . 00
Grand Total 91 . 00 91 . 00 . 00 . 00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904) 247-5826 Fax (904) 247-5845
JOB ADDRESS: �Iee� �„`� 41,) �. , /J-J�4�I� h���. Ft �22 3 3 PERMIT#
-,Ib(, Q�.; 1�;� — U,,,+ �8y
PROJECT VAL UE $ 3,11 c G ARI# , 7 Q 6? REQUIRED
Air Handling Equipment Only XAir Handling Unit & Condenser Condenser Only
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit /• S
Heat: Unit Quantity i BTU's Per Unit = Seer Rating /
Duct Systems: Total CFM;=. REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty, Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
#Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence wit. .; -six month period or work is suspended or abandoned for six months.I hereby certify that I have read
this application and know the same to be true and correc. All provisions of laws and ordinances governing this work will be complied with whether specified or
not. The permit does not give authority to violate the pr-,wissions of any other state or local law regulation construction or the performance of construction.
Property Owners Name aD Q Phone Number 2'16 -Me,
Mechanical Company Da V-, CJS,_ Q � �r. ti.c Office Phone Fax
Co. Address: 6�q/ ZC1Wkfl v41Pr.02e City )1e State C-C Zip Ig 21
License Holder (Print): State Ce ification/Registration# CAc 181 q8Y,
Notarized Signature of License Holder
orA- Notary Public State of Florida Before me this 244 day of Jim 20 _
LaSheica Wilson p
,� ' My Commission EE050523 Signature of Notary Public
or Expires 01/0e/2015
Jul. 24, 2014 10: 19AM No. 4145 P. 3
` r
Certificate of Product Ratings
AHRI Certlfled Reference Number: 5358269 Date: 7/24/2014
Product:Split system: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: GSZ130181A*
Indoor Unit Model Number: ARUF18B14A*
Manufacturer:GOODMAN MANUFACTURING CO„LP,
Trade/Brand name: GOODMAN,JANITROL,AMANA DISTINCTIONS, EVERREST,ONE HOUR AIR
CONDITIONING AND HEATING, ENERGI AIR
Series name:GSZ13
G
Manufacturer responsible for the rating of this system Combination Is GOODMAN MANUFACTURING CO., LP.
Rated as follows In accordance with AHRI Standard 2101240.2008 for Unitary Air-Conditioning and Air-Source
Heat Pumpp Equipment and su
>3 bjOct to verification of rating accuracy by AHRI-sponsored,Independent,third
partytea Et ..
.. .......,.. ............•.. . ............. . ...,'.;....,r.'::::•':'... LFI,.
..... .............^................J.....t...i ..i. •..,). .'.S:!..;. .,.;;.,.•... .!�:,' •.;)(-•:;1:1`1:'1"I.G :ih:'..t:^.
;
r ' .......
.lit
411 _
5
COO Iflt
:.. ... ..',,•, ' ,..'. Q. :'`':':.:':;'. -
'
El
..,,..:w Y.I..J,...t, 1e 1..t.r.r.1:..........:..... ......'._......,....:t:..::'..,. ....,.{,(.... ,....t r:;,::i!w{`•' .,In! ,y<:
','.,,,try.,., ,..,l....)u.v._. r:fr•.................T....J..... ..... .. ..::'::":: ,.....r r.. :,1 f..�:�
•i•.)
l
In'
�a
t 0fu1•'
1
...::.......,,..........................,... .a........... .. .. ..... .... :...... •.,. - is���>
�:''R t H�1tb ..:. .... .. .. . .. ....R4M V
Heating Capacity(13tuh)G 17 F: 10500
Ratings followed by an aetedek I)fndkata a VOlunuo relate of preNousiy publiahed data.1101989 accompanied with a WAS.which indicates an Involunlary renis.
DISCLAIMER
AHRI does not endorse the products)listed on this cettlllcate and makes no represenlapons trrarrenlles or guarantees as to,and assumes no responsibility tor,
the prodact(s)listed on tills CerpBcate.AHRI expresstydiscialms all liability for damages of any Idnd arising out of the use or performance of the producl(s)r or the
unauthorized alteration of data listed on this ceru scale.ce►tined ratings are vagi only for models and configurations listed In the
directory at www.ahildirectory.org.
TERMS AND CONDITIONS
This Certificate and its contents are proprietary products of AHRI,Tkls Cettlficate shall only be used for Individual,personal and
conn4ennat reference purposes.The contents of this Certificate may not.In whole or Ill part,be reproduced;Copied;4lsaeminatad
l, AM
entered Into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's Indlvldual, AIR,CONbMONING,NEATINA,
personal and confidential reference. A REFRIGERATION INSTITUTE
CERTIFICATE VERIFICATION
The Ihlotmation for the model Nte4 on this certificate can ba verified at www.ahildirectory.org,dick on"Verify Certiffoale-link we make Lire beuee"
and enter the AHRI Cerdfled Reference Number and the date on which the cellift"le was Issued,
Which Is listed above,and the Certi lcate No.,which Is listed at bottom dghL i 1i',.; {'"°4"J""''°
C'ER'TIFI'CATE IVO.: 13050882445678B8BT
®2014 Alr-Conditloning,Heating,and Refrigeration Institute