Loading...
411 N Ocean walk Dr 2014 HVAC C, CITY OF ATLANTIC BEACH s 800 SEMINOLE ROAD J ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 14-00001188 Date 8/04/14 Property Address . . . . . . 411 N OCEANWALK DR Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1CU 1 AHU ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ SWANSON CARL A DONOVAN HEATING & AIR 411 OCEANWALK DR.N. 315 SIXTH AVENUE SOUTH ATLANTIC BEACH FL 32233 JACKSONVILLE BEACH FL 32250 (904) 241-3785 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 103 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 1/31/15 ---------------------------------------------------------------------------- Special Notes and Comments STICKER FOR OVERCURRENT PROTECTION MUST BE ON A/C EQUIPMENT PRIOR TO INSPECTION. FAILURE TO COMPLY WILL RESULT IN A FAILED INSPECTION AND REINSPECT FEES . NO EXCEPTIONS . ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due - ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 103 . 00 103 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 107 . 00 107 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 I l c� r,r /I � I 1Ph'(904) 247-5826 Fax (904) 247-5845 FOB ADDRESS: A 1` e \ WOA�� v PERMIT# PROJECT VALUE $ 4610 ' ARI# (.1c352-f53 REQUIRED Air Handling Equipment Only fflAir Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating REQUIRED Duct Systems: Total CFM REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit 3- S r' Heat: Unit Quantity ( BTU's Per Unit' TO-50 Seer Rating_ REQUIRED Duct Systems: Total CFM FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read Tis application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name cj�,,r l ,; a-0S 0T,N Phone Number q SL - I Mechanical Company �nr-JOJ,L,J 1ACInr -i Arr Office Phone P4137ff— Fax aY13-7qS-- Co. Address: 1315 V11:� r,4c S City t x State Zip F/31-130 License Holder(Print): W � ''a'''^ JG��✓"" Sta e Certif n/Registration# p G0 3q-7 61 Notarized Signature of License Holder �� day of L� 20 �q RICHARD TOMMINS Before me this «: Commission#FF 040309 S51 1* Expires July 29,2017 Signature of Notary Public oc ,�,.`'� Bonded TNu Troy Feil Ineurenoe W0,185-M19 Job: + wrightsoft Project Summary By: a don Zaharie Entire House Donovan Heat & Air 315 6th ave south,Jacksonville Beach, FL 32250 Phone:241-3785 Email: brandon@donovanac.com For: SWANSON 411 OCEAN WALK DR N,ATLANTIC BEACH, FL 32233 Notes: Design Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 'F Outside db 95 °F Inside db 68 'F Inside db 75 °F Design TD 29 'F Design TD 20 °F Daily range L Relative humidity 50 % Moisture difference 53 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 17933 Btuh Structure 15831 Btuh Ducts 6147 Btuh Ducts 12188 Btuh Central vent (33 cfm) 1054 Btuh Central vent (33 cfm) 727 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 25135 Btuh Use manufacturer's data n Rate/swing multiplier 1.00 Infiltration Equipment sensible load 28746 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction qualityAverage 1948 Btuh Fireplaces 1 (Average) Structure Ducts 2178 Btuh Heatin Coolin Central vent (33 cfm) 1196 Btuh Area (ft' 179 179 Equipment latent load 5322 Btuh Volume �ft3) 16146 16146 Air changes/hour 0.45 0.20 Equipment total load 34068 Btuh Equiv.AVF (cfm) 122 54 Req. total capacity at 0.70 SHR 3.4 ton Heating Equipment Summary Cooling Equipment Summary Make TEMPSTAR Make TEMPSTAR Trade Trade Model NXH542 Cond NXH542 ARI ref no. 6955283 Coil FXM4X42 ARI ref no. 6955283 15 SEER Efficiency 8.7 HSPF Efficiency 28778 Btuh Heating input Sensible cooling 12334 Btuh Heating output 40908 Btuh @ 47°F Latent cooling Btuh Temperature rise 27 'F Total cooling 41112 1112 cfm Actual air flow 1370 cfm Actual air flow 1370cfm/Btuh Air flow factor 0.057 cfm/Btuh Air flow factor sure 0 c H2O Static pressure 0 in H2O StatiLoadcse sible heat ratio 0.84 Space thermostat Printout certified by ACCA to meet all requirements of Manual J 8th Ed. +�F wviSl"ksoft Right-Suite®Universal 7.1.01 RSU05996 2014-Jul-24 11:01:14 ,4(--CA C:\Users\Sales\Documents\Wrightsoft HVAC\3.5TON Calc=MJ8 Orientation=N Page 1