Loading...
672 Ocean Blvd 2014 HJVAC CITY OF ATLANTIC BEACH J 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 �Wilt Application Number . . . . . 14-00001167 Date 7/22/14 Property Address . . . . . . 672 OCEAN BLVD Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . RES SF DISTRICT Application valuation . . . . 0 -------------------------------------------------------------- Application desc 1 CU 1 AHU -------------------------------------------------------------- Owner Contractor - ------------------------ ----------------------- TAYLOR, BROGAN B & NATALIE V DONOVAN HEATING & AIR 672 OCEAN BLVD. 315 SIXTH AVENUE SOUTH ATLANTIC BEACH FL 32233 JACKSONVILLE BEACH FL 32250 (904) 241-3785 --------------------------------------------------------- Permit MECHANICAL HVAC PERMIT Additional desc . . Permit Fee 99 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 1/18/15 ----------------------------------------------------- Special Notes and Comments STICKER FOR OVERCURRENT PROTECTION MUST BE ON A/C EQUIPMENT PRIOR TO INSPECTION. FAILURE TO COMPLY WILL RESULT IN A FAILED INSPECTION AND REINSPECT FEES . NO EXCEPTIONS . ----------------------------- Other Fees . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 -------------------------------------------------- Fee summary Charged Paid Credited - --Due--- ----------------- ---------- ---------- ---- Permit Fee Total 99 . 00 99 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 103 . 00 103 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax (904) 247-5845 fOB ADDRESS' -woc 0" bIJ PERMIT# PROJECT VALUE $ '45(05D ARI# _7v,SS - REQUIRED Air Handling Equipment Only _XAir Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating REQUIRED Duct Systems: Total CFM REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity 1 Tons Per Unit 3 1-2 Heat: Unit Quantity 1 BTU's Per Unit ed Seer Rating REQUIRED Duct Systems: Total CFM FIRE PREVENTION 3 sets of plans) Fire Sprinkler System Quantity (Requires p ) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read Tis application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority rttoo-violate t provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name Phone Number S7/ 19 q 9 Mechanical Company eG A) Office Phone Z yl 3-7f.YFax,)-Y/37yf� Co. Address: � S City�.4X -9 ol- State Zip3a License Holder(Print): �Q J State Certification/Registration# Notarized Signature of License Holder A j E.�"°v- RICHARD TOMPKINS Before me this day of ! 201-1-- Commission#FF 040399 n n �`�i o= Expires July 29,2017 Signature of Notary Public K 1 d� .�PIBanded Thru Troy Fain Ina�ranee 80038&7019 wri9htsoft Project SummaJob: Summary Date: July 21,2014 Enure House By: Aaron Thacker Donovan Heat&Air 315 6th Ave S,Jacksonville Beach, FL 32250 Phone:904-241-3785 Fax:904-241-3745 Email:aaron@donovanac.com Web:www.DonovanAC.com Project • • For: Tom Perry 672 Ocean Blvd,Atlatnic Beach, FL 32233 Notes: Design Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 T Outside db 95 °F Inside db 70 °F Inside db 75 °F Design TD 31 °F Design TD 20 °F Daily range L Relative humidity 50 % Moisture difference 53 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 26705 Btuh Structure 20836 Btuh Ducts 4286 Btuh Ducts 4188 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 30990 Btuh Use manufacturer's data n Rate/swing multiplier 1.00 Infiltration Equipment sensible load 25024 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1154 Btuh Ducts 1764 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area (ft') 1040 1040 Equipment latent load 2919 Btuh Volume (ft) 8320 8320 Air changesthour 0.45 0.23 Equipment total load 27943 Btuh Equiv.AVF (cfm) 62 32 Req. total capacity at 0.70 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Lennox Trade 13HPX SERIES Trade 13HPX SERIES Model 13HPX-036 Cond 13HPX-036 AHRI ref no5725542 Coil CBX25UH-036 AHRI ref no5725542 Efficiency 8.2 HSPF Efficiency 11.5 EER, 13.5 SEER Heating input Sensible cooling 20020 Btuh Heating output 27800 Btuh @ 47°F Latent cooling 8580 Btuh Temperature rise 27 °F Total cooling 28600 Btuh Actual air flow 953 cfm Actual air flow 953 cfm Air flow factor 0.031 cfm/Btuh Air flow factor 0.038 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.90 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. w r ig htsoft 2014-Jul-2113:11:38 Right-Suite®Universal 8 0 24 RSU05995 Page 1 C:\Users\Owner\Documents\Wrightsoft HVAC\Bogus 3 ton.rup Calc=MJ8 Front Door faces S