Loading...
583 Selva Lakes Cir 2014 HVAC CITY OF ATLANTIC H N C BEA C 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 Application Number . . . . . 14-00001274 Date 8/11/14 Property Address . . . . . . 583 SELVA LAKES CIR Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . TO BE UPDATED Application valuation . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ CLINE, CHRIS DONOVAN HEATING & AIR 1765 SELVA MARINA DR 315 SIXTH AVENUE SOUTH ATLANTIC BEACH FL 32233 JACKSONVILLE BEACH FL 32250 (904) 241-3785 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 95 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 2/07/15 ---------------------------------------------------------------------------- Special Notes and Comments STICKER FOR OVERCURRENT PROTECTION MUST BE ON A/C EQUIPMENT PRIOR TO INSPECTION. FAILURE TO COMPLY WILL RESULT IN A FAILED INSPECTION AND REINSPECT FEES . NO EXCEPTIONS . ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 95 . 00 95 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 99 . 00 99 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 fOB ADDRESS: 583 &I-IVg 1O -S C,{ _PERMIT# PROJECT VALUE $ Jbs2- 00 ARI# '/01 -7340 REQUIRED Air Handling Equipment Only X Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating REQUIRED Duct Systems: Total CFM REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit 1,5 13 Heat: Unit Quantity 1 BTU's Per Unit 30 oolf Seer RatingREQUIRED Duct Systems: Total CFM FIRE PREVENTION 3 sets of laps Fire Sprinkler System Quantity (Requires p ) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps erator Condenser BTU's #Vented Wall Furnaces RefriSol Collection Systems #Water Heaters Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read its application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name C�,,,S ,�,y�e Phone Number 509- oyy8 Mechanical Company ©np,, p� \ He,Ar Office Phone 2N137t f- Fax PY I D- r 31 S' (� Ave- s City Tiax '' �` In State Zip32 Ft' Co. Address: n License Holder(Print): At tam n �A� State Certification/Registration# CnCo3 Al Notarized Signature of License Holder nn L RICHARD TOMPKINS Before me this day of V S� 20 Commission#FF 040399 Expires duly 29,2017 �o Signature of Notary Public • ; �° ewa.d nni rmr Fain InwanaG wrightsoft- Project Summary Date: 818/14 Entire House By: Brandon Zahade Donovan Heat&Air ` 315 6th ave south,Jacksonville Beach,FL 32250 Phone:241-3785 Email:brandonedonovanac.com Project • • For: Cline 583 Selva lakes cir, Atlantic Beach, FL 32233 Notes: Design Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 OF Outside db 95 OF Inside db 68 OF Inside db 75 OF Design TD 29 OF Design TD 20 OF Daily range L Relative humidity 50 % Moisture difference 53 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 14414 Btuh Structure 14371 Btuh Ducts 3195 Btuh Ducts 4674 Btuh Central vent (13 cfm) 409 Btuh Central vent(13 cfm) 282 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 18019 Btuh Use manufacturer's data n Ratelswing multiplier 1.00 Infiltration Equipment sensible load 19327 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average 1921 Btuh Fireplaces 1 (Average) Structure Ducts 1006 Btuh Heating Cooling Central vent (13 cfm) 465 Btuh Area(ft1 1218 1218 Equipment latent load 3392 Btuh Volume?ft-) 10962 10962 Air chatuh es/hour 0.56 0.23 Equipment total load 22718 on Equiv.AVF (cfm) 102 42 Req. total capacity at 0.70 SHR 2.3 ton ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model 25HCD330 Cond 25HCD330 ARI ref no. 7017340 Coil FB4CNF030 ARI ref no. 7017340 13 EER Efficiency 7.7 HSPF Efficiency Heating Input Sensible cooling 20906 Btuh Heating output 29717 Btuh @ 47°F Latent cooling 8960 Btuh Temperature rise 34 OF Total cooling 29866 Btuh Actual air flow 801 cfm Actual air flow 801 cfm Air flow factor 0.045 cfm/Btuh Air flow factor 0.042 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.85 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. C -PFF wrightsoft- Right-Suite®Universal 7.1.01 RSU05996 2014Aug 08 1Page 4 AM C:\Users\Sales\Documents\Wrightsoft HVAC\2.5 TON Calc=MJ8 Orientation=N Page 1