Loading...
333 8Th St 2014 HVAC P CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 Application Number . . . . . 14-00001362 Date 8/21/14 Property Address . . . . . . 333 8TH ST Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . RES SF DISTRICT Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu 3 . 5 tons ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ COSTELLO GRACE C DONOVAN HEATING & AIR 333 8TH STREET 315 SIXTH AVENUE SOUTH ATLANTIC BEACH FL 32233 JACKSONVILLE BEACH FL 32250 (904) 241-3785 ---------------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 103 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 2/17/15 ---------------------------------------------------------------------------- Special Notes and Comments STICKER FOR OVERCURRENT PROTECTION MUST BE ON A/C EQUIPMENT PRIOR TO INSPECTION. FAILURE TO COMPLY WILL RESULT IN A FAILED INSPECTION AND REINSPECT FEES . NO EXCEPTIONS. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 -------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 103 . 00 103 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 107 . 00 107 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. c MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 10B ADDRESS: 333 0 L) Et PERMIT# PROJECT VALUE $ 4306 ARI# 69 S 36 Z3 REQUIRED Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity I Tons Per Unit3,s Heat: Unit Quantity 1 BTU's Per Unit //1.6-" Seer Rating 1 Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read its application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name ry o n. C s fj n Phone Number EY-7 -S(I Mechanical Company I )m»v&v } k / Office Phone -n n Co. Address: &� A� S City ��f ac.� State Zip 6 License Holder(Print): N .a State Certification/Registration# 39-76 Notarized Signature of License Holder RICHARD TOMPKINS Before me this _day of 4 v 20�_ Commission#FF 040399 = Expires July 29,2017 Baled TMu Twr fain lnwra c 9ONV5.7019 Signature of Notary Public i Job: wr htSoft' Project Summary Date: 81=14 Entire House By: Brandon Zaharie Donovan Heat& Air 315 6th ave south,Jacksonville Beach,FL 32250 Phone:241-3785 Email:brandonGdonovanac.com Project • • For: costello 333 8th st,Atlantic Beach, FL 32233 Notes: Design Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 OF Outside db 95 OF Inside db 68 OF Inside db 75 20 °F Design TD 29 OF Design TD L Daily range Relative humidity 50 % Moisture difference 53 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 17933 Btuh Structure 15831 Btuh Ducts 6147 Btuh Ducts 12188 Btuh Central vent (33 cfm) 1054 Btuh Central vent(33 cfm) 727 Btuh Humidification 0 Btuh Blower 0 Btuh 0 Btuh Equipment load 25135 Btuh Use manufacturer's data n Ratelswingg multipplier 1.00 Infiltration EquipmenfSens ible load 28746 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average 1948 Btuh Fireplaces 1 (Average) Structure Ducts 2178 Btuh 1196 Btuh Heatin coolin Central vent (33 cfm) 5322 Btuh Area(ft2 179 179 Equipment latent load Volume�ft') 16146 16146 34068 Btuh Air Changes/hour 0.45 0.20 Equipment total load Req. total capacity at 0.70 SHR 3.4 ton Equiv.AVF (cfm) 122 54 Heating Equipment Summary Cooling Equipment Summary Make Tempstar Make Tempstar Trade Trade Model N41-1342 Cond N41-1342 ARI ref no. 6953623 Coil FEM4P42 ARI ref no. 6953623 13 SEER Efficiency 8 HSPF Efficiency 28778 Btuh Heating Input Sensible cooling 12334 Btuh Heatingoutput 40908 Btuh @ 47°F Latent cooling 41112 Btuh Tempeature rise 27° F Total cooling 1370 1112cfm Actual air flow 1370 cfm Actual air flow 0.049 cfm/Btuh Air flow factor 0.057 cfm/Btuh Air flow factor 0 in H2O Static pressure 0 in H2O Load sensible heat ratio 0.84 Space thermostat Printout certified by ACCA to meet all requirements of Manual J 8th Ed. 2014-Aug-20 15:33:41 A f'I.F wriytstsoTt' Right-Suite®Universal 7.1.01 RSU05996 Page 1 AM C:\Users\Sales\Documents\Wrightsoft HVAC\3.5TON Calc=MJ8 Orientation=N ft w.