Loading...
379 1st St 2014 HVAC CITY OF ATLANTIC BEACH J 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Jjilt Application Number . . . . . 14-00001382 Date 8/25/14 Property Address . . . . . . 379 1ST ST Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . RES SF DISTRICT Application valuation . . . . 0 ------------------------------------------------------------------------ Application desc 1 cu 1 ahu 3tons ------------------------------------------------------------------------ Owner Contractor - ------------------------ ----------------------- LYLE, JEFFREY M & ELIZABETH DONOVAN HEATING & AIR PSC80 BOX 10546 315 SIXTH AVENUE SOUTH APO AP 96367 JACKSONVILLE BEACH FL 32250 (904) 241-3785 -------------------------------------------------------------------- Permit . . . . . . MECHANICAL HVAC PERMIT Additional desc . . Permit Fee 99 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 2/21/15 ------------------------------------------------------------ Special Notes and Comments STICKER FOR OVERCURRENT PROTECTION MUST BE ON A/C EQUIPMENT PRIOR TO INSPECTION. FAILURE TO COMPLY WILL RESULT IN A FAILED INSPECTION AND REINSPECT FEES . NO EXCEPTIONS . --------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 99 . 00 99 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 103 . 00 103 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 (OB ADDRESS: Sk f:5r PERMIT# PROJECT VALUE $ 41 Q° ARI# REQUIRED Air Handling Equipment Only _C Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating REQUIRED Duct Systems: Total CFM REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Seer Rating (3 Heat: Unit Quantity�— BTU's Per Unit gREQUIRED Duct Systems: Total CFM FIRE PREVENTION 3 sets of laps Fire Sprinkler System Quantity (Requires p ) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read tis application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.n. Property Owners Name Phone Number 3 I Y d p Mechanical Company i1'� "' �P t F\ Office Phone 37 5 Fax �y�3�`� Co. Address: r- ��� S City J�x State Zip3iZj�b 3���� License Holder(Print): v. J �`a o, °� ^j .State C ification/Registration# C4 co -1 Notarized Signature of License Holder _ nn RICHARD TOMPKINS Before me this 9� day of V 20 �1 := tic Commission#FF 040399 °• Signature of Notary Pub Expires July 29,2017 �'% AF o?•� B ded Th.troy Fein Imm gp0.3857019 Job: +�+ wrightsoft Project Summary Date: August 25,2014 Entire House By: Aaron Thacker Donovan Heat&Air 315 6th Ave S,Jacksonville Beach, FL 32250 Phone:904-241-3785 Fax:904-241-3745 Email:aaron@donovanac.com Web:www.DonavanAC.com Proiect Information For: Victoria Lyie 379 1st St,Atlantic Beach, FL 32233 Notes: Design Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 95 °F Inside db 70 °F Inside db 75 °F Design TD 31 °F Design TD 20 °F Daily range L Relative humidity 50 Moisture difference 53 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 26705 Btuh Structure 20836 Btuh Ducts 4737 Btuh Ducts 4619 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuhn Equipment load 31442 Btuh Use manufacturer's data 1.00 Rate/swing multiplier Infiltration Equipment sensible load 25455 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average 0 Structure 1154 Btuh Fireplaces Ducts 1970 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft') 1040 1040 Equipment latent load 3124 Btuh Volume (W) 8320 8320 28579 Btuh Air changes/hour 0.45 0.23 Equipment total load Equiv.AVF (cfm) 62 32 Req. total capacity at 0.70 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade BASE 13 PURON HP Trade BASE 13 PURON HP Model 25HBC336(A,W)"30 Cond 25HBC336(A,W)"30 AHRI ref no3699488 Coil FB4CNF036 AHRI ref no3699488 Efficiency 8 HSPF Efficiency 11.0 EER, 13 SEER S2EER Btuh Heating input Sensible cooling 10200 Btuh Heating output 34000 Btuh @ 47'F Latent cooling 34000 Btuh Temperature rise 27 °F Total cooling cfm Actual air flow 1133 cfm Actual air flow 110.033 33 cfm/Btuh Air flow factor 0.036 cfm/Btuh Air flow factor 0 c H2O Static pressure 0 in H2O Static pressure 0 89 Space thermostat Load sensible heat ratio Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2014-Aug-25 08:45:02 wrightsoft Right-Suite®Universal 8.0.24 RSU05995 Page 1 ACCO C\Users\Owner\DOCUments\Wrightsoft HVAC\Bogus 3 ton.rup Calc=MJ8 Front Door faces: W