1 Fleet landing (Coleman Cntr) 2014 fire supp CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD j ATLANTIC BEACH, FL 32233 FIRE SUPPRESSION SYSTRWECTION PHONE LINE 247-5814 r 'J ii CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 90B jNFORMATZ-10-Ni Job ID: 14-00000546 Job Type: MECHANICAL FIRE PERMIT Description: fire suppression Estimated Value: $3,800.00 Issue Date: 9/18/2014 Expiration Date: 3/17/2015 PROPERTY ADDRESS: Address: 1 FLEET LANDING BLVD RE Number: 169397-0200 PROPERTY OWNER: Name: CARE, NAVAL CONTINUING Address: PERMIT INFORMATION: 2010 FLORIDA BUILDING CODE, FLORIDA FIRE PREVENTION CODE 2008 NATIONAL ELECTRIC CODE BUILDING DEPARTMENT: FEES: State Mech DBPR Surcharge $2.00 State Mech DCA Surcharge $2.00 Trade Permit Base Fee $55.00 Total Payments: $0.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. K{ : FILE Cf WC FIRE SAFETY INC. 4-8-14 WC FIRE SAFETY INC. 17415 71"ST. SUITE A MONTVERDE, FLORIDA 407-469-3473 CONTACT.JUSTIN EARLY COLEMAN CTR. 1 FLEET LANDING BLVD. ATLANTIC BEACH, FLORIDA 32233 PLANS TO INSTALL A PRE-PIPED ANSUL FIRE SYSTEM USING A 3 GALLON CYLINDER CAPABLE OF 11 FLOW POINTS OF WHICH 11 WILL BE USED. THE TV- BANK PLENUM WILL BE PROTECTED WITH TWO 1N NOZZLES AND THE EXHAUST DUCT 10X20 WILL BE PROTECTED WITH TWO 2W NOZZLES. THE APPLIANCE PROTECTION WILL BE IN THE DRAWING. THE FIRE SYSTEM WILL SHUT OFF THE GAS, ELECTRIC AND SUPPLY FAN WHILE THE EXHAUST FAN WILL REMAIN ON OR TURN ON IF OFF.THE FIRE SYSTEM WILL RING AN AUDIBLE BELL. THE REMOTE PULL STATION WILL BE 10-20 FEET FROM THE HOOD TOWARDS THE EXIT AND THERE WILL BE 3 FUSIBLE LINKS USED. THE FIRE SYSTEM WILL CONFORM TO ALL LOCAL, STATE AND NFPA CODES. THE INSTALLATION WILL BE DONE WITH ALL 3/8" BLACK IRON PIPE. THE FIRE SYSTEM WILL BE UL 300 STANDARD. REVEMP FOR CODE COMPLUN(7, aC TI(OF ATLANTIC BEACH lw PMMM F0k ADD ANA1- C?UXRWENn AND CONDMONS. 0 P 6 p p x w x La o t- H N OJ p Q J Za W p D V1 W r N in Qx r. z UN O "a: Z Z >-r WM t.Wr Y W A q p a W0 m Ni.i r > U 5 ILD za¢ x w (L-i Qwr .:s Qi :Dm rQIO r o L '6S p2li WN M � i`ir W Q.WO Vly J C 3N .. oo Li N 11.J.S 2' ) a, Z J¢ Z U NW Niv�J 0- = L X 3 Ql7 0 Z „ry o W U r ZQ JJQQ M� 3 E a� C �W Mme-; Gc'�InvaoOma;@ ¢ Pa- >- a:X: qJ W 3 pp vv ^OW MMMMMiTMMMM YYWW~ ZZ JrU Wp, V) 0 ci a NN rr Mp OM,0 as 0T 0i 0 O,0�0� ,Z,�->> c3 Dg C3 awQ¢ vri¢ - U a' ° d �J�Zz �Q xrnia��d ���:�:�� JJaa� OWLS N� (71 "z NJ x O) rXQD 4- WWWQaQNoMaQ r--'JJJJJJJJJJY��fA V1aK Qr4.� .Z-.OWE �� U '6 c zz<mY -QQ�,�-..:�U yvMWCO Cl p7 R1(xi�POMUNNQQJO aw N N X W C I O X 3 Q Q W Z Z U p p O O O J Y p w w w w w w w w w w w x x �a N3WIU3W� W Zp W d JJ. O rrJF<¢OOvvvvZ UJVINVIN(nV1vl(AV1V10gWi` -i-i d J O x LD w J p o� W Q N to(n N(n V)(n Vl to to fA 0- X: WMNW WUWZ fW H i' ZONA 0ZzmM ZZWJJ0000IL-HZ N¢¢QQQQQ¢QQKdf UUfQ C]G]m[] O S(moi"- QJONW'-'J- q= y Nd Qoyd _j_j «+�-+WJWZWWWWWWWWWWrWrZ�WJ W Wzw iUQ- r �D� Nd Q a E J JJJJO_'4'R' J J JJJJJJJJJJU�"' a1-rW a wQ n(�a WF ui �p ii N^yam p�pQQOO7rrrrRlr WF NNNNNNNNNNW OULJZ Z,m Jr ZO N- N r171.7 L7 Vl Vl m m 22 J N J U NN N N NNN NNNr3 pUWf' a-Q¢p�a0 QZ l` MEP?�f/1"'-�" � U?(,.)QMwm<<000U=h--pnzzzzZZZZZZAJ2 xwo2o JW UXXXQO -JW .N-� C £7C 7C N W W J J X Z U d N U Z C N i >> ww-AdQQ�+WQ d.r S 3:-P 0 iZU IrioiOtiioo rt�tn�(nES. ssdin0No Q <mO DID L ZuzVMNOIDMOI-00v O O L>O_O Z 1 I 1 1 1 1 1 I 7�C]Nxmx cu(1) fnlDrl MOO,O,^ MNNNNNNNMf WM A;rylxoud 45H S try japojcPD43 ;uolp92i sod N I 8 & J1 a4L i arr �d mei N - a1ppl-,J Y �O IIUC't O � n lo N Ia R a xowx 1 ,w',2 ,Ig 0.1 N R;Mxwd 4 m poli-a6uv27 o J a1 o unuaid +aid � � SECTION IV — SYSTEM DESIGN UL EX3470 ULC EX3470 Page 4-1 7-1-09 REV.8 SYSTEM DESIGN GENERAL INFORMATION The ANSUL R-102 Restaurant Fire Suppression System may be 1. Nozzles must be located 2-8 in.(5-20 cm)into the center of the used on a number of different types of restaurant cooking appli- duct opening, discharging up.See Figure 1. ances and hood and duct configurations.The design information listed in this section deals with the limitations and parameters of this pre-engineered system.Those individuals responsible for the design of the R-102 system must be trained and hold a current ANSUL certificate in an R-102 training program. The R-102 and the PIRANHA systems use compatible agents and components, therefore, they may be used together for cooking appliance, hood, and duct protection. The primary ANSUL AUTOMAN Release can be either an R-102 or a PIRANHA ANSUL AUTOMAN Release and can actuate up to two additional R-102 or PIRANHA Regulated Actuators. In systems utilizing a 101 remote release, any combination of the maximum number of regulated actuators can be used. 2-8 IN. IS-20 cm) 1 • Both systems must actuate simultaneously. T • Each system must be designed and installed per its appropri- FIGURE 1 ate manual. 0001n • Adjacent appliances requiring protection must be protected 2.In installations where a UL listed damper assembly is with the same type of system, either R-102 or PIRANHA, employed, the duct nozzle can be installed beyond the 8 in. unless the center-to-center spacing between the adjacent (20 cm) maximum, to a point just beyond the damper assem- R-102 and PIRANHA nozzles is no less than 36 in.(91.4 cm). bly that will not interfere with the damper.Exceeding the maxi- When appliances are protected with R-102 nozzles, the hood mum of 8 in. (20 cm) in this way will not void the UL listing of and connecting duct above those appliances cannot be pro- the system. tected with PIRANHA nozzles. 3. Previously listed 3 flow number and 5 flow number duct pro- Mixing systems in a common plenum is not allowed. tection detailed in earlier published manual, Part No.418087- One of the key elements for restaurant fire protection is a correct 06, can also still by utilized. system design.This section is divided into ten sub-sections:Noz- DUCT SIZES UP TO 50 IN.(127 cm) zle Placement Requirements,Tank Quantity Requirements, Actu- ation and Expellant Gas Line Requirements, Distribution Piping Requirements, Detection System Requirements, Manual Pull Sta- One 1W nozzle(Part No.419336) =one flow number tion Requirements, Mechanical Gas Valve Requirements, Electri- 50 in.(127 cm) perimeter maximum cal Gas Valve Requirements, Electrical Switch Requirements, and Pressure Switch Requirements. Each of these sections must be 16 in. (41 cm)diameter maximum completed before attempting any installation. System design sketches should be made of all aspects of design for reference DUCT SIZES UP TO 100 IN.(254 cm) during installation. PERIMETER/32 IN. (81.3 cm) DIAMETER NOZZLE PLACEMENT REQUIREMENTS • One 2W Nozzle (Part No.419337)=two flow numbers This section gives guidelines for nozzle type, positioning, and 100 in.(254 cm) perimeter maximum quantity for duct,plenum,and individual appliance protection.This . 32 in. (81.3 cm)diameter maximum section must be completed before determining tank quantity and piping requirements. The chart below shows the maximum protection available from each duct nozzle. Duct Protection—Single Nozzle Part 3.0 Gallon 1.5 Gallon All duct protection is UL listed without limitation of maximum duct Description No. System System length (unlimited length).This includes all varieties of ductworks both horizontal and vertical including ducts that run at angles to 2W Nozzle 419337 Maximum Maximum the horizontal and ducts with directional bends. 100 in.(254 cm) 100 in.(254 cm) The R-102 system uses different duct nozzles depending on the Perimeter Perimeter size of duct being protected. 1 W Nozzle 419336 Maximum Maximum 50 in. (127 cm) 50 in.(127 cm) Perimeter Perimeter SECTION IV — SYSTEM DESIGN UL EX3470 ULC EX3470 Page 4-5 7-1-09 REV.5 Plenum Protection The R-102 system uses the 1W Nozzle (Part No.419336) or the 1 N Nozzle (Part No.419335)for plenum protection.The 1 W noz- zle ti p p annozzp p Is stam ed with 1 W d the 1 N le ti Is stam ed with 20 IN. U cm) MAXIMUM 1 N, indicating they are one-flow nozzles and must be counted as one flow number each. When protecting a plenum chamber, the entire chamber must be protected regardless of filter length. i IN.(2.5 cm) VERTICAL PROTECTION—GENERAL MINIMUM ' 1W NOZZLE — PART NO. 419336 — SINGLE AND"V" BANK 'PROTECTION 20 IN.(51 cm) One 1W nozzle will protect 4 linear feet (1.2 m) of plenum.The MAXIMUM maximum distance from the end of the hood to the first and last nozzle must be no more than 2 ft(0.6 m).After the first nozzle,any t additional nozzles must be positioned at a maximum of 4 ft(1.2 m) 1 IN.(2.5 cm) apart down the entire length of the plenum.The plenum width must LMINIMUM not exceed 4 ft(1.2 m).(The 1 W nozzle can be used on single or V-bank filter arrangements.) See Figure 6. FIGURE 7 000,99 2FT(0.6m) MAXIMUM Option 2:The 1 W nozzle must be placed perpendicular, 8-12 in. MAXIMUM) R (20-30 cm)from the face of the filter and angled to the 4 FT(1.2 m) \4 FT(12 m) center of the filter.The nozzle tip must be within 2 in. MAXIMUM MAXIMUM 2 FT(0.6 m) (5 cm) from the perpendicular center line of the filter. MAXIMUM See Figure 8. 12 IN.(30 cm) MAXIMUM 4 IN. (10 cm) 8 IN.(20 cm) MINIMUM NOZZLE TIP MUST BE WITHIN FIGURE 6 THIS AREA W0197 When protecting plenums with the 1 W nozzle,two options of cov- erage are available: FIGURE 8 00= Option 1:The 1 W nozzle must be on the center line of the single or "V" bank filter and positioned within 1-20 in. HORIZONTAL PROTECTION—OPTION 1 (2.5-51 cm) above the top edge of the filter. See 1 N NOZZLE—PART NO.419335—SINGLE BANK PROTECTION Figure 7. One 1 N nozzle will protect 10 linear feet(3.1 m)of single filter bank plenum.The nozzle(s) must be mounted in the plenum, 2 to 4 in. (5 to 10 cm) from the face of the filter, centered between the filter height dimension, and aimed down the length.The nozzle must be positioned 0-6 in.(0-15 cm)from the end of the hood to the tip of the nozzle.See Figure 9. 2—4 IN. 10 FT.(3.1 m) (5—10 cm) MAXIMUM 000201 000202 FIGURE 9 SECTION IV — SYSTEM DESIGN UL EX3470 ULC EX3470 Page 4-24 REV.7 7-1-09 ►Upright Broiler Protection Gas-Radiant/Electric Char-Broiler Protection The R-102 system uses two 1/2N Nozzles(Part No.419334)for all The R-102 system uses the 1 N nozzle, (Part No.419335)for gas- upright broiler protection.The nozzle tip is stamped 1/2N, indicat- radiant/electric char-broiler protection. ing that this is a half-flow nozzle.A pair of these nozzles will equal The nozzle tip on the 1 N nozzle is stamped with a 1 N, indicating one flow number. that this is a one-flow nozzle and must be counted as one flow Two 1/2N nozzles will protect a maximum hazard area (internal number. ►broiler chamber)of 30 in.x 32.5 in.(76 cm x 82.5 cm).These noz- One IN nozzle will protect a hazard with a maximum length of zles must always be used in pairs on an upright broiler.One noz- 36 in. (91 cm) and a total cooking area which does not exceed zle must be positioned above the grate and pointed at the back ►864 in.2 (5574 cm2). The nozzle tip must be located 15 to opposite corner of the broiler chamber.The second nozzle must 40 in. (38 to 102 cm) above the hazard surface.When using this ►be pointed down into the center of the drip pan through the open nozzle for gas-radiant/electric char-broiler protection, the nozzle ►slot.See Figure 58. must be positioned anywhere along or within the perimeter of the UPRIGHT BROILER maximum cooking area and shall be aimed at the center of the BROILER CHAMBER ►cooking surface. See Figure 59. COOKING AREA COOKING AREA 00025fi DRIP I PAN 1 40 IN. I I (102 cm) ^\ FRONT VIEW SIDE VIEW I i 1 MAXIMUM 15 IN. 38 cm i I MINIMUM j ( I 000252 FIGURE 58 000257 ' FIGURE 59 SECTION IV — SYSTEM DESIGN UL EX3470 ULC EX3470 Page 4-14 REV.6 7-1-09 ►Range Protection 245(2-Flow)Nozzle—High Proximity Application COOIN No Obstructions AREA AREA G —y ►40 in.to 50 in.(102 cm to 127 cm) above the cooking surface. This high proximity application uses the 245 nozzle, Part No. 419340. The nozzle tip is stamped with 245 indicating this is a two-flow COOKING nozzle and must be counted as two flow numbers. 245 NOZZLE TIP AREA LOCATION CENTER OF ►One 245 nozzle will protect a maximum cooking area of 672 in.2 COOKING SURFACE OR ►(4335 cm2)with a maximum longest dimension of 28 in.(71 cm). 11 are IN.(29 cm) MAXIMUM FROM When using this nozzle for range protection, the nozzle must CENTERLINE OF NOZZLE be pointed vertically down and positioned as shown in Figures TO CENTER OF ANY 29 and 30. BURNER GRATE 245 NOZZLE TIP LOCATION COOKING CENTERLINE OF COOKING SURFACE AREA -71 I � 245 NOZZLE TIP ( �. COOKING D G 7 1 (1 7 LOCATION CENTER OF AREA(127 cm) COOKING SURFACE I MAXIMUM OR HEIGHT 11 3/8 IN.(29 cm) OF 245 MAXIMUM FROM ' NOZZLE CENTERLINE OF NOZZLE ( TIP TO CENTER OF ANY 000766 ( BURNER GRATE ._ 1 140 IN. (102 cm) MINIMUM FIGURE 30 HEIGHT OF 245 NOZZLE TIP I I 000236 ffo_��__o O FIGURE 29 NOTICE Four burner grates shown in Figure 30. For sin- gle or double burner grates, locate nozzle at center of cooking surface or 11 3/8 in. (29 cm) maximum from nozzle centerline to center of any burner grate. SECTION IV — SYSTEM DESIGN UL EX3470 ULC EX3470 Page 4-19 7-1-09 REV.4 ►Griddle Protection 260(2-Flow) Nozzle—High Proximity ►Griddle Protection 290(2-Flow)Nozzle—Medium Proximity ►Application Application Option 2—Nozzle Perimeter Located Option 2a—Nozzle Perimeter Located (Continued) ►30 in.to 50 in.(76 cm to 127 cm) above the cooking surface. 20 in.to 30 in. (51 cm to 76 cm) above the cooking surface. This high proximity application uses the 260 nozzle, Part No. The medium proximity application uses the 290 nozzle, Part No. 419341. 419342. The nozzle tip is stamped with 260 indicating this is a two-flow The nozzle tip is stamped with 290 indicating this is a two-flow nozzle and must be counted as two flow numbers. nozzle and must be counted as two flow numbers. ►One 260 nozzle will protect a maximum cooking area of 1440 in? One 290 nozzle will protect a maximum cooking area of 1440 in.2 ►(9290 cm2)with a maximum dimension of 48 in.(122 cm). (9290 cm2)with a maximum dimension of 48 in.(122 cm). When using this nozzle for griddle protection, the nozzle must be When using this nozzle for griddle protection, the nozzle must positioned along the cooking surface perimeter to 2 in. be positioned along the perimeter to 2 in. (5.1 cm) inside (5.1 cm) inside perimeter, and aimed at the center of the cooking perimeter, and aimed at the center of the cooking surface. See Ii-surface.See Figure 43 and 44. Figure 45 and 46. I I NOZZLE LOCATION COOKING AREA 0—2 IN.(0—5 cm) I I t INSIDE PERIMETER I 50 IN. -►� 4- OF COOKING SURFACE i I M27IMU)M I I HEIGHT r f CENTER OF I OF 260 COOKING SURFACE I I I NOZZLE TIP I / 1 1 I I MINIMUM cm) I J-�� /! I AREEAKING EDGE I I j l HEIGHT I / OF—�I I �/ I I OF 260 AIM POINT 1 l COOKING I I i ) NOZZLE TIP L___..___—__ I J SURFACE OW243 290 NOZZLE LOCATED ALONG COOKING SURFACE EDGE ANY SIDE OF GRIDDLE SURFACE WITHIN 0—2 IN.(0—5 cm)OF COOKING SURFACE EDGE.NOZZLE MUST BE AIMED AT CENTER OF FIGURE 43 COOKING SURFACE. 000243 FIGURE 45 COOKING AREA oou<, I NOZZLE LOCATION i 0—2 IN.(0—5 cm) I MIDPOINT OF I I INSIDE PERIMETER I 30 IN. COOKING SURFACE f —+� LQ— OF COOKING SURFACE I I (76 cm I II I I MAXIMUM InROnING j OFi2 0T I AIM POINT i I I 1 1 NOZZLE TIP 20 IN.(51 cm) I 1 I I MINIMUM —j I I HEIGHT I I I I OF 290 l I NOZZLE TIP II I � 260 NOZZLE LOCATED ALONG COOKING SURFACE EDGE ANY SIDE OF GRIDDLE SURFACE WITHIN 0—2 IN.(0—5 cm)OF EDGE OF COOKING SURFACE EDGE.NOZZLE COOKING MUST BE AIMED AT MIDPOINT OF SURFACE ► COOKING SURFACE. FIGURE 44 000241 FIGURE 46 ► 000243 SECTION III—SYSTEM COMPONENTS UL EX3470 ULC EX3470 Page 3-1 7-1-09 REV.6 EXTINGUISHING AGENT ANSULEX Low pH Liquid Fire Suppressant(1.5 gallon—Part No. "ANSUL AUTOMAN"REGULATED RELEASE ASSEMBLY 79694 or 3.0 gallon—Part No.79372) is a potassium-based solu- (MECHANICAL) tion designed for fast knock-down and suppression of grease- related fres.The agent is shipped in plastic containers which pro- NOTE:AGENT TANK MUST BE vide one complete tank charge.(Refer to Section V, Page 5-2.1,for ORDERED SEPARATELY maximum agent fill capacity.) Agent storage life expectancy is OR SEE PAGE 3-4 o twelve years and can be stored at a temperature of--40 OF to 130 RELEASE ► OF(-40°C to 54°C).Note:When installing agent in R-102 sys- MECHANISM ►tem, temperature range is 32 OF (0 0C) to 130 OF (54 0C). The distributor must record the batch numbers and date of shipment receipt to be filed with each installation record. s 'ANSULEX'LOW pH LIQUID FIRE SUPPRESSANT 1 U� REGULATOR SHIPPING WT.25 LB(11 kg) FIGURE 2 3.0 GALLON 1.5 GALLON 000138 SHIPPING WT.35 LB(16 kg) SHIPPING WT.19 LB(9 kg) 000136 000137 REGULATED RELEASE ASSEMBLY(ELECTRICAL) FIGURE 1 The ANSUL AUTOMAN Regulated Electrical Release Assembly REGULATED RELEASE ASSEMBLY(MECHANICAL) (Part No. 429856) is identical to the mechanical version except it also contains a factory installed 120 VAC solenoid and electrical The ANSUL AUTOMAN Regulated Mechanical Release Assembly switch. (Part No. 429853) contains the regulated release mechanism, The solenoid is used to provide electrical actuation of the release expellant gas hose for agent tank hookup, and enclosure knock- mechanism.The electric switch is used to protect the solenoid by outs to facilitate installing actuation piping;expellant piping;detec- opening the circuit to the solenoid once the system is fired. tion System; and additional equipment. This regulated release Additional electrical switches can be added as required for auto- assembly is used in single,double,and multiple-tank systems and matic equipment and gas shut-off accessories,as well as initiating must be mounted to a rigid surface.The release mechanism can audible and visual alarms. be used to interconnect both the actuation and expellant gas lines as required per system design.The regulator is designed to allow "ANSUL AUTOMAN"REGULATED RELEASE ASSEMBLY ►a constant flow of gas into the tank at 110 psi (7.6 bar)when the (ELECTRICAL)' system is actuated.The agent tank must be ordered separately. In single, double, and multiple-tank systems, the provided expel- NOTE:AGENT TANK MUST BE ORDERED a lant gas hose connects the agent tank to the bottom outlet of the SEPARATELY regulator. In double and multiple-tank system configurations, the OR SEE PAGE 3-4 back outlet of the regulator is used as an expellant gas feed for one additional tank-enclosure or tank-bracket hookup.The enclo- REGULATOR sure contains the required knockouts to facilitate this connection. swrcH If a pressure switch is to be attached to the regulator,additional fit- tings are required. The tank is mounted within the enclosure.The tank contains an SOLENOID adaptorttube assembly with a burst disc union. The burst disc helps prevent siphoning of the agent up the pipe due to significant temperature fluctuations in the area where the tank is located.The ►tank is stainless steel and, under normal conditions, requires hydrostatic testing every twelve years. The detection and additional equipment required per system design are connected to the release mechanism.The enclosure SHIPPING WT.34 LB(15 kg) contains knockouts to facilitate detection and additional hookups. The system can be actuated automatically or manually.Automatic actuation occurs when a fusible link within the detection system FIGURE 3 separates in a fire condition. Manual actuation of the system 000133 occurs when personnel pull on the remote manual pull station •NOTE:ANSUL AUTOMAN Regulated Electrical Release,Part No.429856,is not pull ring. intended to be used with electric detection. SECTION III—SYSTEM COMPONENTS UL EX3470 ULC EX3470 Page 3-5 7-1-09 REV.8 GAS CARTRIDGES NOZZLES The R-102 system uses gas cartridges to store nitrogen or carbon There are 11 types of discharge nozzles each designed to distrib- dioxide expellant gases under pressure until the system is actuat- ute the liquid agent in a uniform pattern throughout the hazard ed, at which time the cartridge seal is punctured and the released area: gas expels liquid agent from one or more tanks through the dis- 1. 1 W Nozzle 7. 245 Nozzle charge piping and out the discharge nozzles. 2. 1 N Nozzle 8. 260 Nozzle Four nitrogen gas cartridges and three carbon dioxide gas car- 3. 1/2N Nozzle 9. 290 Nozzle tridges are available as shown in Figure 13. 4. 3N Nozzle 10. 2120 Nozzle Cartridges noted as TC/DOT are both Transport Canada(TC)and S. 2W Nozzle 11. IF Nozzle Department of Transportation (DOT) approved. Cartridges noted 6. 230 Nozzle as DOT are Department of Transportation approved only. Cartridge selection options are provided in Section IV under Tank Although these nozzles are similar in appearance and have and Cartridge Requirements. certain common parts, the tip of each nozzle is designed for a specific application and must only be used in those areas. See NITROGEN GAS CARTRIDGES Nozzle Application Chart in Section IV — System Design, for individual nozzle usage. 3B-18 NPT FEMALETHREAD 1 17 1/4 IN. ► 11 5/8 IN. 12 1/4 IN. (43-8 cm) INTERNAL CUP 7 7/8 IN. (29.5 cm) (20 cm) (31.1 cm) STRAINER ► INSIDE RECESS FOR -= BLOW OFF y��//yyyy ��// 21/2 IN. 2 1/2 IN. 4 3116 IN. 3 9/16 IN. CAP LOOP XAM-A VENDOR (6.4 cm) (6.4 an) (10.6 cm) (9 cm) CODE LT-20-R LT-30-R DOUBLE-TANK LT-A-101-30 NOZZLE (IF PRESENT) CARTRIDGE CARTRIDGE CARTRIDGE CARTRIDGE STAMPING ► M0145 000146 000W 000148 CARBON DIOXIDE CARTRIDGES FIGURE Nozzle Identification Chart ►Note:See Component Index for nozzle package shipping assem- bly part numbers. 11 5/6 w. Nozzle 9 IN. 7 7/8 IN. (29.5 an) Nozzle Nozzle Nozzle' Flow (22.9 cm) (20 cm) ►Type Part No, Stamping No. Nozzle Material ► 1W Nozzle 419336 1 W" 1 Chrome-Plated Body /�{.--.II ► 1N Nozzle 419335 1 N" 1 Chrome-Plated Body 2IN. 21/2 IN. 21/21N. 1/2N Nozzle 419334 1/2N 1/2 Chrome-Plated Body (5.1 cm) (6.4 cm) (6-4 cm) ►3N Nozzle 419338 3N 3 Chrome-Plated Body 101-10 CARTRIDGE 101-20 CARTRIDGE 101-30 CARTRIDGE ► W0149 am15� p 151 2W Nozzle 419337 2W 2 Chrome-Plated Body FIGURE 13 230 Nozzle 419339 230 2 Chrome-Plated Body Additional cartridge shipping assemblies are available for 245 Nozzle 419340 245 2 Chrome-Plated Body European and Australian requirements. 260 Nozzle 419341 260 2 Chrome-Plated Body ►Cartridge European Australian TC/DOT 290 Nozzle 419342 290 2 Chrome-Plated Body Description Part No. Part No. Part No. 2120 Nozzle 419343 2120 2 Chrome-Plated Body LT20-R 428440 428948 423429 1 F Nozzle 419333 1F 1 Chrome-Plated Body LT-30-R 428441 426553 423435 `Nozzle stamping may contain an additional letter indicating a vendor's code. Double Tank 428446 426563 423493 ►—Stainless steel versions are available in the 1W nozzle(Part No.432527)and LT-A-101-30 428442 426555 423491 ► the 1 N nozzle(Part No.435672). 101-10—CO2 428443 N/A 423439 SILICONE LUBRICANT 101-20—CO2 428445 N/A 423441 Dow Corning Compound 111, Part No. 78112, is available in a 101-30—CO2 428444 N/A 423443 5.3-ounce tube.Compound has excellent qualities for sealing and P.Note: For 101-10 cartridge, Part No. 15850 is DOT only. lubricating system components. SECTION III—SYSTEM COMPONENTS UL EX3470 ULC EX3470 Page 3-8 REV 8 7-1-09 DETECTORS PULLEY TEE The detector consists of three basic components:the bracket,link- The Pulley Tee (Part No.427929) is used to change the direction age, and fusible link. (Fusible links are not included and must be of two wire ropes by 900.It must be used in areas where the tem- ordered separately.)The bracket holds the entire assembly to the peratures are within the range of 32°F to 130 °F(0 °C to 54 °C). mounting surface.The linkage is used to support the fusible link. Pulley tees can be used in mechanical gas valve actuation lines The fusible link is designed to separate at a specific temperature and remote manual pull station lines. Pulley tees cannot be used and release the wire rope,thereby actuating the regulated release within a detection line. mechanism. ►The scissor style detector allows the wire rope to be strung com- pletely through the detection system conduit and brackets first and B O the detector linkage assemblies are then clipped on later. ►The detector consists of two types of assemblies: ►The Terminal Detector(Part No.435546)includes a test link and is placed last in a series of detectors.This detector is sometimes ► FIGURE 26 referred to as the end-of-line detector and is thus named because 000^7 it is at the point at which the wire rope"terminates,"or is anchored at the detector bracket.Only one terminal detector is required per STAINLESS STEEL CABLE detection system. The 1/16 in.stainless steel cable is run from the terminal detector, ►The Series Detector(Part No.435547)is any detector located in- through conduit, all series detectors and pulley elbows, and into line between the regulated release assembly and the terminal the regulated release mechanism trip lever.When any fusible link detector. separates, the tension on the cable is relaxed, and the trip lever ►When using Part No.435546 and 435547 detectors, a total of 15 actuates the regulated release mechanism.The cable can also be detectors can be in one detection system:14 series detectors,Part used for mechanical gas valves and remote manual pull stations. ►No.435547 and 1 terminal detector, Part No.435546. The cable is available in 50 ft (15 m) (Part No. 15821) and 500 ft (152.4 m) (Part No.79653) lengths. ►Note:Series Detector, Part No.435547, is also available as Part ►No.435548,25/Pkg. ► _ SCISSOR STYLE-PART NO.435546 AND 435547 BRACKET LINKAGE a FUSIBLE v LINK ► FIGURE 24 W0159 PULLEY ELBOWS There are two types of pulley elbows used to change the direction of the wire rope by 90°.ANSUL recommends for temperatures not in excess of 700 °F (371 °C). Part No. 415670 has socket ends with set screws for 1/2 in.conduit, and Part No.423250 has com- pression ring ends also for 1/2 in.conduit. Pulley elbows must be ordered in quantities of 50 as Shipping Assembly Part No.415671 (socket end type) and Part No.423251 (compression end type). PART NO.415670 PART NO.423250 O 000160 OD0161 ' FIGURE 25 SECTION III-SYSTEM COMPONENTS UL EX3470 ULC EX3470 Page 3-9 7-1-09 REV.5 REMOTE MANUAL PULL STATION MECHANICAL GAS VALVES The remote manual pull station (Part No. 434618 or 435960) is The mechanical gas valves are designed to shut off the flow of gas made out of a molded red composite material. The red color to the appliances upon actuation of the regulated release assem- makes the pull station more readily identifiable as the manual bly.The valves are available in sizes of 3/4 in., 1 in., 1 1/4 in., 1 1/2 means for fire suppression system operation.The pull station is in., and 2 in.ANSUL style;and 2 1/2 in.and 3 in.ASCO style.The compatible with the ANSUL Flexible Conduit.The molded manual valves are rated for natural and LP gas.Both styles are UL Listed pull station should be mounted at a point of egress and positioned 'and includes the air cylinder, tubing, and fittings, Part No. 15733, at a height determined by the authority having jurisdiction. Trim for connection to the release mechanism. Rings, Part No.427074 (pack of 10), are available. Maximum Part No.434618(Without Wire Rope) Part Operating Part No.435960(With 50 ft(15.2 m)of Wire Rope) No. Description Pressure 0 55598 3/4 in.Gas Valve(ANSUL) 10 psi (0.69 bar) 55601 1 in.Gas Valve (ANSUL) 10 psi (0.69 bar) QQO� 55604 1 1/4 in.Gas Valve (ANSUL) 10 psi (0.69 bar) 55607 1 1/2 in.Gas Valve (ANSUL) 10 psi (0.69 bar) 55610 2 in.Gas Valve (ANSUL) 10 psi (0.69 bar) P(1JI� 25937 2 1/2 in.Gas Valve (ASCO) 5 psi (0.35 bar) 25938 3 in.Gas Valve(ASCO) 5 psi (0.35 bar) ' Flow Capacity BTU/HR, at 1 in.P.D. FIGURE 27 (CFH) 0.64 SP GR �26 Pipe Size P.D. 1 in.WC 1000 BTU/ft3 (inches) 0.64 SP GR Natural Gas FLEXIBLE CONDUIT 3/4 751 751,000 Flexible conduit allows for quicker installations and the conve- 1 1288 1,288,000 nience of being able to route the cable over, under and around 1 1/4 1718 1,718,000 obstacles. Flexible conduit can be used as a substitute for stan- 1 1/2 2630 2,630,000 dard EMT conduit or can be used with EMT conduit.Flexible con- 2 4616 4,616,000 duit can be used only with the Molded Manual Pull Station, Part 21/2 5700 5,800,000 No.434618, and mechanical gas valve installations.The Flexible 3 7100 7,300,000 Conduit comes in a 500 ft (152.4 m) length, Part No. 434525, or To calculate gas flow for other than 1 inch p.d.: together with 500 ft(152.4 m)of wire rope, Part No.435959. Also available is a Flexible Conduit Strain Relief (50-pack), Part New cfh=(cfh at 1 inch)x new p.-d. No.435979. To calculate gas flow for other than 0.64 SP GR: A 50-pack of Flexible Conduit Inserts, Part No. 434347, is also New cfh = (cfh at 0.64)x 0.6 available. New SP GR ►Note:Flexible conduit cannot be used in detection systems. A B C Valve Size in. (mm) in. (mm) in. (mm) 3/4 in. 33/4 (95.3) 63/8 (161.9) 51/2 (139.7) 1 in. 33/4 (95.3) 63/8 (161.9) 51/2 (139.7) 1 1/4 in. 47/8 (123.8) 73/8 (187.3) 63/8 (161.9) 1 112 in. 47/8 (123.8) 73/8 (187.3) 63/8 (161.9) 2 in. 57/8 (149.2) 77/8 (200.0) 611/16 (169.9) 2 1/2 in. 713/16 (198.4) ----- 91/16 (230.2) 3 in. 725/32 (197.6) ----- 91/16 (230.2) ► c c �I JI + 3/4 IN.THRU 2 IN. 2 1/2 IN.THRU 3 IN. 004208 004209 ' FIGURE 28 ul co I o ui*",—t -T 46 0 cl) Lr) > CL) C=) Z> < 6—CL R 0 uj > ly LU Lij -jLZ >- LIJ V,w ,x yui [- d F- Li LL x LL oz > tL < WP- 0 Min Li Z LL LL, I rk lwu Co y cy- C) CD 6j Ul :ad -C: < LIJ Zr) LJ 6) M-0 -J LU I m :r U 0 ZO< cri z gn Z, 0 w Vim Xo D- LL -i t '4 kv u Z- t�M ': , Ed: iL Li Uj 0 Qa- 4: zz 0 0 zo ><--�, j'z u UJQL LWD MMM 0 o 6-Lup 0 0 'y Z Z u -j-i JJ 7 1J u Q W,ow >1 L,g:z O-j x m '-j >RL Wh 0 EC3 zap 0 z< < L) IT ec"IT T 1,12 TQ T MX TO T v on IS 6 aw -0"WX C3, W w ;;> x I o 3: 'c W,w w ri La L,La W W La 60,UVI ll� L :7) (,:3,w a-LJ z, uj L-3 w �'44 "011wo )m F- 0- ni J L.) ' QQdQ Jzoouo A 0 ox 0 Z, W w -iw z WWWWWWW W,,L,0- Lj� 'N N'LJ =U0> ows:=IMM�, DL� 0 0 0 0 0 D�w(M Q� n u... U LLJ X ZZ Fu WZZ<-<<OWOnMOOmoaOOOOW -W-jw -6 -EM 0 .LEMR. 0FWQVI 1 -J d E::* W�qW_ _j =ZjW LZ -j <<YL,U 0-N d 4'-0 0,0 C ZW In C��CD C) > C13 L*j aJ2 mol 0 0-0 C�. <P�j WM zi WX CU-----MWWMWWNNMXWMW W'el j� a 00W00'UT A:�MN.Oldrn 45H 10 w - aippi-ID A4mo.,d 461H paw-aeu" wrpAaw wwaw L cooL IL 6 � L 831Nr)OD GOOH ,L pooy ,Z ao� 11X3 uoljejs lInd =IV! wPoop! ,L ao# 1=ST QOOH ,Z n; " F uoljels Ilnd L—L-- j NVld 210013 I sui11W anoge amen seS 'y:)aW „Z 9170000-Z6C1331 L170000-Z6G33 L £Lt'£-6917-LOt 3NOHd 99L17C 13 3(183A-LNOW ##133H5 S#3AI23a 3aIS3>1d3 £0691 o31AN SV SNOI1d3:)X3 ❑ ONI,l133yS 32f13 OM SNOI1d3JX3 ON ❑ 3DVU3AO:)31ZZON ON N3nO>101a8 C13SOID nid uoiIuanaad 8113 8111AU �Ia� cl7mgl -311 )INVi inSNa NOIIV!D S'T - a3Sn S1NIOd M013 S 30 Z AnN3ld XNV --- 319NIS,Z - iDno ,LX„9 j m-. XNII3181Sn3 V.._..._...._._........_...___: V01YOU `H3V39 JIINV'71V 'GA79 9NKINV'71337j t "?113 NV'14/370J 9H1lb 9Nl©NV'71997-4 "3NI- A13.4 V-130" 381d 3M �Z/ z Graham, Shirley From: Graham, Shirley Sent: Wednesday, April 09, 2014 3:39 PM To: 'Ratliff, Bob' Cc: 'jwalker@coab.us'; Jones, Mike; Hubsch, Jeremy Subject: Fire Suppression for Coleman Cnter Fleet Landing (Dining room remodel) Bob,We have some plans that need your review. sKrl.eU Graham Building Permits Technician 800 Seminole Rd Atlantic Beach, Fl 32233 904 247 5800 saraham@coab.us i Graham, Shirley From: Graham, Sh, ley Sent: Wednes&, May 21, 2014 11:23 AM To: 'Ratliff, Bo Subject: RE: Fire S_.,_pression for Coleman Cnter Fleet Landing (Dining room remodel) Bob, Did you ever review this? sKrl.eo ctrakclm Building Permits Technician 800 Seminole Rd Atlantic Beach, Fl 32233 904 247 5800 syraham@coab.us From: Ratliff, Bob [mailto:BRatliff@coj.ngt] Sent: Wednesday, April 09, 2014 3:50 '''4 To: Graham, Shirley Cc: Walker, Jennifer; Jones, Mike; Hubsch, Jeremy Subject: RE: Fire Suppression for Coleman Cnter Fleet Landing (Dining room remodel) Thank you, Eric may stop by and pick them up for us. I am going to be out of the office until next Tuesday but will be checking my email each evening. Thanks, eapta& o4 RatW, UPS Jacksonville Fire & Rescue Department Fire Prevention Division Office of Plan Review 214 N. Hogan Street Room 281 Jacksonville, FL 32202 (904) 255-8320 Office (904) 255-8559 Fax CONFIDENTIALITY NOTICE: Please note that under Florida's very broad public n• ds law,e-mail communications to and from city officials are subject to public disclosure. From: Graham, Shirley [mailto:sgrahar -J�coab.us] Sent: Wednesday, April 09, 2014 3:39 A To: Ratliff, Bob Cc: Walker, Jennifer; Jones, Mike; Hubsch, Jeremy Subject: Fire Suppression for Coleman Cnter Fleet Landing (Dining room remodel) Bob,We have some plans that need your review. shLrLeo crahavu a. Building Permits Technician 800 Seminole Rd Atlantic Beach, F132233 904 247 5800 sgraham@coab.us 2 _ 1VIECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH C� FILE COPY 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904)247-5826 Fax(904) 247-5845 APR 09 2014 JOB ADDRESS: 1 Flee-A- LQQck�na �1vd PROJECT VALUE $ 63e - 00 ARI# REQUIRED Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: .ermit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read his application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or tot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name ne e4- IS Lrjin,-, 1e nnar\ Gerr4er— Phone Number qpq-a19- 4WZ, Mechanical Company etre. �,n A1C, , Office Phone 01- q-3qlPax q0l- 4(#9-o!)9j -o. Address: City lHDaw" State Zip Z*q sw- License Holder(Print): State Certification/Registration#FW a-(=0 4-- Votarized Signature of License Holder E ELISSA A WATSONB fore me this I day of I-kir-,r20 COMMISSION#FF032535y S afore of Notary Publik�,�EXPIRES Jul 1,2017Horidallotaryservice.com City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by he Building Department.) f 800 Seminole Road C — D�l/ r� Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 • Fax(904)247-5845 A �r 111S) E-mail: building-dept@coab.us Date routed: / City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM �� ed Ite,m a-n ern T5- Property Address: / f �G� Z&770/1fijp#pAdment review required Yes No Building Applicant: /�L �/� Planning &Zoning Tree Administrator Project: kPublic Works Public Utilities Publi fet Fire Services Other Agency Review or Permit Required Review or Receipt Date of Permit Verified B Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. E36enied. (Circle one.) Comments: k s c,,- - BUILDING Ir ' ' -✓ PLANNING &ZONING Reviewed by: 411,uf Date: TREE ADMIN. Second Review: �pproved as revised. ❑Denied. l PUBLIC WORKS Comments: ����v,a�,_, �r Srl�-.r-^'> o �L7 �J`•� ('-'� PUBLIC UTILITIES 4'4'� PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: []Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09 MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH g (� 0 00 Seminole Rd Atlantic Beach,FL 32233 Ph(904)247-5826 Fax(904)247-5845 APR 092014 TOB ADDRESS: 0 F 1�e�r d in a1vd # PROJECT VALUE $ 5`300 . 00 ARI# REQUIRED _Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only JEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED tEPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED 1" PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) [RE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's LL OTHER GAS PIPING Elevators/Escalators Heat Exchanger Quantity of Outlets #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks (gallons) Wells CHER: nit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. ,perry Owners Name Ppp4— `Q rnan Gem Phone Number a19- 4ppZ chanical Company �, �►re. S01 � � Office Phone 441-4W-3q'7Pax yoj_ 4(v9-.9)@j Address: CitY.Ho6WcLQ State Zip M q S u ense Holder(Print): �v, 1�;r� _ t State Certification/Registration#g' ta.-(�ppp 4-+ arized Signature of License Holder .:�o��""A� MELISSA A WA7SON __ B fore me this I day of r-r 20 � *€ My COMMISSION#FF032535 TFo�, EXPIRES July 1,2017 Siafore of Notary Publikkxu" (407)396.0153 FloridallotaryService.com Stag; City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by he Building Department.) ) 800 Seminole Road Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 - Fax(904) 247-5845 9 E-mail: building-dept@coab.us Date routed: City web-site: http://www.coab.us �Wo�n n APPLICATION REVIEW AND TRACKING FORM &11d1j1n ,z-n01 Property Address: / f �G� !/ y>n 6 Ad ment review re uired Yes No p Y Building ��£ Planning &Zoning Applicant: Tree Administrator Project: Public Works Public Utilities Publ fet Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Dateof Permit Verified B Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: [Approved. ❑Denied. (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: Date: TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. []Denied. Comments: Reviewed by: Date: Revised 05/14/09 Graham, Shirley From: Padgett, He dy [HPadgett@coj.net] Sent: Wednesda May 21, 2014 3:30 PM To: Ratliff, Bok;. graham, Shirley Cc: Johnson, C. Earles Subject: RE: Fire Suppression for Coleman Cnter Fleet Landing (Dining room remodel) That was the suppression permit. I sent it back unapproved. Information lacking. I talked to the individual that applied for the permit a while back. He was to send more information. I never heard back from him. Hardy From: Ratliff, Bob Sent: Wednesday, May 21, 2014 1:13 M To: 'Graham, Shirley' Cc: Padgett, Hardy; Johnson, Charles Subject: RE: Fire Suppression for Coler,.an Cnter Fleet Landing (Dining room remodel) Shirley, I do remember looking at the Building -nd Sprinkler plans for this project I also know that the hood suppression system plans were returned for corrections ai am not aware of the corrections being made if that is the plan you are speaking of. Hardy might be able to help out with more info also. eapatin J'34 lea 1W, CFPS Jacksonville Fire & Rescue Department Fire Prevention Division Office of Plan Review 214 N. Hogan Street Room 281 Jacksonville, FL 32202 (904) 255-8320 Office (904) 255-8559 Fax CONFIDENTIALITY NOTICE: Please note that under Florida's very broad public reg rds law,e-mail communications to and from city officials are subject to public disclosure. From: Graham, Shirley [mailto:sgraha' i)coab.us] Sent: Wednesday, May 21, 2014 12:3- 'M To: Ratliff, Bob Subject: FW: Fire Suppression for Coleman Cnter Fleet Landing (Dining room remodel) Bob, I think Charles is looking at a different fire suppression plan...this one Eric Pardee picked up on 4/10 for you, our permit# 14-546. Shirley From: Johnson, Charles [mailto:Johns coj.net] Sent: Wednesday, May 21, 2014 12:30 :'M To: Graham, Shirley I