Loading...
365 8TH ST 2014 NEW HOME ICC EVALUATION c SERVICE ICC-ES Report ICC-ES 1 (800) 42 . • 699-0543 • • 1 to 03/16 i did DIVISION:07 00 00—THERMAL AND MOISTURE PROTECTION SECTION:07 2100—THERMAL INSULATION REPORT HOLDER: DEMILEC USA LLC 3315 EAST DIVISION STREET ARLINGTON,TEXAS 76011 EVALUATION SUBJECT: DEM ILEC APXTM SPRAY-APPLIED POLYURETHANE FOAM INSULATION C ICC ICC ICC C C� PING LISTED Look for the trusted marks of Conformity! "2014 Recipient of Prestigious Western States Seismic Policy Council : (WSSPC)Award in Excellence" A Subsidiary of coDic Nair SCC A-,.&M l ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not cars specifically addressed nor are they to be construed as an endorsement of the subject of the report or a t GD recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. 70M ncc.e�en�i tcN G_G rum Copyright© 2015 G`GV O�` cICC EVALUATION c SERVICE Widely Accepted and Trusted IM - IMES Evaluation Report ESR-3470 Reissued March 2015 This report is subject to renewal March 2016. www.icc-es.org 1 (800)423-6587 1 (562)699-0543 A Subsidiary of the Intemational Code Council® DIVISION: 07 00 00—Thermal and Moisture Protection component of floor/ceiling and wall assemblies. The Section:07 21 00—Thermal Insulation insulation is a two-component spray foam plastic with a nominal in-place density of 0.5 pcf (8 kg/m3). The REPORT HOLDER: insulation is produced in the field by combining a polymeric isocyanate (A-PMDITI" component) with a polymeric resin DEMILEC USA LLC (APXTm B-Side Resin). The insulation liquid components 3315 EAST DIVISION STREET are supplied in 55-gallon (208 L) drums and/or 250-gallon ARLINGTON,TEXAS 76011 (946 L)totes.The A-PMDITM component must be stored at (817)640-4900 temperatures between 50°F (10°C) and 100°F (38°C) and www.DemilecUSA.com has a shelf life of one year when stored in factory-sealed lnfo(a)DemilecUSA.com containers at these temperatures. The APXTm B-Side EVALUATION SUBJECT: Resin must be stored at temperatures between 50°F (10aC)and 100 F (38 C)and has a shelf life of six months when stored in factory-sealed containers at these DEMILEC APXTm SPRAY-APPLIED POLYURETHANE FOAM INSULATION temperatures. 3.2 Surface-burning Characteristics: 1.0 EVALUATION SCOPE The insulation, at a maximum thickness of 4 inches Compliance with the following codes: (102 mm)and a nominal density of 0.5 pcf(8 kg/m3), has a flame-spread index of 25 or less and a smoke-developed ■ 2012 and 2009 International Building Code®(IBC) index of 450 or less when tested in accordance with ASTM ■ 2012 and 2009 International Residential Code®(IRC) E84. Greater thicknesses are recognized as described in ■ 2012 and 2009 International Energy Conservation Sections 4.3 and 4.4. The thickness of Demilec APXTm Code®(IECC) foam is not limited when the insulation is separated from the interior of the building by a prescriptive thermal barrier IN 2013 Abu Dhabi Intemationa/Building Code(ADIBC)t such as 1/2-inch-thick(12.7 mm)gypsum board. tThe ADIBC is based on the 2009 IBC.2009 IBC code sections referenced 3.3 Thermal Resistance,R-values: in this report are the same sections in the ADIBC. ■ Other Codes(see Section 8.0) The insulation has thermal resistance (R-value) at a mean Properties evaluated: temperature of 75°F(24°C)as shown in Table 1. 3.4 Air Permeability: ■ Surface-burning characteristics spray-applied Demilec APXT"^ ■ Physical properties polyurethane foam insulation, at a minimum thickness of 31/2 inches (89 mm), ■ Thermal resistance is considered air-impermeable insulation in accordance ■ Attic and crawl space installation with 2012 IRC Section R806.5 or 2009 IRC Section R806.4, based on testing in accordance with ASTM E283 ■ Air permeability and ASTM E2178. 2.0 USES 3.5 BlazelokTm TBX Intumescent Coating: Demilec APXTm spray-applied polyurethane foam BlazelokTm TBX intumescent coating, manufactured by insulation is used as a nonstructural thermal insulating TPR2 Corporation, is a one-component, water-based liquid material in Type V-B construction under the IBC and in coating with specific gravity of 1.3. BlazelokTm TBX is dwellings under the IRC. The insulation is for use in wall supplied in 5-gallon (19 L) pails and 55-gallon (208 L) cavities, floor/ceiling assemblies, or attics and crawl drums and has a shelf life of one year when stored in spaces when installed in accordance with Section 4.0. factory-sealed containers at temperatures between 45°F Under the IRC, the insulation may be used as air- (7°C)and 90°F(32°C). impermeable insulation when installed in accordance with Section 3.4. 4.0 DESIGN AND INSTALLATION 3.0 DESCRIPTION 4.1 General: y 3.1 General: Demilec APXTm spray-applied foam insulati st be installed in accordance with the Center fo rethane Demilec APXTm spray-applied foam insulation is semi-rigid, Industries Guidance on Best Practices Installation low-density, polyurethane foam plastic installed as a of Spray Polyurethane Foam,the m rer's published !CC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed,nor are they be construed as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied as to any finding or other matter in this report,or as to any product covered by the report. Copyright O 2015 Pagel of 3 ESR-3470 I Most Widely Accepted and Trusted Page 2 of 3 technical data sheet and product application guide, and attics in accordance with 2012 IRC Section R806.5 or 2009 this report.A copy of each must be available at all times on IRC Section R806.4,as applicable. the jobsite during installation. 4.4.2 Application without a Prescriptive Ignition 4.2 Application: Barrier: Where Demilec APXTm spray-applied foam The Demilec APXTm insulation is spray-applied on the insulation is installed in accordance with this section and jobsite using a volumetric positive displacement pump as Section 4.4.2.2,the following conditions apply: identified in the Demilec application guide. The insulation a. Entry to the attic or crawl space is only to service must be applied when the ambient and substrate utilities,and no storage is permitted. temperatures are higher than 45°F (7.20C). The insulation b. There are no interconnected attic or crawl space areas. must not be used in areas that have a maximum in-service temperature higher than 180°F (820C). The foam plastic c. Air in the attic or crawl space is not circulated to other must not be used in electrical outlet or junction boxes or in parts of the building. contact with water, rain or soil. The foam plastic must not d. Under-floor (crawl space) ventilation is provided when be sprayed onto a substrate that is wet, or covered with required by IBC Section 1203.3 or IRC Section R408.1, frost or ice, loose scales, rust,oil,or grease.The insulation as applicable. must be protected from the weather during and after application.The insulation may be applied to the maximum e. Attic ventilation is provided when required by IBC thickness in a single pass. Where insulation is used as an Section 1203.2 or IRC Section R806, except when air- air-impermeable insulation, such as in unvented attic impermeable insulation is permitted in unvented attics assemblies under 2012 IRC Section R806.5 or 2009 IRC in accordance with 2012 IRC Section R806.5 or 2009 Section R806.4, the insulation must be installed at a Section R806.4 or Section 1203.2 of the IBC as minimum thickness of 31/2 inches(89 mm). applicable. 4.3 Thermal Barrier: f. Combustion air is provided in accordance with IMC (International Mechanical Code®)Section 701. 4.3.1 Application with a Prescriptive Thermal Barrier: 4.4.2.1 Attics and Crawl Spaces: In attics and crawl Demilec APXTm spray foam insulation must be separated spaces, the insulation may be spray-applied to the from the interior of the building by an approved thermal barrier of (12.7 mm) gypsum wallboard or an underside of the roof sheathing and/or rafters, to the underside of wood floors and to vertical surfaces as equivalent 15-minute thermal barrier complying with, and installed in accordance with, IBC Section 2603.4 or IRC described in this section. The thickness of the foam plastic applied to the underside of the top of the space must not Section R316.4, as applicable, except where insulation is in an attic or crawl space as described in Section 4.4. exceed 113/4 inches (298 mm), and the thickness when Demilec APXTm foam thickness is not limited when the applied to vertical surfaces must not exceed an inches insulation is separated from the interior of the building by (197 mm). The insulation does not require an ignition barrier or coating. an approved thermal barrier, based on fire testing in accordance with NFPA 286 and AC377. 4.4.2.2 Use on Attic Floors: The spray-applied foam 4.3.2 Application without a Thermal or Ignition insulation may be installed at a maximum thickness of Barrer: The prescriptive 15-minute thermal barrier or t /4 inches without mm) between and/or over floor joists in ignition barrier may be omitted when installation is in attic floors without an ignition barrier, coating or covering. accordance with this section. Demilec APXT"' spray foam Demilec APXTm spray foam insulation may m applied to a insulation and BlazelokTm TBX intumescent coating may be maximum thickness of 113/4 inches (298 mm) on the attic spray-applied to the interior facing of walls and the floor between and/or over the joists when a prescriptive underside of roof sheathing or roof rafters, and in crawl ignition barrier is installed in accordance with IBC Section spaces, and may be left exposed as an interior finish 2603.4.1.6 or IRC Section 316.5.3. The insulation must be without a prescribed 15-minute thermal barrier or ignition separated from the interior by an approved thermal barrier. barrier. The foam plastic insulation thickness must not 5.0 CONDITIONS OF USE exceed 71/2 inches (191 mm) in walls and 111/2 inches The Demilec APXTM spray foam insulation described in this (292 mm)in floors and ceilings. All foam surfaces must be report complies with, or is a suitable alternative to what is covered with an 11-mil dry thickness (0.28 mm) [17 mils specified in,those codes listed in Section 1.0 of this report, wet thickness (0.43 mm)] of BlazelokTm TBX intumescent subject to the following conditions: coating, described in Section 3.5.The intumescent coating must be spray-applied over the insulation in accordance 5.1 The products must be installed in accordance with the with the coating manufacturer's instructions and this report Center for Polyurethane Industries Guidance on Best at a rate of 85 square feet per gallon (2.09 m2/Q to obtain Practices for the Installation of Spray Polyurethane the recommended minimum dry film thickness noted in this Foam, the manufacturer's published technical data section. sheet and product application guide, this evaluation report and the applicable code. If there are any 4.4 Attics and Crawl Spaces: conflicts between other published guides and this 4.4.1 Application with a Prescriptive Ignition Barrier: report,this report governs. When Demilec APXTM spray foam insulation is installed 5.2 The insulation must be separated from the interior of within attics or crawl spaces where entry is made only for the building by an approved 15-minute thermal barrier service of utilities, an ignition barrier must be installed in as described in Section 4.3.1, except when accordance with IBC Section 2603.4.1.6 or IRC Section installation is in attics and crawl spaces as described A R316.5.3 or R316.5.4, as applicable. The ignition barrier in Section 4.4. O` must be consistent with the requirements for the type of 5.3 The insulation must not exceed the thicknesses}�otQ . , . , . . . I I construction required by the applicable code, and must be in Sections 32 42 43 and 44 installed in a manner so the foam plastic insulation is not `` exposed. Demilec APXTm spray-applied foam insulation as 5.4 The insulation must be protected fro sure to described in this section may be installed in unvented weather during and after application. O ESR-3470 I Most Widely Accepted and Trusted Page 3 of 3 5.5 The insulation must be applied by contractors 8.0 OTHER CODES authorized by Demilec USA LLC. In addition to the codes referenced in Section 1.0, the 5.6 Use of the insulation in areas where the probability of products recognized in this report have also been termite infestation is "very heavy" must be in evaluated in accordance with the following codes: accordance with IRC Section R318.4 or 2012 IBC ■ 2006 and 2003 International Building Code(IBC) Section 2603.9 or 2009 IBC Section 2603.8, as applicable. C)0 2006 and 2003 International Residential Code(IR 5.7 A vapor retarder must be installed in accordance with • 2006 and 2003 International Energy Conservation the applicable code. Code(IECC) 5.8 Jobsite certification and labeling of the insulation must The products comply with the above-mentioned codes as �7 comply with IRC Sections N1101.4 and N1101.4.1 or described in Sections 2.0 through 7.0 of this report except IECC Section R401.3,as applicable. as noted below: 5.9 The insulation is produced in Arlington, Texas, under • Application with a prescriptive thermal barrier: See a quality control program with inspections by ICC-ES. Section 4.3.1, except the approved thermal barrier must be installed in accordance with Section R314.4 of the 6.0 EVIDENCE SUBMITTED 2006 IRC or Section R314.1.12 of the 2003 IRC. 6.1 Data in accordance with the ICC-ES Acceptance • Application with a prescriptive ignition barrier:See Criteria for Spray-applied Foam Plastic Insulation Section 4.4.1, except attics must be vented in (AC377), dated November 2012, including reports of accordance with Section 1203.2 of the 2006 and 2003 tests in accordance with Appendix X of AC377. IBC or Section R806 of the 2003 IRC, and crawl space ventilation must be in accordance with IBC Section 6.2 Reports of air leakage testing in accordance with 1203.3 of the 2006 and 2003 IBC or IRC Section R408, ASTM E283. as applicable. Additionally, an ignition barrier must be 6.3 Reports of air permeance tests in accordance with installed in accordance with Section R314.5.3 or ASTM E2178. R314.5.3 of the 2006 IRC or Section R314.2.3 of the 6.4 Reports of room corner tests in accordance with 2003 IRC,as applicable. NFPA 286. ■ Application without a prescriptive ignition barrier: See Section 4.4.2, except attics must be vented in 7.0 IDENTIFICATION accordance with Section 1203.2 of the 2006 and 2003 Components of the spray foam insulation are identified IBC or Section R806 of the IRC, and crawl space with the manufacturer's name (Demilec USA LLC), ventilation must be in accordance with Section 1203.3 of address and telephone number; the product name the 2006 and 2003 IBC or Section R408 of the IRC, as (Demilec APXTm B-Side Resin or A-PMDITm); use applicable. instructions; the density; the flame-spread and smoke- ■ Protection against termites: See Section 5.6, except developed indices; the date of manufacture; thermal use of the insulation in areas where the probability of resistance values; the evaluation report number termite infestation is "very heavy" must be in (ESR-3470). accordance with Section R320.5 of the 2006 IRC or Each pail of the BlazelokTM' TBX intumescent coating is Section R320.4 of the 2003 IRC. labeled with the manufacturer's name (TPR2 Corporation), ■ Jobsite certification and labeling: See Section 5.9, the product name,and use instructions. except jobsite certification and labeling must comply with Sections 102.1.1 and 102.1.11, as applicable, of the 2006 IECC. TABLE 1-THERMAL RESISTANCE(R-VALUES) THICKNESS(inches) RWALUE(°F.ftZ.h/Btu) 1 3.7 3.5 12 4 14 5.5 19 7.5 26 8.75 30 11 38 14.25 49 For SI:1 inch=25.4 mm;1 °F.ft2.h/Btu=0.176 110`K,M2/W. R-values are calculated based on tested Kvalues at 1-and 4-inch thicknesses. O� �G O� DEMILEC • AFX 1 % DEMILEC TECHNICAL DATA Demilec APX®is a two component,open cell,spray applied,semi-rigid polyurethane foam system.This product is a fully water blown foam system with a low in-place density with excellent adhesion to various substrates and to itself.Demilec APX complies with the intent of the International Code Council's residential and commercial building codes for spray polyurethane foam plastic insulation.Demilec APX is compliant with AC-377 Appendix X and can be installed in attics and crawl spaces without an ignition barrier.Demilec APX is compliant with the VOC emissions standard of California Specification 01350.Demilec APX meets the USDA guidelines for incidental food contact. PROPERTIESPHYSICAL ASTM D 1622 Density 0.45-0.5 lb/ft' 7.2-8 kg/m3 ASTM C 518 Aged Thermal Resistance(R-value @ 1 inch) 3.7 ft2h°F/BTU 0.65 Km2/W ASTM E 283 Air Permeance @ 75 Pa @ 3.5" 0.003 L/sm2 Air Permeance @ 50 Pa @ 3.5" 0.002 L/sm2 ASTM E 2178 Air Permeance @ 100 Pa @ 3.5" 0.004 L/sm2 Air Permeance @ 300 Pa @ 3.5" 0.009 L/sm2 ASTM E 96 Water Vapor Permeance @ 3.5" 4.57 perms 261 ng/Pa•s•m2 Water Vapor Permeance @ 5.5" 2.90 perms 166 ng/Pa•s•m2 CA Spec 01350 VOC Emissions Standard Compliant ASTM D 1621 Compressive Strength 1.1 psi 7.6 kPa ASTM D 1623 Tensile Strength 3.7 psi 25.5 kPa FIRE TEST RESULTS Surface Burning Characteristics,4"thick Class I 7ASTM77 Flame Spread Index 15 Smoke Developed 350 Ignition Barrier-Compliant with 2006,2009&2012 IBC and IRC,and ICC-ES AC-377 NFPA 286 Appendix X,for use in attics and crawl spaces without a prescriptive ignition barrier,thermal Pass barrier or intumescent coating. NFPA 286 Thermal Barrier-Compliant with the 2006,2009&2012 IBC and IRC,as an interior finish Pass without a 15 minute thermal barrier with BLAZELOK-TBX at 11 mils dry film thickness. ASTM D 1929 Ignition Properties(spontaneous ignition temperature) 670°F(354°C) LIQUID COMPONENT PROPERTIES' PROPERTY A-PMDI ISOCYANATE DEMILEC APX RESIN Color Brown Amber Viscosity @ 77°F(25°C) 180-220 cps 150-250 cps Specific Gravity 1.24 1.15-1.20 Shelf Life of unopened drum properly stored 12 months 6 months Storage Temperature 50-100°F(10-38°C) 50-100°F(10-38°C) Mixing Ratio(volume) 1:1 1:1 'See SDS for more information. PROFILEREACTIVITY Cream Time Gel Time Tack Free Time End of Rise 1-2 seconds 3-5 seconds 6-7 seconds 6-7 second G� Gki 3315 E.Division Street,Arlington,TX 76011 milec APX Technical Data Sheet Phone(817)640-4900,Toll Free(877)336-4532 Last Revision-2-16-15 Fax(817)633-2000,Info@Demilec.com,www.Demilec.com Page 1 of 2 I?5.N4 11,1--'G A p X RECOMMENDED PROCESSING CONDITIONS' Initial Recirculating Setpoint Temperature 110°F 43°C Initial Primary Heater Setpoint Temperature 140°F 60°C Initial Hose Heat Setpoint Temperature 140°F 60°C Initial Processing Setpoint Temperature 1200 psi 8274 kPa Substrate&Ambient Temperature >45°F >7°C Moisture Content of Substrate 519% 519% `Foam application temperatures and pressures can vary widely depending on temperature,humidity,elevation,substrate,equipment and other factors.While processing,the applicator must continuously observe the characteristics of the sprayed foam and adjust processing temperatures and pressures to maintain proper cell structure,adhesion,cohesion and general foam quality.It is the sole responsibility of the applicator to process and apply Demilec APX within specification. General Requirements:Equipment must be capable of delivering the proper ratio(1:1 by volume)of polymeric isocyanate(PMDI)and polyol blend at adequate temperatures and spray pressures.Substrate must be at least 5 degrees above dew point,with best processing results when ambient humidity is below 80%.Substrate must also be free of moisture(dew or frost),grease,oil,solvents and other materials that would adversely affect adhesion of the polyurethane foam. Demilec APX must be separated from the interior of the building by an approved thermal barrier or an approved finish material equivalent to a thermal barrier in accordance with applicable codes.Demilec APX must be sprayed at a minimum thickness of 3"per pass.This product must not be used when the continuous service temperature of the substrate or foam is below-60°F(-51°C)or above 180°F(82°C).Demilec APX should not be used in contact with bulk water,below grade or to cover flexible ductwork. Disclaimer:The information herein is to assist customers in determining whether our products are suitable for their applications.We request that customers inspect and test our products before use and satisfy themselves as to contents and suitability.Nothing herein shall constitute a warranty,expressed or implied,including any warranty of merchantability or fitness,nor is protection from any law or patent inferred.All patent rights are reserved.The foam product is combustible and must be protected in accordance with applicable codes.Protect from direct flame and spark contact,around hot work for example.The exclusive remedy for all proven claims is replacement of our materials. G� 3315 E.Division Street,Arlington,TX 76011 Demilec APX Technical Data Sheet Last Revision 2-16-15 Phone(817)640-4900,Toll Free(877)336-4532 Fax(817)633-2000,Info@Demilec.com,www.Demilec.com Page 2 of 2