5807 Fleet Landing screen room 2014 CITY OF ATLANTIC BEACH j 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 � )J CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 IAR TNFARMATTAN- Job ID: 14-00001349 Job Type: RESIDENTIAL ADDITION Description: ENCLOSE PORCH Estimated Value: $6,000.00 PROPERTY ADDRESS: Address: 5807 FLEET LANDING BLVD RE Number: LOC ID-0000 PROPERTY OWNER: Name: CARE, NAVAL CONTINUING Address: GENERAL CONTRACTOR INFORMATION: Name: NCCRF Address: Phone- - - FEES: BUILDING PERMIT FEE $80.00 STATE DCA SURCHARGE $1.20 PLAN CHECK FEES $40.00 STATE DBPR SURCHARGE $1.20 Total Payments: $122.40 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. BUILDING PERMIT APPLICATION CITY OF ATLANTIC BEACH F I 800 Seminole Road, Atlantic Beach, FL 32233 Office (904) 247-5826 Fax (904) 247.5845 Job Address: ��r .� n w Pernut Number: Legal Description Parcel# Valuation of Work $ 4 j 000 Proposed Work hea ea/cooled t non-heated/cooled Class of Work(circle one): New Additio :51ter;ati) Repair Move Demolition pool/spa window/door Use of existing/proposed structures) (circle one): mmercial Residentia If an existing structure, is a fire sprinkler system installed? (Circle one): o N/A Florida Product Approval# For multiple products use product approva orm Describe in detail the type of work to be performed: Property Owner Information• Name:NCCRF dba Fleet Landiniz Address: 1 Fleet Landing Blvd City Atlantic Beach State FL_Zip 32233 Phone 904-246-9900 xt 431 E-Mail or Fax#(Optional)jholder@fleetlanding.com Contractor Information: Company Name:NCCRF dba Fleet Landing_Qualifying Agent: Jason Holder Address:I Fleet Landing Blvd City Atlantic Beach State FL Zip 32233 Office Phone 904-246-9900 xt 431 Job Site/Contact Number 904-219-4002 F State Certification/Registration#CBC 1254586 Architect Name&Phone# Engineer's Name&Phone# Fee Simple Title Holder Name and Address Bonding Company Name and Address Mortgage Lender Name and Address Application is hereby made to obtain a permit to do the xork and installations as indicated I certify that no larork or installation has commenced prior to the issuance of a permit and that all work will be pe�fornred to meet the sta�ada,ds of all laws regarlaliflg consb7,ction in thisiy isdiction. This permit becomes null �r1d void rf work is not commenced within six(6)months, or if constnrction or work is suspended or abatfda�ed for a penod ofsix(6)months at any time after work is commenced. 1 understand that separate permits must be secured for Electrical Work, Plu7nbiirg;Signs, Wells, Pools, Furnaces, Boilers,Heaters, Tanks and Air Conditioners,etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YO'UR NOTICE OF COMMENCEMENT. 'hereb certify that I have read and examined this a plication and know the same to be true and correct. illprovisions of laxs and ordinances governing this ype of xork will be complied with whether specs red herein or not. The granting of a permit does m , •esume to give authority to violate or cancel the 7rovrsrons of any other federal,state,or local law regal ling construction or the peifornlance of construe.; signature of Owner Signature of Contractor Tint Name Jason Holder Print Name Jason Hol r ......................................................... ................ . . ............................... ;worn to and subscribed before me Sworn to and subscribed before me his 1 l Day of. Arn`P_2/ 20 this _Day of 20 )j — &)M lotary Public V N..�.... 4►!...... SHARI R QUEST += MY COMMISSION#FF0Fi82a7 + +• Sr 1R1 R QUEST . 1 MY C�' MMISSION#FF 9941 d 1•26.10 EXPIRES November 4.2017 +E........•• `Of r �(pl� .S November 4.2017 o Via,. (407)3W0153 FloridallotatyService.com "" n ____ '1 • \M10/\�C1 C ^In A1.in n.Cnn.nn n m 71, F- 11 CHTF FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: FLEE121 Builder Name: Street 5807 N FLEET LANDING BLVD Permit Office: CITY OF ATLANTIC BEACH City, State,Zip: ATLANTIC BEACH , FL,32233- Permit Number: Owner: NAVAL CONTINUING CARE RETIREMENT FOUNDA Jurisdiction: 261100 Design Location: FL,Jacksonville 1. New construction or existing Addition 9. Wall Types(220.0 sqft.) Insulation Area a. Frame-Steel,Exterior R=19.0 220.00 ft2 2. Single family or multiple family Multi family b. N/A R= ft2 3. Number of units.if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms(Bedrms In Addition) 0(0) d. N/A R= ft2 10.Ceiling Types (121.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck(Unvented) R=19.0 121.00 ft2 6. Conditioned floor area above grade(ft2) 121 b.N/A R= ft2 c. N/A R= ft2 Conditioned floor area below grade(ft2) 0 11. Ducts R ft2 7. Windows(77.9 sqft.) Description Area a.Sup:Attic, Ret:Attic,AH:Garage 6 24.2 a. U-Factor: Dbl. U=0.30 66.25 ft2 SHGC: SHGC=0.16 b. U-Factor: Dbl, U=0.33 11.63 ft2 12.Cooling systems kBtu/hr Efficiency a.Geothermal Heat Pump 34.0 EER:15.20 SHGC: SHGC=0.30 c. U-Factor N/A ft2 SHGC: 13. Heating systems kBtu Efficiency 41 d. U-Factor: N/A ft a.Geothermal Heat Pump 41.5 COP:5.30 SHGC. Area Weighted Average Overhang Depth: 1.333 ft. Area Weighted Average SHGC: 0.181 14. Hot water systems-None required a Cap:N/A 8. Floor Types (121.0 sqft.) Insulation Area EF:5.74603E26 a. Slab-On-Grade Edge Insulation R=0.0 121.00 ft2 b. Conservation features b. N/A R= ft2 Heat Recovery Unit c. N/A R= ft2 15.Credits CF Total Proposed Modified Loads: 2.03 PASS Glass/Floor Area: 0.644 Total Standard Reference Loads: 5.16 I hereby certify that the plans and specifications covered by Review of the plans and 011iAE S-r4� this calculation are in compliance with the Florida Energy specifications covered by this w' ;y Code. ��7��,T �i calculation indicates compliance vj" rrff �' VY l NDN ANN WALKER with the Florida Energy Code. PREPARED BY: } -__ Before construction is completed 04 O DATE: _____ _ d� this building will be inspected for 0 s compliance with Section 553.908 # ° I hereby certify that this building, as designed, is in compliance Florida Statutes. , c.,'� with the Florida Energy Code. COQ OWNER/AGENT:_ - - - -- - BUILDING OFFICIAL: DATE: - _ DATE: -_- - - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist SEP 22 ?-014 9/20/2014 11:1D AM Ener - - "Aion 405.4.1 Compliant Software Page 1 of 5 I TABLE 402.4.2 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: FLEE121 Builder Name: Street. 5807 N FLEET LANDING BLVD Permit Office: CITY OF ATLANTIC BEACH City,State.Zip: ATLANTIC BEACH , FL.32233- Permit Number: Owner: NAVAL CONTINUING CARE RETIREMENT FOUNDA Jurisdiction: 261100 Design Location: FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier Exterior thermal envelope insulation for framed walls is installed in substantial contact and continuous alignment with building envelope air barrier. Breaks or joints in the air barrier are filled or repaired. Air-permeable insulation is not used as a sealing material. Air-permeable insulation is inside of an air barrier. Ceiling/attic Air barrier in any dropped ceiling/soffit is substantially aligned with insulation and any gaps are sealed. Attic access (except unvented attic), knee wall door, or drop down stair is sealed. Walls Corners and headers are insulated. Junction of foundation and sill plate is sealed. Windows and doors Space between window/doorjambs and framing is sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including Insulation is installed to maintain permanent contact with underside above-garage and of subfloor decking. cantilevered floors) Crawl space walls Insulation is permanently attached to walls. Exposed earth in unvented crawl spaces is covered with Class I Shafts, penetrations Duct shafts, utility penetrations, knee walls and flue shafts opening to exterior or unconditioned space are sealed. Narrow cavities Batts in narrow cavities are cut to fit, or narrow cavities are filled by sprayed/blown insulation. Garage separation Air sealing is provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures are air tight, IC rated, and sealed to drywall. Exception—fixtures in conditioned space. Plumbing and wiring Insulation is placed between outside and pipes. Batt insulation is cut to fit around wiring and plumbing, or sprayed/blown insulation Shower/tub on exterior wall Showers and tubs on exterior walls have insulation and an air barrier se arating them from the exterior wall. Electrical/phone box on Air barrier extends behind boxes or air sealed-type boxes are installed. Common wall Air barrier is installed in common wall between dwelling units. HVAC register boots HVAC register boots that penetrate building envelope are sealed to subfloor or drywall. Fireplace Fireplace walls include an air barrier. EnergyGaugeO USA-FlaRes2010 Section 405.4.1 Compliant Software PROJECT Title: FLEE121 Bedrooms: 0 Address Type: Street Address Building Type: User Conditioned Area: 121 Lot# Owner: NAVAL CONTINUING CARE Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 5807 N FLEET LANDIN Permit Office: CITY OF ATLANTIC BEACH Cross Ventilation: No County: Duval Jurisdiction: 261100 Whole House Fan: No City,State,Zip: ATLANTIC BEACH, Family Type: Multi-family FL, 32233- New/Existing: Addition Comment: HOUSE FRONT DOOR WEST ORIENTATION CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL—JACKSONVILLE—INT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Block1 121 968 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 ADDITION 121 968 No 0 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio ADDITION 22 ft 0 121 ft2 0.2 0.2 0.6 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Barrel tile 135 ft2 0 ft2 Light 0.65 No 0.9 No 19 26.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Unvented 0 121 ft2 N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic(Unvented) ADDITION 0.1 121 ft2 0.11 Wood 9/20/2014 11:10 AM EnergyGaugeO USA-FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below A Ornt To Wall Type R-Vahle Pt In Et In Area R--Value Fraction AhSor Gratip% 1 S Exterior Frame-Steel ADDITION 19 11 0 10 0 110.0 ft2 0 0.23 0.29 0 2 E Exterior Frame-Steel ADDITION 19 11 0 10 0 110.0 ft2 0 0.23 0.29 0 DOORS V # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Insulated ADDITION None .4 1 2.4 6 8 8 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. / Wall Overhang V/ # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 S 1 Vinyl Low-E Double Yes 0.33 0.3 11.6 ft2 1 ft 4 in 2 ft 5 in None None 2 S 1 Vinyl Low-E Double Yes 0.3 0.16 22.1 ft2 1 ft 4 in 1 ft 0 in None None 3 E 2 Vinyl Low-E Double Yes 0.3 0.16 22.1 ft2 1 ft 4 in 1 ft 0 in None None 4 E 2 Vinyl Low-E Double Yes 0.3 0.16 22.1 ft2 1 ft 4 in 1 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 528 ft2 528 ft2 53 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess .0003 95.2 5.23 9.83 .231 5.9018 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Geothermal Heat Pump Water Source-Closed Loop COP:5.3 41.5 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Geothermal Heat Pump Water Source-Closed Loop EER: 15.2 34 kBtu/hr 1020 cfm 0.74 1 sys#1 SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 9/20/2014 11:10 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5 DUCTS / —Supply--- —Return--- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 24.2 ftz Attic 6.05 ft2 Default Leakage Garage (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling [[X]]Jan [[X]]Feb jxj Mar [[X]A r X]Ma [[X]]Jun [ Jul [[X]]Au [[X]Se X]Oct [[ Nov [[X]Dec Heatin [X]Jan [X]Feb XMar [X]Ar IX]MaY [X]Jun [ Jul [X]Au [X]Sep EX]Oct [X Nov [X]Dec Venting [X Jan [X Feb X Mar [X Apr X May [X]]Jun X Jul [[XX]]Aug [[XX]]Se [X]Oct [[ Nov [[XX]]Dec Thermostat Schedule: BABM2008 Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 Cooling(WEH) AM 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 Heating(WD) AM 70 70 70 70 70 70 70 70 70 70 70 70 PM 70 70 70 70 70 70 70 70 70 70 70 70 Heating(WEH) AM 70 70 70 70 70 70 70 70 70 70 70 70 PM 70 70 70 70 70 70 70 70 70 70 70 70 9/20/2014 11:10 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5 f FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: 5807 N FLEET LANDING BLVD PERMIT#: ATLANTIC BEACH, FL, 32233- MANDATORY REQUIREMENTS SUMMARY-See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC-rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors&outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat& 403.1 At least one thermostat shall be provided for each separate heating controls and cooling system. Where forced-air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker j (electric)or shutoff(gas). Circulating system pipes insulated to= V/ R-2 +accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower(HP)of= 1 &Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor-retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site-recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP=4.0. Cooling/heating 403.6 Sizing calculation performed& attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat>10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 9/20/2014 11:10 AM EnergyGauge®USA-RaRes2010 Section 405.4.1 Compliant Software Page 5 of 5 ENERGY PERFORMANCE LEVEL (EPL) --�, DISPLAY CARD 117 `" .a ESTIMATED ENERGY PERFORMANCE INDEX* = 39 ca The lower the EnergyPerformance Index, the more efficient the home. '. } 5807 N FLEET LANDING BLVD, ATLANTIC BEACH, FL, 32233- �± 1- New construction or existing Addition 9. Wall Types Insulation Area 2. Single family or multiple family Multi-family a. Frame-Steel, Exterior R=19.0 220.00 ftz b.N/A R= ft 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 0(0) d.N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a.Roof Deck(Unvented) R=19.0 121.00 ft2 6. Conditioned floor area(ft2) 121 b. N/A R= ft2 7. Windows- Description Area c.N/A R= ft2 2 a. U-Factor: Dbl,U=0.30 66.25 ft2 11.Ducts R ft a.Sup:Attic,Ret:Attic,AH:Garage 6 24.2 SHGC: SHGC=0.16 b. U-Factor: Dbl, U=0.33 11.63 ft2 SHGC: SHGC=0.30 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Geothermal Heat Pump 34.0 EER:15.20 SHGC: d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Geothermal Heat Pump 41.5 COP:5.30 Area Weighted Average Overhang Depth: 1.333 ft. Area Weighted Average SHGC: 0.181 8. Floor Types Insulation Area 14.Hot water systems-None required Ca N/A a.Slab-On-Grade Edge Insulation R=0.0 121.00 ft2 a. p EF: b.N/A R= ft2 c. N/A R= ft2 b. Conservation features Heat Recovery Unit 15.Credits CF I certify that this home has complied with the Florida Energy Efficiency Code for Building t7�-EIAEg�RTA Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed � ,,,f`°�� based on installed Code compliant features. r 5 { Builder Signature: Date: Address of New Home:_ City/FL Zip: GOD WE `D *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software r 5807 N FLEET LANDING BLVD; ATLANTIC BEACH, FLORIDA 32233 ADDITION REQUIRES 2740 BTUH OF HEATING AND COOLING TO BE SUPPLIED BY THE EXISTING FLORIDA HEATPUMP SYSTEM 34000 BTUH SEE TOTAL COOLING LOAD CALCULATION BOX ON MANUAL J ADDITION ONLY Residential System Sizing Calculation Summary NAVAL CONTINUING CARE RETIREMENT FOUN1RkcTjt0NTitle: 5807 N FLEET LANDING BLVD FLEE121 ATLANTIC BEACH, FL 32233- HOME FRNT DOOR WEST ORIENT' MANUAL J ADDITION ONLY 9/20/2014 Location for weather data: Jacksonville, FL - Defaults: Latitude(30.5) Altitude(30 ft.) Temp Range(M) Humidit data: Interior RH 50% Outdoor wet bulb 77F Humidity difference 53 r. Winter design temperature(MJ8 99%) 32 F Summer design temperature(MJ8 99%) 93 F Winter setpoint 70 F Summer setpoint 75 F Winter temperature difference 38 F Summer temperature difference 18 F Total heating load calculation 3175 Btuh Total cooling load calculation 2740 Btuh Submitted heating capacity % of calc Btuh Submitted cooling capacity % of calc Btuh Total (Geothermal Heat Pump) 1307.3 41500 Sensible (SHR= 0.74) 1088.9 25160 Heat Pump +,Auxiliary(O.OkW) 1307.3 41500 Latent 2057.3 8840 Total (Geothermal Heat Pum ) 1240.8 34000 WINTER CALCULATIONS Winter Heating Load for 121 sqft) oucscs%> Load component Load s% Window total 78 sqft 901 BtuhDoors(4% wndows(23%) Wall total 134 sgft 512 Btuh Door total 8 sqft 122 Btuh Ceiling total 121 sqft 230 Btuh Floor total 121 sqft 986 Btuh Infiltration 6 cfm 249 Btuh Duct loss 175 Btuh Floars(31%) ceiNngsp%� Subtotal 3175 Btuh Ventilation 0 cfm 0 Btuh waisc,s% TOTAL HEAT LOSS 3175 Btuh SUMMER CALCULATIONS Summer Cooling Load for 121 s ft Load component Load Window total 78 sgft 1381 Btuh Wall total 134 sqft 275 Btuh Door total 8 sqft 93 Btuh Ceiling total 121 sqft 115 Btuh Let-d rRerna(7%) Floor total 0 Btuh ld Gain($%) Infiltration 4 cfm 88 Btuh Internal gain 230 Btuh Ducts(7%) Duct gain 129 Btuh Sens.Ventilation 0 cfm 0 Btuh <<,� s wndows(so%) Blower Load 0 Btuh nfii(g% Total sensible gain 2311 Btuh Latent gain(ducts) 69 Btuh Doors(3%) Latent gain(infiltration) 161 Btuh YvaAs(,0%) Latent gain(ventilation) 0 Btuh Ceiings(4%) Latent gain(internal/occupants/other) 200 Btuh Total latent gain 430 Btuh TOTAL HEAT GAIN 2740 Btuh o WALKER EnergyG I A T7 T77 8th Edition PREPAR DATE: EnergyGauge®/USRFZB v3.1 iza ing Calculations - Summer P-ee tz i d e ntiall Load - Whole House Component Details NAVAL CONTINUING CARE RETIREMENT FOUNIRkJOKitle: 5807 N FLEET LANDING BLVD FLEE121 ATLANTIC BEACH, FL 32233- HOME FRNT DOOR WEST ORIENT' MANUAL J ADDITION ONLY 9/20/2014 Reference City: Jacksonville, FL Temperature Difference: 18.OF(MJ8 99%) Humidity difference: 53gr. House F Component Loads far whole.: mw& Type* Overhang Window Area(sqft) HTM Load -Window I Panes SHGC U InSh IS Omt Len H Gross Shaded UnshadeShaded Unshaded 1 12 NFRC 0.30,0.33 No No S 1.3ft. 2.4ft. 11.6 9.5 2.2 12 15 148 Btuh 2 2 NFRC 0.16,0.30 No No S 1.3ft. 1.0ft. 22.1 22.1 0.0 9 10 193 Btuh 3 2 NFRC 0.16,0.30 No No E 1.3ft. 1.0ft. 22.1 0.5 21.6 9 21 453 Btuh 4 2 NFRC 0.16,0.30 No No E 1.3ft. 11.01t. 22.1 0.5 21.6 9 21 453 Btuh Excursion 133 Btuh Window Total 78 (sqft) 1381 Btuh Walls Type U-Value R-Value Area(sqft) HTM Load Cav/Sheath Frame-Steel-Ext 0.10 19.0/0.0 68.3 2.0 140 Btuh 2 Frame-Steel-Ext 0.10 19.0/0.0 65.8 2.0 135 Btuh Wall Total 134 (sqft) 275 Btuh Doors ,Type Area(sqft) HTM Load 1 Insulated-Exterior 8.0 11.6 93 Btuh Door Total 8 (sqft) 93 Btuh Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM Load 1 Unvented Aftic/Lightrrile 0.050 0.1/19.0 121.0 0.95 115 Btuh ,--Ceiling Total 121 (sqft) 115 Btuh Floors Type R-Value Size HTM Load Slab On Grade 0.0 121 (ft-perimeter) 0.0 0 Btuh Floor Total 121.0 (sqft) 0 Btuh Envelope Subtotal: 1863 Btuh Infiltration Type Average ACH Volume(cuft)Wall Ratio CFM= Load I Natural 0.28 968 1 4.5 88 Btuh Internal Occupants Btuh/occupant Appliance Load gain 1 X 230 + 0 230 Btuh Sensible Envelope Load: 2182 Btuh DUCt IOad Average sealed,Supply(R6.0-Attic),Retum(R6.0-Attic) (DGM of 0.059) 129 Btuh Sensible Load All Zones 2311 Btuh EnergyGauge@) USRFZB 0.1 Page 1 Manual J Summer Calculations Residential Load - Component Details (continued) NAVAL CONTINUING CARE RETIREMENT FOUN®AffjtOtTitle: Climate:FL_JACKSONVILLE_INTL_ARPT 5807 N FLEET LANDING BLVD FLEE121 ATLANTIC BEACH, FL 32233- HOME FRNT DOOR WEST ORIENT' MANUAL J ADDITION ONLY 9/20/2014 WHOLE HOUSE TOTALS Sensible Envelope Load All Zones 2182 Btuh Sensible Duct Load 129 Btuh Total Sensible Zone Loads 2311 Btuh Sensible ventilation 0 Btuh Blower 0 Btuh Whole House Total sensible gain 2311 Btuh Totals for Cooling Latent infiltration gain (for 53 gr. humidity difference) 161 Btuh Latent ventilation gain 0 Btuh Latent duct gain 69 Btuh Latent occupant gain (1.0 people @ 200 Btuh per person) 200 Btuh Latent other gain 0 Btuh Latent total gain 430 Btuh TOTAL GAIN 2740 Btuh EQUIPMENT 1. Geothermal Heat Pump # 34000 Btuh *Key: Window types(Panes-Number and type of panes of glass) (SHGC-Shading coefficient of glass as SHGC numerical value) (U-Window U-Factor) (InSh-Interior shading device: none(No), Blinds(B), Draperies(D)or Roller Shades(R)) - For Blinds:Assume medium color,half closed For Draperies:Assume medium weave, half closed For Roller shades Assume translucent,half closed (IS-Insect screen:none(N), Full(F)or Half(%)) (Ornt-compass orientation) Version 8 EnergyGauge®/USRFZB v3.1 Page 2 System Sizing Calculations - Winter Residential Load - Whole House Component Details NAVAL CONTINUING CARE RETIREMENT FOUN®kcTjt@Kitle: 5807 N FLEET LANDING BLVD FLEE121 ATLANTIC BEACH, FL 32233- Building Type: User HOME FRNT DOOR WEST ORIENT' MANUAL J ADDITION ONLY 9/20/2014 Reference City: Jacksonville, FL (Defaults) Winter Temperature Difference: 38.0 F (MJ8 99%) Component Loads for Whole House Window Panes/Type Frame U Orientation Area s ft X HTM= Load 1 2, NFRC 0.30 Vinyl 0.33 S 11.6 12.5 146 Btuh 2 2, NFRC 0.16 Vinyl 0.30 S 22.1 11.4 252 Btuh 3 2, NFRC 0.16 Vinyl 0.30 E 22.1 11.4 252 Btuh 4 2, NFRC 0.16 Vinyl 0.30 E 22.1 11.4 252 Btuh Window Total 77.9 s ft 901 Btuh Walls Type Ornt. Ueff. R-Value Area X HTM= Load (Cav/Sh) 1 Frame - Steel - Ext (0.100) 19.0/0.0 68 3.82 261 Btuh 2 Frame- Steel - Ext (0.100) 19.0/0.0 66 3.82 251 Btuh Wall Total 134 s ft 512 Btuh Doors Type Storm Ueff. Area X HTM= Load 1 Insulated - Exterior, n (0.400) 8 15.2 122 Btuh Door Total 8 s ft 122Btuh Ceilings Type/Color/Surface Ueff. R-Value Area X HTM= Load 1 Unvent Attic/UTile (0.050) 0.1/19.0 121 1.9 230 Btuh ceiling Total 121 s ft 230Btuh Floors Type Ueff. R-Value Size X HTM= Load 1 Slab On Grade (1.180) 0.0 22.0 ft(perim.) 44.8 986 Btuh Floor Total 121 s ft 986 Btuh Envelope Subtotal: 2751 Btuh Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Natural 0.37 968 1.00 6.0 249 Btuh Duct load Average sealed, R6.0, Supply(Att), Return(Att) (DLM of 0.058) 175 Btuh All Zones Sensible Subtotal All Zones 3175 Btuh HOLE HOUSE TOTALS Subtotal Sensible Heat Loss 3175 Btuh Totals for Heating Ventilation Sensible Heat Loss 0 Btuh Total Heat Loss 3175 Btuh EnergyGauge®/USRFZB 0.1 Page 1 Manual J Winter Calculations Residential Load - Component Details (continued) NAVAL CONTINUING CARE RETIREMENT FOUN®Affjt0tTitle: 5807 N FLEET LANDING BLVD FLEE121 ATLANTIC BEACH, FL 32233- Building Type: User HOME FRNT DOOR WEST ORIENT' MANUAL J ADDITION ONLY 9/20/2014 EQUIPMENT F. Geothermal Heat Pump # 41500 Btuh Key:Window types-NFRC(Requires U-Factor and Shading coefficient(SHGC)of glass as numerical values) or-Glass as'Clear'or'Tint'(Uses U-Factor and SHGC defaults) U-(Window U-Factor) HTM-(ManualJ Heat Transfer Multiplier) Version 8 EnergyGauge@ I USRFZB v3.1 Page 2 5807 N FLEET LANDING BLVD; ATLANTIC BEACH, FLORIDA 32233 EXISTING FLORIDA HEATPUMP SYSTEM EER: COP: DESIGN COOLING BTUH WHOLE HOUSE: ADDITION ONLY: AVAILABLE STATIC PRESSURE: TOTAL CFM: TOTAL EFFECTIVE LENGTH: PERFORMANCE METHOD: DUCT MATERIAL: R6 VINYL FLEX SUPPLY BRANCH DETAIL TABLE ROOM NAME COOLING CFM BRANCH SIZE LINEAR FT DUCT MATERIAL ADDITION 100 CFM 6" 20' VINYL FLEX TOTAL 100 CFM 20 LN (ft) CITY OF ATLANTIC BEACH SUPPLY TRUNK DETAIL TABLE LOCATION DESIGN BTUH TRUNK SIZE DUCT MATERIAL EXISTING EXISTING EXISTING EXISTING A�DrT"ION too CP M Cary N&(2, iv �xis�NC� 5807 N FLEET LANDING BLVD; ATLANTIC BEACH, FLORIDA 32233 MANUAL J FOR THE EXISTING HOUSE INCLUDING THE ADDITION Residential System Sizing Calculation Summary NAVAL CONTINUING CARE RETIREMENT FOUN1RkcTjt0Kitle: 5807 N FLEET LANDING BLVD FLEE1882 ATLANTIC BEACH, FL 32233- WEST ORIENTATION WHOLE HOUSE W/ADDITION 9/19/2014 Location for weather data: Jacksonville, FL - Defaults: Latitude(30.5) Altitude(30 ft.) Temp Range(M) Humidity data: Interior RLL50%) Outdoor wet bulb77F Humiditydifference 53 r. Winter design temperature(MJ8 99%) 32 F Summer design temperature(MJ8 99%) 93 F Winter setpoint 70 F Summer setpoint 75 F Winter temperature difference 38 F Summer tem erature difference 18 F Total heating load calculation 27120 Btuh Total cooling load calculation 32531 Btuh Submitted heating capacity % of calc Btuh Submitted cooling capacity % of Calc Btuh Total (Geothermal Heat Pump) 153.0 41500 Sensible (SHR = 0.74) 103.9 25160 Heat P rnp -1 Auxiliary(0.0kW) 153.0 41500 Latent 106.3 8840 Total Geothermal Heat Pum 104.5 34000 WINTER CALCULATIONS Winter Heating Load for 1882 sqft) Ducts(10%) VYYntlovvs(12%) Load component Load Window total 270 sqft 3359 Btuh Wall total 1610 sqft 6244 Btuh cernas(1a% Door total 48 sqft 730 Btuh Ceiling total 1950 sqft 3715 Btuh Floor total See detail report 5964 Btuh Doors(3%) Infiltration 104 cfm 4326 Btuh Duct loss 2783 Btuh Subtotal 27120 Btuh W.ft(23%) Ventilation 0 cfm 0 Btuh Fors( %' TOTAL HEAT LOSS 27120 Btuh SUMMER CALCULATIONS Summer Cooling Load for 1882 s ft Load component Load Window total 270 sqft 4525 Btuh Wall total 1610 sqft 2788 Btuh Door total 48 sqft 557 Btuh Ceiling total 1950 sqft 1799 Btuh LHtz a rder 1(14% WN dow (14%) Floor total 0 Btuh Infiltration 78 cfm 1537 Btuh Internal gain 11090 Btuh Duct gain 1918 Btuh vsns(s%� Sens.Ventilation 0 cfm 0 Btuh [ Blower Load 0 Btuh l D..-(2%) Total sensible gain 24214 Btuh trri 0-eInB9%,` Latent gain(ducts) 1119 Btuh Infil(13%) Latent gain(infiltration) 2797 Btuh Latent gain(ventilation) 0 Btuh Dua cs°b� Latent gain(intern al/occupants/other) 4400 Btuh Total latent gain 8317 Btuh TOTAL HEAT GAIN 32531 Btuh EnergyGaf)�j�i W111 8th Edition PREPARE S tl� DATE: EnergyGauge®/USRFZB 0.1 System sizing Calculations - Summer Ra iental load - Thole House Component Details NAVAL CONTINUING CARE RETIREMENT FOUNPMjdKitle: 5807 N FLEET LANDING BLVD FLEE1882 ATLANTIC BEACH, FL 32233- WEST ORIENTATION WHOLE HOUSE W/ADDITION 9/19/2014 Reference City: Jacksonville, FL Temperature Difference: 18.OF(MJ8 99%) Humidity difference: 53gr. Component Goads for Whole House eh � � �� .. SEI„'�.�'�. �w..." � _--:..� "4� xacr. ., - ...i� ,r>• �` Type` Overhang Window Area(sqft) HTM Load Window Panes SHGC U InSh IS Ornt Len H t Gross ShadedUnshaded Shaded Unshaded 1 2 NFRC 0-29'0 .29,0.32 No No S 11.0f 1.5ft. 21.7 21.7 0.0 12 14 257 Btuh 2 2 NFRC 0.29,0.32 No No W 12.Of 1.5ft. 8.9 8.9 0.0 12 34 106 Btuh 3 2 NFRC 0.29,0.32 No No S 1.3ft. 2.2ft. 13.7 13.6 0.1 12 14 162 Btuh 4 2 NFRC 0.29,0.34 No No S 1.3ft. 0.8ft. 3.8 3.8 0.0 12 15 46 Btuh 5 2 NFRC 0.29,0.32 No No S 1.3ft. 2.2ft. 13.7 13.6 0.1 12 14 162 Btuh 6 2 NFRC 0.29,0.34 No No S 1.3ft. 0.8ft. 3.8 3.8 0.0 12 15 46 Btuh 7 2 NFRC 0.29,0.34 No No S 1.3ft. 0.8ft. 3.8 3.8 0.0 12 15 46 Btuh 8 2 NFRC 0.29,0.34 No No S 1.3ft. 0.8ft. 3.8 3.8 0.0 12 15 46 Btuh 9 2 NFRC 0.29,0.32 No No S 1.3ft. 0.5ft. 49.0 49.0 0.0 12 14 579 Btuh 10 2 NFRC 0.29,0.32 No No S 1.3ft. 1.2111. 16.5 16.4 0.1 12 14 196 Btuh 11 2 NFRC 0.29,0.32 No No S 1.3ft. 1.2ft. 16.5 16.4 0.1 12 14 196 Btuh 12 2 NFRC 0.30,0.33 No No S 1.3ft. 2.41t. 11.6 9.5 2.2 12 15 148 Btuh 13 2 NFRC 0.16,0.30 No No S 1.3ft. 1.0ft. 22.1 22.1 0.0 9 10 193 Btuh 14 2 NFRC 0.16,0.30 No No E 1.3ft. 1.Oft. 22.1 0.5 21.6 9 21 453 Btuh 15 2 NFRC 0.16,0.30 No No E 1.3ft. 1.0ft. 22.1 0.5 21.6 9 21 453 Btuh 16 2 NFRC 0.29,0.32 No No E 1.3ft. 2.8ft. 10.1 0.0 10.1 12 34 340 Btuh 17 2 NFRC 0.29,0.34 No No E 1.3ft. 0.5ft. 5.4 1.4 4.0 12 34 154 Btuh 18 2 NFRC 0.29,0.32 No No E 1.3ft. 2.8ft. 10.1 0.0 10.1 12 34 340 Btuh 19 2 NFRC 0.29,0.34 No No E 1.3ft. 0.5ft. 5.4 1.4 4.0 12 34 154 Btuh 20 2 NFRC 0.29,0.76 Skylight S (45deg.) 6.0 0.0 6.0 12 74 446 Btuh Window Total 1 270 (sqft) 4525 Btuh Walls Type U-Value R-Value Area(sqft) HTM Load Cav/Sheath 1 Frame-Steel-Adj 0.12 11.0/0.0 116.0 2.1 248 Btuh 2 Frame-Steel-Ext 0.10 19.0/0.0 48.3 2.0 99 Btuh 3 Frame-Steel-Ext 0.10 19.0/0.0 50.0 2.0 102 Btuh 4 Frame-Steel-Ext 0.10 19.0/0.0 51.1 2.0 105 Btuh 5 Frame-Steel-Ext 0.10 19.0/0.0 117.5 2.0 241 Btuh 6 Frame-Steel-Ext 0.10 19.0/0.0 20.0 2.0 41 Btuh 7 Frame-Steel-Ext 0.10 19.0/0.0 55.0 2.0 113 Btuh 8 Frame-Steel-Ext 0.10 19.0/0.0 20.0 2.0 41 Btuh 9 Frame-Steel-Ext 0.10 19.0/0.0 126.9 2.0 260 Btuh 10 Frame-Steel-Ext 0.10 19.0/0.0 20.0 2.0 41 Btuh 11 Frame-Steel-Ext 0.10 19.0/0.0 68.3 2.0 140 Btuh 12 Frame-Steel-Ext 0.10 19.0/0.0 65.8 2.0 135 Btuh 13 Frame-Steel-Ext 0.10 19.0/0.0 20.0 2.0 41 Btuh 14 Frame-Steel-Ext 0.10 19.0/0.0 138.9 2.0 284 Btuh 15 Frame-Steel-Nei 0.10 19.0/0.0 660.0 1.2 795 Btuh 16 Frame-Steel-Ext 0.12 11.0/0.0 32.0 3.2 103 Btuh Wall Total 1610 (sqft) 2788 Btuh Doors Type Area (sqft) HTM Load 1 Insulated-Garage 20.0 11.6 232 Btuh 2 Insulated-Exterior 20.0 11.6 232 Btuh 3 Insulated-Exterior 8.0 11.6 93 Btuh Door Total 48 (sqft) 557 Btuh Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM Load 1 Unvented Attic/LighUTile 0.050 0.1/19.0 1761.0 0.95 1673 Btuh 2 Knee Wall/Light/Tile 0.054 0.1/19.0 68.0 0.16 11 Btuh 3 Unvented Attic/Light/Tile 0.050 0.1119.0 121.0 0.95 115 Btuh Ceiling Total 1950 (sqft) 1799 Btuh EnergyGauge®/USRFZB v3.1 Page 1 Manual J Summer Calculations Residential Load - Component Details (continued) NAVAL CONTINUING CARE RETIREMENT FOUN®title: Climate:FL_JACKSONVILLE_INTL_ARPT 5807 N FLEET LANDING BLVD FLEE1882 ATLANTIC BEACH, FL 32233- WEST ORIENTATION WHOLE HOUSE W/ADDITION 9/19/2014 Floors Type R-Value Size HTM Load 1 Slab On Grade 0.0 1761 (ft-perimeter) 0.0 0 Btuh 2 Slab On Grade 0.0 121 (ft-perimeter) 0.0 0 Btuh Floor Total 1882.0 (sqft) 0 Btuh Envelope Subtotal: 9669 Btuh Infiltration'Type Average ACH Volume(cuft)Wall Ratio CFM= Load Natural 0.28 16817 1 77.7 1537 Btuh Internal Occupants Btuh/occupant Appliance Load gain 3 X 230 + 10400 11090 Btuh Sensible Envelope Load: 22296 Btuh Duct load Average sealed,Supply(R6.0-Attic),Retum(R6.0-Attic) (DGM of 0.086) 1918 Btuh Sensible Load All Zones 24214 Btuh EnergyGauge®/USRFZB v3.1 Page 2 Manual J Summer Calculations Residential Load - Component Details (continued) NAVAL CONTINUING CARE RETIREMENT FOUN[Rkffjk@ Title: Climate:FL_JACKSONVILLE_INTL_ARPT 5807 N FLEET LANDING BLVD FLEE1882 ATLANTIC BEACH, FL 32233- WEST ORIENTATION WHOLE HOUSE W/ADDITION 9/19/2014 WHOLE HOUSE TOTALS Sensible Envelope Load All Zones 22296 Btuh Sensible Duct Load 1918 Btuh Total Sensible Zone Loads 24214 Btuh Sensible ventilation 0 Btuh Blower 0 Btuh Whole House Total sensible gain 24214 Btuh Totals for Cooling Latent infiltration gain (for 53 gr. humidity difference) 2797 Btuh Latent ventilation gain 0 Btuh Latent duct gain 1119 Btuh Latent occupant gain (3.0 people @ 200 Btuh per person) 600 Btuh Latent other gain 3800 Btuh Latent total gain 8317 Btuh TOTAL GAIN 32531 Btuh EQUIPMENT --T— 1. Geothermal Heat Pump # 34000 Btuh "Key: Window types(Panes-Number and type of panes of glass) (SHGC-Shading coefficient of glass as SHGC numerical value) (U-Window U-Factor) (InSh-Interior shading device: none(No), Blinds(B), Draperies(D)or Roller Shades(R)) - For Blinds.Assume medium color,half closed For Draperies:Assume medium weave,half closed For Roller shades:Assume translucent, half closed (IS-Insect screen:none(N),Full(F)or Half(%)) I (Ornt-compass orientation) `x Version 8 EnergyGauge®/USRFZB v3.1 Page 3 This combination qualifies for a Federal Energy I , Efficiency Tax Credit when placed in service 0%3 an ILI Efficiency Jan 1,2006 and Dec 31,2016 and used in www.ahridirectory.org GLHP or GWHP application point. Cututif at f PI-0--duct Ratings AHRI Certified Reference Number: 384232 Date: 9/18/2014 tStatus: Discontinued Product:Water/Brine to Air Heat Pump Packaged Unit Model Number: ES036-ICF/HZJVT Manufacturer: FHP MANUFACTURING COMPANY Trade/Brand name: ENVIRO-SAVER Rated as follows in accordance with ANSI/AHRI/ASHRAE/ISO Standard 13256-1 for Water-to-Air and Brine-To-Air Heat Pumps and subject to verification of rating accuracy by AHRI-sponsored,independent,third party testing: Cooling Air Flow Rate: 1200.0/ 1200.0 Heating Air Flow Rate: 1200.0/ 1200.0 WLHP (Water-Loop Heat Pumps) Full Load Cooling Capacity(Btuh) 34000/34000 0 Cooling EER Rating(Btu h/watt) 15.20/15.20 0.00 Cooling Fluid Flow Rate(gpm) 9.00/9.00 0.00 Heating Capacity(Btuh) 41500/41500 0 Heating COP(watt/watt) 5.30/5.30 0.00 Heating Fluid Flow Rate(gpm) 9.00/9.00 0.00 GWHP(Ground-Water Heat Pumps) Cooling Capacity(Btuh) 38500/38500 0 Cooling EER Rating(Btu h/watt) 22.80/22:80 0.00 Cooling Fluid Flow Rate(gpm) 9.00/9.00 0.00 Heating Capacity(Btuh) 33500/33500 0 Heating COP(watt/watt) 4.60/4.60 0.00 Heating Fluid Flow Rate(gpm) 9.00/9.00 0.00 GLHP (Ground-Loop Heat Pumps) Cooling Capacity(Btuh) 35500/35500 0 Cooling EER Rating(Btuh/watt) 17.601 17.60 0.00 Cooling Fluid Flow Rate(gpm) 9.00/9.00 0.00 Heating Capacity(Btuh) 26500/26500 0 Heating COP(watt/watt) 3.80/3.80 0.00 Heating Fluid Flow Rate(gpm) 9.00/9.00 0.00 Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed In the directory at www,ahritfirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for Individual,per and I„ confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated; entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual, AIR-CONDITIONING.HEATING. personal and confidential reference. C &REFRIGERATION INSTITUTE CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org,click on"Verify Certificate"link we make life better- and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above,and the Certificate No.,which Is listed at bottom right 130555535360997235 ©2014 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: System Sizing Calculations - Winter Residential Load - Whole House Component Details NAVAL CONTINUING CARE RETIREMENT FOUN®MjtdNTitle: 5807 N FLEET LANDING BLVD FLEE1882 ATLANTIC BEACH, FL 32233- Building Type: User WEST ORIENTATION WHOLE HOUSE W/ADDITION 9/19/2014 Reference City: Jacksonville, FL (Defaults) Winter Temperature Difference: 38.0 F (MJ8 99%) Component Loads for Whole House Window Panes/Type Frame U Orientation Area s ft X HTM= Load 1 2, NFRC 0.29 Vinyl 0.32 S 21.7 12.2 264 Btuh 2 2, NFRC 0.29 Vinyl 0.32 W 8.9 12.2 109 Btuh 3 2, NFRC 0.29 Vinyl 0.32 S 13.7 12.2 167 Btuh 4 2, NFRC 0.29 Vinyl 0.34 S 3.8 12.9 49 Btuh 5 2, NFRC 0.29 Vinyl 0.32 S 13.7 12.2 167 Btuh 6 2, NFRC 0.29 Vinyl 0.34 S 3.8 12.9 49 Btuh 7 2, NFRC 0.29 Vinyl 0.34 S 3.8 12.9 49 Btuh 8 2, NFRC 0.29 Vinyl 0.34 S 3.8 12.9 49 Btuh 9 2, NFRC 0.29 Vinyl 0.32 S 49.0 12.2 596 Btuh 10 2, NFRC 0.29 Vinyl 0.32 S 16.5 12.2 201 Btuh 11 2, NFRC 0.29 Vinyl 0.32 S 16.5 12.2 201 Btuh 12 2, NFRC 0.30 Vinyl 0.33 S 11.6 12.5 146 Btuh 13 2, NFRC 0.16 Vinyl 0.30 S 22.1 11.4 252 Btuh 14 2, NFRC 0.16 Vinyl 0.30 E 22.1 11.4 252 Btuh 15 2, NFRC 0.16 Vinyl 0.30 E 22.1 11.4 252 Btuh 16 2, NFRC 0.29 Vinyl 0.32 E 10.1 12.2 123 Btuh 17 2, NFRC 0.29 Vinyl 0.34 E 5.4 12.9 70 Btuh 18 2, NFRC 0.29 Vinyl 0.32 E 10.1 12.2 123 Btuh 19 2, NFRC 0.29 Vinyl 0.34 E 5.4 12.9 70 Btuh 20 2, NFRC 0.29 Vinyl 0.76 SKY(S) 6.0 28.8 173 Btuh Window Total 270.2 s ft 3359 Btuh Walls Type Ornt. Ueff. R-Value Area X HTM= Load (Cav/Sh) 1 Frame - Steel -Adj (0.119) 11.0/0.0 116 4.51 Btuh 184 2 Frame- Steel - Ext (0.100) 19.0/0.0 48 3.82 184 Btuh 3 Frame - Steel - Ext (0.100) 19.0/0.0 50 3.82 191 Btuh 4 Frame - Steel - Ext (0.100) 19.0/0.0 51 3.82 195 Btuh 5 Frame - Steel - Ext (0.100) 19.0/0.0 118 3.82 448 Btuh 6 Frame - Steel - Ext (0.100) 19.0/0.0 20 3.82 76 Btuh 7 Frame - Steel - Ext (0.100) 19.0/0.0 55 3.82 210 Btuh 8 Frame - Steel - Ext (0.100) 19.0/0.0 20 3.82 76 Btuh 9 Frame - Steel - Ext (0.100) 19.0/0.0 127 3.82 484 Btuh 10 Frame - Steel - Ext (0.100) 19.0/0.0 20 3.82 76 Btuh 11 Frame - Steel - Ext (0.100) 19.0/0.0 68 3.82 261 Btuh 12 Frame- Steel - Ext (0.100) 19.0/0.0 66 3.82 251 Btuh 13 Frame - Steel - Ext (0.100) 19.0/0.0 20 3.82 76 Btuh 14 Frame - Steel - Ext (0.100) 19.0/0.0 139 3.82 530 Btuh 15 Frame- Steel - Nei (0.100) 19.0/0.0 660 3.82 2518 Btuh 16 Frame - Steel - Ext (0.119) 11.0/0.0 32 4.51 144 Btuh Wall Total 1610 s ft 6244 Btuh EnergyGauge(g)/USRFZB v3.1 Page 1 Manual J Winter Calculations Residential Load - Component Details (continued) NAVAL CONTINUING CARE RETIREMENT FOUN®kdjtdNTitle: 5807 N FLEET LANDING BLVD FLEE1882 ATLANTIC BEACH, FL 32233- Building Type: User WEST ORIENTATION WHOLE HOUSE W/ADDITION 9/19/2014 Doors Type Storm Ueff. Area X HTM= Load 1 Insulated - Garage, n (0.400) 20 15.2 304 Btuh 2 Insulated - Exterior, n (0.400) 20 15.2 304 Btuh 3 Insulated - Exterior, n (0.400) 8 15.2 122 Btuh Door Total 48(sriffi 730Btuh Ceilings Type/Color/Surface Ueff. R-Value Area X HTM= Load 1 Unvent Attic/L/Tile (0.050) 0.1/19.0 1761 1.9 3346 Btuh 2 Knee Wall/L/Tile (0.054) 0.1/19.0 68 2.0 139 Btuh 3 Unvent Attic/L/Tile (0.050) 0.1/19.0 121 1.9 230 Btuh Ceiling Total 1950 s ft 371513tuh Floors Type Ueff. R-Value Size X HTM= Load 1 Slab On Grade (1.180) 0.0 111.0 ft(perim.) 44.8 4977 Btuh 2 Slab On Grade (1.180) 0.0 22.0 ft(perim.) 44.8 986 Btuh Floor Total 1882 s ft 5964 Btuh Envelope Subtotal: 20011 Btuh Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Natural 0.37 16817 1.00 103.6 4326 Btuh Duct load Average sealed, R6.0, Supply(Att), Return(Att) (DLM of 0.114) 2783 Btuh All Zones Sensible Subtotal All Zones 27120 Btuh HOLE HOUSE TOTALS Subtotal Sensible Heat Loss 27120 Btuh Totals for Heating Ventilation Sensible Heat Loss 0 Btuh Total Heat Loss 27120 Btuh EQUIPMENT [1. Geothermal Heat Pump # 4=Btuh EnergyGaugeg/USRFZB 0.1 Page 2 Manual J Winter Calculations Residential Load - Component Details (continued) NAVAL CONTINUING CARE RETIREMENT FOUN®kJj0NTitle: 5807 N FLEET LANDING BLVD FLEE1882 ATLANTIC BEACH, FL 32233- Building Type: User WEST ORIENTATION WHOLE HOUSE W/ADDITION 9/19/2014 Key:Window types-NFRC(Requires U-Factor and Shading coefficient(SHGC)of glass as numerical values) or-Glass as'Clear'or'Tint'(Uses U-Factor and SHGC defaults) U-(Window U-Factor) HTM-(ManualJ Heat Transfer Multiplier) Version 8 EnergyGauge@/USRFZB v3.1 Page 3 1�:Ly City of Atlantic Beach APPLICATION NUMBER Building Department (To be assigned by the Building Department.) 800 Seminole Road Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 • Fax(904)247-5845 L0 E-mail: building-dept@coa.b.us Date routed: City web-site: http://wwe; ,. ab.us APPLICATION REVIEW AND TRACKING FORM �' SFT dress: �/� De artment review required Ye No Property Ad Building Applicant: /V C�� anning &Zoning / Q Tree Administrator Project: �/�C /Q �l�- C� Public Works Public Utilities Public Safety Fire Services Review fee $ Dept'SignaWre Other Agency Review Permit Required Review or Receiptof Permit Verified By Date Florida Dept. of Environm(,.i"' 1 Protection Florida Dept. of Transportaii;n St.Johns River Water Mar: ement District Army Corps of Engineers Division of Hotels and Res<<-,rants Division of Alcoholic Bever ,es and Tobacco Other: APPLICATION STATUS Reviewing Department First Review. pproved. ❑Denied. (Circle one.) Comments: `A ro� BUILDI 'U PLANNING &ZONINGReviewed by: IT Date: TREE ADMIN. Second ReN ❑Approved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Reviev ❑Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 05/14/09