Loading...
5808 Fleet Landing 2014 screen room CITY OF ATLANTIC BEACH 1 j 800 SEMINOLE ROAD !� ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 RESIDENTIAL ALT/OTHER MUST eALL BY 4PM FOR NEXT DAY!NSPEGRON, 247 58964 JOB INFORMATION: Job ID: 14-RAAR-99 Job Type: RESIDENTIAL ALTERATION Description: ENCLOSE PORCH FL330.1 Estimated Value: $6,000.00 Issue Date: 9/30/2014 Expiration Date: 3/29/2015 PROPERTY ADDRESS: Address: 5808 FLEET LANDING BLVD RE Number: LOC ID-0000 PROPERTY OWNER: Name: NAVAL CONTINUING CARE Address: GENERAL CONTRACTOR INFORMATION: Name: NCCRF Address: Phone: - - PERMIT INFORMATION: FEES: PLAN CHECK FEES $40.00 BUILDING PERMIT FEE $80.00 STATE DCA SURCHARGE $1.20 STATE DBPR SURCHARGE $1.20 Total Payments: $122.40 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. F ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD FILE COP+N ' _ STIMATED ENERGY PERFORMANCE INDEX* = 40 The lower the EnergyPerformance Index, the more efficient the home. 5808 N FLEET LANDING BLVD, ATLANTIC BEACH, FL, 32233- 1. New construction or existing Addition 9. Wall Types Insulation Area 2. Single family or multiple family Multi-family a.Frame-Steel,Exterior R=19.0 220.00 ft2 b. N/A R= ft2 3. Number of units,if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 0(0) d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types Insulation Area a.Roof Deck(Unvented) R=19.0 121.00 ft2 6. Conditioned floor area(ft2) 121 b. N/A R= ft2 7. Windows- Description Area c.N/A R= ft2 a. U-Factor: Dbl,U=0.30 66.25 ft2 11.Ducts R ft a.Sup:Attic,Ret:Attic,AH:Garage 6 24.2 SHGC: SHGC=0.16 b. U-Factor: Dbl,U=0.33 11.63 ft2 SHGC: SHGC=0.30 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Geothermal Heat Pump 34.0 EER:15.20 SHGC: d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a.Geothermal Heat Pump 41.5 COP:5.30 Area Weighted Average Overhang Depth: 1.333 ft. Area Weighted Average SHGC: 0.181 8. Floor Types Insulation Area 14.Hot water systems-None required Cap:N/A a.Slab-On-Grade Edge Insulation R=0.0 12 1.00 ft2 a. EF: b.N/A R= ft2 c. N/A R= ft2 b. Conservation features Heat Recovery Unit 15.Credits CF I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) �y0 't ST,y��o in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. 16. Builder Signature: Date: Address of New Home: City/FL Zip: yes WE *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software 5808 N FLEET LANDING BLVD; ATLANTIC BEACH, FLORIDA 32233 ADDITION REQUIRES 2769 BTUH OF HEATING AND COOLING TO BE SUPPLIED BY THE EXISTING FLORIDA HEATPUMP SYSTEM 34000 BTUH SEE TOTAL COOLING LOAD CALCULATION BOX ON MANUAL J ADDITION ONLY Residential System Sizing Calculation Summary NAVAL CONTINUING CARE RETIREMENT FOUN1Rkdj1@NTitle: 5808 N FLEET LANDING BLVD FLEE121 ATLANTIC BEACH, FL 32233- HOME FRNT DOOR WEST ORIENT' MANUAL J ADDITION ONLY 9/20/2014 Location for weather data. Jacksonville, FL - Defaults: Latitude(30.5) Altitude(30 ft.) Temp Range(M) Humidity data: Interior RH 50% Outdoor wet bulb 77F Humidity difference 53 r. Winter design temperature(MJ8 99%) 32 F Summer design temperature(MJ8 99%) 93 F Winter setpoint 70 F Summer setpoint 75 F Winter temperature difference 38 F Summer temperature difference 18 F Total heating load calculation 3175 Btuh Total cooling load calculation 2769 Btuh Submitted heating capacity % of calc Btuh Submitted cooling capacity % of calc Btuh Total (Geothermal Heat Pump) 1307.3 41500 Sensible (SHR = 0.74) 1075.7 25160 Heat Pump +Auxiliary(O.OkW) 1307.3 41500 Latent 2057.2 8840 Tota! Geothermal Heat Pum 1228.1 34000 WINTER CALCULATIONS Winter Heating Load for 121 sqft) Diw:ts(F%) Load component Load Window total 78 sqft 901 Btuh vw aows(2s%) Doors(4%) Wall total 134 sqft 512 Btuh Door total 8 sqft 122 Btuh Ceiling total 121 sqft 230 Btuh Floor total 121 sqft 986 Btuh Infiltration 6 cfm 249 Btuh Duct loss 175 Btuh Floors(31 Subtotal 3175 Btuh Ventilation 0 cfm 0 Btuh TOTAL HEAT LOSS 3175 Btuh SUMMER CALCULATIONS Summer Cooling Load for 121 sqft) Load component Load Window total 78 sqft 1407 Btuh Wall total 134 sqft 275 Btuh Door total 8 sqft 93 Btuh Ceiling total 121 sqft 115 Btuh Letenl irderna(79G) Floor total 0 Btuh IrR.Ga n(8%) Infiltration 4 cfm 88 Btuh Internal gain 230 Btuh Duct gain 131 Btuh Sens.Ventilation 0 cfm 0 Btuh Blower Load 0 Btuh nfl cs%) VWKbW'(51�`� Total sensible gain 2339 Btuh Latent gain(ducts) 69 Btuh 000rsc396) Latent gain(infiltration) 161 Btuh Nels(,D%) Latent gain(ventilation) 0 Btuh CeJlings(4%1 Latent gain(internal/occupants/other) 200 Btuh Total latent gain 430 Btuh TOTAL HEAT GAIN 2769 Btuh Energy WNW�.' 8th Edition PREPA 9 . ER r DATE: I/Owl IV EnergyGauge®/USRFZB 0.1 !-1k%t!Qtem SWng Calculations - Summer 3j I. I I r? s;�de ,Re ,ntial Load - Whole House Component Details NAVAL CONTINUING CARE RETIREMENT FOUNPAWNTitle: 5808 N FLEET LANDING BLVD FLEE121 ATLANTIC BEACH, FL 32233- HOME FRNT DOOR WEST ORIENT' MANUAL J ADDITION ONLY 9/20/2014 Reference City: Jacksonville, FL Temperature Difference: 18.OF(MJ8 99%) Humidity difference: 53gr. U!", Vi Componen It Loads for ""�#�H N "2U g 0 7 Type* Overhang Window Area(sqft) HTM Load Window Panes SHGC U InSh IS Ornt_ Len H Gross ShadedUnshaded Shaded Unshaded 1 2 NFRC 0.30,0.33 No No N 1.3ft. 2.4ft. 11.6 0.0 11.6 12 12 142 Btuh 2 2 NFRC 0.16,0.30 No No N 1.3ft. 1.0ft. 22.1 0.0 22.1 9 9 193 Btuh 3 2 NFRC 0.16,0.30 No No E 1.3ft. 1.0ft. 22.1 0.5 21.6 9 21 453 Btuh 4 2 NFRC 0.16,0.30 No No E 1.3ft. 1.0ft. 22.1 0.5 21.6 9 21 453 Btuh Excursion 165 Btuh Window Total 78(sqft) 1407 Btuh Walls Type LI-Value R-Value Area(sqft) HTM Load Cav/Sheath 1 Frame-Steel-Ext 0.10 19.0/0.0 68.3 2.0 140 Btuh 2 Frame-Steel-Ext 0.10 19.0/0.0 65.8 2.0 135 Btuh Wall Total 134(sqft) 275 Btuh Doors Type Area (sqft) HTM Load 1 Insulated-Exterior 8.0 11.6 93 Btuh Door Total 8(sqft) 93 Btuh Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM Load 1 Unvented AttictLightfFile 0.050 0.1/19.0 121.0 0.95 115 Btuh Ceiling Total 121 (sqft) 115 Btuh Floors Type R-Value Size HTM Load 1 Slab On Grade 0.0 121 (ft-perimeter) 0.0 0 Btuh Floor Total 12 1.0 (sqft) 0 Btuh EnvelopeSubtotal: 1890 Btuh ,Infiltration Type Average ACH Volume(cuft)Wall Ratio CFM= Load Natural 0.28 968 1 4.5 88 Btuh Internal Occupants Btuh/occupant Appliance Load gain 1 X 230 + 0 230 Btuh Sensible Envelope Load: 2208 Btuh Duct load Average sealed,Supply(R6.0-Attic), Return(R6.0-Attic) (DGM of 0.059) 131 Btuh Sensible Load All Zones 2339 Btuh EnergyGauge@/USRFZB v3.1 Page 1 Manual J Summer Calculations Residential Load - Component Details (continued) NAVAL CONTINUING CARE RETIREMENT FOUNIRATjtO Ifitle: Climate:FL_JACKSONVILLE_INTL_ARPT 5808 N FLEET LANDING BLVD FLEE121 ATLANTIC BEACH, FL 32233- HOME FRNT DOOR WEST ORIENT' MANUAL J ADDITION ONLY 9/20/2014 WHOLE HOUSE TOTALSAl .1 Sensible Envelope Load All Zones 2208 Btuh Sensible Duct Load 131 Btuh Total Sensible Zone Loads 2339 Btuh Sensible ventilation 0 Btuh Blower 0 Btuh Whole House Total sensible gain 2339 Btuh Totals for Cooling Latent infiltration gain (for 53 gr. humidity difference) 161 Btuh Latent ventilation gain 0 Btuh Latent duct gain 69 Btuh Latent occupant gain (1.0 people @ 200 Btuh per person) 200 Btuh Latent other gain 0 Btuh Latent total gain 430 Btuh TOTAL GAIN 2769 Btuh EQUIPMENT 1. Geothermal Heat Pump # 34000 Btuh 'Key: Window types(Panes-Number and type of panes of glass) (SHGC-Shading coefficient of glass as SHGC numerical value) (U-Window U-Factor) (InSh-Interior shading device:none(No),Blinds(B), Draperies(D)or Roller Shades(R)) - For Blinds:Assume medium color, half closed For Draperies:Assume medium weave,half closed For Roller shades:Assume translucent,half closed (IS-Insect screen:none(N), Full(F)or Half(''/z)) (Ornt-compass orientation) Version 8 EnergyGauge®/USRFZB v3.1 Page 2 System Sizing Calculations - Winter Residential Load - Whole House Component Details NAVAL CONTINUING CARE RETIREMENT FOUNII kffjt0 Vritle: 5808 N FLEET LANDING BLVD FLEE121 ATLANTIC BEACH, FL 32233- Building Type: User HOME FRNT DOOR WEST ORIENT' MANUAL J ADDITION ONLY 9/20/2014 Reference City: Jacksonville, FL (Defaults) Winter Temperature Difference: 38.0 F (MJ8 99%) Component Loads for Whole House Window Panes/Type Frame U Orientation Area s ft X HTM= Load 1 2, NFRC 0.30 Vinyl 0.33 N 11.6 12.5 146 Btuh 2 2, NFRC 0.16 Vinyl 0.30 N 22.1 11.4 252 Btuh 3 2, NFRC 0.16 Vinyl 0.30 E 22.1 11.4 252 Btuh 4 2, NFRC 0.16 Vinyl 0.30 E 22.1 11.4 252 Btuh Window Total 77.9 s ft 901 Btuh Walls Type Ornt. Ueff. R-Value Area X HTM= Load (Cav/Sh) 1 Frame - Steel - Ext (0.100) 19.0/0.0 68 3.82 261 Btuh 2 Frame - Steel - Ext (0.100) 19.0/0.0 66 3.82 251 Btuh Wall Total 134 s ft 512 Btuh Doors Type Storm Ueff. Area X HTM= Load 1 Insulated - Exterior, n (0.400) 8 15.2 122 Btuh Door Total 8 s ft 12213tuh Ceilings Type/Color/Surface Ueff. R-Value Area X HTM= Load 1 Unvent Attic/L/Tile (0.050) 0.1/19.0 121 1.9 230 Btuh Ceiling Total 121 s ft 23013tuh Floors Type Ueff. R-Value Size X HTM= Load 1 Slab On Grade (1.180) 0.0 22.0 ft(perim.) 44.8 986 Btuh Floor Total 121 s ft 986 Btuh Envelope Subtotal: 2751 Btuh Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Natural 0.37 968 1.00 6.0 249 Btuh Duct load Average sealed, R6.0, Supply(Att), Return(Att) (DLM of 0.058) 175 Btuh All Zones Sensible Subtotal All Zones 3175 Btuh HOLE HOUSE TOTALS Subtotal Sensible Heat Loss 3175 Btuh Totals for Heating Ventilation Sensible Heat Loss 0 Btuh Total Heat Loss 3175 Btuh EnergyGauge®/USRFZB v3.1 Page 1 Manual J Winter Calculations Residential Load - Component Details (continued) NAVAL CONTINUING CARE RETIREMENT FOUN®kffji0 lritle: 5808 N FLEET LANDING BLVD FLEE121 ATLANTIC BEACH, FL 32233- Building Type: User HOME FRNT DOOR WEST ORIENT' MANUAL J ADDITION ONLY 9/20/2014 EQUIPMENT 1. Geothermal Heat Pump # 41500 Btuh Key:Window types-NFRC(Requires U-Factor and Shading coefficient(SHGC)of glass as numerical values) or-Glass as'Clear'or'Tint'(Uses U-Factor and SHGC defaults) U-(Window U-Factor) * HTM-(ManualJ Heat Transfer Multiplier) Version 8 EnergyGauge@/USRFZB v3.1 Page 2 5808 N FLEET LANDING BLVD; ATLANTIC BEACH, FLORIDA 32233 EXISTING FLORIDA HEATPUMP SYSTEM EER: COP: DESIGN COOLING BTUH WHOLE HOUSE: ADDITION ONLY: AVAILABLE STATIC PRESSURE: TOTAL CFM: TOTAL EFFECTIVE LENGTH: PERFORMANCE METHOD: DUCT MATERIAL: R6 VINYL FLEX SUPPLY BRANCH DETAIL TABLE ROOM NAME COOLING CFM BRANCH SIZE LINEAR FT DUCT MATERIAL ADDITION 100 CFM 6" 20' VINYL FLEX TOTAL 100 CFM 20 LN (ft) CITY OF ATLANTIC BEACH SUPPLY TRUNK DETAIL TABLE LOCATION DESIGN BTUH TRUNK SIZE DUCT MATERIAL EXISTING EXISTING EXISTING EXISTING /-�DbCT1C�N goo GPM CONNF-cr -M 5808 N FLEET LANDING BLVD; ATLANTIC BEACH, FLORIDA 32233 MANUAL 1 FOR THE EXISTING HOUSE INCLUDING THE ADDITION Residential System Sizing Calculation Summary NAVAL CONTINUING CARE RETIREMENT FOUN®KTj�dNritle: 5808 N FLEET LANDING BLVD FLEE1882 ATLANTIC BEACH, FL 32233- WEST ORIENTATION WHOLE HOUSE W/ADDITION 9/19/2014 Location for weather data: Jacksonville, FL - Defaults: Latitude(30.5) Altitude(30 ft.) Temp Range(M) Humidit data: Interior RH 50% Outdoor wet bulb 77F Humidity difference 53 r. Winter design temperature(MJ8 99%) 32 F Summer design temperature(MJ8 99%) 93 F Winter setpoint 70 F Summer setpoint 75 F Winter temperature difference 38 F Summer temperature difference 18 F Total heating load calculation 27120 Btuh Total cooling load calculation 32489 Btuh Submitted heating capacity % of calc Btuh Submitted cooling capacity % of calc Btuh Total (Geothermal Heat Pump) 153.0 41500 Sensible (SHR = 0.74) 104.1 25160 Heat Pump +Auxiliary(0.0kW) 153.0 41500 Latent 106.3 8840 Total Geothermal Heat Pum 104.7 34000 WINTER CALCULATIONS Winter Heating Load for 1882 sqft) Ducts(10%) VUinauvvs(12%) Load component Load Window total 270 sqft 3359 Btuh Wall total 1610 sqft 6244 Btuh Ceilings(14%) Door total 48 sqft 730 Btuh Ceiling total 1950 sqft 3715 Btuh Floor total See detail report 5964 Btuh Infiltration 104 cfm 4326 Btuh Doors(3%) Duct loss 2783 Btuh Subtotal 27120 Btuh WaOs(23%) Ventilation 0 cfm 0 Btuh Fbors(22%) TOTAL HEAT LOSS 27120 Btuh SUMMER CALCULATIONS Summer Cooling Load for 1882 sqft) Load component Load Window total 270 sqft 4518 Btuh Wall total 1610 sqft 2753 Btuh Door total 48 sqft 557 Btuh Ceiling total 1950 sqft 1799 Btuh LMentlriterneg14%) Winaows(14%) Floor total 0 Btuh Infiltration 78 cfm 1537 Btuh Internal gain 11090 Btuh CelMngs(6%) Duct gain 1918 Btuh Sens. Ventilation 0 cfm 0 Btuh Blower Load 0 Btuh Total sensible gain 24172 Btuh frRGefn(34%) Latent gain(ducts) 1119 Btuh Latent gain(infiltration) 2797 Btuh JMHL(,3%) Latent gain(ventilation) 0 Btuh D—t.(9%) Latent gain(internal/occupants/other) 4400 Btuh Total latent gain 8317 Btuh TOTAL HEAT GAIN 32489 Btuh AIMILEnergter Siz t�TA LT KE 8th Edition PREP x `!�/ DATE: EnergyGauge®/USRFZB v3.1 ,I This combination qualifies for a Federal Energy CERTIFIED Efficiency Tax Credit when placed in service between Jan 1,2006 and Dec 31,2016 and used in www.ahridirectory.org GLHP or GWHP application point. Cedificateof Product Ratings AHRI Certified Reference Number: 384232 Date: 9/18/2014 tStatus: Discontinued Product:Water/Brine to Air Heat Pump Packaged Unit Model Number: ES036-ICF/HZ/VT 3 Manufacturer: FHP MANUFACTURING COMPANY Trade/Brand name: ENVIRO-SAVER Rated as follows in accordance with ANSI/AHRI/ASHRAE/ISO Standard 13256-1 for Water-to-Air and Brine-To-Air Heat Pumps and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Air Flow Rate: 1200.0/1200.0 Heating Air Flow Rate: 1200.0/1200.0 WLHP(Water-Loop Heat Pumps) Full Load Cooling Capacity(Btuh) 34000/34000 0 Cooling EER Rating(Btuh/watt) 15.20/15.20 0.00 Cooling Fluid Flow Rate(gpm) 9.00/9.00 0.00 Heating Capacity(Btuh) 41500/41500 0 Heating COP(watt/watt) 5.30/5.30 0.00 Heating Fluid Flow Rate(gpm) 9.00/9.00 0.00 GWHP(Ground-Water Heat Pumps) Cooling Capacity(Btuh) 38500/38500 0 Cooling EER Rating(Btuh/watt) 22.80/22.80 0.00 Cooling Fluid Flow Rate(gpm) 9.00/9.00 0.00 Heating Capacity(Btuh) 33500/33500 0 Heating COP(watt/watt) 4.60/4.60 0.00 Heating Fluid Flow Rate(gpm) 9.00/9.00 0.00 GLHP (Ground-Loop Heat Pumps) Cooling Capacity(Btuh) 35500135500 , 0 Cooling EER Rating(Btu h/watt) 17.60/17.60 0.00 Cooling Fluid Flow Rate(gpm) 9.00/9.00 0.00 Heating Capacity(Btuh) 26500/26500 0 Heating COP(watt/watt) 3.80/3.80 0.00 Heating Fluid Flow Rate(gpm) 9.00/9.00 0.00 Rabngs followed by an asterisk('j indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for Individual,personal and confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated; entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual, AM- personal and confidential reference. AIR-CONDITIONING<HEATING. CERTIFICATE VERIFICATION &REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahridirectory.org,click on'Verity Certificate"link we make lite better- and enter the AHRI Certified Reference Number and the date on which the certificate was Issued, which is listed above,and the Certificate No.,which is listed at bottom right. `'- --` ._ """- - 130555535360997235 ©2014 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: ystern Sizing Calculations - Summer Desi e tial Load - Whole Rause Component Details NAVAL CONTINUING CARE RETIREMENT FOUN®PffjOWitle: 5808 N FLEET LANDING BLVD FLEE1882 ATLANTIC BEACH, FL 32233- WEST ORIENTATION WHOLE HOUSE W/ADDITION 9/19/2014 Reference City: Jacksonville, FL Temperature Difference: 18.OF(MJ8 99%) Humidity difference: 53gr. Component Loads for Whop Howse w Type' Overhang Window Area(sqft) HTM Load Window Panes SHGC U InSh IS Omt Len H t Gross Shaded Unshaded Shaded Unshaded 1 2 NFRC 0.29,0.32 No No N 11.0f 1.5ft. 21.7 0.0 21.7 12 12 257 Btuh 2 2 NFRC 0.29,0.32 No No W 12.0f 1.5ft. 8.9 8.9 0.0 12 34 106 Btuh 3 2 NFRC 0.29,0.32 No No N 1.3ft. 2.2ft. 13.7 0.0 13.7 12 12 162 Btuh 4 2 NFRC 0.29,0.34 No No N 1.3ft. 0.8ft. 3.8 0.0 3.8 12 12 46 Btuh 5 2 NFRC 0-29,0.32 No No N 1.3ft. 2.2ft. 13.7 0.0 13.7 12 12 162 Btuh 6 2 NFRC 0.29,0.34 No No N 1.3ft. 0.8ft. 3.8 0.0 3.8 12 12 46 Btuh 7 2 NFRC 0.29,0.34 No No N 1.3ft. 0.8ft. 3.8 0.0 3.8 12 12 46 Btuh 8 2 NFRC 0.29,0.34 No No N 1.3ft. 0.81t. 3.8 0.0 3.8 I 12 12 46 Btuh 9 2 NFRC 0.29,0.32 No No N 1.3ft. 0.5ft. 49.0 0.0 49.0 12 12 579 Btuh 10 2 NFRC 0.29,0.32 No No N 1.3ft. 1.21t. 16.5 0.0 16.5 12 12 195 Btuh 11 2 NFRC 0.29,0.32 No No N 1.3ft. 1.2ft. 16.5 0.0 16.5 12 12 195 Btuh 12 2 NFRC 0.30,0.33 No No N 1.3ft. 2.4ft. 11.6 0.0 11.6 12 12 142 Btuh 13 2 NFRC 0.16,0.30 No No N 1.3ft. 1.Oft. 22.1 0.0 22.1 9 9 193 Btuh 14 2 NFRC 0.16,0.30 No No E 1.3ft. 1.0ft. 22.1 0.5 21.6 9 21 453 Btuh 15 2 NFRC 0.16,0.30 No No E 1.3ft. 1.0ft. 22.1 0.5 21.6 9 21 453 Btuh 16 2 NFRC 0.29,0.32 No No E 1.3ft. 2.8ft. 10.1 0.0 10.1 12 34 340 Btuh 17 2 NFRC 0.29,0.34 No No E 1.3ft. 0.5ft. 5.4 1.4 4.0 12 34 154 Btuh 18 2 NFRC 0.29,0.32 No No E 1.3ft. 2.8ft. 10.1 0.0 10.1 12 34 340 Btuh 19 2 NFRC 0.29,0.34 No No E 1.3ft. 0.5ft. 5.4 1.4 4.0 12 34 154 Btuh 20 2 NFRC 0.29,0.76 Skylight S (45deg.) 6.0 0.0 6.0 12 74 446 Btuh Window Total 270 (sqft) 4518 Btuh Walls Type U-Value R-Value Area(sqft) HTM Load Cav/Sheath 1 Frame-Steel-Adj 0.12 11.0/0.0 116.0 2.1 248 Stun 2 Frame-Steel-Ext 0.10 19.0/0.0 48.3 2.0 99 Btuh 3 Frame-Steel-Ext 0.10 19.0/0.0 50.0 2.0 102 Btuh 4 Frame-Steel-Ext 0.10 19.0/0.0 51.1 2.0 105 Btuh 5 Frame-Steel-Ext 0.10 19.0/0.0 117.5 2.0 241 Btuh 6 Frame-Steel-Ext 0.10 19.0/0.0 20.0 2.0 41 Btuh 7 Frame-Steel-Ext 0.10 19.0/0.0 55.0 2.0 113 Btuh 8 Frame-Steel-Ext 0.10 19.0/0.0 20.0 2.0 41 Btuh 9 Frame-Steel-Ext 0.10 19.0/0.0 126.9 2.0 260 Btuh 10 Frame-Steel-Ext 0.10 19.0/0.0 20.0 2.0 41 Btuh 11 Frame-Steel-Ext 0.10 19.0/0.0 68.3 2.0 140 Btuh 12 Frame-Steel-Ext 0.10 19.0/0.0 65.8 2.0 135 Btuh 13 Frame-Steel-Ext 0.10 19.0/0.0 20.0 2.0 41 Btuh 14 Frame-Steel-Ext 0.10 19.0/0.0 138.9 2.0 284 Btuh 15 Frame-Steel-Nei 0.10 19.0/0.0 660.0 1.2 795 Btuh 16 Frame-Steel-Adj 0.12 11.0/0.0 32.0 2.1 68 Btuh Wall Total 1610(sqft) 2753 Btuh Doors Type Area(sqft) HTM Load 1 Insulated-Garage 20.0 11.6 232 Btuh 2 Insulated-Exterior 20.0 11.6 232 Btuh 3 Insulated-Exterior 8.0 11.6 93 Btuh Door Total 48 (sqft) 557 Btuh Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM Load 1 Unvented Attic/Light/Tile 0.050 0.1/19.0 1761.0 0.95 1673 Btuh 2 Knee Wall/Light/Tile 0.054 0.1/19.0 68.0 0.16 11 Btuh 3 Unvented Attic/Light/Tile 0.050 0.1/19.0 121.0 0.95 115 Btuh Ceiling Total 1950 (sqft) 1799 Btuh EnergyGauge®/USRFZB 0.1 Page 1 Manual J Summer Calculations Residential Load - Component Details (continued) NAVAL CONTINUING CARE RETIREMENT FOUNIPA64 OWitle: Climate:FL_JACKSONVILLE_INTL_ARPT 5808 N FLEET LANDING BLVD FLEE1882 ATLANTIC BEACH, FL 32233- WEST ORIENTATION WHOLE HOUSE W/ADDITION 9/19/2014 Floors Type R-Value Size HTM Load 1 Slab On Grade 0.0 1761 (ft-perimeter) 0.0 0 Btuh 2 Slab On Grade 0.0 121 (ft-perimeter) 0.0 0 Btuh Floor Total 1882.0(sqft) 0 Btuh Envelope Subtotal: 9627 Btuh Infiltration Type Average ACH Volume(cuft)Wall Ratio CFM= Load Natural 0.28 16817 1 77.7 1537 Btuh Internal Occupants Btuh/occupant Appliance Load gain 3 X 230 + 10400 11090 Btuh Sensible Envelope Load: 22254 Btuh Duct load Average sealed,Supply(R6.0-Attic),Retum(R6.0-Attic) (DGM of 0.086) 1918 Btuh Sensible Load All Zones 24172 Btuh EnergyGauge®/USRFZB v3.1 Page 2 Manual J Summer Calculations Residential Load - Component Details (continued) NAVAL CONTINUING CARE RETIREMENT FOUN®Mj�@Kitle: Climate:FL_JACKSONVILLE_INTL_ARPT 5808 N FLEET LANDING BLVD FLEE1882 ATLANTIC BEACH, FL 32233- WEST ORIENTATION WHOLE HOUSE W/ADDITION 9/19/2014 WHOLE HOUSE TOTALS Sensible Envelope Load All Zones 22254 Btuh Sensible Duct Load 1918 Btuh Total Sensible Zone Loads 24172 Btuh Sensible ventilation 0 Btuh Blower 0 Btuh Whole House Total sensible gain 24172 Btuh Totals for Cooling Latent infiltration gain (for 53 gr. humidity difference) 2797 Btuh Latent ventilation gain 0 Btuh Latent duct gain 1119 Btuh Latent occupant gain (3.0 people @ 200 Btuh per person) 600 Btuh Latent other gain 3800 Btuh Latent total gain 8317 Btuh TOTAL GAIN 32489 Btuh EQUIPMENT 1. Geothermal Heat Pump # 34000 Btuh 'Key: Window types(Panes-Number and type of panes of glass) (SHGC-Shading coefficient of glass as SHGC numerical value) (U-Window LI-Factor) (InSh-Interior shading device:none(No),Blinds(B), Draperies(D)or Roller Shades(R)) - For Blinds:Assume medium color, half closed For Draperies:Assume medium weave,half closed For Roller shades:Assume translucent,half closed (IS-Insect screen:none(N). Full(F)or Half(%)) (Ornt-compass orientation) Version 8 EnergyGaugeO/USRFZB v3.1 Page 3 System Sizing Calculations - Winter Residential Load - Whole House Component Details NAVAL CONTINUING CARE RETIREMENT FOUN®kcTjt@Kitle: 5808 N FLEET LANDING BLVD FLEE1882 ATLANTIC BEACH, FL 32233- Building Type: User WEST ORIENTATION WHOLE HOUSE W/ADDITION 9/19/2014 Reference City: Jacksonville, FL (Defaults) Winter Temperature Difference: 38.0 F (MJ8 99%) Component Loads for Whole House Window Panes/Type Frame U Orientation Area s ft X HTM= Load 1 2, NFRC 0.29 Vinyl 0.32 N 21.7 12.2 264 Btuh 2 2, NFRC 0.29 Vinyl 0.32 W 8.9 12.2 109 Btuh 3 2, NFRC 0.29 Vinyl 0.32 N 13.7 12.2 167 Btuh 4 2, NFRC 0.29 Vinyl 0.34 N 3.8 12.9 49 Btuh 5 2, NFRC 0.29 Vinyl 0.32 N 13.7 12.2 167 Btuh 6 2, NFRC 0.29 Vinyl 0.34 N 3.8 12.9 49 Btuh 7 2, NFRC 0.29 Vinyl 0.34 N 3.8 12.9 49 Btuh 8 2, NFRC 0.29 Vinyl 0.34 N 3.8 12.9 49 Btuh 9 2, NFRC 0.29 Vinyl 0.32 N 49.0 12.2 596 Btuh 10 2, NFRC 0.29 Vinyl 0.32 N 16.5 12.2 201 Btuh 11 2, NFRC 0.29 Vinyl 0.32 N 16.5 12.2 201 Btuh 12 2, NFRC 0.30 Vinyl 0.33 N 11.6 12.5 146 Btuh 13 2, NFRC 0.16 Vinyl 0.30 N 22.1 11.4 252 Btuh 14 2, NFRC 0.16 Vinyl 0.30 E 22.1 11.4 252 Btuh 15 2, NFRC 0.16 Vinyl 0.30 E 22.1 11.4 252 Btuh 16 2, NFRC 0.29 Vinyl 0.32 E 10.1 12.2 123 Btuh 17 2, NFRC 0.29 Vinyl 0.34 E 5.4 12.9 70 Btuh 18 2, NFRC 0.29 Vinyl 0.32 E 10.1 12.2 123 Btuh 19 2, NFRC 0.29 Vinyl 0.34 E 5.4 12.9 70 Btuh 20 2, NFRC 0.29 Vinyl 0.76 SKY(S) 6.0 28.8 173 Btuh Window Total 270.2 s ft 3359 Btuh Walls Type Ornt. Ueff. R-Value Area X HTM= Load (Cav/Sh) 1 Frame - Steel -Adj (0.119) 11.0/0.0 116 4.51 523 Btuh 2 Frame - Steel - Ext (0.100) 19.0/0.0 48 3.82 184 Btuh 3 Frame - Steel - Ext (0.100) 19.0/0.0 50 3.82 191 Btuh 4 Frame - Steel - Ext (0.100) 19.0/0.0 51 3.82 195 Btuh 5 Frame - Steel - Ext (0.100) 19.0/0.0 118 3.82 448 Btuh 6 Frame - Steel - Ext (0.100) 19.0/0.0 20 3.82 76 Btuh 7 Frame - Steel - Ext (0.100) 19.0/0.0 55 3.82 210 Btuh 8 Frame - Steel - Ext (0.100) 19.0/0.0 20 3.82 76 Btuh 9 Frame - Steel - Ext (0.100) 19.0/0.0 127 3.82 484 Btuh 10 Frame - Steel - Ext (0.100) 19.0/0.0 20 3.82 76 Btuh 11 Frame - Steel - Ext (0.100) 19.0/0.0 68 3.82 261 Btuh 12 Frame - Steel - Ext (0.100) 19.0/0.0 66 3.82 251 Btuh 13 Frame - Steel - Ext (0.100) 19.0/0.0 20 3.82 76 Btuh 14 Frame - Steel - Ext (0.100) 19.0/0.0 139 3.82 530 Btuh 15 Frame - Steel - Nei (0.100) 19.0/0.0 660 3.82 2518 Btuh 16 Frame - Steel -Adj (0.119) 11.0/0.0 32 4.51 144 Btuh Wall Total 1610 s ft 6244 Btuh EnergyGaugeO/USRFZB v3.1 Page 1 Manual J Winter Calculations Residential Load - Component Details (continued) NAVAL CONTINUING CARE RETIREMENT FOUN®kdjt0NTitle: 5808 N FLEET LANDING BLVD FLEE1882 ATLANTIC BEACH, FL 32233- Building Type: User WEST ORIENTATION WHOLE HOUSE W/ADDITION 9/19/2014 Doors Type Storm Ueff. Area X HTM= Load 1 Insulated -Garage, n (0.400) 20 15.2 304 Btuh 2 Insulated - Exterior, n (0.400) 20 15.2 304 Btuh 3 Insulated - Exterior, n (0.400) 8 15.2 122 Btuh Door Total 48 s ft 73013tuh Ceilings Type/Color/Surface Ueff. R-Value Area X HTM= Load 1 Unvent Attic/L/Tile (0.050) 0.1/19.0 1761 1.9 3346 Btuh 2 Knee Wall/L/Tile (0.054) 0.1/19.0 68 2.0 139 Btuh 3 Unvent Attic/L/Tile (0.050) 0.1/19.0 121 1.9 230 Btuh Ceiling Total 1950 s ft 3715Btuh Floors Type Ueff. R-Value Size X HTM= Load 1 Slab On Grade (1.180) 0.0 111.0 ft(perim.) 44.8 4977 Btuh 2 Slab On Grade (1.180) 0.0 22.0 ft(perim.) 44.8 986 Btuh Floor Total 1882 s ft 5964 Btuh Envelope Subtotal: 20011 Btuh Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Natural 0.37 16817 1.00 103.6 4326 Btuh Duct load Average sealed, R6.0, Supply(Att), Return(Att) (D LM of 0.114) 2783 Btuh All Zones Sensible Subtotal All Zones 27120 Btuh HOLE HOUSE TOTALS Subtotal Sensible Heat Loss 27120 Btuh Totals for Heating Ventilation Sensible Heat Loss 0 Btuh Total Heat Loss 27120 Btuh EQUIPMENT 1. Geothermal Heat Pump # 41500 Btuh EnergyGauge@/USRFZB 0.1 Page 2 Manual J Winter Calculations Residential Load - Component Details (continued) NAVAL CONTINUING CARE RETIREMENT FOUN®kdjC0 title: 5808 N FLEET LANDING BLVD FLEE1882 ATLANTIC BEACH, FL 32233- Building Type: User WEST ORIENTATION WHOLE HOUSE W/ADDITION 9/19/2014 Key:Window types-NFRC(Requires U-Factor and Shading coefficient(SHGC)of glass as numerical values) or-Glass as'Clear'or'Tint'(Uses U-Factor and SHGC defaults) U-(Window U-Factor) HTM-(ManualJ Heat Transfer Multiplier) Version 8 EnergyGauge®/USRFZB v3.1 Page 3 ' BUILDING PERMIT APPLICATION F ILE CITY OF ATLANTIC BEACH Fly y f o!p y ' 800 Seminole Road Atlantic Beach FL 32233 Office (904) 247-5826 Fax (904) 247-5845 Job Address: —.450909i-lee f� dj ly Permit Number: 141— le flAe Legal Description Parcel# Floor Areaof SaTt. q. t Valuation of Work $ �VQc� Proposed Work heated/cooled non-heated/cooled Class of Work(circle one): New Additio> Alteratio Repair Move Demolition pool/spa window/door m Use of existing/proposed structure(s) (circle one): Comercial Residentia If an existing structure, is a fire sprinkler system installed? (Circle one): o N/A Florida Product Approval# FL ';3©. For multiple products use product approval orm Describe in detail the type of work to be performed: r Property Owner Information: Name:NCCRF dba Fleet Landing Address: 1 Fleet Landing Blvd City Atlantic Beach State FL_Zip 32233 Phone 904-246-9900 xt 431 E-Mail or Fax#(Optional)jholder@fleetlanding.com Contractor Information: Company Name:NCCRF dba Fleet Landing Qualifying Agent: Jason Holder Address:I Fleet Landing Blvd City Atlantic Beach _State FL Zip 32233 Office Phone 904-246-9900 xt 431 Job Site/Contact Number 904-219-4002 Fax# State Certification/Registration# CBC 1254586 Architect Name& Phone# Engineer's Name& Phone# Fee Simple Title Holder Name and Address Bonding Company Name and Address Mortgage Lender Name and Address Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards of all laws regulating construction in this jurisdiction. This permit becomes null and void rf work is not conunenced within six(6)months, or if construction or work is suspended or abandoned for a period of six 6)nnonths at any time after work is commenced. I understand that separate permits must be secured for Electricar Work, Plumbing, Signs, Wells, Pools, urnaces, Boilers,Heaters, Tanks and Air Conditioners,etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. I hereby certify that I have read and examined this application The granting of a permit does not plication and know the same to be true and correct. All provisions of laws and ordinances governing this type o work will be complied with whether specified herein opresume to give authority to violate or cancel the Provisions of any other federal,state, or local law regul ting construction or the performance of construction. Signature of Owner Signature of Contractor Print Name Jason HolderPrint Name Jason Hol er ......................................................................................................................................... ......................................................................................................................................... Sworn to and subscribed before me Sworn to and subscribed before me this 1 Day of 4r�v A_A " 20 this Aj—Day of 20 Notary Public vN SHARI R QUEST r 04vP SHARI R QUE T __ `"° `s �P,, d 01.26.10 � MY COMMISSION#FFOB8247 •, MY COMMISSION#FF068'I� . : , ; EXPIRES November 4.2017 EXPIRES November 4.2017 (407)398-0153 FloridallotaryService.com (407)398-0153 Floridallota Servioe.com Nasp~....r a-1 City of Atlantic Beach APPLICATION NUMBER i Building Department (To be assigned by the Building Department.) 800 Seminole Road J �} Atlantic Beach, Florida ? "3-5445 Phone(904)247-5826 (904)247-5845 City web-site: http://ww. b.us Date routed: 7 APPLICATIOt REVIEW AND TRACKING FORM Property Address: J2epartment review required Yes No Building Applicant: Planning &Zoning ^ / n Tree Administrator Project: �� C: `� s GI C Public Works Public Utilities Public Safety Fire Services Review fee $ Dept Signature CONTRACTOR EMAIL i DRESS CONTRACTOR CONTAt # ;;.2 /q - �92_ n �e5,4 APPLICATION STATUS Reviewing Department First Review: ❑Approved. ❑Denied. (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: Date: TREE ADMIN. Second Re\ ❑Approved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review [—]Approved as revised. []Denied. Comments: Reviewed by: Date: REVISED 09252014 FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name. FLEE121 Builder Name: Street: 5808 N FLEET LANDING BLVD Permit Office: CITY OF ATLANrtIC City,State;Zip: ATLANTIC BEACH , FL,32233- Permit Number: F Owner: NAVAL CONTINUING CARE RETIREMENT FOUNDA Jurisdiction: 261100 _ nT Design Location: FL,Jacksonville ---- ea.-,vRa .*mow;.-:+cti.�iw 1. New construction or existing Addition 9. Wall Types(220.0 sqft.) Insulation Area 2. Single family or multiple family Multi-family a. Frame-Steel,Exterior R=19.0 220.00 ft2 b. N/A R= ft2 3. Number of units.. if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms(Bedrms In Addition) 0(0) d. N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (121.0 sqft.) Insulation Area a.Roof Deck(Unvented) R=19.0 121.00 ft2 6. Conditioned floor area above grade(ft2) 121 b. N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(77.9 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Garage 6 24.2 a. U-Factor: Dbl,U=0.30 66.25 ft2 SHGC: SHGC=0.16 b. U-Factor: Dbl, U=0.33 11.63 ft2 12.Cooling systems kBtu/hr Efficiency a.Geothermal Heat Pump 34.0 EER:1520 SHGC: SHGC=0.30 c. U-Factor: N/A ft2 SHGC 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Geothermal Heat Pump 41.5 COP:5.30 SHGC: Area Weighted Average Overhang Depth: 1.333 ft. Area Weighted Average SHGC: 0.181 14. Hot water systems None required a. Cap:N/A 8. Floor Types (121.0 sqft.) Insulation Area EF:0.000 a.Slab-On-Grade Edge Insulation R=0.0 121.00 ft2 b. Conservation features b. N/A R= ft2 Heat Recovery Unit c. N/A R= ft2 15.Credits CF Total Proposed Modified Loads: 2.00 PASS Glass/Floor Area: 0.644 Total Standard Reference Loads: 4.99 SS i 1 hereby certify that the plans and specifications covered by Review of the plans and �c.TKE STq�� this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance WENDY AM N��LIKE with the Florida Energy Code. PREPARED BY: 1coliance Before construction is completedDATE: this building will be inspected forcompliance with Section 553.908I hereby certify that this building, as designed, is iFlorida Statutes. with the Florida Energy Code. C�[3 WE � OWNER/AGENT: -__ _ BUILDING OFFICIAL: DATE: __-- - - - --- __ DATE: Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist � M � � H TC SEP 2 2 014 By 9/20/2014 11:23 AM EnergyGaugeO USA-FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5 TABLE 402.4.2 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: FLEE121 Builder Name: Street: 5808 N FLEET LANDING BLVD Permit Office: CITY OF ATLANTIC BEACH City,State,Zip: ATLANTIC BEACH , FL,32233- Permit Number. Owner: NAVAL CONTINUING CARE RETIREMENT FOUNDA Jurisdiction: 261100 Design Location: FL.Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier Exterior thermal envelope insulation for framed walls is installed in substantial contact and continuous alignment with building envelope air barrier. Breaks or joints in the air barrier are filled or repaired. Air-permeable insulation is not used as a sealing material. Air-perm able insulation is inside of an air barrier. Ceiling/attic Air barrier in any dropped ceiling/soffit is substantially aligned with insulation and any gaps are sealed. Attic access (except unvented attic), knee wall door, or drop down stair is sealed. Walls Corners and headers are insulated. Junction of foundation and sill plate is sealed. Windows and doors Space between window/door jambs and framing is sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including Insulation is installed to maintain permanent contact with underside above-garage and of subfloor decking. cantilevered floors) Crawl space walls Insulation is permanently attached to walls. Exposed earth in unvented crawl spaces is covered with Class I Shafts, penetrations Duct shafts, utility penetrations, knee walls and flue shafts opening to exterior or unconditioned space are sealed. Narrow cavities Batts in narrow cavities are cut to fit, or narrow cavities are filled by sprayed/blown insulation. Garage separation Air sealing is provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures are air tight, IC rated, and sealed to drywall. Exception—fixtures in conditioned space. Plumbing and wiring Insulation is placed between outside and pipes. Batt insulation is cut to fit around wiring and plumbing, or sprayed/blown insulation Shower/tub on exterior wall Showers and tubs on exterior walls have insulation and an air barrier separating them from the exterior wall. Electrical/phone box on Air barrier extends behind boxes or air sealed-type boxes are installed. Common wall Air barrier is installed in common wall between dwelling units. HVAC register boots HVAC register boots that penetrate building envelope are sealed to subfloor or drVwall. Fireplace Fireplace walls include an air barrier. EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software PROJECT Title: FLEE121 Bedrooms: 0 Address Type: Street Address Building Type: User Conditioned Area: 121 Lot# Owner: NAVAL CONTINUING CARE Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 5808 N FLEET LANDIN Permit Office: CITY OF ATLANTIC BEACH Cross Ventilation: No County: Duval Jurisdiction: 261100 Whole House Fan: No City,State,Zip: ATLANTIC BEACH, Family Type: Multi-family FL, 32233- New/Existing: Addition Comment: HOME FRNT DOOR WEST ORIENT MANUAL J ADDITION ONLY CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL—JACKSONVILLE—INT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Block1 121 968 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 ADDITION 121 968 No 0 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio ADDITION 22 ft 0 121 ft2 -_� 0.2 0.2 0.6 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Barrel the 135 ft2 0 ft2 Light 0.65 No 0.9 No 19 26.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Unvented 0 121 ft2 N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic(Unvented) ADDITION 0.1 121 ft2 0.11 Wood 9/20/2014 11:23 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below V;a Ornt To Wall Type 0 _ 1 N Exterior Frame--Steel ADDITION 19 11 0 10 0 110.0 ft2 0 0.23 0.29 0 2 E Exterior Frame-Steel ADDITION 19 11 0 10 0 110.0 ft2 0 0.23 0.29 0 DOORS # Ornt Door Type Space Storms U-Value Ft Width In Ft eighttn Area 1 S Insulated ADDITION None .4 1 2.4 6 8 8 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 0.33 0.3 11.6 ft2 1 ft 4 in 2 ft 5 in None None 2 N 1 Vinyl Low-E Double Yes 0.3 0.16 22.1 ft2 1 ft 4 in 1 ft 0 in None None 3 E 2 Vinyl Low-E Double Yes 0.3 0.16 22.1 ft2 1 ft 4 in 1 ft 0 in None None 4 E 2 Vinyl Low-E Double Yes 0.3 0.16 22.1 ft2 1 ft 4 in 1 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 528 ft2 528 ft2 53 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess .0003 95.2 5.23 9.83 .231 5.9018 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Geothermal Heat Pump Water Source-Closed Loop COP:5.3 41.5 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Geothermal Heat Pump Water Source-Closed Loop EER:15.2 34 kBtu/hr 1020 cfm 0.74 1 sys#1 SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 9/20/2014 11:23 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5 DUCTS / ----Supply-- —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 24.2 ft2 Attic 6.05 ft2 Default Leakage Garage (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling [[X]Jan Feb (X]Mar X]Apr X]May [[X Jun X]Jul X Aug [[X]Sep [[X]]Oct [[X)Nov X]Dec Ventingg XJan jXj XFeb [X]Mar lX]Appr lX]May [X�Jun tX]Jul �J Aug [X]Sep [X]Oct [X]Nov X]Dec Ventin XX]]Jan X Feb [X]Mar [X]Apr [X]May [[XX]]Jun [X]Jul [X]Aug [[X]Sep [[X]]Oct [[XX]]Nov X]Dec Thermostat Schedule: BABM2008 Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 Cooling(WEH) AM 75 75 75 75 75 75 75 75 75 75 75 75 PM 75 75 75 75 75 75 75 75 75 75 75 75 Heating(WD) AM 70 70 70 70 70 70 70 70 70 70 70 70 PM 70 70 70 70 70 70 70 70 70 70 70 70 Heating(WEH) AM 70 70 70 70 70 70 70 70 70 70 70 70 PM 70 70 70 70 70 70 70 70 70 70 70 70 9/20/2014 11:23 AM EnergyGaugeO USA-FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: 5808 N FLEET LANDING BLVD PERMIT#: ATLANTIC BEACH, FL, 32233- MANDATORY REQUIREMENTS SUMMARY-See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed,weatherstripped or otherwise sealed. Recessed lighting IC-rated as meeting ASTM E 283. Windows and doors=0.30 cfm/sq.ft.Testing or visual inspection required. Fireplaces:gasketed doors&outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat& 403.1 At least one thermostat shall be provided for each separate heating controls and cooling system. Where forced-air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers,filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and / sealed in accordance with Section 503.2.7.2 of this code. v 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric)or shutoff(gas). Circulating system pipes insulated to= R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics,crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower(HP)of= 1 &Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor-retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site-recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82%after 4/16/13). Heat pump pool heaters minimum COP=4.0. Cooling/heating 403.6 Sizing calculation performed &attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or / variable capacity system. Electric heat>10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-1 9/20/2014 11:23 AM 9Y 9 Ener Gau eO USA-RaRes2010 Section 405.4.1 compliant Software Page 5 of 5