1601 Atlantic Beach Dr Revisions 2014 TOR `Brothers " FILE COPY
America's Luxury Home Builder°
September 24, 2014 "
Mr. Mike Jones
City of Atlantic Beach L� 11 Ll I
800 Seminole Road SE 25 211
Atlantic Beach, FL 32233 L�
By
Dear Mr.Jon :
Enclosed are plan revisions for our home we are building as our model home for
Permit 14-1245 at 1601 Atlantic Beach Drive.
1-wanted,to,highlight the revisions that we made on thep lans:
1. The trusses were revised to add more detail to rear roof line. The view
from the golf course showed too much roof with�At any architecture
detail. Please see the structural engineering SK-2/ SK-3 (1), architectural
plans (113) and revised truss engineering books (1C). The truss revisions
did not alter the foundation plan structurally. Please see the attached
letter from the engineer. Additionally, we made changes to the size of
bedroom 4 and some other minor revisions.
2. This home will be our model home. We will be using the garage as the
area that we will be doing presentation, etc. It will be converted back to a
garage when we close down the model home. Our sales office will be in
the front bedroom of the home. Due to this, we need to use the closet
adjacent to the garage to access the bedroom area. Please see the attached
sketch from the engineer labeled SK-4 for framing (2) and SK-5 for the
foundation (2D) for the detail of the slab recess we need to create. Also,
please see the revised energy calculations (213) for heating and cooling this
area. We will be adding a zone to cool this area. I have included the arch.
plan for the temporary sales office as a separate plan set (2C) for your use.
3. Lastly, please find SK-7 (3) that is clarifying the framing detail of the PSL/
Girder truss AG and the PSL column.
I would be happy to come in and review these with you if you like. Please give
me a call if so at 904 386-6472.
Thank you for your time and help with this.
,incer ,
eve en
Division Vice President
New York Stock Exchange • Symbol TOL
Florida North Division
160 Cape May Avenue, Ponte Vedra, FL 32081 • (904) 217-3852 • Fax (904) 460-2683
tollbrothers.com
i _ x
I
8" WIDE MONO
FOOTING, SEE
i 5 1/SK-1
5 I I 51.0 I 2—#5x30" DOWE�
EPDXIED 6" MINI s
51.0 I I 3'-10'1 i I 6 0„ INT S EMWA a:
o � I
M r
`CS
F2.0 r 5 1'1 I ,, `G�'`O•\••�A�s•w.�Q�'�4
WOOD StAIRS L
11'-2" (POST) BY BU LDER I •
N.
NO. 1 •;2=_
CONCRETE STAIRS
11 —6 L— BY BUILDER.
OF
. �
PARTIAL FOUNDATION PLAN 4'Ss/ONAIEo�,�``'',,
' FILE C #3 DOWAL BAR WITH 12"
90' HOOK 0 16" O.C.
.._ 8" 8" EPDXIED 4" MIN
EXISTING I EXISTING
S&W SLAB ONGRADE • • SLAB ON
� GRADE
SL�L CJ • 4„
• • #4 HORIZONTAL REBAR
#4 DOWAL BAR WITH 12"
90' HOOK @ 16" O.C.
1 SECTION
Lou Ponti3o and SK—
PROJECT LOT 1 ATLANTIC BEACH AMB.
Associates , Inc . BUILDER TOLLBROTHERS
-�FA-1420 Osceola Avenue
lax. [leach.Florida 32250 106 NO. SHT.NO.Ph.242-0908 Fax.241-9557 TOLL-l4-00372 S K- 5
FL:CA#8344 SC:CA#3579 DATE 09.23.14
Citi f
6 +�/ r2J2 yT � N 1
N
AM N
A24 (2)2x6 BELOW POST
ABOVE. STRAP POST \
x _J\
TOGETHER SHED ROOF, � a
WITH (2)CS16. 2x6 FULL HEIGHT I Z
PROVIDE SOLID BLOCKING °0 SEE 12fS.02 3 Go
WALL N N
WITHIN FLOOR SYSTEM.
2 ABO
)2x6 SPF '
2 � \ '
POST. - k a` STRAP HEADER
\ �- PER 7/SO 1
PLY 9.25" VL-'2
(3)2x6 BELOW POST
o _
N POST
ABOVE. STRAP N I
9 TOGETHER WITH ( ) N
2 CS16.
PROVIDE SOLID BLOCKING POST TO MATCH POST I
WITHIN FLQQR_SYSTEM.
FROM ABOVE. STRAP POST I _
TOGETHER WITH (2)CS16.
PROVIDE SOLID BLOCKING I 10,
POST F WITHIN FLOOR SYSTEM. I p I
ROM-ABOVE. I So.z
STRAP TO HEADER
WITH m N
(2)CS18. PROVIDE SOLID I a N vo
PARTIAL 2ND FLOOR FRAMING PLAN
pNER
...........Sq w,I
0. 7
61
FILE Copy ' ,-
. � O F
F10 P'eui 3-
t d
L P Lou P o n t i 3 o a n d PROJECT LOT l ATLANTIC BEACH AMB.
Associates , Inc . BUILDER
420 Osceola Avenue TOLL B ROTH E RS
lax. Beach,Florida 32250 JOB No.
& A Ph.242-0908 Fax.241-9557 TOLL-14-00372 SHT.No.
FL:CA#8344 SC:CA#3579 DATE
09.24.14 S K"4
FORM 405-10
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: CATALINA 4342 Sales Builder Name: Toll Brothers
Street Lot 1 Atlantic Beach Country Club Permit Office: Duval Z
City,State,Zip: Jacksonville,FL . Permit Number: I f- 1 7
Owner: Toll Brothers Jurisdiction: 261300
Design Location: FL,Jacksonville
1. New construction or existing New(From Plans) 9. Wall Types(4425.8 sgft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood, Exterior R=19.0 3953.30 ft'
b. Interior Frame-Wood,Interior R=19.0 472.50 ft'
3. Number of units,if multiple family 1 c. N/A R= ft'
4. Number of Bedrooms 5 d. N/A R= ft2
5. Is this a worst case? No 10.Ceiling Types (3840.0 sgft.) Insulation Area
a.Under Attic(Vented) R=38.0 3540.00 ft:
6. Conditioned floor area above grade(ft') 5708 b.Knee Wall(Vented) R=19.0 300.00 ft2
Conditioned floor area below grade(ft') 0 c.N/A R= ft'
11.Ducts R ft=
7. Windows(673.8 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 516
a. U-Factor: Dbl,U=0.34 673.83 ft' b.Sup: Attic,Ret:Attic,AH:Attic 6 380
SHGC: SHGC=0.27
b. U-Factor: N/A ft' Q.Cooling systems kBtu/hr Efficiency
SHGC: a.Central Unit 42.0 SEER:14.00
b.Central Unit 24.0 SEER:14.00
c. U-Factor: NIA ft'
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft' a.Electric Heat Pump 42.0 HSPF:8.00
SHGC: b.Electric Heat Pump 24.0 HSPF:8.00
Area Weighted Average Overhang Depth: 1986 ft.
Area Weighted Average SHGC: 0.270 14.Hot water systems
a.Natural Gas Tankless Cap' 1 gallons
8. Floor Types (5025.0 sqft.) Insulation Area
EF:0.590
a.Slab-On-Grade Edge Insulation R=0.0 3540.00 ft' b. Conservation features
b.Floor Over Other Space R=0.0 1485.00 ft' None
c.NIA R= ft' 15.Credits Pstat
Glass/Floor Area: 0.118 Total Proposed Modified Loads: 59.01 PASS
Total Standard Reference Loads: 101.33
I hereby certify that the plans and specifications covered by Review of the plans and NTV q',,�
this calculation are in compliance with the Florida Energy specifications covered by this
Code. s� /f calculation indicates compliance 2
� // with the Florida Energy Code. I-�` ,. '`.:, ':• .?;On i
PREPARED 3Y: / 1jj '�/� r� Before construction is completed %'-
DATE: >? s/ this building will be inspected for a•
compliance with Section 553.908 .
I hereby certify that this building, a ned,is in compliance Florida Statutes. � �
with the Florida Energy Code. D wi",
OWNER/AGENT: s! BUILDING OFFICIAL:
DATE: Q DATE:
- Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist
t'
P-evi-Src r) �r U S S n•� asR f_Q 5-{ S�r�(-e Gt r ct
FILE COPY p 9&44a4ton area; motley hoe-n-4-
8/27/2014 10:27 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page t of 6
PROJECT
Title: CATALINA 4342 Sales Bedrooms: 5 Address Type: Street Address
Building Type: User Conditioned Area: 5708 Lot#
Owner: Toll Brothers Total Stories: 2 Block/SubDivision:
#of Units: 1 Worst Case: No PlatBook:
Builder Name: Toll Brothers Rotate Angle: 0 Street: Lot 1 Atlantic Beach Co
Permit Office: Duval Cross Ventilation: No County: Duval
Jurisdiction: 261300 Whole House Fan: No City,State,Zip: Jacksonville
Family Type: Single-family FL
New/Existing: New(From Plans)
Comment:
CLIMATE
IECC Design Temp Int Design Temp Heating Design Daily Temp
v/ Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
!' FL,Jacksonville FL_JACKSONVILLE_INT 2 32 93 70 75 1281 49 Medium
BLOCKS
Number Name Area Volume
1 Blockl 3540 35400
2 Block2 2168 20195
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated
1 1st Floor 3540 35400 Yes 3 2 1 Yes Yes Yes
2 2nd Floor 1485 13365 No 3 3 1 Yes Yes Yes
3 Sales 683 6830 No 2 0 1 Yes Yes Yes
FLOORS
F_,Zvislab-On-Grade
Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
Edge Insulatio 1st Floor 39.5 It 0 2857 ft' 0 0 1
2 Floor Over Other Space 2nd Floor __-- -_-- 994 ft' 0 0 0 1
3 Floor Over Other Space 2nd Floor ---- ___- 491 ft' 0 0 0 1
4 Slab-On-Grade Edge Insulatio Sales 55 R 0 683 ft' -_-- 0 0 1
ROOF
Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
# Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Gable or Shed Composition shingles 3959 ft' 886 ft' Medium 0.7 N 0.9 No 0 26.6
/ ATTIC
V / # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
✓ 1 Full attic Vented 300 3540 ft' N N
8/2712014 10:27 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6
CEILING
# Ceiling Type Space R-Value Area Framing Frac Truss Type
1 Under Attic(Vented) 1st Floor 38 2055 ft' 0.11 Wood
2 Under Attic(Vented) 2nd Floor 38 1485 ft' 0.11 Wood
3 Knee Wall(Vented) 2nd Floor 19 300 ft' 011 Wood
WALLS
Adjacent SCavity Width Height Sheathing Framing Solar Below
pace
# Ornt To Wait Type R-Value Ft In Ft In Area R-Value Fraction Absor. Grade%
21 SW Exterior Frame-Wood 1st Floor 19 8 9 10 0 87.5 ft' 0 0.25 0.8 0
2 S Exterior Frame-Wood 1 st Floor 19 40 6 12 0 486.0 ft' 0 0.25 0.8 0
3 SE Exterior Frame-Wood 1 st Floor 19 3 6 12 0 42.0 ft' 0 0.25 0.8 0
4 E Exterior Frame-Wood 1 st Floor 19 49 0 12 0 588.0 ft' 0 0.25 0.8 0
5 NE Exterior Frame-Wood 1 st Floor 19 3 6 12 0 42.0 ft' 0 0.25 0.8 0
6 N Exterior Frame-Wood 1 st Floor 19 33 5 12 0 401,0 ft' 0 0.25 0.8 0
7 W Exterior Frame-Wood 1st Floor 19 20 1 10 0 200.8 ft' 0 0.25 0.8 0
8 SW Exterior Frame-Wood 2nd Floor 19 8 9 9 0 78.8 ft' 0 0.25 0.8 0
9 S Exterior Frame-Wood 2nd Floor 19 40 9 9 0 366.8 ft' 0 0.25 0.8 0
10 E Exterior Frame-Wood 2nd Floor 19 39 9 9 0 357.8 ft' 0 0.25 0.8 0
11 N Exterior Frame-Wood 2nd Floor 19 46 9 9 0 420.8 ft' 0 0.25 0.8 0
12 W Exterior Frame-Wood 2nd Floor 19 40 9 9 0 366.8 ft' 0 0.25 0.8 0
13 NW Exterior Frame-Wood 2nd Floor 19 4 9 9 0 42.8 ft' 0 0.25 0.8 0
14 S 1st Floor Interior Frame-Wood Sales 19 22 9 9 0 204.8 ft' 0 0.25 0.8 0
15 E 1st Floor Interior Frame-Wood Sales 19 29 9 9 0 267.8 ft' 0 0.25 0.8 0
16 N Exterior Frame-Wood Sales 19 22 9 9 0 204.8 ft' 0 0.25 0.8 0
17 W Exterior Frame-Wood Sales 19 29 9 9 0 267.8 ft' 0 0.25 0.8 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 SW Wood 1st Floor None .6 3 8 24 ft'
WINDOWS
Orientation shown is the entered,Proposed orientation.
Wall Overhang
V/ # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 SW 1 Vinyl Low-E Double Yes 0.34 0.27 20.0 ft' 1 ft 4 in 1 ft 0 in None Interior 5
2 SW 1 Vinyl Low-E Double Yes 0.34 0.27 30.0 ft' 1 It 4 in 1 ft 0 in None Interior 5
3 SE 3 Vinyl Low-E Double Yes 0.34 0.27 15.0 ft' 7 ft 4 in 1 ft 0 in None Interior 5
4 E 4 Metal Low-E Double Yes 0,34 0.27 128.0 ft' 9 ft 0 in 1 ft 0 in None Interior 5
5 E 4 Vinyl Low-E Double Yes 0.34 0.27 30.0 ft' 4 ft 7 in 1 ft 0 in None interior 5
6 E 4 Vinyl Low-E Double Yes 0.34 0.27 45.0 ft' 12 ft 1 in 1 ft 0 in None Interior 5
7 NE 5 Vinyl Low-E Double Yes 0.34 0.27 15.0 ft' 7 ft 4 in 1 ft 0 in None Interior 5
8 N 6 Vinyl Low-E Double Yes 0.34 0,27 30.0 ft' 1 ft 4 in 11 ft 0 in None Interior 5
9 N 6 Vinyl Low-E Double Yes 0.34 0.27 12.5 ft' 1 ft 4 in 11 ft 0 in None Interior 5
10 W 7 Vinyl Low-E Double Yes 0.34 0.27 15.0 ft' 1 ft4 in 1 ft 0 in None Interior 5
11 N 6 Vinyl Low-E Double Yes 0.34 0.27 10-0 ft' 1 ft 4 in 11 ft 0 in None Interior 5
8/2712014 10:27 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6
WINDOWS
Orientation shown is the entered.Proposed orientation.
Wall Overhang
-V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
12 E 4 Vinyl Low-E Double Yes 0.34 0.27 15.0 ft' 4 ft 4 in 1 ft 0 in None Interior 5
13 W 7 Vinyl Low-E Double Yes 0.34 0.27 30.0 ft' 1 ft 4 in 1 ft 0 in None Interior 5
14 SW 8 Vinyl Low-E Double Yes 0.34 0.27 15.0 ft' 1 ft 4 in 1 ft 0 in None Interior 5
15 N 11 Vinyl low-E Double Yes 0.34 0.27 60.0 ft' 1 ft 4 in 1 ft 0 in None Interior 5
16 N 11 Vinyl Low-E Double Yes 0.34 0.27 9.0 ft' 1 ft 4 in 1 ft 0 in None Interior 5
17 W 12 Vinyl Low-E Double Yes 0.34 0.27 30.0 ft' 1 ft 4 in 1 ft0 in None Interior 5
18 W 12 Vinyl Low-E Double Yes 0.34 0.27 8.3 ft' 1 ft 4 in 1 ft 0 in None Interior 5
19 W 12 Metal Low-E Double Yes 0.34 0.27 33.3 ft' 1 ft 4 in 1 ft 0 in None Interior 5
20 S 9 Vinyl Low-E Double Yes 0.34 0.27 15,0 ft' 1 ft 4 in 1 ft 0 in None Interior 5
21 E 10 Vinyl Low-E Double Yes 0.34 0.27 23.3 ft' 1 ft 4 in 1 ft 0 in None Interior 5
22 S 2 Vinyl Low-E Double Yes 0.34 0.27 16.0 ft' t ft 4 in 1 ft 0 in None Interior 5
23 NW 13 Vinyl Low-E Double Yes 0.34 0.27 12.0 ft2 1 ft 4 in 1 ft 0 in None Interior 5
24 W 17 Vinyl Low-E Double Yes 0.34 0.27 24.0 ft' 1 ft 4 in 1 ft 0 in None Interior 5
25 N 16 Vinyl Low-E Double Yes 0.34 0.27 24.0 W 1 ft 4 in 1 ft 0 in None Interior 5
26 W 17 Vinyl Low-E Double Yes 0.34 0.27 8.3 ft' 1 ft 4 in 1 ft 0 in None Interior 5
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Best Guess .0003 4491.7 246.59 463.74 .2844 4.8475
HEATING SYSTEM
V # System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump None HSPF:8 42 kBtu/hr 1 sys#1
2 Electric Heat Pump None HSPF:8 24 kBtu/hr 2 sys#2
COOLING SYSTEM
V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit Split SEER: 14 42 kBtu/hr 1260 cfm 0.700000 1 5ys#1
2 Central Unit None SEER: 14 24 kBtu/hr 720 cfm 0.7 2 sys#2
HOT WATER SYSTEM
Y # System Type SubType Location EF Cap Use SetPnt Conservation
1 Natural Gas Tankless Exterior 0.59 1 gal 60.9 gal 120 deg None
8/27/2014 10:27 AM EnergyGaugeO USA-FlaRes2010 Section 405.4,1 Compliant Software Page 4 of 6
FSEC SOLAR HOT WATER SYSTEM
an Name Collector Storage
Cert # Company y System Model# Collector Model# Area Volume FEF
--jZ None None
ft'
DUCTS
/
---Supply-- ----Return---- Air CFM 25 CFM25 HVAC#
# Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 516 ft' Attic 210 ft' Default Leakage Attic (Default) (Default) 1 1
2 Attic 6 380 ft' Attic 259 ft' Default Leakage Attic (Default) (Default) 2 2
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Cooling Jan Feb Mar A r Ma rj Jun X Ju X Au X Se Oct Nov Dec
Venting Jan Feb lx�Mar �X�Apr May Jun Jul Aug Sep �C�Oct X�Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
8/27/201410:27 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: Lot 1 Atlantic Beach Country Club
Jacksonville, FL, PERMIT#:
MANDATORY REQUIREMENTS SUMMARY-See individual code sections for full details.
COMPONENT SECTION
i SUMMARY OF REQUIREMEN7(S}
Air leakage 402.4 CHECK
To be caulked,Basketed,weatherstripped or otherwise sealed.
Recessed lighting IC-rated as meeting ASTM E 283. Windows and
doors=0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces:
gasketed doors&outdoor combustion air. Must complete envelope
leakage report or visually verify Table 402.4.2.
Thermostat& 403.1
At least one thermostat shall be provided for each separate heating and
controls cooling system. Where forced-air furnace is primary system,
Programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts 403.2.2
Alf ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3 Building framing cavities shall not be used as supply ducts.
Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies
Table 403.4.3.2. Provide switch or clearly marked circuit breaker
in
(electric)or shutoff(gas). Circulating system pipes insulated to= R-2
+accessible manual OFF switch.
Mechanical ! 403.5 �
Hames designed to operate at positive pressure or with mechanical
ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawispaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools 403.9 Poot pumps and pool Pump&Spas HP shall have the capability of Operating With
at two ormoremore speeds.rsepower )Sof
pas1
and heated pools must have vapor-retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70%of heat from
site-recovered energy. Off/timer switch required. Gas heaters minimum 1'
thermal efficiency=78% (82%after 4/16/13). Heat pump pool heaters
minimum COP=4.0.
Cooling/heating 403.6 Sizing calculation performed&attached. Minimum efficiencies per
equipment Tables 503,2.3. Equipment efficiency verification required. Special
occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat>10kW must be divided into two
or more stages.
Ceilings/knee walls 405.2.1
R-19 space permitting.
8/27/2014 10:27 AM EnergyGaugee USA-FlaRes2010 section 405.4.1 Compliant software
Page 6 of 6
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 58
The lower the EnergyPerformance Index, the more efficient the home.
Lot 1 Atlantic Beach Country Club, Jacksonville, FL,
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a. Frame-Wood,Exterior R=19.0 3953.30 ft'
b.Interior Frame-Wood, Interior R=19.0 472.50 ft'
3. Number of units,if multiple family 1 c.N/A R= ft'
4. Number of Bedrooms 5 d.NIA R= ft'
10.Ceiling Types Insulation Area
5. Is this a worst case? No a.Under Attic(Vented) R=38.0 3540.00 ft'
6. Conditioned floor area(ft) 5708 b.Knee Wall(Vented) R=19.0 300.00 ft'
7. Windows" Description Area c.NIA R= ft'
11.Ducts R ft'
a. U-Factor. Dbl,U=0.34 673.83 ft' a.Sup:Attic,Ret:Attic,AH:Attic 6 516
SHGC: SHGC=0.27 b.Sup: Attic,Ret:Attic,AH:Attic 6 380
b. U-Factor: NIA ft'
SHGC: 12.Cooling systems kBtulhr Efficiency
c. U-Factor: NIA ft' a.Central Unit 42.0 SEER:14.00
SHGC: b.Central Unit 24.0 SEER:14.00
d. U-Factor: NIA ft2 13.Heating systems kBtu/hr Efficiency
SHGC: a.Electric Heat Pump 42.0 HSPF 8.00
Area Weighted Average Overhang Depth: 3.986 ft. b.Electric Heat Pump 24.0 HSPF:8.00
Area Weighted Average SHGC: 0.270
8. Floor Types insulation Area 14.Hot water systems Cap: 1 gallons
a.Slab-On-Grade Edge Insulation R=0.0 3540.00 W a.Natural Gas EF:0.59
b.Floor Over Other Space R=0.0 1485.00 ft'
c.N/A R= ft2 b. Conservation features
None
15,Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building F-�tw srgT
Construction through the above energy saving features which will be installed (or exceeded) �o,. .� �,.,,a��F0
in this home before final inspection. therwise, a new EPL Display Card will be completed y``3', ; � .,
based on installed Code corn atures.
',,,1 � ;
Builder Signature: Date: 8/8�r u c S;a
Address of New Home: /66/ o-fj�G Be All Pt. City/FL Zip: 1fr4V L,B /
R 322?3
*Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient
mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation,contact the Florida Building Commission's support
staff.
**Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software
A ---
TABLE 402.4.2
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: CATALINA 4342 Sales Builder Name: Toll Brothers
Street: Lot 1 Atlantic Beach Country Club Permit Office: Duval
City,State,Zip: Jacksonville,FL, Permit Number:
Owner: Toll Brothers Jurisdiction: 281300
Design Location: FL,Jacksonville
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier Exterior thermal envelope insulation for framed walls is installed in
substantial contact and continuous alignment with building envelope
air barrier.
Breaks or joints in the air barrier are filled or repaired.
Air-permeable insulation is not used as a sealing material. �}
Air-permeable insulation is inside of an air barrier.
Ceiling/attic Air barrier in any dropped ceiling/soffit is substantially aligned with
insulation and any gaps are sealed.
Attic access (except unvented attic), knee wall door, or drop down
stair is sealed.
Walls Corners and headers are insulated.
Junction of foundation and sill plate is sealed.
Windows and doors Space between window/door jambs and framing is sealed.
Rim joists Rim joists are insulated and include an air barrier.
Floors (including Insulation is installed to maintain permanent contact with underside
above-garage and cantilevered of subfloor decking.
floors) Air barrier is installed at any exposed edge of insulation.
Crawl space walls Insulation is permanently attached to walls.
Exposed earth in unvented crawl spaces is covered with Class I
vapor retarder with overlapping joints taped. �-
Shafts, penetrations Duct shafts, utility penetrations, knee walls and flue shafts opening
to exterior or unconditioned space are sealed.
Narrow cavities Batts in narrow cavities are cut to fit, or narrow cavities are filled by
sprayed/blown insulation.
Garage separation Air sealing is provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures are air tight, IC rated, and sealed to drywall.
Exception—fixtures in conditioned space.
Plumbing and wiring Insulation is•placed between outside and pipes. Batt insulation is cut
to fit around wiring and plumbing,or sprayed/blown insulation
extends behind i in and wirin .
Shower/tub on exterior wall Showers and tubs on exterior walls have insulation and an air barrier
se gratin them from the exterior wall,
Electrical/phone box on Air barrier extends behind boxes or air sealed-type boxes are
installed.
Common wall Air barrier is installed in common wall between dwelling units. �–
HVAC register boots HVAC register boots that penetrate building envelope are sealed to �-
subfloor or drywall.
Fire lace Fireplace walls include an air barrier.
EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software
Mc(;t)"W`aA Project Summary Job:
Date:
r ,gaa (Rest of House) By:
cur►diriorring`1
�,�• McGowan's Heating &Air Conditioning, Inc.
4850 Collins Road Orange Park,A 32073 Phone:904-278-0339 Fax:904-278-0366 Email:bacobs@mcgowansac.com Web:www.mcgowansac.com
For: Toll Brothers
FI
Notes: Catalina
Design Information
Weather: Jacksonville NAS, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 32 °F Outside db 94 °F
Inside db 70 °F Inside db 75 °F
Design TD 38 °F Design TD 19 °F
Daily range M
Relative humidity 50 %
Moisture difference 47 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 29607 Btuh Structure 22113 Btuh
Ducts 4208 Btuh Ducts 4891 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 33815 Btuh Use manufacturer's data n
Rate/swing multiplier 0.99
Infiltration Equipment sensible load 32581 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average 2888 Btuh
Fireplaces 0 Structure
Ducts 741 Btuh
Heating Cooling Central vent(0 cfm) 0 Btuh
Area(ft2) 2857 2857 Equipment latent load 3629 Btuh
Volume(ft) 32166 32166
Air changes/hour 0.25 0.13 Equipment total load 36210 Btuh
Equiv.AVF (cfm) 135 72 Req.total capacity at 0.70 SHR 3.9 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade Trade
Model CH14NA042 Cond CH14NA042
AHRI ref 6803260 Coil FB4CNP048
AHRI ref 6803260
Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER
Heating input Sensible cooling 28700 Btuh
Heating output 40000 Btuh @ 47°F Latent cooling 12300 Btuh
Temperature rise 27 °F Total cooling 41000 Btuh
Actual air flow 1367 cfm Actual air flow 1367 cfm
Air flow factor 0.040 cfm/Btuh Air flow factor 0.051 cfm/Btuh
Static pressure 0.50 in H2O Static pressure 0.50 in H2O
Space thermostat Load sensible heat ratio 0.88
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2014-Aug-27 10:54:57
wrilgI1 tsofV Comfort Builder by Wrightsoft 13.0.15 RSU12270 Page 1
...00 RES NC\Toll Brothers\CATALINA 4342 Sales.rup Calc=MJ8 House faces: W
Job:
��sO�VRIl% Project Summary Date:
Heating&Air UP STAIRS By:
Conditioning
:•. _,��«• McGowan's Heating &Air Conditioning, Inc.
4850 Collins Road Orange Park,FI 32073 Phone:904-278-0339 Fax:904-278-0366 Email:j acobs@mcgowansac.com Web:www.mcgowansac.com
Project Information
For: Toll Brothers
FI
Notes: Catalina
Design Information
Weather: Jacksonville NAS, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 32 °F Outside db 94 °F
Inside db 70 °F Inside db 75 °F
Design TD 38 °F Design TD 19 °F
Daily range M
Relative humidity 50 %
Moisture difference 47 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 19881 Btuh Structure 16006 Btuh
Ducts 2247 Btuh Ducts 2664 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 22127 Btuh Use manufacturer's data n
Rate/swing multiplier 0.99
Infiltration Equipment sensible load 17415 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 2492 Btuh
Ducts 400 Btuh
Heating Cooling Central vent(0 cfm) 0 Btuh
Area(ft2) 2168 2168 Equipment latent load 2892 Btuh
Volume(ft') 20706 20706
Air changes/hour 0.32 0.17 Equipment total load 20307 Btuh
Equiv.AVF(cfm) 112 60 Req.total capacity at 0.70 SHR 2.1 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade Trade
Model CH14NA024 Cond CH14NA024
AHRI ref 6803735 Coil FB4CNF024
AHRI ref 6803735
Efficiency 7.8 HSPF Efficiency 11.5 EER, 14 SEER
Heating Input Sensible cooling 16240 Btuh
Heating output 22600 Btuh @ 47°F Latent cooling 6960 Btuh
Temperature rise 27 °F Total cooling 23200 Btuh
Actual air flow 773 cfm Actual air flow 773 cfm
Air flow factor 0.035 cfm/Btuh Air flow factor 0.041 cfm/Btuh
Static pressure 0.50 in H2O Static pressure 0.50 in H2O
Space thermostat Load sensible heat ratio 0.87
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2014-Aug-27 10:54:57
Wrlghtslofr Comfort Builder by Wrightsoft 13.0.15 RSU12270 Page 2
...00 RES NC\Toll Brothers\CATALINA 4342 Sales.rup Calc=MJ8 House faces: W
" First Floor
6x14 12x6
8" 7^
y Tr GREAT ROOM
MASTER BED 6 x 14 12"
8,. 14x6 14x6
6' 8^
12x6
14" 7 10 x 6 Ret
Riser
16 x 16 16 611 18.
24 x 18 p
4 x 8 8 T Riser
4x8 4" „
4" 3"F DINING Riser
HIS WC 10 x 10 16"
Sup
10 x 1 ALL Riser
LAUND 9^ 10"
10 x 6 4 x ,LOSET
6., � 4..
12 x 12 12 x 6
91. 7^
M/1031TER BATH 10'
4 x 8 10"
3"Fan 4" 10 x 6 STUDY
HERS f"
FOYER
12x6 12x6
n,myr.nffc.
6x10
6 Y Fan
POW R'
8x4 14x14
sales area 4
4x8
4 14 x 14
WI 2 12^
3"Fan6x14 BED 2
H 6..
6x10
5'
Job #: McGowan's Heating & Air Conditioning Scale: 1 : 106
Performed for: Page 1
Toll Brothers 4850 Collins Road Comfort Builder by Wrightsoft
Orange Park,FI 32073 13.0.15 RSU12270
FI Phone:904-278-0339 Fax:904-278-0366 2014-Aug-2710:55:21
www.mcgowansac.com Jacobs@mcgowansac.com ...Brothers\CATALI NA 4342Sales.rup
N
2ND FL
bed 5
12x6 12x12
7' 9'
Ret
Riser
18" 18 Sup
bath 3 Riser
4 x 8 8 x 4 1NaY 12
4.. 4.. 12 12 16Sap
" 10 1
91.
^ mec nfini ed 16" Riser
10.1 Sup
Riser
16"
BED 6x12
7
2-way
12x6
7..
8x4 8 x 4 T
4" 4" 18x18
BATH SINKS 9"
3"Fa ® 10..
n 6 x 12
12 x 12 7" STAIRS/FOYER UP
12x6 9..
7„ LOFT
BED 4
6x12
7'
Job #: McGowan's Heating & Air Conditioning Scale: 1 : 106
Performed for: Page 2
Toll Brothers 4850 Collins Road Comfort Builder by Wrightsoft
Orange Park,FI 32073 13.0.15 RSU12270
FI Phone:904-278-0339 Fax:904-278-0366 2014-Aug-2710:55:21
www.mcgowansac.corn jjacobs@mcgowansac.com ...Brothers\CATALINA 4342 Sales.rup
�r Duct System Summa Job:
�''�.C�oW'a11 y � Date:
Heating&Air (Rest of House) By:
�Sr+clitiorting
McGowan's Heating &Air Conditioning, Inc.
4850 Collins Road,Orange Park,FI 32073 Phone:904-278-0339 Fax:904-278-0366 Email:pacobs@mcgowansac.com Web:www.mcgowansac.com
0111ramr-M •=71 •
For: Toll Brothers
FI
Heating Cooling
External static pressure 0.50 in H2O 0.50 in H2O
Pressure losses 0 in H2O 0 in H2O
Available static pressure 0.50 in H2O 0.50 in H2O
Supply/return available pressure 0.355/0.145 in H2O 0.355/0.145 in H2O
Lowest friction rate 0.129 in/100ft 0.129 in/100ft
Actual air flow 1367 cfm 1367 cfm
Total effective length (TEL) 387 ft
SupplyDetail Table
Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv
Name (Btuh) (Cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk
LAUNDRY c 78 3 4 0.172 4.0 Ox 0 VIFx 39.1 167.0 st8
WC c 23 0 1 0.164 4.0 Ox 0 VIFx 44.0 172.0 st8
MASTER BATH h 1862 75 35 0.168 6.0 Ox 0 VIFx 43.7 167.0 st8
HERS c 25 1 1 0.167 4.0 Ox 0 VIFx 45.5 167.0 st8
HIS h 543 22 7 0.164 4.0 Ox 0 VIFx 49.5 167.0 st8
MASTER BED h 2934 119 78 0.130 7.0 Ox 0 VIFx 69.0 205.0 st11
MASTER BED-A h 2934 119 78 0.130 7.0 Ox 0 VIFx 68.4 205.0 st11
NOOK/KITCHEN-A c 2447 74 124 0.129 7.0 Ox 0 VIFx 69.7 205.0 st11
NOOKIKITCHEN c 2447 74 124 0.227 7.0 Ox 0 VIFx 24.5 132.0 st3
GREAT ROOM c 4437 157 225 0.176 9.0 Ox 0 VIFx 37.2 165.0 st10
GREAT ROOM-A c 4437 157 225 0.171 9.0 Ox 0 VIFx 42.7 165.0 SO 0
DINING h 2228 90 62 0.167 6.0 Ox 0 VIFx 42.9 170.0 st10
STUDY c 2909 142 147 0.199 7.0 Ox 0 VIFx 38.5 140.0 st4
FOYER h 2162 87 50 0.192 6.0 Ox 0 VIFx 39.6 145.0 st4
POWDER c 55 2 3 0.143 4.0 Ox 0 VIFx 65.4 182.0 st9
BATH 2 h 1239 50 42 0.145 5.0 Ox 0 VIFx 63.1 182.0 st9
BED 2 h 4768 193 159 0.142 8.0 Ox 0 VIFx 62.3 187.0 st9
WIC 2 c 55 2 3 1 0.147 l 4.0 Ox 0 VIFx 59.1 182.0 st9
2014-Aug-27 10:54:57
" wrlghtsoft° Comfort Builder by Wrightsoft 13.0.15 RSU12270 Page 1
1R!�;.•=1�ik ...00 RES NC\Toll BrotherslCATALINA 4342 Sales.rup Calc=MJ8 House faces: W
Supply Detail Table
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk
s18 Peak AVF 101 48 0.164 289 8.0 0 x 0 VinlFlx st3
st9 Peak AVF 246 206 0.142 451 10.0 0 x 0 VinlFlx st3
SO 1 Peak AVF 311 280 0.129 397 12.0 0 x 0 VinlFlx st10
st10 Peak AVF 716 791 0.129 566 16.0 0 x 0 VinlFlx st4
st4 Peak AVF 946 989 0.129 708 16.0 0 x 0 VinlFlx
st3 Peak AVF 421 378 0.142 536 12.0 0 x 0 VinlFlx
TableReturn Branch Detail
Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk
rb1 Ox 0 409 323 112.4 0.129 382 14.0 Ox 0 VIFx rt2
rb11 Ox 0 476 404 85.6 0.170 1077 9.0 Ox 0 VIFx rt2
rb10 Ox 0 483 640 91.6 0.158 599 14.0 Ox 0 VIFx rt2
TableReturn Trunk Detail
Trunk Htg Cig Design Veloc Diam H x W Duct
Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk
rt2 Peak AVF 1367 1367 0.129 774 18.0 0 x 0 VinlFlx
2014-Aug-27 10:54:57
W rightSOft' Comfort Builder by Wrightsoft 13.0.15 RSU12270 Page 2
A—CU", .00 RES NC%Toll Brothers%CATALI NA 4342 Sales.rup Calc=MJ8 House faces: W
,(� + Duct System Summary Job:
y 7 Date:
# a UP STAIRS By
'"',
Cononi
McGowan's Heating &Air Conditioning, Inc.
4850 Collins Road,Orange Park,FI 32073 Phone:904-278-0339 Fax:904-278-0366 Email:jjacobs@mcgowansac.com Web:www.mcgowansac.com
Project Information
For: Toll Brothers
FI
Heating Cooling
External static pressure 0.50 in H2O 0.50 in H2O
Pressure losses 0 in H2O 0 in H2O
Available static pressure 0.50 in H2O 0.50 in H2O
Supply/return available pressure 0.308/0.192 in H2O 0.308/0.192 in H2O
Lowest friction rate 0.119 in/100ft 0.119 in/100ft
Actual air flow 773 cfm 773 cfm
Total effective length(TEL) 420 ft
Supply Detail Table
Design HtgClg Design Diam H x W Duct Actual Ftg.Egv
Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln(ft) Trunk
BED 4 c 1950 69 81 0.125 6.0 Ox 0 VIFx 45.1 200.0 st7
SINKS c 72 2 3 0.149 4.0 Ox 0 VIFx 32.0 175.0 st6
BATH h 393 14 10 0.145 4.0 Ox 0 VIFx 37.0 175.0 st6
BED 3 h 1850 65 64 0.151 6.0 Ox 0 VIFx 33.6 170.0 st6
LOFT c 2365 79 98 0.126 7.0 Ox 0 VIFx 38.7 205.0 st7
LOFT-A c 2365 79 98 0.119 7.0 Ox 0 VIFx 48.3 210.0 st7
LOFT-B c 2365 79 98 0.145 7.0 Ox 0 VIFx 36.4 175.0 st6
sinks 3 h 190 7 5 0.198 4.0 Ox 0 VIFx 20.3 135.0 st2
bath 3 h 305 11 8 0.192 4.0 Ox 0 VIFx 24.9 135.0 st2
bed 5 h 3517 123 119 0.197 7.0 OX 0 VIFx 21.4 135.0 st2
sales area h 2865 100 83 0.1587.0 Ox 0 VIFx 51.0 144.0 st5
sales area-A h 2865 100 83 0.156 7.0 Ox 0 VIFx 53.0 144.0 St5
con.mgr.offc. h 1331 46 25 0.147 5.0 Ox 0 VIFx 60.4 149.0 sty
SupplyDetail Table
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk
st5 Peak AVF 247 190 0.147 452 10.0 0 x 0 VinlFlx SO
st1 Peak AVF 247 190 0.147 452 10.0 0 x 0 VinlFlx
st2 Peak AVF 526 583 0.119 545 14.0 0 x 0 VinlFlx
st7 Peak AVF 227 277 0.119 507 10.0 0 x 0 VinlFlx st6
st6 Peak AVF 386 452 0.119 575 12.0 0 x 0 VinlFlx st2
2014-Aug-27 10:54:57
&+ wrightsoft' Comfort Builder by Wrightsoft 13.0.15 RSU12270 Page 3
...00 RES NC\Toll Brothers\CATALINA 4342 Sales.rup Calc=MJ8 House faces: W
Return Branch Detail Table
Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct
Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk
rb7 Ox 0 240 214 160.6 0.120 544 9.0 Ox 0 VIFx rt1
rb6 Ox 0 248 261 145.0 0.133 591 9.0 Ox 0 VIFx rt1
rb3 Ox 0 127 102 146.0 0.132 286 9.0 Ox 0 VIFx rt1
rb4 Ox 0 158 196 161.6 0.119 443 9.0 Ox 0 VI
rt1
TableReturn Trunk Detail
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk
rt1 Peak AVF 773 773 0.119 554 16.0 0 x 0 VinlFlx
2014-Aug-27 10:54:57
t wrightsoft. Comfort Builder by Wrightsoft 13.0.15 RSU12270 Page 4
s+.r
,4-0� ...00 RES NC\Toll Broth ers\CATALI NA 4342 Sales.rup Calc=MJ8 House faces: W
00
w
a
X
(2)2x6 SPF#2 POST. STRAP F X
TO POST BELOW W/2-CS18 cn c1t
STRAPS. a
CONVENTIONAL STRAP WALL TO 2x6 FULL HEIGHT
WALL 4
BEAM BELOW PER DETAIL 8/SO.2
X
HUS28-2
(2)2x6 SPF2 POST. SKEWED +�
i STRAP TO BEAM BELOW ��+'aHANGER X �L1� (2)2x6-:
i W/2-CS18 STRAPS. X X._
(3)2x12
(2)2x4 SPF#2
T. POST.
GIRDER BEAM [S-FG ABOVE 6x6 POST. STRAP TO STRAP BEAM EACH
4.
T. I POST BELOW W/2-CS18 END W/2-HTS16
( i STRAPS.
�T�X>j'TO HE�DER
BELOW W/2-CSB j
S1RAOS.
PARTIAL 2ND FLOOR FRAMING PLAN
8d63-/6-
- ---------
d63'/6'
N _ -__
_a
w
rn 6x6 POST ti
W/ ABU66
X
�'1 J
w STRAP BE
N ° i IEACH END
STRAP HEADER „ , ! W/2-MST 24 (2)2x6 BELOW POST
PER 7/SO.1 N ABOVE. STRAP POST 2x6 FULL HEIGHT
TOGETHER WITH (2)CS16. WALL
11A PROVIDE SOLID BLOCKING
50.2WITHIN FLOOR SYSTEM.
GIRDER TRUSS AG ABOVE_, GIRDER TRUSS FG2 ABO
(2)2x6 SPF#2. -- 1 ,k
POST.
5.25x7 1.8E
PARALLAM PS
>_I __ I w__ POST N
`- (3)2x6 BELOW POST
m o ABOVE. STRAP POST 1
N
C7 I I Q7 PO
,- TOGETHER WITH (2)CS16. FR
m PROVIDE SOLID BLOCKING t,isa+lliN#tyyy i TO
WITHIN FLOOR SYSTEM. Pd�y <<<i PR
cns v,
S o I U) ,`tip'` ..,�� C<<'<<<<p WIT
....
wJ •� F- 3� ••
<
v
PARTIAL IST FLOOR FRAMING FLAN .; No.53311
ST OF ,
,�, ��►� 9q
FILE COPY �: F w`
PROJECT
Lou Pontigo and LOT 1 ATLANTIC BEAC� �6 ;,
BUILDER
P Associates , 1 n . TOLL BROTHERS
420 Osceola AvenueJOB NO. SHT.NO.
fax. Beach,Florida 32250 TOLL-14-00372
Ph.242-0908 Fax.241-9557 (1 S K-3 FL:CA#8344 SC:CA#3579 DATE 0$.2'1.14 �J
American Builders Supply Engineering Cover Sheet
1801 7th St. S.W. Quote# B1402819A
Winter Haven, FL 33880 Order# 728315A 31
AMERICAN Phone: (863) 294-0611 Fax: (863) 293-1561 Printed: 08/28/14
Rl ALDERS SUPM Y
Customer Information: Job Information:
Model: Catalina
Toll Brothers -Jacksonville Job Name: Catalina
Address: LOUBlk/Sub: 1 -Atlantic Beach Country Club
160 Cape May Ave Phone: (904)217-0739 Address: IIIA/.l�tllIi Digitally signed by
Fax: (904)460-2683 TBD ��/� °�T yyilliamRanieri
City,State,Zip: _ _ Date:2014.08.29
Ponte Vedra,FL 32081 ckuglar@tollbrothersinc.com Jacksonville, FLS°� ���' 13:31:25-04'00'
General Truss Engineering Criteria &Design Loads(Individual Truss Design Drawings Show Special Loading Conditions):
Design Code: FBC2010rTP12007 Design Program: 7.52 May 8 2014 Roof Load: 40.0 psf Floor Load: 60.0 psf
Wind Code: MWFRS(Directional)/C-C hybrid Wind ASCE 7-10 Wind Speed: 130 mph
Engineer or Professional of Record:Luis A.Pontigo-420 Osceola Ave,Jacksonville Beach, FL 32250-#53311
This package includes 31 individual,dated Truss Design Drawings.
No. Date Truss ID# Seal#
069 08/28/2014 F A0020079
061 08/28/2014 F1 A002o071
062 08/28/2014 F2 A0020072
063 08/28/2014 F3 A0020073
064 08/28/2014 F4 Lou Pontigo & Associates, Inc.
A0020074
065 08/28/2014 F5 Aoozo075 Consulting Structural Engineers
066 08/28/2014 F6 A0020076 NO EXCEPTION TAKEN ❑ MAKE CORRECTIONS NOTED
067 08/28/2014 F7 A002oa77 JECTED - SEE REMARKS ❑ REVISE & RESUBMIT
068 08/28/2014 F7X A0020078
073 08/28/2014 FA A002oo83 Review is for the limited purpose of checking for conformance
07o 08/28/2014 FA1 A002ooao with the design concept and the Information expressed in the
071 08/28/2014 FA2 A0020081 contract documents. NO approval is Implied for the accuracy or
072 08/28/2018 FA3 Aoozooaz completeness of details, quantities, dimensions, weights or
074 08/28/2014 FAX A0020084 gauges, fabrication processes, construction means or methods,
coordination of the work with other trades or construction safety
o7s 08!28/2014 FB A0o2ooas precautions, all of which are the sole responsibility of the
o7s 08/28/2014 Fel A0020087 Contractor. The Contractor is responsible for dimensions to be
077 oa za/zola Fc Aoozooa7 confirmed and correlated at the site. Review of a specific item
079 08/28/2014 FCX A0020088shall not include a review of the entire assembly of which the
079 08/28/2014 FG1 A0020089 Item is a component. Review of re-submission will cover only
080 08/28/2018 FG2 Aoozooso designated changes an the submittal and other changes clearly
081 08/28/2014 FG3Ao020091 Identified by the Contractor.
082 08/28/2014 FG4 A0020092 , n
083 08128/2014 FGC A0020093 By. t`-�-fY Date: —�
084 08/28/2014 FT1 A002009A
085 08/28/2014 FT1X A0020095
086 08/2812014 FT2 A0020096 '`
087 08/28/2014 FT3 V020097
080 08/28/2014 FTA A0020098 FILE C �.
090 08/28!2014 FTA A0020100100
089 08/2812014 FTA4 A0020099 __
091 08/28/2014 FX A0020101 �M
William M. Ranieri, P.E. (Truss Design Engineer - Florida PE License # 42704) �.
Monta Consulting& Design of WMR&Associates, Inc.(CA#9177) ���,�•. •••••••.•�'Y/Ij
222 S.Westmonte Drive,Suite#100;Altamonte Springs, FL 32714;(407)681-1917 �•`.�;' LICENSE•=��
The truss drawing(s)referenced above have been prepared under my direct supervision based on the parameters ; No.42704
provided by:American Builders Supply.
With my seal affixed to this sheet,I hereby certify that I am the Truss Design Engineer and this index sheet ,✓/ • •
conforms to 61G15-31.003,section 5 of the Florida Board of Professional Engineers Rules. s STATE OF •4
UNLESS NOTED ABOVE,THERE IS NO STRUCTURAL ENGINEER OF RECORD AT THE TIME THESE DRAWINGS WERE SEALED
Q►
NOTE:The seal on these drawings indicate acceptance of professional engineering responsibilty solely for the truss components sho�. 4 d R`V'.A�N
_
The suitability and use of the component for any particular building is the responsibility of the building designer,per ANsirrpi 1-2007 ec.2. y S~•..••..•�
For hanger details and specifications not included in truss engineering package visit:www.strongtie.com. AU U 2 9 Z014
�I�NAI��
Page 1 of 1
William M. Ranieri, P c # 42704
American Builders Supply Engineering Cover Sheet
1801 7th St. S.W. Quote# B1402819
Winter Haven, FL 33880 Order# 728315B
AxtnuCA Phone: (863) 294-0611 Fax: (863)293-1561 Printed: 08/28/14
BEv.nEtu Surrty
Customer Information: Job Information:
Model: Catalina custom
Toll Brothers -Jacksonville Job Name: Catalina custom
Address: Lot/Blk/Sub: 1 -Atlantic Beach Country Club
160 Cape May Ave Phone: (904)217-0739 Address:
City,State,Zip: Fax: (904)460-2683 TBD
Ponte Vedra,FL 32081 ckuglar@tollbrothersinc.com Jacksonville, FL
General Truss Engineering Criteria &Design Loads(Individual Truss Design Drawings Show Special Loading Conditions):
Design Code: FBC20101TP12007 Design Program: 7.52 May 8 2014 Roof Load: 40.0 psf
Wind Code: MWFRS(Directional)iC-C hybrid Wind ASCE 7-10 Wind Speed: 130 mph
Engineer or Professional of Record:Luis A. Pontigo-420 Osceola Ave,Jacksonville Beach, FL 32250-#53311
This package includes 101 individual,dated Truss Design Drawings.
No. Date Truss ID# Seal#
130 08/28/2014 VE2 A0020140
132 08/28/2014 VEX A0020142
William M. Ranieri, P.E. (Truss Design Engineer - Florida PE License # 42704) M
Monta Consulting 8r Design of WMR 8r Associates, Inc.(CA#9177) ••"••
222 S.Westmonte Drive, Suite#100;Altamonte Springs, FL 32714;(407)681-1917x` ;'`LICENSE
The truss drawing(s)referenced above have been prepared under my direct supervision based on the parameters N0.42704
provided by:American Builders Supply.
With my seal affixed to this sheet,I hereby certify that I am the Truss Design Engineer and this index sheet ][ /y ]�
conforms to 61G15-31.003,section 5 of the Florida Board of Professional Engineers Rules. STATE OF
UNLESS NOTED ABOVE,THERE IS NO STRUCTURAL ENGINEER OF RECORD AT THE TIME THESE DRAWINGS WERE SEALED
NOTE:The seal on these drawings indicate acceptance of professional engineering responsibifty solely for the truss components shown. . 0F119• *a
The suitability and use of the component for any particular building is the responsibility of the building designer,per ANSI/TPI 1-2007 Spc 01(1 ••..s•s•`•
For hanger details and specifications not included in truss engineering package visit:www.strongtie.com. ,\uG G 1 1 t
Page 2 of 2 n •�/ A
William M. Ranieri, P c # 42704
DATE08/28/14 PAGE 2
Reaction Summary of Order REQ.QUOTE DATE / / ORDER# 728315A
ORDER DATE 06/16/14 QUOTE# B1402819A
DELIVERY DATE / / CUSTOMER ACCT# 000100389
DATE OF INVOICE / / CUSTOMER PO#
ORDERED BY James INVOICE#
TERMS CREDIT
nMrAKak
&.'W)EItS SIJITIISUPERINTENDANT James SALES REP Burt Harris
JOBSITE PHONE# (904)487-4063 SALES AREA
Toll Brothers-Jacksonville JOB NAME:Catalina LOT# 1 SUBDIV:Atlantic Beach Country
S
° 160 Cape May Ave MODEL:Catalina TAG: JOB CATEGORY:
D
T Ponte Vedra, FL 32081 DELIVERY INSTRUCTIONS:
D (904)217-0739
s
i SPECIAL INSTRUCTIONS:
P TBD
o Jacksonville, FL
BY DATE
BUILDING DEPARTMENT1 OVERHANG INFO HEEL HEIGHT 00-04-03 REQ.LAYOUTS REQ.ENGINEERING QUOTE
FLOOR ENDGUT RETURN I NONE NONE LAYOUT RF
PLUMB NO GABLE STUDS 24 IN.OC I CUTTING RF 08/28/14
FLOOR TRUSS SPACING:24.0 IN.O.C.(TYP.)
1.00
FLOOR QTY DEPTH BASE O/A END TYP INT BEARING Joint Number
PROFILE PLY ID SPAN SPAN REACTIONS Max Gravity
LEFT RIGHT SIZE LOCATION Max Uplift
® 01-0400 Joint 13 Joint 20
1 F1 22-0400 22-0400 1328.75 1328.75
O1-0400 Joint 14 Joint 20 Joint 22
® 1 F2 24-04-00 24-04-00 1: .08 1786.56 316.72
-91.60
® 014)400 Joint 15 Joint 21 Joint 23
1 F3 26-02-14 26-02-14 938.84 1856.21 437.56
® 01404-00 K: 3Joint 15 Joint 21 Joint 23
2 F4 26-02-14 26-02-14 938.83 1859.63 441.16
® 01-0400 Joint 14 Joint 19 Joint 22
3 F5 22-0914 22-0914IMF 724.45 1648.58 445.17
01-0400 Joint 6 Joint 9
1 F6 09-01-14 09-01-14 534.42 534.42
01-0400 Joint Joint 14
® 1 F7 14-00-00 1400 00 825.00 825.00
® 01-0400 K: 3Joint 10 Joint 11 Joint 12 Joint 13 Joint 14
1 F7X 10-0304 10-0304 44.55 136.14 165.14 158.70 160.23
01-04-00 Joint 10 Joint 16
® 7 FA 17-09 08 17-09-08 1046.25 1046.25
® 01-04-00 Joint 9 Joint 14
1 FA1 15-10-07 15-10-07 933.27 927.05
01-04-00 Joint 8 Joint 12
® 1 FA2 1310-07 1310-07 813.27 807.05
® 01-04-00 Joint 7 Joint 10
1 FA3 12-06-14 12-06-14 739.44 733.23
® 01 04 00 Joint 17 Joint 18 Joint 19 Joint 20 1 �!,
1 FAX 17-09-08 17-09 08 97.27 177.87 154.83 161. w 9. ■ R�
® 014)4-00 C 3 Joint 11 Joint 17 LICENSE ••. �m
8 FB 18-10 00 18-10-00 1115.06 1108.83 i
Nn 427n4-
STATE OF 4
s•..".. *
William M. Ranieri, P c # 42704
DATE08/28/14 PAGE 1
Reaction Summary of Order REQ.QUOTE DATE / ! ORDER# 728315B
ORDER DATE 06/16/14 QUOTE# B1402819
DELIVERY DATE / / CUSTOMER ACCT# 000100389
DATE OF INVOICE / / CUSTOMER PO#
ORDERED BY James INVOICE#
TERMS CREDIT
A,,caicn SUPERINTENDANT James SALES REP Burt Harris
suuvnLs Stmrn
JOBSITE PHONE# (904)487-4063 SALES AREA
Toll Brothers-Jacksonville JOB NAME:Catalina custom LOT# 1 SUBDIV:Atlantic Beach Country
° 160 Cape May Ave MODEL:Catalina custom TAG: JOB CATEGORY:
D
T Pointe Vedra, FL 32081 DELIVERY INSTRUCTIONS:
° (904)217-0739
s
i SPECIAL INSTRUCTIONS:
p TBD
o Jacksonville, FL
BY DATE
BUILDING DEPARTMENT1 OVERHANG INFO HEEL HEIGHT 00-04-03 REQ.LAYOUTS REQ.ENGINEERING QUOTE 1 / /
ROOF I END CUT RETURN NONE NONE LAYOUT IRF 07/15/14
PLUMB NO GABLE STUDS 24 IN.OC CUTTING
ROOF TRUSSES LOADING TCUL-TCDL$CLL-BCDL sTRess iNCR ROOF TRUSS SPACING:24.0 IN.O.C.(TYP.)
INFORMATION 20.0,10.0,0.0,10.0 1.25
PROFILE QTY PITCH TYPE BASE LUMBER VERHAN Joint Number
PLY ID O/A TOP BOT LEFT RIGHT REACTIONS Max Uplift
�
1 FLAT GIRDER 06-07-00 Joint 4Joint 6
2 Ply0.00 0.00 A-FG 06-07-00 2 X 4 2 X 6 984.70 1261.98
8706237100.00 -305.41 -336.26
HIP 54-09-04 Joint 2Joint 17 Joint 20 Joint 28
1 6.00 0.00 A10 54-09-04 2 X 4 2 X 4 01-0400 01-04-12 184.92 689.52 1751.73 2033.49
7778094401.00 -81.77 -265.83 -296.25 -503.67
HIP 47-11-07 Joint 2 Joint 15 Joint 17 Joint 25
1 6.00 0.00 Al2 47-11-07 2 X 4 2 X 4 01-04-00 338.80 242.63 1586.44 1964.67
6497690423.00 -113.69 -48.79 -361.24 -424.18
HIP 45-11-07 Joint 2 Joint 15 Joint 17 Joint 29
1 6.00 0.00 A14 45-11-07 2 X 4 2 X 4 01-0400 382.70 87.37 1580.84 1796.10
6040535415.00 -81.92 -30.03 -336.92 -461.82
HIP 44-10-13 Joint 2 Joint 14 Joint 17 Joint 26
1 6.00 0.00 A16 44-10-13 2 X 4 2 X 4 01-0400 501.09 568.89 1948.42 951.53
7617019072.00 -110.02 -183.99 -278.66 -320.82
ROOF 44-10-13 Joint 2 Joint 15 Joint 19 Joint 28
1 6.00 0.00 A18 44-10-13 2 X 4 2 X 4 01-0400 482.48 809.95 1482.98 1335.81
7746924050.00 -120.42 -219.51 -213.46 -340.10
ROOF 44-10-13 Joint 2 Joint 14 Joint 18 Joint 21
1 6.00 0.00 A20 44-10-13 2 X 4 2 X 4 01-0400 486.33 704.22 1594.98 1151.18
2462349140.00 -102.45 -127.27 -395.74 -268.01
HIP GIRDER 54-09-04 Joint 2 Joint 16 Joint 19 Joint 28
1 6.00 0.00 A7 54-09-04 2 X 4 2 X 4 01-04-00 01-04-12 362.35 894.31 3727.24 3681.84
3758378443.00 -196.61 -488.78 -987.25
HIP 54-09-04 Joint 2 Joint 16 Joint 19 Joint 27
1 6.00 0.00 A9 54-09-04 2 X 6 2 X 4 01-0400 01-04-12 614.01 1703.23 2350.60
4741071949.00 -313.82 -250.32 -306.27 -545.29
1 PIGGYBACK 19-00-00 Joint 8 Joint 16
2 Ply 6.00 0.00 AG 19-00-00 2 X 4 2 X 4 3103.46
2482052976.00 -993.44 -673.94
MONOPITCH 17-02-08 Joint 2 Joint 9 Joint 12
1 6.00 0.00 B 17-02-08 2 X 4 2 X 4 01-0400 373.23 341.99 791.65
5997402940.00 -23.79 -92.41 -262.14
MONOPITCH17-02-08 Joint 2 Joint 7 Joint 11
1 6.00 0.00 B1 17-02-08 2 X 4 2 X 4 01-04-00 308.90 488.98 695.28
4974444638.00 -17.56 -126.54 -234.24
MONOPITCH 17-02-08 Joint 2 Joint 7 Joint 11
1 6.00 0.00 B2 17-02-08 2 X 4 2 X 4 01-0400 281.54 528.14 756.20
6793511284.00 -30.48 -126.57 -223.28
MONOPITCH 17-02-08 Joint 2 Joint 8 Joint 12 M
1 6.00 0.00 B3 17-02-08 2 X 4 2 X 4 01-0400 285.00 499.32 695.38 A••,.••�••••
2875683517.00 -60.56 -131.60 -195.85 ol �N
EINS-
N0.42704 .��
STATE OF
Sox 0R10.60. �.
William M. Ranieri, P c # 42704
DATE 08/28/14 PAGE 3
Reaction Summary of Order REQ.QUOTE DATE / / ORDER# 728315B
ORDER DATE 06/16/14 QUOTE# B1402819
DELIVERY DATE / / CUSTOMER ACCT# 000100389
DATE OF INVOICE / / CUSTOMER PO#
i%6ORDERED BY James INVOICE#
TERMS CREDIT
A`)R SUPrLSUPERINTENDANT James SALES REP Burt Hams
BtatnERS SLmv
JOBSITE PHONE# (904)487-4063 SALES AREA
Toll Brothers-Jacksonville JOB NAME:Catalina custom LOT# 1 SUBDIV:Atlantic Beach Country
S
° 160 Cape May Ave MODEL:Catalina custom TAG: JOB CATEGORY:
D Pointe Vedra, FL 32081 DELIVERY INSTRUCTIONS:
D (904)217-0739
S
R SPECIAL INSTRUCTIONS:
P TBD
T Jacksonville, FL
BY DATE
BUILDING DEPARTMENT1 OVERHANG INFOI HEEL HEIGHT 00-04-03 REQ.LAYOUTS I REQ.ENGINEERING QUOTE 1 1 / /
ROOF END CUT RETURN LAYOUT RF 07/15/14
PLUMB No 241N.OC GABLE STUDS NONE NONE CUTTING / 1
ROOF TRUSSES LOADING TCu.-TCDL-8CLL-BCDL ROOF TRUSS SPACING:24.0 IN.O.C.(TYP.)
INFORMATION 20.0,10.0,0.0,10.0 1.25
QTY PITCH TYPE BASE L MBER VERHAN Joint Number
PROFILE REACTIONS Max Gravity
1PLY1 I ID O/A TOP BOT LEFT RIGHT Max Uplift
JACK-OPEN 02-11-04 Joint 3 Joint 4 Joint 5
L 2 6.00 0.00 CJ3A 02-11-04 2 X 4 2 X 4 01-0412 79.07 57.19 227.79
8339152445.00 -77.87 -47.24 -27.01
JACK-OPEN 05-00-00 Joint 3 Joint 4 Joint 5
2 6.00 0.00 CJ5 05-00-00 2 X 4 2 X 4 01-04-00 129.06 89.33 294.12
7480360665.00 -71.92 -93.31
JACK-OPEN 04-11-04 Joint 3 Joint 4 Joint 5
2 6.00 0.00 CJ5A 04-11-04 2 X 4 2 X 4 01-0412 140.03 90.21 296.74
6578395611.00 -105.91 -28.01 -24.55
COMMON 29-11-00 Joint 2 Joint 10
4 6.00 0.00 D 29-11-00 2 X 4 2 X 4 01-04-00 1278.49 1194.93
1404347836.00 -340.54 -276.91
1 FLAT GIRDER 09-10-00 Joint 5 Joint 8
2 Ply 0.00 0.00 D-FG 09-10-00 2 X 4 2 X 6 2834.13 3073.04
7921737795.00 1 -709.16 -768.22
COMMON 26-0500 Joint 2 Joint 9
2 6.00 0.00 D1 26-0500 2 X 4 2 X 4 01-04-00 1132.86 1048.80
8709232429.00 -303.69 -245.93
HIP 29-11-00 Joint 2 Joint 9
1 6.00 0.00 D11 29-11-00 2 X 4 2 X 4 01-04-00 1278.49 1194.93
2886681288.00 -340.54 -276.91
HIP29-11-00 Joint 2 Joint 10
1 6.00 0.00 D73 29-11-00 2X4 2 X 4 01-0400 1278.49 1194.93
2816949747.00 -340.54 -276.91
ROOF 29-11-00 Joint 2 Joint 10
1 6.00 0.00 D3 29-11-00 2 X 4 2 X 6 01-04-00 01-0400 1532.47 1424.60
6133198419.00 -442.71 -390.91
ROOF 29-11-00 Joint 2 Joint 10
1 6.00 0.00 D5 29-11-00 2 X 4 2 X 4 01-04-00 01-0400 1276.71 1276.71
2772610974.00 -339.21 -339.21
ROOF 29-11-00 Joint 2 Joint 10
1 6.00 0.00 D7 29-11-00 2 X 4 2 X 4 01-0400 01-04-00 1276.71 1276.71
9803263510.00 -339.21 -339.21
HIP 29-11-00 Joint 2 Joint 10
1 6.00 0.00 D9 29-11-00 2 X 4 2 X 4 01-04-00 01-04-00 1276.71 1276.71
9703745553.00 1 -339.21 -339.21
HIP 26-0500 Joint 2 Joint 9
1 6.00 0.00 DA10 26-0500 2 X 4 2 X 4 01-04-00 1132.86 1048.80
1601367283.00 1 1 -303.69 -245.93
HIP 26-05-00 Joint 2 Joint 9 ■
1 6.00 0.00 DA12 26-0500 2 X 4 2 X 4 01-0400 1132.86 1048.80 ���,..s...���•
5176394297.00 -303.69 -245.93
fe No.42704
s STATE OF
%.40R
William M. Ranieri, P c # 42704
Reaction Summary of Order REQ.QUOTE DATE I / / ORDER# DATE0 728/14 PAGE 5
' ORDER DATE 06/16/14 QUOTE# B1402819
DELIVERY DATE / / CUSTOMER ACCT# 1 000100389
DATE OF INVOICE / / CUSTOMER PO#
ORDERED BY James INVOICE#
TERMS CREDIT
r�MkRK:.A\
BLUDERY SUPPLY SUPERINTENDANT James SALES REP Burt Harris
JOBSITE PHONE# (904)487-4063 SALES AREA
S Toll Brothers-Jacksonville JOB NAME:Catalina custom LOT# 1 SUBDIV:Atlantic Beach Country
L 160 Cape May Ave MODEL:Catalina custom TAG: JOB CATEGORY:
T Ponte Vedra, FL 32081 DELIVERY INSTRUCTIONS:
D (904)217-0739
H
:rSPECIALSPECIAL INSTRUCTIONS:
P
T Jacksonville, FL
BY DATE
BUILDING DEPARTMENT OVERHANG INFOI HEEL HEIGHT 00-04-03 REQ.LAYOUTS REQ.ENGINEERING I QUOTE I ' / /
ROOF END CUT RETURN LAYOUT RF 07/15/14
241N.OC
PLUMB No GABLE STUDS NONE NONE CUTTING
ROOF TRUSSES LOADING TCLL-TCDLACLL-BCD' STRESS INCR. ROOF TRUSS SPACING:24.0 IN.O.C.(TYP.)
INFORMATION 20.0,10.0,0.0,10.0 1.25
PROFILE QTY1 PITCH TYPE BASE LUMBER OVERHANG, Joint Number
PLY ID O/A TOP BOT LEFT RIGHT REACTIONS Max Uplift
Gravity
JACK-OPEN 07-00-00 Joint 4 Joint 5 Joint 8
4 6.00 0.00 EJ7T 07-00-00 2 X 4 2 X 4 01-0400 145.61 97.19 462.22
6545308730.00 -81.48 -110.27
JACK-OPEN 07-00-00 Joint 4 Joint 5 Joint 8
6 6.00 0.00 EJ7T1 07-00-00 2 X 4 2 X 4 01-0400 145.63 101.17 468.51
2479421880.00 -81.11 -105.34
JACK-OPEN 04-06-04 Joint 3 Joint 4 Joint 5
12 6.00 0.00 EJK1 04-06-04 2 X 4 2 X 4 01-04-00 114.95 80.05 276.50
8292333278.00 -64.00 -92.07
JACK-OPEN 04-06-04 Joint 2 Joint 3 Joint 4
4 6.00 0.00 EJ K I S O4-06-04 2 X 4 2 X 4 122.35 82.37 172.54
6036746089.00 -70.24 -13.39
SCISSOR 19-04-00 Joint 11 Joint 15
2 6.00 3.00 G 19-04-00 2 X 4 2 X 4 01-04-00 01-0400 850.46 850.46
5547287040.00 -244.48 -260.40
COMMON 19-04-00 Joint 2 Joint 8
1 6.00 0.00 G1 19-04-00 2 X 4 2 X 4 01-0400 01-04-00 853.38 853.38
6295516809.00 -240.79 -240.79
COMMON 19-04-00 Joint 1 Joint 7
1 6.00 0.00 G2 19-04-00 2 X 4 2 X 4 01-0400 770.62 856.14
8727278849.00 -177.76 -242.84
COMMON 17-11-00 Joint 2 Joint 8
5 6.00 0.00 GA 17-11-00 2 X 4 2 X 4 01-0400 01-0400 796.67 796.67
1308497085.00 1 -227.60 -227.60
COMMON 17-11-00 Joint 2 Joint 8
1 6.00 0.00 GA1 17-11-00 2 X 4 2 X 4 01-0400 799.64 713.69
1483262772.00 -229.82 -164.41
COMMON17-11-00 Joint 2 Joint 8
2 6.00 0.00 GA2 17-11-00 2 X 4 2 X 4 01-04-00 799.64 713.69
2725139663.00 -229.82 -164.41
COMMON 17-11-00 Joint 2 Joint 8
1 6.00 0.00 GA2X 17-11-00 2 X 4 2 X 4 01-0400 01-0400 629.40 629.88
2155593074.00 -280.82 -280.80
MONOPITCH 05-11-00 Joint 1 Joint 3
1 6.00 0.00 GAG 05-11-00 2 X 4 2 X 6 942.06 907.01
1317805403.00 -204.02 -248.94
MONOPITCH 03-00-00 Joint 1 Joint 3
1 6.00 0.00 GG 03-00-00 2 X 4 2 X 6 541.51 437.44
4279414382.00 -115.04 -124.20
SCISSOR 19-0400 Joint 9 Joint 13
1 6.00 3.00 GX 19-0400 2X4 2X4 01-04-00 01-04-00 826.49 871.31 .,���-
2753495613.00 -242.71 -266.40
c N0.42704
STATE OF
�X d
asRIP
s .. ..
....,
�DNAt�
William M. Ranieri, P c # 42704
DATE08/28/14 PAGE 7
Reaction Summary of Order REQ.QUOTE DATE / / ORDER# 728315B
ORDER DATE 06/16/14 QUOTE# B1402819
DELIVERY DATE / / CUSTOMER ACCT# 000100389
DATE OF INVOICE / / CUSTOMER PO#
C`r ORDERED BY James INVOICE#
TERMS CREDIT
AD
ER
&/LLUER$SIMPLY
SUPERINTENDANT James SALES REP Burt Harris
JOBSITE PHONE# (904)487-4063 SALES AREA
S Toll Brothers-Jacksonville JOB NAME:Catalina custom LOT# 1 SUBDIV:Atlantic Beach Country
° 160 Cape May Ave MODEL:Catalina custom TAG: JOB CATEGORY:
D
T Ponte Vedra, FL 32081 DELIVERY INSTRUCTIONS:
° (904)217-0739
s
e TBD SPECIAL INSTRUCTIONS:
o Jacksonville, FL
BY DATE
BUILDING DEPARTMENTI OVERHANG INFO HEEL HEIGHT 00-04-03 1 REQ.LAYOUTS REQ.ENGINEERING QUOTE
ROOF ENDCUT1 RETURN I NONE NONE LAYoUT IRF o7/t5/1a
PLUMB NO I GABLE STUDS 24 IN,OC I CUTTING 1 1 //
ROOF TRUSSES LOADING TCLL-TCDLACLLACDL srRess INCR. ROOF TRUSS SPACING:24.0 IN.O.C.(TYP.)
INFORMATION 20.0,10.0,0.0,10.0 1.25
PROFILE QTY I PITCH TYPE BASE I LUMBER OVERHANG Joint Number
PLY ID O/A TOP BOT LEFT RIGHT REACTIONS Max Ur
aiftry
DIAGONAL HIP 03-09-03 Joint 3 Joint 4 Joint 5
1 1 4.241 0.00 HJ28 03-09-03 2 X 4 2 X 4 01-10-10 62.10 27.51 214.82
2940873061.00 -29.01 -15.84 -126.82
DIAGONAL HIP 04-01-07 Joint 3 Joint 4 Joint 5
1 4.24 0.00 HJ3 04-01-07 2 X 4 2 X 4 01-10-10 68.59 38.81 206.08
4099850135.00 _ _ -27.23 -116.39
DIAGONAL HIP 04-02-03 Joint 3 Joint 4 Joint 5
2 4.24 0.00 HJ3H 04-02-03 2 X 4 2 X 4 01-10-10 75.37 39.49 222.31
7333563538.00 -36.44 -6.16 -126.73
DIAGONAL HIP 05-07-02 Joint 2 Joint 3 Joint 4
1 2.12 0.00 HJ4F 05-07-02 2 X 4 2 X 4 01-10-10 353.69 138.98 99.01
3513529400.00 -163.19 -62.59
DIAGONAL HIP 09-1001 Joint 4 Joint 5 Joint 8
1 4.24 0.00 HJ7 09-1001 2 X 4 2 X 4 01-1010 166.49 266.54 391.38
643189228.00 -91.12 -51.73 -148.81
DIAGONAL HIP 09-09-00 Joint 4 Joint 5 Joint 8
1 4.24 0.00 HJ7A 09-09-00 2 X 4 2 X 4 01-11-11 149.90 362.18 607.39
604287248.00 -104.61 -335.45 -646.20
j MONOPITCH 11-11-08 Joint 2 Joint 5
8 3.00 0.00 J 11-11-08 2 X 4 2 X 4 01-04-00 576.31 448.75
2432819772.00 -164.34 -116.37
MONOPITCH 11-11-08 Joint 2 Joint 10 Joint 11Joint 12 Joint 13
1 3.00 0.00 JX 11-11-08 2 X 4 2 X 4 01-0400 226.22 39.63 107.79 108.43 101.36
783680935.00 -82.23 -12.13 -25.57 -28.58 -27.45
COMMON 15-07-11 Joint 2 Joint 6
1 5.54 0.00 K 15-07-11 2 X 4 2 X 6 01-05-05 1489.90 1406.01
2461164391.00 -583.48 -514.80
® FLAT GIRDER 02-09.14 Joint 3 Joint 4
4 0.00 0.00 K-FG 02-09-14 2 X 4 2 X 4 217.71 217.82
5686557241.00 -59.28 -59.32
MONOPITCH 07409-02 Joint 2 Joint 5
2 5.54 0.00 KG 07-09-02 2 X 4 2 X 6 01-05-05 461.00 509.94
1458573709.00 -144.93 -201.05
DIAGONAL HIP 06-03-13 Joint 2 Joint 12
3 5.54 0.00 KG1 06-03-13 2 X 4 2 X 4 01-05-05 01-0300 317.96 234.29
1410958648.00 -74.82 -172.73
DIAGONAL HIP 06-0314 Joint 5 Joint 7
1 5.54 0.00 KG1 S 06-0314 2 X 4 2 X 4 01-03-00 221.58 265.72
7790441922.00 -3.82 -189.29
GABLE 17-07-00 Joint 1 Joint 11 Joint 12 Joint 1 t 1
1 6.000.00 V7 17-07-00 2 X 4 2 X 4 97.47 97.33 238.01 �•••llKL.••-
7656062671.00 8.48 8.48 79.83 .�•
No.42704 14 e
STATE OF
4.4 0 Rl'p Sao*
�NAI�
William M. Ranieri, P c # 42704
Dwg
O Truss Truss Type _ __ 9
1728315 F Floor 6 1 Job Reference(optional) No 069
American Builders Supply,Sanford,FL 32771 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Thu Aug 2815:31:07 2014 Page 1
ID:c8A3zpKbMfNUP?GwJa8Yk9zZjN-N P?DQXFh8i9847bTwHN0eW7m9oOhT9nM2zbiQeyjHy2
0-1-8
H i 2-6-01 1-" i 2-M 14-0
Scale=1:33.5
Dead Load Defl.=5116 in
2X4 11 2x4 11
2x4= 4x8= 2x4 II 3x4= 2x4 II 2x4 II 3x4= 3x6 FP= 4x8= 3x4 II
1 2 3 4 5 6 7 8 9 10 11
1
-17
17 16 15 14 13
3x6= 3x10 MT20H FP= 3x4= 3x4= 4x10= 3x8=
4x10= 2x4 SP--
10-4-0 115$
9-2-8 9 + 11 -0 20-8-0
9.2-8 0•-81-" 1-0-00.18 9-2
Plate Offsets(X,Y)- [5:0-1-8,Edge],[6:0-1-8,040-0],[14:0-1-8,Edge],[15:0-1-8,Edge],[19:0-1-8,0-1-0]
LOADING(psf) SPACING- 2-" CSI. DEFL. in (loc) I/defl L/d PLATES GRIP
TCLL 40.0 Plates Increase 1.00 TC 0.65 Vert(LL) -0.39 14-15 >632 360 MT20 244/190
TCDL 10.0 Lumber Increase 1.00 BC 0.93 Vert(TL) -0.68 14-15 >362 240 MT20H 187/143
BCLL 0.0 Rep Stress Incr YES WB 0.88 Horz(TL) 0.12 12 n/a n/a
BCDL 10.0 Code FBC20101TP12007 (Matrix) Weight:103 Ib FT=20%F,11%E
LUMBER- BRACING-
TOP CHORD 2x4 SP M 30(flat)"Except' TOP CHORD Structural wood sheathing directly applied or 5-6-11 oc purlins, except
T2:2x4 SP No.2(flat) end verticals.
BOT CHORD 2x4 SP M 30(flat) BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS 2x4 SP No.3(flat)
REACTIONS. (Ib/size) 18=1219/0-4-0 (min.0-1-8),12=1225/0-6-0 (min.0-1-8)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 2-3=-3994/0,3-4=-3994/0,4-5=-513010,5-6=-5130/0,6-7=-5130/0,7-8=-3993/0,8-9=-3993/0,9-10=-3993/0
BOT CHORD 17-18=0/2331,16-17=0/4878,15-16=0/4878,14-15=0/5130,13-14=0/4878,12-13=0/2335
WEBS 5-15=-343/38,6-14=-343/38,2-18=-2561/0,2-17=0/1838,3-17=-257/0,4-17=-977/0,4-15=-94!712,10-12=-2570/0,
10-13=0/1834,8-13=-255/0,7-13=-979/0,7-14=-94/712
NOTES- (7)
1)Unbalanced floor live loads have been considered for this design.
2)All plates are MT20 plates unless otherwise indicated.
3)The Fabrication Tolerance at joint 16=11%
4)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
5)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to
be attached to walls at their outer ends or restrained by other means.
6)CAUTION,Do not erect truss backwards.
7)Segn:A0020079,Date:08/28/2014
LOAD CASE(S) Standard
M.
......114
;•' LICENSE
s N0.42704
i STATE 8F0 RIP
=4
.0"401
04,
William M. Ranieri, P c # 2704
O Russ ;���� JobRfw
1728315 F2 1 1 Dvg No 062
ence(optional)
American Builders Supply,Sanford,rc 32771 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc.Thu Aug 2815:31:08 2014 Page 1
pig ID:c8A3zpKbMfNUP?GwJa8Yk9zZbN-rbZcesGJvOH_iHAgU_uFBjgusBi7CadVHdKFy4yjHy1
22 �� F 2-M 1-4-0
Scale=1:39.4
Dead Load Defl.=1/4 in
4x10= 2x4 II 3x4=
3x6= 3x4= 2x4 11 3x6= 2x4 11 3x4= 3x6 FP= 2x4 11 3x6= 3x4 11
1 2 3 4 5 Ti 6 7 8 9 10 11 12 13
1 Y
11RiI
22 21 20 19 18 17 16 15 14
3x10= 3x8= 4x6=3x6 FP= 4x10= 2x4 II 3x4= 3xB= 3x6=
6-11-6-2-8 15-1-8
5-&0 (r2-127�1rp 13-0-0 14-0-0 15-0-024 -0
-0-
' 50 b-8-12 0-1'-B 5-9.8 1-0-0 ' 1-0-0 " 9-2-8
0-8-18-1-8 0-1-8
Plate Offsets(X,Y)— [7:0-1-8,Edge],[8:0-1-8,0-M],[16:0-1-8 Edge] [17:0-1-8 Ed e]
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP
TCLL 40.0 Plates Increase 1.00 TC 0.84 Vert(LL) -0.3615-16 >568 360 MT20 244/190
TCDL 10.0 Lumber Increase 1.00 BC 0.98 Vert(TL) -0.6315-16 126 240
BCLL 0.0 Rep Stress Incr YES WB 0.97 Horz(TL) 0.05 14 n/a n/a
BCDL 10.0 Code FBC2010/TPI2007 (Matrix) Weight:1271b FT=20%F,11%E
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2(flat)`Except' TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except
T1:2x4 SP M 30(flat) end verticals.
BOT CHORD 2x4 SP No.2(flat)*Except* BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
B2:2x4 SP M 30(flat)
WEBS 2x4 SP No.3(flat)
REACTIONS. (Ib/size) 22=168/0-3-15 (min.0-1-8),20=1787/0-4-0 (min.0-1-8),14=928/0-6-0 (min.0-1-8)
Max Uplift22=-92(LC 4)
Max Grav22=317(LC 3),20=1787(LC 1),14=935(LC 4)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 2-3=-79/803,3-4=-79/803,4-5=0/1370,5-6=-1161/0,6-7=-1161/0,7-8=-2690/0,
8-9=-2690/0,9-10=-2690/0,10-11=-2764/0,11-12=-2764/0
BOT CHORD 21-22=-344/372,20-21=-1370/0,19-20=-831/0,18-19=-831/0,17-18=0/2690,16-17=0/2690,
15-16=0/3004,14-15=0/1719
WEBS 7-17=0/254,4-20=-638/0,2-22=-408/378,2-21=-672/0,4-21=0/996,7-18=-1707/0,
5-18=0/2028,5-20=-1292/0,12-14=-1892/0,12-15=0/1156,10-15=-265/0,10-16=-529/32
NOTES- (6)
1)Unbalanced floor live loads have been considered for this design.
2)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s)22.
3)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to
be attached to walls at their outer ends or restrained by other means.
5)CAUTION,Do not erect truss backwards.
6)Segn:AO020072,Date:08/28/2014
LOAD CASE(S) Standard
0.0124
-N�
' LICENSE
fe No.42704
STATE 8F
� aR1p4;.-
iQw•r..s►r����
VM\•�NAt�
William M. Ranieri, P c # 42704
oruss truss ype
Dwg No 064
'Jty ply
728315 , F4 Floor 2 1
Job Reference(optional)
American Builders Supply,Sanford,FL32771 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 Mi7ek Industries,Inc. Thu Aug 2815:31:09 2014 Page 1
ID:c8A3zpKbMfNUP7GwJa8Yk9zZjN-Jn6_rCHygJPrKRks1iOUlocC3Sb2Cx1rfVH4oVXyj it
2--'U1"l"6— �2-0-0 i 1-"
Scale=1:42.8
Dead Load Defl.=1/4 in
4x10= 3x4=
3x4 II 3x4= 2x4 11 3x6= 3x4 11 2x4 II 3x6 FP= 2x4 II 3x4= 2x4 II 3x6= 3x4 II
1 2 3 4 5 6 7 8 9 10 11 12 13 14
� 1 14
23 22 21 20 19 18 17 16 15
3x6= 3x8= 4x6=3x6 FP= 4x10= 2x4 II 3x4= 3x8= 3x6=
9-1-6 16-10-14
8-10-6 6-11,14 14-10-14 15-10-1q 17rQ-6 26-2-14
B-10-6 0- 5-9-8 1-0-0 1-0-0 9-2-8 '
0-1-8 0-1-8
Plate Offsets(X,Y)— [1:Edge,0-1-8],[9:0-1-8,Edge],[10:0-1-8,0-M] [17:0-1-8 Edge] [18:0-1-8 E e] —
LOADING(psi) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP
TCLL 40.0 Plates Increase 1.00 TC 0.85 Vert(LL) -0.36 16-17 >571 360 MT20 244/190
TCDL 10.0 Lumber Increase 1.00 BC 0.99 Vert(TL) -0.62 16-17 >329 240
BCLL 0.0 Rep Stress Incr YES WB 0.97 Horz(TL) 0.05 15 n/a n/a
BCDL 10.0 Code FBC2010/TP12007 (Matrix) Weight:135 Ib FT=20%F,11%E
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2(flat)*Except* TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except
T2:2x4 SP M 30(flat) end verticals.
BOT CHORD 2x4 SP No.2(flat)*Except* BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
B2:2x4 SP M 30(flat)
WEBS 2x4 SP No.3(flat)
REACTIONS. (Ib/size) 23=334/Mechanical,21=1860/0-4-0 (min.0-1-8),15=926/0-6-0 (min.0-1-8)
Max Grav23=441(LC 3),21=1860(LC 1),15=939(LC 4)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 2-3=-637/376,3.4=-637/376,4-5=0/1426,5-6=0/1426,6-7=-1206/0,7-8=-1206/0,
8-9=-1206/0,9-10=-2721/0,10-11=-2721/0,11-12=-2780/0,12-13=-2780/0
BOT CHORD 22-23=-127/637,21-22=-949/0,20-21=-880/0,19-20=-880/0,18-19=0/2721,17-18=0/2721,
16-17=0/3030,15-16=0/1726
WEBS 9-18=0/260,2-23=-701/140,2-22=-276/0,3-22=-250/0,4-22=0/1076,4-21=-928/0,
9-19=-1715/0,6-19=0/2033,6-21=-1312/0,13-15=-1900/0,13-16=0/1166,11-16=-276/0,
11-17=-548/23
NOTES- (6)
1)Unbalanced floor live loads have been considered for this design.
2)Refer to girder(s)for truss to truss connections.
3)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to
be attached to walls at their outer ends or restrained by other means.
5)CAUTION,Do not erect truss backwards.
6)Segn:A0020074,Date:08/28/2014
LOAD CASE(S) Standard
�M 7m.
I. LICENSE•'���m
No.42704
STATE OF
4.4 0F1VIP!
�NAI�
William M. Ranieri, P c # 42704
Truss Qty Ply
Dwg No 066
728315 � F6 Fkx>. 1 1
Job Reference(optional)
American Builders Guppy,Sanford,FI_JL//1 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MTek Industries,Inc.Thu Aug 2815:31:10 2014 Pagel
ID:c8A3zpKbMfNUP?GwJa8Yk9zZjN-nzg M3YIandXixbJ2bP4G81HY?TQgfhokxpM 1 zyj Hy?
2-8-0 1 0-0 2-4-14
Scale=1:16.4
Dead Load Defl.=1/4 in
3x4 11 3x4= 3x4= 3x4
1 2 32" 11 4 5
L 1 4 ER
Y
9 3x6 8 7 3x4
2x4 11
3x6=
2-10-83 4 8 3 10-8 9-1-14 - -
2-10-8 0 6 0 0-6-0 5-3-6
Plate Offsets(X,Y)- [1:Edge,0-1-8],[2:0-1-8,Edge],L3:0-1-8,0-0-01,[7:0-1-8 Edge] [8:0-1-8 Edge]
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) /deft Ud PLATES GRIP
TCLL 40.0 Plates Increase 1.00 TC 0.62 Vert(LL) -0.10 6-7 >999 360 MT20 244/190
TCDL 10.0 Lumber Increase 1.00 BC 0.67 Vert(TL) -0.34 6-7 >318 240
BCLL 0.0 Rep Stress Incr YES WB 0.29 Horz(TL) 0.02 6 n/a n/a
BCDL 10.0 Code FBC2010/TPI2007 (Matrix) Weight:49 Ib FT=20%F,11%E
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
BOT CHORD 2x4 SP No.2(flat) end verticals.
WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (Ib/size) 9=534/Mechanical,6=534/0-4-0 (min.0-1-8)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 2-3=-954/0,3-4=-954/0
BOT CHORD 8-9=0/954,7-8=0/954,6-7=0/845
WEBS 4-6=-930/0,2-9=-1046/0,4-7=0/263
NOTES- (5)
1)Unbalanced floor live loads have been considered for this design.
2)Refer to girder(s)for truss to truss connections.
3)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to
be attached to walls at their outer ends or restrained by other means.
5)Segn:A0020076,Date:08/28/2014
LOAD CASE(S) Standard
LICENSE�%. a
No.42704
STATE OF
N4
0 RID,,�;'����v4''
William M. Ranieri, P c # 42704
russ cuss ypeIY
728315 F7X Fb sSupported Gable 1 1 DAg No 068
Job Reference(optional)
American Builders Supply,Sanford,FL 32771 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Thu Aug 2815:31:11 2014 Page 1
I D:c8A3zpKbMfN UP?GwJa8Yk9zZbN-FAEkGuICCxfZZkuF97SypMlaOPzpPAyyzbZvZF
Scale:3/4'=1'
1 2 3 4 5 6 7 8 9
T T 3 STI. T T 3 ER
Y
18 17 16 15 14 13 12 11 10
10-34
10-34
Plate Offsets(XY)- [9:0-1-8,Edge],[10:0-1-8,Edge]
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP
TCLL 40.0 Plates Increase 1.00 TC 0.08 Vert(LL) n/a n/a 999 MT20 244/190
TCDL 10.0 Lumber Increase 1.00 BC 0.02 Vert(TL) n/a n/a 999
BCLL 0.0 Rep Stress Incr YES WB 0.03 Horz(TL) 0.00 10 n/a n/a
BCDL 10.0 Code FBC2010/TP12007 (Matrix) Weight:45 Ib FT=20%F,11%E
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
BOT CHORD 2x4 SP No.2(flat) end verticals.
WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3(flat)
REACTIONS. All bearings 10-34.
(lb)- Max Grav All reactions 250 Ib or less at joint(s)18,10,17,16,15,14,13,12,11
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown.
NOTES- (7)
1)All plates are 2x4 MT20 unless otherwise indicated.
2)Gable requires continuous bottom chord bearing.
3)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web).
4)Gable studs spaced at 1-4-0 oc.
5)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
6)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-1Od(0.131"X 3")nails. Strongbacks to
be attached to walls at their outer ends or restrained by other means.
7)Segn:AO020078,Date:08/28/2014
LOAD CASE(S) Standard
�N1 M.
c No.42704
STATE OF
400.
0. %. 0 R�D,,�:•' ti
William M. Ranieri, P c # 42704
lob cuss russ ype
0 Dwg No 070
728315 FA1 Floor 1 1
[Job Reference(optional)
American Builder's Supply,Sanford,FL 32771Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MTek Industries,Inc.Thu Aug 2815:31:12 2014 Page 1
ID:c6A3zpKbMtNUP?GwJa8Yk9zZpN�Mo6UEJgzEnQBuTP4gzBLZqdQp9x8VB5BFIT4rAHxz
0-1-8
H 2-6-0 { 1-2-15 {I 1-0-0
Scale=1:25.4
Dead Load Dell.=3/16 in
2x4 11
2x4= 3x6= 2x4 11 3x4= 2x4 11 3x6= 34=
1 2 3 4 53x4— 6 7 8
E X ------T—
' v
-114
13 12 11 10
3x6= 3x8= 2x4 11 2x4 II 3x8= 3x10=
i 6-&15 7-2-157 -15, 1510-7
6-8-15 0�-0 0�-0 8-1-8
Plate Offsets(X,Y)— [4:0-1-8,Edge],[5:0-1-8,Edge],[11:0-1-8,0-0-0],[12:0-1-8 Edge] [15:0-1-8,0-1-01
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP
TCLL 40.0 Plates Increase 1.00 TC 0.61 Vert(LL) -0.17 10-11 >999 360 MT20 244/190
TCDL 10.0 Lumber Increase 1.00 BC 0.67 Vert(TL) -0.31 9-10 >595 240
BCLL 0.0 Rep Stress Incr YES WB 0.54 Horz(TL) 0.05 9 n/a n/a
BCDL 10.0 Code FBC2010/TPI2007 (Matrix) Weight:84 Ib FT=20%F,11%E
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2(fiat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
BOT CHORD 2x4 SP M 30(flat) end verticals.
WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (Ib/size) 14=927/0-511 (min.0-1-8),9=933/0-3-15 (min.0-1-8)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 2-3=-2722/0,311=-2722/0,4-5=-2978/0,5-6=-2770/0,6-7=-2770/0
BOT CHORD 13-14=0/1705,12-13=0/2978,11-12=0/2978, 10-11=0/2978,9-10=0/1736
WEBS 7-9=-1903/0,2-14=-1871/0,7-10=0/1143,2-13=0/1124,6-10=-284/0,5-10=467/92,4-13=-545/50
NOTES- (5)
1)Unbalanced floor live loads have been considered for this design.
2)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to
be attached to walls at their outer ends or restrained by other means.
4)CAUTION,Do not erect truss backwards.
5)Segn:A0020080,Date:08/28/2014
LOAD CASE(S) Standard
LICENSE�•;��s
No. 2704
STATE OFk. =
s"OfAtiti�`
William M. Ranieri, P c # 42704
JobNSS NSS ype
• � Dwg No]072
728315 FA3 Floor 1 1
Qty ply
Job Reference(optbnal)
American builders supply,Sanford,FL 32771 Run:7.520 s May 8 2014 Pr nt:7.520 s May 8 2014 MTek Industr es,Inc. Thu Aug 28 15:31:13 2014 Page 1
ID:c8A3zpKbMflVUP?GwJa8Yk9zZh N-CYMVhaKSkYvHo22dGXUQunNpXCS9t_gEQv20d IyI Hxy
0-1-8
H 1 2-0-0 1-9-14
Scale=1:20.2
Dead Load Defl.=3/16 in
2x4 11
2x4= 3x4= 2x4 11 2x4 11 3x4= 3x4 11
1 2 3 4 5 6
1
ERI
Y
9 83x4-
3x6= 3x4= 3x8=
5-48 6-3-7 7-2$ 12$14
5-4-8 Q:10_1
10 15 0-10-15 54-8
Plate Offsets(X,Y)7 [3:0-1-8,Edge],[4:0-1-8,0-0-0],[8:0-1-8,Edge],[9:0-1-8,Edge],111:0-1-8,0-1-01
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/dPLATES GRIP
TCLL 40.0 Plates Increase 1.00 TC 0.53 Vert(LL) -0.16 9-10 >944 360 MT20 244/190
TCDL 10.0 Lumber Increase 1.00 BC 0.86 Vert(TL) -0.39 9-10 >384 240
BCLL 0.0 Rep Stress Incr YES WB 0.39 Horz(TL) 0.03 7 n/a n/a
BCDL 10.0 Code FBC2010/TPI2007 (Matrix) Weight:63 Ib FT=20%F,11%E
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
BOT CHORD 2x4 SP No.2(flat) end verticals.
WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (Ib/size) 10=733/0-5-4 (min.0-1-8),7=739/0-5-8 (min.0-1-8)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown.
TOP CHORD 2-3=-1898/0,3-4=-1898/0,4-5=-1898/0
BOT CHORD 9-10=0/1281,8-9=0/1898,7-8=0/1283
WEBS 5-7=-1413/0,2-10=-1405/0,5-8=0/769,2-9=0/769
NOTES- (5)
1)Unbalanced floor live loads have been considered for this design.
2)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to
be attached to walls at their outer ends or restrained by other means.
4)CAUTION,Do not erect truss backwards.
5)Segn:A0020082,Date:08/28/2014
LOAD CASE(S) Standard
'LICENSE =��
No.427Q4
STATE OF
; 4
William M. Ranieri, P c # 42704
lob Inuss nlss
yPe
• Dwg No 076
728315 FB Floor 8 1
Job Reference(optional)
American Builders Supply,Sanford,FL 32771 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc.Thu Aug 28 15:31:14 2014 Page 1
ID:c8A3zpKbMfNUP?GwJa8Yk9zn N-glwtuwL4Vs18QCdpgF?fR_vxmcnZcMUOfZnZ9kyjHxx
0-1-8
H i 2-6-0 1-1D ;
Scale=1:30.5
Dead Load Defl.=1/4 in
2x4 11 2x4 11
2x4= 3x10= 2x4 11 3x4= 2x4 II 3x4= 3x6 FP= 3x10= 3x4 11
1 2 3 4 5 6 7 8 9 10
EM
1 Y
16 15 14 13 12 11
3x6= 3x10= 3x10 MT20H FP= 3x4= 300= 3x6=
2x4 II
8.0-0 18
8-0-0 9-10-010.0
_
Plate Offsets(X,Y)- [4:0-1-8,Edge] [5:0-1-8,0-M],[13:0-1-8 Edge] [14:0-1-8 Edge] [18:0-1-8,0-1-01
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP
TCLL 40.0 Plates Increase 1.00 TC 0.75 Vert(LL) -0.31 12-13 >713 360 MT20 244/190
TCDL 10.0 Lumber Increase 1.00 BC 0.85 Vert(TL) -0.58 12-13 >384 240 MT20H 187/143
BCLL 0.0 Rep Stress Incr YES WB 0.75 Horz(TL) 0.09 11 n/a n/a
BCDL 10.0 Code FBC2010/TP12007 (Matrix) Weight:96 Ib FT=20%F,11%E
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 4-9-13 oc purlins, except
BOT CHORD 2x4 SP M 30(flat) end verticals.
WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (Ib/size) 17=1109/0-5-4 (min.0-1-8),11=1115/Mechanical
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 2-3=-3512/0,3-4=-3512/0,4-5=-4242/0,5-6=-4242/0,6-7=-3524/0,7-8=-3524/0,8-9=-3524/0
BOT CHORD 16-17=0/2093,15-16=0/4242,14-15=0/4242,13-14=0/4242,12-13=0/4181,11-12=0/2100
WEBS 9-11=-2312/0,2-17=-2298/0,9-12=0/1573,2-16=0/1569,3-16=-274/0,6-12=-726/0,4-16=-980/0,6-13=-248/438
NOTES- (7)
1)Unbalanced floor live loads have been considered for this design.
2)All plates are MT20 plates unless otherwise indicated.
3)Refer to girder(s)for truss to truss connections.
4)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
5)Recommend 2x6 strong backs,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X3")nails. Strongbacks to
be attached to walls at their outer ends or restrained by other means.
6)CAUTION,Do not erect truss backwards.
7)Segn:A0020086,Date:08/28/2014
LOAD CASE(S) Standard
�1 M.
.��`�•- LICENSE�� m
r N0.42704
s STATE OF :e�
.<A R1V�.•'tiw
s�NAt��
William M. Ranieri, P c # 42704
Job I russ ntss ype
> No on
728316 FC Floor 1 1
American Builder's Supply,Sanford,FL 32771 Job Reference(optional)
Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 M7ek Industries,Inc.Thu Aug 2815:31:15 2014 Pap
ID:cBA3zpKbMfNUP?GwJa8Yk9zZjN-8xU F6GMiG99?2MCOOyWuzCSS_OByLsCXuDX7hAyjHxw
2-6-0 1 6 6
i
Scale:1/2"=1'
Dead Load Defl.=1/8 in
3x4 11 3x6= 2x4 11 2x4 11 3x6= 3x4 11
1 2 3 43x4— 5 6 7
ELI E 1 Y
04
11 10 9 8
3x6— 4x4= 2x4 II 3x8= 3x6=
54-8 01a 14-10-14
54-8 00 0
B-0-0
Plate Offsets(X,Y)— [1:Edge 0-1-8] [3:0-1-8 Edge] [4:0-1-8 Edge] [10:0-1-8 0-0-0] [11:0-1 1:0-",Edge]
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP
TCLL 40.0 Plates Increase 1.00 TC 0.79 Vert(LL) -0.22 9-10 >799 360 MT20 244/190
TCDL 10.0 Lumber Increase 1.00 BC 0.77 Vert(TL) -0.33 9-10 >537 240
BCLL 0.0 Rep Stress Incr YES WB 0.53 Horz(TL) 0.04 8 n/a n/a
BCDL 10.0 Code FBC2010/TP12007 (Matrix) Weight:76 Ib FT=20%F,11%E
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 5-3-4 oc purlins, except
BOT CHORD 2x4 SP M 30(flat) end verticals.
WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (Ib/size) 12=879/0-6-0 (min.0-1-8),8=879/Mechanical
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 2-3=-2575/0,3-4=-2575/0,4-5=-2535/0,5-6=-2535/0
BOT CHORD 11-12=0/1596,10-11=0/2575,9-10=0/2575,8-9=0/1587
WEBS 6-8=-1747/0,2-12=-1757/0,6-9=0/1048,2-11=0/1107,5-9=-311/0,3-11=-279/0,4-9=-391/214
NOTES- (5)
1)Unbalanced floor live loads have been considered for this design.
2)Refer to girder(s)for truss to truss connections.
3)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to
be attached to walls at their outer ends or restrained by other means.
5)Segn:AO020087,Date:08/28/2014
LOAD CASE(S) Standard
�ANz
��`'--LICENSE r
N0.42704
i STATE 8F
mss........•��'
William M. Ranieri, P c # 42704
Job cuss nus me
7 } a+9 No 079
728315 FG1 FLOOR 1
2 Job Reference o ' nal
American Builders Supply,Sanford,FL 32771 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 Mfrek Industries,Inc.Thu Aug2815:31:16 2014 Page 1
ID:c8A3zpKbMfNUP?GwJa8Yk9zZbN-c72dJcML1 THsf WnCyg27WP?J30Vr4Fwh6tGgEdyan-v
2-2-14 4-4-1 6-5-3 8_r-5 10-7-7 12 8 10 1411 8
2-2-14 2-1-2 2-1-2 2-1-2 2-1-2 2-1-2 2-2-14
Scale=1:24.4
Dead Load Defl.=1/4 in
2x4 11 410= 2x4 11 3x8= 2x4 11 600= 3x4 11
1 302 2 3 4 5 6 7 g
W W 11 W1
1
17 15 18 14 19 13 20 12 21 22 11 23 10 24 9
3x8 I 4x12= HHUS46 2x4 11 HHUS46 300= HHUS46 2x4 11 600= HUS262x4 11 4x8=
HHUS46 HHUS46 Special HUS26
HUS26
0¢12 2-2-14 4 4 1 6 5 3 B 6 5 10-7-7 12 8'011_8
11-8
12 2-2-2 2-1-2 2-1-2 2-1-2 2-1-2 2-1-2 2-2-14
Plate Offsets(X,Y)- [15:0-5-8,07270]
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP
TCLL 40.0 Plates Increase 1.00 TC 0.64 Vert(LL) -0.2312-13 >764 360 MT20 244/190
TCDL 10.0 Lumber Increase 1.00 BC 0.73 Vert(TL) -0.4812-13 >361 240
BCLL 0.0 Rep Stress Incr NO WB 0.82 Horz(TL) 0.06 9 n/a n/a
BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:168 Ib FT=20%
LUMBER- BRACING-
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 3-6-14 oc purlins, except
BOT CHORD 2x6 SP 240OF 2.0E end verticals.
WEBS 2x4 SP No.3*Except* BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
EV1:2x6 SP No.2,W1,W3,W5,W7,W9,W1 1,W1 3:2x4 SP No.2
REACTIONS. (Ib/size) 9=4056/Mechanical,16=3419/0-3-9 (min.0-1-8)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 1-16=-2821/0,1-2=-5878/0,2-3=-5878/0,3-4=-12816/0,4-5=-12816/0,5-6=-11707/0,6-7=-11707/0,7-8=-418/0,
8-9=-295/0
BOT CHORD 16-17=0/650,15-17=0/650,15-18=0/10860, 14-18=0/10860,14-19=0/10860,13-19=0/10860,13-20=0/14218.
12-20=0/14218,12-21=0/14218,21-22=0/14218,11-22=0/14218, 11-23=0/7241,10-23=0/7241,10-24=0/7241,
9-24=0/7241
WEBS 1-15=0/5791,2-15=-279/0,3-15=-5478/0,3-14=0/845,3-13=0/2150,4-13=-298/0,5-13=-1543/0,5-12=0/1231,
5-11=-2762/0,6-11=-296/0,7-11=0/4911,7-10=0/642,7-9=-7502/0
NOTES- (12)
1)2-ply truss to be connected together with 10d(0.131"x3")nails as follows:
Top chords connected as follows:2x6-2 rows staggered at 0-9-0 oc,2x4-1 row at 0-7-0 oc.
Bottom chords connected as follows:2x6-2 rows staggered at 0-9-0 oc.
Webs connected as follows:2x4-1 row at 0-9-0 oc.
2)All loads are considered equally applied to all plies,except if noted as front(F)or back(B)face in the LOAD CASE(S)section.Ply to ply
connections have been provided to distribute only loads noted as(F)or(B),unless otherwise indicated.
3)Refer to girder(s)for truss to truss connections.
4)Provide metal plate or equivalent at bearing(s)9 to support reaction shown.
5)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
6)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to
be attached to walls at their outer ends or restrained by other means.
7)Use Simpson Strong-Tie HHUS46(14-10d Girder,6-10d Truss,Single Ply Girder)or equivalent spaced at 2-0-0 oc max.starting at
1-8-12 from the left end to 8-11-12 to connect truss(es)F4(1 ply 2x4 SP),F5(1 ply 2x4 SP)to front face of bottom chord.
8)Use Simpson Strong-Tie HUS26(14-10d Girder,4-10d Truss,Single Ply Girder)or equivalent spaced at 2-0-0 oc max.starting at
10-7-12 from the left end to 14-3-4 to connect truss(es)FT4(1 ply 2x4 SP),FT3(1 ply 2x4 SP),FT2(1 ply 2x4 SP)to front face of bottom
chord.
9)Fill all nail holes where hanger is in contact with lumber.
10)WARNING:The following hangers are manually applied but fail due to geometric considerations:HUS26 on front face at 10-7-12 from
the left end. � ...�•
11 Hanger(s)or other connection devices shall be provided sufficient to support ���
( ) p pport concentrated load(s)514 Ib down at 10-2-4 on bottom .•
chord. The design/selection of such connection device(s)is the responsibility of others. �,AZZQ>�!_�I.ENSE
12)Segn:A0020089,Date:08/28/2014
e ►•� z~
i
LOAD CASEN0.42704S) Standard * �
Continued on page 2 i ^
STATE OF
.(4RIO 6.0 tv
NAI.ti
William M. Ranieri, P c # 42704
Job russ Tnuss ype Qty ply -.--
' Dwg No 080
728315 FG2 FLOOR 1
3 Job Reference(optional)
American Builders supply,Sanford,FL771 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 M7ek Industries,Inc. Thu—Aug 2815:31:17 2014 Page 1
ID:c8A3zpKbMfN UP?GwJa8Yk9zZtN-4Kb?XxNzonQjHfMOVNZM2dX�S4gpMphugLXOEm3y/Hxu
1-5-0 3-7-12 5-8-12 7-9-12 s 10 12 12-1.8
1-5-0 2-2-12 2-1-0 2-1-0 2-1-0 2-2-12
Scale=1:19.7
Dead Load Dell.=1/8 in
2x4 11 3x8= 2x4 11 2x4 11 3x4= 3x6=
1 3x6 2 3 4 5 6 15 7
EV1 W1 W2 W3 W4 W6 W91 11
B2 Ri
HHUS26-2
14 12 11 10 16 9 5x6—
2x4 I I 2x4 11 2x4 11 8x8=
4x12=
3x4 11
1-2-0 3-7-12 5-8-12 7-9-12 9-10-12 12-1-7 12 1-8
1-2-0 2-2-12 2-1-0 2-1-0 _ 2-1-0 2-2-11 1
Plate Offsets(X,Y)` [3:0-3-8,0-1-8],[10:0-3-8,Edge]
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP
TCLL 40.0 Plates Increase 1.00 TC 0.75 Vert(LL) -0.17 10-11 >731 360 MT20 244/190
TCDL 10.0 Lumber Increase 1.00 BC 0.84 Vert(TL) -0.31 10-11 >407 240
BCLL 0.0 Rep Stress Incr NO WB 0.84 Horz(TL) 0.03 8 n/a n/a
BCDL 10.0 Code FBC2010lfP12007 (Matrix-M) Weight:174 Ib FT=20%
LUMBER- BRACING-
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
BOT CHORD 2x6 SP No.2`Except* end verticals.
132:2x4 SP M 31 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3*Except*
EV1:2x6 SP No.2,W9,W11:2x4 SP Not
REACTIONS. (Ib/size) 8=3522/0-6-1 (min.0-1-8),13=5776/0-6-0 (min.0-1-10)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 1-2=0/474,2-3=0/474,3-4=-9576/0,4-5=-9576/0,5-6=-9325/0,6-15=-6761/0,7-15=-6761/0,7-8=-3164/0
BOT CHORD 12-13=0/9576,11-12=0/9576,10-11=0/9576, 10-16=0/6773,9-16=0/6780,8-9=0/369
WEBS 1-13=-656/0,2-13=-1187/0,3-13=-11013/0,3-12=0/1440,4-11=-846/0,5-10=-1810/0,6-10=0/3068,6-9=-2673/0,
7-9=0/7038
NOTES- (9)
1)3-ply truss to be connected together with 10d(0.131"x3")nails as follows:
Top chords connected as follows:2x6-2 rows staggered at 0-9-0 oc,2x4-1 row at 0-9-0 oc.
Bottom chords connected as follows:2x4-1 row at 0-9-0 oc,2x6-2 rows staggered at 0-9-0 oc.
Webs connected as follows:2x4-1 row at 0-9-0 oc.
2)All loads are considered equally applied to all plies,except if noted as front(F)or back(B)face in the LOAD CASE(S)section.Ply to ply
connections have been provided to distribute only loads noted as(F)or(B),unless otherwise indicated.
3)Unbalanced floor live loads have been considered for this design.
4)The Fabrication Tolerance at joint 10=12%
5)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
6)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to
be attached to walls at their outer ends or restrained by other means.
7)Use Simpson Strong-Tie HHUS26-2(14-10d Girder,4-10d Truss)or equivalent at 9-3-7 from the left end to connect truss(es)FG3(2 ply
2x6 SP)to front face of bottom chord.
8)Fill all nail holes where hanger is in contact with lumber.
9)Segn:A0020090,Date:08/28/2014
LOAD CASE(S) Standard
1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00
Uniform Loads(plf)
Vert:1-6=-880,6-7=-208,8-14=-20
Concentrated Loads(lb) ...
Vert:16=-121(F) �`�� `LICENSE m
^ .
No.42704 5
STATE OF '4�
r
ss�oNA�.ti'��
William M. Ranieri, P c It 42704
ocuss was Type
• ' Dwg No 082
2
728315 FG4 FLOOR 1 Job Reference o tional
American Builder's Supply,Sanford,FL 32771 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 Mi-rek Industries,Inc. Thu Aug 2815:31:18 2014 Pale 1
I D:cBA3zpKbMfN UP?GwJa8Yk9zZ]j N-Y W9OkHObZ4Yavpwb354bbg4a_D7BY7A_aBIn IVY1Hxt
3-2-13 6 3 15 9 5-0 12$1 15-7-3 18-10-0
3-2-13 3-1-1 3 1-1 3-1-1 3-1-1 1 3-2-13
Scale=1:30.9
Dead Load Def.=11/16 in
54= 4x4= 2x4 II 4x4= 3x6= 5x6= 6x6=
16x6 2 3 4 5 6 7 8
"It
16 17 14 18 13 19 12 20 11 21 10 22 23 9
4x4 11 HUS26 7x8 HUS26 8x8= HUS26 4x8— 5x6= HUS26 6x6= 4x4
HUS26 HUS26 HUS26 HUS26 HUS26 HUS26
3 2-13 6 3 15 9-5-0 I 12$1 77-3 18-10-0
3-2-13 3 1-1 3-1-1 3 1-1 3-1-1 3-2-13
Plate Offsets(X,Y)- [9:Edge 0-3-8],[13:0-4-0,0-5-0],[14:0-3-8,0-3-8]
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP
TCLL 40.0 Plates Increase 1.00 TC 0.93 Vert(CIL) -0.20 12 >999 360 MT20 244/190
TCDL 10.0 Lumber Increase 1.00 BC 1.00 Vert(TL) -0.89 12 >250 240
BCLL 0.0 Rep Stress Incr NO WB 0.83 Horz(TL) 0.05 9 n/a n/a
BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:207 Ib FT=20%
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-2-5 oc purlins, except
BOT CHORD 2x6 SP No.2*Except* end verticals.
B2:2x6 SP 240OF 2.0E BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.2*Except*
EV1:2x6 SP No.2,EV2,W20406,W8010:2x4 SP No.3
REACTIONS. (Ib/size) 15=2489/0-5-4 (min.0-1-8),9=2469/Mechanical
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown.
TOP CHORD 1-15=-2064/0,1-2=-6085/0,2-3=-9889/0,3-4=-10569/0,4-5=-10569/0,5-6=-9818/0,
6-7=-9818/0,7-8=-6077/0,8-9=-2054/0
BOT CHORD 15-16=0/585,16-17=0/585,14-17=0/585,14-18=0/6085,13-18=0/6085,13-19=0/9890,
12-19=0/9890,12-20=0/9818,11-20=0/9818,11-21=0/6077,10-21=0/6077,10-22=0/438,
22-23=0/438,9-23=0/438
WEBS 1-14=0/5772,2-14=-1654/0,3-13=-763/0,3-12=0/710,4-12=486/0,5-12=0/786,
5-11=-778/0,7-10=-1661/0,8-10=0/5904,2-13=0/3983,7-11=0/3917
NOTES- (9)
1)2-ply truss to be connected together with 10d(0.131"x3")nails as follows:
Top chords connected as follows:2x6-2 rows staggered at 0-9-0 oc,2x4-1 row at 0-7-0 oc.
Bottom chords connected as follows:2x6-2 rows staggered at 0-9-0 oc.
Webs connected as follows:2x4-1 row at 0-9-0 oc.
2)All loads are considered equally applied to all plies,except if noted as front(F)or back(B)face in the LOAD CASE(S)section.Ply to ply
connections have been provided to distribute only loads noted as(F)or(B),unless otherwise indicated.
3)The Fabrication Tolerance at joint 6=20%
4)Refer to girder(s)for truss to truss connections.
5)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
6)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to
be attached to walls at their outer ends or restrained by other means.
7)Use Simpson Strong-Tie HUS26(14-10d Girder,4-10d Truss,Single Ply Girder)or equivalent spaced at 2-0-0 oc max.starting at 1-0-0
from the left end to 18-2-8 to connect truss(es)FT1 (1 ply 2x4 SP)to back face of bottom chord.
8)Fill all nail holes where hanger is in contact with lumber.
9)Segn:A0020092,Date:08/28/2014
LOAD CASE(S) Standard
1)Dead+Floor Live(balanced):Lumber Increase=1-00,Plate Increase=1.00 ,...,••�� /
Uniform Loads(plf)
Vert:1-8=-172,9-15=-20 , �. . LICENSE •;�
Concentrated Loads(lb) �
Vert:13=-141(B)11=-141(B)16=-141(8)17=-141(B)18=-141(B)19=-141(B)20=-141(B)21=-141(B)22=-141(8)23=-141(B) s No.42704
•It.
•
STATE OF
ass......,
William M. Ranieri, P c # 42704
Truss russ ype
� Dwg No 084
728315 FT1 ROOF SPECIAL 10 1
Qty Job Reference(optional)
American Builder's Supply,Sanford,FL 32771 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MTek Industries,Inc.Thu Aug 2815:31:19 2014 Page 1
ID:c8A3zpKbMfN UP?GWJa6Yk9zZ)jN-0ijmydPDKOgRWzVndobg82doMdZbHfP7orVKgxyj Hxs
5-0-4 6-1-0 7-5-0
5-04 1-0-12 1-4-0
Scale=1:13.6
Dead Load Defl.=1/16 in
0.13 L2
7x6 zz
1 2x4 11
10 2 3.00112
3
W1 �7j T2 W2
4
B1
4x4= 5
6
3x4=
5 0 4 6-1-0
5-0-4 1 0 12
Plate Offsets(X,Y)- [2:0-1-12,0-1-8]
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP
TCLL 60.0 Plates Increase 1.00 TC 0.76 Vert(LL) -0.03 5-6 >999 240 MT20 244/190
TCDL 10.0 Lumber Increase 1.00 BC 0.60 Vert(TL) -0.09 5-6 >780 180
BCLL 0.0 ' Rep Stress Incr NO WB 0.51 Horz(TL) 0.01 3 n/a n/a
BCDL 10.0 Code FBC2010[TP12007 (Matrix-M) Weight:28 Ib FT=20%
LUMBER- BRACING- --
TOP CHORD 2x4 SP M 30*Except* TOP CHORD Structural wood sheathing directly applied or 5-0-4 oc purlins, except
T2:2x4 SP No.2 end verticals.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3 MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection,in accordance with Stabilizer
Installation uide.
REACTIONS. (Ib/size) 6=521/Mechanical,3=991/0-6-0 (min.0-1-8)
Max Horz 6=-34(LC 12)
Max Uplift6=-28(LC 8)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 1-6=-341/145,2-3=-1245/0
BOT CHORD 5-6=0/1085,3-5=0/1117
WEBS 2-6=-1092/0
NOTES- (9)
1)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf;BCDL=4.2psf;h=15ft;B=45ft;L=24ft;eave=oft;Cat.11;
Exp C;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)0-1-12 to 3-1-12,Interior(1)3-1-12 to 7-5-7 zone;cantilever left and
right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60
2)Provide adequate drainage to prevent water ponding.
3)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5)Refer to girder(s)for truss to truss connections.
6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 28 Ib uplift at joint 6.
7)Load case(s)1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,17,18,19,20 has/have been modified.Building designer must review
loads to verify that they are correct for the intended use of this truss.
8)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
9)Segn:A0020094,Date:08/28/2014
LOAD CASE(S) Standard
1)Dead+Roof Live(balanced):Lumber Increase=1.00,Plate Increase=1.00
Uniform Loads(plf)
Vert:1-2=-140,2-4=-140,6-7=-20
Concentrated Loads(Ib) 11w M■
Vert:2=-376 •.••�• ••.••"�YA�
2)Dead+0.75 Roof Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 `LICEfV3E• m
Uniform Loads(plf) .• A
Vert:1-2=-110,2-4=-110,6-7=-20 : ;•-
No.4Z704
Continued on page 2 • _.
STATE OF
William M. Ranieri, P c # 42704
o russ Truss Type
� Dwg No 084
728315 I Frt ROOF SPECIAL 10 1
Job Reference o tional)
American Builders Supply,Sanford,FL 32771 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc.Thu Aug 28 15:31:19 2014 Page 3
ID:c8A3zpKbMfNUP?G vJa8Yk9zZJ1N-0ijmydPDKOgRWzVndobg82doMdZbHfP7orVKgxyjHxs
LOAD CASE(S) Standard
Concentrated Loads(lb)
Vert:2=-263
16)Dead:Lumber Increase=0.90,Plate Increase=0.90 Plt.metal=0.90
Uniform Loads(plf)
Vert:1-2=-20,2-4=-20,6-7=-20
Concentrated Loads(lb)
Vert:2=-256
17)Dead+0.75 Roof Live(bal.)+0.75(0.6 MWFRS Wind(Neg.Int)Left):Lumber Increase=1.60,Plate Increase=1.60
Uniform Loads(plf)
Vert:1-2=-111,2-3=-102,3-4=-97,6-7=-20
Horz:1-2=-1,2-3=8,3-4=13
Concentrated Loads(lb)
Vert:2=-351
18)Dead+0.75 Roof Live(bal.)+0.75(0.6 MWFRS Wind(Neg.Int)Right):Lumber Increase=1.60,Plate Increase=1.60
Uniform Loads(plf)
Vert:1-2=-111,2-3=-111,3-4=-106,6-7=-20
Horz:1-2=-1,2-3=-1,3-4=4
Concentrated Loads(lb)
Vert:2=-351
19)Dead+0.75 Roof Live(bal.)+0.75(0.6 MWFRS Wind(Neg.Int)1st Parallel):Lumber Increase=1.60,Plate Increase=1.60
Uniform Loads(plf)
Vert:1-2=-111,2-3=-111,3-4=-106,6-7=-20
Horz:1-2=-1,2-3=-1,3-4=4
Concentrated Loads(lb)
Vert:2=-351
20)Dead+0.75 Roof Live(bal.)+0.75(0.6 MWFRS Wind(Neg.Int)2nd Parallel):Lumber Increase=1.60,Plate Increase=1.60
Uniform Loads(plf)
Vert:1-2=-111,2-3=-111,3-4=-106,6-7=-20
Horz:1-2=-1,2-3=-1,3-4=4
Concentrated Loads(lb)
Vert:2=-351
' LICENSE'•• m
No.42704
i STATE OF
<O Rtpp'`'���k'
�NAI���'
William M. Ranieri, P c # 42704
o ruse cuss ype
•. s Dxg No 086
728315 FT2 FLOOR 1 1
Job Referyence(optional) 014 g
American Builders Supply,Sanford,Ft 32771 Run: A= e 1
�UP Print:
GwJa8Yk9zZhN-0ij ydPDKOg WiVndobg82Inc.Thu drtdb4Hek728 15:31:19orVKgxyiHxs
4-3-14 8-10-12
4-3-14 4-6-14
2x4 11 Scale=1:20.0
1 5x6— 2 4x4— 3
W5 W3 EW Y
EV1 B2 4x6= 4
4x4=
7 34 6
2x4 11
4-3-14 8-10-12
4-3-14 4-6-14
Plate Offsets(),Y)— [5:0-5-12,0-2-8]
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl UdPLATES GRIP
TCLL 40.0 Plates Increase 1.00 TC 0.54 Vert(LL) -0.06 5 >999 360 MT20 244/190
TCDL 10.0 Lumber Increase 1.00 BC 0.51 Vert(TL) -0.11 4-5 >960 240
BCLL 0.0 Rep Stress Incr YES WB 0.62 Horz(TL) 0.07 4 n/a n/a
BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight:54 Ib FT=20%
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-8-0 oc purlins, except
BOT CHORD 2x4 SP No.2*Except* end verticals.
B2:2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3 MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection,in accordance with Stabilizer
Installation guide.
REACTIONS. (Ib/size) 7=516/Mechanical,4=516/Mechanical
FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 1-7=-45710,1-2=-1266/0
BOT CHORD 4-5=0/1348
WEBS 2-4=-1382/0,1-5=0/1300
NOTES- (4)
1)Refer to girder(s)for truss to truss connections.
2)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to
be attached to walls at their outer ends or restrained by other means.
4)Segn:A0020096,Date:08/28/2014
LOAD CASE(S) Standard
LICENSE •;���
�►:• No.42704
STATE 8F e�
NAIti
William M. Ranieri, P c # 42704
cuss Tnjw Type Qty Ply
fheg No 088
728315 FT4 FLOOR 1 1
Job Reference(optional)
nrtrenpn embers Supply,Sanford,FL 32771 Run:7.520 5 May�8 2014 Font:7.520 s May 8 2014 MTek Industries,Inc.Thu Aug 28 15:31:20 2014 Page 1
ID:c8A3zpKbMfNUP?GwJa8Yk9z4N-UvH89zPr5io1874zBW63gF9131 s80AIG 1 VEuNOyj Hxr
4-4-7 8-8-14 8-1-14
-1-
44-7 4-4-7 0-5-0'
2x4 11 3x8= 2x4 11 Scale=1:20.0
1 2 3
EVt W2
Id
7 U4— 6 5
2x4 11 3x4=
4-4-7 _ 84-14 -14
4-4-7 4-4-7 ola
LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) I/deft L/d PLATES GRIP
TCLL 40.0 Plates Increase 1.00 TC 0.51 Vert(LL) -0.04 5-6 >999 360 MT20 244/190
TCDL 10.0 Lumber Increase 1.00 BC 0.71 Vert(TL) -0.09 5-6 >999 240
BCLL 0.0 Rep Stress Incr YES WB 0.32 Horz(TL) 0.01 4 n/a n/a
BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:53 Ib FT=20%
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 8-8-14 oc purlins, except
BOT CHORD 2x4 SP No.2 end verticals.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection,in accordance with Stabilizer
Installation guide.
REACTIONS. (Ib/size) 4=492/0-4-0 (min.0-1-8),7=530/Mechanical
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
BOT CHORD 6-7=0/481,5-6=0/481
WEBS 2-7=-593/0,2-5=-593/0
NOTES- (4)
1)Refer to girder(s)for truss to truss connections.
2)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to
be attached to walls at their outer ends or restrained by other means.
4)Segn:A0020098,Date:08/28/2014
LOAD CASE(S) Standard
��`�;'�LICENSE�•;�
N0.42704
STATE OF
0 F10
William M. Ranieri, P # 42704
Job Truss Truss Type
1• r Dwg No 089
728315 FTA4 HALF HIP GIRDER 1City Ply 2 Job Reference(optional)
`` American Builder's Supply,Sanford,FL 32771 Run:7520 5 MaYy 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Thu Aug 28 15:31:22 2014 Page 1
I D:c8A3zpKbMfNUP?GwJa8Yk9zZb.N-RHPuafR5cJ2?NREMlw8XIgFJaraCU?DZVpj_RGyjHxp
1�0 3�-0 5 7-0 7-10-0 11SF 15-5-0 19 1-10 23-0-0
1 4 0 ' 3�0 23-0 2-3 0 3 10 6 3-8-10 3 8 10 3-10.6
Scale=1:39.8
Dead Load Defl.=12 in
NAILED
3.00 F12 NAILED
5x8— NAILED 4x4= 2x4 11 5x8= 2x4 11 5x6=
3 78 19 4 5 20 6 7 8
2 —
14 21 22 13 12 11 10 9
3x6= 2x4 1 i NAILED 5x6= 7x8= 2x4 11 5x10= 3x4 11
NAILED HHUS26-2
NAILED
3�U 7-10-0 11 8 6 15-5 0 19-1-10 23-0-0
3 4 0 4-6-0 3-10-0 3-&10 348110 3-10-0
Plate Offsets(X,Y)- [2:0-4-3,0-0-31,[3:0-6 00-2-0] [6:0-4-0,0-3-0],[12:0-4-0,0-5-01
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP
TCLL 40.0 Plates Increase 1.00 TC 0.76 Vert(LL) -0.4012-13 >679 240 MT20 244/190
TCDL 10.0 Lumber Increase 1.00 BC 0.61 Vert(TL) -0.94 12-13 >293 180
BCLL 0.0 ' Rep Stress Incr NO WB 0.64 Horz(TL) 0.06 9 n/a n/a
BCDL 10.0 Code FBC2010ITP12007 (Matrix-M) Weight:245 Ib FT=20%
LUMBER- BRACING-
TOP CHORD 2x4 SP No.3'Except' TOP CHORD Structural wood sheathing directly applied or 4-1-5 oc purlins, except
T2:2x4 SP M 30,T3:2x4 SP No.2 end verticals.
BOT CHORD 2x6 SP 240OF 2.0E BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3*Except*
W3,W7,W9,W11:2x4 SP Not
REACTIONS. (Ib/size) 9=1561/0-6-0 (min-0-1-8),2=1931/0-6-0 (min.0-1-8)
Max Hoa 2=48(LC 25)
Max Uplift9=-153(LC 5),2=-158(LC 8)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 2-3=-5688/178,3-18=-9875/150,18-19=-9875/150,4-19=-9875/150,4-5=-9546/420,
5-20=-9546/420,6-20=-9546/420,6-7=-4628/390,7-8=-4628/390,8-9=-1315/144
BOT CHORD 2-14=-183/5486,14-21=-170/5514,21-22=-170/5514,13-22=-170/5514,12-13=-1 50/9875,
11-12=-571/8411,10-11=-571/8411,9-10=-42/369
WEBS 3-13=0/4519,4-13=-792/4,4-12=-770/423,5-12=-333/111,6-12=0/1476,6-11=0/268,
6-10=-3906/197,7-10=-331/119,8-10=-359/4399
NOTES- (15)
1)2-ply truss to be connected together with 1 Od(0.131"x3")nails as follows:
Top chords connected as follows:2x4-1 row at 0-7-0 oc.
Bottom chords connected as follows:2x6-2 rows staggered at 0-9-0 oc.
Webs connected as follows:2x4-1 row at 0-9-0 oc.
2)All loads are considered equally applied to all plies,except if noted as front(F)or back(B)face in the LOAD CASE(S)section.Ply to ply
connections have been provided to distribute only loads noted as(F)or(B),unless otherwise indicated.
3)Unbalanced roof live loads have been considered for this design.
4)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf;BCDL=4.2psf;h=15ft;B=45ft;L=24ft;eave=4ft;Cat.11;
Exp C;Encl.,GCpi=0.18;MWFRS(directional);cantilever left and right exposed;Lumber DOL=1.60 plate grip DOL=1.60
5)Provide adequate drainage to prevent water ponding.
6)Plate(s)at joint(s)12 checked for a plus or minus 2 degree rotation about its center.
7)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
9)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 153 Ib uplift at joint 9 and 158 Ib uplift at joint
2. �1 Ma
10)Load case(s)1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16,21,22,23,24,25,26,27,28,29,30,31,32 has/have been modified. ���,..•.+..
Buildingdesigner must review loads to verifythat the are correct for the intended use of this truss. •' .
11)"Semi-rigid it
gid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss. LICENSE '•
12)Use Simpson Strong-Tie HHUS26-2(14-1OdGirder,4-1 Od Truss)or equivalent at 7-11-9 from the left end to connect truss(es)FGC V-
ply 2x6 SP)to back face of bottom chord. No.42704
13)Fill all nail holes where hanger is in contact with lumber.
14)"NAILED"indicates 3-1 Od(0.148"x3")or 2-12d(0.148"x3.25")toe-nails.For more details refer to MiTek's ST-TOENAIL Detail.
Continued on page 2 ? STATE OF
0R1p6.•'k�
��NAI.ti�
William M. Ranieri, P c # 42704
�FTA4
s mss Type
--JQ
---
028315 No 089
728315 HALF HIP GIRDER 1
V7__ 2 Job Reference(optional)
American Builders Supply,Sanford,FL 32771 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc.Thu Aug 2815:31:22 2014 Paggee 3
ID:c8A3zPKbMfNUP?GwJa8Yk9z4.N-RHPuafR5cJ2?NREM IwBXIgFJaraCU?DZVpj_RGyjHxp
LOAD CASE(S) Standard
Uniform Loads(plf)
Vert:1-2=-67,2-3=-72,3-8=-81,9-15=-20
Horz:1-2=-13,2-3=-8
Concentrated Loads(lb)
Vert:4=-325 18=119(B)19=48(B)21=11(8)22=4(B)
15)Dead+0.75 Roof Live(bal.)+0.75(0.6 MWFRS Wind(Neg.Int)1st Parallel):Lumber Increase=1.60,Plate Increase=1.60
Uniform Loads(plf)
Vert:1-2=-76,2-3=-81,3-8=-81,9-15=-20
Horz:1-2=4,2-3=1
Concentrated Loads(lb)
Vert:4=-325 18=119(B)19=48(B)21=11(B)22=4(B)
16)Dead+0.75 Roof Live(bal.)+0.75(0.6 MWFRS Wind(Neg.Int)2nd Parallel):Lumber Increase=1.60,Plate Increase=1.60
Uniform Loads(plf)
Vert:1-2=-76,2-3=-81,3-8=-81,9-15=-20
Horz:1-2=4,2-3=1
Concentrated Loads(lb)
Vert:4=-325 18=119(B)19=48(B)21=11(B)22=4(B)
21)Reversal:Dead+0.6 MWFRS Wind(Pos.Internal)Left:Lumber Increase=1.60,Plate Increase=1.60
Uniform Loads(plf)
Vert:1-2=43,2-3=24,3-19=30,19-20=25,8-20=16,9-15=-8
Horz:1-2=-52,2-3=-33
Concentrated Loads(lb)
Vert:4=-210 18=-173(B)19=-72(8)21=-76(B)22=-32(B)
22)Reversal:Dead+0.6 MWFRS Wind(Pos.Intemal)Right:Lumber Increase=1.60,Plate Increase=1.60
Uniform Loads(plf)
Vert:1-2=8,2-3=15,34=16,4-6=25,6-8=30,9-15=-8
Horz:1-2=-17,2-3=-24
Concentrated Loads(lb)
Vert:4=-210 18=-139(B)19=-58(8)21=-76(B)22=-32(B)
23)Reversal:Dead+0.6 MWFRS Wind(Neg.Internal)Left:Lumber Increase=1.60,Plate Increase=1.60
Uniform Loads(plf)
Vert:1-2=-14,2-3=-21,3-8=-21,9-15=-20
Horz:1-2=-6,2-3=1
Concentrated Loads(lb)
Vert:4=-272 18=-50(B)19=-21(B)21=-48(B)22=-20(B)
24)Reversal:Dead+0.6 MWFRS Wind(Neg.Internal)Right:Lumber Increase=1.60,Plate Increase=1.60
Uniform Loads(plf)
Vert:1-2=-3,2-3=-10,3-8=-21,9-15=-20
Horz:1-2=-17,2-3=-10
Concentrated Loads(lb)
Vert:4=-272 18=-50(B)19=-21(B)21=-48(8)22=-20(B)
25)Reversal:Dead+0.6 MWFRS Wind(Pos.Internal)1st Parallel:Lumber Increase=1.60,Plate Increase=1.60
Uniform Loads(plf)
Vert:1-2=46,2-3=27,3-8=27,9-15=-8
Horz:1-2=-54,2-3=-35
Concentrated Loads(lb)
Vert:4=-213 18=-166(B)19=-69(B)21=-76(8)22=-32(B)
26)Reversal:Dead+0.6 MWFRS Wind(Pos.Internal)2nd Parallel:Lumber Increase=1.60,Plate Increase=1.60
Uniform Loads(plf)
Vert:1-2=27,2-3=8,3-8=8,9-15=-8
Horz:1-2=-35,2-3=-16
Concentrated Loads(Ib)
Vert:4=-230 18=-119(B)19=-50(8)21=-76(B)22=-32(B)
27)Reversal:Dead+0.6 MWFRS Wind(Neg.Internal)1st Parallel:Lumber Increase=1.60,Plate Increase=1.60
Uniform Loads(plf)
Vert:1-2=-14,2-3=-21,3-8=-21,9-15=-20
Hoa:1-2=-6,2-3=1
Concentrated Loads(lb)
Vert:4=-272 18=-50(B)19=-21(B)21=48(B)22=-20(B)
28)Reversal:Dead+0.6 MWFRS Wind(Neg.Internal)2nd Parallel:Lumber Increase=1.60,Plate Increase=1.60
Uniform Loads(plf)
Vert:1-2=-14,2-3=-21,3-8=-21,9-15=-20
Horz:1-2=-6,2-3=1
Concentrated Loads(lb)
Vert:4=-272 18=-50(B)19=-21(B)21=-48(B)22=-20(B)
29)Reversal:Dead+0.75 Roof Live(bal.)+0.75(0.6 MWFRS Wind(Neg.Int)Left):Lumber Increase=1.60,Plate Increase=1.60
Uniform Loads(plf)
Vert:1-2=-76,2-3=-81,3-8=-81,9-15=-20
Horz:1-2=4,2-3=1
Concentrated Loads(lb)
Vert:4=-325 18=14(6)19=5(B)21=-57(B)22=-24(B)
30)Reversal:Dead+0.75 Roof Live(bal.)+0.75(0.6 MWFRS Wind(Neg.Int)Right):Lumber Increase=1.60,Plate Increase=1.60 �A
Uniform Loads(plf) ■
Vert:1-2=-67,2-3=-72,3-8=-81,9-15=-20 ���..•""'••.
Horz:1-2=-13,2-3=-8 `LICENSE••• m
Concentrated Loads(lb)
Vert:4=-325 18=14(B)19=5(B)21=-57(B)22=-24(B) ;• No.42704 •'
Continued on page 4 ,� •
STATE OF
William M. Ranieri, P c # 42704
Nss w
as Type Qly ply
r Dag No 091
728315 FX Supported Gable 1 1
.Inh Reference/nMinnall
American Builders Supply,Sanford,FL 32771 Run:7.520 s May 8 2014 Print.7.520 s May 8 2014 M7ek Industries,Inc.Thu Aug 2815:31:23 2014 ppaagyea 1
ID:c8A3zpKb MfN U P?GwJa8Yk9zZIjN-vUzH n?SkNdAs?a pYsegm luneO E3cDbxbTTYzjAHxo
OWI 8
Scale=1:326
34 FP=
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
Lj
1 5 8 S 0 S 1 2 S 3 4 S 5 1v
4 R2
36 35 34 33 32 31 30 29 28 27 25 25 24 23 22 21 20 19
3x4= 34 FP=
20-8-0
Plate Offsets(X,Y)— [18:0-1-8,Edge],[19:0-1-8,Edge],[37:0-1-8,0-1-0] 20 -0
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP
TCLL 40.0 Plates Increase 1.00 TC 0.08 Vert(LL) n/a n/a 999 MT20 244/190
TCDL 10.0 Lumber Increase 1.00 BC 0.02 Vert(TL) n/a n/a 999
BCLL 0.0 Rep Stress Incr YES WB 0.03 Horz(TL) 0.00 19 n/a n/a
BCDL 10.0 Code FBC2010/TP12007 (Matrix) Weight:90 Ib FT=20%F,11%E
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
BOT CHORD 2x4 SP No.2(flat) end verticals.
WEBS 2x4 SP No.3(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3(flat)
REACTIONS. All bearings 20-8-0.
(lb)- Max Grav All reactions 250 Ib or less at joint(s)36,19,35,34,33,31,30,29,28,27,26,25,24,23,22,21,
20
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown.
NOTES- (8)
1)All plates are 2x4 MT20 unless otherwise indicated.
2)Gable requires continuous bottom chord bearing.
3)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web).
4)Gable studs spaced at 1-4-0 oc.
5)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
6)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to
be attached to walls at their outer ends or restrained by other means.
7)CAUTION,Do not erect truss backwards.
8)Segn:AO020101,Date:08/28/2014
LOAD CASE(S) Standard
M.
LICENSE-..
No.42704
z STATE OF
r A �
a1.µal•
s
NAL��
William M. Ranieri, P c # 42704
VOLZb # d `ua!uea •w Lue!II!M
�4
,.para o�•y. 'X)s
y
V; :10 31VIS
VOLZV'ON of 9
�dso
�4,%3SN3011
.w
(9)L17-=SL(9)Lt1=17L(9)Ltr=£L(e)69-=ZL(e)8E-=LL(9)8E-=OL(9)8E-=69(9)8£-=89(S)1,LL-=L9(9)7LL-=99(e)17LL-=99(9)17LL-=179(9)LV-=E9(9)LtT-=Z9
(9)Lt-=L9(9)Lt-=09(94t-=69(e)69-=LS(9)69-=99(S)0£L-=99(9)OEL-=VS(9)OEL-=£S(e)LLL-=ZS(9)Z8-=LS(9)ZB-=0S(e)Z9-=6V(9)Z8=9V(9)L-=LV(e)L-=917
(9)L-=VV(9)L-=ZV(e)Z8-=LV(e)Z8-=04(e)Z9-=6£(9)Z8=L£(9)Ll l =9£(e)Ll l =S£(9)SLZ=Ll(9)LV-=9Z(9)Z8-=9(e)6LZ-=6Z(e)96L-=£L(9)Z8-=L(q))speo-1 pale auaouo0
OZ-91,-91,'OZ—OZ-61,'0Z-=9Z-L Z'OZ-=L£-LZ'09-=9 L-V L'09-=V L-£L'09-=E L-V'09-=tr L:yan
(;Id)speo-i iwo;!un
SZ'L=aseaJ0ul aleld'SZ'l=aseajoul jagwnj:(paoueleq)an!-1;o0a+pea❑(l,
piepuelS (S)3SV3 OVO-i
VLOZ/82/80 ale(]'l LOOZOOyubaS(OL
(e)Moeq jo(d)luo4 se palou aje ssrul ay110 a0e;aril 01 pa!ldde speol'uogoas(S)3SVO GVOI a41 ul(6
sjaylo;o/q!1!q!suodsaj ay1 s!(S)a0!nap uo!loauuoo yens;o uogoales/u6!sap ay. pioyo wolloq uo
V-6-LV le do ql SSE pue umop ql L6£Pue't-6-SV le umop ql 96 PUB't,6-EV le umop ql 96'tr6-1,17 le umop ql S6'V-6-6E le umop ql 99't-6-LE le umop ql LS 1-6-SE le umop
ql LS't-6-EE le umop ql LS't,-6-LE le umop ql LS't-6-6Z le do ql Eo I,pue umop ql t7L1,'t,-6-LZ le do q!EOL pue umop ql 17L 1,'Z 1,-0-LZ le do ql EOL pue umop ql YL L'Z L-O-SZ
le do ql EOL pue umop ql VLL'ZL-O-EZ 1e umop ql L9'ZL-0-1 Z le umop ql L9'ZL-0-61, le umop ql L9'ZL-0-1L le umop ql L9'Zl,-O-SL le umop ql L9'ZL-O-EI le umop ql L9
'ZL-O-L L le umop ql S8'ZL-0-6 le umop ql S8'0-0-L le do ql ZL pue umop ql 96Z Pue'pioyo dol uo O-OL-LV le do ql SV£pue umop gl l9Z PUe'tr6-S4 le do ql 06L pue umop
ql g9l,PUe'V-6-£V le do ql 061,pue umop ql 9SL'V-6-1,V le do ql 06L pue umop ql 9S L'V-6-6E le do ql ZZL pue umop ql 9cl,'t-6-L£ le do ql ZO L pue umop ql ZL L 17-6S£ le
do ql ZOL pue umop ql Z l L't,-6-EE le do qI ZOL pue umop ql ZL L'V-6-L£ le do ql ZO L pue umop ql ZL L'4-6-62 le do ql LE pue umop gI 9L'17-6-LZ le do qI L£pue umop ql 9L
'ZL-O-LZ le do ql l£pue umop q1 9L'Zl-O-SZ le do ql L£pue umop ql 9L'ZL-0-£Z 1e do ql ZOL pue umop q!ZL L 'Zl-O-IZ le do ql ZOL pue umop ql ZL L'ZL-0-6L le do ql ZOL
pue umop ql ZL L'ZL-O-LL le do ql ZO L pue umop ql ZL L'ZL-O-S l le do ql ZOl pue umop ql ZL L'Z L-O-£L le do ql ZO L pue umop ql Zl L'ZL-O-t L le do ql ZZL pue umop ql 9EL
'ZL-0-6 le do ql ZZL pue umop ql 9EL'O-0-L le do ql 179Z pue umop q!VgZ(s)peol poleilueouoo Uoddns of lua!0g;ns Pap!nad aq pet's(s)ao!nap uog09uuoo 181410 Jo(s)Ja6ueH(g
-Ssr1J1 6!14110 u6!sap pue s!s(leue ayl u!pasn sem lapow fl!xg pue jagwaw„s1aa4 bu!pnlou!sNeajgyol!d p!6u-1weS.(L
8Z lu!o.le g!1dn
ql L26 Pue 91,lu!of le u!ldn Cl 6917'61,lu!of le 1!!Idn ql£VVI.'Z lu!0!le u!ldn ql L61,6u1pue1SLQm;o algedeo eleld buueaq of ssnil;o(sja4l;d ) = auuo ueqoaW !OJd(9
S0OL 43Msagwaw yo
Aue pue pjoyo wolloq 8141 ueamlaq lg II!m ap!m 0-0-Z Lq Ilei 0-9-£916ue109i a ajaym seaJe Ile u!pioLlo wolloq ay1 uo;sd0 OZ;o peel an!I a lo;pau6!sop ueaq set'ssrul s!y.,(S
(0 L) -SMON
q Iug9e09ZWLoVSUSAu .kiOPtL`JPPXSHoOOaZa-NRZZ6U9ef^VidnNlWgNdZEV90:01 LLLZEIZAI,pj eS'Nddngsdappeueouawy
Z a6ed VLOZ VZ:9Z5t 9Z 6nV n u oul's-4snpul ma1!W VLOZ 9 6eyy s OZS'L 7uud VLOZ 9 AM s OZSL:una �� -- -
Ieuoil� ua�a;aa qor — - StEBZL
L L Jap,iE)d1H LV
1,00 ON 6mCl ad/1 Ssn� SSRI. , q.fr
ti0LZti # h, d !Jaiuem •w Lue!II!M
�64111 �Ho�s
ot
VOLWON
.
PJepuelS (S)3SVOCVO.1
'•�3SN3011 '
4LOZI8Z/80:9lea'ELOOZOOV:ub9S(8
�//�,�'•...•... � ssrul s!L41lo u6!sep pue s!s IE!ue eql u!pasn sem lapow R1!xg pue Jagwaw,shay 6u!pnlou!sleacgyol!d p!bu-!waS.(L
V09=2Z'99Z=L L'96Z=0Z
W (q1=1O ldaoxa Z(s)lu!of le u!ldn ql 00 L bu!puelsyl!m to elgedeo aleld 6uueaq of ssrul to(scalllo Aq)uogOauuoO leO!ueLloaw aP!nOJd(9
;sdo-0 L=1008 yl!m'scagLuaw Jay10 (ue pue pcoyo wolloq ayl ueemlaq
1g II!m ap!m O-O-Z Aq Ilel 0-9-£al6uelow a acaym seace Ile u!pcoyo wolloq ayl uo lsdo-OZ to peol an!I a col pau6!sap uaaq sey ssrul s!yl,(9
spe01 an!l Jalllo Aue yl!m luacJnouoouou Peol an!l pcoyo wolloq lsd 0-0 L e col pau6!sep uaaq sey ssrul s!y1(4
6u!puod J91em luanacd of ebeu!ecp alenbape ap!noJd(E
09 L=10a dub aleld 09 L=lOo Jegwnl'umoLls Suo!loew Jol SN3MW
V seocol pue scagwaw Jol 0-0'pasodxe ly6u leo!1Jan pua'pasodxa ly6u pue llal Janal!lueO'auoz O-Z-99 01 gl-B-LS(L)JOualul'SL 8 LS
of 0-0L-OL(Z)Jopelx3'O-OL-OL of ZL-L-4(L)coualul'ZL L 4 of O-4-L-(Z)Joualx3 0-0 pue(leuo!loaJ!P)S2i3Mw'8L'0=!d0J"jou3'0 dx3
'II'leo'89=9ne0'4gq=1'1;94=9'49L=y'1sdZ 4=1a08'1sdZ't7=1a01'ydwLOt=Psen(1snb puooes-£)ydw0EL=11nn'OL-L 30SV:Pu!M(Z
.u6!sap s!Lll Jol pacap!suco uaaq anei4 speol an!l looJ peouelequn(I,
(8) -S31ON
8£4/99L-=81,-9L'ZL£/4L£-=8L141'ZLS/8LZ-=8L-EL'8LL/9Zt- 6L-£L
'6Z L L/6 LE-=ZZ-Z L'£Z£/99 L L-=ZZ-6'6 L7/O=£Z-6'OOZ/SS£-=SZ-B'S Lg/L8-=sZ-L
'6L9/6L4L-=9Z-L'BLLL/004-=9Z-g'98E/89Z-=8Z-9Z'LZ9/0L9L-=8Z-9'9LE/tSt-=8Z-4 S93M
£6£/4ZZ L-=OZ-Z L'964/8L-=0Z-6 L'LL L/6SZ=ZZ-L L'L 9E L/LSE-=£Z-ZZ
'L89L/E8E-=4Z-£Z'L89N/CK-9Z17Z'991,L/OZZ- 9Z-9Z'ZOZ/LZ£=9Z-9'80Z/E8E-=8Z-Z OaOHO109
84£/899-=LL-S4'EL£469-=L4-gL'£L£/LZ9-1Lt 04
'£ZE/6Lt-Ot-4L'Z84/4£9-=4L-EL'OZ£/091,-=£L-ZL'9£4/ZZS-=ZL-LL'8E4/S£S-=LL-0L
'8E4/9£9-=6£-0 L'8£4/9£9=6£-6'Z89/684 L-=8£-6'Z89/684 L-=8£-L£'Z89/684 L-=L£-8
'869/89£L-=9-L'8L9/86L =S 4'084/SS=4£4'LS4/E9=4£££'044/49-=££-£'0/499-=£-2 OaOHO d01
,umoys uaym ldaoxa ssal Jo(ql)OSZ saocol IIV- u91 xew/dwo0-xew-(ql) 'S33HOd
(LZ 01)£EOZ=8Z'(8L 01)069=LL'(ZZ 01)ZSLL=OZ ldaoxa Z(s)lu!of le ssel Jo ql OgZ suopoeaJ pV neJO xew
(ZL 01)409- 8Z'(ZL 01)99Z-=LL'(ZL 01)96Z-=0Z ldaoxa Z(s)lu!of le ssal Jo ql OOL 4!ldn IIV 4!Idn xew
(LL01)LSZ=Z-OH xew -(ql)
'4-9-0=LL'0-4-0=Z(yl6ual=lf)ldaoxa 0-9-0 sbuueaq IIV 'SNOLLOV3a
ap!n uopepelsul
Jaz!l!gelS y1!m eouepc000e u!'uogoeia ssrul 6uunp pa!lelsu!eq
0-9-1 E'oN dS 4x211(31 2i3011S
6woecq ssoJO paJ!nbaJ pue scaz!l!gelg leyl spuawwooaJ>la1!w
L —--- --- --- £*ON dS 4xZ S93M
6L-£L'ZZ-6'9Z-L ldp!w le moa L S93M E'ON dS 4xZ:98'49'Z9
6u!oecq oo 0-0-9 Jo pa!ldde Alloanp 6u!I!eo p!6!a (IHOHO 109 ,ldaoxa.Z'ON dS 4xZ (180HO 109
sleO!yan pua Z'ON dS 4xZ:£1'L1
ldaoxa 'su!lJnd oo 4L-4-9 Jo pe!ldde lloaJ!p bu!4leegs poom lecnlonJlS GHOHO d01 ,ldaoxa.Z'ON dS 9xZ GUGHO d01
-ONIOVUS -213ewm
%OZ=13 ql 89£ 1y6!9M (w-x!Jlew) LOOZIdl/OLOZ083 WOO 0-OL 1(309
e/u e/u OZ 0V (ll)-OH L6'0 9M S3A Joul ssaJlS daa 0'0 1108
08L 69Z< LE-8Z44'0- (ll)lJan 46'0 08 gZ'L eseaJoulcagwnl 0'OL 1a01
06L/44Z OZ-Lw 04Z 846< 6L-8L LVO- 01)1,(3^ 69'0 01 SZ'L aseOJOul saleld 0'OZ 1101
drdD S31V'ld Pn u9p/I (oo!) u! '133(3 'ISO O-O-Z -ONIOWS (lsd)ONI(3VO-1
- e 3 0-Z-0:9Z 'a P3'ZL-Z-O:ZZ O-Z-O'SL-Z-O:SL -Z-O'O-£-0:£t '9-4-0'0-£-0:9 Z-O'O-£-0:9 ' L-L-O'£L-Z-O:Z 'xSlesgo eleld
o-to
sus stns ole o-rz , o-ee oee oe9 Lcz o-tts
tB vs sLo er o-o-w 0-mor 0-9-WE o-ot ez L-z-Lz Lo zt o-Lts
O-WM
II 4x£ =9x£ —9x4 =9xL
LL 9L E6 Z4 % —9x4 =9x£ =9xL =9x£ 9x4
! 4x£ =9x£ =9x£ vx£
N
�¢ � Lz £z vz sz cz 9z
zz
m
91,st L
z L10
gxy 9 £
L4 Oq 4E 9x£
YL M OL SM 4
4xZ 4xZ
£L ZL LL OL 6£ 9E L£9 9£L 5£ 9 S zo 00.9
9x19 =9xS II 17x£ —qxy =9xL —4x4 4x£ =9x9
=9x0
ul 4/1,='Ua0 PeOl PeaO
.L=.B/L:aleoS
zL-rL o-L-£ o-gz o-s�s o�s-s o-s9 L-9-L sLs p-ra,
o-z2 sL o tb o-o-w AN" 0-9-9£ o-o-ze o—z L=o-si C o-z, o-oL oL LLQ s A-rLl
z IfA1J6Sooldr3Rl0a`JAzP3 Z XuOJ i3£!rlawwi0e-NR�6�IA8erm LdnNtwq�ldz£V90:a1
L�d YLOz 9z:8z:4L 9Z Oni/nVl'-I'-!jisnpul)Ia1W 4LOZ 8 eW S OZS'L auPd 4LOZ 9 eW s OZS'L:unu LLLZE ld'px4ueS'NddnS slappe ueouawy
leual o aouacalea qor
L L dIH OLV 9L£9ZL
E00 ON rYA0 f4d
BdIL .1 9SfU OY
bOLZV # d `!aa!uem -W Lue111!M
61H o
y .�
:10 31d1s
VOLZV OON
Z
3 . 3SN301� .
•�. �, � �+ PJePue1S (S)3SV0 OVOI
1r/d.'�.•,.... �
�/(j7/ ■'u 4lOZ/8Z/80:alea'SLOOZ00`d:ub9S(8
r' -ssrul s!4110 u6!sop pue s!s(leue a41 u!pasn sem lepow ti!xy pue jagwaw„slaaq bu!pnlou!s�e9jg4o1!d p!6u-!waS,.(L
'Z94=6Z'LE£=L L
(gl=1D ldaoxa 91'Z(s)lu!of le g!ldn ql OOL bu!puels4l!m10 elgedeo aleld 6uueaq of ssrul to(sJa410 (q)uo!loauuoo leo!uegoew ap!noJd(9
1sd0 O L=1408 41!m'sJ9gwaw Ja4lo Aue pue pJo4o wolloq 441 uaamlaq
lr1 Illm opm 0-0-Z Aq Ilel 0-9-E ol6ueloaJ a 9Ja4m seeie Ile u!pJo4o wolloq a41 uo 1sd0 OZ 10 Peol an!l a Jol pou6!sep uaaq se4 ssrul s!41,(S
speol an!l JB410 Rue 4l!m luaunouoouou peol an!l pJo4o wolloq;sd 0 01,a Jot pau61sep uaaq se4 ssrul s!41(4
6u!puod Jalem luanaJd of 96eu!eJp 9lenbape eP!nad(E
09'L=104
dub 9leld 09-L=100 Jagwnl'umo4s suopoe9J Jot S83MW g sago;pue sJ9gwaw Jot 0-3'pasodxa 146u pue 1191 Jan9lpue0'9u0z E-6-94
010-01,1,1,(Z)JO!J91x3'0-01,-41,01 Z-£-E(L)JO!Jalul'Z-£-E of 0 4 L (Z)Jou9lx3 0-0 pue(leuopoeup)Sa3MW'8L'0=!dOJ'.10u3:O dx3
'II'leo'll9=anea'3194=1'l1s4=8'31S L=4'1sdZ'4=1408'1sdZ'4=1001'4dw LO L=Psen(lsn6 pu000s-E)4dw0E L=11nn'0 L-L 30SV:Pu!M(Z
-u6!sop s!41 Jot paJap!suo0 uaaq ane4 speol an!I 104 peouelequn(l,
(8) -S31ON
549/48 L-=L Z-0 L'SL9/LLL-=L Z-8 L
81,£/9£LL=LI LL'L8ll/99£=81, 1,1,'01,£/£98=81, 0L'88L/89E-=LZ-8'L4E/0=EZ-L
'88Z/Z1,6-=SZ-L'6ZOL/80E-=SZ-9'089/89EL-=LZ-9'489/£9£1,-=6Z-LZ'86L/LLE-=6Z-4 S83M
9£Z/88Z-=L L-Z L'179 L L/OLZ-=ZZ-1,Z
'89ZL/44£-=04-ZZ'89ZL/44£-=04-EZ'99ZL/44E-=6£-£Z'89ZL/44E-=6E-4Z'29ZL/44£-=9Z-4Z aaOH010e
88E/S48-=L 1,-0 L'909/£9Z 1,-=8£-0 L'909/E9Z 1,-=8£-6'909/E9Z L-=LE-6
'909/£9Z1,-=LE-8'ZOS/69Z1,-=9-L'80£/L49-=9E-L'80£/L49-=9E-9'66Z/L9L-=9-9'0/8£L-=E-Z Oa01-13dOl
umo4s ua4m ldaoxa ssel Jo(ql)OSZ saoJol IIV--ua1-xeW/-dwo0 xeln!-(ql) -S30a03
(LL 01)96LL=6Z'(8L 01)1,851,=LL'(L Ol)E8£=Z ldaoxa SL(s)lu!oL1e ss91Jo ql OSZ suogOeaJ IIV neJO xeW
(Z1,01)Z94-=6Z'(Z1,01)L£E-=L L ldaoxa S L'Z(s)lu!of le ssel jo ql 00 L 8!ldn IIV u!ldn xeW
(Z1,31)L6I,=2-014 xepy -(ql)
4-L-0=9 L'0 4 0=Z(416u91=1n ldaoxa 0-9-0 s6uueeq IIV 'SNOLLOV3a
-apino uogepelsul
jaz!I!ge1S 41!m eouepJ000e u!'uogoeje ssrul 6uunp pallelsu!eq
6u!oeJq ssoJo paJ!nboi pue sJazll!gelS 1e41 spuewwooei�a1!yy 0-9-1,£'ON dS 4xZ Sal a3aI1S
'8L-M U-L'SZ-L ldp!w le moa L SE13M £'ON dS 4xZ S83M
-6u!oeJq oo 0-0-9 jo pe!ldde AIloaJ!p 6u!I!ao p!6!a OaOHO 109 E'ON dS 4xZ:98'48'Z8
s1e0!1Jan pua ,ldaoxa.Z*ON dS 4xZ M101-13 10e
ldaoxa 'su!und oo L-OL-4 Jo pe!Idde Rpoeu p bu!41eags poom leinloMS (180HO d01 Z-ON dS 4xZ Oa01-10 d01
-E)NIOVa9 -a38Wnl
%OZ-13 gll££'34619M (W-x!11eW) L00ZId1/0L0Z08391303 0-01, 1408
e/u e/u LI, SO'0 (11)-OH 4L 0 9M S3.1 Joul ssaJ1S daa O'0 1109
081, £9Z< ZE-6Z 54 0- (11)1JaA 99'0 09 SZ'L aseaJoul J9gwnl 0'01, 1001
06V"Z OZ1W 04Z L89< ZE-6Z LL'0- (11)1Jan Z9'0 01 SZ'L aseaJoul saleld 0'0Z 1101
drdS S31Vld p/1 IIaP/I (001) u! 1330 ISO 0-0-Z -0NIOVdS (1sd)SNICIVOl
_ - 8Z0'8ZO1,Z '0-Z�'0£OL1, '0Z-0'0£09 '0£�'0£0'S ' L-L-O£IZOZ X518s110a1e1d
LI9-4-0 Z-0-9 0-k-0 0-0-1, 0 Z 9 0 8 Z £8S 4LS 9 SL£Z O L Z O-LL-6
-st, Z-LLS4 0-1, S4 0-01,-04 OVI 08LZ L-OSZ 4L-E-LZ OOL41, L9-ZL 0-LL-6
11 4xE =9x4
SL 91, _ PC 11
Wt _9x5 =8x4 II 4xZ II 4x£ -01,x£ 4xE 9x4
=4xZ
NI N
�i gl 1,4 81, 61, 114xEoz 04 6£ VZ 114xE8Z
4 6Z o
1 111 Z
_ 20A E
4 4E i 9xE
b SL 4 81, ZIA
Elk
SIN4
6M LM SE 4xZ
EL S
9x4
i 9x9
ZL 1,1, BE OL 6 LE B L 9E 9
=9x9 =9x£ =9xE 11 w =Bx£
II 4xE =9xs ZL 00'9
u!4/1,=1180 peal pe80
938:1,L=81e0S
8OS
0-M LLQ 0Z9 0Z9 08Z E8£ 4LSiJ SLSZ FILA
SL04 LLS 4
L-LLS4 GTI, 4 0-0-04 OGLE£ 0 8 LZ L 0 SZ 41,5 LZ OCL 41, 1,$ZL 0 LL 6 L OLS 4 1,
X I(�WluLMnAXHh'.1P1,!(L09mx4/WLJgAN6ELndX-Nffzzweefmc)dnNiWgN OI
L ibBd 4LOZ BZ:BZ:SL 9Z Bnv ny1-1'Seulsnpul HaLW KOZ 8 ABW S 0Z9-L:luud 4LOZ 6 BW S 0Z9-L:una LLLZ£lj'P+WuBS'IGddng slagmB uxwaury
leual o aOueJalaa g0f
L L d!H Kv S5f1J �
SL£BZL
500 ON 6ma .
edA Ssnl
ti01Zti # d `P011uea •w Lue1II!M
�r�•:10 31vis
PJepuelS (S)3SVO OVOI
's VOLWON =
4LOZ/8Z/80:e3eO'LLOOZOOV:ubaS(6
-] . 3S N3�1� � ssru;s!4;to u6!sap pue s!s(leue ay;u!pasn seen lapow fl!xg pue JagwoN ,shay bu!pnlou!s>eaJgLlo1!d p!6u-!w9S„(8
'o .� � � SL lwof 1e g!ldn ql OZZ Pue 6L lu!of le 4!ldn ql£LZ
�fj�,,''.•���...•'•, ` '9Z;u!of;e u!ldn cil 04£'Z lu!of;e u!!dn ql OZ L bu!pue;sy;!mjo algedeo a;eld 6uueaq o;ssru;;o(sjeglo Rq)uo!;oauuoo leO!ueyoaw aP!nad(L
J�1V/ ■� `��\ !� -suogoauuoo ssru;o;ssru;jo;(s)japc!b o;ja;aa(g
r` ;sdO O l=1409 qlM'sjagwaw ia410(ue pue pjoyo wo;;oq ay;uaann;aq
lg ll!M ep!m O-O-Z Aq llel 0-9-£a!6ueloaJ a aJa4m sewe lieu!pJoyo wopoq 0,43 uo;sd0 OZ bo peol OA!l a Jol pau6!SaP uaaq se4 ssrul s!yl.(S
Speol aA!1 J9y10/pue L11!m;uaunouoouou peo!0,A!l pJogo wolloq;sd 0-OL a Jo;pau6!sep uaaq se4 ssrul s!y1(4
6u!puod J81em luaneJd o;o6eweJp a;enbape ap!AOJd(£
09'L=100 dub a;e!d Og L=1O0 Jagwnl:unno4s suopoeaJ Jol Sa3MW
g sacuo;pue sJagwew Jo;O-0:pasodxe 1y6u Pue 401 Jana!pueo:auoz 61-04 01 0-0-9£(Z)Joualx3'0-0-9£01 ZL-6-LZ(L)Joualui'OL-O-£Z
0;8-£-8 L(Z)Joualx3'8£8l 01 4L-L-£(L)Joualul'4L-L-E 0;0-4-L-(Z)Jopelx3 0-0 pue(leuo!loaJ!P)SadMW'8 L'O=!d00'!ou3'O dx3
II le0'3;5=anea a1S4=1'854=8'31SL=4'1sdZ'4=1408'lsdZ'4=1001'4dwLOL=Psen(;sn6 puooes-£)4dwOEL=jlnA'0L-L 30SV Pu!M(Z
'u6!Sap S!41 Jo)PaJ8p!su00 uaaq ane4 Sp801 aA!l;oa peouelequn(l,
(6) -S31ON
45L/ZOS-=LZ-6'48Z/6LL-=9Z-L'9L£/599-=SL-£L'L84/S4=9L LL
'Z0L/£9£-=9L-LL'89L/08£-=LZ-0L'48Z/99L-=LZ-6L'L8£/L98-=8Z-9Z'46L/£LE-=8Z-4 S93M
L4£/99L-=S4-S L'L4E/95 L-=94-44
'L4£/9S L-=44-9 L'S4E/49-=L 4-L Z'94£/49-=L 4-ZZ'L04/6L L-=04-ZZ'L04/6L L-=04-£Z
'Z04/06L-=6£-EZ'Z04/O6L-=6E-4Z'Z04/06L-=SZ-4Z'S84/L4L-=9Z-SZ'SL£/68L-=8Z-Z (180HO109
EZ£/LLS-=£L-Z L'8E£/0£4-=8£-Z L
S£'8££/0£4-=9£-1,1,'9L£/L8Z-=L L-01,
'66Z/9LZ-=OL-6'E4£/SS4-=6-8'04£/695-=8-L'LLL/S££-=£6-4'00[/ZSE-=££-£'0/LLL-=E-Z GHOHOdOl
,umoLys u94m ldaoxa ssal Jo(q!)OgZ sacuo;IIV-,u91 xeVq/dwo0-xeh-(ql) 'S33NOd
(8 L
Ol)OL8=SL'LL L 01)M4=6 1,'(L L 01)9££1,=9Z'(L 01)Z84=Z ldaoxa(s)lu!of le ssal Jo q!09Z suogoew 11V AeJC)xeln!
(Z1,
01)OZZ-91,'(Z1,0-1)ELZ-=61,'(Z1,0l)04E-=8Z'(ZL Ol)OZL-=Z ldaoxa(s)lu!0f le ssal j0 ql 001,8!idn IIV U!idn xeW
(Z1,01)4LZ=Z-0Hxew -(ql)
!eo!ueyoaw=S L'p 4 p=Z(4;6ua1=1f)ldaoxa 0-9-0 s6uueaq IIV 'SNOLLOVEIN
ul
uijn oli e!u!0,q
Jaz!I!ge;S y1!m aouepJ000e u!'uo!1oaJa ssru;6uunp papelsu!0,q
bu!oeJq sscuo paJ!nbai pue sJ9zp!ge1S 1e41 spuewwooei Jlal!yi 0-9-1,E'ON dS 4xZ 01 H30I1S
LZfi'SL£L'91,-ZL'9L-LL'61,-01.'£Z-8 ldpluJlemoal S93M £-ONdS4xZ S93M
6u!oeJq oo 0-0-9 Jo pe!ldde(llocuip 6u!1!eo pft! j GHOHO 109 £'ON dS 4xZ:49'Z9
sle3!1J9A PUB ,IdaoxA.Z'ON dS 4xZ GH01,10 109
ldaoxa 'su!und oo E-£-£Jo pe!!dde Alloei p bu!41eaLis pooh IeJnlorujS 42101-13 d01 Z'ON dS 4xZ GHOHO d01
-QJNIOVIIS -N39Wn-i
%OZ=ld cil 4Z£:146ieM (yy-XL4eW) L00Zldl/0L0Z09d aP00 001, 1409
e/u e/u SL 60'0 (11)-01-11 88'0 9M S31. Joul ssaJ1S daH 0'0 1108
09L £Z4< LE-8Z8Z'0- (ll)1JOA 98'0 09 SZ'L aseaJou!Jagwnl 0-01 1001
06L/44Z OZ1W OhZ LSS< 91,-51,4Z 0- (11)IJOA £8'0 Ol SZ'L aseaJou!saleld 0'0Z 1101
dIH9 S31V3d P/l gap/I (001) u! '1430 'ISO 0-0-Z -`JNIOVdS (lsd)ONIOVO-1
_- - 0Z00E0'ZL '8Z0'O�JO'lL '0Z0'0E08 'e P3'L-4OZ 'X s1Gg408leld
e-s-o
EL-o- ZL-L-L L -0O-L-Z 8.9-9 LSS O-L-Z 0-11
e1,-0Lrr 0-0-9e o-cLz L-0sz 9E9L L�zL o-LL�
ZV6-LZ
W9
4xZ =9xE
II 4xZ II vn 4xZ 11
4x4 —Sin =9x£ 11 w 114xZ =4xE 8xE
9L 54 vv 91, E4 Ll, 91,6l 1,4 OZ 04 6£ vz LZ 11 9xBZ
cz
CAI oI s zZON 1,
EE £
4x£
co Sl 61, 9
0 NA
Q SIR
ZH 4 M 1, S 4xz
o Z g
41,
46 9xc
II 4xZ
11 YxZ
EL L
yxE to
ZL B£ LE gE S£ LL OL 6 e ZL 00'9
=4xE
=9x9 =9x9 =gxg
u!4/1,='110,0 Peol PeaO =9x9
L'99 L=91e0S
E-L-V LL-E-V ZL-L-L 9W6-Z L-LL-L, Z-6i 9-1,-6 Z-9-L 0-1-ZSL-0-► L-0LS 0-4-1,
EL-01,-44 LLi.`04 049E
t, -LZ L-0-9Z OL-0Ez 9-c-9L Z-Z-4L L9zl 0-LL� L-0LS L
A Iu3dnEZxdA69£dAnnLduB£daISLldN1LONN11091-NRZLz6J1A8efmJ`LdnNlWq�dzEV8o:01
L a6ed YLOz OE:9z:SL 9z 6ntl nLLL'aul'ss.mnpul HalW 4LOZ B eW s OZS'L.1uud 4L0Z 8 eW s OZS'L:una LLLZ£-u'pplue8'Nddng slap a uew u v
!eu o eouejejeU qof
t L leoedS h2f 9Ltl SLE9ZL
LOO ON BMG
AId Alp adR ssruI ssnJ 0
tiOLZti # 31 d 6!a8111Aeb •w LUCII !M
Ho
31d1S
's ti0LZV 40N =
kiw
'
(8)645=6(8)t69=8(8)£09ol Uan
(ql)speol paleiluaouoO
OZ-9-17'09—C-1,:1JBA
old)speol-oi!uN
SZ-L=aseaJoul aleld'SZ'L=aseajoul jagwnl:(peoueleq)aA!1 i0oa+PeaO(i,
PJepuelS (S)3SVO OVOI
41,0Z/8Z/80 a1eO'6LOOZOOyubaS(L L
jagwnl 41!m loelu00 u!s!Jabueq aja4m selo4 I!eu Ile II!3(0 L
-pjo4o wolloq jo aoei Moeq of(dS 4xZ Aid L)9 LV'(dS 4xZ{id L)91,V'(dS 4xZ (id L)OZV(sa)ssrul loauu03 01 4-01-4 0l pue 4al a4l wai
4-OL-0le bu!liels-xew o0 0-0-Z le peoeds lualeA!nbe Jo(JaPJ!O Aid elbu!S'ssrul POL-4'JePJ!o POL-4L)9ZSf1H 8!1-6u0AS uosdw!s asn(6
ssrul s!4l jo u6!sap pue s!sAleue a4l u!pesn sem!apow Rl!xg pua jagwan„shay 6u!pn!ou!sNe9jg4ol!d p!6u-!was.(8
'4
lu!of le g!ldn ql 50£pue 9 lu!of le u!idn q!9££bu!puels4l!m jo algedeo aleld 6wjeeq of ssrul jo(sja4lo Rq)uogoauuoo le3!ue4oaw ap!AoJd(L
siagwaw ja410 Aue pue pio40 wolloq a4l uaangaq
19 Mm aP!m 0-0-Z (q lie)0-9-£al6ueloaj a aaa4m sewe lie u!pio4o wolloq a4l uo isd0-0Z io Peol aA!I a jol pau6!sap uaaq se4 ssrul s!41,(9
speol aA!l J84lo Cue 4l!m luaunouoouou peol 9A!l pjo4o wolloq isd 0 0 L e poi peu6!sap uaaq se4 ssrul s!41(5
6u!puod jalem luanajd of abeu!ejp alenbape aP!AOJd(4
09'L=100 dub aleld 09'L=100 Jagwnl'pasodxe 146u pue 491 Janal!lueo'(leuo!loaJ!P)SHjMW'8L-0=!d0O'Pu3'0 dx3
Ill leO'1;4=anea'4VZ=1'1154=8'1151,=4'lsdZ 4=1OO8'lsdZ'4=14O1'4dwt0L=Psen(lsn6 puooes-£)4dwoCL=1Inn'0L-L 3OSV:Pu!M(£
paleo!pu!aswua4lo ssalun'(g)jo(d)se palou speol Aluo aynquls!p of pap!Aad uaaq ane4 suogoauuoo
Aid 01 Aid-uo!l00s(S)3SVO OVO-1 441 u!aoei(g)moeq jo(3)lual se pelou i!ldaoxa'sa!ld lie of pa!ldde Al!enbe paapsuoo aje speol IIV(Z
00 0-6-0 le mOJ t-4xZ:smol!03 se paloauuoo sg9M
'00 0-6-0 le paA66els smog Z-9xZ:smo!!oi se paloauuoo SPJo4o wollog
00 0-6-0 le ma L-4xZ:smoiloi se paloauuoo spio4o dol
:smol!ol se sl!eu(.£x.t£1,'0)POL 411m j94la6ol paloauuoo aq of ssrul Aid-Z(L
(t L) -S31ON
LOOZ/665-=5-£'LOOZ/665-=5-1, S83M
6 LZ/989-=4-£'ELS/OZ6 L-=£-Z'£LS/OZ6 L-=Z-L'6 LZ/989-=9-1, ONOHO dO1
umo4s ua4m ldaoxa ssel io(ql)OSZ seojoi llV--ual-xeyy/dwoO,xepy-(ql) -S30NO3
(4 01)90£-=4'(4 01)9££-=98!ldn xeIN
(8-1,-0-u!w) 0-4-0/586=4'(8-1-0'u!w) 0-9-01Z9Z1,=9 (ez!s/ql) 'SNOILOV3N
6u!oejq 00 0-0-OL Jo pe!!dde Rp0ai!p 6u!pao p!&H GHOHO 108 £ON dS 4xZ S83M
s!e0!y9A Pua Z'ON dS 9xZ GHOHO 108
ldaoxa 'su!pnd 00 0-0-9 jo pa!ldde Apai!p 6u!4lea4s poom leinlorulS GHOHO dO1 Z'ON dS 4xZ GHOHO dO1
-9NIOVNS -k13awn-i
%OZ=13 ql£L:I4619M (W-x!jleW) L00ZId1101,0ZO8d 8PO0 0'01, 1408
e/u e/u 4 00'0 (ll)-OH 8£'0 8M ON Joul ss9j1S d98 0'0 1108
08L 666< 5 90'0- (11)7Pan £Z0 08 SZ-L aseajouljagwnl 0'01, 1001
061,/44Z OZ1W 04Z 666< 5 Z00- (T*Jan Z1,0 01 9z,1, aseajoulSaleld 0'0Z 1101
dRIS S31V1d P(1 u9p/I (ool) u! '1330 'ISO 0-0-Z -'JNIOVdS (lsd)VNIOVOI
O-L-9 9-B-£
I 14x2
14x2 y 9
9ZSf1H =9x4 9ZSf1H 9ZSnH
6 S 9 L
1,8
ZA3 cmLM 1,A3
L
£ Z L
=4x4 11 4x2 =4x4
ZZ V L=aie3S
0 L-9 "-C
1 IKLnLAWdA98133f ndObslSOl43f' LP4l1NXnPLed-NR.z6)IA8efmJLdnMVyq)jdz£V8o:Oi
L abed 4LOZ Z£:BZ:SL 8Z mV nuj_:u!'sauysnpui Ha11W 4LOZ B eW s OZS'L:luPd YLOZ 8 eW S OZS'L:una LLLZ6 lj'Lua4ueS'AW4nS sfappg ueouawy
leuo!y o eouejejea qor
Z L JaW!E)lelj DANSLEBZL
600 WJ 6m0 ' .
Nd ad(1 ssru-L ssrul qof
VOLZti # 0 d POW011 .w Lue!11!M
Q 31115
Pits VOLZVON =
3SN30I1�
EW
(d)Z£LL-=9Z U9139-=9Z UZ69-=117Z(J)98S-=£Z(J)9139-=ZZ(J)13£ZZ-=OZ 1Jan
(ql)speo-I palellueouoO
OZ-91,171.'OZ-=Z L-9'OZ-=9 L-Z L'09-=L-9'09-=9-E'09—C-1,:1Jan
Old)speol-ol!un
00'L=aseaJoul aleld'00'L=aseaioul jagwn-1:(paoueleq)an!-1 loon+PeaO(l,
PJepuelS (S)3SVO O`dOI
VLOZ/13Z/130 ale0'OZOOZOOV ubaS(S L
jagwnl 41!m loeluoo u!s!ja6ue4 9ja4m s91014 1!eu lie Il!d(YL
PJo40
wolloq 10 aoel luO4 01(dS 9xZ Lid Z) LJd(se)ssrul loauuoo 01 Pua 11011341 wo.46-£-LL le lualen!nba jo(ssrul p0L-q'japnO POL-ZZ)Z-13ZSf1HH a!1-bualS uosdw!S ash(£L
pio4o wolloq to aoel luo4 01(dS 9xZ Lld L)EV8'(dS 9xZ Aid L)ZVO'(dS 9xZ Aid L) LVO'(dS 9xZ Aid L)VO(sa)ssrul
loauuoo 01 q-£-9 L 01 Pua 31al 1341 W04 4-£-O L le 6upels-xew oo 0-0-Z le pooeds lualen!nbe jo(JaPJ!O Aid 916u!S'ssrul p0 L-4'JaPJ!O POL-ZZ)13ZSf1H a!1-6uoj1S uosdw!S asn(ZL
(9L) -S310N
b Iu1JSL6sJV LW69LeHdAL9aSE0o0J148(dDrOdzl-NRZz6�A8efmOidnNlWQNdzEV90:01
Z eAed YLOZ K:gz:9L BZ 6nV ntu oul'saulsnpul�IaliW 4LOZ 9 eW s OZ9-L:luud 4LOZ 8 AeW S OZS L:una LLLZE l3'pJWueS'Nddns sdappg ueouau v
leual o aomalaa g0f —�--
Z L 3SVg NOVR),991d `JV �. M�O-
3CM19WO ON 6+"URld /Gb ad�(1 ssrul ssrul
VOLzt, # 3 d °!aa!uea •w Lue!II!M
VOLWON o
,3SN30Il .A
■r' ■■�� piepuelS (S)3S`dO OVOI
410Z/8Z/80:91e0'LZOOZOOV:ubaS(6
ssnil s!yl;o u6!sap pue s!s(leue a41 u!pasn sem lapow p!xg pua jagwaw„shay bu!pnpu!sHeajggol!d p!6u-!weS„(9
11 lu!of le 4!ldn ql 4£Z pue
Z lu!of le 4!ldn ql 81'L lu!of le u!ldn ql LZ t 6u!puels4l!m;o algedeo aleld 6uueaq of ssrul jo(sj94lo (q)uo!loeuuoo leo!ueyoaw ap!nad(L
-suo!loeuuoo ssrul of ssrul jo;(s)japj!6 of ja;aa(9
;sd0'0 L=1008 4l!m'sjagwew jaylo Aue pue pio4o wolloq aril uaamlaq
14 ll!m eP!m 0-0-Z Lq Ilel 0-9-£916ueloai a aja4m seaie Ile u!pioyo wolloq a41 uo;sd0 OZ;o peol an!I a jol pou6!sap uaaq se4 ssrul s!y1.(9
Speol an!l Jaylo Rue Lll!m lueunouoouou Peol an!I PJoyo wolloq;sd 0.01 a jo;pa4sep uaaq se4 ssrul s!41(q
bu!puod JaleM luanajd of 96eupp alenbape ap!nad(£
09'1=100
dub aleld 09-1=100 Jagwnl:umoys suopoew jo;Sa3Mw g soojo;pue sjagwew jo;0-0:posodxe ly6u pue>}al Janaylueo:auoz
8-£-91 01 8-£-ZL(Z)J0ualx3'8-£-Z1 010-9-1.(1)Jou9lul'0-8-1 of 0-4-1-(Z)Joualx3 0-0 pue(leuopoeip)Sa3Mw'81'0=!d00'lou3'0 dx3
II'le0'3}4=anea:l;qZ=1'3;94=8'7491=4';sdZ 4=1008';sdZ'4=1001'4dw LOL=PseA(lsn6 puooes-£)4dw0£L=llnn'01,-L 30SV:Pu!M(Z
u6!sap s!Ill jo;pajap!suoo uaaq aney Speol an!I;oa peouelequn(L
(6) -S31ON
441/6L£-=L5 S83M
£0£/919-=01,14 OaOH0109
0l/88Z-=L1-4'89L/ZL£-=E-Z OaOHO d01
umoys ua4m ldaoxa ssal Jo(ql)09Z seojo;IIV--ual-xew/-dwo0-xeyy-(ql) -S30a03
(L1 01)969=11'(1 01)60£=Z'(L1 01)684=LnWO xew
(Z 1,01)4£Z-=L l'(Z1 01)8[-=Z'Q1,Ol)LZ1-=L34!Idn xew
(Z1,Ol)49Z=Z-OH xew
(8-1,-O'u!w) 8-8-0/L99=1,1'(8-1-0 u!w) 0-4-0/60£=Z'IeO!uey3aw/694=L (ez!s/ql) 'SNOLLOV3a
"epinb uo!lepelsul
jaz!I!gelS rll!m eouepj000e u!'uo!loeja ssn4 6uunp pallelsu!aq
6u!oejq ssao pajrnbei pue sjaz!I!gelS 1e41 spuawwooaj�al!w 0-9-1£'oN dS 4xZ Sal a3011S
Z--9'Z-9 ldp!w le moa L S83M £'oN dS 4xZ S83M
6u!oejq o0 0 0-01 jo pa!Idde Rpoanp 6u!I!ao p!6!a OaOHO 108 £'oN dS 4xZ:ZB
sleo!uan PUG ,ldaoxa.Z'oN dS 4xZ GHOHO 108
ldaoxa 'su!und oo 0-0-9 jo pa!ldde Alloanp 6u!4leegs poom IeinlorulS OaOHO d01 Z'oN dS 4xZ OHOHO d01
°JNIOVaB -k13awn-i
%OZ=13 ql 911:146iaM (w-xulew) L00ZIdl/010Z083 ePoO 0'01 1008
e/u e/u L £0'0 (ll)zJOH 81,'0 8M S3A Joul ssailS daa 0'0 1108
09L 666< 6-8 11'0- (ll)IJan i £9'0 08 9Z 1 aseajoul jegwnl 0'01 1001
06I./W OZlw O4Z 666< 6-8 40'0- (ll)IJen £4'0 01 9Z 1 aseaaoul saleld 0'0Z 1101
dPJD S31VId P/1 UaP/I (001) u! 'Id30 'ISO 0-0-Z -QJNIOVdS (;sd)'JNIOVOI
----- 0-Z-0'45-0:9 '6-1-O'L-E-0:Z 'X slasy0 eleld
0 -V 6-4-9 1L�Lp VAS
oTl L 8-£-ZL L OL V-0-9
qxg =4x£ I I VXZ
L 8 6
EH
ro 11 9x£
1 =9x4
LZ
Le
L�
Z
9l £
ZAN IA
4x£
V
VX£
LL Z1 00'9
9OZ 61111 g
£'09:L=aleDs I I V.Z =Bx4
Q LL-V 1 6-4-9 SL OLS 0-YL
9ZL1, BEZL 91,- Lo - 0141.
0 ICAS171w)IS L-JIeMvbSflwlwOE)z 1 i46x-IOAXwd6b-NRzz6)L sereno`LdnNMw N&CVBoAI
L e6ed 9LOZ g£:BZ:%8Z Env n41'oul'sautsnpul HaLW 4LOZ 8 Xew S OZg'L auud 4LOZ B eyy s OZ9'L:una LLLZ£ld'R*jues'Nddng s�apl!ne u-pawy
leual o eoua�a;aa qop
L L 4�l!douaW to SL£BZL
L LO ON&0
N.Y Attt 9M ssrul ssrul qof
170M? # d `iaaiuem •W Luelipm
••`dia010%1
do 31vis 't
VOLZV'ON =
•
��'•3SN301-1 .•' �
V '
M •,
pJepuelS (S)3SVO OVOI
4LOZ/8Z/80 a1e0'£ZOOZOOV ubaS(6
ssrul s!41 to ub!sap pue s!s(leue atl u!pasn sem lapow 4!xg pue j9gw9A„shat bu!pnlou!sMeajg4ol!d p!6u-!waS„(8
ZL 1U!Of le 4!ldn ql 96L Pue
Z lu!of le g!Idn ql L9 18 lu!of le 4!ldn ql Z£L 6u!puelstl!m to algedeo aleld 6uueeq of ssrul to(siatlo (q)uop euuo0 le0!uet0aw ap!nad(L
-suogoauuoo ssrul of ssrul jol(s)japn6 of jalad(9
lsd0'0 L=1009 4l!m'sjagwew ja4lo (ue pue pimp wolloq atl uaamleq
Ig 11!m aP!m 0-0-Z Jfq Ile1 0-9-£al6ueloaj a ajagm seaie Ile u!pimp wolloq e41 uo lsd0-0Z to peol anp a sol paub!sap uaaq set ssrul s!tl,(5
Speol an!l iatlo (ue 4pm luaLnouoouou Peol an!l pjoto wolloq lsd(yo L e jol pau6!sap uaaq set ssnil s!41(4
'bu!puod Salem luanajd of obeu!ejp alenbape ap!nad(£
09'L=100
dub aleld 09'L=100 Jagwnl'umo4s suogoew jol S2I IMIN g sawol pue sjagwaw jol 0-0'pasodxa lt6u Pue Sal Janalgueo'auoz
8-£-L L 01 8-£-8(Z)Jouaix3'8-£-8 01 0-8-L(L)JOuaiul'0-8-1,01 0-4-1,-(Z)Joualx3 0-0 pue(leuo!loaip)S213MW'8 L'0=!d0J'10u3'0 dx3
'II'le0'44=anea')44Z=1'4917=9'4S L=4'isdZ'4=1009'lsdZ'4=1001'4dw LO L=Psen(lsnb puooes-£)4dw0£L=11nA'0 L-L 30SV:Pu!M(Z
u6!sap s!41 J01 paiap!su00 uaaq ane4 speol an!l loa paoue!equn(L
(6) -S31ON
69L/99£-=8-9'OLZ/0=6-S'L9/L6£-=OL-S S93M
L61,/89Z-=LL-4'1,Z£/£L-=1,1,-01, GHOHOl09
umots ua4m ldaoxa ssel io(ql)O9Z seojol llV-'ual xeW/dwo0-xeVy-(ql) 'S301103
(L L 01)569=Z L'(L 01)58Z=Z'(L L 01)664=8 AWE)xeln!
(ZI,01)96 L-=Z L'(ZI,01)L9-=Z'(6 Ol)Z£L-=811!Idn XeW
(Z I,01)£BL=Z-OH xen
(8-L-0'u!w) 0-9-0/1,L9=ZL'(8-1,-0'u!-) 0-4-0/9BZ=Z'le0!ue40aW/684=8 (az!s/ql) 'SNOLLOV3N
'ep!nlj uopelleisul
jaz!pgels 4l!m aouepo0oe u!'uoPow ssrul 6uunp pellelsu!aq 0-9-t£ON dS 4xZ 4912!3011S
6u!oejq ssojo paj!nbai pue sjaz!I!gelS Ietl spuawwom 481lW E"0N dS 4xZ S93M
-6u!oeLq oo 0-0-OL jo pa!Idde Alloaj!p 6u!l!ao p!&H GHOHO 109 £'0N dS 4xZ:Z9
s1e0!;Jan pua .1deox3.Z'ON dS 4xZ GHOH0 109
ldaoxa 'su!und oo 0-0-9 jo pa!ldde Alloanp bu!4lea4s poom leinjorulS 02iOHO d01 Z'ON dS 4xZ 0N01-10 d01
-QJNID"S -2I38Wn1
%OZ=1d q1011,3141519M (W-xweW) L00ZIdl/M0ZO9d aPOO 0'01, 1009
e/u e/u 8 Z0-0 (11)-OH 44'0 9M S3,& joul ssaAS daZ! 0,0 1109
09L £4£< 6-8 £4'0- (11)iJOA 69'0 09 SZ-L aseajoul jagwnl 001, 1001
06L/"Z OZ1W O4Z LLL< 6-8 61,'0- (11)1Jan 1,4'0 01 SZ'L aseaJOul saleld 0'0Z 1101
dRIJ S31Vld P(1 uaP/I (001) u! '7I330 ISO O-O-Z -°JNIOVdS Gsd)JNICIVOl
'X SIes40 aleld
-L
91
9-Z-LL 9£8 Z 0 L 4
9 6 M
E8
11 9x£
Z L L=4x4
£Z ZZ
Le
Z
1p
4
II ZL 00'9
Zl
L LZ OZ 9 6L 8L g
U!V/ =.Oao peol pea0 =4xE
9 9£L=aleos 114xZ —9x4
4 L 4 ZL-£-4 B L£ 0-Z-9 0 4 L
9-Z-L L 4 L-Z L 9£8 0 Z S 0 4 L
d IunPOMNL3zgZ—QN61,gVEeS km ZLfOn)18N11-Nff.�z6JIA8efmJLdnN1W4>ldz£VBO:OI _ LLLZE ld'WueS'Nddo s a Ii.n ue3u.
auro
L abed 4LOZ 9C:9Z:SL 9Z 6ny nt oul'sapsnpul JalW VLOZ 9 eW s OZS'L 4uud 4L0Z 8 eW s0Z9L:una
leuo!l o a0uaialatl qo[
L L AT
Ee SL£BZL
i
F11N 6+�0 Ad ad,(l ssru i ssrul q0f
VOL Zb # d `Pa!uem -W Lue!II!M
Ap
P d y
VOLZV OON o
�.0•••3SN3011
•w
pJepue3S (S)3SVO OVOI
ssrul VLOZ/8Z/80:9le(]'SZOOZOOV:ubaS(8
s!
yl to u6!sap pue s!s(leue a41 u!pasn sem lapow�4!xg pua Jagwah ,slaaq bu!pnlou!s4e9Jggol!d P!6u-!w9S,.(L
I,I,lu!of le 4!ldn ql LOZ pue
Z lu!of le)j!ldn ql gg'8 lu!of le u!ldn ql£1,t 6u!puelsyl!m to algedeo aleld 6uueaq of ssrul to(sJa4lo Aq)uogoauuoo Ieo!ueyoauJ ap!noJd(g
-suogoauuoo ssrul of ssrul Jol(s)Japn6 of Jalaa(9
sJagwew Jaylo Aue pue pJogo wo)Aoq aya ueamleq
lg II!m apM 0-0-Z Aq Ilel 0-9-£albueloaJ a aJa4m seeie Ile ui pJoyo wouoq aya uo lsdO-OZ 10 peol an!l a Jol pau6!sep uaaq sey ssrul s!41,(V
Speo!an!l J8L410 (ue yl!m luaJJnouoouou peol an!l pJoyo wolloq lsd 0 0 L a Jol pau6!sap uaaq sey ssrul s!41(£
6u!puod Jalem luanaJd of a6eu!eJp alenbepe ap!noJd(Z
09'L=10(]dub aleld 09 L=10(]
Jagwnl'umoys suo!loeaJ J01 Si83MW'8 sacuol pue sJagwaw Jol 0-0'pasodxa ly6u pue 3191 Janalgueo'auoz Z1,-O-L L 010-L 1,-6(1,)Joualul
'8-£-L 01 8-£-4(Z)Jou91x3'8-£-V 010-8-1,(1,)JOPOIul'0-8-1,0101-1,-(Z)Jou91x3 O-0 pue(Ieuo!loaip)S2i3MW'81,'0=!d00'.l3u3'0 dx3
'll'leo:314=anea'l;VZ=I 1144=8'114L=4'1SdZ t,=1(]08'1SdZ-V=-I(]Ol'4dw101,=PS8A(lsn6 puooas-£)4dw0£1,=11nn'OL-L 30Sd:Pu!M(L
(8) -S31ON
L6/84£-=8-9'06Z/0=6-9'01,L/89t-=0t-9 S83M
4Z£/98-=6-8'6Z£/V8-=01,-6'44£/69-=1,1,-01, GHOHO 108
umoys uatlm ldaoxe ssal J0(ql)09Z seoJol Ilb'--ual-xeW/-dwo0-xeyq-(ql) 'S33HOJ
(z[Ol)LOZ-=t t'(Z[Ol)49-=Z'(Z1,0l)£1,L-=94!ldn xeW
(Z1,0l)9L1,=ZzJoH xeW
(8-1,-O'u!w) 0-9-0/00L=1,1,'(8-t-O'u!w) 0-1r0/178Z=Z'leo!ueyoalnl/Z9b=8 (az!s/ql) 'SNOLLOV3N
ap!n6 uo!legelsul
J9z!I!ge3S 41!m aouepJ000e u!'uo!loan ssrul Bump pallelsu!eq
--
6u!oeJq sscuo paJmbei pue sJaz!I!ge1S 1e41 spuewwooei Na1!lnl_
- - -- - - - 0-9-t£'0N dS VxZ Sal H301-IS
8-9 ldp!w le mob 1, S83M £'0N dS VxZ S83M
bu!oeJq oo 0-0-0L Jo papdde Rlloei p bu!l!ao pftH GHOH0 108
£'0N dS VxZ:Z8
Sleo!1J8A pua ,jdeox3.Z-0N dS VxZ (IHOHO 108
ldeoxe 'su!pnd oo 0-0-g Jo pa!Idde RgoaJ!p 6w41ea4s poom IeJnlorulS (]aOHO d01 Z-0N dS VxZ (]aOHO d01
-OON13"S -N38Wn1
%OZ=ld 41£01, 346iaM (W-x!J1eW) LOOZIdl/OLOZ083 OL aP00 0' 1009
e/u e/u 8 LTO (ll)v0H 4£'0 8M S3A Joul ssailS daH TO 1108
081, 1789< 6-8 1,Z'O- (11)1JGA 917 0 08 SZ-I, aseaJoul Jagwnl O OL 1(]Ol
06 1,417Z OZ1W OVZ 666< 6-8 80'0- (ll)IJ8A L9'0 01 SZ't aseaJoul saleld O'OZ 1101
drdD S31V1d P/l u9p/1 (001) u! 1430 'ISO O-O-Z -JNIOVdS (sd)JNIOVO-I
S-L-O'L-£-O:Z 'X S38S.40 8181d
"-L --___- 0-6-VO-L-V
BILL 0-1,Lf ba 0LV
I I VxZ =Vx£
8
6 0Li1,
E8
11 9xc
LL=VxV
� L8
Z
L
91, 17x£
Zl
ZL 00'9
5 V
£ =ZVI? 11 4xZ =VxV
OZ
u!8/L Peol PeaO L
17,9c:I, 91e0S VxE ZLf 00'£
8-£-L 0-6-V 8 OL 0 8-£-V 0-11L
_ O-Z-L 1, 0-W6ZO—9 8-£-V 0-11V
O I KN6w3aAHdaNn I>I6LNZb4uLaLV50A3i-3H 3NNxAw-N RZz6)lA8ermo&dn NVigHdz£V8o:01
L 06ed KOZ L£:8Z:SL 8Z 6nV nyl cul'sauLsnPul HaLW 4LOZ 9 AeW s OZS'L 7uud VLOZ 8 m s OZS'L:unu LLLZ£lj'pJojuus Ajddng sjepgmg ueouawy
Ieuo!y o aouaJalaa qor
L L tpvdouovy 59 9L£BZL
St0 ON E-0 �( — ssru.L 1 q0f
ti01Zb # d `!.aa!uem •w Lue!ll!M
,..".Ma o %
:10 31vis
VOLZV•oN
'•3SN301
■w
PJepuelS (S)3SVO CIVO1
140Z/8Z/80:91e0'LZ00Z00V:ubaS(L
ssrul s!41 to u6lsep pue s!sAleue a4l ul pasn sem lapow Al!xg pue JagwaVq,slae4 6ulpnloul sMeaJggolld pl6u-IweS„(9
'6 P01 le 4!ldn ql 6L L
pue L lulol le 31!ldn ql£q'g lulof le)4!ldn ql 96 6u!puelsgllm to elgedeo aleld buueaq of ssrul to(saaglo (q)u0g08uu00 ILOlue4OaW aP!noJd(S
suolloeuuo0 ssrul of ssrul Jol(s)JapJl6 of Jalad(q
1sd0'O L=1408 41!m'sjagwew Ja4lo Aue pue pJo40 wolloq aql ueamlaq
3g II!m ep!m 0-0-Z Aq Ilel 0-9-£al6ueloei a aJa4m seeie lle u!pJogo wolloq a4l uo lsdO OZ to Peol anll a Jol pau61sap uaaq seq ssrul s!41.(£
speol an!l J0410 (ue ql!m luaunouoouou Peol an!l pJogo wolloq lsd 0,0 L e Jol pau6lsep uaaq seq ssrul s!41(Z
09'L=100 dub aleld Og L=100 Jagwnl:umo4s suopeaJ Jot S2i:MW 18 saoJol pue sJagwaw Jol O-0'pasodxa 146u
pue 1101 Jan8lque0:auoz ZL-O-L L 01 0-0-£(L)Joualul'0-0-£of 0-0-0(Z)Joualx3 0-0 pue(leuogoaj!P)S8:MW'8 L'0=!d0J''lou3:0 dx3
'll'leo'314=anea'gyZ=1'SS4=9'31S L=4'1sdZ-t,=1009'1sdZ't7=1001'4dw LM=Psen(lsn6 puooes-£)4dw0£L=llnn'0 L-L 30S`d:Pu!M(L
(L) -S31ON
990,96-2-Z OdOHO109
6£L/Z6Z-=OL-9'£££/Z96-=14-L OaOHO d01
'umo4s ue4m ldaoxa ssel J0(ql)OSZ saoJol lly-,ual-xetq/dwo0-zein!-(ql) 'S30a0:
(ZL 01)6L L-=6 01)£tr-=L'(ZL 01)96-=931!ldn xeW
(ZL 01)LSL=LzJOH xew
(9-L-O u!w) 8-8-0/V99=618-L-0'u!w) 01-0/6Z£=L'le0!ue40aw/Z8£=9 (az!s/ql) 'SNOLLOV3d
,9pInD uogellelsul
Jaz!I!gelS 43!m souepJ000e u!'uo.gmo ssnA 6uunp pollelsu!eq
6u!oeJq ssoJo paJ!nbei pue sJaz!l!gelS le4l spuewwooei Me.L!yy £'ON dS bxZ S93M
'6u!OeJq oo 0-0-OL Jo pe!ldde Alloomp 6u!l!ao p!6!d 0dOHO 109 £'ON dS t7xZ:Z9
sle0!>Jan Pua ,ldaoxa.Z'ON dS 4xZ OaOHO 109
ldaoxa 'su!und 00 6-M-9 Jo palldde(goaJ!p 6u!41eegs poom leJnlorulS 0dOH0 d01 Z'ON dS bxZ 0dOHO d01
-JNIOVM9 -1139vyn1
%OZ=1j ql 98 746!aM (W-x!JleW) LOOZIdL01,0Z09d 9P00 O OL 1009
e/u e/u 9 ZO.0 (11)zJOH LZ'0 9M S3A Joul ssaAS dad 0'0 1109
08L KZ< L-9 t,9'0- (11)V9A ZL 0 09 SZ-L aseaJoul Jagwn-1 O OL 1001
061./"Z OUN 04Z 6ZS< L-9 ZZ'O- (11)IJan £9'0 01 4Z'L aseaJoul saleld 0'OZ 1101
drdJ S311f1d Pn gap/I (o01) u! 1:30 'ISO 0-0-Z -ONl3VdS Gsd)ONICIVO-1
--- 0-C-0'a P3:9 'a P3'S L-£-O:L X slasl10 01e1d
L£f LL�L�l ZL-O-L
9-Z-LL L LL L ZLO-L
=9x4
9=9x9 L
b OL
b =VXV
6 =6x£
% 9L
L9
L
hL
Z
E t+xE
L Zr =bxE
t+x£
u!9l/9='Ua0 Peol PeaO S
0'9£:L=aleos II 4xZ zo 00'£
9-6-4 £L9 t+ L-L L-L
9-Z-LL £5 ZL L-LL-L
N Iuu4rLiuOHmE£e ISS9£Of341!3!HNA`^33Se6nAMf l-NT6uoefmULdnN{Wq)idz£V80:01
L aced 4L0Z 96:9Z:SL BZ�aroro nyl ouj'sa!Asn WI)Ia1W 4LOZ 8 eN s OZS'L:luud 4LOZ B eW 9 OZS'L.una LLLZE ld'wWueS'Nddng staging ue�uaur\/
leual o aouaJalad qoP
L L rp.douoyy Le SL£9ZL
IL
O oN 6xp r
ad( ssru ssru o
ti0d `!aa!uea •w Lue!ll!M
N�
45 FP
•�`�,ra o~•tib
�� 31t/1S 4
's tiOLZV•oN ?
d,,•,••.....••��
•�'�a/ •'u `■■'' ,7 piepuelS (S)3S`d0 0`70l
r'
17LOZ/8Z/80:a1ea'6ZOOZOOV:ubaS(L L
uo!loeuep Og£/1 iol peNoe4o woof o!1lV(OL
ssrul s!41 to u6!sap pue s!s(leue ayl u!pasn sem lopow p!xy pue jagwayy„s!aay bu!pnloul
sNeajgyol!d p!6u-!waS,(6
lu!of le)l!!dn ql g L L pue 6 lu!of le ll!ldn ql£Z1.bu!puels4l!m to algedeo eleld buueaq of ssrul to(sjaglo (q)uopoauuoo leo!ue40aw .g
ap!nad(g
suoiloauuoo ssrul of ssrul sol(S)Japn6 of Jalaa(L
8-L-wool of Aluo pa!ldde(lsd 0 0)peol peep pjo4o wolloq leuog!ppe pue(lsd 0.04)PeOI an!!PJoyo w0110e(g
1.L-OL-(s)jagwew uo(lsd 0-9)peol peep bu!l!ao(g
-sjagwaw ja4lo/ue pue pioyo wolloq a4l ueamleq
14 II!m ap!m 0-0-Z Aq Ilel 0-9-£a ftelow a aja4m sewe lie u!pio4o wolloq ay1 uo 1sd0 OZ to peol an!l a jol pau6!sap uaaq se4 ssrul s!y1,(4
SPeol an!i ja4lo (ue 4l!m luaLnouoouou peol an!l pjogo wolloq;sd 0 0 L e jol pau6!sap uaaq se4 ssnil s!yl(£
6u!puod J91em luanajd of a6eu!eip alenbape aP!nad(Z
09'L=104 dub aleid pg 1=100 jagwnl:umoys suo!loew jol SN3Mvy g saojol pue sjagwew jol 0-0'pasodxa ly6u
pue 491 J8n8!gue0'9uoz ZL-E-41 01 0-4-E(L)Joualul'0-4-E 01 ZL-L-O(Z)Joualx3 0-0 Pue(1eu0p0aJ!P)SN3MW'8l'O=!d00'-pu3:0 dx3
'll leo')J4=aAea'1147=1'4gt7=9'891=4'lsdZ'4=1409'lsdZ 4=1001'4dwLOL=Psen(lsn6 puooes-E)4dw0£l=llnn'OL-L 30SV:Pu!M(L
(L L) -S310N
£L 01./Z8 L-=L-4
'09Z/4 -=
9411-£'S£Z/564-=LL-L'ZSZ/9Z4-=01.-Z'SZZ/E9tr=0 L-8'Z88/691-=8-L Se3M
61.£/LS-=8-L OHOH0109
OL L/L E6-=Z L-4'OL 1./L£6-=Z 1.-9'LS/9 L E-=4-E
'1.9/OE£-=S L-£'1.9/OE£-qS -41.'L9/0££-=41.-£L'1.9/OEE-=E L-Z'89/ZZ£-=Z-L'OL L/£E8-=6-L ONOHO dei
umo4s ua4m ldaoxa ssel io(ql)OSZ saojol llV- ua1 xeyy/dwo0-xeyy-(ql) -S30NO3
(81.01)918=9'(8L 01)181=6neJ0 xeyy
(6 01)9 L L-=9'(8 01)EZ1.-=68!ldn xeW
(8-1-0 u!w) 0-9-0/EZ9=9'le0!ue439yy/909=6 (oz!s/ql) 'SNOLLOVEIN
,ep!n6 uopellelsul
iez!l!gelS 4l!m eouepj000e u!'uo!l3we ssrul 6uunp pellelsuf eq
6u!oejq ssojo paj!nbei pue siaz!i!gelS le4l spuewwooei>fal!yy
L L-0L'9-4.6-1. ldp!w le moN l 693M Z'0N dS 9xZ:MM
'6u!oejq oo 0-0-9 jo pe!!dde Ailoanp bu!!!ao p!6!a OHOHO 100 ,ldaoxa,E'0N dS 4xZ S83M
Sleo!V9A pua Z-0N dS 9xZ ONOHO 100
ldaoxa 'su!und oo 0-0-9 jo pe!!dde Alloanp 6u!4leogs poom leinlorulS ONOHO del Z'0N dS 4xZ ONOHO d01
-DNIOVNB -N39Wfll
%OZ=13 ql ZS L 146!aM 09£ Z69 8-L L 1.'0- 0g1V (vy-x!jlevy) L00ZldJ-tM0Z09d 9P00 TTL 1000
e/u e/u g 00.0 (ll)v0H SS 0 em S3.1 joul ssailS deN 0,0 1109
08L 968< 8-L 6VO- (ll)Yan 990 00 SZ'L aseajouljegwnl 0'01 1001
06M17Z OZ1W 04Z 666< 8-L £1.'0- (11)uan 990 01 9Z'L aseaJau!saleld 0'0Z 1101
drdD S31Vld P/1 ueP/I (ooi) u! 1330 'ISO 0-0-Z -9NI3VdS (lsd)ONI0VO1
Q-9-p0 O L Z _ 8�8 o-6$
o-4-£
=9x4 =4x4 =4x£ 4x7
S 9 L B 6
Zl L
N
=4xZ =4x4
11. C3 of
4 SLg 41. £L Z L
Z'L4:L=0103S =4x4 =4x4 11 4xd =4x6
0�P 0 OL Z 8-£-8
S-L-L L Z4> 0
B l L 11. 8
W IuOOsWOeIIONxLNl'01f9�LHN>18M3LslmWHZN4-NRZz6)LkeermE)idnNlWq>IdzEV80:O1
L aced KOZ 6£:BZ:SL 8Z Dntl nyl .cul'sautsnpul Aalvy bLOZ 8 Levy s OZS'L 7uud 4LOZ 8 Real B 0ZS'L:una LLLZ£ld'piWues'Nddns SJepllne ueyueua\/
le o eouejaleN qor
L L �lILV Ltl8 St£BZL
610 WJ 6M0 '
f4d 110 eddl eml -T,
qor
170M? # d `!.aa!uea •w LUe1II!M
a41H 0 j' r
:10 31vis
ms's V012V ION o
■r' ■■`` PepuelS (S)3SVO a`d0-I
4LOZ/8Z/80:e1e0'L£ooZoov:ubaS(1,l
uo!ioagap o9£I-1 Joi poi-4o wool O!11V(o L
ssnJi s!qi io u6!sap pue s!sAleue eqi u!pasn seen!apow ti!xg pue JagwaW,sleaq 6wpn!ou!s>eaJgyol!d p!6u-!waS„(6
L)u!of
le 4!Idn q!91,L pue 01,lu!of le 11!!dn q!£ZL 6u!pueisL4i!m io a!gedeo ale!d 6uueaq of ssrul io(sJaglo (q)uolloauuoo!eo!uegoauJ OP!nOJd(8
suogoauuoo ssrul of ssrul Joi(S)JOPn6 03 Jaiaa(L
6-8 woe of Aluo pe!!dde Gsd 0-0)peol peep pJogo wolloq!euo!1!ppe pue(isd 0 04)Peol an!!PJOg0 woiio9(9
E L-Z L'£I,-I,L'(s)Jagwew uo(isd 0 9)peol peep bu!!!a0(g
-sJagwew Jaylo Rue pue pJoyo wolloq ayl uaamlaq
14 II!M ap!m 0-0-Z Lg Ilel 0-9-£a!6ueloaJ a aJagm seeie Ile u!pJogo wolloq aq1 uo isd0 OZ io peol an!!a JOi p90!sep uaaq seq ssrul s!yl,(4
speo!an!!Jagio Aue qi!m ivaJJnowouou peol an!l pJogO wolloq isd 0-0 L e Jol peu6!sap uaaq seq ssnJl s!ql(E
bu!puod J91em luanaJd of 96eu!eJp aienbape ap!noJd(Z
09 L=100 dub ale!d 09-L=1O0 Jagwnl!umogs suo!loeei Jol Sa3MW+g seoJol pue sragwew Jol 0-0:posodxe ig6u
pue 1;a!J8n9!gue0:auoz Z1,-E-4L 01 0-4-E(1,)Jou91u!'0-4-E 01 ZL-1,-0(Z)joualx3 0-0 pue(!euopoej!P)Sa3MW'81,'O=!d0J'-!ou3'0 dx3
II leO:314=anea:1342=1'3154=8'49L=q'1sdZ'4=1008'1sdZ'4=1001'gdwL0L=Psen(lsn6 puooes-E)gdw0£L=11nn'0L-L 30SV:Pu!M(L
(L L) -S31ON
L8Z/66-=E 1,-4
'96/OLZ-=LL-E'OL6/8ZL-=8-9'96L/L9E-=ZL-4'L8L/404-=ZL-9'88L/Z6E=L L-6'E6L/4L!, =6-1, S93M
691,/9Z6-=41,-9'691,/9Z6-14-L171,L4171- 9L-4'4LL/Lt?t =9L-E'99L/6Z8-=0L-1, 0Z!OHOd01
'umogs uagm idaoxe ssal Jo(ql)09Z saOJoi pV-'ual xeVyl dwo0 xen-(q!) 'S33a03
(81,01)91,8=L'(91.01)L8L=0 L neJC)xe"
(6 01)91.L-=L'(9 01)EZL-=01,11!Idn xeW
(8-L-0'u!w) 0-9-0/EZ9=L'leo!uegoaW/9o9=oL (oz!s/ql) 'SNOLLOV3N
'ap!n uo!leligisul
Jaz!!!geiS q1!m eouepJoOoe u!'uopoaJe ssrul 6uunp pagelsui eq
bu!oeJq ssoJo paJ!nbei pue sJaz!pgeiS 1eg1 spuawwooaJ 3191!yy
£L'ZL'LL:(s)lf leeoeJ9 L S1N!Of
L-9'0L-L idp!w le moa L S93M Z'oN dS 9xZ 0LM
6u!oeJq oo 0-0-01 Jo pa!!dde Ijoanp bu!I!ao p!&a 0aOHO 109 ,1d9Dx3.E'oN dS 4xZ 693M
S!eo!lJan pua Z'oN dS 9xZ OaOHO 109
lda0x8 'su!und oo 0-0-9 Jo pa!!dde AIjoaJ!p bu!gleags poom!eJniorulS 0aOHO d01 Z ON dS 4xZ OaOHO d01
-ONI3V118 -b3swn-i
%OZ=13 ql 9LI,:10meM 09E 088 6-8 L V0- ofAV (W-x!jleW) L00ZIdL0l0Z083 ePOO 0,M 1009
e/u e/u L 00'0 (11)v0H 04,0 9M S3A Joul ssaJ3S daa 0'0 1109
08L Z98< 6-8 OZ-0- (11)IJOA 49'0 09 9Z'1, aseaJou!Jagwnl 0'01, 1001
061,/"Z OZ1W 04Z 666< 6-9 EV0- (ll)Pen ZE-0 01 5Z'I aseaJOu!saleld 0'0Z 1101
dPJ9 S31Vld P/l uep/I (-I) u! '1330 ISO O-o-Z -EJNIOVdS (!sd)ONIUVOI
-
8-
=9x4 =4xY =4xE 114xZ
9 L 9 6 01,
WI 1,8
°°
b
L
N
qxZ I 14x4 =4x4
ZL E1, LL
:8L
u!9VI,='9a0 Peol PeaO S 91,q E 91, Z L
L'L9:L=ele'S =4x4 =4xE =4xE 11 4xZ =4x£
o-s-o o-oL-z z1,-1,-4 zt-1,-4 o-rE
9- L L 95-41, 9-L-LL ZL$L 0-4-£
1 Iu1wOno=iPuX!HXO)IXMEIX3ndGjxF eXwnnOe30LV-NRZz6U9ef MJLdnN►Wq>idzcvw:OI
L abed VL
Oz o4:9Z:9 L 9Z Bnv n4l oil'saulsnPul HaLW bLOZ 9 XBW s OZSL 4uud 4LOZ B BW s OZTL:una tLLZE ld'Wa4ueS'f4ddnS saegm8 us-a w
!euog o eoueJeiea qoE
t L 3.w M SLEBZL
Nd �1D edA i ssru issti
i�O1Zti # d `!aa!uea •w uae!II!M
101VI>
y .
�o aldis �4
? VOLZVION
VA'. 3SN3�Il
.IN U1••
(AW=9L(d)6W=9L(d)69tl=b1(d)99tl=£L(d)6vv-=ZL(d)Zvv-=L(d)Z9£"=9(=I)ZZ£-=6:IJGA
(QI)speol pele.4—uoO
wePuelS (S)3SV3 dVOI
Z-6Iu91ZGAftO—". W—VYdO�J�+LX9f1uLVf8-NRZz6ugefm`Ldf3NlWQ�1�sVB�dl un /1ZE ld'w eS'NddrS saeging ue�ueiW
d vLOZ L4 BZ S L 8Z IXM �u '�!u5^Pul)pLw vtoz s •w S oz9�L lw�d fr a Bw ozs't a
leu o e�uare;ea qor
< < ,ew!qi�s�a eve 9�eazl
6+
CZo ON a '
edA i ssru 1nng
VOLZt, # 31 d 1aOWH -W Lue1111M
.•
�0 31d s
VOLZV•oN s
%%3SN3011
.w ■.
PJepuelS (S)3SVO UVO-1
4LOZ/9Z/90 aleu'S£OOZ00`d ubaS(L
-ssrul s!4l to u6!sap pue s!s(leue a41 u!pasn sem lepow!q!xg pua jagwayy,shay 6u!pnlow sMeajg4Ol!d p!6u-!weS„(g
'£lu!of le g!ldn ql Z9 pue
4lu!of le u!ldn ql 09 1,'S lu!olle g!ldn ql 1g 6u!puels4l!m to algedeo aleld 6uueaq of ssrul to(sj94lo (q)uogoauuoO leO!ue4Oaw aP!Aad(S
-suo!loeuuoo ssrul of ssrul jol(s)japn6 of japes(4
sjagwew ja4lo (ue pue pjogo wolloq a4l uaamlaq
14 Mm aP!M 0-0-Z Aq Ilel 0-9-£916ueloaj a aLa4m sewe Ile u!pioLyO wolloq ayl uo lsdO OZ to Peol aA!l a jol pou6!sep uaaq se4 ssrul s!41.(£
'speol aA!l J9410 (ue 41!m luaLnouoOuou peol aA!l pjo4o wolloq lsd 0-01 a jol pau6!sap uaaq se4 ssrul s!41(Z
09'1=-10a dub aleld 09 L=-10a jagwn-1'umo4s suo!loeai jol S2I IMW 8 sawol pue sjagwew sol
0-0'pesodxa gal!eo!lJaA pua'pasodxe 146u pue gal J9nal!lue0'9uoz(Z)Joualx3 0-0 pue(leuopoai!P)S2i3MW'9 L'0=!dOJ''I0u3'O dx3
'II 7e0'g4=anea'g4Z=-1'gS4=9'115 L=4'1sdZ 4=1039'1sdZ'4=lOOl'4dw 1,0 L=PseA(lsn6 puooas-£)4dw0£L=11nA'O L-L 30SV:Pu!M(1,
(L) -S310N
umo4s ua4m ldaoxa ssel io(ql)OSZ saojol lIV--ua1'xepy/dwo0'xeW-(ql) 'S332l03
(01,3-1)9E=£'(01,01)66=4'(6L 0-1)LZZ=SAeJOxeyy
(61.O-1)Z9-=C'(ZL O-1)0SL-=4'(9 3l)L9-=Sg!Idn Xen
(ZL 0-1)LZL=9voH xepy
leo!ue4oayy/9S-=£'ieo!ue4O9yy/Z-=4'(9-L-0-u!w) 45-0/SLZ=S (oz!s/ql) 'SNOLLOV3u
'ap!n uopegelsul
jaz!l!ge1S 41!m eouepj000e u!'uo!loaja ssrul 6uunp pellelsu!eq
6u!oejq ssojo paa!nbai pue sj9z!l!ge1S 1e41 spuawwooei Aal!W
'6u!oeiq oo 0-0-01 jo pa!Idde Alloeip 6u!l!ao p!6!a GHOHO 109 £ON dS 4xZ S03M
'Sleo!yaA pua Z ON dS 4xZ MONO 109
ldeoxe 'su!und oo 4-11-0 jo pa!ldde(gOanp bu!4leegs poom leinlorulS GHOHO d01 Z'ON dS 4xZ GHOHO d01
-ONIOVUS -m38Wni
%OZ=ld ql 6:14618M (W-x!AeW) L00ZIdL0L0ZO9d SPOO 0"0L -1409
e/u e/u E S0'0- (-11)vOH 00'0 9M S3.1 foul ssai1S daH 0'0 -1-109
091, 666< S 00'0- (-11)IJOA ZZ'0 39 SZ'L aseajouljegwnl OOL -1431
061,/44Z OZ1W 04Z 666< S 000- (Tl)>JM 940 01 9z,I, SSMOulSaleld 0'0Z 1-131
dIM9 S31V'ld P/-1 ILaP/I (-I) u! 1d30 ISO 0-0-Z -DNIOVdS (1sd)E)NIUVO-1
4-L L-0
4iVo
Le
N
w N LA3
b
L
Li
Ll
�1
z
114x£
E dL 00'9
9'9 L:L=aleoS
4LL-0 ZL4L
ZL-4-L-
f IUAbXzA!OZuiu£-16LPxJLH)I—iJ9!n61WLAW-NRZz6MkgermOZdnNlWgNdz£t/9O:01
L e6ed YLOZ Z>:9Z:SL 9Z 6rry nyl'oul'soulsnpul Mel!W bLOZ 9 AeW s OZS'L:Luud 6LOZ 9 LeW s pZ91:una LLLZE l_A'WolueS'Nddns sdapling ueoua W
leu o aouejalaa qop
L Z N3dO-X3W Wo SLE9ZL
SZo oN&A0
f"T edA —1 ssrul
VOLZb # d `!.aa!uem •w uie!II!M
6180
(�
�Q 31t11S ��,
ms's VOLZV ION
3SN301-1
Iw ■��
PepuelS (S)3SV0 aV01
t7LOZ/8Z/80 81e0'L£OOZOOb':ubaS(L
-ssnJ1 s!41 jo u6!sop pue s!s(leue 841 u!pasn sem lapow 4!xg pue Jagwa!ry„shay 6u!pn!ou!sNeaJggoj!d p!6u-!weS,(9
-£lu!of le 4!ldn ql£L pue Z lu!of le u!ldn ql 96 bu!puels41!m jo algedeo aleld 6uueeq of ssrul jo(sJa4lo (q)uogoauuoo leo!ue40aw ap!AOJd(9
suogoouuoo ssrul of ssrul Jol(s)JapJ!6 of Jajaa(p
sJagwew Ja410!ue pue pJoLio wolloq a41 uaamlaq
14!I!m 8p!m 0-0-Z Aq Ile1 0-9-£916ueloaJ a aJa4m seaJe lie u!pJogo wolloq 841 uo jsd0 OZ 10 Peol 9A!I a Jol pau6!sap uaaq se4 ssrul s!41,(£
Speol an!!Ja410 Aue 41!m lueunouoouou Peol 9A!l PJO43 wolloq;sd 0 0 L e Jol pau6!sap uaaq se4 ssnJl s!41(Z
09 1=100 dub oleld 09 1=100 Jagwnl'umogs suogoew Jot SadMyy 8 saaol pue sJagwaw Jol 0-0'pasodxo 146u
pue)491 Janal!lueo'euoz YL-L L-L 010-13-L(L)JO!Jelul'0-8-1,010-17-L-(Z)Joualx3 0-0 pue(leuogoaJ!13)SHAMW'8 L-0=!d00`!Ou3'0 dx3
'II le0'84=anea'1jt7Z=l'1j44=9'49 L=4'jsdZ'17=1409'jsdZ't,=1001'4dw 1,0 L=PseA(lsn6 puooes-£)4dw0£L=11nA'O L-L 30S`d:pu!M(L
(L) -S31ON
'umo4s u9W ldeoxe ssa!Jo(ql)09Z saoJol IIV- u91 xeyy/dwo0 xeyy-(ql) -S30NO:1
(L 01)6E=£'(£0l)ZE=4'(L 01)98 L=ZAeJO xeyY
(ZL O-I)EL-=C'(ZL 01)96-=Z4!Idn xeW
(Z I,01)9£=Z-OH xeyq
!eo!ue408VY/6£=£'leo!ue4oaW/17L=17'(8-L-0-u!w) 0-9-0/98L=Z (ez!s/ql) 'SNOLLOV3U
'epjn6 uopellelsul
iez!l!gelS ql!m aouepxme u!'uogma ssrul 6uunp pagelsu!aq
6u!oeJq ss=paJ!nbaJ pue sJaz!I!gejS 1e41 spuewwoow>la1!yy
-6u!oeJq oo 0-0-OL Jo pa!idde Alloeip 6u!l!ao pft! j CIHOHO 109 Z'ON dS 4xZ OHOHO 109
'su!und oo O-O-Z Jo pa!idde AIloei p 6u!41eogs poom leJnlorulS ONOHO d01 Z'ON dS 4xZ OaOHO d01
-ONIOV IS -2l38Wnl
%OZ=1d gl 81461eM (W-xL4eW) LOOZId1JOLOZ093 81300 0'01, 1009
e/u e/u £ 000 (11)zJOH 00'0 9M S3.1 Joul ssaJlS daa 0'0 1109
08L 666< L 00'0- (11)IJOA £0'0 09 9Z-L aseaJoul Jagwnl 0'01, 1001
0611,1"Z OZ1W OIrZ 666< L 00'0- (ll)1JOA I,Vo 01 9Z'L aseaJoul sale!d O'OZ 1101
drdS S31V°'Id P/1 aep/I (0O0 u! '133(3 'ISO O-O-Z -ONIOVdS (jsd)ONKNO-1
011-Z
O-O-Z
=4x£
4
L8
l
Ll
z
ZL 00'£
e a
91L=aleOS
O-O-Z O-C-L
011-Z 0 tr L
I If-WOIZx6d3)It7SIzl68d3olnoeLdZOSEWMHOul4(:t-NRZz6)lA8erNVLdnNjWgHdzeV :a1
L abed 6LOz 6>:8Z5 L 9z en`d n41 'cul,-.ulsnpul Ha1W 4LOZ 8 AeW s OZ9'L_luny YLOZ O Rept's OZ9'L:una LLLZ£ld'Wc1ue8'Nddns sdappe uewawy
leu o eouaJajaa qor
L Z uedo-ver jZro SL£BZL
LZO ON B+a
Nd Jtlo ads(i ssni i ssrul o r
VOLZb # d !JOIUea •w Lue1111M
••`6111o�•s
'ado 31vis
's VOLZV•ON o
d�'.�3SN301 -''\�
ow �.
pJepue3S (S)3SVO 4V01
6LOZ/8Z/80:9)e0'6£OOZOOb':ubaS(L
ssrul s!4110 u6!sep pue s!s(leue 941 u!pasn sem lapow (1!x4 pue JagwaW„s19a4 6u!pnlou!sMe9Jg4ol!d p!bu-!w9S„(9
6 lu!of le g!ldn ql L6
pue£lu!of le)j!ldn ql 8L'S lu!of le g!ldn ql LZ 6u!puelsgl!m 10 algedeo aleld buueaq of ssrul 10(sJa410 (q)uo!loauuoo le0!ue4oew 9p!noJd(S
-suopoauuoo ssrul of ssrul Jol(s)JapJ!6 of Ja1aa(6
sJagwaw Ja410 (ue pue pJogo wolloq aq uaamlaq
19 IIlm eP!m 0-0-Z Aq Ile1 0-9-£albueloaJ a ojoL1m sewe Ile u!pJo4o wolloq 941 uo 1sd0 OZ 10 peol en!l a J01 p9u6!s9p uaaq se4 ssrul s!qi.(£
speol en!l Ja410 (ue ql!m 1uaunouoouou peol an!I pJo4o wolloq 1sd 0 0I,a Jot pau6!sap uaaq se4 ssnJ1 s!41(Z
09'L=100
dub aleld 09*L=100 Jagwnl:umo4s suopoe9J Jot S2i3MW g saaol pue sJagwaw Jot 0-0:pasodxa 3L81 leo!1Jan pua pasodxa 1L4
pue 1191 Janalpueo:auoz 8-0 L-Z 0l 6-L-L(L)JOualul'6-L-L 03 ZL-6 L-(Z)Joualx3 0-0 Pue Qeuo!1oaJ!P)S2i3MW'8 L'0=!d00''pu3:O dx3
11'180'316=anea:1142=1'3154=9:31SL=4 3sdZ 6=1009'LsdZ 6=1001'4dw LOL=Psen(1sn6 puooes-£)4dw0£L=11nn'0L-L 30S`d:Pu!M(L
(L) -S310N
umogs ua4m ldaoxa ssal Jo(ql)09Z seoJol IIV--ual-xeW/dwo0 xeW-(ql) -S3O2iO3
(0L 01)LS=6'(LI,01)6L=£'(L O-I)BZZ=SneJO xeW
(Z 1,01)Lb-=6'(Z1,01)8L-=£'(8 Ol)LZ-=511!ldn xeW
(ZL Ol)Z9L=9zroH xeW
leo!ue409W/SZ=6'leO!ue409W/89=£'(8-L-O'u!w) 1-9-0/8ZZ=9 (az!s/ql) 'SNOLLOV3U
--- ,ap!n uo!lel!elsul
J9z!l!ge1S 4pm eouepJ000e u!'uopowe ssrul 6uunp pallelsu!aq
6u!oeJq ssao paJ!nb9J pue sJ9z!l!ge1S 1e41 spuawwooeJ Me1!yy
-6u!oeJq o0 0-0-OL Jo pa!ldde Allo9J!p 6up!eo p!6!a GHOHO 109 £'oN dS 6xZ S93M
sleo!1Jan Pug Z'oN dS 6xZ OZIOHO 109
ldaoxa 'su!und oo 6 L L-Z Jo pa!ldde AIloaJ!p 6u!41ea4s poom leJnlorulS 02i01-10 d01 Z'oN dS 6xZ MA01-10 d01
-ONIOVUS -838Wf11
%OZ=13 41 SL 346!aM (W-xu3eW) L00ZId-L/0L0Z0UJ 81300OO1009
e/u e/u £ OZ O- (11)zJ0H 00'0 9M S3A Joul ssaJ3S daH 0'0 1109
081. 666< 91, £0'0 (11)IJ8A 86'0 09 SZ'L aseaJoulJagwnl 0'01. 1001
06L/66Z OZiW O6Z 666< 917 £0'0 (11)1J9A 06'0 01 9z,1. aseaJOul saleld 0'0Z 1101
drdD S31V Id P(1 uaP/I (ool) u! '133(3 'ISO 0-0-Z -ONIOVdS Usd)ONICIVO-1
- --- — a P3'0-£-O:Z 'X s19s310 aleld
PLL-Z
=9x6
6 S
L8
NN
L
O
LL Z
19x6
9
ZL 00'9
E
9£Z:L=aleas
I 6Z I Z
ALL Z ZL-YL-
H IUD^PS06fE41H48,g!Wllf!Z 660U8wb6XPOVsnE-NRZz6)lA8ermE)Ldf1NLN�gNdz£`d8o:01
L abed YLOZ 4682 SL BZ ny ny1-oul'sauysnpul McLW 4LOZ 8 AeW s OZ9'L.luud 4LOZ 8 eW s oZS'L:un LLLZE l3'pJoiueS'Nddns sdapline ueouawV
leuop o eoueJalaa clop
L Z N3do-HOW v£ro SLEBZL
6ZO ON 6«a
edr( SSti SSfL
tiOLZ # d !Jaiueu •w Lue!11!M
'; :1 31v1S
VOLZV OON v
'.03SN30Il
■w
pJepuelS (S)3SV3 avo-i
4LOZ/8Z/80:01e0'L400ZOOV ubaS(8
-ssrul s!41 10 u6!sep pue s!sAleue a4l u!pesn sem lapow 41!xg PUG Jagwaw,shay bu!pnlou!s>e9Jg4ol!d p!6u-!waS.(L
y lu!of 1e)pdn ql 8Z pue
£lu!of le 4!ldn ql g0l'g 1u!Of le g!ldn ql SZ 6u!puels4l!m 10 91gedeo aleld 6uueaq of ssrul 10(sJa4lo Aq)uo!loauuoO 180!ue4O9w 9P!noJd(9
suo!loauuoo ssru;of ssnA Jot(S)Jepn6 01 Jalaa(g
sJagwaw Ja410 (ue pue pJo4O wolloq 441 uaamlaq
14 11!m eP!m 0-0-Z Aq Ilel 0-9-£albuepaJ a aJa4m seeie Ile u!pJo4o wo)Aoq 941 uo 1sd0 OZ 10 peol an!l a Jot Pau61sap uaaq se4 ssrul s!41.(6
Speol an!l J84lo (ue 41!m lueunouoouou peol an!l PJOL13 wolloq 1sd 0 0 L e Jot pau6!sep uaaq se4 ssrul s!41(£
'paleopu!es!nua4lo ssalun saleld OZlw aJe saleld II`d(Z
09'L=100
dub aleld 09 L=1O0 Jagwnl:umo4s suopoeaJ Jot SHjMW 8 sooJol pue sJagwew Jot 0-0:p9sodx9)4a1 leo!1Jan PUG'posodxe 146u
PUB 1101 Jan0l!lue3:9uoz 8-OL-401 JL-1,(L)Joualul'4 L L 01 ZL-t l,-(Z)Joualx3 0-0 Pue(IeuO!loaJ!P)S2H3MW'8L-0=!d0J'-lou3:0 dx3
11'leo 11q=anea:11bZ=1'31Sb=8'l1S1=4'1SdZ 4=-1008'LsdZ'4=1001'4duJLOl=Psen(1sn6 puooas-£)4dw0£L=llnn'OL-L 30SV Pu!M(L
(8) -S310N
IWZSZ-9-Z GH0H3 d01
umo4s u@L m ldeoxe ssal J0(ql)09Z seoJol IIV--ual xew/dwo0*xe"-(ql) 'S33M03
(£01)06=4'(L L 0-1)04 L=£'(L 0l)L6Z=S neJO xeyy
(ZL 01)8Z-=4'(ZL 01)90L-=£'(ZL 01)SZ-=S4!ldf1 xeW
(Z L 0l)L6 L=S zJOH xe!N
IeO!ue4OaW/09=4'IeO!ue4OeN/4ZL=£'(8-L-0'u!w) t-9-0/L6Z=9 (9z!s/ql) -SNOl13V3H
ap!nb uopel!elsul
jez!l!gelS 41!m 93uepJ000e u!'uogoeja ssrul 6uunp pallelsu!aq
6uioeiq ssao paJmbaJ pue sJazil!gelS le4l spuawwooei Noi!yy
'6u!oeJq oo 0-0-OL Jo pe!ldde lloaJ!p bu!pao p!6!a GH01,10 109 Z ON dS 17xZ S83M
sleo!1Jan PUG Z'ON dS 4xZ 02101-10 109
ldaoxe 'su!und oo I,l,L-q Jo pa!ldde Ll1oej!p 6u!yleeL4s poom leinl3rulS OaOHO 6101 Z'ON dS I'xZ OHOH3 d01
-JNIOVa8 -u3ewn1
%OZ=13 q1 LZ 746!aM (W-x!J1eW) LOOZIdL01,0Z0e3 aP00 O'M 1008
e/u e/u £ 94'0- (-11)-OH 00'0 8M S3A Joul ssaJlS d9H 0'0 1108
£4L/L8L HOZ1W 081, SZS< S-4 1,VO 01)IJ@A 4L'O 09 SZ-L asecuoulJagwnl 0'01, -1001
06L/"Z OZ1W Ot7Z £St- 9-4 £L'0 (-l-*JeA I'L'O 01 SZ'L aseaJOulsaleld 0 o 1101
drdS S31Vld P!1 gap/l (301) u! '16134 IS3 0-0-Z -QJN13VdS Usd)ONIOVOI
- - - --- Zt-t-00-Z-0:Z X slas110a1e1d
b-L L-V
I I HOZ1W 9x9
b 5
t9
A L
Ip Ip P
N V1
b Z
9 11 Yxt'
Ll
L
ZL 00'9
£'8Z:L=aleo'S
YtL V ZL-V-L
4-t v ZL!rt
S' IWHEieioS183Szl1lfl3zn!bSg9JIIZHJ4gPXzPA04X-NR6xA9ermoidnmvygNdz£V83:a1
L abed 4L0Z 94:9Z:SL 9Z 6ny nLLL-oul'sauLsnpul Ha1W V LOZ 9 eW s OZS L:luud 6LOZ 9 AeW s OZ9'L:una LLLZE l_q'pialueS'JgddnS s�eplmg u-p—v
leuo!l o aouejejaa q0f
L Z N3dPN�Vf VSfo 9LE9ZL
L£0 ON�O '
Aid An 4a 1 ssrL O
tiOLZt� # d `!aa!uea •w uae!II!M
g Bins �4
VOLZVON
.' . ;
Elm
pJepuelS (S)3SVO 0V01
4LOZ/qZ/80 91eO'Z40OZOOV:ubaS(8
-ssrul s!yl;o u61sep pue s!sAleue a43 u!pasn sem lopow 4!xg pue jagwalnl„shay 6u!pnlou!s�eajggol!d p!6u-!waS„(L
6
lu!o!le u!ldn ql 94Z pue Z lu!o!le l;!ldn ql 40£bu!puels43!m;o elgedeo aleld 6uueaq of ssnul;o(sjaylo (q)uopoauuOO IeO!ue4Oaw ap!nad(9
-suo!loauuoo ssrul of ssrul jol(s)japn6 of ja;aa(9
;sdO 0 L=1008 411m'sjagwaw ja430 (ue pue pio4o wolloq 943 uaamlaq
3g Illm 9P!m 0-0-Z Aq Ilel 0-9-£al6ueloaa a aiagm seaae lie u!pjo4o wolloq 943 uo;sd0 OZ 10 peol an!I a JO;Pau6!Sap uaaq sey ssrul s!41.(4
speol an!l Ja43o l;ue 43!m luaLnouoouou peOl an!l pjo4o wolloq;sd 0-0 L a jol pau6!sap uaaq se4 ssrul s!41(£
09'L=100 dub
aleld 09 L=100 jagwnl:umoys suo!loeaj Jo;SZIdMn g ssojol pue sjagwaw jol 0-0:posodxe 146u pue 1191 Jana!!lueO:auoz 9-L L-LL
of 8-L L 4L(Z)Joualx3'8-L L14 010-2-L(L)joualul'0-8-L of O-t,-L-(Z)joualx3 O-O Pue(leu0paip)S2idMW18L'0=!d0`J`lOu3'O dx3
11'leo'314=anea:3192=1'liS4=9'1lS L=4'iSdZ'4=1008'isdZ 4=1001,u6!sap s!yl jol pajap!suoo uaaq aae 4spe0lnanil;oa peo eiequn(L
(8) -S310N
98£/LO£L-=6-L'9qZ/9E-=OL-9'Z9L/ZLL-=ZL-9'69Z/EZ4-=ZL-4 S93M
006/89Z-=M-6'ZL6/Z6L-=LZ-0L'Zt6(Z6L-=LZ-LL'UW6L-=ZL-4'££SL/ZZb-=ZL-Z O60HO109
L L4/89 L L-=6 L-L'LE4/OLO L-=6 L-9'L64/68£L-=8 L-9
S84186£L =8L S'ZL4I884L =5 4'064/S£SL=LL 4'994/S991 =LL£'OILS6=£Z OaOHO dOl
umo4s ue4,vm ldaoxe ssel io(ql)OSZ saojol IIV--ual-xeIN/-dwo0-xe!ry-(ql) -S3O210j
(ZL 0-0172-=6'(ZL Ol)40£-=ZS!Idn XeW
(L L 01)9LL=Z-OH xe!N
IeO!uey09w/640L=6'(8-L-O'u!w) 0-9-01££LL=Z (oz!s/ql) 'SNOLLOVEIN
-apm uo!lel!elsul
Fjez,j�! q yl!m aOuep�oOOe u!'uo!l0aja ssruq 6uunp papelsu!aq
urssauo pawlnbei pue siazrilgelS leyl spuewLuOOaJ 1811A 0-9-L£'ON dS t4xZ 1191 83011S
'6u!oejq oo()-Z-Z jo pe!ldde Alloeip 6u!I!eo p!61a GHOHO 109 E'ON dS 4xZ S93M
s!eOI Jan pua Z'ON dS 4xZ OaOHO 109
ldeoxa 'su!und 00 9-L-£Jo pe!Idde Alloejip bu!43ea4s poom IeinloMS (MOHO d01 Z'ON dS 4xZ GHOHO d01
-ONID"El -H39Wn1
%OZ=1d ql 6El:ly6!eM (W-xuleW) LOOZldJJOLOZO9d 9POO O'M 1(109
e/u e/u 6 90-0 (11)-OH 6L'O OM S3L. foul ssailS daa . 0'0 1109
08L 4417< ZL-OL LL'O- (11)P9n 860 09 SZ'L aseajouljagwnl 0-M 1001
06L/44Z OZ1W 04Z 09L< ZL-OL Z4'0- (11)U9n 99'0 Ol SZ L aseaLoul Seleld O'OZ 1101
dRID S3LVld P/1 uep/I (ool) u! 1330 'ISO 0-0-Z -E)NIOVdS (lsd)'JNIOVOI
_ e P3'1,-4-OZ X slas,40 aleld
5 9 9 9-0 L-6 - 4-0-0 L
0-9-92 L L-0 L-6 L 9-0-0 L
119xE
=9xE =4xE 17XE —4XE
6 OL LZ 11 ZL
Z
LL E
4xE
9
114XZ
OZ q
L
4xE 9 \\4xZ
4xE
6L 9L
9 z LA 00'9
u!9 L/9= 990 Peol PeOG =4x4
4'67:L=aleDS
0-4-L 9-L-L 0 4 L
8L4 0�L 9-1,1,4L BLL OYL=
OS-9Z "-ZZ
3 IVMH68SIds6ZeWOb)I zv%[Z-HLM4L1Z1Z]X11-NRZz6UOI?rm LdnN;WgNdzEV9o:0IdWolu
1 LLLZE ' eS'Nddnss1agingueouawv
L G&d 7LOZ LOW:9L 9Z 6nv n41'oul'seutsnpul 3IaLW 4L0Z 8 Real s OZ9-L Mud 4LOZ 9 AVA s OZ9'L:un21
zeo oN 6«a
aop o StE9ZLleual o aOuaja;aa 401, L �2.1--
ss
cuss runs We Ng No 106
728315 HA2 Roof Special Girder 1 -7t
Job Reference o tional
American Builders Supply,Sanford,FL 32771 Run:7.520 s May B 2014 Pred:7.520 s May 8 2014 MTek Industries,Inc.Thu Aug 2815:29:13 2014 Page 2
ID:c8A3zpKbMfNUP?GwJa8Yk9zZjjN-iT67VYtB?goJPctZEKKH 1 TPLkrZwlhmagEzgPFyjHzq
LOAD CASE(S) Standard
1)Dead+Roof Live(balanced):Lumber Increase=1.25,Plate Increase=1.25
Uniform Loads(plf)
Vert:1-3=-60,3-5=-60,5-6=-60,6.-8=-60,13-17=-20
Concentrated Loads(lb)
Vert:3=35(F)12=22(F)21=6(F)23=6(F)24=6(F)25=6(F)27=-0(F)28=-0(F)29=-0(F)30=-165(F)
40 yl M.
�j No.42704
i STATE OF
L n 11DPa.
William M. Ranieri, P c # 42704
Job cuss I ruseype Ply
'
728315 H5 Hip 1 1
Job Reference(optional) Dwg No 164
American Builder's Supply,Sanford,FL 32771 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MTek Industries,Inc. Thu Aug 2815:29:12 2014 Page 1
ID:c8 3zpKbMf 4UP?GwJa8Yk9z2Y11'N-EHYIICsZENgSnSlNhdp2UGs9JRBzOHBRbaE6tpy)Hzr
5 0 0 9-8-8 14-5-0 18-9-8
5-0-0 4-8-8 4-8-8 4-4-8
Scale=1:30.8
Dead Load Dell.=5/16 in
4x4=
3x4= 4x4=
6.00 12
3 16 17 4 18 19 5
20
15
4x4 4x4
2 6
1
�.] N
Ogl 10 9 a 7
34 11 3x4= 3x4 3x10= 2x4 II
5 0 0 + 14-5-0 18-9-8
5-0-0 9-5.0 4-4-8
Plate Offsets(XY)— 11:0-2-12.0-1-13)
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.45 Vert(LL) -0.17 8-10 >999 240 MT20 244/190
TCDL 10.0 Lumber Increase 1.25 BC 0.72 Vert(TL) -0.45 8-10 >492 180
BCLL 10.0 ' Rep Stress Incr YES WB 0.31 Horz(TL) 0.03 7 n/a n/a
BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:92 Ib FT=20%
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-8-9 oc purlins, except
BOT CHORD 2x4 SP No.2 end verticals.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 9-1-14 oc bracing.
SLIDER Left 2x6 SP No.2 1-6-0 MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection,in accordance with Stabilizer
Installation guide.
REACTIONS. (Ib/size) 1=746/0-6-0 (min.0-1-8),7=746/Mechanical
Max Horz 1=57(LC 11)
Max Uplift1=-173(LC 12),7=-174(LC 12)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 1-2=-374/80,2-15=-1112/381,3-15=-1043/389,3-16=-944/393,16-17=-944/393,
4-17=-944/393,4-18=-871/351,18-19=-871/351,5-19=-871/351,5-20=-942/349,
6-20=-1023/341,6-7=-727/282
BOT CHORD 1-10=-291/931,9-10=-404/1150,8-9=-404/1150
WEBS 3-10=-19/333,4-10=-310/144,4-8=-379/185,5-8=0/265,6-8=-194/807
NOTES- (9)
1)Unbalanced roof live loads have been considered for this design.
2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf;BCDL=4.2psf;h=15ft;B=45ft;L=24ft;eave=4ft;Cat.11;
Exp C;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)0-0-0 to 3-0-0,Interior(1)3-0-0 to 5-0-0,Exterior(2)5-0-0 to 18-7-12
zone;cantilever left and right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip
DOL=1.60
3)Provide adequate drainage to prevent water ponding.
4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6)Refer to girder(s)for truss to truss connections.
7)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 173 Ib uplift at joint 1 and 174 Ib uplift at joint
7.
8)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
9)Segn:A0020114,Date:08/28/2014
LOAD CASE(S) Standard
'LICENSE
N0.42704
TATE 8F•�
(� NAt�
William M. Ranieri, P c # 42704
Job toss Truss Type
Dwg No 1132
728315 H1 Roof Special Girder 1 1
Job Reference(optional)
I Qty ply
American Builder's Supply,Sanford,FL 32771 - Run:7.520 s May B 2014 Prirrt 7520 s May 8 2014 M7ek Industries,Inc.Thu Ary 2815:29:10 2014 Page 2
I D:c8A3zpKbMf N UP?GwJa8Yk9zZj N-I u0?lW rl iIPkY88_ZCna PmoWd WAYIY88GI?pwy�Hzt
LOAD CASE(S) Standard
Uniform Loads(plf)
Vert:1-2=-60,2-3=-60,3-4=-60,4-5=-60,5-6=-60,6-7=-60,7-8=-60,8-9=-60,10-15=-20
Concentrated Loads(Ib)
Vert:3=71(B)7=71(B)16=31(B)17=31(B)18=45(B)19=18(B)20=18(B)21=45(B)
M.
'�LICENSE�� m
�
s No.42704 '-*"g zg
1 STATE OF
NA►.�
William M. Ranieri, P c # 42704
Job
cuss `Truss ype Dwg No 1671
728315 GX Scissor Structural 1 1
__ Job Reference(optional)
American Builder's Supply,Sanford,FL 32771 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MTek Industries,Inc.Thu Aug 28 15:29:09 2014 Page 1
I D:c8A3zpKbMfN U P?GwJa8Yk9zZ1[N-gisdfAggxSHMRZo?VGLsdEgzD9Gpt?_vc?SG Uyj Hzu
-1-4-0 1-6-0_ 5$11 9-M 136-6 17-10-0 19.4-0 20-8-0
4$11 310.6 3-10-6 4-3-11 1$-0 1-0-0
Scale=1:368
4x4= Dead Load DO. i
=1/4 n
5
6.00 F12 7x8 il—� 32 33
87x8
4
T
3x4 31 11 0 34
9V ` B EVA
2 g
1 1 8 I�N
14 1210 9
13 3.00 12
3x6 II 5xB— 5x8= 7x10
NA71J 1-6-0, 98-0 17-10.0 18 9019-4-0
tY7-tl 0-11% 8-2-0 8-2-0 o-11-0�0-711
Plate Offsets(X,Y)- [4:0-4-0,0-2-41.[6:0-4-0,0-2-4],[9:0-0-8,0-2-121.[14:0-M,0-1-8],117:0-1-10,0-1-01,127:0-1-10,0-1-01
LOADING(psf) SPACING- 2-0-0 CSI. DEFL in (loc) I/defl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.33 Vert(LL) -0.15 10-11 >999 240 MT20 244/190
TCDL 10.0 Lumber Increase 1.25 BC 0.72 Vert(TL) -0.41 10-11 >530 180
BCLL 0.0 ' Rep Stress Incr YES WB 0.53 Horz(TL) 0.10 9 n/a n/a
BCDL 10.0 Code FBC2010fTP12007 (Matrix-M) Weight:124 Ib FT=20%
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-1-14 oc purlins, except
BOT CHORD 2x4 SP No.2 end verticals.
WEBS 2x4 SP No.3'Except' BOT CHORD Rigid ceiling directly applied or 6-M oc bracing.
EV2:2x8 SP No.2 MiTek recommends that Stabilizers and required cross bracing
OTHERS 2x4 SP No.3 be installed during truss erection,in accordance with Stabilizer
Installation guide.
REACTIONS. (Ib/size) 9=826/04-0 (min.0-1-8),13=871/0-4-0 (min.0-1-8)
Max Horz 13=-135(LC 10)
Max Uplift9=-243(LC 12),13=-266(LC 12)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 3-31=-561/120,4-31=-491/136,4-32=-1246/314,5-32=-1186/328,5-33=-1186/315,
6-33=-1247/302,6-34=-804/225,7-34=-882/206,7-9=-864/323
BOT CHORD 11-12=-253/1223,10-11=-319/1304
WEBS 5-11=-159/855,6-10=-662/234,4-12=-915/352,3-13=-942/272,3-12=-80/618,
7-10=-43/656
NOTES- (10)
1)Unbalanced roof live loads have been considered for this design.
2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf;BCDL=4.2psf;h=15ft;B=45ft;L=24ft;eave=4ft;Cat.II;
Exp C;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)-1-4-0 to 1-8-0,Interior(1)1-8-0 to 9-8-0,Exterior(2)9-8-0 to 12-8-0
zone;cantilever left and right exposed;C-C for members and forces&MW FRS for reactions shown;Lumber DOL=1.60 plate grip
DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind(normal to the face),see Standard Industry
Gable End Details as applicable,or consult qualified building designer as per ANSI/TPI 1.
4)All plates are 2x4 MT20 unless otherwise indicated.
5)Gable studs spaced at 14-0 oc.
6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
8)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 243 Ib uplift at joint 9 and 266 Ib uplift at joint
13.
9)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
10)Segn:A0020111,Date:08/28/2014
■
LOAD CASE(S) Standard � `;••••••`•••.
LICENSE m
No.427Q4 :
STATE OF
0 Ft
; 4
William M. Ranieri, P c # 42704
0 russ �M=Dnop�itchGirldew
DNg No1 Ply
728315GAG 1 1
Job Reference(optional)
American Builder's Supply,Sanford,FL 32771 Run:7.520 s May 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc.Thu Aug 28 15:29:08 2014 Page 1
511-0
ID:c8A3zpKbMfNUP?GwJa8Yk9z4N-MVJESgp2A89OJr_cSn16KQhRUgre4Y?rhyGvk1 yj Hzv
55-11-0
2x4 11 Scale=1:20.2
2 Dead Load Defl.=1/8 in
6.00F1_2
T1
1
B1
"`111 7 8 3
HUS26 HUS26
2x4 I I
5x6=
5-11-0
Plate Offsets(X,Y)- [1:0-0-11,0-0-14) 511-0
LOADING(psf) SPACING- 2-0-0 CSI. DEFL, in (loc) I/defl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.63 Vert(LL) -0.10 3-6 >724 240 MT20 244/190
TCDL 10.0 Lumber Increase 1.25 BC 0.62 Vert(TL) -0.24 3-6 >292 180
BCLL 0.0 ' Rep Stress Incr NO WB 0.00 Horz(TL) 0.02 1 n/a n/a
BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight:28 Ib FT=20%
LUMBER- BRACING-
TOP CHORD 2x4 SP Not TOP CHORD Structural wood sheathing directly applied or 4-8-7 oc purlins, except
BOT CHORD 2x6 SP 240OF 2.0E end verticals.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection,in accordance with Stabilizer
Installation guide.
REACTIONS. (Ib/size) 1=942/0-6-0 (min.0-1-8),3=907/Mechanical
Max Horz 1=102(LC 21)
Max Upliftl=-204(LC 8),3=-249(LC 8)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 1-2=-1471/322
BOT CHORD 1-7=-739/2618
NOTES- (10)
1)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf;BCDL=4.2psf;h=15ft;B=45ft;L=24ft;eave=4ft;Cat.ll;
Exp C;Encl.,GCpi=0.18;MWFRS(directional);cantilever left and right exposed;Lumber DOL=1.60 plate grip DOL=1.60
2)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4)Refer to girder(s)for truss to truss connections.
5)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 204 Ib uplift at joint 1 and 249 Ib uplift at joint
3.
6)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
7)Use Simpson Strong-Tie HUS26(14-1 Od Girder,4-1Od Truss,Single Ply Girder)or equivalent spaced at 2-0-0 oc max.starting at
1-11-12 from the left end to 3-11-12 to connect truss(es)GA2(1 ply 2x4 SP)to front face of bottom chord.
8)Fill all nail holes where hanger is in contact with lumber.
9)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B).
10)Segn:A0020109,Date:08/28/2014
LOAD CASE(S) Standard
1)Dead+Roof Live(balanced):Lumber Increase=1.25,Plate Increase=1.25
Uniform Loads(plf)
Vert:1-2=-60,3-4=-20
Concentrated Loads(lb) �� M■
Vert:7=-694(F)8=-694(F) �••.••+••..'
'LICENSE•:r� m
fe N0.42704
STATE OF 4
%'.".o R1o,.P••
sSNAI�
William M. Ranieri, P c t42704
Job Hiss Truss Type
Dwg No 095
728315 GA2X Common Girder 1 1
Fference(optional)
American Builder's Supply,Sanford,FL 32771 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MTek Industries,Inc. Thu Aug 2815:29:08 2014 Page 1
ID:c8A3zpKbMfN U P7GwJa8Yk9zZj)N-MVJ ESgp2A89OJr__cSnl6KQhVAquT4XHrtiyGvkl yjHzv
1 4 0 4-5-14 8-11-8 13-5-2 17-11-019-3-0
1 4 0 4-5-14 4-55-10 4-5-10 4-5-14 14-0
40= Scale=1:34.9
5
6.00 12
NAILED 6NAILED
4
Special Ni SpeCW
3x4 i 24 25 3x4
3 qq W4 ZKL W5 ET V116 W7 7
2 •q 8
9 I�B1 g2
26 27 28 29 10 30 31 32 33
3x6 II special NAILED NAILED NAILED 5x8= NAILED NAILED Special
34 11
NAILED
8-11-8 17-11-0
8-11-8 8-11-8
Plate Offsets(X,Y)— [2:0-0-1,0-1-5],[8:0-3-1,0-15],[10:0-4-0,0 -0] [13:0-1-12,0-0-121,113:0-1-12,0-0-121
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.33 Vert(LL) -0-0610-18 >999 240 MT20 244/190
TCDL 10.0 Lumber Increase 1.25 BC 0.44 Vert(TL) -0-1310-18 >999 180
BCLL 0.0 ' Rep Stress Incr NO WB 0.11 Horz(TL) 0.03 8 n/a n/a
BCDL 10.0 Code FBC2010fTP12007 (Matrix-M) Weight:107 Ib FT=20%
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 1040-0 oc bracing.
WEBS 2x4 SP No.3 MiTek recommends that Stabilizers and required cross bracing
SLIDER Left 2x4 SP No.3 1-6-0,Right 2x4 SP No.3 1-6-0 be installed during truss erection,in accordance with Stabilizer
REACTIONS. (Ib/size) 2=597/0-6-0 (min.0-1-8),8=598/0-6-0 (min.0-1-8) Installation guide.
Max Horz 2=-125(LC 6)
Max Uplift2=-281(LC 8),8=-281(LC 8)
Max Grav2=629(LC 36),8=630(LC 37)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 2-3=-487/82,3-24=-838/349,4-24=-844/373,4-5=-704/319,5-6=-704/319,6-25=-842/373,
7-25=-838/349,7-8=-486/84
BOT CHORD 2-26=-240/813,26-27=-240/813,27-28=-240/813,28-29=-240/813,10-29=-240/813,
10-30=-239/738,30-31=-239/738,31-32=-239/738,32-33=-239/738,8-33=-239/738
WEBS 510=-151/340
NOTES- (11)
1)Unbalanced roof live loads have been considered for this design.
2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf;BCDL=4.2psf;h=15ft;B=45ft;L=24ft;eave=4ft;Cat.II;
Exp C;Encl.,GCpi=0.18;MWFRS(directional);cantilever left and right exposed;Lumber DOL=1.60 plate grip DOL=1.60
3)All plates are 2x4 MT20 unless otherwise indicated.
4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 281 Ib uplift at joint 2 and 281 Ib uplift at joint
8.
7)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
8)"NAILED"indicates 3-10d(0.148"x3")or 3-12d(0.148"x3.25")toe-nails.For more details refer to MiTek's ST-TOENAIL Detail.
9)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)122 Ib down and 158 Ib up at 2-0-0,
and 122 Ib down and 158 Ib up at 1510-3 on top chord,and 42 Ib down and 75 Ib up at 2-0-0,and 42 Ib down and 75 Ib up at 15-10-3
on bottom chord. The design/selection of such connection device(s)is the responsibility of others.
10)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B).
11)Segn:AO020107,Date:08/28/2014 ■
LOAD CASE(S) Standard � .••••...^rye/'
1)Dead+Roof Live(balanced):Lumber Increase=1.25,Plate Increase=1.25 ,x• •'.•"'•III w
LICEfVSE
Uniform Loads(plf) 5-g
Vert:1-5=-60,5-9=-60,16-20=-20 :r
s No.42704
Continued on page 2 ••1
STATE aF
d F119646 '�v
William M. Ranieri, P c # 42704
NSS I NSS I ypB
' Dwg NO 095
Qty ply
728315 GA1 COMMON 1 1
Job Reference(optional)
American Buiklees Supply,Sanford,FL 32771 Run:7.520 s May B 2014 Print:7.520 s May 8 2014 MTek Industries,Inc.Thu Aug 2815:29:06 2014 Page 1
ID:c8A3zpKbMfNUP?GwJa8Yk9zZjN-Q7BU19ooeXvl3XrDKMieF?cB308bcchYDenof9yfHzx
1 4 0 4-5-14 8-11-8 13-52 17-11-0
1�0 4-514 4-510 4-510 4-514
Scale-1:32.4
4x4— Dead Load Defl.=1/8 in
5
6.00 12 79 20
2x4 2x4
4 e
1 21
3x4 G 18 7
3x4 c
3
8
2 q
B1 82 Id
9 M
3x8 I I 5A= 3x6 I I
, 8-11-8 17-11-0 I
8-11-8 B-11-8
Plate Offsets(X,Y)— [2:0-4-1,Edge],[8:0-3-8,Edge],[9:0-4-0,0-3-0]
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) /defl Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.24 Vert(LL) -0.08 9-12 >999 240 MT20 244/190
TCDL 10.0 Lumber Increase 1.25 BC 0.66 Vert(TL) -0.22 9-12 >988 180
BCLL 0.0 ' Rep Stress Incr YES WB 0.18 Horz(TL) 0.03 8 n/a n/a
BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight:85 Ib FT=20%
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-6-5 oc purlins.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-"oc bracing.
WEBS 2x4 SP No.3 MiTek recommends that Stabilizers and required cross bracing
SLIDER Left 2x4 SP No.3 1-6-0,Right 2x4 SP No.3 1-6-0 be installed during truss erection,in accordance with Stabilizer
Installation guide.
REACTIONS. (Ib/size) 8=714/0-6-0 (min.0-1-8),2=800/0-6-0 (min.0-1-8)
Max Horz2=122(LC 11)
Max Uplift8=-164(LC 12),2=-230(LC 12)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown.
TOP CHORD 2-3=-756/0,3-18=-1073/356,4-18=-997/368,4-19=-839/274,5-19=-777/285,
5-20=-777/300,6-20=-840/289,6-21=-1006/386,7-21=-1082/373,7-8=-778/61
BOT CHORD 2-9=-273/922,8-9=-274/935
WEBS 5-9=-93/473,6-9=-298/184,4-9=-284/178
NOTES- (7)
1)Unbalanced roof live loads have been considered for this design.
2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf;BCDL=4.2psf;h=15ft;B=45ft;L=24ft;eave=4ft;Cat.11,
Exp C;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)-1-4-0to 1-8-0,Interior(1)1-8-0 to 8-11-8,Exterior(2)8-11-8 to
11-11-8 zone;cantilever left and right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate
grip DOL=1.60
3)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4)'This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 164 Ib uplift at joint 8 and 230 Ib uplift at joint
2.
6)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
7)Segn:A0020105,Date:08/28/2014
LOAD CASE(S) Standard
LICENSE�%. m
No.42704 ?
s STATE OF
a,!► .�0 R1900
William M. Ranieri, P c # 42704
Job Truss cuss ype
D++g No 093
728315 G2 Common 1 1
Job Reference(optional)
American Builders Supply,Sanford,FL 32771 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MTek Industries,Inc. Thu Aug 2815:29:05 2014 Page 1
ID:c8A3zpKbMfNUP?GwJa8Yk9zZjjN-xwd6gpnAtDnRRNG1 mfBPin4OEcnMt82P_1 E7jyjHzy
5-5-9 9-8-013-10-8 19-4-0 20-8-0
5-5-9 4-2-8 4-2-8 5-5-9 1 14-0
4X4= Scale=1:34.6
Dead Load Defl.=3/16 in
4
6.00 F12
2x4 19 20 2x4 i
3 5
18
3x4 21 3x4
2 6
1 7
1
81 8
82 d
9
3x8 I I f;�= 3x8 11
9-8-0 194-0
9-8-0 Sao
Plate Offsets QX Y)— [1:0-3-8,Edge],p:0-4-1,Edge] [9:0-4-0,0-3-0]
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (foe) I/deft Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.25 Vert(LL) -0.11 9-12 >999 240 MT20 244/190
TCDL 10.0 Lumber Increase 1.25 BC 0.78 Vert(TL) -0.30 9-12 >765 180
BCLL 0.0 ' Rep Stress Incr YES WB 0.21 Horz(TL) 0.03 7 n/a n/a
BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:90 Ib FT=20%
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-4-3 oc purlins.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-M oc bracing.
WEBS 2x4 SP No.3 MiTek recommends that Stabilizers and required cross bracing
SLIDER Left 2x4 SP No.3 1-6-0,Right 2x4 SP No.3 1-6-0 be installed during truss erection,in accordance with Stabilizer
REACTIONS. (Ib/size) 1=771/Mechanical,7=856/0-6-0 (min.0-1-8) Installation guide.
Max Hoa 1=-131(LC 10)
Max Upliftl=-1 78(LC 12),7=-243(LC 12)
FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 1-2=-856/34,2-18=-1109/390,3-18=-1107/399,3-19=-905/311,4-19=-841/326,
4-20=-841/311,5-20=-904/300,5-21=-1099/383,6-21=-1151/367,6-7=-836/0
BOT CHORD 1-9=-255/992,7-9=-257/983
WEBS 4-9=-134/539,5-9=-303/189,3-9=-313/194
NOTES- (8)
1)Unbalanced roof live loads have been considered for this design.
2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf;BCDL=42psf;h=15ft;B=45ft;L=24ft;eave=4ft;Cat.ll;
Exp C;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)0-0-0 to 3-0-0,Interior(1)3-0-0 to 9-8-0,Exterior(2)9-8-0 to 12-8-0
zone;cantilever left and right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip
DOL=1.60
3)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5)Refer to girder(s)for truss to truss connections.
6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 178 Ib uplift at joint 1 and 243 Ib uplift at joint
7.
7)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
8)Segn:AO020103,Date:08/28/2014
LOAD CASE(S) Standard
ks GENSE••• m
No.42704
STATE OF
0 F119
William M. Ranieri, P c # 42704
Job Truss Fuss ype
_7
OvA
728315 G Sdssor 2 1
0r+9 No
Job Reference o tional
American Builder's Supply,Sanford,FL 32771 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MTek Industries,Inc.Thu Aug 28 15:29:04 2014 Pa 1
ID:c8A3zpKbMfNU P?GwJa8Yk9zzjiN-Tk3kcTmX6vfbgDhgDygA9aXnOCS98crFmKlhb(!yrzz
1-0 0 1-0 0 5 9 11 9 8 0 13-0-6 17-10-0 19-0-0 20-8-0
1-0-0 1�-0 4-3-11 3-10 3-10-0 4-311
Scale=1:35.7
4x4= Dead Load DO.=1/4 in
5
6.00 12 4x6 4 o 18 19
64x6
NJ
2x4 11 13 20 2x4 11
3 17 7
54
2 1 B N
1 B4 9 Id
16 15 14 &DO 12 1211 10
3x6 11 5x6= 5x6= 3x6 11
p 7-0 1�i0 9-8-0 17-10-0 118-9-0194-0
0-7-0 0-11-0 8-2-0 B-2-0 0 11-0 7
Plate Offsets(X,Y)- [10:0-0-8,0-1-81,[16:0-3-8,0-1-81
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.47 Vert(LL) -0.16 13-14 >999 240 MT20 244/190
TCDL 10.0 Lumber Increase 1.25 BC 0.72 Vert(TL) -0.44 13-14 >489 180
BCLL 0.0 ' Rep Stress Incr YES WS 0.52 Horz(TL) 0.09 11 n/a n/a
BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:101 Ib FT=20%
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-4-0 oc purlins, except
BOT CHORD 2x4 SP No.2 end verticals.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection,in accordance with Stabilizer
REACTIONS. (Ib/size) 15=850/0-4-0 (min.0-1-8),11=850/0-4-0 (min.0-1-8) Installation guide.
Max Horz 15=-134(LC 10)
Max Upliftl5=-260(LC 12),11=-244(LC 12)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 2-3=-522/97,3-17=-495/123,4-17=-483/139,4-18=-1183/294,5-18=-1124/308,
5-19=-1124/294,6-19=-1183/280,6-20=-483/140,7-20=-495/123,7-8=-522/97,
2-16=-460/170,8-10=-460/170
BOT CHORD 15-16=48/398,14-15=-27/472,13-14=-231/1172,12-13=-273/1169,11-12=-48/398,
10-11=-48/398
WEBS 5-13=-136/795,6-12=-903/311,4-14=-903/327
NOTES- (7)
1)Unbalanced roof live loads have been considered for this design.
2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf;BCDL=4.2psf;h=15ft;B=45ft;L=24ft;eave=4ft;Cat.ll;
Exp C;Encl.,GCpi=0.18;MWFRS(directional)and C-C Extedor(2)-1-4-0 to 1-8-0,Interior(1)1-8-0 to 9-8-0,Exterior(2)9-8-0 to 12-8-0
zone;cantilever left and right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip
DOL=1.60
3)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 260 Ib uplift at joint 15 and 244 Ib uplift at
joint 11.
6)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
7)Segn:AO020104,Date:08/28/2014
LOAD CASE(S) Standard
��. LICENSE••• m
NON42704 i
STATE 8F
ass.........����
�NAI�
William M. Ranieri, P c # 42704
Job cuss Iruss type
' favg Na O5�
728315 EJK1 Jack-0pm Qty ply 12 1
Job Reference o tional
Mierican Buiklers Supply,Sanford,FL 32771 Run:7.520 s Mayy 8 2014 Pmt:7.520 s May 8 2014 M7ek Industries,Inc.Thu Aug 2815:29:03 2014 Page 1
1 4 0 ID 6c�A3zpF01MfNUP?GwJa8Yk9zZg?YVLP71vLcXkC46efE9xdM_eApEiPHm6xhY84gyjl_
1�0 4-64
Scale=1:17.2
3
6.00 F12
6 N
T1 N
N
2
EVII
1 a1
4
5 3x6 11
4-6-4
4-6-4
Plate Offsets Qx Y)- [5:0-3-8.0-1-8] --
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in floc) I/defl Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.35 Vert(LL) 0.03 4-5 >999 240 MT20 244/190
TCDL 10.0 Lumber Increase 1.25 BC 0.22 Vert(TL) -0.04 4-5 >999 180
BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.02 3 n/a n/a
BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:17 Ib FT=20%
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-6-4 oc purlins, except
BOT CHORD 2x4 SP Not end verticals.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection,in accordance with Stabilizer
Installation uide.
REACTIONS. (Ib/size) 5=277/04-0 (min.0-1-8),3=111/Mechanical,4=47/Mechanical
Max Horz5=116(LC 12)
Max Uplift5=-92(LC 12),3=-64(LC 12)
Max Grav5=277(LC 1),3=115(LC 17),4=80(LC 3)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
NOTES- (7)
1)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf;BCDL=4.2psf;h=15ft;B=45ft;L=24ft;eave=4ft;Cat.ll;
Exp C;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)-1-4-0 to 1-8-0,Interior(1)1-8-0 to 4-5-8 zone;cantilever left and right
exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60
2)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4)Refer to girder(s)for truss to truss connections.
5)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 92 Ib uplift at joint 5 and 64 Ib uplift at joint 3.
6)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
7)Segn:AO020069,Date:08/28/2014
LOAD CASE(S) Standard
M.
\ . LICENSE'•••���
Jf No.42704
%* TATE OF
%04 0 F110
William M. Ranieri, P c # 42704
Job cuss Hiss ype
728315 EJ28 Jack-0pen 4 1
a+9 No 057
Job Referen�fopfioaalj
American Builder's Supply,Sanford,FL 32771 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MTek Industries,Inc. Thu Aug 2815:29:01 2014 Page 1
I D:cBA3zpKbMfN U P?GwJa8Yk9zZjj N-39 N b_Rkfq_H OzmyFXp7TYxvLO?aexNGp4 N31?xyj I_0
Scale=1:13.6
3
6.00 F12 6
N
2 T1 0)N
C6
1
B1
4
5
3x8 I I
2-8-8
2-8-8
Plate Offsets(X,Y)— [5:0-4-8,0-1-8)
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.20 Vert(LL) -0.00 4-5 >999 240 MT20 244/190
TCDL 10.0 Lumber Increase 1.25 BC 0.07 Vert(TL) -0.00 4-5 >999 180
BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 3 n/a n/a
BCDL 10.0 Code FBC2010ITP12007 (Matrix-M) Weight:11 Ib FT=20%
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 2-8-8 oc puriins, except
BOT CHORD 2x4 SP No.2 end verticals.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection,in accordance with Stabilizer
REACTIONS. (Ib/size) 5=215/0-6-0 (min.0-1-8),3=54/Mechanical,4=20/Mechanical Installation guide.
Max Horz 5=84(LC 12)
Max Uplift5=-86(LC 12),3=-33(LC 12)
Max Grav5=215(LC 1),3=58(LC 17),4=45(LC 3)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
NOTES- (7)
1)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf;BCDL=4.2psf;h=15ft;B=45ft;L=24ft;eave=4ft;Cat.11;
Exp C;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)-1-4-0 to 1-8-0,Interior(1)1-8-0 to 2-7-12 zone;cantilever left and
right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber D0L=1.60 plate grip DOL=1.60
2)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4)Refer to girder(s)for truss to truss connections.
5)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 86 Ib uplift at joint 5 and 33 Ib uplift at joint 3.
6)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
7)Segn:AO020067,Date:08/28/2014
LOAD CASE(S) Standard
MAO
44,44
LICENSE'•• m
No.42704
i STATE DF
O Rlp�''�ti
ass 440..4. .- �'
William M. Ranieri, P c # 42704
Job cussnrss ype
Dwg No 056
728315 EJ7T Jack-Open 4 1
Job Refere�(opfional)
American Builders Supply,Sanford,FL 32771 Run:7.520 s Ma 82014 Print:7.520 s Ma 6 2014 MTek Industries,Inc.Thu Aug 28 15:29:00 2014 Page 1
1�0 2�0 ID:c8A9zp 4)-0 ?GwJa8Yk9zZjjN bzgDm5j13h99LcN3_6bE?kM7nb7yCwOgIKUTVyil_1
1�0 2�0 4-8-0
4 Scale:112=1'
Dead Load Defl.=1/16 in
6.00 12
13
T1
12
3
2 B3
6 2x4 I I �
1 B1 �d
z =
7
8 2x4 11
3x6 11
2�0 7-0-0
2�-0 4-&0
Plate Offsets [3:0-1-14,0-0-8],[8:0-0-8,0-1-8]
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.42 Vert(LL) 0.07 5-6 >999 240 MT20 244/190
TCDL 10.0 Lumber Increase 1.25 BC 0.54 Vert(TL) -0.13 5-6 >646 180
BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) 0.03 5 n/a n/a
BCDL 10.0 Code FBC2010/T1312007 (Matrix-M) Weight:28 Ib FT=201/6
LUMBER- _ BRACING-
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-3-12 oc purlins, except
BOT CHORD 2x4 SP No.2*Except* end verticals.
B2:2x4 SP No-3 BOT CHORD Rigid ceiling directly applied or 6-M oc bracing.
WEBS 2x4 SP No.3 MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection,in accordance with Stabilizer
Installation uide.
REACTIONS. (Ib/size) 8=462/0-6-0 (min.0-1-8),4=142/Mechanical,5=58/Mechanical
Max Horz8=160(LC 12)
Max Uplift8=-1 1 O(LC 12),4=-81(LC 12)
Max Grav8=462(LC 1),4=146(LC 17),5=97(LC 3)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown.
TOP CHORD 2-8=-433/220,3-12=-1180/669
BOT CHORD 3-6=-1022/1588
NOTES- (7)
1)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf;BCDL=4.2psf;h=15ft;B=45ft;L=24ft;eave=oft;Cat.11;
Exp C;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)-14-0 to 1-8-0,Interior(1)1-8-0 to 6-11-4 zone;cantilever left and
right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60
2)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4)Refer to girder(s)for truss to truss connections.
5)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 110 Ib uplift at joint 8 and 81 Ib uplift at joint
4.
6)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
7)Segn:AO020066,Date:08/28/2014
LOAD CASE(S) Standard
� . M.
LICENSE'-*
No.42704
s STATE OF
William M. Ranieri, P c # 42704
ru russ ype
Dwg No 059
728315 EJ7
Jack-Open 4 1
Job Reference o tional
American Builders Supply,Sanford,FL 32771 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 M7ek Industries,Inc. Thu Aug 28 15:28:59 2014 Page 1
ID:c8A3zpKbMflJUP?GwJa8Yk9zZjjN-7mGrZliPI N1 liSotQO4?SWqu6BoATTmWc3awx3yjl_2
1 4 0 7-0-0
1 0 7-0-0 -
3 Scale:1/2'=1'
Dead Load Defl.=3/16 in
6.00 12
7 N
T1 v
cA
6
2
1
1
131
5 3x8 11 4
7-0-0 {
7-0-0
Plate Offsets(X,Y)— [5:0-4-0,0-04)
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.67 Vert(LL) 0.16 4-5 >519 240 MT20 244/190
TCDL 10.0 Lumber Increase 1.25 BC 0.51 Vert(TL) -0.26 4-5 >305 180
BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) 0.07 3 n/a n/a
BCDL 10.0 Code FBC2010lTPI2007 (Matrix-M) Weight:25 Ib FT=20%
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
BOT CHORD 2x4 SP No.2 end verticals.
WEBS 2x6 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection,in accordance with Stabilizer
Installation guide.
REACTIONS. (Ib/size) 5=373/0-6-0 (min.0-1-8),3=178/Mechanical,4=80/Mechanical
Max Horz5=161(LC 12)
Max Uplift5=-104(LC 12),3=-102(LC 12)
Max Grav5=373(LC 1),3=183(LC 17),4=125(LC 3)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 2-5=-318/245
NOTES- (7)
1)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf;BCDL=4.2psf;h=15ft;B=45ft;L=24ft;eave=4ft;Cat.11;
Exp C;Encl.,GCpi=0.18;MWFRS(directional)and C-C Extedor(2)-1-4-0 to 1-8-0,Interior(1)1-8-0 to 6-11-4 zone;cantilever left and
right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60
2)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4)Refer to girder(s)for truss to truss connections.
5)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 104 Ib uplift at joint 5 and 102 Ib uplift at joint
3.
6)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
7)Segn:A0020063,Date:08/28/2014
LOAD CASE(S) Standard
; LICENSE = s
Of No. 2704
STA64
`�rTE �F
ass.........-�.�'
�7NA1.�
William M. Ranieri, P c # 42704
Russ �7, :
728315 EJ4F 2 7 1
a9 No OEM
Job Reference o tional
American Builders Supply,Sanford,FL 32771 Run:7.520 s May 8 2014 Print:7.520 s May.8 2014 MiTek Industries,Inc.Thu Aug 28 15:28:58 2014 Page 1
ID:c8A3zpKbMfNUP7GwJa8Yk9zZbN-eaiSMOhnX3vR6l DhshZmwJHrmYhkOWNNPrNOcyjl_3
-141-0 40-0
1�0 4-0-0
Scale=1:10.2
3
3.00 F12
9
0
2 T1
8 n
1
Bt
4
3X4-
F - - --- _ 4-0-0 ----
4-0-0
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.18 Vert(LL) 0.02 4-7 >999 240 MT20 244/190
TCDL 10.0 Lumber Increase 1.25 BC 0.15 Vert(TL) -0.03 4-7 >999 180
BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) 0.01 3 n/a n/a
BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:14 Ib FT=20%
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection,in accordance with Stabilizer
Installation uide.
REACTIONS. (Ib/size) 3=99/Mechanical,2=251/0-6-0 (min.0-1-8),4=45/Mechanical
Max Horz 2=53(LC 12)
Max Uplift3=-42(LC 12),2=-102(LC 12)
Max Grav3=99(LC 1),2=251(LC 1),4=71(LC 3)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
NOTES- (7)
1)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf;BCDL=4.2psf;h=15ft;B=45ft;L=24ft;eave=4ft;Cat.ll;
Exp C;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)-1-4-0 to 1-8-0,Interior(1)1-8-Oto 3-11-4 zone;cantilever left and
right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60
2)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3)'This truss has been designed fora live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4)Refer to girder(s)for truss to truss connections.
5)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 42 Ib uplift at joint 3 and 102 Ib uplift at joint
2.
6)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
7)Segn:A0020061,Date:08/28/2014
LOAD CASE(S) Standard
• LICENSE": m
No.42704
STATE 4F
William M. Ranieri, P c # 42704
Hiss russ ype
Dwg No 049
728315
E.3 Jadc0
pen 4 1
City pl� Job Reference(optional)
American Builders Soppy,Sanford,FL 32771 Run:7.520 s May 8 2014 Print:7.520 s May.8 2014 MTek Industries,Inc.Thu Aug 2815:28582014 Page 1
ID:c8A3z-0 MfNUP?GwJa8Yk9zZjlN-eaiSMQhnX3vR61DhshZmwJHrHoZtkOWNNPrNONI_3
-1-4-0 3.0.0
1 0 3-0..0
Scale=1:13.5
3
6.00 12 6
N
T1 '�N
2
El/1
1 B1
4
5
3x6 I I
- -- 3-0-0 -
Plate Offsets QX Y)- [5:03 3-0-0-8,0-1-81 -
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.16 Vert(LL) -0.00 4-5 >999 240 MT20 244/190
TCDL 10.0 Lumber Increase 1.25 BC 0.07 Vert(TL) -0.01 4-5 >999 180
BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) 0.00 3 n/a n/a
BCDL 10.0 Code FBC2010(rP12007 (Matrix-M) Weight:12 Ib FT=20%
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-0-0 oc purlins, except
BOT CHORD 2x4 SP No.2 end verticals.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection,in accordance with Stabilizer
Installation uide.
REACTIONS. (Ib/size) 5=224/0-6-0 (min.0-1-8),3=64/Mechanical,4=24/Mechanical
Max Horz 5=89(LC 12)
Max Uplifts=-91(LC 12),3=-37(LC 12)
Max Grav5=224(LC 1),3=68(LC 17),4=50(LC 3)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown.
NOTES- (7)
1)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf;BCDL=4.2psf;h=15ft;B=45ft;L=24ft;eave=4ft;Cat.II;
Exp C;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)-1-4-0 to 1-8-0,Interior(1)1-8-0 to 2-11-4 zone;cantilever left and
right exposed;C-C for members and forces 8 MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60
2)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3)`This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4)Refer to girder(s)for truss to truss connections.
5)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 91 Ib uplift at joint 5 and 37 Ib uplift at joint 3.
6)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
7)Segn:AO020059,Date:08/28/2014
LOAD CASE(S) Standard
LICENSE•:*���
fe N0.42704 i
STATE OF
William M. Ranieri, P c # 42704
JJob Truss Truss Type Qty ply
728315 EJ1H Jack-Open 2 1 ' DvrgHo049
Job Reference o tional
American Builders Supply,Sanford,FL 32771 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 Mi7ek Industries,Inc. Thu Aug 2815:28:56 2014 Page 1
ID:c8A3zpKbMfNUP?GwJa8YkWz N-iCaixkgW?SFjs?411GXIruCVO_u?G614w5MGKkyjI_5
-1-4-0 1-0-0
1-4-0 1-0-0
Scale=1:9.4
3
6.00 F12
2
T1 1
d
1
B1
RE 4
5
3x8 11
1-0-0
Plate Offsets(X,Y)— [5:0-4-8,0-1-8] 1-0-0
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.19 Vert(LL) 0.00 5 >999 240 MT20 244/190
TCDL 10.0 Lumber Increase 1.25 BC 0.03 Vert(TL) 0.00 5 >999 180
BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 3 n/a n/a
BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight:6 Ib FT=20%
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc purlins, except
BOT CHORD 2x4 SP No.2 end verticals.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection,in accordance with Stabilizer
Installation guide.
REACTIONS. (Ib/size) 5=200/0-6-0 (min.0-1-8),4=-11/Mechanical,3=-33/Mechanical
Max Horz5=55(LC 12)
Max Uplift5=-110(LC 12),4=-11(LC 1),3=-33(LC 1)
Max Grav5=200(LC 1),4=10(LC 3),3=24(LC 12)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
NOTES- (7)
1)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf;BCDL=4.2psf;h=15ft;B=45ft;L=24ft;eave=4ft;Cat.II;
Exp C;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)zone;cantilever left and right exposed;C-C for members and forces
&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60
2)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4)Refer to girder(s)for truss to truss connections.
5)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 110 Ib uplift at joint 5,11 Ib uplift at joint 4
and 33 Ib uplift at joint 3-
6)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
7)Segn:A0020057,Date:08/28/2014
LOAD CASE(S) Standard
��1 MJA.Zn� .
' LICENSE••;
- '
s No.4Z704
STATE OF
William M. Ranieri, P c # 42704
Truss russype Qty
17�
' Dvg No 040
728315 DG Common Girder 1 1
_ _ Job Reference(optional)
American Builder's Supply,Sanford,FL 32771 - Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 M7ek Industries,Inc.Thu Aug2815:28:56 2014 Page 1
ID:c8A3zpKbMfNUP?GwJa8Yk9z7 jN-iCabckgW?Sfjs?411GXINCILJ5Gvw4w5MGKkyjI_5
7-7-8 1.4-11-8 19-10-11 26-9-6 29-11-0
1 4 0 7-7-8 7--0 411-3 6-10 11 31-10
4x6 11 Scale=1:54.4
Dead Load Defl.=5/16 in
6.00 12 6
3x4 2x4 11
7 3x4
2x4\\ 5 8
4
5x6
9
3x4
3
2
1 1 id
62
14 13 22 23 12 11
56 11 4x4 7x10 MT20H= 3x10 11 7x8=
3x4=
HHUS26-2
10-0-5 19-10-11 1 26-9-6 29-11-0
10-0-5 9-10-6 6-10-11 31-10
Plate Offsets(X,Y)— [2:0-3-9,0-0-1],[10:0-M 0-3-1] [12:0-4-12 0-3-4]
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in floc) I/defl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.96 Vert(LL) -0.33 12-14 >999 240 MT20 244/190
TCDL 10.0 Lumber Increase 1.25 BC 0.73 Vert(TL) -0.67 12-14 >534 180 MT20H 187/143
BCLL 0.0 ' Rep Stress Incr NO WB 0.84 Horz(TL) 0.09 10 n/a n/a
BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight:161 Ib FT=20%
LUMBER- BRACING-
TOP CHORD 2x4 SP M 30'Except' TOP CHORD Structural wood sheathing directly applied.
T4:2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 8-11-14 oc bracing.
BOT CHORD 2x4 SP M 30*Except* WEBS 1 Row at midpt 9-12
132:2x6 SP 2400F 2.0E MiTek recommends that Stabilizers and required cross bracing
WEBS 2x4 SP No-3 be installed during truss erection,in accordance with Stabilizer
SLIDER Left 2x4 SP No.3 1-6-0 Installation guide.
REACTIONS. (Ib/size) 2=1531/0-6-0 (min.0-1-13),10=3352/0-6-0 (min.0-2-12)
Max Horz 2=203(LC 7)
Max Uplift2=-405(LC 8),10=-829(LC 8)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 2-3=-1203/2,3-4=-2477/621,4-5=-2275/605,5-6=-2169/630,6-7=-2911/850,
7-8=-2739/722,8-9=-2906/708,9-10=-5838/1463
BOT CHORD 2-14=-471/2150,13-14=-274/1625,13-22=-274/1625,22-23=-274/1625,12-23=-274/1625,
11-12=-1283/5178,10-11=-1283/5178
WEBS 4-14=420/257,6-14=-169/744,6-12=-464/1705,7-12=-421/234,9-12=-2796/794,
9-11=-544/1918
NOTES- (11)
1)Unbalanced roof live loads have been considered for this design.
2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf;BCDL=4.2psf;h=15ft;B=45ft;L=30ft;eave=4ft;Cat.ll;
Exp C;Encl.,GCpi=0.18;MWFRS(directional);cantilever left and right exposed;Lumber DOL=1.60 plate grip DOL=1.60
3)All plates are MT20 plates unless otherwise indicated.
4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members,with BCDL=10.Opsf.
6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 405 Ib uplift at joint 2 and 829 Ib uplift at joint
10.
7)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
8)Use Simpson Strong-Tie HHUS26-2(14-10d Girder,6-10d Truss,Single Ply Girder)or equivalent at 26-6-9 from the left end to connect
truss(es)D-FG(2 ply 2x6 SP)to back face of bottom chord.
9)Fill all nail holes where hanger is in contact with lumber.
10)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). ■
11)Segn:A0020056,Date:08/28/2014
LOADCASE(S) Standard
1)Dead+Roof Live(balanced):Lumber Increase=1.25,Plate Increase=1.25LICENSE '•
Uniform Loads(plo
Vert:1-6=-60,6-10=-60,1319=-20
N0.42704
Continued on page 2 S STAT QF •
i
William M. Ranieri, P c # 42704
Truss I ruse I ype City Ply
' Dr+9 No 04L
728315 DA14 Hip 1 1
Job Reference(optional)
American Builders Supply,Sanford,FL 32771 Run:7.520 5 Mey 8 2014 Print 7.520 s May 8 2014 MiTek Industries,Inc.Thu Aug 28 15:28:55 2014 Page 1
ID:c8A3zpKbMfNUP?GwJa8Yk9zZiN-E?OKjOfuE8XsFrV6BZ03kjfCjaKCXabwhRcjolyi I_6
1�-0 7-7-8 13-7-0 16 -0 21-2-12 26 5 0
1�-0 7-7-8 5 11$ 2-9 0 4 70 12 5-2-4
Scale=1:46.9
6.00 72
5x6= 4x4 Dead Load Defl.=7116 in
=
6 7
3x4
19 3x4
2x4\\ 5 8
4
20
1 V4 20 11
9
3x4
78
3
13 2112 22 11
3x4- 10
3x8 I I 3Xs— 3x5—
10-0-5 16-40 21-2-12 26-5-0
10-0-5 6.3-11 4-10-12 5 2�
Plate Offsets(XY)- [2:0-4-1,Edge].[6:0-3-0,0-2-01 - —
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.70 Vert(LL) -0.2910-11 >999 240 MT20 244/190
TCDL 10.0 Lumber Increase 1.25 BC 0.90 Vert(TL) -0.7410-11 >428 180
BCLL 0.0 ' Rep Stress Incr YES WB 0.33 Horz(TL) 0.06 10 n/a n/a
BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight:149 Ib FT=20%
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-2-12 oc purlins, except
BOT CHORD 2x4 SP No.2 end verticals.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 811-12 oc bracing.
SLIDER Left 2x4 SPNo.31-6-0 WEBS 1Raw atmidpt 8-10
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection,in accordance with Stabilizer
Installation guide.
REACTIONS. (Ib/size) 2=1133/0-6-0 (min.0-1-8),10=1049/Mechanical
Max Horz 2=159(LC 11)
Max Uplift2=-304(LC 12),10=-246(LC 12)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 2-3=-1059/0,3-18=-1644/522,4-18=-1565/546,4-5=-1442/528,5-6=-1349/549,
6-7=-933/430,7-19=-1039/446,8-19=-1114/430
BOT CHORD 2-13=-480/1448,13-21=-264/986,12-21=-264/986,12-22=-264/986,11-22=-264/986,
10-11=-301/91 1
WEBS 4-13=-393/262,6-13=-182/585,7-11=-105/303,8-10=-1150/417
NOTES- (9)
1)Unbalanced roof live loads have been considered for this design.
2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf;BCDL=4.2psf;h=15ft;B=45ft;L=26ft;eave=4ft;Cat.ll;
Exp C;Encl.,GCpi=0.18;MWFRS(directional)and C-C Extedor(2)-1-4-0 to 1-8-0,Interior(1)1-8-0 to 13-7-0,Exterior(2)13-7-0 to 16-4-0
,Interior(1)20-6-15 to 26-3-4 zone;cantilever left and right exposed;C-C for members and forces&MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3)Provide adequate drainage to prevent water ponding.
4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members,with BCDL=10.Opsf.
6)Refer to girder(s)for truss to truss connections.
7)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 304 Ib uplift at joint 2 and 246 Ib uplift at joint
10.
8)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
9)Segn:AO020054,Date:08/28/2014
LOAD CASE(S) StandardA �■
zs'o' ICENS.E••;� m
N0.42704
STATE OF
William M. Ranieri, P c # 42704
Job I cuss Iruss type Qty ply
Dwg No 042
728315 DA10 Hip 1
TlJob
Reference(optional)
American Builders Supply,Sanford,FL 32771 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 M7ek Industries,Inc.Thu Augg 28 15:28:53 2014 Pagel
ID:c8A3zpKb=6P?GwJa8Yk9zZbN-ldvZl ieeiXGB?XLj38zaDFavMnhg3f4eE77cjpyj I_8
14-0 5-6-11 9-7-0 14-11-8 20�-0 26-5-0
14-0 5-6-11 4-0-5 54-8 5-4-8 6-1-0
Scale=1:45.5
Dead Load Defl.=1/4 in
4x4=
3x4= 5x6=
5 18 19 6 20 21 7
6.00 F12
2x4�� 22
4 23
CR2 3x4 11
8
3x4
17
3 q
2 A
d11
dd 72 11 10 24 25
3x8 11 3x8= 3x4 3x4
3x6=
9-7-0 17$3 26-5-0
9-7-0 7-11-3 8-10-13
Plate Offsets(XY)- [2:0-4-1,Edge).[7A-3-0,0-2-0]
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) 1/defl Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.50 Vert(LL) -0.16 9-10 >999 240 MT20 244/190
TCDL 10.0 Lumber Increase 1.25 BC 0.78 Vert(TL) -0.41 9-10 >769 180
BCLL 0.0 ' Rep Stress Incr YES WB 0.40 Horz(TL) 0.07 9 n/a n/a
BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:142 Ib FT=20%
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-11-8 oc purlins, except
BOT CHORD 2x4 SP No.2 end verticals.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 7-10-7 oc bracing.
SLIDER Left 2x4 SP No.3 1-6-0 WEBS 1 Row at midpt 7-9
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection,in accordance with Stabilizer
Installation guide.
REACTIONS. (Ib/size) 2=1133/0-6-0 (min.0-1-8),9=1049/Mechanical
Max Horz2=110(LC 11)
Max Uplift2=-304(LC 12),9=-246(LC 12)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 2-3=-1038/23,3-17=-1690/589,4-17=-1676/605,4-5=-1463/532,5-18=-1267/524,
18-19=-1267/524,6-19=-1267/524,6-20=-1192/480,20-21=-1192/480,7-21=-1192/480
BOT CHORD 2-12=-544/1453,11-12=-428/1334,10-11=-428/1334,10-24=-299/939,24-25=-299/939,
9-25=-299/939
WEBS 4-12=-264/189,5-12=-69/404,6-10=-363/181,7-10=-102/571,7-9=-1140/362
NOTES- (9)
1)Unbalanced roof live loads have been considered for this design.
2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf;BCDL=4.2psf;h=15ft;B=45ft;L=26ft;eave=4ft;Cat.ll;
Exp C;Encl.,GCpi=0.18;MW FRS(directional)and C-C Extedor(2)-1-4-0 to 1-8-0,Interior(1)1-8-0 to 9-7-0,Exterior(2)9-7-0 to 24-6-15,
Interior(1)24-6-15 to 26-3-4 zone;cantilever left and right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber
DOL=1.60 plate grip DOL=1.60
3)Provide adequate drainage to prevent water ponding.
4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5)"This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members,with BCDL=10.Opsf.
6)Refer to girder(s)for truss to truss connections.
7)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 304 Ib uplift at joint 2 and 246 Ib uplift at joint
9.
8)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
9)Segn:A0020052,Date:08/28/2014 `A
LOAD CASE(S) Standard AW-1!LICENSE••;��m
moi►
No.42704
STATE 8F
%X 0 R10,.P.•' tv
William M. Ranieri, P c # 42704
RISS Truss Type QtY Ply
040
728315 DA6 Roof Special Girder 1 1
Job Reference o tional a+9 No
American Builder's Supply,Sanford,FL 32771 Run:7.520 s Mayy 8 2014 Print:7.520 s May 82014 M7ek Industries,Inc.Thu Aug 2815:28:52 2014 Page 2
ID:c8A3zpKbMfNUP?G1 vJa8Yk9zZjN-qQLB5MdOxD8HONmXWQSLg21 edNKQK4TU?TO2Bzyj I_9
NOTES- (14)
13)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B).
14)Segn:AO020050,Date:08/28/2014
LOAD CASE(S) Standard
1)Dead+Roof Live(balanced):Lumber Increase=1.25,Plate Increase=1.25
Uniform Loads(plf)
Vert:1-5=-60,5-6=-60,6-11=-60,11-12=-60,13-20=-20
Concentrated Loads(lb)
Vert:9=-98(B)16=-887(B)26=-98(B)27=-98(B)28=-98(B)29=-98(B)31=-98(B)32=-98(B)33=-56(B)34=-56(B)35=-56(B)36=-56(B)37=-56(B)38=-56(B)39=-56(B)
'LICENSE'
r No.427p4
S .z STATE OF
r
� ..4 0 R1DsP�'�t1�'
y��DNAIti�
William M. Ranieri, P c # 2704
Job Truss Truss Type Qty Ply Dwg No036
728315 D13 Hip 1
I Job Reference(optional)
American Builders Supply,Sanford,FL 32771 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 M7ek Industries,Inc.Thu Aug 28 15:28:51 2014 Page 1
ID:cBA3zpKbMfN UP?GwJa8Yk9zZjN-MEnpuOcOAwORmDBKyjx68gUYz1 hbkCLmpeVfWy)I_A
1 4 0 6-9-11 13 00
16 11-0 23-1-5 29-11-0 _
1�0 6-9-11 6 2-5 3-11-0 6-2-5 6-9-11
Scale=1:51.6
4x8_ Dead Load Defl.=3/16 in
6.00 12 4x4=
6 25 26 7
3x4
27
3x4 5 3x4
4 6
N
r
28
3x4 3x4
3 44 9
2 10
q11
ccYY 15 14 13 12 11
2x411 3x4 3xB= 2x4 I I 3xB I I
3x8 3x4=
6-9-11 13 0 0 16 11-0 23-1-5 29-11-0
6-9-11 8-25 3-11-0 6-2-5 6-9.11
Plate Offsets[) Y)— 12.0-4-1 Edgel 16:0-5-4,0-2-01,[10:0-4-1 Edge]
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.57 Vert(LL) -0.10 14-15 >999 240 MT20 244/190
TCDL 10.0 Lumber Increase 1.25 BC 0.68 Vert(TL) -0.30 14-15 >999 180
BCLL 0.0 ' Rep Stress Incr YES WB 0.55 Horz(TL) 0.10 10 n/a n/a
BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M) Weight:1621b FT=20%
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-4-9 oc purlins.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 8-3-2 oc bracing.
WEBS 2x4 SP No.3 FWTek recommends that Stabilizers and required cross bracing
SLIDER Left 2x4 SP No.3 1-6-0,Right 2x4 SP No.3 1-6-0 be installed during truss erection,in accordance with Stabilizer
Installation guide.
REACTIONS. (Ib/size) 10=1195/0-6-0 (min.0-1-8),2=1278/0-6-0 (min.0-1-8)
Max Horz2=179(LC 11)
Max Uplift10=-277(LC 12),2=-341(LC 12)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 2-3=-835/128,3-24=-1993/619,4-24=-1979/640,4-5=-1532/552,5-6=-1444/569,
6-25=-1298/563,25-26=-1298/563,7-26=-1298/563,7-27=-1444/572,8-27=-1534/551,
8-28=-1868/645,9-28=-2003/631,9-10=-872/146
BOT CHORD 2-15=-507/1712,14-15=-507/1712,13-14=-311/1297,12-13=-311/1297,11-12=-490/1722,
10-11=-490/1722
WEBS 4-14=-528/229,6-14=-81/386,7-12=-106/387,8-12=-539/232
NOTES- (8)
1)Unbalanced roof live loads have been considered for this design.
2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf;BCDL=4.2psf;h=15ft;B=45ft;L=30ft;eave=4ft;Cat.II;
Exp C;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)-1-4-0to 1-8-0,Interior(1)1-8-0 to 13-0-0,Exterior(2)13-0-0 to
16-11-0,Interior(1)21-1-15 to 29-11-0 zone;cantilever left and right exposed;C-C for members and forces&MW FRS for reactions
shown;Lumber DOL=1.60 plate grip DOL=1.60
3)Provide adequate drainage to prevent water ponding.
4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5).This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 277 Ib uplift at joint 10 and 341 Ib uplift at
joint 2.
7)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
8)Segn:A0020048,Date:08/28/2014
LOAD CASE(S) Standard
4,
Ll
f N0.42704
STATE OF
► <0F10,,re f
William M. Ranieri, P c # 42704
Job Truss Truss Type Ply
' Dwg No 036
728315 D9 Hip 1 1
Job Reference(optional)
American Builders Supply,Sanford,FL 32771 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 Mi-Fek Industries,Inc.Thu Aug 28 15:28:49 2014 Paye 1
ID:c8A3zpKbMfNUP?GwJa8Yk9zZjN-Prf3TLb7elmjXwlyglve2PPCa9JZ7gA2JV90aeyil_C
140 4$14 900 14-11-0 20-11-0 2�r2-3 2911-0 31-3-Oi
r1�0 4$14 433 511-0 5118 432 4813 1-0-0
Scale=1:52.0
Dead Load Defl.=3/16 in
4x4= 3x8= 4x4=
5 2526 6 2728 7
6.00 12
2x4 2x4
4 8
IV 11,16 N
3X4 i 3x4
3 24 29 9
2 10
�1lal11
15 14 13 12
3x8 I I 3x8— 2x4 II 3x8= 3x8 11
9-0-0 _ 14-11-82011-0 29-11-0
9-0-0 511-8 _ 511 8 9-0-0
Plate Offsets(X,Y)— [2:0-4-1 Edge] [10:0-4-1 Edge]
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.55 Vert(LL) -0.12 15-18 >999 240 MT20 244/190
TCDL 10.0 Lumber Increase 1.25 BC 0.79 Vert(TL) -0.32 15-18 >999 180
BCLL 0.0 ' Rep Stress Incr YES WB 0.52 Horz(TL) 0.11 10 n/a n/a
BCDL 10.0 Code FBC2010/rP12007 (Matrix-M) Weight:158 Ib FT=20%
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-4-0 oc purlins.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 7-10-12 oc bracing.
WEBS 2x4 SP No.3 MiTek recommends that Stabilizers and required cross bracing
SLIDER Left 2x4 SP No.3 1-6-0,Right 2x4 SP No.3 1-6-0 be installed during truss erection,in accordance with Stabilizer
Installation guide.
REACTIONS. (Ib/size) 2=1277/0-6-0 (min.0-1-8),10=1277/0-6-0 (min.0-1-8)
Max Horz 2=-132(LC 10)
Max Uplift2=-339(LC 12),10=-339(LC 12)
FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 2-3=-1041/79,3-24=-1989/691,4-24=-1975/704,4-5=-1786/626,5-25=-1574/614,
25-26=-1574/614,6-26=-1574/614,6-27=-1574/614,27-28=-1574/614,7-28=-1574/614,
7-8=-1786/626,8-29=-1975/704,9-29=-1989/691,9-10=-1041/79
BOT CHORD 2-15=-527/1715,14-15=-495/1877,13-14=-495/1877,12-13=-495/1877,10-12=-542/1715
WEBS 515=-94/499,6-15=-481/173,6-12=-481/173,7-12=-94/499
NOTES- (8)
1)Unbalanced roof live loads have been considered for this design.
2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf;BCDL=4.2psf;h=15ft;B=45ft;L=30ft;eave=4ft;Cat.11;
Exp C;Encl.,GCpi=0.18;MWFRS(directional)and C-C Extedor(2)-1-4-0 to 1-8-0,Interior(1)1-8-0 to 9-0-0,Exterior(2)9-0-0 to 25-4-0,
Interior(1)25-4-0 to 31-3-0 zone;cantilever left and right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber
D0L=1.60 plate grip DOL=1.60
3)Provide adequate drainage to prevent water ponding.
4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 339 Ib uplift at joint 2 and 339 Ib uplift at joint
10.
7)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
8)Segn:AO020046,Date:08/28/2014
LOAD CASE(S) Standard l�
LICENSE�•;�
:� No•42704
STATE 8F 4
4.4
%0F1
William M. Ranieri, P c # 42704
JobNSS NSS ype ' Dwg No 0314
728315 DS Roof Special 1 1
Job R�efjerenceo tionalAmerican Builder's Supply,Sanford,FL 32771 Run:7.520 s May 8 2014 Print:7.520 s ay014 Mi Industries,Inc.Thu Aug 28 15:28:48 2014 Page 1
ID:c8A3zpKbMfN U P?GwJa8Yk9zZjN-xf5g F?aV u?esvmTm HaOP WCs 1 Om?MPNOv4r02Gyj
1-0-0 5-0-0 10-3 8 15.7-0 20 3-0 24 5 8 29-11-0 31-3.0
1�0 5 0 0 N 8 53b 4 8 0 42-8
Scale=1:52.6
Dead Load Defl.=7/16 in
4x4=
7
4x4= 2x4 11 4x4= 28 29 2x4 i
6.00 F12 4 5 8
5 26 27
3.4� 24 30 3x4-- c
23 9
3 10
2 11
1
14 13 12
3x8 11 3x10= 4x6— 3x8= 3x8 11
10-3-8 20-3-0 29-11-0
10-3-0 9-11-8 9-8-0
Plate Offsets( [2:04-1 Edge] [1 0:04-1,E
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.57 Vert(LL) -0.22 12-14 >999 240 MT20 244/190
TCDL 10.0 Lumber Increase 1.25 BC 0.66 Vert(TL) -0.65 12-14 >550 180
BCLL 0.0 Rep Stress Incr YES WB 0.51 Horz(TL) 0.10 10 n/a n/a
BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:145 lb FT=20%
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-0-6 oc pudins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 7-9-7 oc bracing.
WEBS 2x4 SP No.3 WEBS 1 Row at midpt 6-12
SLIDER Left 2x4 SP No.3 1-6-0,Right 2x4 SP No.3 1-6-0 Fbe
Tek recommends that Stabilizers and required cross bracing
installed during truss erection,in accordance with Stabilizer
stallation uide.
REACTIONS. (Ib/size) 2=1277/0-6-0 (min.0-1-8),10=1277/0-6-0 (min.0-1-8)
Max Horz 2=-140(LC 10)
Max Uplift2=-339(LC 12),10=-339(LC 12)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown.
TOP CHORD 2-3=-1127/37,3-23=-1977/650,23-24=-1963/652,4-24=-1954/664,4-25=-2891/914,
25-26=-2891/914,5-26=-2891/914,5-27=-2891/914,6-27=-2891/914,6-28=-1777/570,
7-28=-1717/581,7-29=-1719/584,8-29=-1773/572,8-30=-1971/633,9-30=-1986/617,
9-10=-1017/60
BOT CHORD 2-14=-491/1704,13-14=-878/3067,12-13=-878/3067,10-12=-474/1710
WEBS 4-14=-352/1351,514=-362/203,6-12=-1796/664,7-12=-343/1246,8-12=-260/168
NOTES- (8)
1)Unbalanced roof live loads have been considered for this design.
2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101mph;TCDL=4.2psf;BCDL=4.2psf;h=15ft;B=45ft;L=30ft;eave=4ft;Cat.Il;
Exp C;Encl.,GCpi=0.18;MWFRS(directional)and C-C Exterior(2)-1-4-0 to 1-8-0,Interior(1)1-8-0 to 50-0,Exterior(2)5-0-0 to 8-0-0,
Interior(1)15-7-0 to 31-3-0 zone;cantilever left and right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber
DOL=1.60 plate grip DOL=1.60
3)Provide adequate drainage to prevent water ponding.
4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5)`This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 339 Ib uplift at joint 2 and 339 Ib uplift at joint
10.
7)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
8)Segn:A0020044,Date:08/28/2014
LOAD CASE(S) Standard M
■
LICENSE�•;��s
s No.42704
STATE 8F
William M. Ranieri, P c # 42704
� � � # - � /
\ � �
d»
� ° )\
. \<
/� .(\
�\ �\ � - .
Plated Truss Connectors
LUS/MUS/HUS/HHUS/HGUS/HUSCDouble Shear JoistHangers
`�EERfp, This product is preferable to similar connectors because of 1"for 2xs
�v a)easier installation,b)higher loads,c)lower installed cost, i'lie for Vs
or a combination of these features. • �� P
All hangers in this series have double shear nailing—an
innovation that distributes the load through two points on each joist nail for • ;• •e
greater strength.This allows for fewer nails,faster installation,and the use e 3 o
of all common nails for the same connection. H ® 'e
Double shear hangers range from the light capacity LUS hangers to the e13as o '
highest capacity HGUS hangers.For medium load truss applications,the pr
MUS offers a lower cost alternative and easier installation than the HUS or . p
THA hangers,while providing greater load capacity and bearing than the LUS. • e c '
MATERIAL:See tables below and on page 135.
FINISH:Galvanized.Some products available in stainless steel or
ZMAX®coating;see Corrosion Information,page 14-15. w� D W HUS210
INSTALLATION •Use all specified fasteners.See General Notes. (HUS26,HUS28,
•Nails must be driven at an angle through the joist or truss into LUS28 6MUS28 and HHUS similar)
the header to achieve the table loads.
•Not designed for welded or nailer applications. M2"--I
OPTIONS:•LUS and MUS hangers cannot be modified. ,c •. < • • ° s
•HUS hangers available with the header flanges turned in for ° : `• < a s, 1
2-2x(3'/a)and 4x only,with no load reduction.See HUSC o < q : • ,
Concealed Flange illustration. s `° • H
•Concealed flanges are not available for HGUS and HHUS. ° H
•See Hanger Options,page 216,for sloped and/or skewed c ° • • ` ®q '• 6
HHUS models. a
•
•Other sizes available;consult your Simpson Strong-Tie representative. • / R
CODES:See page 13 for Code Reference Key Chart. ter'= °Bpi �w �� 4
.These products are available with additional corrosion protection. Wei HGUS28-2 �3 Mir
Additional products on this page may also be available with this option, H H U S210-2
'•• check with Simpson Strong-Tie for details. ♦ H U SC
v
e These products are approved for installation with the Strong-Drive SO r Concealed
C Structural-Connector screw.See page 27 for more information i�ii��r� Flanges
(not available
yMin. Dimensions Fasteners ,�;,�;,� for HHUS,
Model Heel Ga Carrying
Carried ir'i��i, HGUS and
No. Height W H B Member Member 'ii��iii °w HUS2x)SINGLE 2x SIZESca r `
. °
LUS24 2'/e 19/6 13/a 410d 210d (Truss Designer °
4 . 18 1.See table to provide fastener
'FU—S2-6 41/4 1'/,6 43/4 13/4 4-10d 4-10d on page quantity for connecting
MUS26 4"A6 18 19A6 5M6 2 6-10d 6-10d 135 for multiple members
HUS26 46/6 16 15/6 53/6 3 14-16d 616d allowable together) Typical HUS26 with
HGUS26 416 12 1% 5% 5 20-16d 8-16d loads. Reduced Heel Height
LUS28 43/,6 18 1�6 66/6 13/4 6-10d 4-10d w
MUS28 65/16 18 1'A6 6t3A6 2 8-10d 8-10d ® Double Shear Dome Double Shear
HUS28 6'/i 16 15/6 7 3 22-16d 8-16d Double Nailing Nailing Side View
Shear Side View (available on
HGUS28 69/16 12 11/e 71/s 5 36-16d 12-16d Nailing Do not some models) z
LUS210 41/4 18 19/,6 7i3/,6 13/4 8-10d 4-10d Top View bend tab a U.S.Patent 5,603,580 a
HUS210 8% 16 1M. 9 3 30 16d 1_61 6d
U
N
t7
FDFAllowable Loads SP Allowable Loads SPF/HF Allowable LoadsModel No Uplift' Snow Roof Wintl Uplift' Floor Snow Roof Wind Uplift'�(100)
Snow Roof Wind(160) (115) (125) (160) (160) (100) (115) (125) (160) (160) (115) (125) (160)
SINGLE 2x SIZES
LUS24 490 670 765 825 1045 490 725 830 895 1 1135 420 575 655 705 895
LUS26 1165 865 990 1070r1725
1165 940 1075 1165 1475 1005 740 845 915 1160
17,F6,L17
MUS26 1090 1295 1480 1605 1090 1410 1610 1745 1825 940 1110 1265 1370 1570
HUS26 1550 2720 3095 3335 1550 2950 3335 3335 3335 1335 2330 2650 2820 2865
HGUS26 1765 4360 4885 5230 1765 4725 5290 5390 5390 1520 3750 4200 4500 4635 L17
® LUS28 1165 1100 1255 1360 1165 1200 1365 1480 1835 1005 940 1075 1165 1475
MUS28 1555 1730 1975 1 2140 2645 1555 1880 2150 2330 2645 1335 1475 1690 1830 2275 17,F6,L17
HUS28 2000 3965 4120 4220 4335 2000 3790 3960 4070 4335 1720 2905 3035 3125 3435
HGUS28 3015 6745 6970 7125 7275 3015 6460 6705 6870 7275 2595 4960 5160 5290 5745 L17
LUS210 1165 1340 1525 1650 2090 1165 1445 1660 1795 2270 1005 1145 1305 1415 1745-
745 17,F6,L17
HUS210 3000 4255 4445 4575 5020 3000 4105 4310 4450 4930 2580 3150 3315 3425 3815
134 Note:For dimensions and fastener information,see table above. See table footnotes on page 135.
William M. Ranieri, PE FL Lic # 42704
FEBRUARY 8, 2008 LATERAL BRACING RECOMMENDATIONS ST-STRGBCK
— -- -- -----
�� O MiTek USA,Inc. Page 1 of 1
DO
moo TO MINIMIZE VIBRATION COMMON TO ALL SHALLOW FRAMING SYSTEMS,
2x6 "STRONGBACK" IS RECOMMENDED, LOCATED EVERY 8 TO 10 FEET
ALONG A FLOOR TRUSS.
MiTek USA,Inc.
NOTE 1:2X6 STRONGBACK ORIENTED VERTICALLY MAY BE POSITIONED DIRECTLY UNDER THE TOP CHORD OR DIRECTLY
ABOVE THE BOTTOM CHORD. SECURELY FASTENED TO THE TRUSS USING ANY OF THE METHODS ILLUSTRATED BELOW.
NOTE 2:STRONGBACK BRACING ALSO SATISFIES THE LATERAL BRACING REQUIREMENTS FOR THE BOTTOM CHORD OF
THE TRUSS WHEN IT IS PLACED ON TOP OF THE BOTTOM CHORD, IS CONTINUOUS FROM END TO END, CONNECTED
WITH A METHOD OTHER THAN METAL FRAMING ANCHOR,AND PROPERLY CONNECTED,BY OTHERS, AT THE ENDS.
ATTACH TO VERTICAL INSERT WOOD SCREW THROUGH OUTSIDE
L FRAMING ATTACH TO VERTICAL SCAB WITH(3)-10d NAILS FACE OF CHORD INTO EDGE OF STRONGBACK
USE META
ANCHOR L ATTACH WEB WITH(3)-10d NAILS (0.131"x 3") (DO NOT USE DRYWALL TYPE SCREWS)
TO TOP CHORD (0.131"x 3")
ATTACH TO VERTICAL
WEB WITH(3)-10d NAILS
(0.131"x 3")
i
BLOCKING BEHIND THE ATTACH 2x4 VERTICAL TO FACE ATTACH TO CHORD
VERTICAL WEB IS OF TRUSS. FASTEN TO TOP AND WITH TWO#12 x 3"
RECOMMENDED WHILE BOTTOM CHORD WITH(2)-10d WOOD SCREWS(.216"DIAM.)
NAILING THE STRONGBACK NAILS(0.131"x 3")IN EACH CHORD
ATTACH TO VERTICAL INSERT SCREW THROUGH OUTSIDE
USE METAL FRAMING ATTACH TO VERTICAL
ANCHOR TO ATTACH WEB WITH(3)-10d NAILS SCAB WITH(3)-10d NAILS FACECHORD INTO EDGE OF
TO BOTTOM CHORD (0.131"x 3") STRONGBACK
BACK(DO NOT USE
(0.131"x 3") DRYWALL TYPE SCREWS)
4-0-0 WALL BLOCKING
TRUSS STRONGBACK (TYPICAL SPLICE) (BY OTHERS) (BY OTHERS)
4 y::
THE STRONGBACKS SHALL BE SECURED AT THEIR ENDS TO ADEQUATE SUPPORT,
DESIGNED BY OTHERS.IF SPLICING IS NECESSARY,USE A 4'-0"LONG
SCAB CENTERED ON THE SPLICE AND JOINED WITH(12)- 10d NAILS
(0.131"x 3") EQUALLY SPACED. `���•........� /
ALTERNATE METHOD OF SPLICING: = LICENSE
OVERLAP STRONGBACK MEMBERS A MINIMUM OF 4'-0"AND FASTEN WITH(12) 10d :•
NAILS(0.131"x 3") STAGGERED AND EQUALLY SPACED.
(TO BE USED ONLY WHEN STRONGBACK IS NOT ALIGNED WITH A VERTICAL) d No.42704
s STATE OF
*�
William M. Ranieri, P c # 42704
TYPICAL GABLE END DETAIL
TYPICAL PIATONAL PFACE
ATTAC&P TO VEr, CAL- TYPICAL IXC}01?2X4 "L"
5EE TANEOp MAXIMUM PPACE,(IE AFFUCAJN,. ),
HEIGHT5 NALE17 TO VEt CA-
5EE TAU EO< MAX,
HEIGHT5
12 MAtClf5
COMMON
Al 13raanq to be a Minimum
5PF Stud Grade or better
TYPICAL GABLE END
Externa-Grade 5heathlnq
MINIMUM GRADE OF LUMBER
TOP CHORD (2x4): NO. 2 5YP
BOT GHORD (2x4): NO. 2 5YP
WEB5 (2x4): NO. 3 5YP I0 X 20 13
A5 Q�QUIQT
(2) CONNECTOR PLATE5 MINIMUM
(1) 20 GAUGE AT EVERY JOINT
"L"BRACE DETAIL
TYPICAL LOADING (P.5.F.) NOTE;
TILE: SHINGLES: 1) USE 6J GUN NAIL5 AT 4" O.G. FOR 1x4 AND
TOP LIVE LOAD: 20 20 1Od AT 4" O.G. FOR 2x4.
TOP DEAD LOAD: 15 7
BOTTOM DEAD LOAD: 10 10 2) IF 5TRUCTURAL SHEATHING 15 U5ED ON THE
TOTAL: 45 37 FACE OF GABLE THE ENGINEER OF REGORD
5TRE55 INC. 1.25 1.25 MAY DEEM L-BRAGING UNNEGE55ARY.
MAXIMUM HEIGHT TADLE
WIND VELOGITY - 140 M.P.H.
5PAGING OF MAX. LENGTH MAX. LENGTH MAX. LENGTH MAX. LENGTH
VERTICAL5 NO BRACE 10 BRACE 2x4 BRACE` 2x6 BRACE
12" 4 2" 611" 6.q., 13'10"
16" 3'10" 5'11" 7'10" 1213"
24" 3'4" 4.10.1 6-5" 10,01,
BEYOND TH15 LENGTH U5E 2x6.
M
William M. Rani
American FLORIDA PROFESSI L?GS
Builders No.# 42 e4
No.4270
Z7;d- Supply
1000 Carroll Street-Clermont,F1.34711 Phone:352-394-2116 Fax:352-394-1968fir
E
- •% X
William M. Ranieri, P c # 42704
TYPICAL PIGGYBACK ATTACHMENT DETAIL
20 PbP.LIN5-At 48'' O.C.
SHIM EO?FULL CON19cf
5EE NOTE #3C 5EE NOTE #I
5EE NOTE #313 SEE NOTE #23
5EE NOTE #2A IGGY(3 TRU55
!NTEt?EACE INTERFACE
5EE NOTE #2A 5EE NOfE #3A
D 55
TYPICAL LOADING (P.5.F.) 5�� NOTA #2C
TILE: SHINGLES: 1MVFAa
TOP LIVE LOAD: 20 20
TOP DEAD LOAD: 15 7
60TTOM DEAD LOAD: 10 10
TOTAL: 45 37
5TRE55 INC. 1.25 1.25
WIND DE51GN: MAX. 140 M'FrHR
ASGE 7-10
NST
I) 2x4 PURLINS ON FLAT TOP CHORD SECTION OF DASE TRU55 AT ALL JOINT5,
NOT TO EXCEED 4'-0" O.G. OR THE MAXIMUM ALLOWABLE PURLIN SPAGING
OF DASE TRU55- (5EE DA5E TRU55 ENGINEERING FOR MAX. 5PAGING)
ATTACH PURLIN5 TO TOP CHORD OF DASE TRU55 WITH MIN. 2 EA. 10d NAIL5
2) IF 5HEATHING DOE5 NOT OVERLAP PIGGYBACK / DA5E TRU55 INTERFACE DY AT
LEAST 12" ATTACH PIGGY 13ACK U5ING ONE OF THE FOLLOWING:
a- 1-1/4" X 12" 20 GAUGE STRAP (U5P # L13TA-12 OR EQUIVALENT) TO ONE 51DE OF
TRU55 CENTERED ON INTERFACE WITH MIN. 5 EA. 8D NAIL5 EACH 51DE OF INTERFACE;
b- 2 X 4 X 4'-0" GRADED SGAD TO ONE 51PE OF TRU55 CENTERED
ON INTERFACE WITH MIN. 10d NAIL5 5TAG6ERED 3" O.G. FULL LENGTH OF SGAD;
c- 6" X 8" NOM. 1/2" STRUGTURAL 5HEATHIN6 6U55ET PLATE TO DOTH 51DE5 OF
TRU55 CENTERED ON INTERFACE WITH MIN. 5 EA. 8d NAIL5 EACH 51DE OF INTERFACE.
3) FOR PIGGYDACKS OVER 16'-0" IN LENGTH USE ONE OF THE FOLLOWING
IN ADDITION TO THE ADOVE REQUIREMENTS
a- ATTACH MITEK 16 go 7H HAMMER ON PLATE5 ON EACH 51DE OF TRU55 AT EACH
DASE TRU55 JOINT;
b- U5P FRAMING ANCHOR HGDP OR 5IMP50N H 2.5, ONE CONNECTED TO PIGGYDAGK AND
PURLIN, AND ONE CONNECTED TO PURLIN AND DASE TRU55 5TARTIN6 AT MIDDLE
OF PIGGYDAGK AND EVERY OTHER PURLIN;
c- 6" X8" 1/2" 5TRUCTURAL 5HEATHING 6U55ET PLATE AT EACH DASE TRU55 JOINT,
DOTH 51DE5 OF TRU55, U51N6 MIN. 3 EACH 6d NAI1_5 EACH CHORD- (TOTAL 12 NAIL5)
William M.
American FLORIDA PROFE
4AB S Builders LICENS #PE:12_k .42704
•,e
ampBna Supply * s
1
1000 Carroll Street-Clermont,Fl.34711 Phone:352-394-2116 Fax:352-394-1968
we
ti a
or N
NAL
William M. Ranieri, P c # 42704
s
w 0
LLI0 O LU(f)
(� frZ Z D
w zw -CC
Q w� �J Q
w
J Q� aYQ LLD
=JO=�� w cn> co0
N—
(DU(Dx" � D�
w
zvzC4(D O i::LU =�
LLJ X LLJ G�Zz
J2�'JOLLJ�p QLIJ WO
&4 LIJ>LU �o < Jw �Q K
z F_�=W 2i LLJ O Cf) _LLJ LU
Q�J- 0 0 w
���XU� ~ w o
x C"" LLJ
m tY
N N 2 -<Za- cn CC O(1)W�oO_p� ) � H=Q
co O__ W O_ W 3
->N Nu acnm F_ 0 <w�o
00000m0� J z _
I—O_ W Q w >-:E F-O
�QO_v�= = zv J���
�N �� W Q
Ww-- p 0w Q>�
DUZCJw -ow >OwQ
O0n-OOQm --c 0_00
Li F- O
LL1Q'ZWOOJ Z JW<�
W N O W�U o0 CD : 'J-j 0
00�(oZ0Z ZL)= U_
WO <C14 pLL
Z Q��W�Qa �cnooQC
W �0�COOZ lI SCI chWX
J J
J xLL
Q N=Cf)¢ _'=OOZ >�U)zZW
> wF.O'cnWUO Q N::)LL,cn
ca(D —W I— ��=--m(n
QOZv�LLZZ "OD_`D0D
HW_QQZW W ZF—
cf)(if 0 OY O> _j >a ch
LU O-0Y01 =0z LLQ Jc)�OF---
W ��p�UQ�OU 0m" >?�cn_jo
LL LL zw wF_�wF_Q
O Q Q W 2E1— O=wI—DO-
wU�
QZOZ HwO�0�
> W� O_CV QJ U)
a-LLQ UCCwQWm
c�=> gTM0>UU)
W xW=UZ w NUQOCC=� NZ ZwaY
<a-
- William M. ICENS••••
American FLORIDA PROFES ENGINEE
Ut
LICENSE IPE P7cpQ•427
Builders
_amr&,gBunlers supply STATE
juppl.
1000 Carroll Street-Clermont,Fl.34711 Phone:352-394-2116 Fax:352-394-1968
William M. Ranieri, P c # 42704
o rues nrss ype
Dw9 No 132
728315 ViX Valley t t�Qty ply Job Reference(optional)
American Builder's Supply,Sanford,FL 32771 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 Walk Industries,Inc.Thu Aug 2815:29:28 2014 Page 1
ID:�A3zpKbMfN UP?GwJa8Yk9z4N-mMWofg3bTHhBivWSd_6o8eX_kupBmasnH36yRtyjHzb
7-3-12 14-7-8
7-3-12 7-3-12
Scale=1:23.0
4x4=
5
6
4
6.00 12
7
3 19
18
20
17 8
2 T1
T
T
9
1
B1
3x4 16 15 14 13 12 11 10 3x4
14-7-8
14-7-8
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.10 Vert(LL) n/a n/a 999 MT20 244/190
TCDL 10.0 Lumber Increase 1.25 BC 0.05 Vert(TL) n/a n/a 999
BCLL 0.0 ' Rep Stress Incr YES WB 0.07 Horz(TL) 0.00 9 n/a n/a
BCDL 10.0 Code FBC2010/TP12007 (Matrix) Weight:64 Ib FT=20%
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-M oc bracing.
OTHERS 2x4 SP No.3 MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection,in accordance with Stabilizer
Installation guide.
REACTIONS. All bearings 14-7-8.
(Ib)- Max Horz 1=-82(LC 10)
Max Uplift All uplift 100 Ib or less at joint(s)1,9,14,15,16,12,11,10
Max Grav All reactions 250 Ib or less at joint(s)1,9,13,14,15,16,12,11,10
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
NOTES- (11)
1)Unbalanced roof live loads have been considered for this design.
2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf;BCDL=4.2psf;h=15ft;B=45ft;L=24ft;eave=2ft;Cat.Il;
Exp C;Encl.,GCpi=0.18;MWFRS(directional)and C-C Comer(3)0-7-7 to 3-7-7,Exterior(2)3-7-7 to 7-3-12,Comer(3)7-3-12 to 10-3-12
zone;cantilever left and right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip
DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind(normal to the face),see Standard Industry
Gable End Details as applicable,or consult qualified building designer as per ANSI/TPI 1.
4)All plates are 2x4 MT20 unless otherwise indicated.
5)Gable requires continuous bottom chord bearing.
6)Gable studs spaced at 1-4-0 oc.
7)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
9)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s)1,9,14,15,16,12,11
10.
10)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
11)Segn:A0020142,Date:08/28/2014
LOAD CASE(S) Standard
M.
� ��►.� LIC ENSE�•;��m
No.42704
s STATE OF 4
. Ry
,c<d R1p,,�,',.
mss......, �.�
�DNAtti
William M. Ranieri, P # 42704
ru
niss ss YPe a+9 No 129
728315 VT1 Valley 1 1
Job Reference o tional
American Builders Supply,Sanford,FL 32771 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MiTek Industries,Inc. Thu Aug 2815:29:27 2014 Page 1
I D:c8A3zpKbMfNU P?GwJa8Yk9zZjjN-19yQRK2zi_ZK4mxF3HaZbQ_m4UQN 18re2QN PvRyjHzc
5-312 10-7-8
5312 5-312
Scale=1:17.9
4x4=
2
6.00 12
7
6
8
5 ST1
3
1
B1
4
2x4% 2x4 11 2x4\
0- 8 10-7-8
8 70-7-0
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.28 Vert(LL) n/a n/a 999 MT20 244/190
TCDL 10.0 Lumber Increase 1.25 BC 0.22 Vert(TL) n/a n/a 999
BCLL 0.0 ' Rep Stress Incr YES WB 0.06 Horz(TL) 0.00 3 n/a n/a
BCDL 10.0 Code FBC2010ITP12007 (Matrix) Weight:34 Ib FT20%
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3 [tinstallation
Tek recommends that Stabilizers and required cross bracing
installed during truss erection,in accordance with Stabilizer
nide. —
REACTIONS. (Ib/size) 1=171/10-6-8 (min.0-1-8),3=171/10-6-8 (min.0-1-8),4=408/10-6-8 (min.0-1-8)
Max Horz 1=-57(LC 10)
Max Upliftl=-50(LC 12),3=-50(LC 12),4=-73(LC 12)
Max Gravl=173(LC 21),3=173(LC 22),4=408(LC 1)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
WEBS 2-4=-270/173
NOTES- (8)
1)Unbalanced roof live loads have been considered for this design.
2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf;BCDL=4.2psf;h=15ft;B=45ft;L=24ft;eave=4ft;Cat.II;
Exp C;Encl.,GCpi=0.18;MW FRS(directional)and C-C Exterior(2)0-7-9 to 3-7-9,Interior(1)3-7-9 to 5-3-12,Exterior(2)5-3-12 to 8-3-12
zone;cantilever left and right exposed;C-C for members and forces&MW FRS for reactions shown;Lumber DOL=1.60 plate grip
DOL=1.60
3)Gable requires continuous bottom chord bearing.
4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s)1,3,4.
7)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
8)Segn:A0020139,Date:08/28/2014
LOAD CASE(S) Standard
li'■
LICENSE"•.���
No.42704
STATE OF
0 MID
�DNAI.�
William M. Ranieri, P c # 42704
NsS Russ We Fly
Ng No 127
728315 KG1S Diagonal Hip Girder 1 1
LRefernoe optional)
American Builder's Supply,Sanford,FL 32771 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MTek Industries,Inc.Thu Aug 28 15:29:26 2014 Page 1
ID:c8A3zpKbMfNUP?GwJa8Yk9zZtjN-qzO2E_1 LxgRTTcM3VZ3K2DRaO44hIhSUgmdsN?yjHzd
6-3-14 7-fr14
6-3-14 130
Scale:1/2"=1'
3
3x4
Special
5.54 12 S al 2
PeG
8
T1 A R
N
V
El
3x4=
7
1 O
B7 N
8 e
94
8
5
Special 3x4 11
3x6 11 Special
6314
6-3-12
Plate Offsets(X, -1-8]
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.37 Vert(LL) -0.02 4-5 >999 240 MT20 244/190
TCDL 10.0 Lumber Increase 1.25 BC 0.25 Vert(TL) -0.06 4-5 >999 180
BCLL 0.0 ' Rep Stress Incr NO WB 0.00 Horz(TL) -0.00 7 n/a n/a
BCDL 10.0 Code FBC2010/TP12007 (Matrix-M) Weight:29 Ib FT=20%
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
BOT CHORD 2x4 SP No-2 end verticals.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection,in accordance with Stabilizer
Installation guide.
REACTIONS. (Ib/size) 5=222/0-6-3 (min.0-1-8),7=266/0-1-8 (min.0-1-8)
Max Horz 5=136(LC 8)
Max Uplift5=4(LC 4),7=-189(LC 8)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown.
NOTES- (10)
1)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf;BCDL=4.2psf;h=15ft;B=45ft;L=24ft;eave=4ft;Cat.Il;
Exp C;Encl.,GCpi=0.18;MW FRS(directional);cantilever left and right exposed;Lumber DOL=1.60 plate grip DOL=1.60
2)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4)Bearing at joint(s)7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of
bearing surface.
5)Provide mechanical connection(by others)of truss to bearing plate at joint(s)7.
6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s)5 except Qt=lb)7=189.
7)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
8)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)143 Ib down and 152 Ib up at 5-0-12
,and 143 Ib down and 152 Ib up at 5-0-11 on top chord,and 27 Ib down and 34 Ib up at 5-0-12,and 27 Ib down and 34 Ib up at 5-0-11
on bottom chord. The design/selection of such connection device(s)is the responsibility of others.
9)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B).
10)Segn:AO020137,Date:08/28/2014
LOAD CASE(S) Standard
1)Dead+Roof Live(balanced):Lumber Increase=1.25,Plate Increase=1.25
Uniform Loads(plf)
Vert:1-2=-60,2-3=-60,4-5=-20 1 ■■
Concentrated Loads(lb) M
Vert:8=76(F=38,B=38)9=-3(F=-1,B=-1)
N0.427Q4
i STATE OF e�
• �4
�.<4 Rlps••' �
tt
William M. Ranieri, P # 42704
Job runs Truss Type
a+'9 No 128
728315 KG Monopitch Girder 2Qly ply 1
Job Reference o tional)
American Builder's Supply,Sardad,FL 32771 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 M7ek Industries,Inc. Thu Aug 2815:29:25 2014 Page 1
I D:c8A3zpKbMfN UP?GwJa8Yk9zZEN-Mngg0e0jAMlcrSotxsYSW?vPtgifZCKLb6ulgYyjHze
-1-5-5 3-10-9 7-9-2
1-5 5 3-10-9 3 las
Scale=1:28.6
4
2x4
NAILED
554 F1-2 NAILED
3x4 10
3
T1
1
2
1 B1
`1 t 6 11 12 5
2x4 11 NAILED 4x4=
3x4= SPAN
NAILED
Special
3-10-9 7-9-2
3-10-9 3.10-9
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.33 Vert(LL) -0.02 5-6 >999 240 MT20 244/190
TCDL 10.0 Lumber Increase 1.25 BC 0.43 Vert(TL) -0.03 5-6 >999 180
BCLL 0.0 ' Rep Stress Incr NO WB 0.18 Horz(TL) 0.00 5 n/a n/a
BCDL 10.0 Code FBC2010(TPI2007 (Matrix-M) Weight:47 Ib FT=20%
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
BOT CHORD 2x6 SP No.2 end verticals.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection,in accordance with Stabilizer
Installation guide. _
REACTIONS. (Ib/size) 2=461/0-6-5 (min.0-1-8),5=510/Mechanical
Max Horz 2=161(LC 8)
Max Uplift2=-145(LC 8),5=-201(LC 8)
FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 2-3=-547/199
BOT CHORD 2-6=-183/449,6-11=-183/449,11-12=-1831449,5-12=-183/449
WEBS 3-6=-58/304,3-5=-513/209
NOTES- (10)
1)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf;BCDL=4.2psf;h=15ft;B=45ft;L=24ft;eave=4ft;Cat.11;
Exp C;Encl.,GCpi=0.18;MWFRS(directional);cantilever left and right exposed;Lumber DOL=1.60 plate grip DOL=1.60
2)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4)Refer to girder(s)for truss to truss connections.
5)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s)except Qt=1b)2=145,
5=201.
6)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
7)"NAILED"indicates 2-12d(0.148"x3.25")toe-nails.For more details refer to MiTek's ST-TOENAIL Detail.
8)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)169 Ib down and 88 Ib up at 5-8-2,
and 189 Ib down and 88 Ib up at 5-8-1 on bottom chord. The design/selection of such connection device(s)is the responsibility of
others.
9)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B).
10)Segn:A0020138,Date:08/28/2014
LOAD CASE(S) Standard
1)Dead+Roof Live(balanced):Lumber Increase=1.25,Plate Increase=1.25
Uniform Loads 4 n
Vert:1-4=-=-60,5-7=-20
Concentrated Loads(lb) .•••����••`••
Vert:10=92(F=46,B=46)11=11(F=6,B=6)12=-379(F=-189,B=-189) ;`•LICE NSE•`;��¢
fe No.427p4
STATE OF
. tv
William M. Ranieri, P c # 42704
N55 NSS YPe Uwg No 1[4
728315 K Common Girder
1
Job Referenceo tional
nfond,R.32771 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 M7ek Industries,Inc.Thu Aug2815:29:24 2014 Page 2
American Builders Supply,Se
ID:c8A3zpKbMfNUP?GwJa8Yk9zZj N-uaGHpJ04P3AIDIDgO81 szoMBjGGSgdUCMS8116y]Hzf
LOAD CASE(S) Standard
1)Dead+Roof Live(balanced):Lumber Increase=125,Plate Increase=1.25
Uniform Loads(plf)
Vert:1-0=-60,4-6=-60,8-11=-20
Concentrated Loads(lb)
Vert:7=-977(F=-488,B=-488)14=92(F=46,13=46)15=76(F=38,13=38)16=11(F=6,B=6)17=-379(F=-189,B=-190)18=-379(F=-189,B=-190)19=3(F=-1,B=-1)
M.
' LICENSE•;���
No.42704 i
* : :* �
STATE OF Jf
0 HID
ti
William M. Ranieri, P c # 42704
cuss I runs I ype Dog No 1231
728315 ix Monopilch Supported Gavle 1 1
�Jbn. al)
American Build Suppy,Sanford,FL 32771 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 Mi7ek Industries,Inc. Thu Aug 2815:29:23 2014 Page 1
I D:c8A3zpKb MfN U P?GwJa8Yk9zZll N-QOjvbz?Sel2 ucBeUq RWd Rap6At555Kg27oPBmgyjHzg
11-11-8 -
1�-0 11-11-8
Scale=1:20.8
9
8
3.00 12 6
18 7
5
4
3 T1 1
ST4
17 ST
ST6
2
Li B1
16 15 14 13 12 11 10
3x4=
I
LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) I/defl Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.15 Vert(LL) 0.00 1 n/r 120 MT20 2441190
TCDL 10.0 Lumber Increase 1.25 BC 0.11 Vert(TL) 0.01 1 nlr 120
BCLL 0.0 ' Rep Stress Incr YES WB 0.06 Horz(TL) -0.00 10 n/a nla
BCDL 10.0 Code FBC2010/TPI2007 (Matrix) Weight:57 Ib FT=20%
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
BOT CHORD 2x4 SP Not end verticals.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2x4 SP No.3 7MiTek recommends thatStabilizers and required cross bracing
talled during truss erection,in accordance with Stabilizer
ation guide.
REACTIONS. All bearings l l-11-8.
(lb)- Max Horz 2=122(LC 12)
Max Uplift All uplift 100 Ib or less at joint(s)10,2,11,12,13,14,15,16
Max Grav All reactions 250 Ib or less at joint(s)10,2,11,12,13,14,15 except 16=308(LC 1)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown.
NOTES- (11)
1)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf;BCDL=4.2psf;h=15ft;B=45ft;L=24ft;eave=2ft;Cat.ll;
Exp C;Encl.,GCpi=0.18;MWFRS(directional)and C-C Comer(3)-1-4-0 to 1-8-0,Exterior(2)1-8-0 to 11-9-12 zone;cantilever left and
right exposed;C-C for members and forces&MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind(normal to the face),see Standard Industry
Gable End Details as applicable,or consult qualified building designer as per ANSI/TPI 1.
3)All plates are 2x4 MT20 unless otherwise indicated.
4)Gable requires continuous bottom chord bearing.
5)Gable studs spaced at 1-4-0 oc.
6)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7).This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
8)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s)10,2,11,12,13,14,
15,16.
9)Beveled plate or shim required to provide full bearing surface with truss chord at joint(s)2.
10)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
11)Segn:A0020133,Date:08/28/2014
LOAD CASE(S) Standard
'LICENSE
�►
N0.42704
z STATE OF
0 F1110 60
William M. Ranieri, P c # 42704
o ruse cussType ply
Dog No 111
728315 HJ28 Diagonal Hip Girder 1 t
Job Reference(optional)
American Builder's Supply,Sanford,FL 32771 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 M7ek Industries,Inc.Thu Aug 28 15:29:22 2014 Page 1
I D:c8A3zpKbMfNUP?GwJa8Yk9zZjN-yC9XOd_gtRw1_31Gj?OuNHtXTjEMtTvv8feEDyjHzh
-1-10-10 3-9-3
1-10-10 — 3-9-3
Scale=1:13.4
3
4.24 12 Special
Special
6
y T1
1
B1
7 4
Special
Special
5
3x8 I I
3-9-3
3-9-3
Plate Offsets(X,Y)- [5:0-4-4,0-1-8]
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/def! L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.40 Vert(LL) 0.01 4-5 >999 240 MT20 244/190
TCDL 10.0 Lumber Increase 1.25 BC 0.22 Vert(TL) 0.02 4-5 >999 180
BCLL 0.0 ' Rep Stress Incr NO WB 0.00 Horz(TL) -0.02 3 n/a n/a
BCDL 10.0 Code FBC2010ITP12007 (Matrix-M) Weight:15 Ib FT=20%
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-9-3 oc purlins, except
BOT CHORD 2x4 SP No.2 end verticals.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection,in accordance with Stabilizer
Installation guide.
REACTIONS. (Ib/size) 5=215/0-8-2 (min.0-1-8),3=50/Mechanical,4=6/Mechanical
Max Hoa 5=83(LC 8)
Max Uplift5=-127(LC 8),3=-29(LC 5),4=-16(LC 17)
Max Grav5=215(LC 1),3=62(LC 28),4=28(LC 3)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown.
NOTES- (9)
1)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf;BCDL=4.2psf;h=15ft;B=45ft;L=24ft;eave=4ft;Cat.ll;
Exp C;Encl.,GCpi=0.18;MWFRS(directional);cantilever left and right exposed;Lumber DOL=1.60 plate grip DOL=1.60
2)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4)Refer to girder(s)for truss to truss connections.
5)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s)3,4 except(jt=lb)
5=127.
6)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
7)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)67 Ib down and 123 Ib up at 1-6-1,
and 67 Ib down and 123 Ib up at 1-6-1 on top chord,and 48 Ib up at 1-6-1,and 48 Ib up at 1-6-1 on bottom chord. The design/selection
of such connection device(s)is the responsibility of others.
8)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B).
9)Segn:AO020131,Date:08/28/2014
LOAD CASE(S) Standard
1)Dead+Roof Live(balanced):Lumber Increase=1.25,Plate Increase=1.25
Uniform Loads
Vert:1-2(=-=-
60,2-3=-60,4-5=-20
Concentrated Loads(lb)
Vert:6=81(F=41,B=41)7=55(F=27,B=27)
LICENSE :.����
s No.427Q4
STATE OF
t r+
�.�o RIP lite �
�DNAIL�
William M. Ranieri, P # 42704
o RISS russ Dv g No 119
728315 HJ7 Diagonal Hip Girder 1 1
Job Referenceoptional)
American Builders Supply,Sarrford,FL 32771 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 Walk Industries,Inc.Thu Aug 28 15:29:20 2014 Page 1
I1):c8A3zpKbMfNU P?GwJa8Yk9z74jN-?p 1 nD¢aLggJlhvv9JywpyBTGfyguw9cRgAX9LyjHzj
-1-10-10 4-11-0 9-10-1
1-10-10 4-11-0 4-11-0
4 Scale=1:25.6
Dead Load Deft.=1/8 in
Special
Special
11
4.24 12
Special 3x4
Special 3
10
Special T1
Special
9
2
1 81
12 13 7 14 6
8 SP I Special 2x4 11 Special 5
3x6 II Speciall Special Special 3x4=
4-11-0 9-10-1
4-11-0 4-11-0
Plate Offsets(XY7 [8:0-3-4 0-1-0]
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.64 Vert(LL) -0.05 6-7 >999 240 MT20 244/190
TCDL 10.0 Lumber Increase 1.25 BC 0.54 Vert(TL) -0.14 6-7 >801 180
BCLL 0.0 Rep Stress Incr NO WB 0.24 Horz(TL) -0.04 4 n/a n/a Weight:43 Ib FT=20%
BCDL 10.0 Code FBC2010ITP12007 (Matrix-M)
LUMBER- BRACING-
TOP CHORD 2x4 SP Not TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
BOT CHORD 2x4 SP No.2 end verticals.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
[installation
installed during truss erection,in accordance with Stabilizer
guide. —
REACTIONS. (Ib/size) 8=335/0-5-5 (min.0-1-8),4=166/Mechanical,5=244/Mechanical
Max Horz 8=159(LC 8)
Max Uplift8=-149(LC 8),4=-91(LC 8),5=-52(LC 5)
Max Grav8=391(LC 17),4=166(LC 1),5=267(LC 3)
FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 2-8=-406/130,2-9=-524/184,9-10=-509/169,3-10=-4591133
BOT CHORD 8-12=-168/434,12-13=-168/434,7-13=-168/434,7-14=-168/434,6-14=-168/434
WEBS 3-6=-477/184
NOTES- (9)
1)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf;BCDL=4.2psf;h=15ft;B=45ft;1_=24ft;eave=4ft;Cat.11;
Exp C;Encl.,GCpi=0.18;MWFRS(directional);cantilever left and right exposed;Lumber DOL=1.60 plate grip DOL=1.60
2)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3)`This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4)Refer to girder(s)for truss to truss connections.
5)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s)4,5 except Qt=lb)
8=149.
6)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
7)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)49 Ib down and 80 Ib up at 1-6-1,49
Ib down and 80 Ib up at 1-6-1,80 Ib down and 71 Ib up at 4-4-0,80 Ib down and 71 Ib up at 4-4-0,and 115 Ib down and 106 Ib up at
7-1-15,and 115 Ib down and 106 Ib up at 7-1-15 on top chord,and 22 Ib down and 53 Ib up at 1-6-1,22 Ib down and 53 Ib up at 1-6-1,
18 Ib down and 18 Ib up at 4-4-0,18 Ib down and 18 Ib up at 4-4-0,and 39 Ib down and 9 Ib up at 7-1-15,and 39 Ib down and 9 Ib up at
7-1-15 on bottom chord. The design/selection of such connection device(s)is the responsibility of others.
8)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). �
9)Segn:A0020129,Date:08/28/2014 ■
LOAD CASE(S) StandardLl
�.•+m•+•.
1)Dead+Roof Live(balanced):Lumber Increase=1.25,Plate Increase=1.25 •'• '
Uniform Loads(plf) �� •�LICENSE•';� ih
Vert:1-2=-60,2-4=-60,5-8=-20 SII► t1 + �
Concentrated Loads(lb)
49(F=-24 8=-2 No.42704
Vert:9=159(F=80,B=80)10=44(F=22,B=22)11=-78(F=-39,B=-39)12=61(F=31,B=31)13=9(F=5,B=5)14= ,
STATE OF '�F
William M. Ranieri, P c # 42704
=1"U'-s's
Ns3 ype , Dwg No 117
728315 Diagonal Hip Girder 2 1
Job Reference(oQonal)American Buiklets Supply,Sanford, L 32771 Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 M7ek Industries,Inc.Thu A.9 28 15:29:19 2014 Page 1
ID:c8A3zpKbMfNU P?GwJa8Yk9z4N-XdTOmbyya WYS7XKjbb RhGkfMDFhQ9WjTCAR_dvyjHzk
-1-10-10 4-2-3
1-10 10 4-2-3
Scale=1:14.1
3
4.24 12�al
Special
6
m�
T1 N
2
1
B1
7 4
Special
Special
5 3x8 11
4-2-3
�— 4-2-3
Plate Offsets(X,Y)— 15:0-4-4.0-1-81
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.41 Vert(LL) 0.02 4-5 >999 240 MT20 244/190
TCDL 10.0 Lumber Increase 125 BC 0.22 Vert(TL) 0.03 4-5 >999 180
BCLL 0.0 ' Rep Stress Incr NO WB 0.00 Horz(TL) -0.02 3 nla nla Weight:16 Ib FT=20%
BCDL 10.0 Code FBC2010/TP12007 (Matrix-M)
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-2-3 oc purlins, except
BOT CHORD 2x4 SP No.2 end verticals.
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection,in accordance with Stabilizer
Installation guide.
REACTIONS. (Ib/size) 5=222/0-3-14 (min.0-1-8),3=67/Mechanical,4=14/Mechanical
Max Horz 5=89(LC 8)
Max Uplift5=-127(LC 8),3=-36(LC 8),4=-6(LC 17)
Max Grav5=222(LC 1),3=75(LC 28),4=39(LC 3)
FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown.
NOTES- (9)
1)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf;BCDL=4.2psf;h=15ft;B=45ft;L=24ft;eave=4ft;Cat.II;
Exp C;Encl.,GCpi=0.18;MW FRS(directional);cantilever left and right exposed;Lumber DOL=1.60 plate grip DOL=1.60
2)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4)Refer to girder(s)for truss to truss connections.
5)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s)3,4 except Qt=1b)
5=127.
6)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
7)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)67 Ib down and 123 Ib up at 1-6-1,
and 67 Ib down and 123 Ib up at 1-6-1 on top chord,and 48 Ib up at 1-6-1,and 48 Ib up at 1-6-1 on bottom chord. The design/selection
of such connection device(s)is the responsibility of others.
8)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B).
9)Segn:AO020127,Date:08/28/2014
LOAD CASE(S) Standard
1)Dead+Roof Live(balanced):Lumber Increase=1.25,Plate Increase=1.25
Uniform Loads(plf) 1 �
Vert:1-2=-60,2-3=-60,4-5=-20 ■
Concentrated Loads(lb) ■
Vert:6=81(F=41,B=41)7=55(F=27,B=27)
��►`;' LICENSE'=
No.42704
STATE OF
ass .......
�oN�►t�
William M. Ranieri, P c # 42704
fuss ti55 ype Dwg No 1%
728315 HJp Diagonal Hip Girder 2 1
Job Reference(optionaj
American Buikfefs Soppy.Sanford,FL 32771 Run:7.520 s May 8 2014 Print:7.520 s Mayy 8 2014 MTek Industries,Inc. Thu Augg 28 15:29:18 2014 Pagel
ID:: ZpKbMfNUP?GwJa8Yk9zszb 3QvOYFxKPDQbVNIX1uwSkX6E3sNPQ3TJ_WhQSSyjHzl
-1-10-10 2-8-7
1-10 10 2-8-7
Scale=1:10.8
3
NAILED
NAILED
4.24 12 6
2
T1
EV
1
4. 7 4
NAILED
Q. NAILED
5
3x6 11
2-8-7
2-8-7 —
Plate Offsets(X,Y}-—[5:0-3-4,0-1-81
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.30 Vert(LL) -0.01 4-5 >999 240 MT20 244/190
TCDL 10.0 Lumber Increase 1.25 BC 0.14 Vert(TL) 0.01 4-5 >999 180
BCLL 0.0 Rep Stress Incr NO WB 0.00 Horz(TL) -0.01 3 n/a n/a Weight:12 Ib FT=20%
BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M)
LUMBER- BRACING-
TOP CHORD Structural wood sheathing directly applied or 2-8-7 oc purlins, except
TOP CHORD 2x4 SP No.2
end verticals.
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection,in accordance with Stabilizer
Installation guide — - - -
REACTIONS. (Ib/size) 5=173/0-8-2 (min.0-1-8),3=-37/Mechanical,4=-29/Mechanical
Max Horz 5=70(LC 8)
Max Uplift5=-125(LC 8),3=-37(LC 1),4=-41(LC 17)
Max Grav5=203(LC 17),3=34(LC 24),4=42(LC 24)
FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
NOTES- (9)
1)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf;BCDL=4.2psf;h=15ft;B=45ft;L=24ft;eave=4ft;Cat.11;
Exp C;Encl.,GCpi=0.18;MWFRS(directional);cantilever left and right exposed;Lumber DOL=1.60 plate grip DOL=1.60
2)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3)`This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4)Refer to girder(s)for truss to truss connections.
5)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s)3,4 except Qt=lb)
5=125.
6)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
7)"NAILED"indicates 3-10d(0.148"x3")or 2-12d(0.148"x3.25")toe-nails.For more details refer to MiTek's ST-TOENAIL Detail.
8)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B).
9)Segn:A0020125,Date:08/28/2014
LOAD CASE(S) Standard
1)Dead+Roof Live(balanced):Lumber Increase=1.25,Plate Increase=1.25
Uniform Loads(plf)
Vert:1-2=-60,2-3=-60,4-5=-20
Concentrated Loads(lb)
Vert:6=156(F=78,B=78)7=58(F=29,B=29) ■
SE
N0.42704 rr�
*•
STATE �F
%.%OF[
ti
�DNAI.ti
William M. Ranieri, P c # 42704
rues rues ype ' Dvg No 112
728315 HIXi Hip Girder 1 1
Job Reference o tional
Run:7.520 s May 8 2014 Print:7.520 s May 8 2014 MTek Industries,Inc.Thu Aug9 28 15:29:17 2014 Pagel
American Builders Soppy,Sardord,FL 32771
ID:c8A3zpKbMfNUP?GwJa8Yk9zZjN-bELeLvwh2vlkuDAKTAPDBJZ2pS1 ehciAlsytYOyjHzm
981
_1-4-0 3-0-0 �� 3�0-U
1-4-0 3-0-0
Scale=1:20.1
Special Special
4x4= Special 4x4=
3 10 4
T2
6.00 12
T1 1 T3 5 as
2
0
6 d
d
t 1
11 8 12
special 3x4= Special
special 7
9 3x8 I I
3x8 11
4 2-04 - �--0 -----
4-2-0
Plate Offsets(x.Yl— [?:0-4-8,0-1-81,[9:0-4-8,0-1-81
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.34 Vert(LL) -0.02 8 >999 240 MT20 244/190
TCDL 10.0 Lumber Increase 1.25 BC 0.18 Vert(TL) -0.04 8 >999 180
BCLL 0.0 ' Rep Stress Incr NO WB 0.03 Horz(TL) 0.00 7 n/a n/a Weight:38 Ib FT=20%
BCDL 10.0 Code FBC2010/TPI2007 (Matrix-M)
LUMBER- BRACING-
TOP CHORD Structural wood sheathing directly applied or 6
TOP CHORD 2x4 SP No.2 0-0 oc purlins, except
end verticals.
BOT CHORD 2x4 SP N0.2
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTekrecommends that Stabilizers and required cross bracing
be installed during truss erection,in accordance with Stabilizer
Installation guide. -
REACTIONS. (Ib/size) 9=387/0-3-0 (min.0-1-8),7=387/0-3-0 (min.0-1-8)
Max Horz 9=53(LC 7)
Max Uplift9=-161(LC 8),7=-161(LC 8)
Max Grav9=387(LC 1),7=396(LC 37)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 2-3=-329/163,3-10=-261/110,4-10=-261/110,4-5=-327/161,2-9=-332/168,5-7=-337/168
BOT CHORD 0-11=-132/300,8-11=-132/300,8-12=-118/300,7-12=-118/300
NOTES- (10)
1)Unbalanced roof live loads have been considered for this design.
2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf;BCDL=4.2psf;h=15ft;B=45ft;L=24ft;eave=4ft;Cat.II;
Exp C;Encl.,GCpi=0.18;MWFRS(directional);cantilever left and right exposed;Lumber DOL=1.60 plate grip DOL=1.60
3)Provide adequate drainage to prevent water ponding.
4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s)except Qt=1b)9=161,
7=161.
7)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
8)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)144 Ib down and 140 Ib up at 3-0-0,
and 72 Ib down and 59 Ib up at 4-2-0,and 152 Ib down and 125 Ib up at 5-4-1 on top chord,and 40 Ib down and 44 Ib up at 3-0-0,and
20 Ib down and 10 Ib up at 4-2-0,and 40 Ib down and 44 Ib up at 5-3-5 on bottom chord. The design/selection of such connection
device(s)is the responsibility of others.
9)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B).
10)Segn:AO020122,Date:08/2812014
LOAD CASE(S) Standard 'i'■
1)Dead+Roof Live(balanced):Lumber Increase=1.25,Plate Increase=1.25 P ....��
Uniform Loads(plf)
Vert:1-2=-60,2-3=-60,3-4=-60,4-5=-60,5-6=-60,7-9=-20 ��► ;'+LICENSE�.14
Concentrated Loads(lb) : �+
Vert:3=16(F)4=16(F)8=-4(F)10=-3(F)11=11(F)12=11(F) N0.42704 '
7l
s STATE OF
Y O■f►t�..416
William M. Ranieri, P c # 42704
Rtes ;;;����7
— Dwg No tilt
728315 HCX 1 1
Job Reference o tional)
American Builders Supply,Sanford,FL 32771 Run: .520 s May��211 4 Print:7.520 s May 8 2014 MTek Industries,Inc.Thu Aug 28 15:29:16 2014 Page 1
ID:C8A3zpKbMfN UP?GwJa8Yk9zZgN-72nG7Zv3HbAUG3c8wTu_e61 vo2jey9NOW CCKOayjHzn
_1-4-0 6-&0766-0 1"0 t-4-0
14-0 6.6-0
Scale=1:26.2
4x4=
7
8
6
6.00 12 9
5 27
26
10
4 T1 T 2 28
25 T 11
3
T 12
z q
13Li 1C
d
Bt (¢
24 23 22 21 20
19 18 17 16 15 14 S
3x8 I I
3x8 I I
13-0-0 —�
I 13.0-0 —
Plate Offsets()QZ`- [14:0-4-8,0-11-1511,[24:04-8,0-1-8] _
LOADING(psi) SPACING- 2-M CSI. DEFL. in (loc) Well Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.22 Vert(LL) -0.01 13 n/r 120 MT20 244/190
TCDL 10.0 Lumber Increase 1.25 BC 0.04 Vert(TL) -0.01 13 n/r 120
BCLL 0.0 Rep Stress Incr YES WB 0.04 Horz(TL) 0.00 14 n/a n/a Weight:74 Ib FT=20%
BCDL 10.0 Code FBC2010/TP12007 (Matrix) ---
LUMBER- BRACING-
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
TOP CHORD 2x4 SP No.2
end verticals.
BOT CHORD 2x4 SP No.2
WEBS 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. -
OTHERS 2x4 SP No.3 MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection,in accordance with Stabilizer
Installation guide. —
REACTIONS. All bearings 13-0-0.
(lb)- Max Horz 24=-95(LC 10)
Max Uplift All uplift 100 Ib or less at joint(s)20,21,22,23,18,17,16,15 except 24=-100(LC 12),14=-100(LC
12)
Max Grav All reactions 250 Ib or less at joint(s)24,14,19,20,21,22,23,18,17,16,15
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 2-24=-158/256,12-14=-158/259
NOTES- (12)
1)Unbalanced roof live loads have been considered for this design.
2)Wind:ASCE 7-10;Vult=130mph(3-second gust)Vasd=101 mph;TCDL=4.2psf;BCDL=4.2psf;h=15ft;B=45ft;L=24ft;eave=2ft;Cat.II;
Exp C;Encl.,GCpi=0.18;MWFRS(directional)and C-C Comer(3)-1-4-0 to 1-8-0,Exterior(2)1-8-0 to 6-6-0,Comer(3)6-6-0 to 9-6-0
zone;cantilever left and right exposed;C-C for members and forces&MW FRS for reactions shown;Lumber DOL=1.60 plate grip
DOL=1.60
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind(normal to the face),see Standard Industry
Gable End Details as applicable,or consult qualified building designer as per ANSI/TPI 1.
4)All plates are 2x4 MT20 unless otherwise indicated.
5)Gable requires continuous bottom chord bearing.
6)Truss to be fully sheathed from one face or securely braced against lateral movement(i.e.diagonal web).
7)Gable studs spaced at 1-4-0 oc.
8)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
10)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s)20,21,22,23,18,17
,16,15 except Qt=1b)24=100,14=100. rlti�
11)"Semi-rigid pitchbreaks including heels'Member end fixity model was used in the analysis and design of this truss.
12)Segn:AO020121,Date:08/28/2014 ■
LOADCASE(S) StandardGENSE�•;���
s N0.42704
STATE F
t4
William M. Ranieri, P c # 42704
cuss rues yPe 1309140118111
May 8 2014 M17ek In
728315
Hal Common 1 1
Job Reference�ptiona�
American Buildefs uySarord,FL 32771 Run: ID?c8A3z0 s pKbMfNUP?Gra:wJ U ZU 14 .3 8Yk9zZjjN frEuwEvRX121ewlyMINI6uUgWeJVDigtlYTmU7y28 15:29:15 2014 jHHzo
411-8 9-3-8
— - - - -5
411 8
Scale=1:21.6
4x4=
2
6.00 12 9
8
T2 10
7 T1 3x4 11
W1 3
1 a
131
5 4
2x4 11 3x4 11
6
3x8 11
411-8 9-3-8
F 411-8 4-"
Plate Offsets(X Y� [6 0-4-8,0-"]
--
LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25 TC 0.45 Vert(LL) 0.03 5 >999 240 MT20 244/190
TCDL 10.0 Lumber Increase 1.25 BC 0.29 Vert(TL) -0.07 5-6 >999 180
Horz TL 0.01 4 n/a n/a
BCLL 0.0 Rep Stress Incr YES WB 0.06 ( ) Weight:35 Ib FT=20%
BCDL 10.0 Code FBC2010/TPl2007 (Matrix-M) _ - -
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except
end verticals.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection,in accordance with Stabilizer
In.
guide. -
REACTIONS. (Ib/size) 6=360/Mechanical,4=360/Mechanical
Max Horz 6=55(LC 11)
Max Uplift6=-83(LC 12),4=-85(LC 12)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown.
TOP CHORD 1-7=-375/169,7-8=-304/171,2-8=-294/181,2-9=-290/191,9-10=-308/183,3-10=-371/180,
3-4=-284/190,1-6=-294/197
BOT CHORD 5-6=-101/272,4-5=-101/272
NOTES- (8)
1)Unbalanced roof live loads have been considered for this design.
2)Wind:
:ASCEEncl., -10;GCpiV .l1 l MW FRS3(decond gust)ndasd=101 mph;2)0-1-12?0 3-1B12D In erior(1)3-1512 o 4-11-8,8,Exterior(2)4--11-8 toExp l
7-11-8 zone;cantilever left and right exposed;C-C for members and forces 8 MWFRS for reactions shown;Lumber DOL=1.60 plate grip
DOL=1.60
3)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4)`This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
5)Refer to girder(s)for truss to truss connections.
6)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 83 Ib uplift at joint 6 and 85 Ib uplift at joint 4-
7)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
8)Segn:A0020118,Date:08/28/2014
LOAD CASE(S) Standard
�M All.
LICENSE6•;���
No.42704
z STATE 8F
' 'o �'•. ti
William M. Ranieri, P c # 42704
cuss
77 `8
728315 FiA6 1 1 Job Refereence optional) _ 28 15:29:14 2014 Pag
American Builders Supply,Samford,FL 32777 Run.ID cB�zpKbMtNUP 8201 ,?G2014 PnntwJa8Yk9z2llN-BfgVjuupm wA 8 2014 M,Tek mSIo2rWZhxV1 ExLUCZj3ujDyhyjHzp
1248-8 18-9-8
68-86-0-06-1-0
68-8
Scale=1:31.1
4x8= 4x4=
3 16 17 t8 4
T2
6.00 12
19
Y
15 1 20 N
14 3x6-
4x4 N 5
2
N
1
B1
g 7 6
9 2x4 11
2x4 II 3x4_ 3x12—
3x8 11
18-9-8
6-8-8 128 8 6-1-0 —�
688 6-0-0
Plate Offsets(X Y)— [1.0-2-12 0-1-9] [3:0-5-4,13-2-0]
LOADING(psf) SPACING- 2-0-0T
SI. DEFL. in (loc) I/defl Ud PLATES GRIP
TCLL 20.0 Plates Increase 1.25C 0.50 Vert(LL) -0.04 7-9 >999 240 MT20 244/190
TCDL 10.0 Lumber Increase 1.25C 0.41 Vert(TL) 0.10 6-7 >999 180
BCLL 0.0 ' Rep Stress Incr YESWB 0.25 Horz(TL) 0.02 6 n/a n/a Weight:92 Ib FT=20%
BCDL 10.0 Code FBC2010/TPI2007Matrix-M) —
LUMBER- BRACING-
TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 5-1-1 oc purlins, except
end verticals.
BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
SLIDER Left 2x6 SP No.2 1-6-0 MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection,in accordance with Stabilizer
Installation guide. _ — —
REACTIONS. (Ib/size) 1=746/0-6-0 (min.0-1-8),6=746/Mechanical
Max Horz 1=78(LC 11)
Max Upliftl=-173(LC 12),6=-174(LC 12)
FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown.
TOP CHORD 1-2=-464/0,2-14=-1044/370,14-15=-991/376,3-15=-964/390,3-16=-822/381,
16-17=-822/381,17-18=-8221381,4-18=-822/381,4-19=-917/357,19-20=-918/346,
5-20=-998/341,5-6=-687/296
BOT CHORD 1-9=-291/861,8-9=-278/866,7-8=-278/866
WEBS 5-7=-150/661
NOTES- (9)
1)Unbalanced roof live loads have been considered for this design.
2)Exlp CAE cl.,GCpi=O.118;MWFRS(directional)al)gust)cond daC-Cl01 mph;
Exterior(2)0-0-0 to 3-0-OCnnterio(P)3-0-0 to 6-8-8,Exterior(2)6-8-8 to 6-11116,
Interior(1)16-11-6 to 18-7-12 zone;cantilever left and right exposed;C-C for members and forces&MWFRS for reactions shown;
Lumber DOL=1.60 plate grip DOL=1.60
3)Provide adequate drainage to prevent water ponding.
4)This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5)'This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
6)Refer to girder(s)for truss to truss connections.
7)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 173 lb uplift at joint 1 and 174 Ib uplift at joint
6.
8)"Semi-rigid pitchbreaks including heels"Member end fixity model was used in the analysis and design of this truss.
9)Segn:A0020117,Date:08/28/2014 �aM�
LOAD CASE(S) Standard ••'•
LICENSE
s N0.42704
z STATE OF
D m
% 4 ss.......
William M. Ranieri, P c # 42704