80 Beach Cottage Ln 2014 HVAC CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Application Number . . . . . 14-00001S15 Date 9/15/14 Property Address . . . . . . 80 BEACH COTTAGE LN Application type description MECHANICAL HVAC ONLY Property Zoning . . . . . . . RES GEN MF DISTRICT Application valuation . . . . 0 ---------------------------------------------------------------------------- Application desc 1 cu 1 ahu ---------------------------------------------------------------------------- Owner Contractor ------------------------ ------------------------ KING ET AL, HALL KIRSTEN G B & G REFRIGERATION 80 BEACH COTTAGE LN 3230 KLINE RD. ATLANTIC BEACH FL 32233 JACKSONVILLE FL 32246 (904) 620-0081 ----------------------------------------------------------------------------- Permit MECHANICAL HVAC PERMIT Additional desc . . Permit Fee . . . . 99 . 00 Plan Check Fee . 00 Issue Date . . . . Valuation . . . . 0 Expiration Date . . 3/14/15 ---------------------------------------------------------------------------- Special Notes and Comments STICKER FOR OVERCURRENT PROTECTION MUST BE ON A/C EQUIPMENT PRIOR TO INSPECTION. FAILURE TO COMPLY WILL RESULT IN A FAILED INSPECTION AND REINSPECT FEES . NO EXCEPTIONS . ---------------------------------------------------------------------------- Other Fees . . . . . . . . . STATE MECH DCA SURCHARGE 2 . 00 STATE MECH DBPR SURCHARGE 2 . 00 ---------------------------------------------------------------------------- Fee summary Charged Paid Credited Due ----------------- ---------- ---------- ---------- ---------- Permit Fee Total 99 . 00 99 . 00 . 00 . 00 Plan Check Total . 00 . 00 . 00 . 00 Other Fee Total 4 . 00 4 . 00 . 00 . 00 Grand Total 103 . 00 103 . 00 . 00 . 00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Semino _!22_��d Atlantic Beach, FL 32233 Ph(904)247-5826 Fax (904) 247-5845 JOB ADDRESS: %L) UaQ� Vd, PERMIT PROJECT VALUE $ 'uw IOU ARI# REQUIRED Air Handling Equipment Only /`Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit — — Heat: Unit Quantity BTU's Per Unit Seer Ratin Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit 13 Heat: Unit Quantity BTU's Per Unit Seer Rating 12> Duct Systems: Total CFM REQUIRED FIRE PREVENTION 4�QA Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name V'k no, "n I skn G Phorke Number _Q GA00 I Mechanical Company QTV�) A,�- —Office Phone (VW.Ll'ft.� Fax Lo,-0 qg(S VL'k_y� Co. Address:3�& F City State zip -�q(D License Holder(Print), S Certification/Registration# Notan' ad 5�qwa*#_t-�ietyft STEPHANEY STRAHAN `1' "1 state ot F8 e nine this dz�ro 2Q/ Notary Public t 5 r my comm.Expires Apr 12,2015 M ur fn OF f commission# EE 720�gjg c of Notary Public Project Summary Job: Kinghall,Justin-4842 wrightsoft Date: Sep 09,2014 Entire House By: B & G Refrigeration Co 3230 Kline Rd,Jax, Fl 32246 Phone 904-620-0081 Fax:904-620-9815 Email jean ne(gbgref rigerat ion.com Web:www.bgrefrigeration.com License:CAC1813635 Project Information For: Kinghall, Justin - 4842 80 Beach Cottage Lane,Atlantic Beach, FI 32233 Notes: Design Information Weather: Jacksonville, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 'F Outside db 93 'F Inside db 70 'F Inside db 75 'F Design TD 38 'F Design TD 18 'F Daily range M Relative humidity 50 % Moisture difference 52 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 32880 Btuh Structure 25794 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 32880 Btuh Use manufacturer's data n Rate/swing multiplier &98 Infiltration Equipment sensible load 25226 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3736 Btuh Ducts 0 Btuh Heating Coolin Central vent (0 cfm) 0 Btuh Area (ft') 6009 600? Equipment latent load 3736 Btuh Volume(ft') 42063 42063 Air changes/hour 0.28 0.15 Equipment total load 28962 Btuh Equiv.AVF (cfm) 196 105 Req. total capacity at 0.70 SHR 3.0 ton Heating Equipment Summary Cooling Equipment Summary Make Bryant Make Bryant Trade Bryant Trade Bryant Model 213C NA036000 Cond 213CNA036000 AHRI ref 3700149 Coil FBCNF036TOO AHRI ref 3700149 Efficiency 0 HSPF Efficiency 13 SEER Heating input Sensible cooling 0 Btuh Heating output 0 Btuh @ 47'F Latent cooling 0 Btuh Temperature rise 0 'F Total cooling 0 Btuh Actual air flow 1174 cfm Actual air flow 1174 cfm Air flow factor 0.036 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.87 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2014-Sep-09 15:56:09 + wrightsoft Right-Suite@ Universal 201212.0.10RSU15229 Page I ACCN Projectl.rup Calc=MJ8 Front Door faces N Job: Kinghall,Justin-4842 Load Short Form Date: Sep 09,2014 + wrightsoft' Entire House By: B & G Refrigeration Co 3230 Kline Rd,Jax,Fl 32246 Phone:904-620-0081 Fax:904-620-9815 Emaiii jeanne@bgref rigerat ion,corn Webi www,bgrefrigeration,com License:CAC1813635 For: Kinghall, Justin - 4842 80 Beach Cottage Lane,Atlantic Beach, FI 32233 Ht9 Cig Infiltration Simplified Outside db ('F) 32 93 Method Average Inside db ('F) 70 75 Construction quality 0 Design TD ('F) 38 18 Fireplaces Daily range - M Inside humidity 30 50 Moisture difference(gr/lb) 12 52 HEATING EQUIPMENT COOLING EQUIPMENT Make Bryant Make Bryant Trade Bryant Trade Bryant Model 213CNA036000 Cond 213CNA036000 AHRI ref 3700149 Coil FBCNF036TOO AHRI ref 3700149 13 SEER Eff iciency 0 HSPF Efficiency 0 Btuh Heating input Sensible cooling 0 Btuh Heating output 0 Btuh @ 47'F Latent cooling 0 Btuh Temperature rise 0 oF Total cooling 1174 cfm Actual air flow 1174 cfm Actual air flow 0.046 cfm/Btuh Air flow factor 0.036 cfm/Btuh Air flow factor 0 in H20 0 in H20 Static pressure Static pressure Load sensible heat ratio 0.87 Space thermostat ROOM NAME Area Htg load CIg load Htg AVF CIgAVF (ft2) (Btuh) (Btuh) (cfm) (cfm) 4800 26809 20930 957 952 Rooml 1209 6070 4864 217 221 Room2 6009 32880 25794 1174 1174 Entire House 0 0 Other equip loads 25226 Equip. @ 0.98 RSIVI 3736 Latent cooling TOTALS 6009 1 32880 28962 1174 1174 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2014-sep-09 15:56:09 + wrightSOft Right-Suite(&universal 2012 12.0,10 RSU15229 Page 1 Projectl rup Calc=MJS Front Door faces� N Job: Kinghall,Justin-4842 + wrightsoft Building Analysis Date: Sep 09,2014 Entire House By: B & G Refrigeration Co 3230 Kline Rd,Jax,Fl 32246 Phone:904-620-0081 Fax:904�620-9815 Email jeanne@bgrefrigeration.com Web:www.bgrefrigeration.com License:CAC1813635 For: Kinghall, Justin - 4842 80 Beach Cottage Lane,Atlantic Beach, FI 32233 Design Conditions Location: Indoor: Heating Cooling Jacksonville, FL, US Indoor temperature(*F) 70 75 Elevation: 30 ft Design TD ('F) 38 18 Latitude: 31 oN Relative humidity (%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 11.7 52.3 Dry bulb ('F) 32 93 Infiltration: Simplified Daily range�F) - is ( M Method Wet bulb (' - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Heatinci Component Btuh % of load Walls 30 8501 25.9 Glazing 21.8 3578 10.9 Doors 14.9 1773 5.4 Ceilings 1.2 7345 22.3 Floors 0.6 3443 10.5 Infiltration 3.4 8239 25.1 Ducts 0 0 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 Total 1 328801 100.01 Cooling Component Btuh/ft2— Btuh % of load Walls 0.9 2706 10.5 Glazing 56.7 9315 36.1 Doors 11.8 1399 5.4 Ceilings 1.7 10316 4&0 Floors 0 0 0 Infiltration 0.8 2057 8.0 Ducts 0 0 Ventilation 0 0 Internal gains 0 0 Blower 0 0 Adjustments Total 01 100.0 25794 Latent Cooling Load 3736 Btuh Overall U-value= 0.039 Btuh/ftl-'F WARNING: window to floor area ratio 2.7% - less than 5%. 2014-Sep-09 15:56:09 + wrightsoft Right-Suite(D Universal 2012 12.0.10 RSU15229 Page I Projectl,rup Calc=MJ8 Front Door faces: N Job: Kinghall,Justin-4842 + wrightsoft, Component Constructions Date: Sep 09,2014 Entire House By: B & G Refrigeration Co 3230 Kline Rd,Jax,Ft 32246 Phone:90"20-0081 Fax:904-620-9815 Email jeanne@bgref rigerat ion.com Web:www bgref rigeration.com License:CAC 1813635 Project Information For: Kinghall, Justin - 4842 80 Beach Cottage Lane,Atlantic Beach, FI 32233 Design Conditions Location: Indoor: Heating Cooling Jacksonville, FL, US Indoor temperature(T) 70 75 Elevation- 30 ft Design TD (T) 38 18 Latitude: 31'N Relative humidity 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 11.7 52.3 Dry bulb (T) 32 93 Infiltration: Daily range(T) - 18 M Method Simplified Wet bulb(T) - 77 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Or Area Ll-value Insul R Htg HTM Loss Cig HTM Gain Construction descriptions ft2 Btuh/W-T ft�-'F/Btuh BtuhV Btu h Btuh/ft2 Btu h Walls 2.95 1345 0.92 420 15B-10sfc-2:Bg wall,light dry soil,concrete wall,r-10 ins,8"thk n 456 0.061 10.0 e 648 0.061 10'0 2.96 1920 0.94 610 S 756 0.061 10.0 2.97 2244 0.95 717 w 1007 0.061 10.0 2.97 2992 0.95 960 all 2867 0.061 10.0 2.97 8501 0.94 2706 Partitions (none) Windows 1D-c2ow:2 glazing,clr outr,air gas,wd frm mat,clr innr, 1/4"gap, n 28 0.570 0 21.8 610 21.8 609 1/4"thk e 72 0.570 0 21.8 1568 63.9 4598 w 64 0.570 0 21.8 1401 63.9 4108 all 164 0.570 0 21.8 3578 56.7 9315 Doors I I DO:Door,wd s c type n 56 0.390 0 14.9 834 11.8 658 s 63 0.390 0 14.9 939 11.8 741 all 119 0.390 0 14.9 1773 11.8 1399 Ceilings 16B-30ad:Attic ceiling,asphalt shingles roof mat,r-20 roof ins,r-30 6009 0.032 30.0 1.22 7345 1.72 10316 cell ins Floors 218-28t:Bg floor,light dry soil,prm int ins cov,6.5'depth,r-3 ins, 6009 0.015 3.0 0.57 3443 0 0 tile flr fnsh 2014-Sep-09 15:56:09 + wrightsoft Right-Suite(D universal 2012 12.0.10 RSU15229 Page 1 ACAZ�k Projecti.rup Calc=NIJ8 Front Door faces: N AED Assessment Job: Kinghall,Justin-4842 + wrightsoft, Date: Sep 09,2014 Entire House By: B & G Refrigeration Co 3230 Kline Rd,Jax,F1 32246 Phone:904-620-0081 Fax:904-620-9815 Email,jeanne@bgref rigerat ion com Web:www.bgrefrigeration com License:CAC1813635 Project Information For: Kinghall, Justin - 4842 80 Beach Cottage Lane, Atlantic Beach, Fl 32233 Design Conditions Location: Indoor: Heating Cooling Jacksonville, FL, US Indoor temperature(OF) 70 75 Elevation: 30 ft Design TD (T) 38 18 Latitude: 31'N Relative humidity 30 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 11.7 52.3 Dry bulb (OF) 32 93 Infiltration: Daily range(OF) - 18 ( M Wet bulb (OF) - 77 Wind speed (mph) 15.0 7.5 Test for Adequate Exposure Diversity Hourly Glazing Load 11,000-- 10,000-- 9,000-- 8,000-- ... ............................ 7,000- 6,000-- 5,000-- 4,000-- 3,000-- 2,000-- 1,000-- 0 i i i i 8 9 10 11 12 13 14 15 16 17 18 19 20 Hou of Day 1= Hourty I. AED 1-1 Maximum hourly glazing load exceeds average by 20.9%. House has adequate exposure diversity (AED), based on AE D limit of 30%. AED excursion: 0 Btuh 2014-Sep-09 15�56:09 'Zti + wrightsoft Right-SuiteS Universal 2012 12.0.10 RSU15229 Pagel Acc-�' Projectl.rup Calc=MJ8 Front Door faces: N + wrightsoft Right-M)Worksheet Job: Kinghall,Justin-4842 Entire House Date: Sep 09,2014 By: B & G Refrigeration Co 3230 Kline Rd,Jax,F1 32246 Phone:904-620-0081 Fax 904-620-9815 Email.jearine@bgref rigerat ion,com Web:www bgrefrigeration com License,CAC1813635 1 Room name Entire House Rooml 2 Exposed wall 350�O ft 280.0 ft 3 Room height 9.0 ft 9.0 ft heaVcool 4 Room dimensions 60.0 x 80,0 ft 5 Room area 6009.0 ft2 4800.0 ft2 Ty Construction U-value Or HTM Area (ft� Load Area (ft2) Load number (Btuh/ft'-'F) (Btuh/ft2) or perimeter (ft) (13tuh) or perimeter (ft) (13tuh) Heat I Cool G ross N/P/S Heat Cool i Gross N/P/S Heat Cool 6 158-1()Sfc-2 OM3 n 2,95 &92 540 456 1345 420 540 456 1345 420 1 D-c2ow &570 n 2177 21.76 28 0 610 609 28 0 610 609 11DO 0.390 n 14.90 11.76 56 56 834 658 56 56 834 658 W 15B-10sfc-2 0.083 e 2.96 0,94 720 648 1920 610 720 648 1920 610 11 L-G 1D-c2. 0.570 e 21.77 63.86 72 0 1568 4598 72 0 1568 4598 513-10sfc-2 0,083 s 2.97 0.95 819 756 2244 717 540 477 1412 446 t—D 111DO 0390 s 14.90 11.76 63 63 939 741 63 63 939 741 5B-10sfc-2 0.083 W 2.97 0.95 1071 1007 2992 960 720 676 2008 644 t---G 11D-c2ow O�570 w 21.77 63.86 64 0 1401 4108 44 0 965 2831 C 1613-30ad 0.032 1.22 1.72 6009 6009 7345 10316 4800 4800 5868 8241 F 2113-28t 0.015 0.57 0,00 6009 6009 3443 0 4800 4800 2750 0 6 c)AED excursion 0 -512 Envelope loss/gain 24640 23737 20218 19285 12 a) Infiltration 8239 2057 6591 1645 b) Room ventilation 0 0 0 0 131 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 1 0 Subtotal(lines 6 to 13) 328801 25794 )30 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 0 0 0 0 Redistribution 26809 20930 14 Subtotal 32880 25794 1 5 Duct loads 0%. 0% 0 0 -0% 0% 0 01 IT-- T otal room load 32880 25794 26809 20930 11741 11741 957 952 Air required(cfm) I I -- I I- Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. +[11- wrightsoft 2014-Sep,09 15:56 09 Right-SuiteS Universal 2012 12.0.10 RSU15229 Page 1 Projectl.rup Calc=MJ8 Front Door faces N + wrightsoft Right-M) Worksheet Job: Kinghall,Justin-4842 Entire House Date: Sep 09,2014 By: B & G Refrigeration Co 3230 Kline Rd,Jax, Fl 32246 Phone:904-620-0081 Fax:904-620-9815 Email jeanne@bgrefrigeration.com Web:www.bgrefrigeration.com License:CAC1813635 1 Room name Room2 2 Exposed wall 70.0 ft 3 Room height 9�0 ft heat/cool 4 Room dimensions 31.0 x 39.0 ft 5 Room area 1209.0 ft2 Ty Construction U-value 0 r HTM Area yt� Load Area Load number (Btuh/ft2_-F) (Btuh/ftj or perimeter (ft) (Btuh) or perimeter Heat I cool G ross N/P/S Heat cool Gross NIP/S Heat cool 6 115B-10sfc-2 0.083 n 2.95 0.92 0 0 0 0 D-c2ow, 0.570 n 21.77 21,76 0 0 0 0 11DO 0.390 n 14.90 11 76 0 0 0 0 W 15B-10sfc-2 0.083 e 2.96 0.94 0 0 0 0 1 L--G 1 D-c2ow 0.570 e 21.77 63.86 0 0 0 0 5B-10sfc-2 0.083 s 2.97 0.95 279 279 832 271 t—D 111DO 0,390 s 14.90 11.76 0 0 0 0 5B-10sfc-2 0.083 w 2.97 0.95 351 331 984 316 t--,G 11D-c2ow 0570 w 21.77 63.86 20 0 435 1277 C 16B-30ad 0.032 1.22 1.72 1209 1209 1478 2076 F 2113-28t 0.015 0.57 0.00 1209 1209 693 0 6 c)AED excursion 512 Envelope loss/gain 4423 4452 12 a) Infiltration 1648 411 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appfiances/other 0 Subtotal(lines 6 to 13) 6070 4864 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 6070 4864 14 S ubtotal 15 Duct loads -0% 0% 0 0 ad 6070 4864 M) 2171 2211 1 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2014-Sep-09 15:56 09 vvriighltsc�ft Right-SufteO Universal 2012 12.0.10 RSU15229 Page 2 Projecti.rup Calc=MJ8 Front Door faces� N Loads for Multiple Orientations Job: Kinghall,Justin-4842 + wrightsoft, Date: Sep 09,2014 Entire House By: B & G Refrigeration Co 3230 Kline Rd,Jax, Fl 32246 Phone:904-620-0081 Fax:904-620-9815 Ernail�jeanne@bgref rigerat ion.corn Web:www.bgrefrigeration.com License: CAC1813635 Project Information For.- Kinghall, Justin - 4842 80 Beach Cottage Lane,Atlantic Beach, FI 32233 Design Conditions Location: Indoor: Heating Cooling Jacksonville, FL, US Indoor temperature (OF) 70 75 Elevation: 30 ft Design TD (OF) 38 18 Latitude: 31 ON Relative humidity 30 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 11.7 52.3 Dry bulb (OF) 32 93 Infiltration: Daily range (OF) - 18 ( M Wet bulb (OF) - 77 Wind speed (mph) 15.0 7.5 Front Door North Northeast East Southeast South Southwest West Northwest Sensible Load (Btuh) 25226 23938 21074 24009 25346 23990 21068 24180 Latent Load (Btuh) 3736 3736 3736 3736 3736 3736 3736 3736 Total Load (Btuh) 28962 27674 24810 27745 290821 27725 24804 27916 Heating AVF (cfm) 1174 1114 981 1117 1179 1116 980 1125 Cooling AVF (cfm) 1 1174 1 1114 1 981 1117 1 1179 1 1116 1 980 1 1125 Building Orientation Cooling Load 30000-- 25000-- co 20000-- 0 _J CM .s 15000-- 0 0 0 Fa 10000-- '5 5000-- N NE E SE S Sw W NW Direction Front Door faces Current Orientation'. Front Door faces North Highest Cooling Load: Front Door faces South Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2014-Sep-09 15:56 10 + wrightsoft Right-Suite(&Universal 2012 lZ0.10 RSU15229 Page 1 Project 1.rup Calc=MJ8 Front Door faces: N