1665 Selva marina Dr 2014 bath remodel CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
MECHANICAL HVAC PERMITATLANTIC BEACH, FL 32233
U CALL BY 4PM FOR NEXT DAY INWff"(3A7PW*iE LINE 247-5814
JOB IN M
Job ID: 14-00001030
Job Type: RESIDENTIAL ALTERATION
Description: bath remodel
Estimated Value: $42,000.00
Issue Date: 9/23/2014
Expiration Date: 3/22/2015
PROPERTY ADDRESS:
Address: 1665 SELVA MARINA DR
RE Number: 171996-0000
PROPERTY OWNER:
Name: HULIHAN, CARMEN S
Address:
GENERAL CONTRACTOR INFORMATION:
Name: CLADDAGH CONSTRUCTORS, INC.
Address:
Phone: - -
PERMIT INFORMATION: Sticker for overcurrent protection must be on A/C equipment prior to
inspection. Failure to comply will result in a failed inspection and reinspect fees. No
exceptions.
FEES:
PERMIT FEES $260.00
STATE DCA SURCHARGE $3.90
STATE DBPR SURCHARGE $3.90
PLAN CHECK FEES $130.00
PERMIT FEES $104.00
STATE PLBG DCA SURCHARGE $2.00
STATE PLBG DBPR SURCHARGE $2.00
PERMIT FEES $59.80
STATE ELEC DCA SURCHARGE $2.00
STATE ELEC DBPR SURCHARGE $2.00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
AC e rige $12.00 ATLANTIC BEACH,FL 32233
INSPECTION PHONE LINE 247-5814
State urcharge $2.00
State Mech DCA Surcharge $2.00
Trade Permit Base Fee $55.00
Total Payments: $71.00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach,FL 32233
Ph(904)247-5826 Fax(904)247-5845 PERMIT# 1 t�'� 0
JOB ADDRESS: lee4��
PROJECT "LUE $ ARI# 2-3 —REQUIRED
Air Handling Equipment Only _yAir Handling Unit & Condenser Condenser Only
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit — /
Heat: Unit Quantity BTU's Per Unit �OQ-442.*e Seer Rating_ / 7.
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating REQUIRED
Duct Systems: Total CFM
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
# Vented Wall Furnaces Refrigerator Condenser BTU's
4 Water Heaters Solar Collection Systems
Tanks(gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned fox-six months.I hereby certify that 1 have read
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name e�o�j&c4� Phone Number
Mechanical Company Office Phone-9-
city State Zip
Co. Address:
ton
License Holder(Print): State Certification/Registrati
Notarized Signature of License Holder
KAREN E.PANTFOEDER Before me this day of �2o_j 4-
1vNOTARY�UBLIC
STATE OF FLORIDA c
Comm#EE064448 Signature of Notary Public
ir Expires 3/4015
SUBMITTAL EH035CAV Slim Duct 12,000 Btu/h Heat Pump
Job Name Location
Purchaser Engineer
Submitted to Reference proval - Construction
Unit Designation Schedule#
Specifications ---T
General I EK035CAV
Nom Cooling Ca aci ( /h) 12,000
SEER 17.8
,Cool Capad Ran e(Btu/h 3.300 to 14,306 49:TF*
NomHeatin Ca aci (Btu/h 13,600
HSPF 9.2 MIT#
ik
E
00 ER
I Ca act Ran e(Blulh
Heatin COP 3.4
HeatCapacityRan e Btu/h 3,100 to 18,006 ILI
Refiri erant T e R41 OA 1.11 fill;
De-Hum Pints/Hr) 5.6
Power Voltage 208/230v-1 Ph Construction
S, -�z
Breaker WSize 20A Indoor Unit shall be made from galvanized steel
RLA Cooling/Heating(Amps)., 5.5/5.4A The Outdoor unit shall be galvanized steel with a
Controls Wired baked on powder coated finish for durability
Indoor Unit EH035CAV
Airflows H-M-L(CFM) 370/320/265 Heat Exchangers
1Max External Static("WC) 0.125" The heat exchangers shall be mechanically bonded fin
Noise Level High(Db) 40 to copper tube.
kidth(Inches) 35 7/'16"
Height(inches) 7 13/16" Refrigerant System
!Total Depth(Inches 23 5/8" Compressors shall be a hermetically sealed DC
Wei ht(lbs 57 Inverter drive rotary type
St ly Duct Connection 6"x 33 3/4" Refrigerant shall be R41 OA.
2utdoor Unit UH035CAV Refrigerant flow shall be controlled by Electronic
Outdoor Noise Level Db 53 Expansion Valve
Width Inches 31 1/8"
Height Inches) 21 7/8" IndoorFan
Total De th Inches
11 1/4" Indoor Fan are twin backward curved centrifugal
Weight(Ibs) 74 type with a single fan motor
Line Sets Units are capable of acting against 0.125"ESP
Size 1/4"&3/8"� The outdoor unit fan shall be a propeller type
Max Line Set Le—ngth—inc 65ft 1
Max Vertical Separation of 23ft Controls
Charged with R41 OA for 50ft The unit shall be operated via a wired remote control
Addl R41 OA charge required 0.15 oz/ft over 50ft Control signal shall be a DDC type signal
Certifications Controls shall integrate with a BMS system
Safety UL&Ulc Control wiring shall require 16AWG shielded wire
Performance ARI Certified Unit operating range shall be
,ARI Certification Reference# 1362349 Cooling 23 DegF to 115 DegF
Warranty 5 Years Compressor Heating 5 DegF to 70 DegF
3 Years Parts i
120 Days Rd 4!�� Air Filtration
optms 1 25 or 50ft Line Sets As standard the unit has no air filtration
lmp�
s
condensate Pumps Filtration is field installed,pressure drop across the
Condenser Brackets filter must be factored into the total ESP applied
Quietside 8750 Pioneer Blvd,Santa Fe Springs CA 90670 Tel:562 699 6066,Fax:562 699 4351
6 Pine Hill Dr,Carlisle PA 17013 Tel:717 243 2535,Fax:717 243 7917
www.guietside.com
Due to Samsung's policy of on-going product development specifications are subject to change vothout notice SAM-SBEHO35-10-07