Loading...
1665 Selva marina Dr 2014 bath remodel CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD MECHANICAL HVAC PERMITATLANTIC BEACH, FL 32233 U CALL BY 4PM FOR NEXT DAY INWff"(3A7PW*iE LINE 247-5814 JOB IN M Job ID: 14-00001030 Job Type: RESIDENTIAL ALTERATION Description: bath remodel Estimated Value: $42,000.00 Issue Date: 9/23/2014 Expiration Date: 3/22/2015 PROPERTY ADDRESS: Address: 1665 SELVA MARINA DR RE Number: 171996-0000 PROPERTY OWNER: Name: HULIHAN, CARMEN S Address: GENERAL CONTRACTOR INFORMATION: Name: CLADDAGH CONSTRUCTORS, INC. Address: Phone: - - PERMIT INFORMATION: Sticker for overcurrent protection must be on A/C equipment prior to inspection. Failure to comply will result in a failed inspection and reinspect fees. No exceptions. FEES: PERMIT FEES $260.00 STATE DCA SURCHARGE $3.90 STATE DBPR SURCHARGE $3.90 PLAN CHECK FEES $130.00 PERMIT FEES $104.00 STATE PLBG DCA SURCHARGE $2.00 STATE PLBG DBPR SURCHARGE $2.00 PERMIT FEES $59.80 STATE ELEC DCA SURCHARGE $2.00 STATE ELEC DBPR SURCHARGE $2.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD AC e rige $12.00 ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 State urcharge $2.00 State Mech DCA Surcharge $2.00 Trade Permit Base Fee $55.00 Total Payments: $71.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach,FL 32233 Ph(904)247-5826 Fax(904)247-5845 PERMIT# 1 t�'� 0 JOB ADDRESS: lee4�� PROJECT "LUE $ ARI# 2-3 —REQUIRED Air Handling Equipment Only _yAir Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit — / Heat: Unit Quantity BTU's Per Unit �OQ-442.*e Seer Rating_ / 7. Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating REQUIRED Duct Systems: Total CFM FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's 4 Water Heaters Solar Collection Systems Tanks(gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned fox-six months.I hereby certify that 1 have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name e�o�j&c4� Phone Number Mechanical Company Office Phone-9- city State Zip Co. Address: ton License Holder(Print): State Certification/Registrati Notarized Signature of License Holder KAREN E.PANTFOEDER Before me this day of �2o_j 4- 1vNOTARY�UBLIC STATE OF FLORIDA c Comm#EE064448 Signature of Notary Public ir Expires 3/4015 SUBMITTAL EH035CAV Slim Duct 12,000 Btu/h Heat Pump Job Name Location Purchaser Engineer Submitted to Reference proval - Construction Unit Designation Schedule# Specifications ---T General I EK035CAV Nom Cooling Ca aci ( /h) 12,000 SEER 17.8 ,Cool Capad Ran e(Btu/h 3.300 to 14,306 49:TF* NomHeatin Ca aci (Btu/h 13,600 HSPF 9.2 MIT# ik E 00 ER I Ca act Ran e(Blulh Heatin COP 3.4 HeatCapacityRan e Btu/h 3,100 to 18,006 ILI Refiri erant T e R41 OA 1.11 fill; De-Hum Pints/Hr) 5.6 Power Voltage 208/230v-1 Ph Construction S, -�z Breaker WSize 20A Indoor Unit shall be made from galvanized steel RLA Cooling/Heating(Amps)., 5.5/5.4A The Outdoor unit shall be galvanized steel with a Controls Wired baked on powder coated finish for durability Indoor Unit EH035CAV Airflows H-M-L(CFM) 370/320/265 Heat Exchangers 1Max External Static("WC) 0.125" The heat exchangers shall be mechanically bonded fin Noise Level High(Db) 40 to copper tube. kidth(Inches) 35 7/'16" Height(inches) 7 13/16" Refrigerant System !Total Depth(Inches 23 5/8" Compressors shall be a hermetically sealed DC Wei ht(lbs 57 Inverter drive rotary type St ly Duct Connection 6"x 33 3/4" Refrigerant shall be R41 OA. 2utdoor Unit UH035CAV Refrigerant flow shall be controlled by Electronic Outdoor Noise Level Db 53 Expansion Valve Width Inches 31 1/8" Height Inches) 21 7/8" IndoorFan Total De th Inches 11 1/4" Indoor Fan are twin backward curved centrifugal Weight(Ibs) 74 type with a single fan motor Line Sets Units are capable of acting against 0.125"ESP Size 1/4"&3/8"� The outdoor unit fan shall be a propeller type Max Line Set Le—ngth—inc 65ft 1 Max Vertical Separation of 23ft Controls Charged with R41 OA for 50ft The unit shall be operated via a wired remote control Addl R41 OA charge required 0.15 oz/ft over 50ft Control signal shall be a DDC type signal Certifications Controls shall integrate with a BMS system Safety UL&Ulc Control wiring shall require 16AWG shielded wire Performance ARI Certified Unit operating range shall be ,ARI Certification Reference# 1362349 Cooling 23 DegF to 115 DegF Warranty 5 Years Compressor Heating 5 DegF to 70 DegF 3 Years Parts i 120 Days Rd 4!�� Air Filtration optms 1 25 or 50ft Line Sets As standard the unit has no air filtration lmp� s condensate Pumps Filtration is field installed,pressure drop across the Condenser Brackets filter must be factored into the total ESP applied Quietside 8750 Pioneer Blvd,Santa Fe Springs CA 90670 Tel:562 699 6066,Fax:562 699 4351 6 Pine Hill Dr,Carlisle PA 17013 Tel:717 243 2535,Fax:717 243 7917 www.guietside.com Due to Samsung's policy of on-going product development specifications are subject to change vothout notice SAM-SBEHO35-10-07