172 6TH ST 2014 HVAC 1.ss\ CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
MECHANICAL HVAC PERMITATLANTIC BEACH, FL 32233
CALL BY 4PM FOR NEXT DAY INFR§FW"(31k7P1M&E LINE 247-5814
JOB IN M
Job ID: 14-MECH-1 57
Job Type: MECHANICAL HVAC ONLY
Description: 3 TONS 36K BTUS
Estimated Value:
Issue Date: 10/8/2014
Expiration Date: 4/6/2015
PROPERTY ADDRESS:
Address: 172 6TH ST
RE Number: 170150-0000
PROPERTY OWNER:
Name: HOOTEN 11, M EARL B
Address: 172 6TH ST
GENERAL CONTRACTOR INFORMATION:
Name: DONOVAN HEATING & AIR
Address:
Phone: - -
PERMIT INFORMATION: Sticker for overcurrent protection must be on A/C equipment prior to
inspection. Failure to comply will result in a failed inspection and reinspect fees. No
exceptions.
FEES:
Furnaces and Heating $20.00
AC and Refrigeration $24.00
State Mech DBPR Surcharge $2.00
State Mech DCA Surcharge $2.00
Trade Permit Base Fee $55.00
Total Payments: $103.00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
4w� CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904) 247-5826 Fax (904) 247-5845
rOB ADDRESS: 2- Gl� Is-r PERMIT#
PROJECT VALUE $ 5000 ARI# 0-5 —REQUIRED
Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity I Tons Per Unit Seer Rating
Heat: Unit Quantity I BTU's Per Unit '3�4 coo
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps BTU's
#Vented Wall Furnaces Refrigerator Condenser
# Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
iis application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name G�a_t_ A60TCb� Phone Number Zq(-111 r
Mechanical Company 00�joyc-wj OfficePhone ZYi3'7rr Fax .2V(37
Co. Address: SK- 0- A4C S City JPX -a-), R State Zip3'Z-ZfD
License Holder(Print): "^v State Certification/Registration# CkU3qJ61
Notarized Signature of License Molder
Before me this 17 dnv nf /S- OA,, 20
Signature of Notary Publi,
c
Job:
+ wrightsoft Project Summary Date: October 5,2014
Entire House By: Aaron Thacker
Donovan Heat&Air
315 6th Ave S,Jacksonville Beach, FL32250 Phone�904-241-3785 Fax:904-241-3745 Email:aaron@donovanac.com Web:www.DonovanAC.com
Project Information
For-. Earl Hooten
172 6th St,Atlantic Beach, FL 32233
Notes:
Design Information
Weather: Jacksonville Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 39 'F Outside db 95 'F
Inside db 70 oF Inside db 75 oF
Design TD 31 oF Design TD 20 'F
Daily range L
Relative humidity 50 %
Moisture difference 53 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 26705 Btuh Structure 20836 Btuh
Ducts 4944 Btuh Ducts 4814 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
pipigg 0 Btuh
Equipment load 31649 Btuh Use manufacturer's data n
Rate/swin multiplier 1.00
Infiltration Equipmen?sensible load 25650 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 1154 Btuh
Ducts 2066 Btuh
Heati n Cooliv Central vent(0 cfm) 0 Btuh
Area (ft2) 1040 104 Equipment latent load 3220 Btuh
Volume (ft') 8320 8320
Air changes/hour 0.45 0.23 Equipment total load 28870 Btuh
Equiv.AVF (cfm) 62 32 Req. total capacity at 0.70 SHR 3.1 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carder
Trade COMFORT 15 PURON HP Trade COMFORT 15 PURON HP
Model 25HCB536A30 Cond 25HCB536A30
AHRI ref no3032539 Coil FV4BN(B,F)003
AHRI ref no3032539
Efficiency 8.5 HSPF Efficiency 13.0 EER, 15.5 SEER
Heating input Sensible cooling 24220 Btuh
Heating output 35000 Btuh @ 47'F Latent cooling 10380 Btuh
Temperature fisse 28 'F Total cooling 34600 Btuh
Actual air flow 1153 cfm Actual air flow 1153 cfm
Air flow factor 0.036 cfm/Btuh Air flow factor 0.045 cfm/Btuh
Static pressure 0 in H20 Static pressure 0 in H20
Space thermostat Load sensible heat ratio 0.89
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2014-Oct-07 14 46:48
,=t� + wrightsoft Right-Suite(ID Universal 8 0,24 RSU05995 Pagel
14C�Ck C-\Users\Owner\Documents\Wrightsoft HVAC\Bogus 3 ton.rup Calc=MJ8 Front Door faces: W