Loading...
133 Beach ave 2014 HVAC (2) CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD MECHANICAL HVAC PERMIATLANTIC BEACH,FL 32233 CALL BY 4PM FOR NEXT DAY Irj9P6X[MCNA2W21KE LINE 247-5814 ]OB IN ]ah ID 14 MECH-56 Job Type: MECHANICAL HVAC ONLY Description: 1 CU 1 AHU 2TONS Estimated Value: Issue Date: 9/25/2014 Expiration Date: 3/24/2015 PROPERTY ADDRESS: Address: 133 BEACH AVE RE Number: 170213-0000 PROPERTY OWNER: Name: KOGER TRUST, NANCY T Address: 133 BEACH AVE GENERAL CONTRACTOR INFORMATION: Name: DONOVAN HEATING & AIR Address: Phone: - - PERMIT INFORMATION: Sticker for overcurrent protection must be on A/C equipment prior to inspection. Failure to comply will result in a failed inspection and reinspect fees. No exceptions. FEES: AC and Refrigeration $20.00 State Mech DBPR Surcharge $2.00 State Mech DCA Surcharge $2.00 Trade Permit Base Fee $55.00 Total Payments: $79.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 fOB ADDRESS: (33 &C�A ► `'� PERMIT# PROJECT VALUE $ 450 0 V ARI# REQUIRED Air Handling Equipment Only LAir Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating REQUIRED Duct Systems: Total CFM REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity I Tons Per Unit Heat: Unit Quantity 1 BTU's Per Unit Seer Rating REQUIRED Duct Systems: Total CFM FIRE PREVENTION Re Fire Sprinkler System Quantity (Requires 3 sets of plans) ) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read its application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authori to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name Y�b(hz Phone Number.90 y�(1I -rp�y Mechanical Company v>1 �- Office Phone 7-03'1Cf Fax a�137y) Co. Address: 1 t S City J ,x b d- F I State Zip�ZWO License Holder (Print): I N�,. State Certification/Registration# 'W Notarized Signature of License Hold ,••;;Y:^s RICHARD TOMPKINS Before me this <::7S day r.-vt 20 � :: Commission#FF 040399 a, Expires July 29,2017 Signature of Notary Public % pF p;�,.``� Bonded TNu Troy Fan Instaenoe 800 85-70% Job: wri htsoft Project Summary Date: September 16,2014 9 Entire House By: Aaron Thacker Donovan Heat&Air 315 6th Ave S,Jacksonville Beach, FL 32250 Phone:904-241-3785 Fax:904-241-3745 Email:aaron@donovanac.com Web:www.DonovanAC.com Project • • For: Pam Moore 133 Beach Ave,Atlantic Beach, FL 32233 Notes: Design Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 99 'F Inside db 70 °F Inside db 75 °F Design TD 31 °F Design TD 24 °F Daily range L Relative humidity 50 Moisture difference 69 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 10754 Btuh Structure 9911 Btuh Ducts 1864 Btuh Ducts 3267 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 12617 Btuh Use manufacturer's data n Rate/swing multiplier 1.04 Infiltration Equipment sensible load 13705 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average 2241 Btuh Fireplaces 0 Ducts926926 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ftz) 1140 1140 Equipment latent load 3166 Btuh Volume (ft3) 9120 9120 Air changes/hour 0.45 0.23 Equipment total load 16872 Btuh Equiv.AVF (cfm) 68 35 Req. total capacity at 0.70 SHR 1.6 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade COMFORT 15 PURON SINGLE STAGE ... Trade COMFORT 15 PURON SINGLE STAGE ... Model 25HCC524A*`30 Cond 25HCC524A"`30 AHRI ref no3676233 Coil FV4BNF002 AHRI ref no3676233 Efficiency 9 HSPF Efficiency 12.5 EER, 15.5 SEER Heating input Sensible cooling 16660 Btuh Heating output 24000 Btuh @ 47°F Latent cooling 7140 Btuh Temperature rise 28 °F Total cooling 23800 Btuh Actual air flow 793 cfm Actual air flow 793 cfm Air flow factor 0.063 cfm/Btuh Air flow factor 0.060 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2014-Sep-23 12.03 19 wrightsoft Right-Suite®Universal 8.0.24 RSU05995 Page 1 �� C:\Users\Owner\Documents\Wrightsoft HVAC\Bogus 2 ton.rup Calc=MJ8 Front Door faces W