133 Beach ave 2014 HVAC (2) CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
MECHANICAL HVAC PERMIATLANTIC BEACH,FL 32233
CALL BY 4PM FOR NEXT DAY Irj9P6X[MCNA2W21KE LINE 247-5814
]OB IN
]ah ID 14 MECH-56
Job Type: MECHANICAL HVAC ONLY
Description: 1 CU 1 AHU 2TONS
Estimated Value:
Issue Date: 9/25/2014
Expiration Date: 3/24/2015
PROPERTY ADDRESS:
Address: 133 BEACH AVE
RE Number: 170213-0000
PROPERTY OWNER:
Name: KOGER TRUST, NANCY T
Address: 133 BEACH AVE
GENERAL CONTRACTOR INFORMATION:
Name: DONOVAN HEATING & AIR
Address:
Phone: - -
PERMIT INFORMATION: Sticker for overcurrent protection must be on A/C equipment prior to
inspection. Failure to comply will result in a failed inspection and reinspect fees. No
exceptions.
FEES:
AC and Refrigeration $20.00
State Mech DBPR Surcharge $2.00
State Mech DCA Surcharge $2.00
Trade Permit Base Fee $55.00
Total Payments: $79.00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904) 247-5826 Fax (904) 247-5845
fOB ADDRESS: (33 &C�A ► `'� PERMIT#
PROJECT VALUE $ 450 0 V ARI# REQUIRED
Air Handling Equipment Only LAir Handling Unit & Condenser Condenser Only
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating REQUIRED
Duct Systems: Total CFM
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity I Tons Per Unit
Heat: Unit Quantity 1 BTU's Per Unit Seer Rating REQUIRED
Duct Systems: Total CFM
FIRE PREVENTION Re
Fire Sprinkler System Quantity (Requires 3 sets of plans)
)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
its application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
ot. The permit does not give authori to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name Y�b(hz Phone Number.90 y�(1I -rp�y
Mechanical Company v>1 �- Office Phone 7-03'1Cf Fax a�137y)
Co. Address: 1 t S
City J ,x b d- F I State Zip�ZWO
License Holder (Print): I
N�,. State Certification/Registration# 'W
Notarized Signature of License Hold
,••;;Y:^s RICHARD TOMPKINS Before me this <::7S day r.-vt 20
� :: Commission#FF 040399
a, Expires July 29,2017 Signature of Notary Public
% pF p;�,.``� Bonded TNu Troy Fan Instaenoe 800 85-70%
Job:
wri htsoft Project Summary Date: September 16,2014
9 Entire House By: Aaron Thacker
Donovan Heat&Air
315 6th Ave S,Jacksonville Beach, FL 32250 Phone:904-241-3785 Fax:904-241-3745 Email:aaron@donovanac.com Web:www.DonovanAC.com
Project • •
For: Pam Moore
133 Beach Ave,Atlantic Beach, FL 32233
Notes:
Design Information
Weather: Jacksonville Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 39 °F Outside db 99 'F
Inside db 70 °F Inside db 75 °F
Design TD 31 °F Design TD 24 °F
Daily range L
Relative humidity 50
Moisture difference 69 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 10754 Btuh Structure 9911 Btuh
Ducts 1864 Btuh Ducts 3267 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 12617 Btuh Use manufacturer's data n
Rate/swing multiplier 1.04
Infiltration Equipment sensible load 13705 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average 2241 Btuh
Fireplaces 0 Ducts926926 Btuh
Heating Cooling Central vent (0 cfm) 0 Btuh
Area (ftz) 1140 1140 Equipment latent load 3166 Btuh
Volume (ft3) 9120 9120
Air changes/hour 0.45 0.23 Equipment total load 16872 Btuh
Equiv.AVF (cfm) 68 35 Req. total capacity at 0.70 SHR 1.6 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade COMFORT 15 PURON SINGLE STAGE ... Trade COMFORT 15 PURON SINGLE STAGE ...
Model 25HCC524A*`30 Cond 25HCC524A"`30
AHRI ref no3676233 Coil FV4BNF002
AHRI ref no3676233
Efficiency 9 HSPF Efficiency 12.5 EER, 15.5 SEER
Heating input Sensible cooling 16660 Btuh
Heating output 24000 Btuh @ 47°F Latent cooling 7140 Btuh
Temperature rise 28 °F Total cooling 23800 Btuh
Actual air flow 793 cfm Actual air flow 793 cfm
Air flow factor 0.063 cfm/Btuh Air flow factor 0.060 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.81
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2014-Sep-23 12.03 19
wrightsoft Right-Suite®Universal 8.0.24 RSU05995 Page 1
�� C:\Users\Owner\Documents\Wrightsoft HVAC\Bogus 2 ton.rup Calc=MJ8 Front Door faces W