1841 Ocean Grove 2014 HVAC CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
MECHANICAL HVAC PERMIATLANTIC BEACH, FL 32233
CALL BY 4PM FOR NEXT DAY Il130WU NICZ4PR0XE LINE 247-5814
]OB IN A
Job ID: 14-MECH-79
Job Type: MECHANICAL HVAC ONLY
Description: 1 CU 1AHU 3/4 TON
Estimated Value:
Issue Date: 9/25/2014
Expiration Date: 3/24/2015
PROPERTY ADDRESS:
Address: 1841 OCEAN GROVE DR
RE Number: 169598-0300
PROPERTY OWNER:
Name: SMITH, KRISTIN LYNN
Address: 1841 OCEAN GROVE DR
GENERAL CONTRACTOR INFORMATION:
Name: DONOVAN HEATING &AIR
Address:
Phone: - -
PERMIT INFORMATION: Sticker for overcurrent protection must be on A/C equipment prior to
inspection. Failure to comply will result in a failed inspection and reinspect fees. No
exceptions.
FEES:
AC and Refrigeration $12.00
State Mech DBPR Surcharge $2.00
State Mech DCA Surcharge $2.00
Trade Permit Base Fee $55.00
Total Payments: $71.00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph (9041) 247-5826 Fax
(904) 247-5845
10B ADDRESS: lla4l V�fiY1 1 7 Y76 'e ✓r PERMIT#
PROJECT VALUE $ I q 7 v ARI# S707-4-13 REQUIRED
Air Handling Equipment Only /G' Air Handling Unit & Condenser Condenser Only
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating REQUIRED
Duct Systems: Total CFM
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity t Tons Per Unit 3/f Is
Heat: Unit Quantity / BTU's Per Unit 9000 Seer Rating_REQUIRED
Duct Systems: Total CFM
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
# Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
tis application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name K r I f�`Q� Sr^,�t'1.. Phone Number Z yl ' Z
Mechanical Company D00 021".,j Office Phone 2y137,fJ" Fax 0�l
Co. Address: 31"; AVErj City Jan IRcL r' State Zip3 D
License Holder(Print): '-D - State Certification/Registration# CNCD 39-
xL—
Notarized Signature of License Holder
RICHARD TOMPKINS
Before me this �� day of 20.
Commission#FF 040399
,
,q Expires July 29,2017 Signature of Notary Public
•�};;PF °� Bonded Thru Troy Fain Inauranoe 800-385-7019
Job:
+ wrightsoft Project Summary Date: September 24,2014
Entire House By: Aaron Thacker
Donovan Heat&Air
315 6th Ave S,Jacksonville Beach, FL32250 Phone:904-241-3785 Fax:904-241-3745 Email:aaron@donovanac.com Web.vvww.DonovanAC.com
Proiect Information
For: Kristin Smith
1841 Ocean Grove Dr, Atlantic Beach, FL 32233
Notes:
� - • • •
Weather: Jacksonville Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 39 °F Outside db 99 °F
Inside db 70 °F Inside db 75 °F
Design TD 31 °F Design TD 24 °F
Daily range L
Relative humidity 50
Moisture difference 69 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 10302 Btuh Structure 12830 Btuh
Ducts 0 Btuh Ducts 0 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 10302 Btuh Use manufacturer's data n
Rate/swing multiplier 1.04
Infiltration Equipment sensible load 13344 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average 1327 Btuh
Fireplaces 0 Structure
p Ducts 0 Btuh
Heating Cooling Central vent (0 cfm) 0 Btuh
Area (ftz) 589 589 Equipment latent load 1327 Btuh
Volume (ft3) 5301 5301
tuh
Air changes/hour 0.61 0.32 Equipment total load 146 1.5. on
Equiv.AVF (cfm) 54 28 Req. total capacity at 0.75 SHR 5 ton ton
Heating Equipment Summary Cooling Equipment Summary
Make Gree Make Gree
Trade Rio Trade Rio
Model SEER 16.0, HSPF 8.6 Cond SEER 16.0, HSPF 8.6
AHRI ref no5202423 Coil GWH09KF-A3DN
AHRI ref no5202423
Efficiency 8.5 HSPF Efficiency 12.8 EER, 15 SEER
Heating input Sensible cooling 13343 Btuh
Heating output 17703 Btuh @ 47°F Latent cooling 4448 Btuh
17791 Btuh
Temperature rise 27 °F Total cooling
Actual air flow 593 cfm Actual air flow 593 cfm
Air flow factor 0.058 cfm/Btuh Air flow factor 0.046 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.91
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2014-Sep-25 10:48 50
wrightsoft Right-Suite®Universal 8.0 24 RSU05995 Page 1
C\Users\Owner\Documents\Wrightsoft HVAC\Bogus.75 ton rup Calc=MJ8 Front Door faces: S