Loading...
1841 Ocean Grove 2014 HVAC CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD MECHANICAL HVAC PERMIATLANTIC BEACH, FL 32233 CALL BY 4PM FOR NEXT DAY Il130WU NICZ4PR0XE LINE 247-5814 ]OB IN A Job ID: 14-MECH-79 Job Type: MECHANICAL HVAC ONLY Description: 1 CU 1AHU 3/4 TON Estimated Value: Issue Date: 9/25/2014 Expiration Date: 3/24/2015 PROPERTY ADDRESS: Address: 1841 OCEAN GROVE DR RE Number: 169598-0300 PROPERTY OWNER: Name: SMITH, KRISTIN LYNN Address: 1841 OCEAN GROVE DR GENERAL CONTRACTOR INFORMATION: Name: DONOVAN HEATING &AIR Address: Phone: - - PERMIT INFORMATION: Sticker for overcurrent protection must be on A/C equipment prior to inspection. Failure to comply will result in a failed inspection and reinspect fees. No exceptions. FEES: AC and Refrigeration $12.00 State Mech DBPR Surcharge $2.00 State Mech DCA Surcharge $2.00 Trade Permit Base Fee $55.00 Total Payments: $71.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (9041) 247-5826 Fax (904) 247-5845 10B ADDRESS: lla4l V�fiY1 1 7 Y76 'e ✓r PERMIT# PROJECT VALUE $ I q 7 v ARI# S707-4-13 REQUIRED Air Handling Equipment Only /G' Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating REQUIRED Duct Systems: Total CFM REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity t Tons Per Unit 3/f Is Heat: Unit Quantity / BTU's Per Unit 9000 Seer Rating_REQUIRED Duct Systems: Total CFM FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read tis application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name K r I f�`Q� Sr^,�t'1.. Phone Number Z yl ' Z Mechanical Company D00 021".,j Office Phone 2y137,fJ" Fax 0�l Co. Address: 31"; AVErj City Jan IRcL r' State Zip3 D License Holder(Print): '-D - State Certification/Registration# CNCD 39- xL— Notarized Signature of License Holder RICHARD TOMPKINS Before me this �� day of 20. Commission#FF 040399 , ,q Expires July 29,2017 Signature of Notary Public •�};;PF °� Bonded Thru Troy Fain Inauranoe 800-385-7019 Job: + wrightsoft Project Summary Date: September 24,2014 Entire House By: Aaron Thacker Donovan Heat&Air 315 6th Ave S,Jacksonville Beach, FL32250 Phone:904-241-3785 Fax:904-241-3745 Email:aaron@donovanac.com Web.vvww.DonovanAC.com Proiect Information For: Kristin Smith 1841 Ocean Grove Dr, Atlantic Beach, FL 32233 Notes: � - • • • Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 99 °F Inside db 70 °F Inside db 75 °F Design TD 31 °F Design TD 24 °F Daily range L Relative humidity 50 Moisture difference 69 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 10302 Btuh Structure 12830 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 10302 Btuh Use manufacturer's data n Rate/swing multiplier 1.04 Infiltration Equipment sensible load 13344 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average 1327 Btuh Fireplaces 0 Structure p Ducts 0 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ftz) 589 589 Equipment latent load 1327 Btuh Volume (ft3) 5301 5301 tuh Air changes/hour 0.61 0.32 Equipment total load 146 1.5. on Equiv.AVF (cfm) 54 28 Req. total capacity at 0.75 SHR 5 ton ton Heating Equipment Summary Cooling Equipment Summary Make Gree Make Gree Trade Rio Trade Rio Model SEER 16.0, HSPF 8.6 Cond SEER 16.0, HSPF 8.6 AHRI ref no5202423 Coil GWH09KF-A3DN AHRI ref no5202423 Efficiency 8.5 HSPF Efficiency 12.8 EER, 15 SEER Heating input Sensible cooling 13343 Btuh Heating output 17703 Btuh @ 47°F Latent cooling 4448 Btuh 17791 Btuh Temperature rise 27 °F Total cooling Actual air flow 593 cfm Actual air flow 593 cfm Air flow factor 0.058 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.91 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2014-Sep-25 10:48 50 wrightsoft Right-Suite®Universal 8.0 24 RSU05995 Page 1 C\Users\Owner\Documents\Wrightsoft HVAC\Bogus.75 ton rup Calc=MJ8 Front Door faces: S