440 Ocean Remodel addition 2014 j t J—Ij l
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
RESIDENTIAL ADDITION
MUST eftl: BY 4PM FOR NE)ff BAY 1N9PEff10N. 247 5814
JOB INFORMATION:
Job ID: 14-RADD-40
Job Type: RESIDENTIAL ADDITION
Description: remodel and addition
Estimated Value: $140,000.00
Issue Date: 9/26/2014
Expiration Date: 3/25/2015
PROPERTY ADDRESS:
Address: 440 OCEAN BLVD
RE Number: 170171-0000
GENERAL CONTRACTOR INFORMATION:
Name: BOSCO BUILDING CONTRACTORS
Address:
Phone: - -
PERMIT INFORMATION: PUBLIC WORKS:
Full right-of-way restoration, including sod, is required.
Roll off container company must be on City approved list and container cannot be placed on
City Right-of-Way. (Approved: Advanced Disposal, Realco, Republic Services, Shappelle's and
Waste Management.)
Full erosion control measures must be installed and approved prior to beginning any earth
disturbing activities. Contact Public Works (247-5834) for Erosion and Sediment Control
Inspection prior to start of construction.
FEES:
PLAN CHECK FEES $300.00
BUILDING PERMIT FEE $600.00
STATE DCA SURCHARGE $9.00
STATE DBPR SURCHARGE $9.00
UTIL REV RESIDENTIAL BLDG $50.00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
Total Payments• $968.00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
�,.,, ,w.; w„,rprti >r" {.' Ut!1t.Utivl. t C•Klvtt 1 f\1't'lM A 1 IkJIN
, c
FILE C 'M C I'I'Y OF ATLANTIC LEACH �,
800 Seminole Road, Atlantic Beach, VT X22 33
n
Q
Office (904) 247-5826 Fax (904) 247-5845
Job Address: qq(9 dc&.-t L9 Permit Num er:
e=G 1G - S - � 5
By
-� ��
Legal Description Parcel #
Work
poor —re a o d. t. �� .t
Valuation of��ork S Proposed Work heated/cooled fL!tLE. non-heated/cooled
Class of Work (circle one): New A 11-2 Alteration Repair Move Demolition pool/spa window/door
Use of existing/proposed structure(s) (circle one): Commercial a Residential a
If an existing structure, is a fire sprinkler system installed? (Circle one): Yes No N /A
Florida product Approval 4 j Root=
m
For multiple products use product approya orm
Describe in detail the type of•work to be performed: ae-J, avol.40',
Property Owner Information' / '
Name- S Address: yqo 0, �l✓r/t
City State_Zip .23 Phone --
G-Mail or Fax # (Optional) —
Contractor Information:
Company Name: _ t� �u ��c. °�L Qualif ing A gent• r� (J
Address: .� Cit �j�
--- - yt.L State= Tip-- ,Z
Office f hone_ U Job Site/Contact Number_9� �jlf-a72oi Fax# �/Y - 0
State Certification/Registration # L / 0,2/2
Architect Name& Phone #
Engineer's Name& Phone#
Fee Simple Title I]older Name and Address -
Bonding Company Name and Address
Mortgage Lender Name and Address
I pplirution i•+ ht rc by«rude to uhloin ct perntil/o cb/he+cork curd i«slu//«!iu«.e«s i«c/ic«lyd. /cer/i/i //tu!no+Turk or i«s!«!/«lion hos cu«r«rtatc rc/prior/o the
i.+arrancy o/
1111
r per«til orad rhul al!a or k+rill he perfi««ted to tura l Nrr s/attdi«ds e f ul/]encs re/�td«li«s�co«srr«eYiu«i«Ibis jurisdieliorr. /tis perr«il het canes rod/
and void iJ u•ark is no!cun«nenced a irhirr si.r(G)munlhs, or if conch«c lion or+ruck is sus rented ur abandoned Jur«perux/o/six(6)nu«rlhs at unr thrre a%!er
+ruck is comr«cnced. l rnulerslcrnd Ihul srpurutc perrnils roust he scctued Jor E/ecrricu/{Nock, /'lambing,Sikhs, Wel/s, Priols, Furnaces, Hoileis, Heiden,
Tanks acrd Air Courlilionen,etc.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS
TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH
YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF
COMMENCEMENT.
I hereby c•ertijv that l have read and exc«nined this cyrp ion«nd know the strut•to he it-tit,and correct. ,Ill provisions of/aws(lilt/ordinances governing this
(+pc of Work will he cunlplicd with +rheNrer, rerift he in ur nol. l%re grunting of«pernril docs nal Presuntc lu gii•c uuthurily r violale or c•«nc•e!the
pruris«nts(J arty other l dee stale, or local nr gu ng c•unsh•uclion or the perlorrnuttce(J c•onsh•uc•tion.
Signature of Owner Signature of Contrac
Print Name 5,),er- Sit-Y�� .......__ _ _ Print Name 44• gwec)
Sworn to and subscribed before me Sworn to and subscribed before me
this
J-7_ Day of-:� � -- k E this /Z Day of-- _ L W&LIAM.LtPOPtr
Notary Public,State of Florida ool _Notary Public,State of Florida
ommNotary Public - y t;- - :
Expires Oct.19,2a15
Notary Pub it c - — -` empires Oct 19,2095
Commission No.EE 128745 Commission No.EE 128745
Revised 01.26.10
DO NOT WRITE BELOW- OFFICE USE ONLY
Applicable Codes: 2010 FLORIDA BUILDING CODE
Review Result (circle one):
Approved Disapproved Approved w/ Conditions
Review Initials/Date: 1h
Development Size
Habitable Space 5 P Non-Habitable
Impervious area
Miscellaneous Information
Occupancy Group 4- -3
Type of Construction
Number of Stories '�-
Zoning District 2 S ta.
Max. Occupancy Load
Fire Sprinklers Required
Flood Zone NA
Conditions/Comments:
NOTICE OF COMMENCEMENT
rPREPARE IN DUPLICATE)
Permit No � Tax Folio No.
State of County of
To whom it may concern:
The undersigned hereby informs you that improvements will be made to certain real property, and in
accordance with Section 713 of the Florida Statutes, the following information is stated in this NOTICE OF
COMMENCEMENT.
Legal description of property being improved: 15-1
Adcress of property being improved: e,..-� !v /� �Gr,��r� �e FL,
General description of improvements: AddF ](C,-v h
Owner Sh L
Address U 0
Owner s interest in site of the improvement
wee S mpie Titleholder (if other than owner)
Name
Address
-Ontractor
t�
ACdresso�► r1 !� 7
Phone No /yLf-QL - 0 C� Fax No. / tel' �y�- 0.3c26j
Surety (if any)
Address Amount of bond $
Phone No Fax No.
Name and address of any person making a loan for the construction of the improvements.
Name
Address
Phone No. Fax No.
Name of Gerson within the State of Florida. other than himself, designated by owner upon wnom_nQt ces.Q�o.t,her, d
cocuments may be served:
Name Pnp
Address L. WWI
phone No
Fax No.
In addition to himself. owner designates the following person to receive a copy of the Lienor's Notice as arov ded in
Section 713.06 (2) (b), Florida Statutes. (Fill in at Owner's option).
Name
Address
Phone No Fax No.
�_xpiralion date of Notice of Commencement (the expiration date is one (1) year from the date of recording unless a
<..,.�. ...: Page I of I
F I L E 0 0 P Y :NE CqC
. __ ros��M Cuio F`r° 1111111 VIII VIII VIII VIII VIII IIID IIII IIII
�'''�'�:-.ss .wxwa:rr�a....s.a.._+a►:..�ar�rr r. t� •.°c
Print Date:
9/15/2014 3:06:37 11!N1
Transaction #: 2642965 00u,M
Receipt #: 2571516
Cashier Date: 9/15/2014 Ronnie Fussell
3:06:33 PM Clerk Circuit Court
(MCARTER) Duval County
501 West Adams St RM 1051
.Jacksonville, FL 32202
(904) 255-2000
('u_�1�,IIIcr IIIfi)lH1111k)�� Transaction Information Payment Summary,
DateReceived: 09/15/2014
Source Code: BEACH
O BOSCO BUILDING CONSTRACTORS Q Code: BEACH
INC Over the Total Fees $10.00
Return Code: Over
Total Payments $10.00
Trans Type: Recording
Agent Ret
Num:
1 Payments
-- $10.00
� '.(-'IIL:('h 7475
1 Recorded Items
BKiPG: 16911/2097 CP-N.2014208154
�\ (' OTIC'1; (_'O1\1'�11N('1�:��11�:N 1 Date:9/15/20143:06:23PM
From: SNYDER SCOTT To: BOSCO BUILDING
CONTACTORS INC
INDEXING $0.00
RECORDING i $10.00
U Search Items
U Miscellaneous Items
il /i1[' /Prnnwu„ %..7(11-il�c/Rt-rnrriinuMnr�ii�r'!�it;iii�l �lhll 915 2014
[i �cclENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
vWESTIMATED ENERGY PERFORMANCE INDEX* = 77
The lower the EnergyPerformance Index, the more efficient the home.
i.. 440 Ocean Blvd, Atlantic Beach, FL, 32233-
1.
2233-1. New construction or existing Addition 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=13.0 912.22 ft2
b. N/A R= ft
3. Number of units,if multiple family 1 c. N/A R= ft2
4. Number of Bedrooms 0(0) d. N/A R= ft2
10.Ceiling Types Insulation Area
5. Is this a worst case? No a. Under Attic(Vented) R=30.0 504.00 ft2
6. Conditioned floor area(ft2) 564 b. N/A R= ft2
7. Windows— Description Area c. N/A R= ft2
a. U-Factor: Dbl,U=0.35 99.00 ft2 11. Ducts R ft
a Sup:Attic, Ret:Main,AH: Main 6 100.8
SHGC: SHGC=0.35
b. U-Factor: N/A ft2
SHGC: 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ft2 a.Central Unit 18.0 SEER:13.00
SHGC:
d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency
SHGC:
a.Electric Heat Pump 18.0 HSPF:7.70
Area Weighted Average Overhang Depth: 1.000 ft.
Area Weighted Average SHGC: 0.350
8 Floor Types Insulation Area 14. Hot water systems-None required Ca N/A
a. Raised Floor R=19.0 412.00 ft2 a. p'
EF:
b.Slab-On-Grade Edge Insulation R=0.0 92.00 ft2
c. N/A R= ft2 b. Conservation features
15.Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building O�-114E S74TF
Construction through the above energy saving features which will be installed (or exceeded) IV _ ; o
in this home before final inspection. Otherwise, a new EPL Display Card will be completed ��,, ''%
based on installed Code compliant features. �
Builder Signature: Date:
Address of New Home: City/FL Zip: iti g�
- - -- 000 WE
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage(EEM)incentives if you obtain a Florida EnergyGauge Rating, Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software
TABLE 402.4.2
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Snyder 440 Ocean Blvd Builder Name: Bosco Building Contractor, Inc
Street: 440 Ocean Blvd Permit Office: Duval
City,State,Zip: Atlantic Beach ,FL ,32233- Permit Number:
Owner: Jurisdiction: 261100
Design Location: FL,Jacksonville
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier Exterior thermal envelope insulation for framed walls is installed in
substantial contact and continuous alignment with building envelope
air barrier.
Breaks or joints in the air barrier are filled or repaired.
Air-permeable insulation is not used as a sealing material.
Air- ermeable insulation is inside of an air barrier.
Ceiling/attic Air barrier in any dropped ceiling/soffit is substantially aligned with
insulation and any gaps are sealed.
Attic access(except unvented attic), knee wall door, or drop down
stair is sealed.
Walls Corners and headers are insulated.
Junction of foundation and sill plate is sealed.
Windows and doors Space between window/doorjambs and framing is sealed.
Rim joists Rim joists are insulated and include an air barrier.
Floors (including Insulation is installed to maintain permanent contact with underside
above-garage and cantilevered of subfloor decking.
floors) Air barrier is installed at any exposed edge of insulation.
Crawl space walls Insulation is permanently attached to walls.
Exposed earth in unvented crawl spaces is covered with Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations Duct shafts, utility penetrations, knee walls and flue shafts opening
to exterior or unconditioned space are sealed.
Narrow cavities Batts in narrow cavities are cut to fit, or narrow cavities are filled by
sprayed/blown insulation.
Garage separation Air sealing is provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures are air tight, IC rated, and sealed to drywall.
Exception—fixtures in conditioned space.
Plumbing and wiring Insulation is placed between outside and pipes. Batt insulation is cut
to fit around wiring and plumbing, or sprayed/blown insulation
extends behind piping and wiring.
Shower/tub on exterior wall Showers and tubs on exterior walls have insulation and an air barrier
separating them from the exterior wall.
Electrical/phone box on Air barrier extends behind boxes or air sealed-type boxes are
installed.
Common wall Air barrier is installed in common wall between dwelling units.
HVAC register boots HVAC register boots that penetrate building envelope are sealed to
subfloor or drywall.
Fireplace Fireplace walls include an air barrier.
EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software
FORM 405-10
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name Snyder 440 Ocean Blvd Builder Name Bosco Building Contractor, Inc
Street: 440 Ocean Blvd Permit Office Duval
City,State,Zip. Atlantic Beach,FL,32233- Permit Number.
Owner: Jurisdiction 261100
Design Location Ft Jacksonville
1 New construction or existing Addition 9 Wall Types(912.2 sqft.) Insulation Area
2 Single family or multiple family Single-family a Frame-Wood,Exterior R=13.0 912.22 ft'
b N/A R= ff
3 Number of units, if multiple family 1 c N/A R= ft'
4 Number of Bedrooms(Bedrms In Addition) 0(0) d N/A R= ft'
5 Is this a worst case? No 10.Ceiling Types (504.0 sqft) Insulation Area
a Under Attic(Vented) R=30.0 504.00 ft
6 Conditioned floor area above grade(ft') 564 b N/A R= ft'
Conditioned floor area below grade(ft) 0 c. NIA R= ft'
11 Duds R ft'
7 Windows(99 0 sqft-) Description Area a SupAttic,Ret: Main,AH:Main 6 100.8
a. U-Factor: Dbl, U=0.35 99.00 ft'
SHGC: SHGC=0.35
b U-Factor: N/A ft' 12.Cooling systems kBtu/hr Efficiency
SHGC: a.Central Unit 18.0 SEER:13.00
c U-Factor N/A ft'
SHGC: 13 Heating systems kBtu/hr Efficiency
d. U-Factor N/A ft' a Electric Heat Pump 18.0 HSPF:7.70
SHGC:
Area Weighted Average Overhang Depth: 1.000 ft
Area Weighted Average SHGC' 0.350 14 Hot water systems-None required
8 Floor Types (504.0 sqft) Insulation Area a Cap: N/A
EF:5.67435E26
a Raised Floor R=19 0 412.00 ft'
b Conservation features
b.Slab On-Grade Edge Insulation R=0.0 92.00 ft'
c. N/A R= ft' 15.Credits Pstat
Glass/Floor Area: 0.176 Total Proposed Modified Loads: 12 09 PASS
Total Standard Reference Loads: 15 78
1 hereby certify that the plans and specifications covered by Review of the plans and 11;1E ST4,
this calculation are in compliance with the Florida Energy specifications covered by this Qti0 _ �0�
Code. calculation indicates compliance
Home E rgy Services '
A a 1 en
with the Florida Energy Code. '•. •':`�„ O
PREPARED BY: _ _ _____ Before construction is completed €
DATE: this building will be inspected for �. y
compliance with Section 553.908
Statutes
tatutes
I hereby certify that this building, as designed, is in compliance Florida
with the Florida Energy Code. OD WE��
OWNER/AGENT: BUILDING OFFICIAL: 171
DATE. DATE:
Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist
9/16/2014 2:15 PM EnergyGaugeO USA-FlaRes2010 Section 405 4 1 Compliant Software Page 1 of 5
PROJECT
Title: Snyder 440 Ocean Blvd Bedrooms: 0 Address Type: Street Address
Building Type: User Conditioned Area: 564 Lot#
Owner: Total Stories: 2 Block/SubDivision:
#of Units: 1 Worst Case: No PlatBook:
Builder Name: Bosco Building Contractor,In Rotate Angle: 0 Street: 440 Ocean Blvd
Permit Office: Duval Cross Ventilation: County: Duval
Jurisdiction: 261100 Whole House Fan: City,State,Zip: Atlantic Beach,
Family Type: Single-family FL, 32233-
New/Existing: Addition
Comment:
CLIMATE
/ IECC Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Jacksonville FL—JACKSONVILLE—INT 2 32 93 70 75 1281 49 Medium
BLOCKS
Number Name Area Volume
1 Blockl 564 4512
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 Main 564 4512 No 1 0 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Main 26 ft 0 92 ft' __— 0.3 0 0.7
2 Raised Floor Main --__ --- 412 ft' 19 0.3 0 0.7
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Gable or shed Metal 564 ft' 126 ft' Medium 0.96 No 0.9 No 0 26.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 504 ft' N N
CEILING
# Ceiling Type Space R-Value Area Framing Frac _ Truss Type
1 Under Attic(Vented) Main 30 504 ft' 0.11 Wood
I
9/16/2014 2:17 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5
WALLS
Adjacent S ace Cavity Width Height Sheathing Framing Solar Below
# Omt To Walf Type_ _ p -$Value-___FLJn --FL in -- -Area.--_---R-Value_ Fractiao- AbsoL Grade°A
1 W Exterior Frame-Wood Main 13 10 0 8.75 0 87.5 ft2 0 0.23 0.8 0
2 N Exterior Frame-Wood Main 13 6 0 875 0 52.5 ft2 0 0.23 0.8 0
3 E Exterior Frame-Wood Main 13 10 0 8.75 0 87.5 ft2 0 0.23 0.8 0
4 S Exterior Frame-Wood Main 13 6 0 8 0 48,0 ft2 0 0.23 0.8 0
5 W Exterior Frame-Wood Main 13 5.5 0 8 0 44.0 ft2 0 0.23 0.8 0
6 N Exterior Frame-Wood Main 13 6 0 8 0 48.0 ft2 0 0.23 0.8 0
7 E Exterior Frame-Wood Main 13 5.5 0 8 0 44.0 ft2 0 0.23 0.8 0
8 W Exterior Frame-Wood Main 13 13.66 0 8 0 109.4 ft2 0 0.23 0.8 0
9 N Exterior Frame-Wood Main 13 35.25 0 8 0 282.0 ft2 0 0.23 0.8 0
10 E Exterior Frame-Wood Main 13 13.66 0 8 0 109.4 ft2 0 0.23 0.8 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 E Insulated Main Metal .28 4 6.7 26.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 S 4 Vinyl Low-E Double Yes 0.35 0.35 4.5 ft2 1 ft 0 in 1 ft 0 in None None
2 W 5 Vinyl Low-E Double Yes 0.35 0.35 4.5 ft2 1 ft 0 in 1 ft 0 in None None
3 N 9 Vinyl Low-E Double Yes 0.35 0.35 90.0 ft2 1 ft 0 in 1 ft 0 in None None
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Best Guess .0003 443.8 24.36 45.82 .2844 5.9018
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump None HSPF: 7.7 18 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit None SEER 13 18 kBtu/hr 540 cfm 0.75 1 sys#1
9/16/2014 2:17 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
DUCTS
---Supply---- ----Return---- Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 100.8 ft Main 25.2 ft' Default Leakage Main (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Coolin Jan Feb ]Mar Apr Ma Jun Jul Auge Oct Nov Dec
HeatinJan Feb lX]Mar f ;APr I
May f Jun 4 Jul 4 Au4 SeP 4 ;Oct f X�Nov f X}Dec
Ventingan Feb [X]Mar [X]Apr May [ Jun [ Jul [ Aug [ Se [X]Oct [XJ Nov [ ]Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
9/16/2014 2:17 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: 440 Ocean Blvd PERMIT#:
Atlantic Beach, FL, 32233-
MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details.
COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK
Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed.
Recessed lighting IC-rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces:
gasketed doors &outdoor combustion air. Must complete envelope
leakage report or visually verify Table 402.4.2.
Thermostat& 403.1 At least one thermostat shall be provided for each separate heating and
controls cooling system, Where forced-air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code.
403.3.3 Building framing cavities shall not be used as supply ducts.
Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in
Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric)or shutoff(gas). Circulating system pipes insulated to = R-2
+ accessible manual OFF switch.
Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical
ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower(HP)of= 1
&Spas HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor-retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70%of heat from
site-recovered energy. Off/timer switch required. Gas heaters minimum
thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters
minimum COP=4.0.
Cooling/heating 403.6 Sizing calculation performed &attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
equipment occasion cooling or heating capacity requires separate system or
variable capacity system. Electric heat>10kW must be divided into two
or more stages.
Ceilings/knee walls 405.2.1 R-19 space permitting.
9/16/2014 2:17 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5
FILE COPY
Snyder 440 Ocean Blvd
HVAC Load Calculations
for
ti•n div . . . . n 1 l f ] f f n
RHVACREsIDEN`I7AL
HVAC LOADS
Prepared By:
Jim Williams
Home Energy Services
2060 Davis Rd
Jacksonville FI 32218
7573569
Thursday, September 18, 2014
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Home Energy Services Snyder 440 Ocean Blvd
Jacksonville,FL 32218 Pa e 2
Project Report
General Project Information
Project Title: Snyder 440 Ocean Blvd
Project Date: Tuesday, September 16, 2014
Client Name: Bosco Building Contractor, Inc
Client Address: 2158 Mayport Road
Client City: Atlantic Beach, FL 32233
Client Phone: 904-241-0320
Client Fax: 904-241-0326
Client E-Mail Address: Todd@Boscocustomhomes.com
Company Name: Home Energy Services
Company Representative: Jim Williams
Company Address: 2060 Davis Rd
Company City: Jacksonville FI 32218
Company Phone: 7573569
Company E-Mail Address: ecalcs@hesjax.com
Company Website: www.hesjax.com
Design Data
Reference City: Jacksonville, Florida
Building Orientation: Front door faces South
Daily Temperature Range: Medium
Latitude: 30 Degrees
Elevation: 26 ft.
Altitude Factor: 0.999
Outdoor Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
Winter: 32 29.92 80% n/a 70 n/a
Summer: 94 77 47% 50% 75 48
Check Figures
Total Building Supply CFM: 2,337 CFM Per Square ft.: 0.779
Square ft. of Room Area: 3,001 Square ft. Per Ton: 608
Volume(ft')of Cond. Space: 26,882
Building Loads
Total Heating Required Including Ventilation Air: 54,395 Btuh 54.395 MBH
Total Sensible Gain: 51,373 Btuh 87 %
Total Latent Gain: 7,841 Btuh 13 %
Total Cooling Required Including Ventilation Air: 59,214 Btuh 4.93 Tons(Based On Sensible + Latent)
Notes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:\ ...\Snyder4400ceanBlvd.rhv Thursday, September 18, 2014, 10:33 AM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. j
Home Energy Services Snyder 440 Ocean Blvd
Jacksonville,FL 32218 Pa e 3
[Miscellaneous Report
System 1 Main Outdoor Outdoor Outdoor Indoor Indoor Grains
In ut Data Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
Winter: 32 29.92 80% n/a 70 n/a
Summer: 94 77 47% 50% 75 48.06
System 2 2nd Floor Outdoor Outdoor Outdoor Indoor Indoor Grains
Input Data Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
Winter: 32 29.92 80% n/a 70 n/a
Summer: 94 77 47% 50% 75 48.06
Duct Sizing Inputs
-------- ---------
Main Trunk Runouts
Calculate: Yes Yes
Use Schedule: Yes Yes
Roughness Factor: 0.00300 0.01000
Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft.
Minimum Velocity: 650 ft./min 450 ft./min
Maximum Velocity: 900 ft./min 750 ft./min
Minimum Height: 0 in. 0 in.
Maximum Height: 0 in. 0 in.
Outside Air Data
Winter Summer
Infiltration Specified: 0.317 AC/hr 0.317 AC/hr
142 CFM 142 CFM
Infiltration Actual: 0.317 AC/hr 0.317 AC/hr
Above Grade Volume: X 26,882 Cu.ft. X 26,882 Cu.ft.
8,523 Cu.ft./hr 8,523 Cu.ft./hr
X 0.0167 X 0.0167
Total Building Infiltration: 142 CFM 142 CFM
Total Building Ventilation: 0 CFM 0 CFM
---System 1---
Infiltration & Ventilation Sensible Gain Multiplier: 20.88 = (1.10 X 0.999 X 19.00 Summer Temp. Difference)
Infiltration &Ventilation Latent Gain Multiplier: 32.65 = (0.68 X 0.999 X 48.06 Grains Difference)
Infiltration &Ventilation Sensible Loss Multiplier: 41.76 = (1.10 X 0.999 X 38.00 Winter Temp. Difference)
Winter Infiltration Specified: 0.350 AC/hr(105 CFM)
Summer Infiltration Specified: 0.350 AC/hr(105 CFM)
---System 2---
Infiltration &Ventilation Sensible Gain Multiplier: 20.88 = (1.10 X 0.999 X 19.00 Summer Temp. Difference)
Infiltration &Ventilation Latent Gain Multiplier: 32.65 = (0.68 X 0.999 X 48.06 Grains Difference)
Infiltration &Ventilation Sensible Loss Multiplier: 41.76 = (1.10 X 0.999 X 38.00 Winter Temp. Difference)
Winter Infiltration Specified: 0.250 AC/hr(37 CFM)
Summer Infiltration Specified: 0.250 AC/hr(37 CFM)
Duct Load Factor Scenarios for System 1
Attic Duct Duct Surface From
No. Type Description Location Ceiling Leakage Insulation Area MDD
1 Supply Main Attic 16B 0.12 6 513 No
1 Return Main Attic 16B 0.24 6 190 No
Duct Load Factor Scenarios for System 2
Attic Duct Duct Surface From
No. Type Description Location Ceiling Leakage Insulation Area MDD
1 Supply Main Attic 16B 0.09 6 298 No
1 Return Main Attic 16B 0.15 6 55 No
C:\ ...\Snyder4400ceanBlvd.rhv Thursday, September 18, 2014, 10:33 AM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Home Energy Services Snyder 440 Ocean Blvd
Jacksonville,FL 32218 Page 4
Load Preview Report
Net Recqfrftn
Sen Lat Net Sen Sys' Sys Sys CAct pact
Scope Ton Ton! AreaGan Gain Gain Loss CFM CFM CFM Size
Building 4.93 5.71 526 3,001 51,373 7,841 59,214 54,395 1,100 2,337 2,337
System 1 3.54 4.05 469 1,899 36,445 6,072 42,516 37,149 751 1,658 1,658 1419
Duct Latent 1,639 1,639
Zone 1 1,899 36,445 4,433 40,878 37,149 751 1,658 1,658 14x19
1-Living 759 16,353 2,239 18,592 16,995 344 744 744 7-5
2-K ichen 252 5157 637 5,794 3,646 74 235 235 3-5
3-Laundry 33 668 231 899 1,714 35 30 30 1-4
4-Powder 17 145 60 205 413 8 7 7 1-4
5-Family Room 293 6,099 623 6,722 6,424 130 277 277 3-5
7-Master Bedroom 323 5,889 382 6,271 3,687 75 268 268 3-5
8-M WIG 128 800 151 951 1,364 28 36 36 1-4
9-Master Bath 94 1,333 110 1,443 2,906 59 61 61 1-4
System 2 1.39 1.66 664 1,102 14,928 1,770 16,698 17,246 349 679 679 10x14
Duct Latent 564 564
Zone 1 1,102 14,928 1206 16,134 17,246 349 679 679 10x14
6-Storage 60 1,410 213 1,623 3,703 75 64 64 1-5
10-2nd Floor Landing 120 414 0 414 283 6 19 19 1-4
11-Room 1 174 2,968 225 3,193 2,294 46 135 135 2-5
12-13ath 2 120 898 75 973 898 18 41 41 1-4
13-Bedroom 2 216 3,114 225 3,339 4,358 88 142 142 2-5
14-New Bonus Room 412 6,124 468 6,592 5,711 115 279 279 3-5
C:\ ...\Snyder4400ceanBlvd,rhv Thursday, September 18, 2014, 10:33 AM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Home Energy Services Snyder 440 Ocean Blvd
Jacksonville,FL 32218 Page 5
Duct Size Preview
Room or Minimum Maximum Rough. Designi SP', Duct Duct g Clg Act, Duct
Duct Name Veloci Velocity Factor L/100 Loss I_ Veloci Len h Ht
---- -- � H H � Flow Flow Flow Size
System 1 _ __
Supply Runouts
Zone 1
1-Livi ng 450 750 0 0.1 541.3 344 # 744 744 7-5
2-Kitchen 450 750 0 0.1 573.6 74} 235 235 3--5
3-Laundry 450 750 0 0.1 348.5 35 30 30 1-4
4-Powder 450 750 0 0.1 75.7 8} 7 7 1-4
5-Family Room 450 750 0 0.1 471.1 130 277 277 3-5
7-Master Bedroom 450 750 0 0.1 454.8 75 268 268 3-5
8-M WIC 450 750 0 0.1 417.4 281, 36 36 1-4
9-Master Bath 450 750 0 0.1 694.9 59£ 61 61 1-4
Other Ducts in System 1
Supply Main Trunk 650 900 0 0.1 897.6 751 1,658 1,658 14x19
System 2
Supply Runouts
Zone 1
6-Storage 450 750 0 0.1 470.5 75 64 64 1-5
10-2nd Floor Landing 450 750 0 0.1 215.7 6 19 19 1-4
11-Room 1 450 750 0 0.1 495.2 46 ,135 135 2-5
12-Bath 2 450 750 0 0.1 468 18 W41 41 1-4
13-Bedroom 2 450 750 0 0.1 519.6 88 JW 142 2-5
14-New BonusRoom 450 750 0 0.1 473 115 IM79 279 3-5
Other Ducts in System 2
Supply Main Trunk 650 900 0 0.1 698.6 349 Mm" 679 10x14
Summary
System 1
Heating Flow: 751
Cooling Flow. 1658
System 2
Heating Flow: 349
Cooling Flow: 679
C:\ ...\Snyder4400ceanBlvd.rhv Thursday, September 18, 2014, 10:33 AM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Home Energy Services Snyder 440 Ocean Blvd
Jacksonville,FL 32218 Page 6
Total Building Summary Loads
Component Area Sen Lat Sen Total
Description Quan Loss Gain Gain Gain
1 D-cb-o: Glazing-Double pane, operable window, clear, 154.2 3,812 0 7,668 7,668
metal frame with break, u-value 0.65, SHGC 0.67
1OA-f: Glazing-French door, single pane clear glass, 54.5 1,451 0 1,234 1,234
insulated fiberglass frame, u-value 0.7, SHGC 0.45
1D-cb-o: Glazing-Double pane, operable window, clear, 30 740 0 1,528 1,528
metal frame with break, outdoor insect screen with
50% coverage, light color blinds at 45°with 50%
coverage, u-value 0.65, SHGC 0.67
4A-6-o: Glazing-Double pane low-e(e = 0.20 or less), 90 1,200 0 1,254 1,254
high performance, operable window, e=0.05 on
surface 2, any frame, u-value 0.35, SHGC 0.35
11J: Door-Metal - Fiberglass Core 26.8 611 0 482 482
12B-Osw: Part-Frame, R-11 insulation in 2 x 4 stud cavity, 378.5 1,395 0 698 698
no board insulation, siding finish, wood studs
12B-Osw: Wall-Frame, R-11 insulation in 2 x 4 stud 1816.4 6,694 0 4,953 4,953
cavity, no board insulation, siding finish,wood studs
12C-Osw: Wall-Frame, R-13 insulation in 2 x 4 stud 611.4 2,115 0 1,420 1,420
cavity, no board insulation, siding finish, wood studs
1613-19: Roof/Ceiling-Under Attic with Insulation on Attic 2034.7 3,787 0 5,385 5,385
Floor(also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-19 insulation
1613-30: Roof/Ceiling-Under Attic with Insulation on Attic 412 501 0 712 712
Floor(also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-30 insulation
22A-ph-c: Floor-Slab on grade, No edge insulation, no 274 14,139 0 0 0
insulation below floor, carpet covering, passive,
heavy moist soil
20P-19: Floor-Over open crawl space or garage, Passive, 412 783 0 288 288
R-19 blanket insulation, any cover
Subtotals for structure: 37,228 0 25,622 25,622
People: 5 1,000 1,150 2,150
Equipment: 0 9,600 9,600
Lighting: 0 0 0
Ductwork: 11,236 2,202 11,571 13,773
Infiltration: Winter CFM: 142, Summer CFM: 142 5,931 4,639 2,967 7,606
Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0
AED Excursion: 0 0 463 463
Total Building Load Totals: 54,395 7,841 51,373 59,214
Check Figures
Total Building Supply CFM: 2,337 CFM Per Square ft.: 0.779
Square ft. of Room Area: 3,001 Square ft. Per Ton: 608
Volume(ft')of Cond. Space: 26,882
Building Loads
Total Heating Required Including Ventilation Air: 54,395 Btuh 54.395 MBH
Total Sensible Gain: 51,373 Btuh 87 %
Total Latent Gain: 7,841 Btuh 13 %
Total Cooling Required Including Ventilation Air: 59,214 Btuh 4.93 Tons(Based On Sensible + Latent)
Notes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
C:\ ...\Snyder4400ceanBlvd.rhv Thursday, September 18, 2014, 10:33 AM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Home Energy Services Snyder 440 Ocean Blvd
Jacksonville,FL 32218 Page 7
Total Building Summary Loads cont'd
Notes
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:\ ...\Snyder4400ceanBlvd.rhv Thursday, September 18, 2014, 10:33 AM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Home Energy Services Snyder 440 Ocean Blvd
Jacksonville,FL 32218 Page 8
Building Pie Chart
Infiltration 11%
Floor 27%
Ductwork 21%
Building
Loss
54,395
Btuh
Roof 8% Door 1%
Glass 13%
Wall 19%
Floor 0% ED Excursion 1%
Roof 10% Infiltration 13%
Wall 12%
Building Ductwork 23%
Gain
59,214
Btuh
Glass 20%
People10 4% Equipment 16%
C:\ ...\Snyder4400ceanBlvd.rhv Thursday, September 18, 2014, 10:33 AM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Home Energy Services Snyder 440 Ocean Blvd
Jacksonville,FL 32218 Page 9
SI ysfem 1 Room Load Summary
Htg Min Run Run Clg Clg Min Acf
Room Area Sens Htg Duct Duct Sens Lat Cig Sys
No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM
---Zone 1---
1 Living 759 16,995 344 7-6 541 16,353 2,239 744 744
2 Kitchen 252 3,646 74 3-5 574 5,157 637 235 235
3 Laundry 33 1,714 35 1-4 348 668 231 30 30
4 Powder 17 413 8 1-4 76 145 60 7 7
5 Family Room 293 6,424 130 3-6 471 6,099 623 277 277
7 Master Bedroom 323 3,687 75 3-6 455 5,889 382 268 268
8 M WIC 128 1,364 28 1-4 417 800 151 36 36
9 Master Bath 94 2,906 59 1-4 695 1,333 110 61 61
_ Duct Latent 1,639
System 1 total 1,899 37,149 751 36,445 6,072 1,658 1,658
System 1 Main Trunk Size: 14x19 in.
Velocity: 898 ft./min
Loss per 100 ft.: 0.097 in.wg
Cooling Systam Si
Cooling Sensible/Latent Sensible Latent Total
Tons Split Btuh Btuh Btuh
Net Required: 3.54 86% / 14% 36,445 6,072 42,516
Actual: 4.00 75%/25% 36,000 12,000 48,000
Equipment Data
Heating System Cooling System
Type: Air Source Heat Pump Air Source Heat Pump
Model: 4TW B3048B 1 4TW B3048B 1
Indoor Model: TEM4AOC48S41+TDR
Brand: TRANE TRANE
Description: Air Source Heat Pump Air Source Heat Pump
Efficiency: 7.7 HSPF 13 SEER
Sound:
Capacity: 45000 48000
Sensible Capacity: n/a 36,000 Btuh
Latent Capacity: n/a 12,000 Btuh
AHRI Reference No.: n/a 7424768
C:\ ...\Snyder4400ceanBlvd.rhv Thursday, September 18, 2014, 10:33 AM
Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc.
Home Energy Services Snyder 440 Ocean Blvd
Jacksonville,FL 32218 Page 10
System 2 Room Load Summary
Htg Min Run Run Clg Clg Min Act
Room Area Sens Htg Duct Duct Sens Lat Cig Sys
No Name SF Btuh CFM Size Vel Btuh Btuh _ CFM CFM
---Zone 1---
6 Storage 60 3,703 75 1-5 471 1,410 213 64 64
10 2nd Floor Landing 120 283 6 1-4 216 414 0 19 19
11 Room 1 174 2,294 46 2-5 495 2,968 225 135 135
12 Bath 2 120 898 18 1-4 468 898 75 41 41
13 Bedroom 2 216 4,358 88 2-5 520 3,114 225 142 142
14 New Bonus Room 412 5,711 115 3-6 473 6,124 468 279 279
Duct Latent 564
System 2 total 1,102 17,246 349 14,928 1,770 679 679
System 2 Main Trunk Size: 10x14 in.
Velocity: 699 ft./min
Loss per 100 ft.: 0.090 in.wg
Cooling System S
Sensib!e/Latent Sensible Latent
Split Btuh Btuh
Net Required: 1.39 89% / 11% 14,928 1,770 16,698
Actual: 1.50 75%/25% 13,500 4,500 18,000
Equipment Data
Heating System Coolinq System
Type: Air Source Heat Pump Air Source Heat Pump
Model: 4TWB3018D1 4TWB3018D1
Indoor Model: 4FWM(A,F)031A'
Brand: TRANE TRANE
Description: Air Source Heat Pump Air Source Heat Pump
Efficiency: 7.7 HSPF 13 SEER
Sound:
Capacity: 17600 18000
Sensible Capacity: n/a 13,500 Btuh
Latent Capacity: n/a 4,500 Btuh
AHRI Reference No.: n/a 6885377
C:\ ...\Snyder4400ceanBlvd.rhv Thursday, September 18, 2014, 10:33 AM
City of Atlantic Peach -
APPLICATION NUMBER
>' • � Building Department (To be i�ed b the Building Dep ment.)
800 Seminole Road
Atlantic Beach, Florida 32233-5445
Phone(904)247-5826 • Fax(904) 247-5845 g
'r){tl jr E-mail: building-dept@coab.us Date routed: 9 7
City web-site: http://www.coab.us �-
APPLICATION REVIEW AND TRACKING FORM
Property Address: '/M0 d �GGE'�1 4MCL Depart--nent review required lies No
uildin
Applicant; 451anning & Zonin
re is rator
Project; If-04 /4Z__k7JVd_n u lic Works
is Sare y
Fire Services
Review fee $ Dept Signature
Other Agency Review or Permit Required Review or Rece , ;: Date
of Permit Verified By
Florida Dept.of Environmental Protection
Florida Dept. of Transportation
St. Johns River Water Management District
Arany Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: XApproved, ❑Denied.
(Circle one.) Comments:
BUILDING
PLANNING &ZONING Reviewed by: Daie:
TREE ADMIN. Second Review: A roved as revised.
❑ pp []Denied.
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by.- Date:
FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied.
Comments:
Reviewed by: Date:
evised 05/14/09
City of Atlantic Peach APPLICATION NUMBER
Building Department (To be i�ed b the Building Depaaa���ment.)
Seminole Road
�; Atlatla ntic Beach, Florida 32233-5445
Phone (904)247-5826 • Fax(904) 247-584' E P
E-mail.- building-dept@coab.us Date routed:
9 i q i
City web-site: http://www,coab.us
APPLICATION REVIEW AND TRACKING FORM
Property Address: '/Ml) Q �G�� BlV1- Department review required Yes lQl®
uniApplicant; ��D tanning &Zonin
t-1,77�`Isai:o,
Project; 04 u tic Works
grt...�
is Sae y
Fire Ser vices
:Review free $ Dept Signature
Other Agency Review or Permit Required Review or Rece ,:rt: ®ate
Florida Dept.of Environmental Protection of Permit Verified By
Florida Dept. of Transportation
St. Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other.-
APPLI A(TION STATUS
Reviewing Department First Review: Approved. ❑Denied.
(Circle one.) Comments:
BUILDING
PLANNING &ZONING Reviewed by: - C� Date:
TREE ADMIN. Second Review: ❑Approved as revised. enied.
PUBLIC WORKS Comments:
PUBLIC UTILITIES
PUBLIC SAFETY Reviewed by: Date:
FIRE SERVICES Third Review: []Approved as revised. ❑Denied.
Comments:
Reviewed by: Date:
evised 05/14/09
City or Atlantic Peach APPLICATION NUMBED
r
Building Department ' (To be assigned b the Building Dep ment.)
800 Seminole RoadVr�'�
a�� + / A »
Atlantic Beach, Florida 32233-5445
Phone (904)247-5826 - Fax(904) 247-58KP 19 2014
E-mail: building-dept@coab.us Date routed:
City web-site: http://www.coab.us -
APPLICATION REVIEW AND TRACK9NG FORM
Property Address: '/MQ Q 1,6A-71 6/va_ Department review required Yep leo
IlTuildinci.
Applicant: S't 6 tanning & Zonin
ree Mnis-T—ra—tor
Project: u lic Works
t..a
7eS
Sa,e y
Fr Vices
Review fee Dept Signature<2
Other Agency Review or Permit RequiredReview or Re4:y",4
of Permit Verified By ®ate
Florida Dept.of Environmental Protection
Florida Dept. of Transportation
St.Johns River Water Management District
Army Corps of Engineers
Division of Hotels and Restaurants
Division of Alcoholic Beverages and Tobacco
Other:
APPLICATION STATUS
Reviewing Department First Review: Approved. ❑Denies:+.
(Circle one.) Comments: r
BUILDING
PLANNING &ZONING
Reviewed by: Date:
TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied.
J
WSAFET
Comments:
Reviewed by: Date:
FIRE SERVICES Third Review: []Approved as revised. []Denied.
Comments:
Reviewed by: Date:
evised 05/14/09
60'RIGHT OF WAY. PAVED PUBLIC ROAD
OC EAN BOULEVARD -
II
u (9172'ilELO i I
a. 1 w
76* I w S�
I �-
il l
I I
1
W 0
O I LL
�....z O
z
O.liJ � $
1-..p
o
c G w SS4S � 1
In n Q
g 0
W 0
J U
W
S
V
Q W o 0
7n,7 �� sa-
Q
g;TORY ;.
A9�.TH}IJ `I
1 _
_ I
of YZ� I
`o --—
�� I (01311,VO'CS'
-UI SJ
LOT 33 � l07 37
I
1
PLAT BOOK 15. PAGE 34
ATLANTIC BEACH TERRACE
60'RIGHT OF WAY, PAVED PUBLIC ROAD
OCEAN BOULEVARD -
r63.46
06 FI;LD) _
o
of
4 C
a kan o
S yYI F-
7.6'
7.ti ui
I 1
W
of 3
I
2 Z v I b
j
a
c) - � UI 0_ Q O� I
'c Q N lil LJ Q w I
a In [] m in n
Z IT
o Q
U- w
Q -
SLC�t' W w u
J 0
7 J
a O
W U
nroc w
I _
(0131.1,i0'OS)
LOT 33 I LOT 32 LOT 30
I
I
PLAT BOOK 15, PAGE 34
ATLANTIC BEACH TERRACE
§ �
( / § • \� \
k ) / )®7
( ) § § \
§ \ (
) ( 333 ;z 7 § 2f |
§ mom ,
) \ / ( \ ( \ \ � / {
ff § ef / / on27 ,
!
} �
A
o �
S
c1=3
, ; ¢
]§
c
r-3c
>�
222)m
R
\ )k �� ƒ __
: \ 2\
§ ! 4 �« r31=1
_ )
w
\ )
k I;v $
- ( k) o
■&
- |
}o
o
%
\
( A BE FIELD S
REPRODUCED,ARE NOT TO BE _ �__`~_ ` »
B\soI Scott__� " 110
d
`~ ^ a--
m ,NN3 eme AWold °®°°� ...,..�......o.,...>
suo!IeA813 Pas�ld I•z+ro xva yo..B Jgl-pV �ro•z+ae 3NONa ea
'PAIR--o OM vx>v3e aum.v NO SO
E-d o wuz 18P(Ug uooS mae wa YNesLz 8
0
_ -"' '^" -lOtl1N00103EOtld
-SNOISN3W10031V3S N3 O 30N30303Hd 3AVH IWWS SNOISN3W10 N3111HM N1383H a31SI11N3110 NVH1 H3H103NOANV 0103NN3ASNVN1 HO'H3NN IN ANY N1030NVH0030000Hd3H 380110.3HY A3H1
-03131H3AO1313 M0 S BOf 3H1 NO SNOI110N000NV SNOISN3MG]IV I ONUS 3YI00003S3H1 40 S1 OIH ALH3dONd H3H100NV 1HOIHAd00 MV1 NOW"003.1 S3AH3S3H'ONI'SHOID"IN000NI011Oe 00508 g
i
O
I
I 1-.LZ 0
I o
S
%P.LI f 0
o
ii
0
I
.lL-.LL w
OO m
AA -2 O
A.E kA 11 n
1-,lZ �
:F4£ AA I •s-A II I
j O OIz
`o
I 1 a
EMEM
iz
I a
I
j . I
C31=3
-
I
I
j
o-
a w
a - s
I
I.
4F II 1 I 11 O
O
I
1-.L2
II I a
1 .LL-.tZ 1
2
3
z
1
I
2-.lL i
t. � .%,P.Lnj •��
I
I ZO
I �
Z I� W
Ir J
W
I � C
w I ® O
w I � o
w r
j Ov w
g � w
ab
w
Q
ELI I
a
I io-.Lti
I I 1 1 1 11 K
j I `
i I i
j I 11 I II
F .Yo.l •�'
.LL-.LZ
5 1
3 I
9
i
3
O
0
0
0
2
0
----------
T
------------ - -------------
o
>1
10
yO
-----------
0
O rvE
Cop DOCUMENTS AND Al-l-DIMENSIONS AND CONDITIONS ON THE SHALL BE FIELD VERIFIED.
Ni
BOSCO BUILDING CONTRACTORS INC,RESERVES THE COM t-AW COPYRIGHT AND OTHER PROPERTY RIGHTS OF THESE
THEY ME NOT TO BE REPRODUCED CHANGED IN MY MANNER.OR TRANSFERRED TO ANYONE OTHER THAN CLIENT LISTED HEREIN. WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS.
PROJECT CONTACT:eir
Ocean lvd.
Fa Bosco h— Scott Snyd
Floridatla tic 32233 Beach Exialing Flm Plans
,6' ' CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
J r ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
ELECTRICAL PERMIT
MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814
JOB INFORMATION:
Job ID: 14-ELEC-452
Job Type: ELECTRIC ONLY
Description: fixtures
Estimated Value:
Issue Date: 11/18/2014
Expiration Date: 5/17/2015
PROPERTY ADDRESS:
Address: 440 OCEAN BLVD
RE Number: 170171-0000
PROPERTY OWNER:
Name: SNYDER, SCOTT
Address: 440 OCEAN BLVD
GENERAL CONTRACTOR INFORMATION:
Name: ERICKSON ELECTRICAL CONTRACTOR
Address: 2807 ST JOHNS QA FRANK W ERICKSON
Phone• - -
FEES:
State Elec DBPR Surcharge $2.00
State Elec DCA Surcharge $2.00
Lighting Outlets, Including Fixtures $7.20
Trade Permit Base Fee $55.00
Total Payments: $66.20
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
ELECTRICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd,Atlantic Beach, FL 32233
Ph(904) 247-5826 Fax (904) 247-52"5
�- wkJOB ADDRESS: 44 1i _ PERMIT #
JEA INFORMATION REQUIRED ON ALL PERMITS AMPS y�ZiD VOLTS PHASE
VAL UE OF WORK$
NEW SERVICE ❑ Overhead ❑ Underground ❑1 Underground up Pole
iaResidential(Main)Service
❑0-100 amps ❑101-150amps ❑151-200amps ❑ amps #of Meters
❑Commercial(Main) Service
00-100 amps ❑101-150amps ❑151-200amps ❑ amps OCT Service amps
Conductor Type Size
[]Multi-Family(Main)Service
❑0-100 amps ❑101-150amps ❑151-200amps ❑ amps #of Unit Meters
❑Temporary Pole ❑ amps
SERVICE UPGRADE ❑ amps 1, CT Service amps
NEW FEEDER(ADDITIONS,ACCESSORY STRUCTURES,ETC.)
❑100 amps ❑150amps 0200amps amps [I CT Service amps
ADDITIONS,REMODEL,,REPAIRS,BUILD-OUTS,ACCESSORY STRUCTURES,ETC.
Outlets/Switchi 61 0-3 Damps 31-100amps 101-200amps
Appliances: 0-30amps 31-l 00amps 101-200amps
A/C Circuits: 0-60amps 61-100amps
Heat Circuits: # circuits @ kw
Number of Lighting Outlets, Including Fixtures:
OTHER ELECTRICAL PROJECTS i
❑Swimming Pool ❑ Sign ❑Smoke Detectors_Qty ❑Transformers KVA ❑Motors hp
FIRE ALARM SYSTEM (Requires 3 sets of plans)
Qty volts/amps VAL UE OF WORK$
REPAIRS/MISCELLANEOUS
7-Replace Burnt/Damaged Meter Can El Safety Inspection -,Panel Change DOH to UG
L]Other:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have
read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether
specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of
construction. rr�� I
Property Owners Nameyff i �1 V Phone Number -1A —
Electrical Company ueA u� 44 LL �Com.L Office Phone_(- t Oq, Fax l 0
e"c
Co.Address: City State Zip
License Holder(Print): C�F�1`�i - �C�l l�b—�V 1 State Certification/Registration#CC
Notarized Signature of License Holder
CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
j X ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
MECHANICAL HVAC PERMIT
MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814
JOB INFORMATION:
Job ID: 14-MECH-453
Job Type: MECHANICAL HVAC ONLY
Description: 1 cu 1 ahu 2.5 tons
Estimated Value:
Issue Date: 11/18/2014
Expiration Date: 5/17/2015
PROPERTY ADDRESS:
Address: 440 OCEAN BLVD
RE Number: 170171-0000
PROPERTY OWNER:
Name: SNYDER, SCOTT
Address: 440 OCEAN BLVD
GENERAL CONTRACTOR INFORMATION:
Name: HAMMOND AIR CONDITIONING INC
Address: 3412 GALILEE RD QA DONALD E HAMMOND
Phone: - -
PERMIT INFORMATION: Sticker for overcurrent protection must be on A/C equipment prior to
inspection. Failure to comply will result in a failed inspection and reinspect fees. No
exceptions.
FEES:
Furnaces and Heating $24.00
AC and Refrigeration $20.00
State Mech DBPR Surcharge $2.00
State Mech DCA Surcharge $2.00
Trade Permit Base Fee $55.00
Total Payments: $103.00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904) 247-5826 Fax 904 247-5845
.TOB ADDRESS: � � ���� � � PERMIT #
PROJECT VALUE $ �D �c'� ARI# REQUIRE
Air Handling Equipment Only Air Handling Unit & on a ser Condenser Only
NEW AIR CONDITIONING & HEATING SYSTEM INSTA,LLATION
Air Conditioning: Unit Quantity_� Tons Per Unit =�
Heat: Unit Quantity�_ BTU's Per Unit Seer Rating ��
Duct Systems: Total CFM 0,0 REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
-FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
not. The permit does not give authority to vionlate th pr visions of any other state or local law regulation construction or the performance of construction.
Property Owners Name J ` l e Phone Number —31 115 5
Mechanical Company Ro,, n'1 L9 )�-.en' Office Phone7°11
318-0,
Co. Address: ,��� 12 Gam' ��' O c� City - K
54 W ti(1 e State Zi
' p�?Z�
License Holder(Print): State Certification/Registration c
Notarized Signature of License Holder
Before me this day of 20
Signature of Notary Public