Permit Roof 1661 N Linkside Ct 2014 It J I' ll CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD =" ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 ROOF PERMIT MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 14-ROOF-522 Job Type: ROOF PERMIT Description: REROOF FL 10124-R9 Estimated Value: $7,500.00 Issue Date: 12/1/2014 Expiration Date: 5/30/2015 PROPERTY ADDRESS: Address: 1661 N LINKSIDE CT RE Number: 172374-6175 PROPERTY OWNER: Name: FORD, ANDREW J Address: 1661 N LINKSIDE CT GENERAL CONTRACTOR INFORMATION: Name: BOSCO BUILDING CONTRACTORS Address: 2158 MAYPORT RD QA TODD ALBERT BOSCO Phone: - - FEES: BUILDING PERMIT FEE $87.50 STATE DCA SURCHARGE $2.00 PLAN CHECK FEES $43.75 STATE DBPR SURCHARGE $2.00 Total Payments: $135.25 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. BUILDING PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Road, Atlantic Beach, FL 32233 Office(904)247-5826 Fax(904)247-5845 Job Address: 1661 N Linkside CT Permit Number: 19 4 �PP-5 -Z. Legal Description 47-85 17-2S-29E Selva Linkside 2 Lot 115 Parcel# Floor Area of q. t. Sq.Ft Valuation of Work $ 7,500 _ Proposed Work heated/cooled 1374- non-heated/cooled-1629-- --- Class of Work(circle one): New Addition Alteration (]&D Move Demolition )ol/spa window/door Use of existing/proposed structure(s)(circle one): Commercial est tie If an existing structure,is a fire sprinklers stem in a ed7(Circle one es o Florida Product Approval# L- i � For multiple products use pro uct approve form' Describe in detail the type of work to be performed: Re-Roof Property Owner Information: Name: Andrew J. Ford Address: 1661 N Linkside Ct City Atlantic Beach State FL Zip 32233 Phone E-Mail or Fax#(Optional) Contractor Information: Company Name: Justin Larsen Construction, Inc. Qualifying Agent: Justin E. Larsen Address: 4670 Hedgehog St City Middleburg State FL Zip 32068 Office Phone 904-241-0320 Job Site/Contact Number 904-241-0320 Fax#904-241-0326 State Certification/Registration# CCC 1329847 Architect Name&Phone# Engineer's Name&Phone# Fee Simple Title Holder Name and Address Bonding Company Name and Address Mortgage Lender Name and Address Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or Installation has commenced prior to the issuance of a permit and that all work wlll be pe ornred to meet the standards of all laws regulating construction In this jurisdiction. This permit becomes null and u�id jwork is rat commenced within six(6J�months,or if construction or work is suspended or abandoned jor a period of six(6)months at any time after work is commenced I understand that separate permits must be secured for EJectricat Work, Plumbing,Signs, Wells,Pools,Fwrnaces,Boilers,Heaters, Tanks and AJr Conditioners,ac WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YO11R NOTICE OF COMMENCEMENT. I hereby certify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type o Oork will be complied with whether specified herein or not. The granting of a permit does not presume to give authori to violate or cancel the provisions of any other federal.state.or loc !law regulating construction or the performance of construction. $ignatuie of:Owner /l G G1 Signature of Contractor Print Name 11�t f rd Print Name _..,'.la...fin. A�.---..._ ...,....... ___. _ _ .........__._...._. 7 ...._....w _ _ _ Larse Sworn to and subs o€e Sworn to and subscribed before me this j Q_D of MMY K M this _t" Day of a Iv WILLIAM t2BOPE '•l "i _lSSION*FF104105 Notary Public,State ot Florida Notary Publ ,°�!` ` Notary`" c `► M}Comm Fxpires Oct.19.2015 �,o� ,ss FloridaNOtaryService.com ry Commission No.EE 128745 Revised 01.26.10 NOTICE OF COMMENCEMENT (PREPARE IN DUPLICATE) Permit No, Tax Folio No. State of FWRIDA County of DUVAL To whom It may concern: The undersigned hereby informs you that Improvements will be made to certain real property,and In accordance with Section 713 of the Florida Statutes,the following Information is stated in this NOTICE OF COMMENCEMENT. Legal description of property being improved: 47-85 17-2S-29E SELVA LINKSIDE UNIT 2 04772 Address of property being improved: 1661 N LINKBIDE CT-ATLANTIC BEACH,FL 32233 General description of improvements: RE-ROOF Owner ANDREW J FORD Address 1661 N LINKSIDE CT.-ATLANTIC BEACH,FL 32233 Owner's interest In site of the Improvement GENERAL Fee Simple Titleholder(if other than owner) Name Address Contractor JUSTIN LARSEN CONSTRUCTION,INC Address 4670 HMISEHOG SP-IvIIDDLEBURG,FL 32068 Phone No.904-241-0320 Fax No"904-241-0326 Surety(If any) Address Amount of bond$ Phone No. Fax No. Name and address of any person making a loan for the construction of the Improvements. Name Address Phone No. Fax No. Name of person within the State of Florida,other than himself,designated by owner upon whom notices or other documents may be served: Name Address Phone No. Fax No. In addition to himself,owner designates the following person to receive a copy of the Lienor's Notice as provided in Section 713.06(2)(b),Florida Statutes.(Fill in at Owner's option). Name Address Phone No. Fax No. Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY NER I) Signed. J� DATE J 1 C,�r 1 Before thin ay f r the County or Duval St at ridaa personalty appeared Doe#2014262098,OR BK 1698'E Page 18'I 2, himself/herself and afb s that all statements and declarations herein in by Number Pages: 1 are true and accura P _ Recorded 11119,%2014 at 04:26 PM, TAMMY K MANNING L&I"Ronnie Fussefi CLE RK CIRCUIT COURT DUV�L MY COMMISSION*FF104105COUNTY i RECORDING$10.00 EXPIRES A ril 3 2018 Notary Public at My commission ex Lar W -ef59---Flo.I �t�obe7 oice.cnm- ry Personally Known or Produced IdentiGCailon EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 TRINITY ERD 353 CHRISTIAN XFORD, CT STREET, UNIT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 EVALUATION REPORT GAF Evaluation Report 01506.01.08-1111 1361 Alps Road, Building 7-3 FL10124-119 Wayne, NJ 07470 Date of Issuance: 01/03/2008 Revision 11: 02/26/2013 SCOPE: This Evaluation Report is issued under Rule 9N-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been designed to comply with the 2010 Florida Building Code sections noted herein. DESCRIPTION: GAF Asphalt Roof Shingles LABELING: Each unit shall bear labeling in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinityiERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 5. Prepared by: The facsimile seal appearing was authorized 5-. -A-s p}•;L4, by Robert Nieminen,P.E.on 02/26/2013 r= t f== This does not serve as an electronically signed Robert J.M. Nieminen, P.E. F •.... document. Signed,sealed hardcopies have been •.,s ,��- ?aL,;++` transmitted to the Product Approval Administrator and Florida Registration No. 59166, Florida DCA ANE1983 to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinityiERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. TrinityiERD is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. Q)'TRINI-ry ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/ Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2007 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161, Class F 2006 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158, Class H 2007 1507.2.7.1, R905.2.6.1 Wind Resistance TAS 107 1995 3. REFERENCES: Entity Examination Reference Date GAF(PDM 1915) Letter of Equivalency Seal-A-Ridge Impact Resistant IR 01/13/2012 PRI (TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004 PRI (TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005 PRI (TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013 UL(TST 1740) ASTM D3462 93NK6295 11/29/1993 UL(TST 1740) ASTM D3462 99NK43835 01/12/2000 UL(TST 1740) TAS 107 94NK9632 03/29/2000 UL(TST 1740) ASTM D3462 OINK06632 02/02/2001 UL(TST 1740) ASTM D3161,TAS 107 OINK9226 05/21/2001 UL(TST 1740) ASTM D3161 01NK37122 12/18/2001 UL(TST 1740) ASTM D3462 01NK37122 12/19/2001 UL(TST 1740) ASTM D3161,TAS 107 02NK12980 04/10/2002 UL(TST 1740) ASTM D3161,TAS 107 02NK30871 09/09/2002 UL(TST 1740) ASTM D3161 03CA5367 03/11/2003 UL(TST 1740) ASTM D3462 03NK26444 10/17/2003 UL(TST 1740) ASTM D3462 04NK13850 06/07/2004 UL(TST 1740) ASTM D3161 04NK13850 06/23/2004 UL(TST 1740) ASTM D3161 04NK30546 03/10/2005 UL(TST 1740) ASTM D3462 04NK22009 05/06/2005 UL(TST 1740) ASTM D3161 04NK22009 05/09/2005 UL(TST 1740) ASTM D3462 05NK27924 02/10/2006 UL(TST 1740) ASTM D3161 05NK27924 02/11/2006 UL(TST 1740) ASTM D3161, D3462 06CA18077 06/05/2006 UL(TST 1740) ASTM D3161, D3462 06CA18074 06/16/2006 UL(TST 1740) ASTM D3161, D3462 06CA35251 10/18/2006 UL(TST 1740) ASTM D3462 06CA31603 12/01/2006 UL(TST 1740) ASTM D3161, D3462 06CA41095 12/27/2006 UL(TST 1740) ASTM D3161 07NK05228 03/13/2007 UL(TST 1740) ASTM D3161 06CA31611 04/04/2007 UL(TST 1740) ASTM D3161 06CA61148 04/09/2007 UL(TST 1740) ASTM D3161, D3462 07CA31742 11/08/2007 UL(TST 1740) ASTM D3161, D7158, D3462 08CA06100 03/13/2008 UL(TST 1740) ASTM D3161, D3462 07CA55908 04/01/2008 UL(TST 1740) ASTM D3161, D3462 09CA10592 03/26/2009 UL(TST 1740) ASTM D3161, D3462 09CA06856 05/15/2009 UL(TST 1740) ASTM D3161, D7158, D3462 09NK06647 08/01/2009 UL(TST 1740) ASTM D3161, D7158, D3462 09CA27281 08/27/2009 UL(TST 1740) ASTM D3161, D7158, D3462 10CA35554 03/05/2010 UL(TST 1740) ASTM D3161, D7158, D3462 10CA13686 05/15/2010 UL(TST 1740) ASTM D3462 1OCA07264 05/27/2010 UL(TST 1740) ASTM D3462 10CA11953 10/29/2010 UL(TST 1740) ASTM D3161, D7158, D3462 10NK11951 10/30/2010 UL(TST 1740) ASTM D3161, D7158, D3462 10NK12070 11/04/2010 UL(TST 1740) ASTM D3161, D7158, D3462 08CA06100 01/30/2010 Exterior Research and Design, LLC. Evaluation Report 01506.01.08-Ril Certificate of Authorization#9503 FL10124-R9 Revision 11: 02/26/2013 Page 2 of 5 TRINITY ERD Entity Examination Reference Date UL(TST 1740) ASTM D3161, D7158, D3462 IOCA53934 03/31/2011 UL(TST 1740) ASTM D3161, D7158, D3462 11CA48924 10/22/2011 UL(TST 1740) ASTM D3161, D7158, D3462 11CA47919 12/03/2011 UL(TST 1740) ASTM D3161, D7158, D3462 11CA48408 12/08/2011 UL(TST 1740) ASTM D3161, D7158, D3462 11CA48725 12/09/2011 UL, LLC. (TST 9628) ASTM D3462 12CA34891 10/12/2012 UL, LLC. (TST 9628) ASTM D3161, D7158, D3462 12CA58151 02/15/2013 UL, LLC. (QUA 9625) Quality Control Inspection Report, File No. R21 08/08/2012 UL, LLC. (QUA 9625) Quality Control R3915 Current 4. PRODUCT DESCRIPTION: 4.1 Marquis WeatherMax, Royal Sovereign and Sentinel are a fiberglass reinforced, 3-tab asphalt roof shingles. 4.2 Camelot, Camelot II / Camelot 30, Capstone, Country Mansion, Country Mansion II, Grand Canyon, Grand Sequoia, Grand Sequoia IR, Grand Slate, Grand Slate II, Monaco, Sienna, Timberline American Harvest, Timberline ArmorShield II, Timberline Natural Shadow, Timberline Natural Shadow Arctic White, Timberline HD / Timberline Prestique 30, Timberline Prestique 40 / Timberline Cool Series, Timberline Ultra HD / Timberline Prestique Lifetime, Timberline Majestic / Timberline Majestic 30 and Woodland are fiberglass reinforced, laminated asphalt roof shingles. 4.3 Slateline is a fiberglass reinforced, 5-tab asphalt roof shingle. 4.4 Seal-A-Ridge, Seal-A-Ridge Armorshield, Seal-A-Ridge IR, Ridglass 8, Ridglass 10, Ridglass 12 and Timbertex Hip and Ridge are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.5 ProStart Starter Strip Shingles and WeatherBlocker Starter Strip Shingles are a starter strips for asphalt roof shingles. 5. LIMITATIONS: 5.1 This Evaluation Report is not for use in the HVHZ. 5.2 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.3 Wind Classification: 5.3.1 All GAF shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for us in all wind zones up to Vasd = 150 mph (V,it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.3.2 All GAF hip & ridge shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for us in all wind zones up to Vasd = 150 mph (V„it = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.3.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 9N-3. Exterior Research and Design, LLC. Evaluation Report 01506.01.08-R11 Certificate of Authorization#9503 FL10124-R9 Revision 11: 02/26/2013 Page 3 of 5 TRINITY ERD 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 9N-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Starter Shingles: 6.2.1 Installation of ProStart Starter Strip Shingles and WeatherBlocker Starter Strip Shingles shall comply with the manufacturer's current published instructions. 6.3 Asphalt Shingles: 6.3.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: ➢ Camelot, Camelot II / Camelot 30, Grand Slate II, Country Mansion II, Monaco and Woodland require minimum five (5) fasteners per shingle 6.3.2 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the shingle manufacturer for details. 6.4 Hip & Ridge Shingles: 6.4.1 Installation of Ridglass 8, Ridglass 10 and Ridglass 12 asphalt shingles shall comply with the manufacturer's current published instructions with a minimum two (2) nails per side [total of four (4) nails per shingle] and asphalt roofing cement. 6.4.2 Installation of Seal-A-Ridge, Seal-A-Ridge Armorshield and Seal-A-Ridge IR asphalt shingles shall comply with the manufacturer's current published instructions with a minimum two (2) nails per shingle. 6.4.3 Installation of Timbertex Hip and Ridge asphalt shingles shall comply with the manufacturer's current published instructions with a minimum two (2) nails per shingle and beads of Sonneborn NP1 Gun Grade Polyurethane Sealant or Henkel PL Roofing and Flashing Sealant. 6.4.4 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 7. LABELING: 7.1 Each unit shall bear a permanent label with the manufacturer's name, logo, city, state and logo of the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. Exterior Research and Design, LLC. Evaluation Report 01506.01.08-R11 Certificate of Authorization#9503 FL10124-R9 Revision 11: 02/26/2013 Page 4 of 5 TRINITY ERD 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC — QUA9625; (847) 664-3281 - END OF EVALUATION REPORT - I Exterior Research and Design, LLC. Evaluation Report 01506.01.08-1111 Certificate of Authorization#9503 FL10124-119 Revision 11: 02/26/2013 Page 5 of 5