426 SKATE RD MECH IS
CITY OF ATLANTIC BEACH
' 800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
fC INSPECTION PHONE LINE 247-5814
MECHANICAL HVAC PERMIT
MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814
JOB INFORMATION:
Job ID: 14-MECH-686
Job Type: MECHANICAL HVAC ONLY
Description: 1 cu 1 ahu
Estimated Value:
Issue Date: 12/22/2014
Expiration Date: 6/20/2015
PROPERTY ADDRESS:
Address: 426 SKATE RD
RE Number: 171559-0000
PROPERTY OWNER:
Name: HARDY, JOSEPH MCDANIEL
Address: PO BOX 331514
GENERAL CONTRACTOR INFORMATION:
Name: DONOVAN HEATING &AIR
Address: 315 SIXTH AVENUES QA WILLIAM J DONOVAN
Phone: - -
PERMIT INFORMATION: Sticker for overcurrent protection must be on A/C equipment prior to
inspection. Failure to comply will result in a failed inspection and reinspect fees. No
exceptions.
FEES:
Furnaces and Heating $24.00
AC and Refrigeration $16.00
State Mech DBPR Surcharge $2.00
State Mech DCA Surcharge $2.00
Trade Permit Base Fee $55.00
Total Payments: $99.00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph (904) 247-55826 Fax (904) 247-5845
10B ADDRESS: A7-& SKK-rc KCk PERMIT#
PROJECT VALUE $ 3�oARI# '�6-1 3-7 91 REQUIRED
Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only
NEW AIR CONDITIONING & "EATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity i BTU's Per Unit _ Seer Rating HIS
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIIlONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity 1 Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
# Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read
its application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
ot. The permit does not give authority to violate the p�ro�visions of any other state or local law regulation construction or the performance of construction.
Property Owners Name �%a�'►! Phone Number
Mechanical Company "Jel n Nee d Office Phone 2 1.�7 Fax oo i 3-7 .-
Co. Address: 31S b Ut 5 City ,oar �� State rt Zip3-n
License Holder (Print): .� State Certification/Registration# C4 �6/
Notarized Signature of License Holder
;iRti'N54',, RICHi,RD',N APIKINS Before me this day 20
_.; :.. Comn�iss;on I:Fr 040399 i
Expires Jdy 29,2017 Signature of Notary Public l
''•q,$a\ �
Bonded'�,�❑ °„.o mut,nee 900-396-1019
Project Summa Job:
wrightsoft 1. Date: December 19,2014
Entire House By: Aaron Thacker
Donovan Heat&Air
315 6th Ave S,Jacksonville Beach,FL 32250 Phone:904241-3785 Fax:904-241-3745 Email:aaron@donovanac.com Web:wwwDonovanAC.com
Project • •
For: Joe McDaniel
426 Skate Rd,Atlantic Beach, FL 32233
Notes:
D- • • •
Weather: Jacksonville Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 39 OF Outside db 99 OF
Inside db 70 OF Inside db 75 OF
Design TD 31 OF Design TD 24 OF
Daily range L
Relative humidity 50 %
Moisture difference 69 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 10754 Btuh Structure 9911 Btuh
Ducts 1856 Btuh Ducts 3243 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 12610 Btuh Use manufacturer's data n
Rate/swing multiplier 1.04
Infiltration Equipment sensible load 13680 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 2241 Btuh
Ducts 917 Btuh
Heating Cooling Central vent (0 cfm) 0 Btuh
Area (ft') 1140 1140 Equipment latent load 3158 Btuh
Volume (ft') 9120 9120
Air changes/hour 0.45 0.23 Equipment total load 16838 Btuh
Equiv.AVF (cfm) 68 35 Req. total capacity at 0.70 SHR 1.6 ton
Heating Equipment Summary Cooling Equipment Summary
Make Tempstar Make Tempstar
Trade 14 SEER N SERIES R410A HP Trade 14 SEER N SERIES R410A HP
Model N4H424A(G)KB' Cond N4H424A(G)KB'
AHRI ref no3693796 Coil FEM4P24"A'++TXV
AH R I ref no3693796
Efficiency 8.2 HSPF Efficiency 12.0 EER, 14.5 SEER
Heating input Sensible cooling 15960 Btuh
Heating output 24000 Btuh @ 47'F Latent cooling 6840 Btuh
Temperature rise 29 OF Total cooling 22800 Btuh
Actual air flow 760 cfm Actual air flow 760 cfm
Air flow factor 0.060 cfm/Btuh Air flow factor 0.058 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.81
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
+ wrightsoft
2014-Dec-19 1ae l
Right-Suite®Universal 8.0.24 RSU05995 Pagel
1
ACh` C:UJsers\Owner\Documents\WrightsoftHVAC\Bogus2ton.rup Calc=MJ8 FrontDoorfaces-W
•