Loading...
426 SKATE RD MECH IS CITY OF ATLANTIC BEACH ' 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 fC INSPECTION PHONE LINE 247-5814 MECHANICAL HVAC PERMIT MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 14-MECH-686 Job Type: MECHANICAL HVAC ONLY Description: 1 cu 1 ahu Estimated Value: Issue Date: 12/22/2014 Expiration Date: 6/20/2015 PROPERTY ADDRESS: Address: 426 SKATE RD RE Number: 171559-0000 PROPERTY OWNER: Name: HARDY, JOSEPH MCDANIEL Address: PO BOX 331514 GENERAL CONTRACTOR INFORMATION: Name: DONOVAN HEATING &AIR Address: 315 SIXTH AVENUES QA WILLIAM J DONOVAN Phone: - - PERMIT INFORMATION: Sticker for overcurrent protection must be on A/C equipment prior to inspection. Failure to comply will result in a failed inspection and reinspect fees. No exceptions. FEES: Furnaces and Heating $24.00 AC and Refrigeration $16.00 State Mech DBPR Surcharge $2.00 State Mech DCA Surcharge $2.00 Trade Permit Base Fee $55.00 Total Payments: $99.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-55826 Fax (904) 247-5845 10B ADDRESS: A7-& SKK-rc KCk PERMIT# PROJECT VALUE $ 3�oARI# '�6-1 3-7 91 REQUIRED Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & "EATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity i BTU's Per Unit _ Seer Rating HIS Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIIlONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity 1 Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read its application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to violate the p�ro�visions of any other state or local law regulation construction or the performance of construction. Property Owners Name �%a�'►! Phone Number Mechanical Company "Jel n Nee d Office Phone 2 1.�7 Fax oo i 3-7 .- Co. Address: 31S b Ut 5 City ,oar �� State rt Zip3-n License Holder (Print): .� State Certification/Registration# C4 �6/ Notarized Signature of License Holder ;iRti'N54',, RICHi,RD',N APIKINS Before me this day 20 _.; :.. Comn�iss;on I:Fr 040399 i Expires Jdy 29,2017 Signature of Notary Public l ''•q,$a\ � Bonded'�,�❑ °„.o mut,nee 900-396-1019 Project Summa Job: wrightsoft 1. Date: December 19,2014 Entire House By: Aaron Thacker Donovan Heat&Air 315 6th Ave S,Jacksonville Beach,FL 32250 Phone:904241-3785 Fax:904-241-3745 Email:aaron@donovanac.com Web:wwwDonovanAC.com Project • • For: Joe McDaniel 426 Skate Rd,Atlantic Beach, FL 32233 Notes: D- • • • Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 OF Outside db 99 OF Inside db 70 OF Inside db 75 OF Design TD 31 OF Design TD 24 OF Daily range L Relative humidity 50 % Moisture difference 69 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 10754 Btuh Structure 9911 Btuh Ducts 1856 Btuh Ducts 3243 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 12610 Btuh Use manufacturer's data n Rate/swing multiplier 1.04 Infiltration Equipment sensible load 13680 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2241 Btuh Ducts 917 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft') 1140 1140 Equipment latent load 3158 Btuh Volume (ft') 9120 9120 Air changes/hour 0.45 0.23 Equipment total load 16838 Btuh Equiv.AVF (cfm) 68 35 Req. total capacity at 0.70 SHR 1.6 ton Heating Equipment Summary Cooling Equipment Summary Make Tempstar Make Tempstar Trade 14 SEER N SERIES R410A HP Trade 14 SEER N SERIES R410A HP Model N4H424A(G)KB' Cond N4H424A(G)KB' AHRI ref no3693796 Coil FEM4P24"A'++TXV AH R I ref no3693796 Efficiency 8.2 HSPF Efficiency 12.0 EER, 14.5 SEER Heating input Sensible cooling 15960 Btuh Heating output 24000 Btuh @ 47'F Latent cooling 6840 Btuh Temperature rise 29 OF Total cooling 22800 Btuh Actual air flow 760 cfm Actual air flow 760 cfm Air flow factor 0.060 cfm/Btuh Air flow factor 0.058 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. + wrightsoft 2014-Dec-19 1ae l Right-Suite®Universal 8.0.24 RSU05995 Pagel 1 ACh` C:UJsers\Owner\Documents\WrightsoftHVAC\Bogus2ton.rup Calc=MJ8 FrontDoorfaces-W •