Loading...
355 6TH ST REMODEL y�J�l �� ��' CITY OF ATLANTIC BEACH H s) 800 SEMINOLE ROAD J "~ ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 46M9" RESIDENTIAL ADDITION MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 ]OB INFORMATION: Job ID: 14-RADD-435 Job Type: RESIDENTIAL ADDITION Description: remodel addition Estimated Value: $150,000.00 Issue Date: 12/5/2014 Expiration Date: 6/3/2015 PROPERTY ADDRESS: Address: 355 6TH ST RE Number: 169898-0000 PROPERTY OWNER: Name: HUNTER, MAUREEN E Address: 2747 FALCON VIEW CT GENERAL CONTRACTOR INFORMATION: Name: BOSCO BUILDING CONTRACTORS Address: 2158 MAYPORT RD QA TODD ALBERT BOSCO Phone: - - PERMIT INFORMATION: PUBLIC WORKS: All runoff must remain on-site. Cannot raise lot elevation without measures to retain runoff. If on-site storage is required, a post construction topographic survey documenting proper construction will be required. Full right-of-way restoration, including sod, is required. FEES: PLAN CHECK FEES $315.00 BUILDING PERMIT FEE $630.00 STATE DCA SURCHARGE $9.45 STATE DBPR SURCHARGE $9.45 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. Lot 24,Block 8,ATLANTIC BEACH according to the Plat thereof,as recorded in Plat Book 5,Page 69,of the Public Records of DUVAL County,Florida. Community Number:120075 Panel:0001 Suffix:D Flood Zone:X Field Work:8i25009 Certified To: BENJAMIN C.AND MAUREEN E.HUNTER;SUNSHINE TITLE CORPORATION;CHICAGO TITLE; Property Address: 355 6TH AVENUE ATLANTIC BEACH,FL 32233 Survey Number:152665 ' r Lcf tj NOV 2 5 `014 ass By LEGM.. AC AffC0AVRx11ERf AtE L4AFAAMV SVVJX FASFIENT MW WIT OIFWAY BA WARMR9WWWX XX 607Aq aCYA77ON OR OfF#;A4L RECOOWSLR TARCINR�TA CAP AN B�Aftw 01E FF A DRODIR OAR OF m Waaws OAK P.P. PON4]4PKXE F.LP. FO AIV RONPrE M u7X/TY64Sakis17 T.O.bt 70P OF"W (Cf CALC(WED M fOlAV P.CP, f4FJArf0WCGNT)ap W WA W47ERAETR CATV C KEROW ® *RL PAN PBWVAEWTADMM FA11pVI,W19VT PGt PAGE CA C4TWA44ri wa WAESSCaWSR T.BAC ngA1cR4RYAEAXYfApm t7'1 PLAT DX DIRA[L N" FPK fUWPAft9?,W0NAkt RL IE'7ROAFFAMM S PA PLAT$" DZ DR40"E49EAENT F.CAA AX W Gaya 7FA CAUENT P.QB. POW OFSEG1111 W LCP UIXITYI�CE Lbw DIR/YEMY L IBB IPDWAIGI7 A0.0 PIAAITTQFO 64C[AApIT p1V FELDAFWRM A C+BVMAL AWWiI6ar TA LAE WM PCC PCbV Of CO FO W CUQYATL4W AF- AAlCY1Q48*VN 7VT C.M. 03VCW7EA�YENf L/0/BJACCE 54s9 qvT PC AWO1FOUlA1 nff 049MwVn 1TYLM D.B DEED 9" AIR A0V#AX 4MCfb4 T PAC P0hTQFRFMTSFCLRVAnM l PR PBzTYLIIE D. DESCAFROVORDEED FA FaWAKI P.T. AWOIFTAN09ACY CN CHOW E-WT E4980VT MAD ARE A DW • PlWPERTYCORNER Q � EOW. WWC1FWA7ER ACR AUNlE4LxAI WE Roof019#MNGEAfAgNr AIT.& AVT 70XWE R R4alASfR40W) 11-IJ- W7ODAW`' -X-X WAIL PHYCE PAGE 1 OF 2 PAGES LEGAL DESCRIPTION AND CERTIFICATION iJ "AL LaES+gMI 7m AMOvmw BY orms'd LB#46136 z1 7WW""IbWMW WNEIWX0rAB:STRACWR71IR64SSeMOROTHER iM4NGUA47TSHDNNFO N114n T. L11OiEt 3j 0Q(,/VDigR7/A1tSAFf;:J071►CA,Sf{X�ITIC41(SQ407}A9RA1MAlEJVTSNIIZE AVTLOCA ED TARGET w4u TAESARE W RE FAM Of TME WALL AAD AW AVT TO BE UM W iiW A Mrr Wy 1[ �' ��. BOL#9XRYLAIE£ SM I N 00d Y MMLE 6OD?040ftu S LOG47W WWWANSW""AREPuTaWAFAAWOat WoTNq"W&V a SERVING MOST FLORIDA COUNTIES IJ i�ONAPAR7TLiE7E/AINAB7. e �� 4N>�FTAAD CBAL D7t7NQV0. fA?9 6WiCORPORATE WAY SUITE210 9I AVBCaIEWTAW"WAFWWMR% TA"OM/A4LPA4Fov"4Q;8MWIt7AKXaE WEST PALM fXf�iRYl1lASTRATfIffiA7701 °3dE7Y1£flYP/IIBfC+1[�TSA10WLOTLMs P FL39407 WALL C4*"SS�.%Wj CayMa TAF L OCA MY OF TW MFgo4�E FKM 014`R (w)bob 4800 ���T� FACSIMILE (861)640-0674 STATEWIDE PHONE (800)2264807 STATEWIDE FACSIMILE (800)741-0676 BUILDING PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Road,Atlantic Beach,FL 3, 3 Office(904)247-5826 Fax(904)247-' 5 Job Address: 355 6th Street Atlantic Beach FL 32233 Per. 't Number: Legal Description 569 16-2S-29E 17 03101 Atlantic Beach Parcel: Floor Area of Sq.Ft. r Sq.Ft Valuation of Work$ M4 Proposed Work heated/cooled non-heated/cooled Class of Work(circle one): Neta Addition Alteration Repair Move 1.. o ition poollspa urindou;door Use of existing/proposed structure(s)(circle one): Commercial Resident -�� � If an existing structure,is a fire sprinkler system installed?(Circle one): Yes N/A Florida Product Approval# For multiple products use product approve arm Describe in detail the type of work to he performed:Addition and Remodel NO Property Owner Information: e. ,.. S Name:_ Kathervn Dalftleish/William If.Brigman Address:355 61h ST Ciri Atlantic Beach State: FL 'Lip: 32233 Phone E-Mail or Fax#(Optional) Contractor Information: Company Name:Bosco Building Contractors Inc Qualifying Agent:Tc, . i3osco Address:2158 Mavpgrt Rd City Atlas is BeseState F L—Zip Office Phone 904-241-0320 Job Site/Contact Number 904-24 1 ' .20 Fax#904-241-0326233 State Certification/Registration# CBC 1250212 Architect Name&Phone# Engineer's Name&Phone# Fee Simple Title I lolder Name and Address Bonding Company Name and Address Mortgage Lender Name and Address — Application is hereby made to obtain a permit to do the work and installations as indicated !certrfi•that n rk or installation has commenced pnor to If issuance of a rinit and that a!/work will be performed to meet the standards of a!1 laws regulating cun4*Or a this jurisdiction. This becomes troll and vad work is not commenced within s4v(6)months,or rf construction or work is suspended or auction i d or a is iod ofsiti(6)months at arty time after work is commenced /understand that separate permits must be secured for ElerfiiCat Rork,piyttidittg y ,� �j., p�F)monis Batters,orates,Tank mdAirConAdonm,ac. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.IF YOU INTEND TO OBTAIN FINANCING CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YO�JR NOTICE OF COMMENCEMENT. hereby certify that I have trod and examined this appb'cation ardknow the same to be true and correct.:,1l ;inions of laws and ordinances governingt this tyfi of work will be complied with whether specified herein or not. The granting o a the provisions of any otherfederal state flaw regulating construction or the pe f tma�ice it fcnrnsOrrk, <me to give auf rity to violate or carne! i Signature of Owner Signature of Cotitra�, ' Print Name r flut `V>/ ..•._ .... :.._.___.__.____. 1(J Print Name , _..._M, ,¢_._ 1D.1c�..___..____...__.._..._.._........ Sworn to and subscribed before me this,;, Dav of c Y-ir: d. 20/✓ Sworn to and subscrii afore me this 4!: L.Day of�, r-' .20/y Nota'tY Public WILLIAM L.POPE — otary Vublic Notary Public,State of Florida MLLIA POPE My Comm.Expires Oct.19,2015 N "9@ state of Florida Commission No,EE 128745 My COMM.Expires Oct 19,201.5 Commission No.EE 128745 �s Comp. By: RLC Date: 11/12/2014 Public Works Department City of Atlantic Beach Permit No: Pre-Dev Address: 355 6th Street Required Storage Volume Criteria: Section 24-66 of the City of Atlantic Beach's Zoning, Subdivsion, and Land Development Regulations requires that the difference between the pre-and postdevelopment volume of stormwawter runoff be stored on site. Volume of Runoff is defined as follows: V=CAR/12 Where: V=Volume of Runoff C= Coefficient of Runoff A=Area of lot in square feet R=25-yr/24-hr rainfall depth(9.3-inches for Atlantic Beach) Predeveloament Runoff Volume: Lot Area(A) = 7,500 ft' 392 11th St Lot 43 Runoff Coefficient Area Lot Arp- Description (ft2) Wtd "C" Impervious 1,420 7.00 0.19 Pervious 6, 20 0.16 (C)= 0.35 Runoff Volume / V= 0.35 V ;00 x 9.3 / 12 V= 2,043 Postdeveloament Runoff Volume, Lot Area(A) = 7 Runoff Coefficient Area Lot Area Description (ft) (ft2) "C" Wtd "C" Impervious 2,476 7,500 1.00 0.33 ISA = 33,0% Pervious 5,024 7,500 0.20 0.13 Runoff Coefficient(C)= 0.46 Runoff Volume V= 0.46 x 7,500 x 9.3 / 12 V= 2,698 ft3 Required Storage Volume DV= Postdevelopment Runoff Volume- Predevelopment Runoff Volume DV= 2,698 2,043 DV= 655 ft3 355 355 6th Street-onsite Retention w-grnd(2) 11/12/2014 S; Comp. By: RLC Date: 11/12/2014 Public Works Department City of Atlantic Beach Permit No: Pre-Dev Address: 355 6th Street Provided Storage: Elevation Area Storage (ft) (ft) (ft) 0.0 320 0 BOTTOM 16' x 20' 0,5 572 223 TOB 22'x 26' Elevation Area Storage (ft) (ft2) (ft) 0.0 0 0 BOTTOM 0,5 0 0 TOB Elevation Area Storage (ft) (ft2) (ft3) 0.0 0 0 BOTTOM 0 5 0 0 TOB Inground storage=A*d*pf A=Area= 572.0 d=depth to ESHWT= 3.0 pf=pore factor= 0.3 Inground Storage= 514.8 ft3 Required Treatment Volume= 655 ft3 Supplied Treatment Volume= 738 ft3 355 355 6th Street-onsite Retention w-grnd(2) 11/12/2014 i Brigman Addition 355 6th St Atlantic Beach HVAC Load Calculations for Bosco Custom Homes RHVACRE6JDENTIAL HVAC LOADS Prepared By: Jason McDuffie Home Energy Services 2060 Davis Rd, Jacksonville, FL 32218 904 757-3569 Wednesday, October 15, 2014 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Elite Software Development,Inc. Rhvac-Residential&Light Commercial HVAC Loads Brigman Addition 355 6th St Atlantic Beach Home Energy Services Page 2 Jacksonville,FL 32218 j Project Report en 1 Prosect Information s Project Title - Pro Briman Addition 3556th St Atlantic Bea l _ � gch Designed By: Alexa Laughren Project Date: Wednesday, October 15, 2014 Project Comment: This equipment can be replaced in name or by equal or greater SEER or HSFP as stated on the FL. Energy Code Client Name: Bosco Custom Homes Company Name: Home Energy Services Company Representative: Jason McDuffie Company Address: 2060 Davis Rd. Company City: Jacksonville, FL 32218 Company Phone: 904 757-3569 Company E-Mail Address: ecalcs@hesjax.com Company Website: www.hesjax.com Company Comment: Reference City: Jacksonville, Florida Building Orientation: Front door faces South Daily Temperature Range: Medium Latitude: 30 Degrees Elevation: 26 ft. Altitude Factor: 0.999 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 32 29.92 n/a n/a 70 n/a Summer: 95 77 45% 50% 75 46 RZOOK Total Building Supply CFM: 1,245 CFM Per Square ft.: 0.951 Square ft. of Room Area: 1,310 Square ft. Per Ton: 518 Volume(ft3)of Cond. Space: 10,873 Total Heating Required Including Ventilation Air: 29,077 Btuh 29.077 MBW Total Sensible Gain: 27,371 Btuh 90 % Total Latent Gain: 2,980 Btuh 10 % Total Cooling Required Including Ventilation Air: 30,351 Btuh 2.53 Tons(Based On Sensible + Latent) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C\ .A136grnan Addition 355 6th St.rh9 Wednesday, October 15; 2014, 2 01 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Home Energy Services Brigman Addition 355 6th St Atlantic Beach Jacksonville,FL 32218 ow Page 3 Miscellaneous Report - - FSystem 1 1st Floor Outdoor Outdoor Outdoor Indoor Indoor Grains Input Data Dry Bulb Wet Bulb Rel.Hum Rel Hum Dry Bulb Difference __ Winter. ''1 29.92 n/a 70 n/a Summer. 77 V �U 7 46.43 Duct Sizing Inputs Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.01000 0.01000 Pressure Drop: 0.1000 in.wg./100 ft 0.1000 in.wg./100 ft. Minimum Velocity: 550 ft./min 450 ft./min Maximum Velocity: 600 ft./min 750 ft./min Minimum Height: 0 in 0 in. Maximum Height: 0 in 0 in. r Air Data Winter Summer Infiltration Specified: 0.250 AC/hr 0.250 AC/hr 45 CFM 45 CFM Infiltration Actual: 0.250 AC/hr 0.250 AC/hr Above Grade Volume: X 10.874 Cu.ft. X 10,874 Cu.ft. 2,719 Cu.ft./hr 2,719 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 45 CFM 45 CFM Total Building Ventilation: 0 CFM 0 CFM ---System 1--- Infiltration &Ventilation Sensible Gain Multiplier: 21.98 = (1.10 X 0.999 X 20.00 Summer Temp. Difference) Infiltration&Ventilation Latent Gain Multiplier: 31.54 = (0.68 X 0.999 X 46.43 Grains Difference) Infiltration&Ventilation Sensible Loss Multiplier: 41.76 = (1.10 X 0.999 X 38.00 Winter Temp. Difference) Winter Infiltration Specified: 0.250 AC/hr(45 CFM) Summer Infiltration Specified: 0.250 AC/hr(45 CFM) Duct Load Factor Scenarios for System 1 Attie Duct- _.[,a_ -Surface From'; [Na Type Description Location Ceiling Leakage Insulation Area MDM 1 Supply Main Attic 16B 009 6 354 No 1 Return Main Attic.: 16B 015 6 131 No C:1 ... Brigman Addition 355 6th St.rh9 Wednesday, October 15, 2014, 2:01 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Home Energy Services Brigman Addition 355 6th St Atlantic Beach Jacksonville,FL 32218 --------------- _ -- -- - - _-- -_.--_- ___- --_Pam_: LLoad Preview Report Sy Net ft.' Sen Lat Net' Sen SFlyts s Ac Duct, Scope Ton Ron Area Gain Gain Gain Loss CFM CFM CFM Size Building 2.53 518 1,310 27,371 2,980 30,351 29,077 588 1,245 1,245 i System 1 2.53 518 1,310 27,371 2,980 30,351 29,077 588 1245 1,245 20 Duct I atent 751 751 Zone 1 1,310 27,371 2,229 29,600 29,077 588 1245 1245 20 1-Foyer 52 1,524 137 1,661 2,739 55 69 69 1.6 2-BreakfasvKdchen 203 4,075 327 4,402 2,985 60 185 185 2-6 3-Living Room 195 5,354 836 6,190 4.287 87 244 244 3-6 4-Bath 2 49 1,022 49 1,071 1,015 21 46 46 1-4 5-Bedroom 3 121 3,042 80 3,122 2,012 41 138 138 2-6 6-Laundry 28 59 0 59 39 1 3 3 1--4 7-Master Bath 84 424 56 480 973 20 19 19 1.4 8-Bedroom 2 105 2,620 150 2,770 3,053 62 119 119 2-4 9-Hall 120 962 49 1 D 11 1,442 29 44 44 1-4 10-Master Bedroom 216 3,742 210 3,952 4,649 94 170 170 2-6 11-Office 48 3,035 152 3,187 2,848 58 138 138 2-6 12-M Closet 90 1,513 183 1,696 3,034 61 69 69 1-6 C:\ . Brigman Addition 355 6th St.rh9 Wednesday, October 15, 2014, 2:01 PM Rhvac Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Nome Energy Services Brigman Addition 355 6th St Atlantic Beach 51 Jacksonville,FL 32218___ Pam _ _ --- --- Duct Size Preview Room orSource Mn murrr Maximum Rough Design SP Duct Duct Htg � qct. Duct Duct Name Velocity Velocity Factor U100 Loss Velocity Length Flow Flow Flow Sae System 1 Supply Runouts Zone 1 1-Foyer Built-In 450 750 0.01 0.1 508.4 55 69 1 5 2-Breakfast/Kftchen Built-In 450 750 0.01 0.1 472.2 60 185 24 3-Living Room Built-In 450 750 0.01 0.1 595.5 87_ 244 3-5 4-Bath 2 Built-In 450 750 0.01 0.1 532.8 21 _!, 46 1--4 5-Bedroom 3 Built-In 450 750 0.01 0.1 507.6 41 M 138 2-6 6-Laundry Built-In 450 750 0.01 0.1 30.6 1 3 1-4 7-Master Bath Built-In 450 750 0.01 0.1 220.9 20_ 19 1-4 8-Bedroom 2 Built-In 450 750 0.01 0.1 683 62 119 2-4 9-Hall Built-In 450 750 0.01 0.1 501.6 29_ 44 1-4 10-Master Bedroom Built-In 450 750 0.01 0.1 624.3 94_I 170 2-5 11-Office Built-In 450 750 0.01 0.1 506.4 58_ 138 2-5 12-M. Closet Built-In 450 750 0.01 0.1 504.8 61 _I 69 1-5 Other Ducts In System 1 Supply Main Trunk Built-In 550 600 0.01 0.1 570.8 588 1,245 20 _ Summary System 1 Heating Flow: 588 Cooling Flow: 1245 C:\ .. \Brigman Addition 355 6th St.rh9 Wednesday, October 15, 2014, 2:01 PM _ _ _ Residential- - g ---- -_ Rhvac- &Light Commercial HVAC Loads Elite Software Development,Inc. i Home Ener Services Bri man Addition 355 6th St Atlantic Beach Jacksonville,FL 32218 _ _ _age 6_ Total Building Summary Loads Lat Sen Tota Description Quan Loss G Po in _ Gain Gain J , 4A-6-o: Glazing-Double pane low-e (e = 0.20 or less), 151 4 1,8(17 0 3,113 3,113 high performance, operable window, e=0.05 on surface 2, any frame, u-value 0.33, SHGC 0.33 1OD-f: Glazing-French door, double pane low-e glass (e = 103.2 1,646 0 1,552 1,552 0.10), insulated fiberglass frame, u-value 0.42, SHGC 0.32 1D-cv-o: Glazing-Double pane, operable window, clear, 63.2 1,367 0 3,547 3,547 vinyl frame, u-value 0.57, SHGC 0.56 11J: Door-Metal- Fiberglass Core 34.8 794 0 648 648 12C-Osw: Wall-Frame, R-13 insulation in 2 x 4 stud 1343.6 4,648 0 3,238 3,238 cavity, no board insulation, siding finish, wood studs 1613-30: Roof/Ceiling-Under Attic with Insulation on Attic 1310 1,592 0 2,304 2,304 Floor(also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-30 insulation 22A-ph: Floor-Slab on grade, No edge insulation, no 206 10,630 0 0 0 insulation below floor, any floor cover, passive, heavy moist soil Subtotals for structure: 22,574 0 14,402 14,402 People: 4 800 920 1,720 Equipment: 0 6,100 6,100 Lighting: 0 0 0 Ductwork: 4,611 751 4,952 5,703 Infiltration: Winter CFM: 45, Summer CFM: 45 1,892 1,429 997 2,426 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Total Building Load Totals: 29,077 2,980 27,371 30,351 Total Building Supply CFM: 1,245 CFM Per Square ft.: 0.951 Square ft. of Room Area: 1,310 Square ft. Per Ton: 518 Volume(ft')of Cond. Space: 10,873 Total Heating Required Including Ventilation Air: 29,077 Btuh 29.077 MBH Total Sensible Gain: 27,371 Btuh 90 % Total Latent Gain: 2,980 Btuh 10 % Total Cooling Required Including Ventilation Air: 30,351 Btuh 2.53 Tons(Based On Sensible + Latent) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at yqur design conditions. I C \ \Briyrrnan Additir)rn :?'i5 F,th St rh9 Wednesday, (soder 15, 2014, 2 01 PM Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Home Energy Services Brigman Addition 355 6th St Atlantic Beach Jacksonville,FL 32218 ____-______-_ Page 7 Building Pie Chart Infiltration 7% Ductwork 16% Floor 37% Building Door 3% Loss 29,077 Btuh Glass 17% Roof 5% Wall 16% Roof 8% Infiltration 8% Wall 11% Ductwork 19% Building Gain 30,351 Btuh Glass 27% Equipment 20% Door 2% P �Peo le 6% CA - �\Brigman Addition 355 6th St.rhl4 Wednesday, October 15, 2014, 2 01 PM ential& ite Home Light Commercial HVAC Loads Brigman ft35are Devopment,Inc. 5 6thh St Atlantic Energy Services Addition Beach Jacksonville,FL 32218 __ Page 8 System 1 Room Load Summary Htg Min Run Run ag CI Min A&1 Room Area Sens Htg Duct Duct Sens Lat Clg Sys: No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM`! Zone 1 1 Foyer 52 2,739 55 1-5 508 1,524 137 69 69 2 Breakfast/Kitchen 203 2,985 60 2-6 472 4,075 327 185 185 3 Living Room 195 4,287 87 3-5 595 5,354 836 244 244 4 Bath 2 49 1,015 21 1-4 533 1,022 49 46 46 5 Bedroom 3 121 2,012 41 2-5 508 3,042 80 138 138 6 Laundry 28 39 1 1-4 31 59 0 3 3 7 Master Bath 84 973 20 1-4 221 424 56 19 19 8 Bedroom 2 105 3,053 62 2-4 683 2,620 150 119 119 9 Hall 120 1,442 29 1-4 502 962 49 44 44 10 Master Bedroom 216 4,649 94 2-5 624 3,742 210 170 170 11 Office 48 2,848 58 2-5 506 3,035 152 138 138 12 M. Closet 90 3,034 61 1-5 5_05 1_,5.13 183 69 69 Duct Latent 751 System 1 total 1,310 29,077 58.8 27,371 2,980_ 1,245 1,245 System 1 Main Trunk Size: 20 in. Velocity: 571 ft./min Loss per 100 ft.: 0.041 in.wg ling System Summary Cooling Sensible/Latent Sensible Latent Tota Tons Split Btuh Btuh Btuh Net Required 2.53 90% / 10% 27,371 2,980 30,351 Actual: 2.98 75%/25% 26,850 8,950 35,800 Equipment Data Heating System Cooling System Type: Air Source Heat Pump Air Source Heat Pump Model: 4TWR3036C1 4TWR3036C1 Indoor Model: 4TEC3F42C1 Brand: TRANE TRANE Description: Air Source Heat Pump Air Sou,.;e Heat Pump Efficiency: 7.7 HSPF 13 SEER Sound: 0 0 Capacity: 35,200 Btuh 35,800 Btuh Sensible Capacity: n/a 26,850 Btuh Latent Capacity: n/a 8,950 Btuh AHRI Reference No.: n/a 7117071 - i C:1 \Hmvrian Addition 35.5 (;Ih Si rh(a Wednesday, Octoher 15, 2014, 2 M FIM A1= 90'15'04" (M) A2= 89'44'56" (M) LOT 23 A3= 90'15'04" (M) BLOCK 8 A4= 89'44'56" (M) FOUND 1/2" FOUND 1/2" IRON PIPE \ IRON PIPE \ 0.0' 50.00' 0.2' —x o 0 O i II LOT 24 BLOCK 8 LOT 26 8 LOT 22- BLOCK 8 BLOCK 8 12 1' 12 2' 25.7 BUILDING CONCRETE ON o #355 o PROP. LINE ui ui M M 25.7' 12.2' 11 12.1' m a) cd M BLOCK FOUND 1/2" FOUND 1/2" CORNER IRON PIPE o N IRON PIPE \0 9sr P� f 550.00' i 50.00' 6 6th STREET (F) o SIXTH AVENUE (P) _ 40.0' R/W SURVEY NOTES CONCRETE DRIVE CROSSING PROPERTY BOUNDARY ON SOUTHERLY SIDE OF LOT THERE ARE FENCES NEAR THE BOUNDARY OF THE PROPERTY PAGE 2 OF 2 PAGES E 0 M c N BOUNDARY SURVEY LB#6135 y p l F r t C f9 A L Nc.2883 f r( -. T R Cv�T SURVEYORS CERTIFICATE SUR VEYIN■/q/ A W INC. c aI HEREBY CERTIFY THAT THIS BOUNDARY SURVEY n a IS A TRUE AND CORRECT REPRESENTATION OF A s = SURVEY PREPARED UNDER MY DIRECTION. s� sTnTeoc d NOTVALIDWITHOUTANAUTHENTICATED ELECTRONIC SERVING ALL FLORIDA COUNTIES �,y L O R I D P pa SIGNATURE AND AUTHENTICATED ELECTRONIC SEAL, q c g u R V, ORA RAISED EMBOSSED SEAL AND SIGNATURE. 5601 CORPORATE WAY SUITE 210 WEST PALM BEACH,FL 33407 PHONE (561)6404800 FACSIMILE (561)640-0576 (SIGNED) STATEWIDE PHONE (800)226AB07 CLYDE O.MCNEAL,PROFESSIONAL SURVEYOR AND MAPPER#2883 STATEWIDE FACSIMILE (800)741-0576 CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ,) �r ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 ELECTRICAL PERMIT MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 15-ELEC-119 Job Type: ELECTRIC ONLY Description: 35 SWITCHES Estimated Value: Issue Date: 1/27/2015 Expiration Date: 7/26/2015 PROPERTY ADDRESS: Address: 355 6TH ST RE Number: 169898-0000 PROPERTY OWNER: Name: HUNTER, MAUREEN E Address: 2747 FALCON VIEW CT GENERAL CONTRACTOR INFORMATION: Name: ERICKSON ELECTRICAL CONTRACTOR Address: 2807 ST JOHNS QA FRANK W ERICKSON Phone: - - FEES: State Elec DBPR Surcharge $2.00 State Elec DCA Surcharge $2.00 Switch Outlets $20.40 Trade Permit Base Fee $55.00 Total Payments: $79.40 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. ELECTRICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd,Atlantic Beach, FL 32233 Ph (904)247-5826 Fax 904) 247-5845 JOB ADDRESS: \ PERMIT# JEA INFORMATION REQUIRED ON ALL PERMITS _\5 t7 AMPS VOLTS PHASE VALUE OF WORK$ NEW SERVICE ❑ Overhead ❑ Underground ❑T Underground up Pole ❑Residential(Main)Service 110-100 amps 11101-1 50amps ❑151-200amps ❑ amps #of Meters ❑Commercial(Main)Service 00-100 amps ❑101-150amps ❑151-200amps ❑ amps OCT Service amps Conductor Type Size ❑Multi-Family(Main)Service 00-100 amps ❑101-150amps ❑151-200amps ❑ amps #of Unit Meters ❑Temporary Pole ❑ amps SERVICE UPGRADE ❑ amps ❑ CT Service amps NEW FEEDER(ADDITIONS,ACCESSORY STRUCTURES,ETC.) ❑100 amps ❑150amps ❑200amps ❑ amps ❑CT Service amps ADDITIONS,REMODELS,REPAIRS,BUILD-OUTS,ACCESSORY STRUCTURES,ETC. Outlets/Switches: 1-10 0-30amps 31-100amps 101-200amps Appliances: 0-30amps 31-100amps 101-200amps A/C Circuits: 0-60amps 61-100amps Heat Circuits: # circuits @ kw Number of Lighting Outlets, Including Fixtures: OTHER ELECTRICAL PROJECTS ❑Swimming Pool ❑ Sign [I Smoke Detectors_Qty ❑Transformers KVA ❑Motors hp FIRE ALARM SYSTEM (Requires 3 sets of plans) Qty volts/amps VALUE OF WORK$ REPAIRS/MISCELLANEOUS ❑Replace Burnt/Damaged Meter Can ❑Safety Inspection /anel Change ❑OH to UG ❑Other: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Q �+-� (l� ,(�/ It l Property Owners Name/k--,-)w NNm t" � mi'4 Phone Number U k \ q�6Electrical Company �� C, Office Phone ""1� Fax Co.Address: Z` 1Y 1 v A City 1� C'�94'1- State Zip�1� License Holder(Print)• y f �Q/V�� State Certification/Registration# Notarized Signature of License Holder Before me this day of 20 Signature of Notary Public r j�`�'`J:r✓J�. J CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 x1319'- PLUMBING PERMIT MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 15-PLBG-211 Job Type: PLUMBING ONLY Description: 14 fixtures Estimated Value: Issue Date: 1/27/2015 Expiration Date: 7/26/2015 PROPERTY ADDRESS: Address: 355 6TH ST RE Number: 169898-0000 PROPERTY OWNER: Name: HUNTER, MAUREEN E Address: 2747 FALCON VIEW CT GENERAL CONTRACTOR INFORMATION: Name: COGBURN AND WAKEFIELD PLBG Address: 5900 TOWNSEND BLVD APT 522 QA JOHN COGBURN Phone: - - FEES: State PLMG DBPR Surcharge $2.00 State PLMG DCA Surcharge $2.00 Plumbing Fixtures $98.00 Trade Permit Base Fee $55.00 Total Payments: $157.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. PLUMBING PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax(904) 247-5845 PERMIT# I q JOB ADDRESS: 3 �� tD ' ����3�: NEW OR REPLACEMENT INSTALLATION: Project Value$ TYPE OF FIXTURE QTY TYPE OF FIXTURE QTY Bathtub Septic Tank&Pit Clothes Washer Shower _ Dishwasher Shower Pan Drinking Fountain Slop Sink Floor Drain Three Compartment Sink Floor Sink Toilet �— Hose Bibs Urinal Kitchen Sink _ Vacuum Breakers Laundry Tray Water Connected Appliances T Lavatory _ Water Heater Other Fixtures Water Treating System RE-PIPE: TYPE OF FIXTURE QTY TYPE OF FIXTURE QTY Bathtub Septic Tank&Pit Clothes Washer Shower ( / Dishwasher Shower Pan 7 Drinking Fountain Slop Sink Floor Drain Three Compartment Sink Floor Sink Toilet Hose Bibs Urinal Kitchen Sink Vacuum Breakers Laundry Tray Water Connected Appliances Lavatory Water Heater Other Fixtures Water Treating System MISCELLANEOUS: ❑ Sewer Replacement ❑ Back Flow Preventer ❑ Grease Interceptor(Trap) gallons(Requires 3 sets of plans) ❑ Lawn Sprinkler System-Number of Heads ❑ Well ** ** SJR WD Well Completion Form. Completed form to be submitted to the Building Department for final inspection.** ❑ Other Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violatetheprovisions of any other state or local law regulation construction or the performance of construction.320 Property Owners Name B aSce `,"' �`) J , 07fzupml�zl r Phone Number '90y- Plumbing Company v� �i0r ' Office Phone 9'01-.1^2?-/t?cFax QaY-3�i-Ga3/ 8p ,q,� � City- �} State�Zip 3 22 ty Co. Address: �� License Holder(Print): o Inn �3 uAJ State Certification/Registration# `12'9l X10 Notarized Signature of License Holder Before me is ay of 20 �� i`�'YP�••r JENNIFER WALKER . �' .�� :�: , MY COMMISSION N FF 011490 ,•. EXPIRES:April 24,2017 Signature of Notary Publ c ?F ` BoMed Thru Notary Public Underwriters g CITY OF ATLANTIC BEACH sl 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 MECHANICAL GAS PIPE PERMIT MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 15-MCHG-282 Job Type: MECHANICAL GAS PIPING Description: GAS NEW HOME Estimated Value: Issue Date: 2/5/2015 Expiration Date: 8/4/2015 PROPERTY ADDRESS: Address: 355 6TH ST RE Number: 169898-0000 PROPERTY OWNER: Name: HUNTER, MAUREEN E Address: 2747 FALCON VIEW CT GENERAL CONTRACTOR INFORMATION: Name: AEI INTERNATIONAL CORP. Address: 7709 ALTON AVE QA LEWIS SPR ADLIN Phone: - - FEES: Gas Pipe Outlets $14.00 Gas Piping Units $0.00 State Mech DBPR Surcharge $2.00 State Mech DCA Surcharge $2.00 Trade Permit Base Fee $55.00 Total Payments: $73.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(``904) 247-5826 Fax (904) 247-5845 I OB ADDRESS: 35 5 (&i9 PERMIT PERMIT# PROJECT VALUE $ ARI# REQUIRED Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer RatingREQUIRED Duct Systems: Total CFM 11EPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer RatingREQUIREDDuct Systems: Total CFM FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity _ (Requires 3 sets of plans) Commercial Hoods Quantity _ (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets 1 Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets a Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: OS �1 > onth period or work is suspended or abandoned for six months I hereby certify that I have read 'crinit becomes void if work does not commence within a six m this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners NamejO.SCo �yf LlA� l�/) Phone Number L/2 2 101 CO ��(r�( � _(��f CL S Office Phone -/Jy-1��/Fax J�1 -3350 Mechanical Company dt � , Co. Address: 77jn!2 /q City 0 X State fl—Zip tea. License Holder(Print):��/n l�C� rq ci .� State Certification/Registration# 9 l � h Notarized Signature of License Ilolder 40 Po Notary Public State of Flonda Before me this�day of `ebb'(/ 20�,5L--- g4� Stephanie Renee McGuire p� My commission FF 033716 Signature of Notary Publi OF d Expires 08101/2017 FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING COS TION Florida Department of Business arid Professional Regulation Residential PerfoNTRUC method Project Name Brigman Addition 355 6th St Street 355 6th Street Builder Name Bosco Custom Homes City, State,Zip. Atlantic Beach, FL Permit Office Duval Owner: 32233- Permit Number Design Location' FL,Jacksonville Jurisdiction 261100 FNumber tion or extsungAddition9 Wall Tor multiple family ypes(1696 3 sgftInsulationSingle-family a Frame Wood FxteriorArea its, if multiple familyb. N/A R=13.0 1696.30 ft' edroomS(Bedrms In Addition) 3 3 c N/A R= ft' 5 Is this a worst case? R= ft' No 10.Ceiling Types (1310.0 sgft) Insulation 6. Conditioned floor area above grade(ft') 1310 a. Under Attic(Vented) Area b N/A R=30.0 1310.00 ft' Conditioned floor area below grade(ft') 0c. N/A R= ft' 7 Windows(254.6 s ft 11 Ducts R= ft' sqft,) Description Area a. U-Factor. Db',U=0.35 a. Sup Attic, Ret: 1st Floor,AH: 1st Floor R ft' SHGC: 254.63 ft' 6 262 SHGC=0.35 b. U-Factor. N/A ft' 12.Cooling systems SHGC: kBtu/hr Efficiency N/A ft, C. U-Factor a Central Unit 358 SEER:13.00 SHGC: d. U-Factor: N/A 13. Heating systems ft' SHGC: a. Electric Heat Pump kBtufhr Efficiency Area Weighted Average Overhang Depth: 35.8 HSPF:7.70 Area Weighted Average S1iGC: 6211 ft. 0.350 14.Hot water systems-Replacement equipment 8. Floor Types (1310.0 sgft.) Insulation Area a Natural Gas Tankless a.Slat>-On-Grade Edge Insulation Cap 1 gallons b. NIA R=0.0 1310.00 ft' R= ft' b Conservation features EF:0.590 c. N/A R= ftz None 15.Credits Pstaat F,Gla'ss":'oorrea: 0.194 Total Proposed Modified Loads: 23.1 Total Standard Reference Loads: 30.53 PASS certify that the plans and specifications covered by FReviewplans and this calculation are in compliance with the Florida Energy covered by thisO1THESr,9Codele Ener Seescates compliance �P ` ' O�PREPARED BY: `� hr Energy Code. , r " ODATE: Before construction is completed this building will be inspected for I hereby certify that this building, as designed, is in compliance compliance with Section 553.908 llr o with the Florida Energy Code. Florida Statutes � t OWNkR/AGENT: ' COD h'F'T DATEBUILDING OFFICIAL DATE: Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist i0/15Q0I 2 1;' F'M FneroyGar�ge«. USA FI�^Res20io Se<:tior,, uCF r I (or,i,i��,n� Si:(iw rr WALLS Adjacent # Ornt To Wall Iype Space Cavity Width Height - - 1 S Exterior Frame Wood R-Value Ft In F1 In Sheathing Framing Solar Below 1st Floor 13 Area R-Value Fraction Absor Grade% 2 E Exterior Frame Wood 3 3 0 8 3 0 27 4 h; p 023 08 1st Floor 13 13 0 83 p 0 3 N Exlerioi Frame-Wood 107 9 h` 0 0 23 0 8 1st Floor 13 33 0 0 -- 4 E Exterior Frame- Wood 83 0 27 4 W 0 023 p g 1st Floor 13 1.5 0 8 3 0 t 2 5 h' 0 _ 5 S Exterior Frarne-Wood 0 0 23 0 8 1st Floor 13 16 7 0 -- S Exterior Frame-Wood 0 8 3 0 138 6 ft' 0 023 p g 1st Floor 13 15 0 83 p 0 W Exterior Frame- Wood 124 5 h' 0 0.23 0.8 8 N Exterior Frame- Wood 1st Floor 13 12.7 0 83 0 105 4 h' 0 0 1st Floor 13 6 0 0.23 0.8 0 - 9 E Exterior Frame Wood 8 3 0 49 8 h' 0 0.23 0.8 1st Floor 13 7 0 8 3 0 58 1 h' 0 -10 W Exterior Frame-Wood 0 0.23 0 8 1st Floor 13 11.5 p 0 -- 1 W Exterior Frame-Wood 8.3 0 95.5 ft' 0 0.23 0.8 1st Floor 13 8 0 8.3 0 2 0 - 1 N Exterior Frame-Wood 66.4 h 0 0.23 0.8 1st Floor 13 10 0 8.3 0 � 0 - --1 E Exterior Frame-Wow 83.0 ft 0 0.23 0.8 1st Floor 13 11.5 p 0 --14 N Exterior Frame-Wood 8.3 0 95.5 ft' 0 0.23 0.8 1st Floor 13 3 0 1st Fl -15 E Exterior Frame-Wood .9 ft2 0 0.23 0.8 Floor 13 4 0 8.3 0 240 8.3 0 z 0 -16 N Exterior Frame-Wow 33.2 h 0 0.23 0.8 1st Floor 13 12 0 8.3 0 � 0 --17 E Exterior Frame-Wood 99.6 ft 0 0.23 0.8 1st Floor 13 1 g 0 -18 E Exterior Frame-Wood 0 8.3 0 149.4 ft' 0 0.23 0.8 1st Floor 13 8 0 0 --19 N *Exterior Frame-Wood 8.3 0 66.4 ft' 0 0.23 0.8 1st Floor 13 5.7 0 8.3 0 47.3 ft' 0 ---20 W Exterior Frame-Wood 0 0.23 0 8 0 1st Floor 13 8 0 8.3 0 66.4 ft' - 8 21 W Exterior Frame-Wow 0 0.23 0 1st Floor 13 20 0 -22 S Exterior Frame-Wood 0 8.3 0 166.0 ft' 0 0.23 0.8 1st Floor 13 6.166 0 8.3 0 51.2 ft' 0 0 0.23 0.8 p DOORS # Orn1 Door Type Space- --- p Storms U-Value Width Height Area 1 S --- Ft In Ft In 2 Insulated 1st Floor -------- - -- -- E Metal 28 -2-- -- -- - -- -- Insulated 1st Floor 6.7 16.8 ft' Metal 28 2 6.7 18.1 f WINDOWS Orientation shown is the entered, Pro sed / Wall orientation. _--V Ornt ID Frame Panes NFRC Overhang -- - _ U-Factor_SHGC ---- _ Area Depth Separation Int Shade 1 S 1 Vinyl Low-E Double Yes ----- --- ;,7reening - 2 E 2 Vinyl Low-E Double 35 0.35 6.7 ft' 7.5 ft 0 in 1 ft 0 in None Yes 0.35 None 3 S 5 Vinyl Low-E Double 0.35 9.0 h' 1 It 0 in 1 ft 0 in None Yes 0.35 None 4 S 5 Vinyl Low-E Double 0.35 25.0 ft' 7.5 ft 0 in 1 ft 0 in None Yes 0.35 0 35 None 5 S 6 Vinyl low-E Double 33.5 h' 7.5 h 0 in 1 h 0 in None Yes p,35 None --,� 6 W 7 Vinyl Low-E Double 0.35 25 0 h' 1 h Oil 1 h 0 in None Yes 0.35 0.35 None 7 N 14 Vinyl Low-E Double 12.0 ft' 1 ft 0 in 1 ft 0 in Yes 0.35 None None 8 N 16 Vinyl Low-E Double 0.35 10.0 ft' 20 ft 0 in 1 ft 0 in None Yes None 9 N 16 Vinyl Low-E Double 0.35 0.35 15.0 W 8 h 0 in 1 ft 0 in Yes 0.35 None None _ 10 0.35 181 h' 8h0in 1h0in --- E 17 Vinyl Low-E Double Yes 0.35 None None - 11 E 17 Vinyl Low-E Double 0.35 20.0 ft' 10 h 0 in 1 h 0 in None Yes 035 0.35 None 335E 10h0in IIt0in None None 10/1512014 34 I'M Fr�ef�ly�'a��9E°u'USA F IaRes2010 Section 40°i-1 1 (: nitrh;anl tiohwarF Paoe 3 of f; WINDOWS Orientation shown is the entered, Proposed unentation / Wall # Ornt ID Frame Panes NFRC LJ-Factor SHGC Overhang 12 N 19 Vinyl Low-E Double Yes 0 35 0 35 Area Depth Separation Int Shade Screening 6 8 h' 1 h 0 in 1 ft 0 in None None 13 N 19 Vinyl L ow-E Double Yes 035 035 18 1 h' 1 h 0 in 1 h()in None None 14 W 20 Vinyl Low-E Double Yes 0.35 0.35 10 0 ft' 1 h 0 in 1 ft O in None None __-- 15 W 21 Vinyl Low-E Double Yes 035 0.35 12.0 h' 1 h 0 in 1 ft 0 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess 0003 1030.8 56.59 10643 231 5.6885 HEATING SYSTEM # System Type Subtype - --- - _ Efficiency Capacity 1 Electric Heat Pump None p— Y - --__-_ Block Ducts HSPF:7 7 35 8 kBtu/hr 1 sys#1 COOLING SYSTEM rV � System Type Subtype Efficiency Capacity Air Flow SHR Central Unit ------ Block Ducts None SEER: 13 35.8 kB1u/hr 1074 cfm 0.75 1 sys#1 HOT WATER SYSTEM System Type SubType Location EF -— ---- -- Cap Use SetPnt - — - _ Conservation Natural Gas Tankless Exterior 059 1 gal 60 gal 120 deg NoneSOLAR HOT WATER SYSTEM C# Company Name Collector Storage __ System Model# Collector Model# Area Volume FEF None None --- / DUCTS V ----Supply---- ----Return--- # Location R-Value Area Location Area Leakage T OUT Air CFM 25 HVAC# 9 Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 262 ft' 1st Floor 65.5 ft' Default Leakage 1st Floor 9 (Default) (Default) 1 1 10i 15%201 2 34 I'M I ner GOrr erg., 9Y y USA FlaRers2UlU 40f,4 1 r"'ompfianl SofiwarF Paye 4 of F TEMPERATURES Programable 1 hermostat Y Ceiling Fans Cooling Jan F Heating X Jan Feb Mar Apr May JunJulVenting Jan Feb XMar Ma Apr )f May IXI Jun IXI Jul X Aug jXj Sep Oct Nov Apr1 May Jun Jul Aug Sep f` Oct Nov Dec Dec Ther ostat Schedule. HERS 2006 Reference g Sep IXJ Oct �X�Nov H Dec Sche ule Type 1 2 Hours 3 q 5 6 7 8 Cool/ (WD) PAM M 80 78 78 78 78 78 78 78 9 10 11 12 80 78 78 78 78 78 7g 8g 88 80 80 Cooling(WEH) AM 78 78 P M 78 78 18 78 78 78 78 78 78 78 78 78 i8 78 Healing(WD) AM 78 78 78 78 78 PM 68 66 sg B8 sg 68 68 68 68 68 68 68 Heating(WEH) AM 68 68 68 68 68 66 66 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 10/15/201 2 34 PM [nergyGaugfei, I)SA f IaRr s,:'O1(1 Srrc;lion 405 4 1 (.;onyrlrant Software Plage S of 6 FO M 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method A DRESS: 355 6th Street Atlantic Beach, FL, 32233- PERMIT # MANDATORY REQUIREMENTS SUMMARY • See individual code sections for full details. rAjr MPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC-rated as meeting ASTM E 283. Windows and doors =0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors &outdoor combustion air. Must complete envelope _ leakage report or visually verify Table 402.4.2. Thermostat 8403.1 At - _ - - - _---------- least one thermostat shall be provided for each separate heating and controls cooling system. Where forced-air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 - - ------------- uc • All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3_3 _ Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric)or shutoff(gas). Circulating system pipes insulated to= R-2 +accessible manual OFF switch. Mechanical ---- 403.5 -- -- .' ---- Homes designed to operate at positive pressure or wit mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swim ing Pools 403.9 ---__--.-- ._ - - Pool pumps and pool pump motors with a total horsepower(HP)of= 1 8 3pas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor-retardant covers or a liquid cover or other means proven to reduce heat loss except if 70%of heat from site-recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 -- � Sizing calculation performed&attached. Minimum efficiencies per I equipment Tables 503.2.3. Equipment efficiency verification required. Special I occasion cooling or heating capacity requires separate system or i I variable capacity system. Electric heat >10kW must be divided into two I or more stages. Ceiling /knee walls 405.2.1 16- R-19 space permitting. 10/15/2014 2 34 PM [ntrrgYt_inugr(' I ISA ( Section 405 4 1 Compliant Soflwafe t'ayr�f of 6 ENERGY PERFORMANCE LEVEL D (EPL) (SPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 76 The lower the EnergyPerformance Index, the more efficient the home 355 6th Street, Atlantic Beach, FL, 32233- 1. 22331. New construction or existing Addition 9 Wall Types 2 Single family or multiple family Single-familyInsulation Area a. Frame Wood,Exterior 3. Number of units, if multiple family 1 b. N/A R=13 0 1696 30 h' c N/A Rft' 4. Number of Bedrooms R== ft' . 5. Is this a worst case? 3(3) dN/A R= ft No 10.Ceiling Types Insulation Area 6. Conditioned floor area(ft') a Under Attic(Vented) 1310 b. N/A R=30.0 1310.00 ft' 1 Windows- Description R= ft2 Area c. N/A a U-Factor: Dbl,U=0.35 2 11.Ducts R ft' 25 SHGC: 4.63 ft SHGC=0.35 a.Sup:Attic,Ret: 1st Floor,AH: 1st Floor R h° b. U-Factor: N/A ft' 6 262 SHGC: c. U-Factor N/A 12.Cooling systems ft' kBtu/hr Efficiency SHGC: a.Central Unit 35 8 SEER:13.00 d. U-Factor: N/A ' ft' SHGC: 13 Heating systems Area Weighted Average Overhang Depth. 0.350 a. Electric Heat Pump kBtu/hr Efficiency Area Weighted Average SHGC: , 35.8 HSPF:7.70 350 ft. 8. Floor Types Insulation Area 14 Hot water systems-Replacement equipment a.Slab-On-Grade Edge Insulation R=0 0 1310 00 ft' b.N/A a Natural Gas c N/A R= ft' Cap: 1 gallons R= ft' b. Conservation features EF:0.59 None 15.Credits Pstal I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed(or exceeded) in this home before final inspection. Otherwise, a new EPI. Display Card will be completed based based on installed Code compliant features Builder Signature: -- Date: oc _ t7 Address of New Home: - _ City/FL Zip: COD N'E TR�S� 'Nate: This is not a Building Energy Rating If your Index is below 70, your home may qualify for energy efficient I mrtgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at 321> 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, staff contact the Florida Building Commission's support '"Label required by Section 303.1 3 of the Florida Building Code, Energy Conselvation, if not DEFAULT. FnergyGaugeC>USA FlaRes20IC Section 405 4 1 Compliant Software TABLE 402.4 2 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name __-__-- 1 Brigman Addition 355 61h St -_—__-- - --- -- Street 355 6th Street Builder Name Bosco Custom Homes City State Zip Atlantic Beach Fl 32233 Permit Office Duval Owner: Permit Number Design Location Ff Jacksonville Jurisdiction 261100 -COMPONENT CRITERIA Air barrier and thermal barrier Exterior thermal envelope insulation for framed walls is installed in CHECK --___— substantial contact and continuous alignment with building envelope air barrier Breaks or joints in the air barrier are filled or repaired. Air-permeable insulation is not used as a sealing material Air- ermeable insulation is inside of an air barrier. Ceiling/attic Air barrier in an dropped pped ceiling/soffit is substantially aligned with insulation and any gaps are sealed. Attic access (except unvented attic), knee wall door, or drop down stair is sealed. Walls Corners and headers are insulated. Junction of foundation and sill plate is sealed. Windows a4d doors Space between window/doorjambs and framing is sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including Insulation is installed to maintain permanent contact with underside above-garage and cantilevered of subfloor decking. floors) Air barrier is installed at any exposed edge of insulation. Crawl space walls Insulation is permanently attached to walls. Exposed earth in unvented crawl spaces is covered with Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, knee walls and flue shafts opening to exterior or unconditioned space are sealed. Narrow cavities Batts in narrow cavities are cut to fit, or narrow cavities are filled by sprayed/blown insulation. Garage separation Air sealing is provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures are air tight, IC rated, and sealed to drywall. Exception—fixtures in conditioned space. Plumbing and wiring Insulation is placed between outside and pipes. Batt insulation is cut to fit around wiring and plumbing, or sprayed/blown insulation extends behindi in and wiring. Shpwfr/tub on exterior wall Showers and tubs on exterior walls have insulation and an air barrier _separating them from the exterior wall Electrical/phone box on Air barrier extends behind boxes or air sealed-type boxes are installed. Commpn wall Air barrier is installed in common wall between dwelling units. HVAC register boots HVAC register boots that penetrate building envelope are sealed to ----- - - - -------_--__.-___--- subfloor or drywall Firep ace Fireplace walls include an air barrier f nergyGauge(T USA- FlaRes201C Seclion 405 4 1 Compliaru Software - - Reeves, Derek From: Reeves, Derek Sent: Monday, November 17, 2014 9:08 AM To: 'Todd Bosco' Subject: 355 6th St Permit Todd, We need a certified survey and site plan for 355 6th Street. If you have any questions, please feel free to ask. Derek W. Reeves Zoning Technician City of Atlantic Beach 800 Seminole Road Atlantic Beach, FL 32233 (904) 270-1605 dreeves(aD-coab.us i BUILDING PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Road,Atlantic Beach,FL 3' '3 Office(904)247-5826 Fax(904)247-. S Job Address: 355 6'Street Atlantic Beach FL 32233 Per, ;*Number: Legal Description 5-69 16-2S-29E 17 03101 Atlantic Beach Parcel: Floor Area of SgTt. Sq.Ft Valuation of Work$ Proposed Work heated/cooled non-heated/cnoled Class of Rork(circle one): Ncw Addition Alteration Repair Move i �Aition pool-spa window door Ilse of existing/proposed structure(s)(circle one): Commercial Resident - If an existing structure,is a fire sprinkler system installed?(Circle one): Yes `!c. N Florida Product Approval# For multiple products use product approveform Describe in detail the type of work to be performed:Addition and Remodel Property Owner Information: I Name: Kathervii Dalgleish/William Il.Brigman Address:355 61h ST City Atlantic Beach State: FL 'Lip: 32233 Phone E-Mail or Fax#(Optional) Contractor Information: Company Name:Bosco Building Contractors,Inc Qualifying Agent:T<,_'.; 3osco Address:2158 Mavnort Rd City Aiajtc Beat: State FL Lip 32233 Office Phone 904-241-0320 Job Site/Contact Number 904-241 :,•_10 Fax/f 904-241-0326_ State Certification/Registration# CBC 1250212 Architect Name&Phone# — Engineer's Name&Phone# Fee Simple Title Ilolder Name and Address Bonding Name and Address Mortgage Lender Name and Address - Application is hereby made to obtain a permit to do the work and installations as indicated I cenifi•tha, or installation has commenced poor to If issuance dtj apermit and Hurt all work will be performed to meet the standards of all laws regulating truction in this jurisdiction. This permit becomes mdl and voidif work is not commenced within six(6)months,or if construction or work is suspendeu or abandoned or appe�riod of siz(6)months a1 any time after workis commenced /understand that separate permits must be securedfor Ekealcal Work,)Ytarsblttg,atu,Wdk p�Frances, Bogws,Heaerlti Taub atdAlrCondr6o»ers,etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.IF YOU INTEND TO OBTAIN FINANCING CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. I hereby certify that l have read and examined this application and know the same to be true and correct. 'isnons of laws and ordinances governing this type of work will be cumplied with whetter spec feed herein or not. 7Zw granting of a permit does not p, .me to .fl the provisions ofan),other.jederal state l law regulating construction or the performance ofcom g a City to violate or cancel i Signature of Owner Signature of contr4l?" Print Name ' ' .... ......--_........... (J Print Name Sworn to and subscribed before me Sworn to and subscril !.,Gfare me this Day 20/x` this Z,�Day of� �yQr" 20/ Notary PublicKIK i WILLIAM L.POPE t�i Al Notary Public,State of Florida WXLIA POPE My Comm,Expires Oct.19,20-15 N UU11c,bt4 to of Florida Commission No,EE 178745 My Comm,Expires Oct Commission No. 19,Zpq.S EE 128745 Lot 24,Block 8,ATLANTIC BEACH according to the Plat thereof,as recorded in Plat Book 5,Page 69,of the Public Records of DUVAL County,Florida. Community Number:120075 Panel.0001 Suffix:D Flood Zone:X Field Work:8/25/2009 Certified To: BENJAMIN C.AND MAUREEN E.HUNTER;SUNSHINE TITLE CORPORATION;CHICAGO TITLE; Property Address: 355 6TH AVENUE ATLANTIC BEACH,FL 32233 Survey Number:152665 FNO 5 2014 LACE LmEA04AY7>7N4 umsadENT aw IL/TOFWY AC ANCOV ffA%W &pkSTNVGU"ATXW OR OAWKLRFCD0M SI.R SET RONRLYIA04P RA 964wV0E" FF FWVED FLOOR ORA ORW44C RECOWS&XW P.F. PC""POLE am BEtYC7tAtAYiK FIR FO[WOOMPff U.E. UTAtfTYEAWAFWT ra& 7GWOF84W f CEIVY 1aff Fa F01W P.C.P. FEI444NENTCaVTR0L POW W.At W47MAiEYSR ICJ CAL1AAT1'D G MEL PAN P5WA411wArFEIw%rA(0AAAeVT Fa PAGE GtTV C49LER&W W.C. *VNSSCOIR" TE.M TEWOMPYSEACHAtAW (°) PLAT CA CATCNA AV rPK FOGWPAitKEIMLfJNA0A TFL TELB4A3WFACWJ7X8 RAE PLATS" D.K DOIHOEE FCS F7311.119DGOvaNAmwv P.OA POWTOFASX~ UP.. VMflYPOLE AL DR40VIOEWEMENT FIR FOLMO"ROD P.O.C. POWTOF'C0111159AICISWENT LIQ F1aDA &W DIRIYMY L LEWTH P.aa PwoFv6mvfl cvRVAnw AE ANCIRiCaRSUMUff A CEAITA'AtAhOLMTA L.A.E [AM WACCM949BW T Pa PC1Nl oroui1rlgi'wLAws CKCKpONCREiEAKKAV11T RE X400EAHACE64 T P.RC M&T0FMWWCtVVA7LW TYLAIE DA DEED BOCK MR AtWAXE A.T. PawarpWavGY CN 0YOR0 D. DESCAPIMORDEED RAS FL7k,4WMG14t • Pl4OPERTY0100401101191ISDAR1154 EWT E4 NT MW AMA d D= ROE R00F0YE1#i+UY13'&8EA1E7►'T CONCRETE EOW. HW0FNA7ER MR AVNRADCAt R R40W(➢MAV 41-7- WOWFBVM NTS MOT7VSCALE -X--X AETALFEVX PAGE I OF 2 PAGES cFnLCRAL rte, LEGAL DESCREMON AND CERTIFICATION 1) Ur.4LaIWW7MiR70vll WBYOME" LB#6136 2I TtfELAAnSSNItFBfiS►NEA107A9STRACf41RC44YT3#tO1t1ER � D�sw4no7sr�+r avTfEPL4T. 3JIOiNWiPt�RT1AVESfJFFOCITTQItStJI2pTMB4AlAr+RpVENTSYY GET ,vartar;wArIX �r 4) M4�4tL WARE TO nEFACEOF Tf�L`WLLAW AREA�CJTTCI BEL W MAEOW r Q ��V INC, B01lNrt'A4BYLAIAE£ �* °NLSAWPMTAW�WFxSaWiV WSWW SERVING MOST FLORIDA COUNTIES n MICEOMWMWAUTDE71MOM �1 &1YATKMK491RJrP.ATR1h AREAIFEET+4h[)D t4dS�D rOAfaVDfW9 5WI CORPOWE WAY SUTE 210 8➢ EN90W WTAhCEA GRAPfGC ROMIRM&TA711CMiSIMV BFDVOXAC+08t nW FV AOW WiEST PALM SEACK FL 39407 aEARYLL46 TERUATJ MMBE7N€ENPhYSrAAftROWj9WISANCXWLOT LM PHONE (S")640-4800 BtALLCD01190MSYd4ELCGWTRULT1tELA".AMYfAcTht£A{1i44f?1EAIIFiViSO4FR FACSIMILE (881)U0OS7E SCALEDA29RAVS. STATEWIOE PHONE (800]1 7 STATEW DE FACSIMILE (800)741-0578 i A1= 90'15'04" (M) A2= 89'44'56" (M) A3= 90.15'04" (M) LOT 23 BLOCK 8 A4= 89'44'56" M 1 " ( ) FOUND /2FOUND 1/2" IRON PIPE /IRON PIPE \ \ o.o' 50.00' x 0 O II LOT 24 ^ BLOCK 8 O LOT 26 O 0 LOT 22 BLOCK 8 BLOCK 8 12.1' 12.2' 25.7 BUILDING CONCRETE ON o #355 b PROP. LINE M M 25.7' 12.2' 12.1' m � M 06 BLOCK FOUND 1/2" N FOUND 1/2" CORNER IRON PIPE o d IRON PIPE 550.00' 50.00' 0 0 6th STREET (F) o SIXTH AVENUE (P) _ 40.0' R/W SURVEY NOTES CONCRETE DRIVE CROSSING PROPERTY BOUNDARY ON SOUTHERLY SIDE OF LOT THERE ARE FENCES NEAR THE BOUNDARY OF THE PROPERTY PAGE 2 OF 2 PAGES A p, " LB#6135 N BOUNDARY SURVEY t i F t c e cl a N 11 4 No.2833 TAR(J"�T SURVEYORS CERTIFICATE W � a l HEREBY CERTIFY THAT THIS BOUNDARY SURVEY JR VEYIJW, INC. Q IS A TRUE AND CORRECT REPRESENTATION OF A SU m : SURVEY PREPARED UNDER MY DIRECTION. s STATE OF v NOT VALID WITHOUTANAUTHENTICATED ELECTRONIC SERVING ALL FLORIDA COUNTIES SON L O R I D P pQ' SIGNA TURE AND AUTHENTICATED ELECTRONIC SEAL, g s u rt v 6 ORA RAISED EMBOSSED SEAL AND SIGNATURE. 5601 CORPORATE WAY SUITE 210 WEST PALM BEACH,FL 33407 PHONE (561)640-4800 FACSIMILE (561)640-0576 (SIGNED) STATEWIDE PHONE (800)226-4807 CLYDE0.McNEAL,PROFESSIONAL SURVEYOR AND MAPPER#2883 STATEWIDE FACSIMILE (800)741-0576 Lot 24,Block 8,ATLANTIC BEACH according to the Plat thereof,as recorded in Plat Book 5,Page 69,of the Public Records of DUVAL County,Florida. Community Number:120075 Panel:0001 Suffix:D Flood Zone:X Field Work:8/25/2009 Certified To: BENJAMIN C.AND MAUREEN E.HUNTER;SUNSHINE TITLE CORPORATION;CHICAGO TITLE; Property Address: 355 6TH AVENUE ATLANTIC BEACH,FL 32233 Survey Number:152665 LEG'fAID: LALE LwAgAPTN91f4NIRaEP,iSmsw Nab' wfToFw4Y AC ARCOWWAST E7WT1WfUVATXW Olt CIFFiCW RECORM &1R BEr0?0WfiiW A GAP &R WAAMINUSINX F.F. RMWORWOR oRd Off XVIL RECORDS a" F.P. POtllC7tFULE OR Havc AKW ALP FOLIN O MPW U,E U7Vff64&9AF.VT rag TOPOFAW q C94TBNM M FaW P.C.P. PERWV43ffCONTROt POWT WA( M OFAEIM (47 CrILCMTED G ygt PAM P1}tJWVANFREfEFj9NGE'AfOAk#A I' FO AW GATv CABLEFAW w.0 N9wssCCIli164 T" 1EXA10tlIWYBEACHM41W (p) PLAT CA L:ITlaMBASAY FP.K fUWA4 WQ,0LONA0A TFL TEL54ICIMEFACAff B P.& PLArBOW ow ow PATE FCM RXAWO0AVRE7EAXMMd9VT P.aB ADATOFREOMW LLL° UTX TYPOLE AE DfiffVjGEE4SEWW FIR R7i.11,970"ROO AaC PWffOFA7NE9RCSWENT W PEZDAEASWED LY>*'' DAYM M64Y L LBKdlfl AaC AOh OF00XP f4A4DCUWATlW AE ANMphCA E49N'M' A CBV1ftAVGL6ORrA LA.E LAW 1WACCEWEt%9*NVT Pa POWT61FOtAtI AIRFA0VErLM CK GYAN*T MOA AW ALN- A64W7BW E4SSMWr PAC, ADAYTCNFRF49WCLWVATLW N ANA DEW 8009 UK A64IIYNK.ItE FT. FIOWTXI TAAYAEXY CH CH&W D. DESOWIMORDEED MW FOLMWJ� # PROP& R'WYL 1 COMOWAREA ESI4tr 6 VT NQQE ROCIFOYERAW605WENT COACRE7F EOW. EMOFNAW ALR A(AMRAM N. 940A/4 PADAW.) N=A9" M T.S. AUT TOSWE -X—X AETAL FECLE PAGE 1 OF 2 PAGES [C-EAE � LEGAL DESCRIPTION AND CERTIRICATION aWW Li01t1tP110AW8Y0r1&U LB#6136 IIAOs �i��� �� �EDBiffiFM+1 "91=UGATEIALA TTAEFi4CLA1TAENGiLCAnvAREnarTr?NUSEDTLI�EDAYSTRUCTf✓�liG'. SERVING MOST FLORIDA COUNTIES D+1ATf(w#WICAJM&MMAW VAEFTFAAR317VEpfi1i4LSA S TI1N-QVD 00 6WI CORPORATE WAY$UN7E 210 YE'WTAMIM Z 9 X9W- YTATXNCSli VFaWVFJ &MW 7W ft9AKW WEST PALM SEACK Fl SUM LLAA"MT1•R&A?�iQ1&ORS�AMJ t i8A LOTLM PM E (61)6404= C4SM�SiW�t CtJA�Tt a DfELL a4MVOP'TFESMOYFAEWSOWN FACSIMILE (bat)540-MM I3TFOW06 8TATEWDNE PHONE (8W)M407 S I'ATEV DE FACSIMILE M"741-WO I A1= 90'15'04" (M) A2= 89'44'56" (M) LOT 23 A3= 90'15'04" (M) BLOCK 8 A4= 89'44'56" (M) FOUND 1/2" FOUND 1/2" IRON PIPE\ /IRON PIPE \ 0.0' 50.00' 0.2' 0 O II LOT 24 BLOCK 8 LOT 26 S LOT 22 BLOCK 8 BLOCK 8 12.1' 12.2 25.7 BUILDING CONCRETE ON o #355 b PROP. LINE M M 25.7' 12.2' 12.1' mp6 06 o� BLOCK FOUND 1/2" FOUND 1/2" CORNER IRON PIPE o o IRON PIPE 550.00' i 50.00' 0 0 0 6th STREET (F) o SIXTH AVENUE (P) 40.0' R/W SURVEY NOTES CONCRETE DRIVE CROSSING PROPERTY BOUNDARY ON SOUTHERLY SIDE OF LOT THERE ARE FENCES NEAR THE BOUNDARY OF THE PROPERTY PAGE 2 OF 2 PAGES A o E 13 M N BOUNDARY SURVEY LB#6135 I F I C f 4y6� q l9C G f TARLTL� SURVEYORS CERTIFICATE SURVEYIN 1 No.2983 a � A W (/�� a l HEREBY CERTIFY THAT THIS BOUNDARY SURVEY ,, INC, a IS A TRUE AND CORRECT REPRESENTATION OF A a r SURVEY PREPARED UNDER MY DIRECTION. STATE OF NOT VALID WITHOUTANAUTHENTICATED ELECTRONIC SERVING ALL FLORIDA COUNTIES CN L O R I 'D P �� SIGNATUREANDAUTHENTICATEDELECTRONIC SEAL, q c S U R V E Y ORA RAISED EMBOSSED SEAL AND SIGNATURE. 5601 CORPORATE WAY SUITE 210 WEST PALM BEACH,FL 33407 PHONE (561)640-4800 FACSIMILE (561)640-0576 (SIGNED) STATEWIDE PHONE (800)226-4807 CLYOE0.McNEAL,PROFESSIONAL SURVEYOR AND MAPPER#2883 STATEWIDE FACSIMILE (800)741-0576 PROJECT Title Brigman Addition 355 6th St Building Type. User Bedroorrrs 3 Conditioned Area Address i ype Street Address Owner: 7310 Lot# #of Units: Total Stories 1 1 Worst CaseBlock/SubDivision Builder Name: Bosco Custom Homes NO PlatBook Permit Office: Rotate Angle p Duval Cross Ventilation: Street, 355 61h Street Jurisdiction: 261100 County Duval Family Type: Single-family Whole Nouse Fan. City. Stale,Zip Atlantic Beach _ New/Existing: Addition Comment FL , 32233 CLIMATE Design Location IECC Design Temp Int Design TefDegree TMY Site Zone 97.5% 2 5,�0 9 Design Daily Temp _ Winter Sumays Moisture RangeFL,Jacksonville FLJACKSONVILLEINT 2_ - 32 93 70 75 --- 49 Medium BLOCKS — Number Name ------ Area Volume 1 Blockl 1310 _ 10873 SPACES rNm _ _Name Area Volume Kitchen — Occupants Bedrooms InfillD Finished 1st Floor 1310 -- --- Cooled Heated10873 Yes q 3 --- 1 Yes YesYesFLOORS Floor TypeSpace _ __ Perimeter R-Value Areab-On-Grade Edge Insulatio -- Tile Wood Carpet 1st Floor 206 ft 01310ft' 0.3 0 0.7 ROOF Roof Gable Roof SolarType Materials SAArea Area Emitt Emitt Deck Pitch Color Absor. Tested - Tested Insul. (deg) 1 Hip Composition shingles 1465 ft- 0 ft' Medium 0.96 - No 0.9 No 0 26.6 ATTIC FYI Type Ventilation Vent Ratio(1 in) Area - - ----- RBS IRCC 1 Full attic Vented ----__--_ 300 1310 ft' N N CEILING # Ceiling Type + — Space R-Value Area 1 Under Attic(Vented) 1 S Floor - Framing Frac Truss Type 30 1310fe 017 Wood i 10/15/2014 34 Pm f ne19yr1,109WI HSA f laRe52010 Secliun 4US 4 1 (:rnnplianl�ulr, :an rage?of 6 ?� `S f CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD J ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 i Ji31>r MECHANICAL HVAC PERMIT MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 15-MECH-150 Job Type: MECHANICAL HVAC ONLY Description: DUCT WORK Estimated Value: Issue Date: 1/21/2015 Expiration Date: 7/20/2015 PROPERTY ADDRESS: Address: 355 6TH ST RE Number: 169898-0000 PROPERTY OWNER: Name: HUNTER, MAUREEN E Address: 2747 FALCON VIEW CT GENERAL CONTRACTOR INFORMATION: Name: HAMMOND AIR CONDITIONING INC Address: 3412 GALILEE RD QA DONALD E HAMMOND Phone: - - PERMIT INFORMATION: Sticker for overcurrent protection must be on A/C equipment prior to inspection. Failure to comply will result in a failed inspection and reinspect fees. No exceptions. FEES: Heat Exchanger or Coil in Ducts $10.00 State Mech DBPR Surcharge $2.00 State Mech DCA Surcharge $2.00 Trade Permit Base Fee $55.00 Total Payments: $69.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax(904) 247-5845 .TOB ADDRESS: 5`J S (.Ull� SAre-z.-.t- PERMIT# PROJECT VAL UE $ 2 6 00. ARI# REQUIRED Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells 0THE R: �'T,�e< <��� �� � �., i ,fes -*�AN, I UUL-&-L. I.o�3 a ►w�� Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name 1'Pr- ; A o N Phone Number 2-Li 037L O Mechanical Company NAArnr.Notiy Air- C1r* A6 o_--� Office Phone 314- % Fax M$-tsio�5 Co. Address: `�Ii rSF ��'� �, City j< 11P StateVL• Zip 32 zl License Holder(Print): F,.c ^� +�r, St Certification/Registration# ('BGlfi i LP44J Notarized Signature of License Holder Before me this y of 2 Signature of Notary P is CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 RESIDENTIAL ADDITION MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 14-RADD-435 Job Type: RESIDENTIAL ADDITION Description: remodel addition Estimated Value: $150,000.00 Issue Date: 12/5/2014 Expiration Date: 6/3/2015 PROPERTY ADDRESS: Address: 355 6TH ST RE Number: 169898-0000 PROPERTY OWNER: Name: HUNTER, MAUREEN E Address: 2747 FALCON VIEW CT GENERAL CONTRACTOR INFORMATION: Name: BOSCO BUILDING CONTRACTORS Address: 2158 MAYPORT RD QA TODD ALBERT BOSCO Phone: - - PERMIT INFORMATION: PUBLIC WORKS: All runoff must remain on-site. Cannot raise lot elevation without measures to retain runoff. If on-site storage is required, a post construction topographic survey documenting proper construction will be required. Full right-of-way restoration, including sod, is required. FEES: PLAN CHECK FEES $315.00 BUILDING PERMIT FEE $630.00 STATE DCA SURCHARGE $9.45 STATE DBPR SURCHARGE $9.45 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ±� ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 Total Payments: $963.90 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. Ghtty of A,,Hantic Beach APPLICATION NUMBER Building DeparLTmei'4 800 Seminole Road 6 be assigned by the Building Dipartment.) ft Atlantic Beach, Florida 32233-5445 A/ ��� q 3.15170 Phone(904)247-5826 - Fax(904)247-5845 Date routed: City web-site: http://w%Atw.(.,:)ab.us APPUCATION REVWW AND TRAC ---NG FORM Proper�y Address: De ari'arrient revoew, required Ye Uil , Apelican-' : la in�j A,7nnin Tree Administrator Project: ic W0r . ;..t� 1Public S'=Ifety Fire Review fee Dept Signature C'ONTRACTOR EMAIL ADDRESS CONTRACTOR CONTA('�- APPMATM STATUS Reviewing Departrnen't First Review: DApproved. ;Denier! (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed �Date I REE ADMIN. Second Rewic%e: ;<Approved as revised. []Denied. PUBLIC WORKS Comraenis: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by-- ] --_DWe: J4 FIRE SERVICES Third Revieird.'. DApproved as revised. oDeniee.. Comments: Reviewed by: Date: ISED 09252014 i­i-''�" City of Atlantic Beach APPLICATION NUMBER Building Departmeh 0 be assigned by the BuildingD)Qparcmen 800 Seminole Road q.3 Atlantic Beach, Florida 322:33-5445 Phone(904)247-5826 - Fax(904)247-5845 City web-site: http://www.r-,)ab.us Date routed: APPLICATION REVIEW AND TRACKM FORM Property Address: =577 EDGDartmde-nt review required Yes 0 R�]j Applicant: I'D SIR— Tree ACirninistrator Project: 0 Public Safety Fire Serv';'c­.as- Review fee $ Dept Signature ^ONTRACTOR EMAIL ADDRESS CONTRACTOR CONTACT # APPLICATION STATUS Reviewing Department First Review: ppoved. nDenier! (Circle one.) Comments: CBUILDING I- PLANNING &ZONING Reviewed by: Date: z TREE ADMIN. Second Review: []Approved as revised. [r—]]De d. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date:___ FIRE SERVICES Third Review-, ❑Approved as revised. []Denied. Comments: Reviewed by: Date: REVISED 09252014 (okly of A-flanfic Beach APPLICATION NUMBER Building Departrnran�_l "To be assigned by the Buildingq3� pa 800 Seminole Road .) A Atlantic Beach, Florida 32233-5445 �n� Phone(904)247-5826 - Fax(904)247-5845 City web-site: http://"fw,(-.,:)ab.us LL Date routed: APPLICAMN REYMW AND TRACKING FORM Properi�y Address: De i arnrj ent revie�A�!� "equired Yes No Uil AppflcawL nine a 7onin Tree Administrator Project: TIIMkDJGC.. ��� Wo, Public S ' ty Fire Sery Review fee Dept Signature 'ONTRACTOR EMAIL ADDRESS ONTRACTOR CONTAC APPMATION STATUS Reviewing Department First Review: []Approved. f=irst lkenie­ (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: Date: llh'b TREE ADMIN_ Second Revievv:_Xpproved as revised. oDenied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: >WV Date: FIRE SERVICES Third Review', E]Approved as revised. ElDenied. Reviewed bv: Date: 'ISED 09252014 9 Gotty(Of A.Hanfic Beach Building Depavtms, I APPLICATION NUMBER I - .'To be assigned by the Building D rt 800 Seminole Road jPa meqj.) Atlantic Beach, Florida 32233-5445 Phone(904)247-5826 Fax(904)2 7 5841hoV I City web-site: http://www.,--oab.us 4 Date routed: APPLICATION REYWW AND TRACKUNG FORM Property Address-' =57- De arto�_jont review, required Yer, No 01 Applican-i: I nin,-- _Z11 I T ree Ac, Project: t-K6 Jf_ strator Review fee Dept Signature CONTRACTOR EMAIL ADDRESS CONTRACTOR C0NTA(­"- . .......................................... APPIUCATMA STATUS Reviewing Department First Review: \'/Approved. ODenien' (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: Date: TREE ADMIN. Second Review: []Approved as revised. DDenied. LIC WtKS Commenis: LIC UTiLITI I Y LIC SA TY Reviewed by: Date:--- FIRE SERVICES Third Revieve pApproved as revised. oDenied. Cornrnenkg: Reviewed by: Date: ISED 09252014 NOTICE OF COMMENCEMENT (PREPARE IN DUPLICATE; FILE COPY ► Permit No. �y /�Q(� �3 S� Tax Folio No- -- State of County of DUVAL To whom it may concern: The undersigned hereby informs you that improvements will be made to certain real property, and in accordance with Section 713 of the Florida Statutes, the following Information Is stated In this NOTICE OF COMMENCEMENT. Legal description of property being improved_ S_- 61 16 -ZS JdE- 19 0.3101 A41 41-1 ffems.._ Address oYprop rty being,impA 4-i �Cj�„�c-c�. /� o,,,,. Generali description of improvemen /1�i�'nv� (..✓Low 'L�_OV� r Yl QQ r Owner .1�� �a/1 �'� ii�n 4 c' Addressnl­ S f� Owner's interest in site of the improvement Fee Simple Titleholder(if other than owner) Name Address Contractor \1 Address .21� a'� G 32 3 \ Phone No. 904-241-0320 Fax No. Surety(if any) Address Amount of bond $ Phone No. Fax No. Name and address of any person making a loan for the construction of the improvements. Name Address Phone No. Fax No. Name of person within the State of Florida. other than himself,designated by owner upon whom notices or other documents may be served: Name Address Phone No. Fax No. In addition to himself, owner designates the following person to receive a copy of the Lienor's Notir Tided in Section 713.06 (2)(b). Florida Statutes. (Fill in at Owner's option). Name Address Phone No. Fax No. Expiration date of Notice of Commencement(the expiration date is one ' different date is specified): / A1= 90'15'04" (M) A2= 89'44'56" (M) A3= 90'15'04" (M) LOT 23 A4= 89'44'56' (M) FOUND 1/2" BLOCK 8 IRON PIPE FOUND 1/2" /IRON PIPE 0.01 50.00' 0.2' / 0 LOT 24 BLOCK 8 3 'LE , LOT 26 O O BLOCK 8 p� LOT 22 ul 12.1' 12 2' N BLOCK 8 25.7 BUILDING CONCRETE ON o #355 o PROP. LINE Ld 25.7' 12.2' 12.1' m 0) Cd Ip FOUND 1/2" BLOCK IRON PIPE o FOUND 1/2" CORNER Iv 50.00' ON PIPE 550.00' 0 0 6th STREET (F) o SIXTH AVENUE (P) N suRVEY NOTA 40.0' R/W — CONCRETE DRIVE CROSSING PROPERTY BOUNDARY ON SOUTHERLY SIDE OF LOT THERE ARE FENCES NEAR THE BOUNDARY OF THE PROPERTY PAGE 2 OF 2 PAGES 4\,�a` 1 F 1 Cq Fy BOUNDARY SURVEY LB#6135 � r t No.2883 If, p SURVEYORS CERTIFICATE TAR`�� Ix I HEREBY CERTIFY THAT THIS BOUNDARY SURVEY � �� � �i ISA TRUEAND CORRECT REPRESENTATION OFA SUR VE �f STATE OF i SURVEY PREPARED UNDER MY DIRECT/ON. NO T VAL ID otigt< R I r o� d SIGNATUREANDAUTHENTICATEDELECTRONICSEAL,ELECTRONIC SERVING ALL FLORIDA COUNTIES SURVE ORA RAISED EMBOSSED SEAL AND SIGNATURE. 5601 CORPORATE WAY SUITE 210 WEST PALM BEACH,FL 33407 SIGNED) PHONE (561)640-4800 FACSIMILE (561)640-0576 CLYDE 0.MCNEAL,PROFESSIONAL SURVEYOR AND MAPPER{#2883 STATEWIDE PHONE (800)226-4807 STATEWIDE FACSIMILE (800)741-0576 Lot 24,Block 8,ATLANTIC BEACH according to the Plat thereof,as recorded in Plat Book 5,Page 69,of the Public Records of DUVAL County,Florida. Community Number:120075 Panel:0001 Suffix:D Flood Zone:X Field Work:8/25/2009 Certified To: BENJAMIN C.AND MAUREEN E.HUNTER;SUNSHINE TITLE CORPORATION;CHICAGO TITLE; Property Address: 355 6TH AVENUE ATLANTIC BEACH,FL 32233 Survey Number. 152665 i1 FILE COPY LATE L4xEu46M1amvEEASEWENT AW ROffOFWAY AC AIRCOW01tBO ER &WT1N aEVA77&W OR CM"AWLAECORDS SLR SFT0?0NROD dr9P B.R WARMRUVWKE F_F. FA#&9V R.0 X14 OR.B. OfFEw REGO RDS a" RP, POYAER PlL'E RA( CAEA4a'tA64W FLP FOtAVI MPFE U.E. VTff YE4&9W6Vr rag 7DPOFSAW q c9V7Eim R]_ FaW RCP. PERWARIfTCOWROL PORVT WA( WATPRAE7ER (63 CMCIAATM G Fist PR.AL PERW4M NTA AfONM IEVT PGt PAGE WY CMER91ER W..0 Fi97RESS CaWAR TB.Ait TEMP0VR a9 CffA6W (P) PLAT CA CATCHAW rP.K F0A0A4R7WlGi.&VA0M. TEL TaBQFKMFACNJW P.& PLATS" DA OW HaE FC-N FVLM C0N9&7FAlI0At*A9VT POB. POWTCFWGW5 LLP. UrVTYPOLE aE DR41WEFASELENT FIR FOUM6wwRCO ROC. P0NT0F00$ ifEMT Aw LMMMY L LE 10M AaC F0WT0FC01F0 WCLARWTLW AE A 0847) LAVOLE0s.TA L.A.E LW1WACLWEASEW6MT RC PO4VT0F0MVAnW 9ILLPI�LApETtTYV7X LASES CM LiAN*TEA�{444W ME A64Wn%4ACE5LS9W PAC P7AVTOFRES�SECtARVATLARE D,& OMww UK A64wX E AT PKAIVTOIFTA1NS9WY CH C'4A19W A DESOWIMORDEED FA F17bP A4W # PROPERTY0011W LOMEREDARFA EEW S4 VT AFAR AM S D= ROE: ROOF OA9&0A1GEASEMENT CAN,A*7E EQW. EWCiFW71R A(R AVNMOW R R40W(WAL) WO(7C1IYa" STS. ACT R7 SCALE I" AEML A9ka PAGE 1 OF 2 PAGES WSW N07F& LEGAL DESCRIPTION AND CERTIFICATION 1) LRmonaw7ICNrP1w➢4+>sJBYOrAs" LB#6135 $1 lfA<tAWStIGIiiVJIE ES►iiEl'7�EM0TiIGVTI FLAT 14fiMA4QIh�R TA GETAWMSNOT"MaY nsEPflAr. 3) IMS MMISA(MWWOFRVINMRX#'A47T(Jl{ OROThET7WROV61O'YT5 NOTL"70. �1r IQ1TIEFACLCAFThlIFNIAAR7AREhC1TTOLiE!lSL >nRfGYiY9TRLCT QUR� � ?'Ive d9 �MeMW AWASWOR)WESSOTh1aWWS60M SERVING MOST FLORIDA COUNTIES 7) F8WW0M0WAPAVrVMXWAW Q) gEVATIC VMi'IMVhSMWAOL-#VFa7As VaEMWSAgMD'tW MING VO fW9 4841 CORPOPATE WAY SUITE 210 B) AVSQIAsAIY R173i GytAP WRORMBTATXXitSt64WWEN OWA6M TFD rOADW WEST PALM SLACK FL 334117' aZWUMM TE MA WWaPSBETWEENP1tTl&Ca1CA♦AW40N tTSAMXWLOTLM PHONE (5")64048DO WALL a4SM 0AEAGVW,964UCONWi 7W I OrA MY OF TW SFROMOMOWW FACSIMILE (581)54GO578 SCALEDPOS7iG& STATEWIDE PHONE (800)228••48M STATEWIDE FACSIMILE (800)741-0679 WA :ijz E ILE Copy FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE Florida Department of Business and Professional Regulation Residential Performance Method Project Name Brigman A ---7 ddition 355 6th St Street 355 6th Street Budder Name Bosco Custom Homes City, State,Zip. Atlantic Beach. FL , 32233- Permit Office Duval Owner. Permit Number Design Location FL,Jacksonville Jurisdiction 261100 1 New construction or existing Addition ) 2 Single family or multiple family 9 Wall Types(1696 3 sgft Insulation Area Single-family a Frame Wood, Exterior 3 Number of units, if multiple family 1 b N/A R=13.0 1696.30 ft' 4 Number of Bedrooms(Bedrms In Addition) 3(3) c N/A R= ft' d. N/A R= ft' 5 Is this a worst case? R= ft' No 10.Ceiling Types (1310.0 sgft) Insulation 6. Conditioned floor area above grade(ft') 1310 a. Under Attic(Vented) Area b N/A R=30.0 1310.00 ft2 Conditioned floor area below grade(ft') pR= ft2 c. N/A 7. Windows(254.6 s ft.) Description 11 Ducts R= ft' q Area a. U-Factor. Dbl,U=0.35 a. Sup:Attic,Ret: 1st Floor,AH: 1st Floor R ft' SHGC: 254.63 ft' 6 262 SHGC=0.35 b. U-Factor. N/A f(' 12.Cooling systems SHGC: kBtu/hr Efficiency N/A ft' C U-Factor: a Central Unit 358 SEER:13.00 SHGC: d. U-Factor: N/A13 Heating systems SHGC: a. Electric Heat Pump ft' kBtu/hr Efficiency Area Weighted Average Overhang Depth: 35.8 HSPF:7.70 Area Weighted Average SHGC: 6 211 ft. 0.350 14. Hot water systems-Replacement equipment 6. Floor Types (1310.0 sgft.) Insulation Area a Natural Gas Tankless a.Slab-On-Grade Edge InsulationCap: 1 gallons b. N/A R=0.0 1310.00 ft' R_ b Conservation features EF:0.590 c.N/A re one R= ft' 15.Credits Pstet Glass/Floor Area: 0.194 Total Proposed Modified Loads: 23.06 /� Total Standard Reference Loads: 30 53 PASS I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Ener O,�YIE STgT�o Code. 9y specifications covered by this �e Ener Services calculation indicates compliance �xvt I PREPARED BY: hr _ with the Florida Energy Code. u° r ';. O DATE: Before construction is Completed W this building will be inspected for I hereby certify that this building,as designed, is in compliance compliance with Section 553.908 with the Florida Ener Florida Statutes t Energy Code. tiCOD H�T��9 OWNER/AGENT: DATE: BUIL-DING OFFICIAL' /71 11 DATE: /foia- jay Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist �0/11Sr7014 "1 2-4 ",%rj E nergvGar.GeO USA FlaRes2010 Section 405 4 1 PROJECT Title: Brigman Addition 355 61h St Building Type. User Bedroorrrs 3 Conditioned Area Address 1 ype Street Address Owner: 1310 #of Units: 1 Total Stories 1 Lot# Builder Name: Worst Case Block/SubDivision Bosco Custom Homes No PlatBook Permit Office: Duval Rotate Angle 0 Cross Ventilation: Street. 355 6th Street Jurisdiction: 261100 Family Type: Single-family Whole House Fan. County Duval New/Existing: Addition City. State,Zip Atlantic Beach _ Comment: Ft , 32233 CLIMATE V Design Location IECC Design Temp Int Design Temp Heating TMY Site Zone 97.5% 2 5"�a g 9y Design Daily Temp __ Winter Summer Degree Das Moisture Range FL,Jacksonville FL JACKSONVILLE INT ---- 2 32 -93 - _- --- 70 75 1281 49 Medium BLOCKS Number Name -------- - ___ Area Volume 1 Blockl _-- -_ - - - 1310 10873 SPACES Number -- Name,--= Area Volume_ _ Kitchen Occupants -----------_ Bedrooms Infil ID Finished 1 1st Floor Cooled Heated 1310 _. 10873 Yes q - 3 1 Yes Yes Yes FLOORS # Floor Type Space _ Perimeter -- -- - 1st Floor 206 fl 0 R-Value Slab-On-Grade Edge Insulatio Area - Tile Wood Carpet 1 Sl1310 ft' -- - - ---- 0.3 0 0.7 / ROOF # Type Materials Roof Gable Roof Solar Area AreSEmitt Emitt --- a Color----- _ -- -- __ ___-- Absor. Tess Deck Pitch Tested Tested Insul. (deg) 1 Hip Composition shingles 1465 ft' 0 h' .- Medium 0.96 No 0.9 No 0 26.6 ATTIC # Type --- Ventilation Vent Ratio(1 in) Area RBS IRCC ------ 1 Full attic Vented - ---_.____ _ 300 1310 ft' N N CEILING # Ceiling Type -- Space R-Value Area --- 1 Under Attic(Vented) Framing Frac Truss Type IslFloor 30 1310f(2 0 11 Wood 10/15/2014 2 34 PM f ne 0r1,104P.: USA F IaRes"1010 Section 405 4 1 Caniptianl Sofr.,;{rr, I'aye,1 of 6 WALLS Adjacen( # Ornt To Wall typeCavity Width Space R-Value Fifciynt Sheathing Framing Solar 1 S Exterior Frame Wood Ft In Beic� 1st Floor 13 Area R-Value Fraclion Absor Grade',, --- 2 E Exterior Frame Wood 3 3 0 83 0 27 q ft 1st Floor 0 107 9 fi� 0 023 08 13 13 0 8 3 3 N Exterior Frame- Wood 0 023 p g v Ist Floor 13 3 3 0 8 3 0 0 -- 4 E Exterior Frame- Wood 27 4 ft` 0 0 23 0 8 1st Floor 13 1 5 0 8 3 0 12 5 h' 0 ---- 5 S Exterior Frame-Wood 0 0 23 0 8 1st Floor 13 16 7 0 83 0 138 6 ft; 0 -- 6 S Exterior Frame Wood 0 0 23 0 8 1st Floor 13 15 0 8 3 0 124 5 4, --- 7 W Exterior Frame- Wood 0 0 23 0 8 c 1st Floor 13 12.7 0 83 0 105 4 h' 0 -- 8 N Exterior Frame - Wood 0 0 23 0.8 1st Floor 13 6 0 83 p0 - 9 E Exterior Frame- Wood 49 8 h' p 1 st Floor 13 7 0.23 0.8 p 1st Floor __10 W Exterior Frame Wood 1 0 8 3 0 58.1 ft' 0 0.23 p 1st Floor 13 11.5 p g 1St Floor 13 8 0 8.3 0 --11 W Exterior Frame-Wood 8.3 0 95.5 ft' 0 0.23 0.8 0 -_- 12 N Exterior Frame Wood 66.4 ft� 0 0.23 p_g p ____13 E Exterior Frame-Wood 13 10 0 8.3 0 83.0 ft2 0 0.23 0.8 0 1st Floor 13 11 5 0 8.3 0 z 0 --14 N Exterior Frame-Wood 95.5 ft0 0.23 0.8 tst Floor 13 3 0 8.3 p , 0 ___15 E Exterior Frame-Wood 24 9 ft 0 0.23 0.8 1st Floor 13 4 0 8.3 p z 0 16 N Exterior Frame-Wood 33.2 ft 0 0.23 0.8 1st Floor 13 12 0 8.3 0 2 0 -17 E Exterior Frame-Wood 99.6 h 0 0.23 0.8 1st Floor 13 18 0 8 3 0 149 4 ft' 0 -18 E Exterior Frame-Wood 0 0.23 0.8 1st Floor 13 8 0 0 -19 N Exterior Frame-Wood 8.3 0 66.4 h' 0 0.23 0.8 1st Floor 13 5.7 0 83 0 47.3 ft' 0 ----20 W Exterior Frame-Wood 0 0.23 0.8 0 1st Floor 13 8 0 8.3 0 66.4 ft' -21 W Exterior Frame-Wood 0 0.23 0.8 1st Floor 13 20 0 _-_- 22 S Exterior Frame-Wood 0 8.3 0 166.0 ft' 0 0.23 0.8 1st Floor 13 6.166 0 83 0 51.2 ft' 0 0 0.23 0.8 DOORS # Ornt Door Type Space p Storms U-Value Width 1 --- Height Area 1st Floor Me -- Insulated Metal- Ft In Ft In 2 t= Insulated .28 25 1st Floor 67 Metal 28 2 i 6.7 18.1 ft' WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Ornt ID Frame s PaneOverhang --- - .- __ _ _NFRC U-Factor SHGC 1 S 1 y - Area Depth Separation Int Shade_ Screening Vin I Low-E Double Yes035 __-- --- ------_ 2 E 2 Vinyl Low-E Double 0 35 0.35 6.7 h' 7.5 fl 0 in 1 ft 0 in None Yes None 3 S 5 Vinyl low-E Double 0.35 0.35 9.0 ft' 1 ft 0 in 1 ft 0 in None Yes None 0.35 0.35 25.Oft' 75h0in 1ft0in -- 4 S 5 Vinyl Low-E Double None None Yes 0.35 035 33.5 h' 7.5h0in 1ft0in 5 S 6 Vinyl low-E Double None None Yes 0.35 0.35 25 0 h' 1ft 0 in 1 ft 0 in 6 W 7 Vinyl Low-E Double Yes None None 0.35 0.35 120E 1h0in 1h0in - 7 N 14 Vinyl Low-E Double None None Yes 0.35 0.35 10.0 h' 20 h 0 in 1 ft 0 in 8 N 16 Vinyl Low-E Double None None Yes 035 0.35 15.0 ft' -- 9 N 16 Vinyl low-E Double 8 h 0 in 1 h 0 in None Yes 0.35 None 10 E 17 Vinyl Low-E Double 0.35 18 1 ft' 8 ft 0 in 1 ft 0 in Yes None None E 17 Vinyl Low E Double Yes 0.35 0.35 20 0 h' 10 h 0 in 1 ft 0 in None None 035 035 335 f1' 10h0ir, 1h 0 i None None i Oi i Si201 a 7 3,1 Iv I ner<ryGaugc��`;1SA f IaRes20r0 section 40`, 1 1 (., nit,lr,tnl Sr,1rw,:,p- I'age 3 of fsr WINDOWS Orientation shown is the entered, Proposed onenlation V # Ornt ID Frame Panes NFRC U-Factor SHGC Overhang Area Depth Separation Int Shade Screening 12 N 19 Vinyl Low-E Double Yes 035 035 68h' 1 h0in 1 ft0in 13 N 19 Vinyl low-E Double None None Yes 0 35 035 18 1 h' t h 0 in 1 ft 0 in 14 W 20 Vinyl Low-E Double Yes None None 15 W 21 Vinyl Low-E Double 0.35 0.35 10 0 h' 1 h 0 in 1 h 0 in None Yes 0 35 None 0 35 12.0 ft' t h 0 in 1 h 0 in None None INFILTRATION # Scope Method SLA CFM 50 _ ELA EgLA ACH ACH 50 1 Wholehouse Best Guess -- 0003 1030.8 56.59 10643 231 5.6885 HEATING SYSTEM # System Type Subtype 1 Electric Heat Pump None Efficiency Capacity Block_ Ducts HSPF: 7 7 35.8 kBtu/hr 1 sys#1 COOLING SYSTEM VE ype Subtype_ -- Efficiency Capacity Air Flow it None ------ SHR Block Ducts SEER: 13 35.8 kBtu/hr 1074 cfm 0.75 1 sys#1 HOT WATER SYSTEM Type SubType Location _ EF Cap Use as Tankless SetPntConservation Exterior 0.59 -- -1gal 60 gal 120 deg NoneSOLAR HOT WATER SYSTEM Company Name Collector Storage System Model# Collector Model# Area --------- . - -- Volume FEF ---- one None - _ ___-.-- --__ - —------------------- ft' DUCTS ----Supply--- ----Return---- Air CFM 25 CFM25 V # Location R-Value Area Location Area HVAC# __ Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 262 ft' —1st Floor 65.5 ft' Default Leakage 1st Floor - (Default) (Default) 1 1 10/15%2014 2 34 f'M f nergyGaugerk,USA f IsReS2010 St•clirnr 405 4 1 Complianl Software Paye 4 0l 6 TEMPERATURES Programable thermostat Y Ceiling Fans Cooling Jan Heatin Feb Mar Venting Jan Feb FebMar Apr May jXj Jun IXI Jul iXI AAu ug �Xj Sep )Oct Nov Dec X Mar lxJ p ]OctY Jun Jul fX] Nov f Dec Thermostat Schedule. HERS 2006 Reference Aug Sep Oct Nov Dec Schedule Type 1 Hours 2 3 4 5 6 7 8 Cooling(WD) g 10 11 12 AM 78 78 78 78 78 PM 80 80 78 8 78 78 Cooling(WEH) 78 7 78 78 78 88 88 88 88 PM 78 78 78 78 78 78 Heating(WD) 78 78 78 78 78 78 78 78 78 76 78 78 AM 66 66 78 78 78 78 PM 68 68 66 66 66 68 68 68 68 68 68 6 68 68 68 68 66 68 68 Heating(WEH) AM 66 68 66 66 66 66 PM 68 66 68 68 68 68 6868 68 68 68 68 68 6868 68 668 68 6 66 10/15/2014 2 34 PM FnergyGauge(v I)SA FIaRr sl01O Section 405 4 I Com1>hanl Software Page 5 of 6 FORM 405 10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: 355 6th Street Atlantic Beach, FL, 32233- PERMIT # MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REOUIREMENT(S) Air leakage402 q CHECK To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC-rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat 8 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced-air furnace is primary system, Programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2All d - -- - —-----_ _---- ucts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric)or shutoff(gas). Circulating system pipes insulated to= R-2 -- + accessible manual OFF switch. Mechanical 403.5 ------ ---- --Homes designed designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 4039 & Spas Pool pumps and pool pump motors with a total horsepower(HP)of= 1 HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor-retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site-recovered energy. off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. i Cooling/heating 403.6 - { Sizing calculation performed& attached. Minimum efficiencies per i equipment i Tables 503 2.3. Equipment efficiency verification required. Special t i occasion cooling or heating capacity requires separate system or I variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2 1 R-19 space permitting. 1011512014 7 34 f'M F nergy( , yr I LCA (I;i(�Fi5y010 Section 4051 1 Compliant So(Iwa,, !'aua G u!6 ENERGY PERFORMANCE LEVEL (EPL) ( L) DISPLAY CARD FS1 IMA1 ED ENERGY PERFORMANCE INDEX* = 76 The lower the EnergyPerformance Index, the more efficient the home 355 6th Street, Atlantic Beach, FL, 32233- 1. New construction or existing Addition 2 Single family or multiple family 9. Wall Types Insulation Area Single-family a.Frame-Wood,Exterior R=13 0 1696 30 ft' 3. Number of units, if multiple family 1 b. N/A R_ h' 4. Number of Bedrooms c N/A R= ft' 3(3) d. N/A R= h' 5. Is this a worst case? No 10.Ceiling Types a. Under Attic(Vented) Insulation Area 6. Conditioned floor area(ft') 1310 ( ) R=30.0 1310.00 h' 7 Windows— - b. N/A Descriptionc. N/A R ft' a. U-Factor: Area R= ft' Dbl,U=0.35 254.63 ft' 11, Ducts SHGC: N/A ft'SHGC=0.35 a.Sup_Attic,Ret: 1st Floor,AH: 1st Floor R h' b. U-Factor: 6 262 SHGC: c. U-Factor N/A12.Cooling systems ft' kBlu/hr Efficiency SHGC: a. Central Unit 35 8 SEER:13.00 d. U-Factor: N/A h' SHGC: 13. Heating systems Area Weighted Average Overhang Depth: 6,211 fta. Electric Heat Pump kBtu/hr Efficiency Area Weighted Average SHGC: 35.8 HSPF:7.70 0.350 8. Floor Types Insulation Area 14.Hot water systems-Replacement equipment a.Slab-On-Grade Edge Insulation R=0 0 131000 h' a. Natural Gas Cap: 1 gallons b.N/A R= ft' c. N/A EF:0.59 R= ft' b Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed(or exceeded) OF qTF in this home before final inspection. Otherwise, a new EPL Display Card will be completed SHE ST v _ Q based on installed Code compliant features. Builder Signature: Date: 94 �- Address of New Home: -- City/FL Zip: wE "Note: This is not a Building Energy Rating If your Index is below 70, your home may qualify for energy efficient mortgage(EEM)incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web Site at energygauge com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff "Label required by Section 303.1 3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge@ USA FlaRes201C Section 405 4 1 Compliant Software TABLE 402.4.2 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA FoesignLocation Brigman Addition 355 6th St `—'---- 355 61h Street Builder Name Bosco Custom Homes Atlantic Beach Ft 32233 Permit Office Duval Permit Number Ft Jacksonville Jurisdiction: 261100 COMPONENT CRITERIA �- ------- Air barrier and thermal barrier Exterior thermal envelope insulation for framed walls is installed in CHECK substantial contact and continuous alignment with building envelope air barrier. Breaks or joints in the air barrier are filled or repaired. Air-permeable insulation is not used as a sealing material. Air- ermeable insulation is inside of an air barrier. Ceiling/attic Air barrier in an dropped pped ceiling/soffit is substantially aligned with insulation and any gaps are sealed. Attic access (except unvented attic), knee wall door, or drop down stair is sealed. Walls Corners and headers are insulated. Junction of foundation and sill plate is sealed. Windows acid doors Space between window/door jambs and framing is sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including Insulation is installed to maintain permanent contact with underside above-garage and cantilevered of subfloor decking. floors) Air barrier is installed at any exposed edge of insulation. Crawl space walls Insulation is permanently attached to walls. Exposed earth in unvented crawl spaces is covered with Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, knee walls and flue shafts opening to exterior or unconditioned space are sealed. Narrow cavities Batts in narrow cavities are cut to fit, or narrow cavities are filled by sprayed/blown insulation. Garage separation Air sealing is provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures are air tight, IC rated, and sealed to drywall. Exception—fixtures in conditioned space. Plumbing and wiring Insulation is placed between outside and pipes. Batt insulation is cut to fit around wiring and plumbing, or sprayed/blown insulation extends behindi in and wirin . Shpwer/tub on exterior wall Showers and tubs on exterior walls have insulation and an air barrier se2arating them from the exterior wall. Electrical/phone box on Air barrier extends behind boxes or air sealed-type boxes are installed. Common wall — — Air barrier is installed in common wall between dwelling units. HVAC register boots HVAC register boots that penetrate building envelope are sealed to ------ subfloor or drywall. Fireplace _ _ Fire lace walls include an air barrier. F nefgyGaugee!�USA- FlaRes2o1,^,Section 405 4 1 Corrrplianl SoftwarF W FILE COPY i yF Brigman Addition 355 6th St Atlantic Beach HVAC Load Calculations for Bosco Custom Homes CFBJ jilSo RHVACRu61D8rt`nAL HVAC LOADS i Prepared By: Jason McDuffie Home Energy Services 2060 Davis Rd. Jacksonville, FL 32218 904 757-3569 Wednesday, October 15,2014 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Elite Rhvac-Residential&Light Commercial HVAC Loads Brigman Addison b5 6th Development,Atlantic Beach Home Ener Services Jacksonville. FL 32218 _ Page 2 i` Project Report_ --- — ---------- General Project Information Project Title: Brigman Addition 355 6th St Atlantic Beach Designed By: Alexa Laughren Project Date: Wednesday, October 15, 2014 Project Comment: This equipment can be replaced in name or by equal or greater SEER or HSFP as stated on the FL. Energy Code Client Name: Bosco Custom Homes Company Name: Home Energy Services Company Representative: Jason McDuffie Company Address: 2060 Davis Rd. Company City: Jacksonville, FL 32218 Company Phone: 904 757-3569 Company E-Mail Address: ecalcs@hesjax.com Company Website: www.hesjax.com Company Comment: Design Data Reference City: Jacksonville, Florida Building Orientation: Front door faces South Daily Temperature Range: Medium Latitude: 30 Degrees Elevation: 26 ft. Altitude Factor: 0.999 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 32 29.92 n/a n/a 70 n/a Summer: 95 77 45% 50% 75 46 Plie&Figures Total Building Supply CFM: 1,245 CFM Per Square ft.: 0.951 Square ft. of Room Area: 1,310 Square ft. Per Ton: 518 Volume(ft3)of Cond. Space: 10,873 uiidi Loads Total Heating Required Including Ventilation Air: 29,077 Btuh 29.077 MBW Total Sensible Gain: 27,371 Btuh 90 % Total Latent Gain: 2,980 Btuh 10 % Total Cooling Required Including Ventilation Air: 30,351 Btuh 2.53 Tons(Based On Sensible + Latent) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. j All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C \ \Brigman Addition 355 6th St.rh9 Wednesday, October 15; 2014, 2:01 PM ---------- ------- --- Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Home Energy Services Brigman Addition 355 6th St Atlantic Beach Jacksonville,FL 32218 Page 3 Miscellaneous Report Input Data St Floor -- - -- Outdoor b .Wet Bulb eLHumr -Re1.Humr D InBoob - Differencns- e � -- - --- Winter32 29 92 80% n/a 70 n"a Summer 95 77 45% 50% 75 46 4? ,Duct Sizing Inputs Main Trunk Runouts Calculate: Yes Yes Use Schedule. Yes Yes Roughness Factor: 0.01000 0.01000 Pressure Drop: 0.1000 in.wg./100 ft 0.1000 in.wg./100 ft Minimum Velocity: 550 ft/min 450 ft./min Maximum Velocity: 600 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Winter Summer Infiltration Specified: 0.250 AC/hr 0.250 AC/hr 45 CFM 45 CFM Infiltration Actual: 0.250 AC/hr 0.250 AC/hr Above Grade Volume: X 10.874 Cu.ft. X 10,874 Cu.ft. 2,719 Cu.ft./hr 2,719 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 45 CFM 45 CFM Total Building Ventilation: 0 CFM 0 CFM ---System 1--- Infiltration&Ventilation Sensible Gain Multiplier: 21.98 = (1.10 X 0.999 X 20.00 Summer Temp. Difference) Infiltration &Ventilation Latent Gain Multiplier: 31.54 = (0.68 X 0.999 X 46.43 Grains Difference) Infiltration &Ventilation Sensible Loss Multiplier: 41.76 = (1.10 X 0.999 X 38.00 Winter Temp. Difference) Winter Infiltration Specified: 0.250 AC/hr(45 CFM) Summer Infiltration Specified: 0.250 AC/hr(45 CFM) Dud Load Factor Scenarios for System 1 Attic Duct L .tet Surface T-- - From [No. Type Description - - Location Ceiling - Leakage Insulation _ _ Area MDD 1 Supply Main Attic 16B 009 6 354 No 1 Return Main Attic 16B 015 6 131 No i C:\ \Brigman Addition 355 6th St rh9 Wednesday, October 15, 2014, 201 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Home Energy Services Brigman Addition 355 6th St Atlantic Beach Jacksonville,FL 32218 Page 4-- i Load Load Preview Report Scope Ton lion Area Gain Galet ft2 San an Gaint San Sys Sys Loss Mg G9 Ac $� CFM CFM CFM Building 2.53 518 1,310 27,371 2,980 30,351 29,077 588 1,245 1,245 System 1 2.53 518 1,310 27,371 2,980 3Q 351 29,077 588 1,245 1245 20 Duct Latent 751 751 Zone 1 1,310 27,371 2,229 29,600 29,077 588 1.245 1,245 201 1-Foyer 52 1,524 137 1,661 2,739 55 69 69 1 b' 2-BreakfasVKdchen 203 4,075 327 4,402 2,985 60 185 185 2-61 i 3 Living Room 195 5,354 836 6,190 4287 87 244 244 3-6i 4-Bath2 49 1,022 49 1p71 1,015 21 46 46 1-4 5-Bedroom 3 121 3,042 80 3,122 2,012 41 138 138 2-6 6-Laundry 28 59 0 59 39 1 3 3 1-4 7-Master Bath 84 424 56 480 973 20 19 19 1-4 8-Bedroom 2 105 2,620 150 2,770 3A53 62 119 119 2-4 9-Hal l 120 962 49 1,011 1,442 29 44 44 1-4 10-Master Bedroom 216 3,742 210 3952 4,649 94 170 1701 2-6 11-Office 48 3A35 152 3,187 2A48 58 138 138 2-6 12-M Closet 90 1,513 183 1,696 3,034 61 69 69 1-6 C:A \Brigman Addition 355 6th St rh9 Wednesday. C)ctohei 15, 2014, 2:01 PM Home Energy Services -9 - - Brigman Addition 355 6th St Atlantic B eaech Rhvac-Residential&Li ht Commercial HVAC Loads Elite Software Develo ment,Inc. Jacksonville,FL 32218 Duct Size Preview --- -- - - - --- _ -_ _ _ --- Roorn or T -^ '_- MMaximum Rough Design SP Duct Duct � Act. Duct Duct Velocity Velocity Factor L/100 Loss Velocity Length Flow Source Name Flow Flow Size System 1 Supply Runouts Zone 1 1-Foyer Built-In 450 750 0.01 0.1 508.4 55 69 1-5 2-Breakfast/Kitchen Built-In 450 750 0.01 0.1 472.2 60 185 2-5 3-Living Room Built-In 450 750 0.01 0.1 595.5 87_ 244 3-5 4-Bath 2 Built-In 450 750 0.01 0.1 532.8 21 -' 46 1-4 5-Bedroom 3 Built-In 450 750 0.01 0.1 507.6 41 i 138 2-5 6-Laundry Built-In 450 750 0.01 0.1 30.6 1 _ 3 1-4 7-Master Bath Built-In 450 750 0.01 0.1 220.9 20_ 19 1-4 8-Bedroom 2 Built-In 450 750 0.01 0.1 683 62_I 119 2-4 9-Hall Built-In 450 750 0.01 0.1 501.6 29- 44 1-4 10-Master Bedroom Built-In 450 750 0.01 0.1 624.3 94 170 2-5 11-Office Built-In 450 750 0.01 0.1 506.4 58 MMpaj 138 2-5 12-M.Closet Built-In 450 750 0.01 0.1 504.8 61jnW­ 69 1-5 Other Ducts in System 1 Supply Main Trunk Built-In 550 600 0.01 0.1 570.8 588 1245 20 -__- _- ----- Summary System 1 Heating Flow: 588 Cooling Flow. 1245 I C \ \Brigrnan Addition 355 6th SI rh9 Wednesday, October 15; 2014, 2 01 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Home Energy Services Brigman Addition 355 6th St Atlantic Beach Jacksonville, FL 32218 pie g Total Building Summate Loads ornponenDCes�tiont Quan Loss Gain --Gain__ Gain Area Sen Sentall 4A-6-o: Glazing-Double pane low-e (e = 0.20 or less), 151 4 1,807 0 3,113 3,113 high performance, operable window, e=0.05 on surface 2, any frame, u-value 0.33, SHGC 0.33 1OD-f: Glazing-French door, double pane low-e glass (e = 103.2 1,646 0 1,552 1,552 0.10), insulated fiberglass frame, u-value 0.42, SHGC 0.32 1D-cv-o: Glazing-Double pane, operable window, clear, 63.2 1,367 0 3,547 3,547 vinyl frame, u-value 0.57, SHGC 0.56 11J: Door-Metal- Fiberglass Core 34.8 794 0 648 648 i 12C-Osw: Wall-Frame, R-13 insulation in 2 x 4 stud 1343.6 4,648 0 3,238 3,238 cavity, no board insulation, siding finish, wood studs 16B-30: Roof/Ceiling-Under Attic with Insulation on Attic 1310 1,592 0 2,304 2,304 Floor(also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-30 insulation 22A-ph: Floor-Slab on grade, No edge insulation, no 206 10,630 0 0 0 insulation below floor, any floor cover, passive, heavy moist soil Subtotals for structure: 22,574 0 14,402 14,402 People: 4 800 920 1,720 Equipment: 0 6,100 6,100 Lighting: 0 0 0 Ductwork: 4,611 751 4,952 5,703 Infiltration: Winter CFM: 45, Summer CFM: 45 1,892 1,429 997 2,426 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 Total Building Load Totals: 29,077 2,980 27,371 30,351 Piwk Figures Total Building Supply CFM: 1,245 CFM Per Square ft.: 0.951 Square ft. of Room Area: 1,310 Square ft. Per Ton: 518 Volume(ft')of Cond. Space: 10,873 [Buildingload Total Heating Required Including Ventilation Air: 29,077 Btuh 29.077 MBH Total Sensible Gain: 27,371 Btuh 90 % Total Latent Gain: 2,980 Btuh 10 % Total Cooling Required Including Ventilation Air: 30,351 Btuh 2.53 Tons(Based On Sensible + Latent) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at yqur design conditions. I C:\ .. \Brigman Addition 355 6th St rhq Wednesday, October 1.5, 2014, 2 01 PM g Bri man Addition 355 6th St Atlantic Beach Rhvac-Residential&Li ht Commercial HVAC Loads Elite Software Development,Inc. 1 Home Energy Services � g Pa e� . Jacksonville,FL 32218 _ -- — -- -- _--_--_ -- __-- -_ _ g Building Pie Chart Infiltration 7% Ductwork 16% Floor 37% Building Door 3% Loss 29,077 Btuh Glass 17% Roof 5% Wall 16% Roof 8% Infiltration 8% Wall 11% Ductwork 19% Building Gain 30,351 Btuh Glass 27% Equipment 20% Door 2% People 6% - -- J C\ Trigrnan Addition 355 6th 5t nc� WF�dnesday, (kaob�r 15, 2014: 2'01 PM Elife are Development, Inc. j Home Energy Services Light Commercial HVAC Loads Brigman Addition 55 6th St Atlantic Beach I,Jacksonville, FL 32218 Page 8 System 1 Room Load Summary Htg Min Run Run Clg Cig Min Ad Room Area Sens Htg Duct Duct Sens Lat Cig Sys No Name SF Btuh CFM Size Vel _Btuh Btuh CFM CFM --Zone 1-- 1 Foyer 52 2,739 55 1-5 508 1,524 137 69 69 2 Breakfast/Kitchen 203 2,985 60 2-6 472 4,075 327 185 185 3 Living Room 195 4,287 87 3-5 595 5,354 836 244 244 4 Bath 2 49 1,015 21 1-4 533 1,022 49 46 46 5 Bedroom 3 121 2,012 41 2-5 508 3,042 80 138 138 6 Laundry 28 39 1 1-4 31 59 0 3 3 7 Master Bath 84 973 20 1-4 221 424 56 19 19 8 Bedroom 2 105 3,053 62 2-4 683 2,620 150 119 119 9 Hall 120 1,442 29 1-4 502 962 49 44 44 10 Master Bedroom 216 4,649 94 2-5 624 3,742 210 170 170 11 Office 48 2,848 58 2-5 506 3,035 152 138 138 12 M. Closet 90 3,034 61 1-5 505 1,513 183 69 69 Duct Latent 751 System 1 total 1,310 29,077 588 27,371 2,980 1,245 1,245 System 1 Main Trunk Size: 20 in. Velocity: 571 ft./min Loss per 100 ft.: 0.041 in.wg N06ling System Summary - - -- - ---- -__ -_ ---- _ _ -ooln - - S-e-_ni-ble/La_ent --- _ _Sensible- - ---Latent - - - Total: "- Tons Split Btuh Btuh Btuh Net Required: 2.53 90% / 10% 27,371 2,980 30,351 Actual: 2.98 75% /25% 26,850 8,950 35,800 Equipment Data Heating System Cooling System Type: Air Source Heat Pump Air Source Heat Pump Model: 4TW R3036C1 4TW R3036C1 Indoor Model: 4TEC3F42C1 Brand: TRANE TRANE Description: Air Source Heat Pump Air Sou,;e Heat Pump Efficiency: 7.7 HSPF 13 SEER Sound: 0 0 Capacity: 35,200 Btuh 35,800 Btuh Sensible Capacity: n/a 26,850 Btuh Latent Capacity: n/a 8,950 Btuh AHRI Reference No.: n/a 7117071 C,�\ 1Brigrnan Addition 3596th St rhU Wednesday, Octoher 15, 2014, 2 01 PM 77 f c r�j bC.2d c u 4J C.O 4- v c U cccc - W / cc o a c --- O � 4- o c�. C7, ° L o on '- D -5 > o O c ° a " - co u =3 i 1� O � LL co C C ccz �. 4 •1 rl G G i v , C �♦ J Y v - .. 7. i A '. /� v " � `• � til u N r- u cv N1 9 ar O c 0 a C O '26L u cz d D u o , � L 0. a L � I — L 7 t. J J r'1 :J .... — 1 rte, "? �/, 1 '/ — _ .y _._ f I r•. _1 �/� �: f.- t — -_ r.� �J ..t �i �., 1 u I r c. J O C O C_ C O a L U CJ u .D O L 4 L U L U C C7 l Jf J IT tt — ".� J J J r f _ 411 r ^ :J I ^ ^ r � •n I G. i "J ice^ 2L v cl rJ o _ C CL �- p c o N „ ° U a p v� ° N cc _v CZ CJ V Con a g J c — Ca v o z cz E N cc � y fl v 2 v _ L V -fl QJ C Iad cc L c° ! n1 O Q C@ N m i J U C v Q " BUILDING PERMIT APPLICATION r. CITY OF ATLANTIC BEACH ?` FILE COP � fill800 Seminole Road,Atlantic Beach,FL 32233 :_ Office(904)247- 826 Fax(904)247-5845 -: m Permit Number: /-��dJ� 12 Job Address: 355 6 Street Atlantic Beach FL 32233 Legal Description 69 16-2S-29L 17 03101 Atlantic Beach Parcel: Floor Area of Sq.Ft. non1-hcated/cooled Valuation of Work$ Proposed Work heatedicooled (lass of Work(circle one): New Addition Alteration Repair More Demolition pool/spa window/door Ilse of existing/proposed structure(s)(circle one) Commercial Residential 777 If an existing structure,is a fire sprinkler system installed. (Circle one): Yes No N/A I'f Florida Product Approval ll For multiple products use pro uct approva orm rl Describe in detail the type of work to be performed: Addition and Remodel � J i Property Owner Information: Name: Katherrn Dalstleish,Willimn li BriggjA Address:355 61°ST Citv Atlantic Beach State: 1•L Lip: 32233 Phone E-Mail or Fax r(Optional) Contractor Information: Company Name:Bosco Building Contractors Inc Qualifying Agent:Todd Bosco I, Address 2158 Mgyport Rd City Atlantic Beach State FL 'Lip 32233 Office Phone 904-241-0320 Job Site/Contact Number 904-241-0320 Fax 1,904-241-0326 I State Certification/Registration CBC 1250212 Architect Name&Phone it Engineer's Name&Phone# I Fee Simple Title Holder Name and Address Bonding Company Name and Address Mortgage Lender Name and Address 4pphrntion is hereby,made to obtain a permit to do the work ani installations as indicated 1 certifi•that no work or installation has commenced poor w rhe issuance of a rmit and that all work will be performed to meet rhe standards of all laws regulating construction in this/unsddction. This perms becomes nu/lard void if work is not commenced within six(6)months,or rf construction or work is suspended or abandoned for a ppend of six(6)months at am time after work s commenced. I understand that separate permits must be secured for Mecmcd a ork Ptumbwe.Signs,Tt'ells,Pools,Furnaces, Badim Hearem,Tankt aid.tir Con&donm.etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.IF YOU INTEND TO OBTAIN FINANCING CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFR ERECORDING YOUR NOTICE OF COM1 herebv cenif-that 1 have read and examined this application and know the same to be true and correct..411 prom isions of laws and ordinances governing this tyre of work will be complied with whether specified herein or not. 77w granting of a permit does not presume to give outiprity to violate or cancel the provisions of any other fid rd,state I law regulating construction or the performamv of construction. Signature of Owner Signature of Contra Print Name Or Print Name Sworn to and subscribed before me Sworn to and subscribed bore me this��Day of r-1 rt/�.e� 20/s/ this �Day of�i� si- 20/-/ Notary Public Nota Public WILLIAM L.POPE W&LIA(uVJ 4�POPE Notary Public,State of Florida N ��I�c, tate of Florida My Comm,Expires Oct.19,2015 My Comm,Expires Oct 19,2M5 Commission No,EE 128745 Commission No.EE 128745 DO NOT WRITE BELOW- OFFICE USE ONLY Applicable Codes: 2010 FLORIDA RUILDNG CODE Review Result (circle one): Approved Disapproved Approved w/ Conditions Review Initials/Date: tA /Y Development Size Habitable Space y 2y s: J--. Non-Habitable Impervious area Miscellaneous Information Occupancy Group Type of Construction \/ 6 Number of Stories Zoning District R S - 2 Max. Occupancy Load Fire Sprinklers Required Flood Zone /V 11 Conditions/Comments: