1034 BIG PINE KEY MECH CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
pica j r
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
MECHANICAL HVAC PERMIT
MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814
JOB INFORMATION:
]ob ID: 14-MECH-642
]ob Type: MECHANICAL HVAC ONLY
Description: 2.5 TONS, 30k BTUS
Estimated Value:
Issue Date: 12/16/2014
Expiration Date: 6/14/2015
PROPERTY ADDRESS:
Address: 1034 BIG PINE KEY
RE Number: 172027-5058
PROPERTY OWNER:
Name: HEFFNER, PHILLIP L AND BARBARA,
Address: 1034 BIG PINE KEY
GENERAL CONTRACTOR INFORMATION:
Name: DONOVAN HEATING &AIR
Address: 315 SIXTH AVENUE S QA WILLIAM J DONOVAN
Phone: - -
PERMIT INFORMATION: Sticker for overcurrent protection must be on A/C equipment prior to
inspection. Failure to comply will result in a failed inspection and reinspect fees. No
exceptions.
FEES:
Furnaces and Heating $20.00
AC and Refrigeration $20.00
State Mech DBPR Surcharge $2.00
State Mech DCA Surcharge $2.00
Trade Permit Base Fee $55.00
Total Payments: $99.00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904) 247-5826 Fax (904) 247-5845
1011 ADDRESS:
r a 2 ne K PERMIT#
PROJECT VALUE $ 3 q DO ARI# 9 6 9 REQUIRED
Air Handling Equipment Only ' Air Handling Unit & Condenser Condenser Only
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
REQUIRED
Duct Systems: Total CFM
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity 1 Tons Per Unit 12,S f
Heat: Unit Quantity BTU's Per Unit 3dodd Seer Rating REQUIRED
Duct Systems: Total CFM
FIRE PREVENTION Re uires 3 sets of plans)
Quantity
Fire Sprinkler System Quantity ( q
(Requires 3 sets of plans)
Fire Standpipe Reuires 3 sets of plans)
Underground Fire Main Value (Requires
Quantity
Re uires 3 sets of plans)
(
Fire Hose Cabinets ( q
(Requires 3 sets of plans)
Commercial Hoods Quantity quires 3 sets of plans)
Fire Suppression Systems Quantity (Requires
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Boilers BTU's
Gas Piping Outlets Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
its application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name HC9ine
Phone Number 2Y7 - U-27—
Mechanical Company 00 e 0 �"'? 1 �`� Office Phone yl ids Fax
Co. Address: 215
f 11 5 City I► State Zip3 Z�
License Holder(Print): >>'a 1 w a State Certification/Registration#
Notarized Signature of License Holder
i.nYe RICHARD TOMPKINS Before me this��day o
I 20
:= Commission#FF 040399
• Expires July 29,zot�
Signature of Notary Public
s g
�R��•.• Baled Tku Troy Fain Ineaenu 800385-7019
Job:
Project Summary Date: December 10,2014
WrlghtSoft By: Aaron Thacker
Entire House
Donovan Heat&Air
315 6th Ave S,Jacksonville Beach,FL 32250 Phone:904-241-3765 Fax:904-241-3745 Email:aaron@donovanac.com Web:waw✓DonovanAC.com
For: Barbara Heffner
1034 Big Pine Key,Atlantic Beach, FL 32233
Notes:
Weather: Jacksonville Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions
39 'F Outside db 95 °F
Outside db 70 °F Inside db 75 'F
Inside db 31 °F Design TD 20 'F
Design TD Daily range L
50
Relative humidity
Moisture difference 53 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
11282 Btuh Structure 15262 Btuh
Structure 3308 Btuh Ducts 4672 Btuh
Ducts vent (0 cfm)0 Btuh Central 0 Btuh
Central vent (0 cfm) 0 Btuh Blower 0 Btuh
Humidification 0 Btuh
Piping 14590 Btuh Use manufacturers data n
Equipment load Rate/swing multiplier 1.00
Infiltration
Equipment sensible load 19934 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average 2253 Btuh
Fireplaces 0 Structure 997 Btuh
Ducts 0 Btuh
Heating Coolin Central vent (0 cfm) 3250 Btuh
Area (ft2) 1324 1321 Equipment latent load
Volume(ft')
11916.45 11916.23 23184 Btuh
Air changes/hour 0.45 0.23 Equipment total load
Equiv.changes/hour
AVF (cfm) 89 46 Req. total capacity at 0.70 SHR 2.4 ton
Heating Equipment Summary Cooling Equipment Summary
Make Tempstar
Make Tempstar
Trade 15 SEER N SERIES R410A HP
Trade 15 SEER N SERIES R410A HP Cond NXH530GKA"
Model NXH530GKA" Coil FXM4X30""A"
AHRI ref no3670844 AHRI ref no3670844
8.7 HSPF Efficiency 12.5 EER, 15.3 SEER
Efficiency Sensible cooling 20160 Btuh
Heating input 28600 Btuh @ 47°F Latent cooling 8640 Btuh
Heating output 27 'F Total cooling 28800 Btuh
Temperature rise 960 cfm Actual air flow 960 cfm
Actual air flow 0.066 cfm/Btuh Air flow factor 0.048 cfm/Btuh
Air flow factor 0 in H2O Static pressure 0 in H2O
Static pressure Load sensible heat ratio 0.86
Space thermostat
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
2014-Dec-11 14:43:11
_ + Wrl htSOtt Paget
9 Right-Suite®Universal 8.0.24 RSU05995
ACCK C:UJsers\Owner\Documents\Wrightsoft HVAC\Bogus 2.5 ton.rup Calc=MJ8 Front Door faces.E