Loading...
1034 BIG PINE KEY MECH CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD pica j r ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 MECHANICAL HVAC PERMIT MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: ]ob ID: 14-MECH-642 ]ob Type: MECHANICAL HVAC ONLY Description: 2.5 TONS, 30k BTUS Estimated Value: Issue Date: 12/16/2014 Expiration Date: 6/14/2015 PROPERTY ADDRESS: Address: 1034 BIG PINE KEY RE Number: 172027-5058 PROPERTY OWNER: Name: HEFFNER, PHILLIP L AND BARBARA, Address: 1034 BIG PINE KEY GENERAL CONTRACTOR INFORMATION: Name: DONOVAN HEATING &AIR Address: 315 SIXTH AVENUE S QA WILLIAM J DONOVAN Phone: - - PERMIT INFORMATION: Sticker for overcurrent protection must be on A/C equipment prior to inspection. Failure to comply will result in a failed inspection and reinspect fees. No exceptions. FEES: Furnaces and Heating $20.00 AC and Refrigeration $20.00 State Mech DBPR Surcharge $2.00 State Mech DCA Surcharge $2.00 Trade Permit Base Fee $55.00 Total Payments: $99.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 1011 ADDRESS: r a 2 ne K PERMIT# PROJECT VALUE $ 3 q DO ARI# 9 6 9 REQUIRED Air Handling Equipment Only ' Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating REQUIRED Duct Systems: Total CFM REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity 1 Tons Per Unit 12,S f Heat: Unit Quantity BTU's Per Unit 3dodd Seer Rating REQUIRED Duct Systems: Total CFM FIRE PREVENTION Re uires 3 sets of plans) Quantity Fire Sprinkler System Quantity ( q (Requires 3 sets of plans) Fire Standpipe Reuires 3 sets of plans) Underground Fire Main Value (Requires Quantity Re uires 3 sets of plans) ( Fire Hose Cabinets ( q (Requires 3 sets of plans) Commercial Hoods Quantity quires 3 sets of plans) Fire Suppression Systems Quantity (Requires FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Boilers BTU's Gas Piping Outlets Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read its application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name HC9ine Phone Number 2Y7 - U-27— Mechanical Company 00 e 0 �"'? 1 �`� Office Phone yl ids Fax Co. Address: 215 f 11 5 City I► State Zip3 Z� License Holder(Print): >>'a 1 w a State Certification/Registration# Notarized Signature of License Holder i.nYe RICHARD TOMPKINS Before me this��day o I 20 := Commission#FF 040399 • Expires July 29,zot� Signature of Notary Public s g �R��•.• Baled Tku Troy Fain Ineaenu 800385-7019 Job: Project Summary Date: December 10,2014 WrlghtSoft By: Aaron Thacker Entire House Donovan Heat&Air 315 6th Ave S,Jacksonville Beach,FL 32250 Phone:904-241-3765 Fax:904-241-3745 Email:aaron@donovanac.com Web:waw✓DonovanAC.com For: Barbara Heffner 1034 Big Pine Key,Atlantic Beach, FL 32233 Notes: Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions 39 'F Outside db 95 °F Outside db 70 °F Inside db 75 'F Inside db 31 °F Design TD 20 'F Design TD Daily range L 50 Relative humidity Moisture difference 53 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing 11282 Btuh Structure 15262 Btuh Structure 3308 Btuh Ducts 4672 Btuh Ducts vent (0 cfm)0 Btuh Central 0 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Humidification 0 Btuh Piping 14590 Btuh Use manufacturers data n Equipment load Rate/swing multiplier 1.00 Infiltration Equipment sensible load 19934 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average 2253 Btuh Fireplaces 0 Structure 997 Btuh Ducts 0 Btuh Heating Coolin Central vent (0 cfm) 3250 Btuh Area (ft2) 1324 1321 Equipment latent load Volume(ft') 11916.45 11916.23 23184 Btuh Air changes/hour 0.45 0.23 Equipment total load Equiv.changes/hour AVF (cfm) 89 46 Req. total capacity at 0.70 SHR 2.4 ton Heating Equipment Summary Cooling Equipment Summary Make Tempstar Make Tempstar Trade 15 SEER N SERIES R410A HP Trade 15 SEER N SERIES R410A HP Cond NXH530GKA" Model NXH530GKA" Coil FXM4X30""A" AHRI ref no3670844 AHRI ref no3670844 8.7 HSPF Efficiency 12.5 EER, 15.3 SEER Efficiency Sensible cooling 20160 Btuh Heating input 28600 Btuh @ 47°F Latent cooling 8640 Btuh Heating output 27 'F Total cooling 28800 Btuh Temperature rise 960 cfm Actual air flow 960 cfm Actual air flow 0.066 cfm/Btuh Air flow factor 0.048 cfm/Btuh Air flow factor 0 in H2O Static pressure 0 in H2O Static pressure Load sensible heat ratio 0.86 Space thermostat Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 2014-Dec-11 14:43:11 _ + Wrl htSOtt Paget 9 Right-Suite®Universal 8.0.24 RSU05995 ACCK C:UJsers\Owner\Documents\Wrightsoft HVAC\Bogus 2.5 ton.rup Calc=MJ8 Front Door faces.E