Loading...
364 7th St 2015 HVAC N C, 't IS\ CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 MECHANICAL HVAC PERMIT MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 15-MECH-64 Job Type: MECHANICAL HVAC ONLY Description: 1 cu 1 ahu 3 tons Estimated Value: Issue Date: 1/12/2015 Expiration Date: 7/11/2015 PROPERTY ADDRESS: Address: 364 7TH ST RE Number: 169901-0000 PROPERTY OWNER: Name: NOVAK, EMILY E Address: 364 7TH ST GENERAL CONTRACTOR INFORMATION: Name: DONOVAN HEATING & AIR Address: 315SIXTHAVENUES QA WILLIAM J DONOVAN Phone: - - PERMIT INFORMATION: Sticker for overcurrent protection must be on A/C equipment prior to inspection. Failure to comply will result in a failed inspection and reinspect fees. No exceptions. FEES: Furnaces and Heating $24.00 AC and Refrigeration $24.00 State Mech DBPR Surcharge $2.00 State Mech DCA Surcharge $2.00 Trade Permit Base Fee $55.00 Total Payments: $107.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 1011 ADDRESS: PERMIT# PROJECT VALUE $ ARI# �S 1'7q _REQUIRED Air Handling Equipment Only ��_Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit -3 Heat: Unit Quantity BTU's Per Unit TZ-00 Seer Rating Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read iis application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name f N\,.I u,� Phone Number Mechanical Company D". Office PhonQ2k )--n S�S Fax (�-ty'111414 '�Me R Zip 1 Co. Address:-3)-'> (alk Aa, Soj�r-6 ly License Holder(Print): Wh)'tcv-, State Certification/Registration# Notarized Signature of License Holder 20 IL4 RICHA777KINS Beforemethis ' 19L —dayof ACommission#FF 040399 ,�K' Expires July 29,2017 Signature of Notary Public '�j5 BwJed Th-Tmy Fm ln�nft 80M85-70n MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax (904) 247-5845 rOB ADDRESS: S 69 -7 PERMIT PROJ ,S I:Lq REQUIRED E CT VALUE S ARI# 6qr Air Handling Equipment Only X Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTLT's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTUs Per Unit-S'it00 Seer Rating 16, Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler Systern Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Pre-fabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalatons ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps # Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit boQorncs void if work does not commence within a six month period or wakissu-spcnded or abandoned for six months, I hereby certify that I have cd lis appliention and know the same to be tnic and correct. All provisions of laws and ordinances govcrning this work will bc complicd with whctlicr spccificd or ot. Tho permit docs not give atithority to violate the provisions of any other state or local law regulation construction or the performance ofconstruction, Property Owners Name Phone Number Office PhoneQ±L.-_-0 Mechanical Company L Co. Address:3)_1_-., 6d6 AVv� c�_p Q;r 6 Zip License Holder(Print): WhGoA-, State Certification/Registrationg Notarized Signature of License 1-folder I [':] —1.;� day of RICHARD TOMPKINS Before me this 20 1 L-) Commission#FF 040399 Expires July 29,2017 Signature of Notary Public DOM%ThA I Tay Foln 4w~ft 000.jB3.70n wrightsclift- Project Summary Job: Date: 1/12/15 Entim House By: Brandon Zahade Donovan Heat & Air 315 Gth Live sotfih,J=Monville Beach,rL 32250 Phone:R41-3785 Email:brande,@clonovanno,com -3 Mal 1111R* For: Novak 364 7th ST ATLANTIC BEACH, FL 32233 N ot es.- Design Information Weather, Jacksonville MayPort Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 *F Outside db 95 OF Inside db 68 OF Inside db 75 OF Design TD 29 OF Design TD 20 OF Daily range L Relative humidity 50 % Moisture difference 53 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17610 Stuh Structure 16031 Stuh Ducts 5848 Btuh D ucts 8534 Btuh Central vent (31 cfm) 997 Btuh Central vent (31 cfm) 688 Btuh Humidification 0 Stuh Blower 0 Btuh Pipigg 0 Btuh Equipment load 24454 Btuh Use manufacturer's data n Rate/swing multiplier 1,00 Infiltration Equipment sensible load 25253 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 2067 Btuh Ducts 1891 Btuh HeatV coolin Central vent (31 cfm) 1132 Stuh Area M2) 172 1729 Equipment latent load 5090 Stuh Volume(W) Iwo 15480 Air changes/hour 0.46 0.20 Equipment total load 30343 Btuh Equiv, AVF(cfm) 118 52 Req. total capacity at 0.70 SHR 3,0 ton Heating Equipment Summary Cooling Equipment Summary Make TEMPSTAR Make TEMPSTAR Trade Trade Model TXH536 Cond TXH536 ARI ref no. 6955179 Coll FXM4X36 ARI ref no. 6955179 Efficiency 8.5 HSPF Efficiency 15 SEER Heating input Sensible cooling 25253 Btuh Heating output 35896 Btuh @ 47OF Latent cooling 10823 Btuh Temperature rise 27 OF Total cooling 36076 Btuh Actual air flow 1203 cfrn Actual air flow 1203 cfm Air flow factor 0.051 cfm/Btuh Air flow factor 0,049 cfrn/Btuh Static pressure 0 in H20 Static pre�sure 0 in H20 Space thermostat Load sensible heat ratio 0.83 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. Right-SuReft Universal 7.1,01 R31JO5996 20 1&-J an-12 11:48:27 HVACQ Ton.rup Calc�MJ8 Orientation=N Pal)e I