364 7th St 2015 HVAC N C, 't IS\ CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
MECHANICAL HVAC PERMIT
MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814
JOB INFORMATION:
Job ID: 15-MECH-64
Job Type: MECHANICAL HVAC ONLY
Description: 1 cu 1 ahu 3 tons
Estimated Value:
Issue Date: 1/12/2015
Expiration Date: 7/11/2015
PROPERTY ADDRESS:
Address: 364 7TH ST
RE Number: 169901-0000
PROPERTY OWNER:
Name: NOVAK, EMILY E
Address: 364 7TH ST
GENERAL CONTRACTOR INFORMATION:
Name: DONOVAN HEATING & AIR
Address: 315SIXTHAVENUES QA WILLIAM J DONOVAN
Phone: - -
PERMIT INFORMATION: Sticker for overcurrent protection must be on A/C equipment prior to
inspection. Failure to comply will result in a failed inspection and reinspect fees. No
exceptions.
FEES:
Furnaces and Heating $24.00
AC and Refrigeration $24.00
State Mech DBPR Surcharge $2.00
State Mech DCA Surcharge $2.00
Trade Permit Base Fee $55.00
Total Payments: $107.00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904) 247-5826 Fax (904) 247-5845
1011 ADDRESS: PERMIT#
PROJECT VALUE $ ARI# �S 1'7q _REQUIRED
Air Handling Equipment Only ��_Air Handling Unit & Condenser Condenser Only
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit -3
Heat: Unit Quantity BTU's Per Unit TZ-00 Seer Rating
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
# Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read
iis application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name f N\,.I u,� Phone Number
Mechanical Company D". Office PhonQ2k )--n S�S Fax
(�-ty'111414 '�Me R Zip
1
Co. Address:-3)-'> (alk Aa, Soj�r-6 ly
License Holder(Print): Wh)'tcv-, State Certification/Registration#
Notarized Signature of License Holder
20 IL4
RICHA777KINS Beforemethis ' 19L —dayof
ACommission#FF 040399
,�K' Expires July 29,2017 Signature of Notary Public
'�j5 BwJed Th-Tmy Fm ln�nft 80M85-70n
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph (904) 247-5826 Fax (904) 247-5845
rOB ADDRESS: S 69 -7 PERMIT
PROJ ,S I:Lq REQUIRED
E CT VALUE S ARI# 6qr
Air Handling Equipment Only X Air Handling Unit & Condenser Condenser Only
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTLT's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTUs Per Unit-S'it00 Seer Rating 16,
Duct Systems: Total CFM REQUIRED
FIRE PREVENTION
Fire Sprinkler Systern Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Pre-fabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalatons
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
# Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit boQorncs void if work does not commence within a six month period or wakissu-spcnded or abandoned for six months, I hereby certify that I have cd
lis appliention and know the same to be tnic and correct. All provisions of laws and ordinances govcrning this work will bc complicd with whctlicr spccificd or
ot. Tho permit docs not give atithority to violate the provisions of any other state or local law regulation construction or the performance ofconstruction,
Property Owners Name
Phone Number
Office PhoneQ±L.-_-0
Mechanical Company L
Co. Address:3)_1_-., 6d6 AVv� c�_p Q;r 6 Zip
License Holder(Print): WhGoA-, State Certification/Registrationg
Notarized Signature of License 1-folder
I [':] —1.;� day of
RICHARD TOMPKINS Before me this 20 1 L-)
Commission#FF 040399
Expires July 29,2017 Signature of Notary Public
DOM%ThA I Tay Foln 4w~ft 000.jB3.70n
wrightsclift- Project Summary Job:
Date: 1/12/15
Entim House By: Brandon Zahade
Donovan Heat & Air
315 Gth Live sotfih,J=Monville Beach,rL 32250 Phone:R41-3785 Email:brande,@clonovanno,com
-3 Mal 1111R*
For: Novak
364 7th ST ATLANTIC BEACH, FL 32233
N ot es.-
Design Information
Weather, Jacksonville MayPort Naval, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 39 *F Outside db 95 OF
Inside db 68 OF Inside db 75 OF
Design TD 29 OF Design TD 20 OF
Daily range L
Relative humidity 50 %
Moisture difference 53 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 17610 Stuh Structure 16031 Stuh
Ducts 5848 Btuh D ucts 8534 Btuh
Central vent (31 cfm) 997 Btuh Central vent (31 cfm) 688 Btuh
Humidification 0 Stuh Blower 0 Btuh
Pipigg 0 Btuh
Equipment load 24454 Btuh Use manufacturer's data n
Rate/swing multiplier 1,00
Infiltration Equipment sensible load 25253 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 1 (Average) Structure 2067 Btuh
Ducts 1891 Btuh
HeatV coolin Central vent (31 cfm) 1132 Stuh
Area M2) 172 1729 Equipment latent load 5090 Stuh
Volume(W) Iwo 15480
Air changes/hour 0.46 0.20 Equipment total load 30343 Btuh
Equiv, AVF(cfm) 118 52 Req. total capacity at 0.70 SHR 3,0 ton
Heating Equipment Summary Cooling Equipment Summary
Make TEMPSTAR Make TEMPSTAR
Trade Trade
Model TXH536 Cond TXH536
ARI ref no. 6955179 Coll FXM4X36
ARI ref no. 6955179
Efficiency 8.5 HSPF Efficiency 15 SEER
Heating input Sensible cooling 25253 Btuh
Heating output 35896 Btuh @ 47OF Latent cooling 10823 Btuh
Temperature rise 27 OF Total cooling 36076 Btuh
Actual air flow 1203 cfrn Actual air flow 1203 cfm
Air flow factor 0.051 cfm/Btuh Air flow factor 0,049 cfrn/Btuh
Static pressure 0 in H20 Static pre�sure 0 in H20
Space thermostat Load sensible heat ratio 0.83
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
Right-SuReft Universal 7.1,01 R31JO5996 20 1&-J an-12 11:48:27
HVACQ Ton.rup Calc�MJ8 Orientation=N Pal)e I