Loading...
383 (385) Plaza 2014 convert to single family from duplex �J `S CITY OF ATLANTIC BEACH f 800 SEMINOLE ROAD J s) ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 RESIDENTIAL ADDITION MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 14-00001507 Job Type: RESIDENTIAL ADDITION Description: addition/convert duplex to single fam Estimated Value: $50,000.00 Issue Date: 11/20/2014 Expiration Date: 5/19/2015 PROPERTY ADDRESS: Address: 383 PLAZA RE Number: 170020-0000 PROPERTY OWNER: Name: OBRIEN, CHRIS R Address: GENERAL CONTRACTOR INFORMATION: Name: HARRINGTON REMODELING, INC Address: 12442 APPLE LEAF DR QA CHARLES HARRINGTON Phone: - - PERMIT INFORMATION: PUBLIC WORKS: Provide erosion and sediment control plans with installation details and maintenance schedule. Roll off container company must be on City approved list and container cannot be placed on City Right-of-Way. (Approved: Advanced Disposal, Realco, Republic Services, Shappelle's and Waste Management.) Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact Public Works (247- 5834) for Erosion and Sediment Control Inspection prior to start of construction. FEES: BUILDING PERMIT FEE $300.00 STATE DCA SURCHARGE $4.50 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. .j!.:11`1 j�j�� CITY OF ATLANTIC BEACH j 800 SEMINOLE ROAD J ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 PLAN CHECK FEES $150.00 STATE DBPR SURCHARGE $4.50 Total Payments: $459.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. TREE & VEGETATION AFFIL WIT, City of Atlantic Beach a Department of Community Development FILE COPY Planning&Zoning Division ;r 800 Seminole Road Atlantic Beach, FL 32233 `��/ (P)904 247-5800 (F) 904 247-5845 PERMIT# `/ SECTION I -APPLICANT INFORMATION F_ Owner_ F_ Legal Authorized Agent* NAME OF APPLICANT 1C ?�lN�- 7VIC-1 IZ_e9k NAME OF COMPANY ADDRESS OF COMPANY PHONE CELL EMAIL 0 CONTRACTOR CERTIFICATION NUMBER ATLBCH BUSINESS TAX RECEIPT NUMBER -/ L SECTION II-SITE INFORMATION / STREET ADDRESS OF PROPERTY [ rk Ifan address has not been assigned to this property,contact the AB Bu Department at (904)247-5826 to rert an address. LEGAL DESCRIPTION LOT BLOCK SUBDIVISION REAL ESTATE NUMBE LOT OR PARCEL SIZE: SQ FT AC RESIDENTIAL COMMERCIAL OTHER(SPECIE 1 affirm that 1 have reviewed the provisions of Cha r 23, "Protection of Trees and Native Vegetation" of the Municipal Code of Ordinances for the City of Atlantic Beach, FL and/or I ho articipated in a pre-applicatio.�, meeting with the Administrator of those regulations. Subsequently, 1 affirm that no regulated trees a no regulated vegetation wr:l be damaged, destroyed and/or removed from the above-described or adjacent properties in conjunction wt this project. SIGNATURE OF OWNER SIGN URE OF O 'ER Signed and sworn before me on this day of y State of County of Identification verified: Oath sworn: Yes J— No Notary Signature RFV-TVA-vIO.72 My Commission expires: .� n � � � .. max#sg19iT.MhN►. Yi);S _ t� ..• :A FILE C NOTICE OF COMMENCEMEW (PREPARE IN DUPLICATE) Permit No. t 7 — S 7 Tax Folio No. State of FG— County of (: To whom it may concern: The undersigned hereby informs you that improvements will be made to ce-rte ifi real property,and in accordance with Section 713 of the Florida Statutes,the following information is.stated in this NOTICE OF COMMENCEMENT. Legal description of property being improved:_OTI8 7 to L K �,C 393Is95 L 3Zz Address of property being improved: ST General description of improvements: AAA niw, �his, � �,��. D� 11� !� 1 sC C0hVe,V+ +W0 cd�.,O—i dvtole fa s) to 4=aJVIJJ4 Oil? l! ) ` Owner--... "J C�l�rets 2 Q331-,P,h Address_ ��3�'Z V210-1—A— Aft 13- (�_;L Owner's interest to site of the improvement Fee Simple Titleholder(if other than owner) Name Address 11� Contractor NA0.7` G Address Phone No. Fax No. Surety(if any) Address {`r /4 ount of bond$ Phone No. Fax No. Name and address of any person making a loan for the construction of the improvements. Name Address Phone No. Fax No. Name of person within the State of Florida,other than himself,designated by owner upon whom notices or other documents may be served: Name N Address Phone No. Fix No. In addition to himself,owner designates the following person to receive a copy of the Lienors Notice as provided in Section 713.06(2)(b),Florida Statutes.(Fill in at Owner's option). Name N yr{ Address Phone No. Fax No. Expiration date of Notice of Commencement(the expiration date is one(1)year from the date of recording unless a different date is specified): THIS SPACE FOR RECORDER'S USE ONLY WNER Signed: V" TE Before me this day of in the C tyofDwa at of Flo"a,has o lyap eared himself/herself and affirms that 211 statements and declarations herein in by O Doc#2014161973,OR BK 16850 Page 2436, are true and accurate Number Pages:1 "A til Recorded 07/21/2014 at 02:15 PM, z Ronnie Fussell CLERK CIRCUIT COURT DUVAL c COUNTY 3 RECORDING$10.00 NoaryPublfca Large,Stateof _ My commission expires: Counly of v Personally Known I or Produced Identification LOT 3/ BLOCK 11 bin LOT 39 LOT 35• BLOCK 11 50.00' (PLAT) BLOCK 11 N 83'38'1.3" E 0 49.99' (MEASURED) 0.0' _.. .,.., .. ., ....�,.:. . 0.; 0.1�y FILE COPY Lw I MASONRY LOT 38 N BLOCK 'I • ,pper •� f � a I � s RG ,�p pRoPa$�b WAIT LINE M e.�cIST. 1007 13Utt:.i71� r1 +� FU rijRe I M Q>Ro�[ a.. LOT 40 1-01 36 ULOCK 11I BLOCK 1 I ''`• 's.5' I w �NG� cr�tj a r Gds-�rpi.. o Two STORY ., ;n Vllz4ac,-Tloli 401z. 6d MASO61RY M cfl ry POSTED ��0.r 0 4",ra (sacra`-'- o #383 385 - - - o No c kA4jA;w>) � o.s ,� .e'-- io.�' i� 10.6' ---• 2::7�..- .��. ¢ v ,4 fLOCxt r OAL('QiY 20.-0*--- 1 � + �UJ.00' (PLAQ ly--— S 83.44'55" w 49.9'1' (MEASURED) PLAZA'. (av Wpff OF WAY) FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: O'BRIEN RESIDENCE Builder Name: HARRINGTON Street: 383 385 PLAZA STREET Permit Office: ATLANTIC BEACH City,State,Zip: ATLANTIC BEACH , FL,32233 Permit Number: Owner: Jurisdiction: Design Location: FL,Jacksonville 1. New construction or existing New(From Plans) 9. Wall Types(2216.3 sgft.) Insulation Area a. Frame-Wood, Exterior R=19.0 2216.30 ft2 2. Single family or multiple family Single-family b.N/A R= ft2 3. Number of units,if multiple family 1 c. N/A R= ft2 d. N/A R= ft2 4. Number of Bedrooms 3 10.Ceiling Types (431.0 sgft.) Insulation Area 5. Is this a worst case? No a. Under Attic(Vented) R=30.0 431.00 ft2 6. Conditioned floor area above grade(W) 626 b. N/A R= ft2c. N/A R= ft2 Conditioned floor area below grade(ft2) 0 11. Ducts R ft2 a. Sup: 1 st, Ret: 1 st,AH: 1 st 6 156 7. Windows(207.8 sgft.) Description Area 2 b. Sup: 2nd, Ret:2nd,AH:Attic 6 62.6 a. U-Factor: Dbl, U=0.47 207.83 ft SHGC: SHGC=0.31 ft2 12.Cooling systems kBtu/hr Efficiency b. U-Factor: N/A a.Central Unit 18.0 SEER:15.00 SHGC: b.Central Unit 6.0 SEER:15.00 c. U-Factor: N/A n2 SHGC: 13. Heating systems kBtu/hr Efficiency ft2 a. Electric Heat Pump 18.0 HSPF:8.00 d. U-Factor: N/A b. Electric Heat Pump 6.0 HSPF:8.00 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. 14.Hot water systems Area Weighted Average SHGC: 0.310 Cap:50 gallons a. Electric 8. Floor Types (623.9 sqft.) Insulation Area EF:0.920 a.Slab-On-Grade Edge Insulation R=0.0 430.70 ft2 b. Conservation features b. Floor Over Other Space R=19.0 193.20 ft2 None c. N/A R= ft2 15.Credits Pstat Total Proposed Modified Loads: 25.71 PASS Glass/Floor Area: 0.332 Total Standard Reference Loads: 32.60 Review of the Plans and OF�KE SrArF I hereby certify that the plans and specifications covered by this calculation are in ccomplia ce with the Florida Energy specifications covered by this ( � � �-� calculation indicates compliance Code. (ice' with the Florida Energy Code. Before construction is completed PREPAR0?) Y: this building will be inspected for 0 DATE: compliance with Section 553.908 � I hereby certify that this building, as designed, is in compliance Florida Statutes. C00 with the Florida Energy Code. OWNER/AGENT: BUILDING OFFICIAL: '} DATE: DATE: - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist 10/7/2014 1:16 PM 9Y 9 Ener Gau e®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5 PROJECT Title: O'BRIEN RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 626 Lot# Owner: Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: HARRINGTON Rotate Angle: 0 Street: 383 385 PLAZA STREE Permit Office: ATLANTIC BEACH Cross Ventilation: No County: Duval Jurisdiction: Whole House Fan: No City, State,Zip: ATLANTIC BEACH , Family Type: Single-family FL, 32233 New/Existing: New(From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL—JACKSONVILLE—INT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 FIRST FLOOR 431 8361.4 2 Block2 195 1560 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 1 st 431 8361.4 Yes 2 1 1 Yes Yes Yes 2 2nd 195 1560 No 1 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio 1 st 83.3 ft 0 430.7 ft2 ____ 0 0 1 2 Floor Over Other Space 2nd ---- ---- 193.2 ft2 19 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 454 ft2 72 ft2 Medium 0.9 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 431 ft2 N N 10!7/2014 1:16 PM 9Y 9 Ener Gau e0 USA-FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5 CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic(Vented) 1st 30 238 ft2 0.1 Wood 2 Under Attic(Vented) 2nd 30 193 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below At Ornt Tn Will Typee Ft In Ft In A r,-,q P-Vallle Fraction Absor 1 N Exterior Frame-Wood 1st 19 22 7 19 4 436.6 ft2 0 0.25 0.8 0 2 E Exterior Frame-Wood 1st 19 22 8 19 4 438.2 ft2 0 0.25 0.8 0 3 S Exterior Frame-Wood 1 st 19 22 7 19 4 436.6 ft2 0 0.25 0.8 0 4 W Exterior Frame-Wood 1st 19 22 8 19 4 438.2 ft2 0 0.25 0.8 0 5 N Exterior Frame-Wood 2nd 19 19 0 8 0 152.0 ft2 0 0.25 0.8 0 6 E Exterior Frame-Wood 2nd 19 10 2 8 0 81.3 ft2 0 0.25 0.8 0 7 S Exterior Frame-Wood 2nd 19 19 0 8 0 152.0 ft2 0 0.25 0.8 0 8 W Exterior Frame-Wood 2nd 19 10 2 8 0 81.3 ft2 0 0.25 0.8 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Wood 1 st None .2 .1 .1 .1 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 0.47 0.31 60.0 ft2 1 ft 0 in 1 ft 0 in None None 2 N 1 Vinyl Low-E Double Yes 0.47 0.31 60.0 ft2 1 ft 0 in 9 ft 0 in None None 3 E 2 Vinyl Low-E Double Yes 0.47 0.31 12.0 ft2 1 ft 0 in 9 ft 0 in None None 4 E 2 Vinyl Low-E Double Yes 0.47 0.31 30.0 ft2 1 ft 0 in 1 ft 0 in None None 5 W 4 Vinyl Low-E Double Yes 0.47 0.31 25.8 ft2 1 ft 0 in 1 ft 0 in None None 6 W 4 Vinyl Low-E Double Yes 0.47 0.31 20.0 ft2 1 ft 0 in 1 ft 0 in None None INFILTRATION # Scope Method SLA CFM 50 ELA Eq LA ACH ACH 50 1 Wholehouse Best Guess 0005 821 45.07 84.76 .474 4.965 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8 18 kBtu/hr 1 sys#1 2 Electric Heat Pump None HSPF:8 6 kBtu/hr 2 sys#2 10/7/2014 1:16 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 15 18 kBtu/hr 540 cfm 0.8 1 sys#1 2 Central Unit None SEER: 15 6 kBtu/hr 180 cfm 0.75 2 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None 1st 0.92 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC# V/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 1st 6 156ft2 1st 31 ft2 Default Leakage 1st (Default) (Default) 1 1 2 2nd 6 62.6 ft2 2nd 15.65 ft Default Leakage Attic (Default) (Default) 2 2 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Coolin Jan Feb ]Mar A r May Jun JXJ Jul Au Se Oct Nov Dec Heating f X Jan X Feb f X]Mar f AprMay f Jun Jul �Xj AuJXJ SeP �Xj Oct XNov XDec Ventin [ Jan Feb X Mar [ A r Ma Jun Jul Aug Se Oct X Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 1017/2014 1:16 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: 383 385 PLAZA STREET PERMIT#: ATLANTIC BEACH, FL, 32233 MANDATORY REQUIREMENTS SUMMARY-See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC-rated as meeting ASTM E 283. Windows and doors= 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors& outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat& 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced-air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 1 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 +accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of= 1 &Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor-retardant covers or a liquid cover or other means proven to reduce heat loss except if 70%of heat from site-recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82%after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat>10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 10/7/2014 1:16 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 79 The lower the EnergyPerformance Index, the more efficient the home. 383 385 PLAZA STREET, ATLANTIC BEACH, FL, 32233 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Frame-Wood, Exterior R=19.0 2216.30 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a. Under Attic(Vented) R=30.0 431.00 ft2 6. Conditioned floor area(ft2) 626 b. N/A R= ft2 7. Windows" Description Area c. N/A R= ft2 a. U-Factor: Dbl, U=0.47 207.83 ft2 11. Ducts R ft2 a.Sup: 1st, Ret: 1st, AH: 1st 6 156 SHGC: SHGC=0.31 b. Sup: 2nd, Ret:2nd, AH:Attic 6 62.6 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 18.0 SEER:15.00 SHGC: b.Central Unit 6.0 SEER:15.00 d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 18.0 HSPF:8.00 Area Weighted Average Overhang Depth: 1.000 ft. b. Electric Heat Pump 6.0 HSPF:8.00 Area Weighted Average SHGC: 0.310 8. Floor Types Insulation Area 14. Hot water systems a. Electric Cap:50 gallons a.Slab-On-Grade Edge Insulation R=0.0 430.70 ft2 EF:0.92 b. Floor Over Other Space R=19.0 193.20 ft2 b. Conservation features c. N/A R= ft2 None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building I THE ST Construction through the above energy saving features which will be installed (or exceeded) 4VO = gTFo in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: _ _ a t � C Address of New Home: City/FL Zip: 0010) 'Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. "Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software RODRIGUEZ Project Summary Job: 10614 energy g FIRST FLOOR Bate: Oct O6, DRI 014 ener consulting y: ERIN RODRIGUEZ -Project • • For: CHRIS O'BRIEN 383,385 PLAZA STREET, ATLANTIC BEACH, FL 32233 Notes: ADDITION Design Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 OF Outside db 92 OF Inside db 68 OF Inside db 74 OF Design TD 29 OF Design TD 18 OF Daily range L Relative humidity 50 % Moisture difference 60 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 11794 Btuh Structure 10222 Btuh Ducts 1782 Btuh Ducts 2601 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 13576 Btuh Use manufacturer's data n Rate/swing multiplier 0.97 Infiltration Equipment sensible load 12438 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1707 Btuh Ducts 630 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 431 431 Equipment latent load 2338 Btuh Volume (ft) 8335 8335 Air changes/hour 0.57 0.30 Equipment total load 14775 Btuh Equiv. AVF (cfm) 79 42 Req. total capacity at 0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make Generic Make Generic Trade Trade Model SEER 14.0, HSPF 8.1 Cond SEER 14.0, HSPF 8.1 AHRI ref Coil AHRI ref Efficiency 8.1 HSPF Efficiency 12.2 EER, 14 SEER Heating input Sensible cooling 13402 Btuh Heating output 19051 Btuh @ 47°F Latent cooling 5744 Btuh Temperature rise 27 OF Total cooling 19146 Btuh Actual air flow 638 cfm Actual air flow 638 cfm Air flow factor 0.047 cfm/Btuh Air flow factor 0.050 cfm/Btuh Static pressure 0.03 in H2O Static pressure 0.03 in H2O Space thermostat Load sensible heat ratio 0.85 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2014-Oct-07 12:48:57 wrightsoft Right-Suite®Universal 2012 12.1.08 RSU01508 Page 1 '�� ...ightsoft HVAC\Template\HARRINGTON-O'BRIEN.rup Calc=MJ8 Front Door faces: N RODRIGUEZ Project Summary Job: 10614 �y 9 SECOND FLOOR Bate: Oct R DRI 014 8Ctt3f COf1SJ11tf1 y: ERIN RODRIGUEZ Project Inf• • For: CHRIS O'BRIEN 383,385 PLAZA STREET, ATLANTIC BEACH, FL 32233 Notes: ADDITION Design Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 OF Outside db 92 OF Inside db 68 OF Inside db 74 OF Design TD 29 OF Design TD 18 OF Daily range L Relative humidity 50 % Moisture difference 60 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 2288 Btuh Structure 2891 Btuh Ducts 312 Btuh Ducts 490 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 2600 Btuh Use manufacturer's data n Rate/swing multiplier 0.97 Infiltration Equipment sensible load 3279 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 455 Btuh Ducts 129 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 195 195 Equipment latent load 584 Btuh Volume (ft') 1558 1558 Air changes/hour 0.81 0.43 Equipment total load 3863 Btuh Equiv. AVF (cfm) 21 11 Req. total capacity at 0.70 SHR 0.4 ton Heating Equipment Summary Cooling Equipment Summary Make Generic Make Generic Trade Trade Model SEER 14.0, HSPF 8.1 Cond SEER 14.0, HSPF 8.1 AHRI ref Coil AHRI ref Efficiency 8.1 HSPF Efficiency 12.2 EER, 14 SEER Heating input Sensible cooling 3648 Btuh Heating output 5186 Btuh @ 47°F Latent cooling 1563 Btuh Temperature rise 27 OF Total cooling 5212 Btuh Actual air flow 174 cfm Actual air flow 174 cfm Air flow factor 0.067 cfm/Btuh Air flow factor 0.051 cfm/Btuh Static pressure 0.03 in H2O Static pressure 0.03 in H2O Space thermostat Load sensible heat ratio 0.85 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 57 wrightsoft Right-Suite®Universal 2012 12.1.08 RSU01508 2014-Oct-07 1z:as:e 2 Page 2 ightsoft HVAC\Template\HARRINGTON-O'BRIEN.nip Calc=MJS Front Door faces: N � ' � � I o N fD m o o' �* �1 WSJ � 0 0 N cnCL Q UP' OCC C 00 N p Q••CD N � n b Q , cu ►s r � O d o0 o � k cD N y ce C�7 C3- ncs c CD o CD*ft CD O CD Ho g CD fD b n ZM n � 1 4if "O 00 -1 7* cn A W N - /b -. p �nO !0770 -,l a, kA P W O O CD O O O O O O v r .-- r+ O ... C�. CD Cs CD +� �„ cD �, cD C/� r � CD T3 CD i� P� UQ v' UQ CD CY UQ Prr O O �.. cn .-r CDaq CD L CD UQ O r A �. UQ A� UQ � .. 0 CD " CD OCD O CD, LS UQ .� ,1+ (� CD CD oaq H C i 9 � a A I � A b O a : o A � d A F! O C3 o 0 ci A CD 1H r' 0 A A7 i a OI'D 00 J C-4 LA P wN ��, o y J 01 (A M led _ 1CL O cn En rA CD C/1 A O N i--. CD I y fD n O CD O (n k CD cn O Qn A7 k 1( A Y � r A a b O y 02+ 2 � sdC d O' i O II 1 n I A7 r� - B l 1 � P ti CD y� trJ CD CD CDCD aCD cn cr, N va o ''d y CD 0 eD e 0 CD CD CD CL LJ C CD CL CD 0 0 � CD CD o 0 to CD �a CD CD 0. 0 CD cr CL CD ^ O C ^N\ , al \v C CD 4 C O CCL o n D' I o � � C" CSD � O O �, rs CD ,y lu�omf w�•ae•nM •r �� "1� "�} � `11d 1S `Vzvl,� ool"*Z�YO6) IM4S WI0.L 41^oS oZ► a xoisR •Ioaaadoxs NMI Vo1M0,� 'H�vaa 91OWIMIs)1�Ir �J�j ` I Ou yi a ad lL�OjON� os��sra is OY[Hl'S oZs Ge�*`,P�� �J .L�311HDUV AMAJ 3A iY O ate. p o ol 44 p u _i N � I I I o5ab FILE COPY -- wALJ- r J t;x- b6��tiN �\ Ll 11 �-T I ~- I AUPMIDrl PCK'T F � P.vv�TlDhl i�f�Of�OSI�l� �D DITID� I�OI� LA2-VERMEY ARCHITECT 420 B.THIROI 8T. 2461150 CJAKBONVILIE BEACH. FLORIDA C HR` j I BEN BROADFOOT•DESIGN 4J South w� `� �`°° /ATL I-V � �PLAZA �'�O x :r CITY OF ATLANTIC BEACH Building Department 800 Seminole Road �'� Atlantic Beach,Florida 32233 (904)247-5800 ' FILE C PLAN REVIEW COMMENTS Permit Application # /q `l 5-0.7 Property Address: 3 3 i lq ,�-L-Ly Applicant: i h!C/0 n Project: '(—'0/)(/-P ,4 v 1,Pd �'� Room aP64heln This permit application has been: F-1 Approved Reviewed and the following items need attention: r 1T Please re-submit your application when these items have been completed. Reviewed By: /Ir iI Date: --- j, City of Atlantic Beach I APPLICATION NUMBER Building Department artment o be assigned by t =B�� D rtment.) 800 Seminole Road U4 Atlantic Beach, Florida 32233-5445 / (19 ; Phone (904)247-5826 • Fax(904)247-5845 ;j�j 2 E-mail: building-dept@coab.us tate routed: '{ -- City web-site: http://wwwcoab.us p� -- - APPLICATION REVIEW AND TRACKING FORM Property Address: pz Department review required Yes No h4 , uildin arming Zone Applicant: /��, D /7 to r ;ublic enn r.:' r i Project: -5 blic Wc:r - � �40 �� ✓�� Ui!_ ty rD Public Sai-�,ty Al / i,4je Fire SeiVoCas Review fee $ Dept Signature Other Agency Review or Permit Required Review or Recc of Permit Verified' 3f' ®ate Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: roved. ❑Denier (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by:_ Date: TREE ADMIN. Second Review: []Approved as revised. ❑De iec PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: Reviewed by: Date- Revised 05/14/09 City of Atlantic Beach APPLICATION NUMBER 111s r ` Building department _ i (To be assigned by t »B � rtment.) 800 Seminole Road RECEIVED / Atlantic Beach, Florida 32233-5445777 / r~ Phone (904)247-5826 • Fax(90 4) 247-f"? 122014 E-mail: building-dept@coab.us L Date routed: City web-site: http://www.coab-us - Ii -- - APPLICATION REVIEW AND TRAC" -ING FORM Property Address: c5O� Z Depart nt review required Yes No uildin Applicant: /'/ A r7 anninc Zone c' cc ree c rator LL .�'! G blic V, Project: L ublic Utilities Public Sa=ety !AI /-i.4j Fire Seivit:es Review fee $ Dept Signature Review or Recti,.'.,,, Other Agency Review or Permit Required of Permit Verified ®ate Florida Dept.of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. ❑Denie.,:i. (Circle one.) Comments: BUILDING PLANNING &ZONING Reviewed by: Date: TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied ALC'WOR S Comments: UTI PUBLIC SAFE Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. []Denied. Comments: Reviewed by: Date: Revised 05/14/09 City of Atlantic Beach APPLICATION NUMBER �s i. Building Department y_ o be assigned by t e Bu�� rtment.) ltil r�AiR�� � 800 Seminole Road Atlantic Beach, Florida 32233-5445 / % Phone (904)247-5826 - Fax(904) 247- 845 SEP 12 2014 E-mail: building- p @ de t coab.us L Date routed: City web-site: http://www.coab.us APPLICATION REVIEW AND TRACHNG FORM Property Address: 0 �jI�,Z G� Departr, ent review required Yes No AA A Id k uildin 77r,r'inZoni Applicant: /�� ree rator Project: .3-1 L�� eV1lar 'L /1ed QM Abb;1 I� , as Public S '-1I . r Al r lA e , Fire Se, s Review fee $ Dept Signature Review or Recc Other Agency Review or Permit Required Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation ^ St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Approved. [_]Denier (Circle one.) Comments: BUILDING PLANNING &ZONING Date: Y.3� I Reviewed by: _�� TREE ADMIN. Second Review: ❑Approved as revised. ffDenied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: Reviewed by. Date: Revised 05/14/09 Cit of Atlantic Beach APPLICATION NUMBER �s s Building Department (To be assigned by7 t e Bu�D rtment.) 800 Seminole Road / yy(//} r� Atlantic Beach, Florida 32233-5445 ((( Phone (904)247-5826 • Fax(904) 247-5845 E-mail: building-dept@coab.us Date routed: City web-site: http://www.coab,us APPLICATION REVIEW AND TRACKING FORM Property Address: z GLr Department review required Yes No uildin Applicant: /'/ r7&9 PTanning &Zoni ree rator Project: � blic Wor • ublic Utilities 2) A60 om ,9-aAr�i� Public Safety ,�` rJA� Fire Seii�ices ,V Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. XDeniedl. (Circle one.) Comments: SGG A44 Q L 4, �dn," fcP4 BUILDING PLANNING &ZONING Reviewed by: _ l/ Date: TREE ADMIN. Second Review: KApproved as revised. ❑Denied PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: (/ Date: cC; FIRE SERVICES Third Review: []Approved as revised. []Denied- Comments: Reviewed by: Date: Revised 05/14/09 FORM 405-10 FILE COPY ' FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: O'BRIEN RESIDENCE Builder Name: HARRINGTON Street: 383 385 PLAZA STREET Permit Office: ATLANTIC BEACH REVISED City, State,Zip: ATLANTIC BEACH , FL,32233 Permit Number: A 8 Owner: JurisdictionO C"T a4 Design Location: FL,Jacksonville 1. New construction or existing New(From Plans) 9. Wall Types(2216.3 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Frame-Wood, Exterior R=19.0 2216.30 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (431.0 sqft.) Insulation Area a. Under Attic(Vented) R=19.0 431.00 ft2 6. Conditioned floor area above grade(ft2) 626 b. N/A R= ft2 c. N/A R= ft2 Conditioned floor area below grade(ft2) 0 11. Ducts R ft2 7. Windows(207.8 sgft.) Description Area a. Sup: 1st, Ret: 1st,AH: 1st 6 156 a. U-Factor: Dbl, U=0.47 207.83 ft2 b. Sup: 2nd, Ret:2nd, AH:Attic 6 62.6 SHGC: SHGC=0.31 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency a. Central Unit 18.0 SEER:16.00 SHGC: b. Central Unit 6.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 18.0 HSPF:8.00 SHGC: b. Electric Heat Pump 6.0 HSPF:8.00 Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.310 14. Hot water systems a. Electric Cap:50 gallons 8. Floor Types (623.9 sgft.) Insulation Area EF:0.920 a.Slab-On-Grade Edge Insulation R=0.0 430.70 ft2 b. Conservation features b. Floor Over Other Space R=19.0 193.20 ft2 None c. N/A R= ft2 15. Credits Pstat S Total Proposed Modified Loads: 25.53 PASS Glass/Floor Area: 0.332 11.77 Total Standard Reference Loads: 32.60 1 hereby certify that the plans and specifications covered by Review of the plans and O�11JE Sr,42F this calculation are in compliance wit the Florida Energy specifications covered by this Code. �/v R�1 Z calculation indicates compliance ` with the Florida Energy Code.00 PREPARED B Before construction is completed DATE: this building will be inspected for a compliance with Section 553.908 I hereby certify that this building, as desi ed, is in compliance Florida Statutes. with the Florida Energy Co COD WE OWNER/AGENT: BUILDING OFFICIAL DATE: DATE: - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist 3/27/2015 9:41 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5 w• PROJECT Title: O'BRIEN RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 626 Lot# Owner: Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: HARRINGTON Rotate Angle: 0 Street: 383 385 PLAZA STREE Permit Office: ATLANTIC BEACH Cross Ventilation. No County: Duval Jurisdiction: Whole House Fan: No City,State,Zip: ATLANTIC BEACH , Family Type: Single-family FL, 32233 New/Existing: New(From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL—JACKSONVILLE—INT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 FIRST FLOOR 431 8361.4 2 Block2 195 1560 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 1st 431 8361.4 Yes 2 1 1 Yes Yes Yes 2 2nd 195 1560 No 1 2 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio 1 st 83.3 ft 0 430.7 ft2 ___- 0 0 1 2 Floor Over Other Space 2nd ---- ---- 1932 ft2 19 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 454 ft2 72 ft2 Medium 0.9 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 431 ft2 N N 3/27/2015 9:41 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5 CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic(Vented) 1st 19 238 ft2 0.1 Wood 2 Under Attic(Vented) 2nd 19 193 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 Pt In Et In Area R-\/al,le Erarton AhSnr C, 1 N Exterior Frame-Wood 1 st 19 22 7 19 4 436.6 ft2 0 0.25 08 0 2 E Exterior Frame-Wood 1st 19 22 8 19 4 438.2 ft2 0 0.25 0.8 0 3 S Exterior Frame-Wood 1st 19 22 7 19 4 436.6 ft2 0 0.25 0.8 0 4 W Exterior Frame-Wood 1st 19 22 8 19 4 438.2 ft2 0 0.25 0.8 0 5 N Exterior Frame-Wood 2nd 19 19 0 8 0 152.0 ft2 0 0.25 0.8 0 _ 6 E Exterior Frame-Wood 2nd 19 10 2 8 0 81.3 ft2 0 0.25 0.8 0 _ 7 S Exterior Frame-Wood 2nd 19 19 0 8 0 152.0 ft2 0 0.25 0.8 0 8 W Exterior Frame-Wood 2nd 19 10 2 8 0 81.3 ft2 0 0.25 0.8 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Wood 1st None .2 .1 .1 .1 ft2 WINDOWS Orientation shown is the entered. Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 0.47 0.31 60.0 ft2 1 ft 0 in 1 ft 0 in None None 2 N 1 Vinyl Low-E Double Yes 0.47 0.31 60.0 ft2 1 ft 0 in 9 ft 0 in None None 3 E 2 Vinyl Low-E Double Yes 0.47 0.31 12.0 ft2 1 ft 0 in 9 ft 0 in None None 4 E 2 Vinyl Low-E Double Yes 0.47 0.31 30.0 ft2 1 ft 0 in 1 ft 0 in None None 5 W 4 Vinyl Low-E Double Yes 0.47 0.31 25.8 ft2 1 ft 0 in 1 ft 0 in None None 6 W 4 Vinyl Low-E Double Yes 0.47 0.31 20.0 ft2 1 ft 0 in 1 ft 0 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess .0005 821 4507 84.76 .474 4.965 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8 18 kBtu/hr 1 sys#1 2 Electric Heat Pump None HSPF:8 6 kBtu/hr 2 sys#2 3/27/2015 9:41 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 16 18 kBtu/hr 540 cfm 0.8 1 sys#1 2 Central Unit None SEER: 16 6 kBtu/hr 180 cfm 0.75 2 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None 1 st 0.92 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 1 st 6 156 ft2 1 st 31 ft2 Default Leakage 1 st (Default) (Default) 1 1 2 2nd 6 62.6 ft2 2nd 15.65 ft Default Leakage Attic (Default) (Default) 2 2 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb Mar ( ]A r May Jun �Xj Jul �Xj Au Se Oct Nov Dec HeatinlX Jan X Feb �X�Mar I ]Apr May t Jun Jul Au �Xj Sep �Xj Oct Nov �Xj Dec Ventin [ Jan [ Feb X Mar X A r [ Ma Jun Jul Aug Se Oct [X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 3/27/2015 9:41 AM EnergyGaugeO USA-FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5 FORM 405-10 • Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: 383 385 PLAZA STREET PERMIT#: ATLANTIC BEACH, FL, 32233 MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC-rated as meeting ASTM E 283. Windows and doors= 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors& outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat& 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced-air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. —_ Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 / + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 1403.9 Pool pumps and pool pump motors with a total horsepower (HP) of= 1 &Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor-retardant covers or a liquid cover or other means proven to reduce heat loss except if 70%of heat from site-recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82%after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or / variable capacity system. Electric heat>10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 3/27/2015 9:41 AM EnergyGaugeO USA-FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 78 The lower the EnergyPerformance Index, the more efficient the home. 383 385 PLAZA STREET, ATLANTIC BEACH, FL, 32233 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area a. Frame-Wood, Exterior R=19.0 2216.30 ft2 2. Single family or multiple family Single-family b. N/A R= ft2 3. Number of units,if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a. Under Attic(Vented) R=19.0 431.00 ft2 6. Conditioned floor area(ft2) 626 b. N/A R= ft2 c. N/A R= ft2 7. Windows" Description Area 11. Ducts R ft2 a. U-Factor: Dbl, U=0.47 207.83 ft2 a. Sup: 1st, Ret:1st, AH:1st 6 156 SHGC: SHGC=0.31 b. Sup: 2nd, Ret:2nd,AH:Attic 6 62.6 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 18.0 SEER:16.00 b. Central Unit 6.0 SEER:16.00 SHGC: d. U-Factor: N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 18.0 HSPF:8.00 Area Weighted Average Overhang Depth: 1.000 ft. b. Electric Heat Pump 6.0 HSPF:8.00 Area Weighted Average SHGC: 0.310 8. Floor Types Insulation Area 14. Hot water systems a. Electric Cap:50 gallons a. Slab-On-Grade Edge Insulation R=0.0 430.70 ft2 EF:0.92 b. Floor Over Other Space R=19.0 193.20 ft2 b. Conservation features c. N/A R= ft2 None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building 1'0�JOE sr4 Construction through the above energy saving features which will be installed (or exceeded) - in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Wolf Builder Signature: Date: tr Address of New Home: City/FL Zip: cOLD) p5� WE 'I j *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) ) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software s'