5809 Fleet landing Blvd 2015 jacczi tub elec/plumb CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 PLUMBING PERMIT MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 15-PLBG-270 Job Type: PLUMBING ONLY Description: REPLACE TUB W/ JACUZZI WALK IN Estimated Value: $15,000.00 Issue Date: 2/5/2015 Expiration Date: 8/4/2015 PROPERTY ADDRESS: Address: 5809 FLEET LANDING BLVD RE Number: LOC ID-0000 PROPERTY OWNER: Name: NAVAL CONTINUING CARE Address: 1 FLEET LANDING BLVD 1 FLEET LANDING BLVD GENERAL CONTRACTOR INFORMATION: Name: F W DUKES PLUMBING LLC Address: 4730 N W 68Th ST Phone: - - FEES: State PLMG DBPR Surcharge $2.00 State PLMG DCA Surcharge $2.00 Trade Permit Base Fee $55.00 Building Flat Rate Fee $125.00 Total Payments: $184.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. FAIRBANKS CONSTRUCTION 1720 NW 4th Ave Suite 100 Ocala,FL 34475 NOTICE OF COMMENCEMENT State of Florida PERMIT#: County of. DUVAL Tax Folio/Parcel ID: 169397-0200 THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with chapter 713, Florida Statutes.The following information is provided in the notice of commencement: 1)Description of property: 05-2S-29E 70.418 PT FRAC SEC 5-2S-29E RECD 2)General description of improvements: INSTALL WALK IN BATHTUB WITH ELECTRIC 3)Owner Name: NAVAL CONTINUING CARE RETIREMENT FOUNDATION INC 4)Address: 5809 FLEET LANDING BLVD,ATLANTIC BEACH,FL 32233 5)Name&Address of fee simple titleholder:(If other than owner) Interest in property:N/A 6) Contractor:(Qualifier name&address):Fairbanks Construction Charles G.Fairbanks Jr. 1720 NW 4th Ave.#100 Ocala,FL 34475 7) Surety:Name and address: n/a Amount of bond$ n/a 8)Lender:(name&address) n/a 9)Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by section 713.13(1)(a),Florida statutes:(name&address) n/a 10)In addition to himself,Owner designates the following person(s)to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes:(name&address) n/a 11)Expiration date of Notice of Commencement(the expiration date is 1 year from the date of recording unless a different date is specified) WARNING TO OWNER:ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,PART I,SECTION 713.13,FLORIDA STATUES,AND CAN RESULT IN YOUR PAYING TWICE FOR I MPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION.IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTO Y BEFORE COMMENCNG WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. ign a of er or Owner's Authorized Signatory's Title/Office icer/Director/Partner/Manager The foregoing instrument as acknowledged before me this 3 day of .w.ny,20•../ by (name of person)as ' � (type of . authority........e.g. officer,trustee,attorney in fact)for Ao/4,,,tr- l„,,,1 4r*/-e;7Xrgr-y, (name of party on behalf of whom instrument was executed). Fa my;µ . SHARI R QUEST MY COMMISSION#FF068247 (Seal) ... ' Signature Pub} &aa�yg „�I jjj a Print,Type or Stamp C961mtssioned Name of Notary Public Personally Known % or Produced Identification Verification Pursuant to Section 92.525,Florida Statues Under penalties of perjury,I declare that I have read the foregoing and that the facts stated in it are true to best of my knowledge and belief. Doc 4 2015025440,OR SK 17054 Page 549. Signature of Natural Person Signing Above Number Pages: i Recorded 02 03/2015 at 12:22 PM, Ronnie Fussell CLERK CIRCUIT COURT DUVAL COUNTY RECORDING$10.00 ELECTRICAL PERMIT Appi.TCA1QN Crry Ur ATLANTIC BEAC 900 Seminole Rd,Atlantic Bcach, FT 32233 Ph (404)247-5826 Pax (904)247,3845 JoB ADDRESS: ��Q � �' I Y �I C R, PERMI:I # JEA INFORMATION REQUTREll ON ALL PERMITS AMPS VOLTS PUASE VALUE, OF WORK S T76-0 NEW SERVICEEj Y Ovcritead ❑ Underground Q1 Und �k-gromrd up Pole ❑Residential(Main) Service 00-100 amps [3101-150amps [1151-200ttinps Q amps #of Meters ClCommercial (Main)Serviee I t0-100 amps 110'1-150amps 0151-200�mps fl amps UCT Service amps Conductor Type Size i DMulti-Family(Main)Service ❑0-100 amps ❑101-150amps 0151-200amps I I Nmps #of Unit Meters ❑Temporary Pole ❑ nrtrps SERVICE UPGRADE I I nmps ❑ CT Service ]snips NEW FEEDER(ADDITIONS,ACCESSORY STRUC'T'URES,ETC.) I 1100 amps C I50amps 0200anips ❑ amps OCT Service am �J ADDITIONS,REMODELS,RRPAII2S,BUILD-OUT'S,ACCESSORY ST12U UI1E5,ETC. U �S DutletglSwitches:2 00 ZO 0-30ampy 31-100amps 101-200anips •03 Appliances: 0-30amps 31-I00atmps 101-200anrps A/C Circuits: _ 0-60nntps _61-100umps U`y Heat Circuits: 4 circuits Qa . kw Number of Lighting Outlets, Including fixtures: ! �` OTHER ELECTRICAL PROJECTS ❑Swimming Pool CI Sign ❑Smolce Detectors_Qty ❑Transformers TVA 0Motors hp FIRE ALARM SYSTEM (Requims 3 seta of plans) Qty volts/limps 1 LUE OF W0kK S REPAIRS/MISCELLANEbUS I ]Replace Bumt/Damaged Meter Can ❑Safetylnspection 1 ]Panel hange 0O to UG CdOther: l� 'f rid l I lam' Permit bcoomn void if work dotes not uommcnec within a slx month period or work I's suspcndcil or unduncd for sIx months. I hereby certify that I have read ibis upplic Mion and know the same to be tntt turd correct. All provisions of lava turd ordihittiec governing this work will Inc complied with whether specified or nut. The permit doen not give authority to violate the provisions of any oilier swo or lou l lttw regontion oonstruction or t}c performance of Cog9tnulion. r' q ,) Property Owners NameNAVQI t?i>rtlinui lv�dcirt.tt�it'trnt�rF wt,lt*R�ioh� 1nG�l,hone Number !U`�"v2 P `�9dd Electrical Company VOW '�lf'CJbC t�� Oi7ice'i hone,, •• d?`!'07� 1�IFri�c,35o1' '(P?•q-);:DG Co.Address: �7 90 h` '� City 11 �1J� State ]+ "Lip License Holder(Print): v 1-er State ' ieation/Registradon 4 60,16001 V7� Notarized Signature of License Holder11 '7� Sworn and sttbseribed before me this �I d f 20 RICHARD L RAGLE *� c* MY COMMISSION a EE 865476 Signature of Notary Public EXPIRES:January 21,2017 �rql off° BOftdld Thru BvApot Nataty Services ' FOFF 1720 uiteN.W.4thAvenue 1. fl, IROANKS WALK-tN TUB SPECS Suite 100 �+ arra°rrrwe�§'? ';t7.1Ocala,FL 34475ILE _ __...._Phone(352)732-8600 r O 61 C�T U I (�1ION15010-.- Fax Toll Free(800)743-8601 U-1 J I R u t, Jop# 50 (� Fax(352)732-0069 9 Uirr.sion(#Fairbanks Cnnrracling and Remodeling,Inc. FairbanksConstruction.com6aa+a a #CRC050304 - HC0002524 Customer : W 04 rrnee S 5S0°I a 914 414W41L Date: lb'�� NOTE: Items must be marked to be included WORK TO BE DONE �/ Jacuzzi Model DFS Walk-in Tub lo/ Air Jets: Lifetime Warranty: Ea Color: ( ite DAImond Ozone Generator:,/ Door Frame R&R: J✓ * Door: Left El Right Aromatherapy: L�,,, , Wall System Color: Chrome Faucet: d Chromotherapy: Wall System Style: Hand Held Spray: Tub Extension: Extra Grab Bar: In-Line Heater: Basic Electrical: Hydro Jets: Delivery: ADDITIONAL NOTES: tq ..�,��.. ...s 1.v.,AfYJ ... ... ... ... ... ... ... ... . + +rt?► :!y ! ... ... ... ... ... ... .. .. . . ... ... ... ... ... S! ... ... ... ...?-r1 ! e ..N. !^I.. �.�. .. .. 6 !5 "t ... ... �" r� .. , .. ... ... ... ... ... ... ... ... ... ... ... ... .. ... .. . ... . .. r- :: ... ... ... ... ... ... .. a�: ... ..x" h 3::: ::: ::: :: ::: ::: ::: ... ... . :: ::::: ej ... ... ... ... . .ve'5 ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ..... . '`� ... .. .. ... . .. ... ... . .. ... ... . ... ... ... ... ... ... ... ... ... ... ... ..... 1.� .. i0. :I;�...s. :�l: . .a f. ...�a�s.. 7. . ... ... ... ... ... ... ... ... ... ... ..... z,� . .�.�. ..�. . ..>~ . ..���w.. ... ... ... ... ... ... ... ... .. �,.. . ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ..... ` .. ... ... ... ... ... .. .. ... ... ... ... ... ... ... ... ... ... ... ... ... .. Wl r..` . ..i ., .. ... ... ... ... ... ... ... ... ... ... ... ... ..... l.N. ... '/.S. ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... .. ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... CUSTOMER SIGNATURE_N�__pwVvv 1 ---- DATE Rev.6/10/13 1720 N.W.4th Avenue Suite 100 FAIRRANKSOcala,FL 34475 S �t�CUZZ��Phone(352)732-8600 , _ Toll Free(800)743-8601 CONSTRUCTION Walk In Tub Contract Fax 352)732-0069 www.FairbanksConstruction.com i oiv+mon n(trurhank.v cmarac+ing and Ri+ruxleln{4,Inc ) O /O / #CRC05 304 - 11CO002524 Job# Sold To: (�Cv rf-1s t� Phone: + ' y��3 Dater Physical Address: -�4©9 f'I�@ FI rH� Blvd City: C7TJIYi P t Ee,i State: << Zip: Mailing Address : S 7'�'� City: State: Zip. (if djejent fr9m physical address,otherwise'same') Email: Approx Start Date: 7-9 weeks Approx Finish Date: 1-3 days SG 1elez (-/,,<0140L �v , (from permit obtained date,if required) (from start date) The undersigned Seller hereby sells and the undersigned BUYERS hereby purchases. If one or more of them,jointly and severally, the below described goods and services for the price and upon the terms and conditions set forth herein. WORK TO BE DONE NOTE: ITEMS NOT MARKED ON CONTRACT ARE NOT INCLUDED Jacuzzi a Combination Walk-In Tub Includes: 10 Hydro Therapy Jets, 16 Airjets,Inline Heater,Ozonator, Aromtherapy,Chromtherapy,Chrome Faucet&hand-held sprayer Model: eluxe 5229 ❑Comfort 3732 ❑Grand 5433 Jacuzzi e Classic Walk-in Tub Includes:6 Hydro Therapy jets,Inline Heater,Chrome faucet&hand-held sprayer. Model: ❑ Classic 5229 ❑Classic Grand 5433 O tions: Co r: Doo Swing: Wall System: El e rical: Life ' e Warranty: hie [ eft ❑StyleBasic Electric ncluded ❑ and ❑Right ❑Color, ❑Electric Sub Panel Door Frame: ub Trim Extension ❑Additional Grab bars# ❑Remove and reinstall ELECTRICAL Fairbanks Construction contracts electrical work to licensed Electricians. Install includes basic electrical circuits ONLY to 75 feet from existing panel and ONLY with spare circuit(s)in panel. If no spares or distance is farther or other work is needed,additional charges will apply and additional time might be required. These charges will be determined and contracted with Electrician. WORK NOT TO BE DONE: DRAW SCHEDULE 10%Down: 163y � 40%due upon contractors review&acceptance of project: 0A S 50%At Completion: <-,"Customer Initials erstand that one day installation is not guaranteed Total Investment: ' nderstand that hidden damage or deterioration,including plumbing waste and over 3.n flow,may be discovered and may incur additional charges to repair. 7 Initial Investment: I understand Jacuzzi recommends a fifty gallon hot water tank as a general rule.We have found that for our area a /i 3 forty gallon tank is sufficient for most users.We believe that this is because our tap waters much warmer than Balance Due: most of the country and therefore requires less time to warm.Your water heater is Z gallons. $ z I understand that the manufacturers'recommendations have been explained to me and Fairban s Construction makes no assurance to me of the viability of my existing hot water tank. Customer Initials Price Includes All Applicable Dis- counts. Customer Initialy Initialing,you agree that by your signature below,Fairbanks Construction,its No Other Offer Applies ' affiliates,or an thore ed representative may contact you by phone,fax,or e-mail about other services that may be of interest to you. You may always change your mind later:just let us know. Balance Due Upon Substantial Completion As Defined On Reverse Of NOTICE OF RIGHT TO CANCEL This Contract Item Vkh This is a home solicitation sale, if you do not want the goods or services, you may cancel this agreement by providing written notice via certified or registered mail. This notice must indicate that you do not want the goods or services and must be delivered or postmarked before midnight of the third business day after you sign this agreement. If you cancel this agreement, the seller may not keep all or part of any cash down payment. NOTICE TO OWNER A. Do not sign this home improvement contract in blank. R_ You are entitied to a conv of the contract at the time you uicin. Keel) it to oroteci vour ieclai riuhts. i4t A V-#1 e 1-S, Jacuzzi Walk-In Tub Job Name: Draw in fixtures and door locations Measure the following: Front Door width U Hallway width • Bath door width: 1 -2-'I'L2 3� �� Z 3 Wall Tile Against Door Frame [ ]Yes [ lo Ceiling height ! 1 Existing Tub: [ ]Castlron [ ]Steel [1- erglass 1 f Existing Tub height Tub length Tub width : 2- i Is Bathroom Floor in good condition? [ es ( ;No Step down into shower? [ ]Yes PJ11c Window Y1 -leight off of the floor : I� If Stairway what is width? Location of water shut off Vanity or toilet have to be removed? Is toilet on same side as exist tub faucet? Furniture need to be moved? Covered area for the installer to work? Hot Water Heater 40 Gallons or larger? [ es [ ]No Is homeowner aware of any existing plumbing issues? !(J-0 Total Number of Bathrgoms in Home Vpe�of Home : [-]Singlehrfamily [ ]Condo [ ]Mobile Other /1,st,,Znd rd Floor? Circle one 60/ ny customer special requests? - The following pictures taken? Doorway from both sides Front Door Tt r shower [ Hallway Plumbing wall Hot Water Heater Electrical Box Customers Electrical Box Brand name : SQ1"yC For Multi Unit Buildings Only: Property Manager Name: Phone#: -- Building Contact Person: Title: Phone #: Cell Phone#: What is Water Shut-Off Policy? Hours: Location: What is Elevator Policy?: Where can Installers Park: Where can Installers Set-up & Cut Panels?: ver 2.01.2014 JCI�UZZY® 5229 WALK-IN BATHTUB SERIES INSTALLATION AND OPERATION INSTRUCTIONS Jacuzzi® Luxury Bath 14525 Monte Vista Avenue Chino, CA 91710 1-800-288-4002 www.jacuzzi.com LX64000 03/2013 Jacuzzi, � 5229 Walk-In Bathtub Series Contents Contents...............................................................................................................................................................................................2 ProductInformation..............................................................................................................................................................................2 ImportantSafety Instructions................................................................................................................................................................3 Inspectionand Testing..........................................................................................................................................................................4 Framingand Support............................................................................................................................................................................5 Subfloor................................................................................................................................................................................................5 ElectricalConnections.........................................................................................................................................................................6 Priorto Installation................................................................................................................................................................................6 InstallationProcedures.........................................................................................................................................................................6 LevelingFeet Adjustment.....................................................................................................................................................................7 OptionalExtension Kit Installation.......................................................................................................................................................7 BackPanel Shelf Installation................................................................................................................................................................8 FinalSteps............................................................................................................................................................................................9 InstallationClean Up............................................................................................................................................................................9 DoorOperation.....................................................................................................................................................................................9 FaucetryInstallation.............................................................................................................................................................................9 5229 Reference Diagrams..................................................................................................................................................................10 GeneralOperation Information............................................................................................................................................................11 Controls...............................................................................................................................................................................................11 Operations..........................................................................................................................................................................................12 Controlling Whirlpool Direction and Flow............................................................................................................................................12 AromatherapyUse.......................................................................................................................:......................................................13 LightInstructions................................................................................................................................................................................13 RemovableSkirt Instructions..............................................................................................................................................................13 AdjustableSkirt Height Option............................................................................................................................................................14 Pr03Ozone Sanitation System..........................................................................................................................................................14 ShowerInformation............................................................................................................................................................................14 Heater.................................................................................................................................................................................................14 Cleaning......................................................................................................................................................... ................................... 14 Maintenance.......................................................................................................................................................................................15 TroubleshootingProcedures..............................................................................................................................................................15 AuthorizedService.............................................................................................................................................................................16 Warranty.............................................................................................................................................................................................17 Product • • NOTE Save these instructions for future use. Use the form below to record your model and serial number for future reference. Date Purchased Purchased From Installed By Serial Number Model Installer: Leave the manual for the homeowner. Homeowner: Read this manual and keep for future reference. •-------------------------------------------------• Dealer/Installer Information ------------------------------------------------- Page 2 Installation and Operation 5229 Walk-In Bathtub Series laeuzze. Important This is a professional grade product.A working knowledge of construction techniques, plumbing and electrical installation according to codes are required for proper installation and user satisfaction. We recommend that a licensed contractor perform the installation of all Jacuzzi Luxury Bath products. Our warranty does not cover improper installation related problems. READ AND FOLLOW ALL INSTRUCTIONS. SAVE THESE INSTRUCTIONS. Use this unit only for its intended use as described in this manual. Do not use attachments not recommended by the manufacturer. Never drop or insert any object into any opening. ® DANGER RISK OF ACCIDENTAL INJURY OR DROWNING! Do not permit children to use this unit unless they are closely supervised at all times. Do not use hydromassage bathtubs unless all suction guards are installed to prevent body and hair entrapment. Never operate the hydromassage bath if the suction cover is broken, damaged or missing. Do not operate this unit without the guard over the intake for the circulation pump (suction cover/strainer), IZL DANGER RISK OF SEVERE INJURY FROM ELECTRIC SHOCK OR DEATH FROM ELECTROCUTION! Product 1 must be connected only to a supply circuit that is protected by two 20 amp ground fault circuit interrupter (GFCI). Product 2 must be connected to a supply circuit that is protected by a 15 amp ground fault circuit interrupter(GFCI). Such a GFCI should be provided by the installer and should be tested on a routine basis. Follow the manufacturer's instructions when testing the GFCI. The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to the bathtub without the test button being pushed, a ground current is flowing, indicating a possibility of an electric shock. Do not use this hydromassage bathtub. Disconnect the hydromassage bathtub and have the problem corrected by a qualified service representative before using. ® DANGER RISK OF ELECTRIC SHOCK! Do not permit electrical appliances (such as a hair dryer, lamp, telephone, radio or television) within 60" (1524mrn) of this hydromassage bathtub. Connect only to a circuit protected by a ground fault circuit interrupter (GFCI). (For permanently connected units)A green colored terminal (or a wire connector) marked "G," "GR,""GROUND," or GROUNDING") is provided within the terminal compartment. To reduce the risk of electric shock, connect the terminal or connector to the grounding terminal of your electric service or supply panel with a conductor equivalent in size to the circuit conductors supplying the equipment. zh DANGER PROLONGED IMMERSION IN HOT WATER MAY INDUCE HYPERTHERMIA! Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6'F (37°C). The symptoms of hyperthermia include an increase in the internal temperature of the body, dizziness, lethargy, drowsiness and fainting. The effects of hyperthermia include: A. Failure to perceive heat. B. Failure to recognize the need to exit the bath. C. Unawareness of impending hazard. D. Fetal damage in pregnant women. E. Physical inability to exit the bath. F. Unconsciousness resulting in danger of drowning. ® DANGER This equipment is intended for indoor use only. Install the equipment in accordance with these instructions. Use supply wires that are suitable for 167'F (75'C), including the temperature rating of the supply conductors to be used. This unit should be electrically grounded and installed by a licensed contractor, electrician, and plumber. Building materials and wiring should be routed away from the motor/pump or blower or other heat producing components of this unit.A pressure wire connector is provided on the exterior of the motor/pump and heater to permit connection of an No. 8 AWG solid copper bonding conductor between this unit and all other electric equipment and exposed metal in the vicinity, as needed to comply with local requirements. lu, DANGER Risk of fetal injury. Pregnant or possibly pregnant women should consult a physician before using a hydromassage bathtub equipped with a heater. Installation and Operation v Page 3 1 Jaevzz'r, � 5229 Walk-In Bathtub Series Important • • - • ® CAUTION Keep body and hair a minimum of 6" (152mm) away from the suction fitting at all times when the hydromassage system is in operation. Hair longer than shoulder length should be secured close to the head. ® CAUTION Do not immerse the controls by overfilling the bath. ® CAUTION To avoid injury, use care when entering and exiting the hydromassage bathtub. ® CAUTION Do not use drugs or alcohol before or during the use of a hydromassage bathtub equipped with a heater. Possible drowning may occur. ® CAUTION Do not use a hydromassage bathtub equipped with a heater immediately following strenuous exercise. I® CAUTION Use this unit only for its intended use as described in this manual. Do not use attachments not recommended by the manufacturers. Do not tamper with user-operated controls or such devices. CAUTION Water temperature in excess of 104°F (40°C) may be injurious to your health. Check and adjust water temperature before use. SAVE THESE INSTRUCTIONS. The Company has obtained applicable code (standards) listings generally available on a national basis for products of this type. It is the responsibility of the installer/owner to determine specific local code compliance prior to installation of the product. Proper installation of the units is the responsibility of the installer. Jacuzzi Luxury Bath is not responsible for water damage due to improper installation. Product specifications are subject to change without notice. Inspection . Testing Visual Inspection 0 Remove the bathtub from the shipping carton. Be careful not to scratch the surface of the bathtub on exposed staples. Remove the staples or fold them into the carton. Retain the carton until satisfactory inspection of the product has been made. Do not lift the bathtub by the plumbing at any time; handle by the frame only. Inspect the shell and bathtub components. Should inspection reveal any damage or defect in the finish or visible damage to any components, do not install the bathtub. Damage or defect to the finish claimed after the bathtub is installed is excluded from the warranty. Jacuzzi Luxury Bath responsibility for shipping damage ceases upon delivery of the products in good order to the carrier. ® Refer any claims for damage to the carrier. For definitions of warranty coverage and limitations, refer to the published warranty information packed with the product or in the back of this manual. Bathtub Water and Operational All bathtub units are factory tested for proper operation and watertight connections prior to shipping. However, the unit must be retested by the installer prior to installation. Jacuzzi Luxury Bath is not responsible for any defect that could have been discovered, repaired, or avoided by following this inspection and testing procedure: 0 Place the bathtub on a level surface, near appropriate electrical supply,water supply, and water drainage.A driveway is a suitable choice. 0 Cover the drain and overflow hole with tape or a stopper and fill the bathtub to the bottom of the overflow hole. ® Allow bathtub to stand for 5 minutes. 0 Plug in motor/pump and turn unit on. Confirm that all features function as described in the Operation section of this manual. Do not install the bathtub if bathtub fails to operate as described. 0 Visually inspect all joints for leaks. Do not install the bathtub if leaks are detected. 0 Return bathtub to box or otherwise protect from damage until time of installation. Page 4 e �� �� Installation and Operation � •9Rcuzzi, 5229 Walk-In Bathtub Series Framing and Support READ ALL INSTALLATION INSTRUCTIONS COMPLETELY. IMPROPER INSTALLATION WILL VOID THE WARRANTY, IMPORTANT Make sure that walls and floors meet fire safety requirements of local building code and/or FHA/HUD Minimum Property Standards. Observe all governing codes and ordinances. 0 Proper installation is your responsibility. Have a qualified technician install this bath. Installation using a ground-fault circuit-interrupter(GFCI)is required. ® It is the installer's responsibility: •To contact a qualified electrical installer. •To assure that electrical installation is adequate and in conformance with National Electrical Code(NEC). •To assure that plumbing installation is adequate and in conformance with the Uniform Plumbing Code(UPC). A Technical Specification has been included with your bathtub.The Technical Specification will contain pertinent information regarding your Jacuzzi Luxury Bath product. Locate the Technical Specification at this time. NOTES Finished alcove must have correct interior dimensions, as shown in the rough-in diagrams in the Technical Specification, to properly install unit. For three wall alcove installations, use an integral molded three-sided tiling flanged bathtub. Jacuzzi Luxury Bath does not recommend utilizing bathtubs without an integral tiling flange in an alcove installation where a shower head would be installed above the unit and utilized as a shower. • In remodeling, if necessary, add studs at each end to provide a vertical nailing surface for the side nailing flanges of bath fixture product. • To avoid obstructions during installation make sure that supply lines, spout pipe and valve plumbing do not.project into alcove. • Bathtub requires a 4"x 14"(102mm x 356mm) recommended floor opening for the 1 ''/z"(38mm)drain, waste and overflow (DWO)kit. • Be sure floor opening location matches bathtub fixture drain location. 6229 Walk-In Bathtub • The unit must be supported from the bottom of (With optional filler extension kit) the bathtub and not solely from the bathtub rim. • Per UPC code, access must be provided to the pump/motor for your specific model (Figure 1). It is the responsibility of the installer, building contractor, or owner provide access for service.Jacuzzi Luxury Flange to p ry Extension Kit Bath is not responsible for any costs relating to obtaining access for repair.The owner shall bear such costs and, if appropriate, must seek recovery from the installer. Primary and secondary service access Removable locations are shown in the rough-in diagrams Access Panels contained in the Technical Specification. • Provide adequate ventilation for cooling and supply sufficient air for the pump/motor. Do not insulate around the equipment. Electrical Supply — Location • • • 0 Prepare the subfloor for the drain and ensure that the area is level. The drain/overflow of the bathtub extends below the bottom of the bathtub. Identify the drawing in the Technical Specification that corresponds with your bathtub. ® The bathtub must remain level in order for it to drain properly and must make contact with the leveling feet. 0 Floor must support seventy five pounds(75 lbs) per square foot load. Installation and Operation Page 5 QacuzD 5229 Walk-In Bathtub Series Electrical • • ® DANGER Risk of electric shock. Connect only to a circuit protected by a GFCI. ® CAUTION Electrical outlet must be mounted 4" (101mm) above the floor line and 12"max(305mm)inside from the edge of the bathtub, or in accordance with local building and electrical codes. Risk of component overheat. Do not use electric extension cord to power this unit. Operating the pump without enough water in the bathtub can cause permanent damage to the pump/motor. If the GFCI unit indicates a malfunction, per manufacturer's instructions, turn OFF power and do not attempt to use the bathtub until the source of the problem has been identified and corrected. NOTE When using electrical products, basic precautions should always be followed: • Always follow local building and electrical codes. Grounding is required. The unit should be installed and grounded by a qualified electrician. • Combination Models: Two separate dedicated 120VAC GFCI protected circuits are required to supply the pre-installed plug box. • Whirlpool/Pure Air Models:A dedicated 120VAC GFCI protected is required for pump/motor.A separate 120VAC GFCI protected circuit is required for the heater. Prior • Installation NOTE Before you begin your installation, please read the following: • Proper installation of the spout plumbing and compliance with local codes are the responsibility of the installer, Jacuzzi Luxury Bath does not warrant connections of water supply fittings and piping, fill systems, or drain/overflow systems. Nor is it responsible for darnage to the bathtub which may occur during installation. • Provide adequate ventilation around the equipment to ensure sufficient air flow and cooling. Do not block bloNer intake for any reason. Do not insulate the blower for any reason. Keep blower clear of all debris. • It may be necessary to level the 5229 Walk-In Bathtub. Use the leveling feet to adjust the levelness of the bathtub.The leveling feet operate in a similar manner as those for an appliance. • It is important to check the level prior to water testing. The unit must be level for water testing, as this helps with the door seal alignment. The adjustment nut allows you to adjust the height of the base.The locking nut allows you to lock in the desired height by tightening the nut. Under no circumstances will it be necessary to remove the leveling feet. • 50 Gallon water heater recommended. Consult with your installer/plumber for your household's specific requirements. Installation • - • ® Make sure framed-in alcove is of proper size per Jacuzzi Luxury Bath , dimensions, square, and plumb; check floor for levelness(Figure 3). Rough-in should be kept to a minimum until the unit is on the job site. Measurements may vary +0 or%"from original specifications. 0 Sufficient clearance must be provided for access to service connections (pump/motor, controls, heater plumbing and electrical hook ups). 37.5"H O (953 mm) - --- —Level Page 6 Installation and Operation • .��euzzi. 5229 Walk-In Bathtub Series Installation Procedures - . NCTES� grime Place the tub in the alcove with the front skirt firmly on the floor. The bathtub must be set level. To check, use a level on top of the ledges on both ends of tub and on top of dam (Figure 4). All adjustable feet must come in contact with the floor. All plumbing hardware (drain/waste overflow,water supply) must be installed prior to setting the bathtub in place. IMPORTANT Tile flange unit is required in a 3-wall alcove installation setting. Leveling Feet Adjustment NOTES The 5229 comes factory pre-leveled; however, it may be necessary to make adjustments to the leveling feet. The leveling feet operate in a similar manner as those for an appliance. It is important to check the level prior to water testing. Recommended Foot Height(Z) Standard Height: 1" For Reverse Plumbing Only:3" Reverse 0 The adjustment nut allows you to adjust the height of the Plumbing base. The locking nut allows you to lock in the desired Clearance height by tightening the nut. Threaded Leveling Leg ® If it is necessary to level the bathtub, start by leveling the Locking (1)center back wall leg, then move to the(4)corner legs, Nut(Top) then finish at the front center leg. Rail Adjustment © Check the bathtub for levelness. If the bathtub is level, Nut(Bottom) tighten the locking nut(Figure 5). Foot Q If the bathtub is not level, repeat the above steps. Z © For optional reverse plumbing installations only: Raise leveling feet to 3"as shown(Z) and install per local uniform - Rotate the leveling foot clockwise to lower the unit. plumbing code(UPC) requirements. - Rotate the leveling foot counter-clockwise to raise the unit. Optional • Installation Kit Unit Frame NOTES Pre-drilling flanges is recommended to avoid cracking of the acrylic unit. The front extension panel must be installed prior to installing the top extension panel. The illustration(Figure 6)is shown from the inside of / the unit for clarity purposes.All work shown may be Z / accessed from the top of the unit or through the access panel cutouts. Tie Wrap Angle (4 Locations) Bar Installation and Operation Page 7 Jaeuzzi. 5229 Walk-In Bathtub Series Me • • • • 117-T mmmm Clip . gum Front Panel Installation - O Use cable ties to attach the front extension panel to the frame of the unit. sa © Route the cable tie around the frame and through the <MP pre-drilled angle bar(Figure 6 page 7). Repeat in four(4) locations. a Insert the tip of the cable tie into the receiving end of the cable tie. DWO-''' O Once the tip has been inserted, pull the cable tie tight until the front extension panel is resting completely against the unit(Figure 6 page 7). ® Complete the fastening through vertical side flange, approximately 8"(205mm)on center(Figure 8). Tie Wrap Top View mom Side View Cable Tie Front Extension Panel Bathtub / — Angle Bar Silicone 1 Top Extension Wall Stud / Wall Stud Panel Silicone 4 Vertical Side Flange Mounting Screw Be htub Top Panel Installation - ® Route the cable tie around drain waste overflow(DWO)and through the plastic clip as illustrated (Figure 7). Place the top extension panel over the opening and fasten through the topside flanges at each stud 16"(405mrn)on center, working from both ends toward back center(Figure 9). ® Once complete, apply a continuous bead of silicone sealant around the entire seam between the top and front extension panels and the bathtub rim.Allow sealant to cure according to manufacturer's instructions. InstallationBack Panel Shelf 0 Fasten Angle to Studs as illustrated (Figure 10). Acrylic Wall • Fasten at every stud. (Cut to fit) ® Place Acrylic back shelf over Ledge as illustrated Mounting (Figure 10). Screw Acrylic Back Shelf Apply a bead of Silicone to all seams. (Cut to fit) Angle, Top Extension Silicone - Fastened Panel to Stud Double- Sided Tape Ledge Front Extension Panel Page 8 Installation and Operation Arm"Al rh 5229 Walk-In Bathtub Series StepsFinal ® Finishing of other trades should be done in conformance with applicable codes and generally accepted building practices. lam ® Inspect all fittings, plumbing, and control lines after inserting to insure the components are not damaged, disconnected, or contacting the finish surface substrate or support members. ® Note: Tubs are factoy pre-drilled for deck mounted tub fittings. Connect flex water supply lines to faucet, connect bathtub drains and plug power cords into GFCI outlets. O Turn on the power supply to the dedicated GFCI protected circuits and check system operation. ® Water test all fixtures; run pump and test operation. Apply a continuous bead of silicone sealant around the entire seam between the counter and the bathtub rim.Allow sealant to cure according 1� to manufacturer's instructions(Figure 11). \ Installation • r To avoid dulling and scratching the surface of the bathtub, never use abrasive cleaners. For most soiled surfaces, a mild liquid detergent and warm water is sufficient. The following is also recommended: • Remove spilled plaster with a wood or plastic edge. Spots left by plaster or grout can be removed if lightly rubbed with detergent on a damp cloth or sponge. Do not use metal scrapers, wire brushes or other metal tools, as they will damage the bathtub's surface. • Paint, tar, or other difficult stains can be removed with Fantastike or soapy water. • Minor scratches which do not penetrate the color finish can be removed by lightly sanding with 600-grit wet/dry sandpaper. You can restore the glossy finish to the acrylic surface of the bathtub with a special compound, Meguiar's#10 Mirror Glaze. If that is not available, use automotive rubbing compound followed by an application of automotive paste wax. • Major scratches and gouges which penetrate the acrylic surface will require refinishing. Call Jacuzzi Luxury Bath to find a service agent in your area. Door Operation NOTE ® The door opens to the inside of the bathtub. Use the inside door handle to engage the locking mechanism (Figure 12). ® Seal will prevent leakage. Provide a visual check and clean any debris from the seal area before filling the bathtub with water(see illustrations). CLOSE OPEN Seal i i Top View InstallationFaucetry Left-Hand(LH)Models Right-Hand(RH)Models OEM Install the faucetry and drain/waste overflow trim(DWO)at this time (please see installation instructions Hand Hand that came packaged with these Held Hot Cold Spout Spout HotCold_Held_ items). 6 6 6 p p 6 6 p i o � Installation and Operation __ Page 9 .I000ZZI- , 5229 Walk-In Bathtub Series 5229 Reference Diagrams Combination Models Light Blower Light Control Box PURE AIR o Q O ON/OFF Button Green GROUND ow U 11 (Green)GROUND ON/OFF Button (Wnite)NEUTRAL ®® ®® (While)NEUTRAL Black HOT (Black)HOT 0 0 WP Pump Heater WHIRLPOOL OTd Della Air Switch ®® r Heater .l ON/OFF Button "—"— Ozone Piggyback to Pump/Moor (Black)HOT (Black)HOT (White)NEUTRAL (White)NEUTRAL Pumool (Green)GROUND_]j (Green)GROUND 120VAC/20AMP 20VAC/20AMP GFCI Protected YFCI Protected MAIN CIRCUIT 0 o O NOTE CANADIAN MODELS ONLY: IG The components must be hardwired in the J-Boxes(supplied) that are located on the unit. ----------------------------------------------- ------- ------------- Whirlpool Models USA I ' Green GROUND USA (White)NEUTRAL (Black)HOT � _'•CANADA HEATER GFCIProtected I PUMP/MOTOR FON I OFF Button 120VAC/20AMP GFCI Protected USA (Green)GROUND USA (Whlle)NEUTRAL (Black)HOT Cal " _ -- I CANADA, NOTE Electrical J-Box purchased separately. Page 10 `� ^� Installation and Operation It \ CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD J ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 r1 ELECTRICAL PERMIT MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 15-ELEC-271 Job Type: ELECTRIC ONLY Description: 2 20amp gfi curcuits for jacauzzi Estimated Value: Issue Date: 2/5/2015 Expiration Date: 8/4/2015 PROPERTY ADDRESS: Address: 5809 FLEET LANDING BLVD RE Number: LOC ID-0000 PROPERTY OWNER: Name: NAVAL CONTINUING CARE Address: 1 FLEET LANDING BLVD 1 FLEET LANDING BLVD GENERAL CONTRACTOR INFORMATION: Name: BELLER ELECTRIC- STAN BELLER Address: 2720 SE 48Th ST Phone• - - FEES: State Elec DBPR Surcharge $2.00 State Elec DCA Surcharge $2.00 Lighting Outlets, Including Fixtures $1.20 Trade Permit Base Fee $55.00 Total Payments: $60.20 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. PLUMBING PERMIT APPLICATION Z CITY OF ATLANTIC BEACH 1� 800 Seminole Rd Atlantic Beach, FL 32233 Ph (904) 247-5826 Fax (904) 247-5845 JOB ADDRESS: 0� t abj�IJ'fCj B1 Vu T6"77NJ C&I" ft 302.33 PERMIT # NEW Ogii&ACEMENT NSTALLATION: Project Values am TYPE OF FIXTURE QT i? YPR-0,,'�F/XTURE QTY Bathtub 'ptic,lank& Pit Clothes Washer Showgrkl Dishwasher FEB 0 3 ShoW,00an Drinking Fountain Slop Si Floor DrainThree Cmpartment Sink Floor Sink ,s y let Hose Bibs Urinal / Kitchen Sink Vacuum Breakers 1 Laundry Tray Water Connected Appliances Lavatory Water Heater Other Fixtures Water Treating System RE-PIPE: TYPE OF FIXTURE Q OF FIXTURE QTY V ,ti Bathtub p Tank&Pit Clothes Washer o , Dishwasher ho an Drinking Fountain Slop S Floor Drain Three Compartment Sink Floor Sink Toilet Hose Bibs Urinal Kitchen Sink Vacuum Breakers Laundry Tray Water Connected Appliances Lavatory Water Heater Other Fixtures Water Treating System MISCELLANEOUS: ❑ Sewer Replacement ❑ Back Flow Preventer ❑ Grease Interceptor (Trap) gallons(Requires 3 sets of plans) ❑ Lawn Sprinkler System-Number of Heads ❑ Well ** SJRWD Well Cop�l-e�ion 01o m., m leted form to be sub witted to tW BVdin Department for final inspection." OVe 01 � �' � w�� U r� /Other I 1 r1 `� lr V- I.t,a, KS Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or not. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name Y l(! Pr *akiqQ MZ f a c-'i Me, Phone Number 70V-X ti 44" `�Iaq Plumbing Company V v v S g6iY (_t_C Office Phone o'h'o �'��ltFax Co. Address: 499 30 tj W �Q � � City State r Zip License Holder(Print): ro5:1- sStat erti ation/Registration# Chi/'�o�(�y7 Notarized Signature of License Holder .�aYP�Bi, RICFInRDLRAGLE Sworn an subscribed before me this_ da of S+iJ 205 MY COMMISSION N EE 665476 * EXPIRM J0 Ny 21,2017 Signature of Notary Public s� o� 1hN Bud6e► oi>MJ �Tf OF FtG 1720 NW 4th Avenue FAIRBANKSSuite 100 ��t rvALK-IN TUB SPEC Ocala,FL 34475 coNsRucTio � Phone(352)732-8600 Toll Free(800)743-8601 Job# 1,5010 Fax(352)732-0069 a/)oisiongJFairhank. Connncungand Remodeling Inc. FairbanksConstruction99.coom( C, #CRC050304 -it / HC0002524 Customer W �1� YWlet S �8O / CXR �-eAIti t A/k/j RT� L Date: NOTE: Items must be marked to be included WORK TO BE DONE Jacuzzi Mo I DFS Walk-in Tub � Air Jets: Lifetime Warranty: Color: Mo ❑Almond Ozone Generator, Door Frame R&R: �j * Door: LM Left ❑Right Aromatherapy: L�,,,/// Wall System Color: Chrome Faucet: Chromotherapy: Wall System Style: 1A_ Hand Held Spray: Tub Extension: Extra Grab Bar: In-Line Heater: Basic Electrical: Hydro Jets: Delivery: ADDITIONAL NOTES: s �L ... .. ... ... ... ... ... ... ... ... ... ... ... ... ... .. ... ... ... ... . . ... ... ... ... ... ... ... ... ... ... ... . . . �Q-!M+►�-. .I ca.S`��!,-�. . ?�� .f a!�,9 ... ..`... ... ... ... ... ... ... ... ... ... ... ... . .► ... .. tf i ... .. ... ... ... ... ... ... ... .. . . ... ... ... .. ... ... ... ...L... ... ... ... ... ... ... ... ... ... ... ... . ... ... ... .. 0. .MeN►.. �.�. . .. x,s /. ... ... .. .. ... ... ... . ... ... ... ... ... ... ... . .r ... ... .. ... ... ..�� .. ,Af.Y .. ... ... ... ... ... ... ... ... ... ... ... ... .. ... ... ... .. ... .. ... ... ... ... .�... . . - ... ... .. ::. .. ... ... ::: x.:5� :: :5: ; :: ::: :: ... ... ... .. . . � ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... .. .. ... ... ... ... � .. .111.Cl .�(.4...S.�.eil v . ./.�l!v( . ..:1 .. .Y�.!`!'"... ... ... ... ... ... ... ... ... ... ... .. D ... .. .�.. .�. ... .. ... ... ... ... ... ... ... ... .p ... . ... . . . ... ... ... ... ... ... ... ... ... ... ... ... ... ... .. . �. ..1.�. .. . .. . ..��� . ... ... ... ... ... ... ... ... .. 77, .. ... .. ... ... ... . . ... ... .:. . .. .. ... ... ... ...vel. e�J.. �� . ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... .. `'�. ... ... ... ... ... ... ... . ... ... ... .. ... ... ... ... ... ... ... ... ... ... ... ... ... .. . .W. � ... .. !rl!..!-�. ..a. ... . ... ... ... ... ... ... ... ... ... ... ... ... ... ... .. ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... CUSTOMER SIGNATURE 0 7.K__ ViMQ11DATE Rev.6/10/13 1720 N.W.4th Avenue Suite 100 FAIRRANKS • Ocala,FL 34475 ,.0QCUZZIC� Phone(352)732-8600 Toll Free(800)743-8601 CONSTRUCT 10 N Walk In Tub Contract Fax(352)732-0069 www.FairbanksConstruction.com A Uivlsiun g174nrlwnkc(bnlradinx and Rernralrling,lnc. � 0 D 1J, #CRC05Q304 - 11CO002524 Job# 15- 010 / Sold To: -�^ + '1Zc w1w;,c� A A rhi f t S��r �Phone:�5�p/� 2cf�" y-�'Lf.3 Date:i� Physical Address : -5-8(09 t'l'u 7t te2�1ha 13)vel City: C1T�C T t D'�i: ,_ State: Zip: S,2 93 3� Mailing Address : y`-'�- City: State: Zip: (if diff nt fr m physical address,otherwise'same') Email: 4 Approx Start Date: 7-9 weeks Approx Finish Date: 1-3 days a-,,>-i (from permit obtained date,if required) (from start date) The undersigned Seller hereby sells and the undersigned BUYERS hereby purchases. If one or more of them,jointly and severally, the below described goods and services for the price and upon the terms and conditions set forth herein. WORK TO BE DONE NOTE: ITEMS NOT MARKED ON CONTRACT ARE NOT INCLUDED Jacuzzi ra,Combination Walk-In Tub Includes: 10 Hydro Therapy Jets, 16 Air jets,Inline Heater,Ozonator, Aromtherapy,Chromtherapy,Chrome Faucet&hand-held sprayer Model: 0-6 eluxe 5229 ❑ Comfort 3732 ❑Grand 5433 Jacuzzi a Classic Walk-in Tub Includes:6 Hydro Therapy jets,Inline Heater,Chrome faucet&hand-held sprayer. Model: ❑ Classic 5229 ❑Classic Grand 5433 Options: e : Doo Swing: Wall System: Ele rical: Life ' e Warranty: ie Do ❑Style ©'basic Electric 21included ❑6wond ❑Right ❑Color, ❑Electric Sub Panel Door Frame: ub Trim Extension ❑Additional Grab bars# ❑Remove and reinstall ELECTRICAL Fairbanks Construction contracts electrical work to licensed Electricians. Install includes basic electrical circuits ONLY to 75 feet from existing panel and ONLY with spare circuit(s)in panel. If no spares or distance is farther or other work is needed,additional charges will apply and additional time might be required. These charges will be determined and contracted with Electrician. WORK NOT TO BE DONE: DRAW SCHEDULE 10%Down: � 40%due upon contractors review&acceptance of project: Ga. 1'Cu�S 50%At Completion: stomer Initials Znderstand 'stand that one day installation is not guaranteed Total Investment: that hidden damage or deterioration,including plumbing waste and over t�� �.ay be discovered and may incur additional charges to repair. Initial Investment: I understand Jacuzzi recommends a fifty gallon hot water tank as a general rule.We have found that for our area a $ 46 .53 forty gallon tank is sufficient for most users.We believe that this is because our tap waters much warmer than Balance Due: most of the country and therefore requires less time to warm.Your water heater is gallons. j I understand that the manufacturers'recommendations have been explained to me and Fairban s Construction t makes no assurance to me of the viability of my existing hot water tank. Customer Initials Price Includes All Applicable Dis- counts. ? Customer Initialy Initialing,you agree that by your signature below,Fairbanks Construction,its No Other Offer Applies affiliates,or an thorized representative may contact you by phone,fax,or e-mail about other services that may be of interest to you. You may always change your mind later:just let us know, Balance Due Upon Substantial Completion As Defined On Reverse Of NOTICE OF RIGHT TO CANCEL This Contract Item Vkh This is a home solicitation sale, if you do not want the goods or services, you may cancel this agreement by providing written notice via certified or registered mail. This notice must indicate that you do not want the goods or services and must be delivered or postmarked before midnight of the third business day after you sign this agreement. If you cancel this agreement, the seller may not keep all or part of any cash down payment. NOTICE TO OWNER A. Do not sign this home improvement contract in blank. 13_ Ynii are entitlerl to a cnnv nT the cnntract at the time you :;Ian. Keel] ii to rn7rotect vour ieaai ria ts. Jacuzzi Walk-In Tub Job Name: Draw in fixtures and door locations Measure the following: Front Door width Hallway width : �� i D j Bath door width: 1_�2�/Z 2 3 Y Z 3 Wall Tile Against Door Frame [ ]Yes [-1114'o l Ceiling height : 1 Existing Tub: [Tub: [ ]Castlron [ ]Steel [9f erglass Existing Tub height_ Tub length Tub width Is Bathroom Floor in good condition? [^fiYes ( ]No Step down into shower? [ ]Yes (�o : - Window Y10 eight off of the floor If Stairway what is width? Location of water shut off Vanity or toilet have to be removed? Is toilet on same side as exist tub faucet? : N-e i Furniture need to be moved? : >v`�' � ,{V Covered area for the installer to work? Hot Water Heater 40 Gallons or larger? [ es [ ]No Is homeowner aware of any existing plumbing issues? /U-0 Total Number of Bathrr ms in Home : r 1T p of Home : [� iS ngle family [ ]Condo [ ]Mobile Other st nd 3rd Floor? Circle one ny customer special requests? (SLC The following pictures taken? / Doorway from both sides [ Front Door [� T��r shower LJ Hallway Plumbing wall Hot Water Heater Electrical Box Customers l :� Electrical Box Brand name : 54wyE' For Multi Unit Buildings Only: Property Manager Name: Phone#: -- Building Contact Person: Title: Phone #: Cell Phone#: What is Water Shut-Off Policy? Hours: Location: What is Elevator Policy?: Where can Installers Park: Where can Installers Set-up & Cut Panels?: ver 2.01.2014 JaeuZZY, 5229 WALK-IN BATHTUB SERIES INSTALLATION AND OPERATION INSTRUCTIONS Jacuzzi®Luxury Bath 14525 Monte Vista Avenue Chino, CA 91710 1-800-288-4002 www.jacuzzi.com LX64000 0312013 1 Jacuzzi, dam ft- h 5229 Walk-In Bathtub Series Contents Contents...............................................................................................................................................................................................2 ProductInformation...........................................................................................................................................:..................................2 ImportantSafety Instructions................................................................................................................................................................3 Inspectionand Testing..........................................................................................................................................................................4 Framingand Support............................................................................................................................................................................5 Subfloor................................................................................................................................................................................................5 ElectricalConnections.........................................................................................................................................................................6 Priorto Installation................................................................................................................................................................................6 InstallationProcedures.........................................................................................................................................................................6 LevelingFeet Adjustment.....................................................................................................................................................................7 OptionalExtension Kit Installation.......................................................................................................................................................7 BackPanel Shelf Installation................................................................................................................................................................8 FinalSteps............................................................................................................................................................................................9 InstallationClean Up............................................................................................................................................................................9 DoorOperation.....................................................................................................................................................................................9 FaucetryInstallation.............................................................................................................................................................................9 5229 Reference Diagrams..................................................................................................................................................................10 GeneralOperation Information............................................................................................................................................................11 Controls...............................................................................................................................................................................................11 Operations..........................................................................................................................................................................................12 ControllingWhirlpool Direction and Flow............................................................................................................................................12 AromatherapyUse....................................................................................................................... ......................................................13 LightInstructions................................................................................................................................................................................13 RemovableSkirt Instructions..............................................................................................................................................................13 AdjustableSkirt Height Option............................................................................................................................................................14 Pr03Ozone Sanitation System..........................................................................................................................................................14 ShowerInformation............................................................................................................................................................................14 Heater.................................................................................................................................................................................................14 Cleaning......................................................................................................................................................... ................................... 14 Maintenance............................................................................................................................................:..........................................15 TroubleshootingProcedures..............................................................................................................................................................15 AuthorizedService.............................................................................................................................................................................16 Warranty.............................................................................................................................................................................................17 Product • • NOTE Save these instructions for future use. Use the form below to record your model and serial number for future reference. Date Purchased Purchased From Installed By Serial Number Model Installer: Leave the manual for the homeowner. Homeowner: Read this manual and keep for future reference. -------------------------------------------------• Dealer/Installer Information ' -------------------------------------------------- Page 2 Installation and Operation 5229 Walk-In Bathtub Series .1aeuZ7.A, Important • This is a professional grade product.A working knowledge of construction techniques, plumbing and electrical installation according to codes are required for proper installation and user satisfaction. We recommend that a licensed contractor perform the installation of all Jacuzzi Luxury Bath products. Our warranty does not cover improper installation related problems. READ AND FOLLOW ALL INSTRUCTIONS. SAVE THESE INSTRUCTIONS. Use this unit only for its intended use as described in this manual. Do not use attachments not recommended by the manufacturer. Never drop or insert any object into any opening. ® DANGER RISK OF ACCIDENTAL INJURY OR DROWNING! Do not permit children to use this unit unless they are closely supervised at all times. Do not use hydromassage bathtubs unless all suction guards are installed to prevent body and hair entrapment. Never operate the hydromassage bath if the suction cover is broken, damaged or missing. Do not operate this unit without the guard over the intake for the circulation pump (suction cover/strainer). ® DANGER FRISK OF SEVERE INJURY ELECTRIC ROM ELECT- OCUTION.► PrROM must be connectednSHOCK ORDEATH connected only to a supply circuit that is protected by two 20 arnp ground fault circuit interrupter(GFCI). Product 2 must be connected to a supply circuit that is protected by a 15 amp ground fault circuit interrupter(GFCI). Such a GFCI should be provided by the installer and should be tested on a routine basis. Follow the manufacturer's instructions when testing the GFCI. The GFCI should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to the bathtub without the test button being pushed, a ground current is flowing, indicating a possibility of an electric shock, Do not use this hydromassage bathtub. Disconnect the hydromassage bathtub and have the problem corrected by a qualified service representative before using. J® DANGER RISK OF ELECTRIC SHOCK! Do not permit electrical appliances (such as a hair dryer, lamp, telephone, radio or television) within 60" (1524mrn) of this hydromassage bathtub. Connect only to a circuit protected by a ground fault circuit interrupter (GFCI). (For permanently connected units)A green colored terminal (or a wire connector) marked °G," "GR," "GROUND," or GROUNDING") is provided within the terminal compartment. To reduce the risk of electric shock, connect the terminal or connector to the grounding terminal of your electric service or supply panel with a conductor equivalent in size to the circuit conductors supplying the equipment. DANGER PROLONGED IMMERSION IN HOT WATER MAY INDUCE HYPERTHERMIA! Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6'F (37°C). The symptoms of hyperthermia include an increase in the internal temperature of the body, dizziness, lethargy, drowsiness and fainting. The effects of hyperthermia include: A. Failure to perceive heat. B. Failure to recognize the need to exit the bath. C. Unawareness of impending hazard. D. Fetal damage in pregnant women. E. Physical inability to exit the bath. F. Unconsciousness resulting in danger of drowning. ® DANGER This equipment is intended for indoor use only. Install the equipment in accordance with these instructions. Use supply wires that are suitable for 167'F (75'C), including the temperature rating of the supply conductors to be used. This unit should be electrically grounded and installed by a licensed contractor, electrician, and plumber. Building materials and wiring should be routed away from the motor/pump or blower or other heat producing components of this unit.A pressure wire connector is provided on the exterior of the motor/pump and heater to permit connection of an No. 8 AWG solid copper bonding conductor between this unit and all other electric equipment and exposed metal in the vicinity, as needed to comply with local requirements. DANGER Risk of fetal injury. Pregnant or possibly pregnant women should consult a physician before using a hydromassage bathtub equipped with a heater. Installation and Operation Page 3 .laeuzzi, � 5229 Walk-In Bathtub Series Important • • • • ® CAUTION Keep body and hair a minimum of 6"(152mm) away from the suction fitting at all times when the hydromassage system is in operation. Hair longer than shoulder length should be secured close to the head. CAUTION Do not immerse the controls by overfilling the bath. �® CAUTION To avoid injury, use care when entering and exiting the hydromassage bathtub. ® CAUTION Do not use drugs or alcohol before or during the use of a hydromassage bathtub equipped with a heater. Possible drowning may occur. ® CAUTION Do not use a hydromassage bathtub equipped with a heater immediately following strenuous exercise. CAUTION Use this unit only for its intended use as described in this manual. Do not use attachments not recommended by the manufacturers. Do not tamper with user-operated controls or such devices. CAUTION Water temperature in excess of 104°F (40°C) may be injurious to your health. Check and adjust water temperature before use. SAVE THESE INSTRUCTIONS. The Company has obtained applicable code (standards) listings generally available on a national basis for products of this type. It is the responsibility of the installer/owner to determine specific local code compliance prior to installation of the product. Proper installation of the units is the responsibility of the installer. Jacuzzi Luxury Bath is not responsible for water damage due to improper installation. Product specifications are subject to change without notice. Ins. - • • InspectionVisual 0 Remove the bathtub from the shipping carton. Be careful not to scratch the surface of the bathtub on exposed staples. Remove the staples or fold them into the carton. Retain the carton until satisfactory inspection of the product has been made. Do not lift the bathtub by the plumbing at any time; handle by the frame only. ® Inspect the shell and bathtub components. Should inspection reveal any damage or defect in the finish or visible damage to any components,do not install the bathtub. Damage or defect to the finish claimed after the bathtub is installed is excluded from the warranty. Jacuzzi Luxury Bath responsibility for shipping damage ceases upon delivery of the products in good order to the carrier. Refer any claims for damage to the carrier. For definitions of warranty coverage and limitations, refer to the published warranty information packed with the product or in the back of this manual. Bathtub Water and Operat ional All bathtub units are factory tested for proper operation and watertight connections prior to shipping. However, the unit must be retested by the installer prior to installation. Jacuzzi Luxury Bath is not responsible for any defect that could have been discovered, repaired, or avoided by following this inspection and testing procedure: 0 Place the bathtub on a level surface, near appropriate electrical supply,water supply, and water drainage.A driveway is a suitable choice. ® Cover the drain and overflow hole with tape or a stopper and fill the bathtub to the bottom of the overflow hole. ® Allow bathtub to stand for 5 minutes. 0 Plug in motor/pump and turn unit on. Confirm that all features function as described in the Operation section of this manual. Do not install the bathtub if bathtub fails to operate as described. 0 Visually inspect all joints for leaks. Do not install the bathtub if leaks are detected. Q Return bathtub to box or otherwise protect from damage until time of installation. Paye 4 e �� � � �^�� Installation and Operation � � e 5229 Walk-In Bathtub Series l�(ICUz71, Framing and Support READ ALL INSTALLATION INSTRUCTIONS COMPLETELY. IMPROPER INSTALLATION WILL VOID THE WARRANTY, IMPORTANT Make sure that walls and floors meet fire safety requirements of local building code and/or FHA/HUD Minimum Property Standards. Observe all governing codes and ordinances. ® Proper installation is your responsibility. Have a qualified technician install this bath. Installation using a ground-fault circuit-interrupter(GFCI) is required. ® It is the installer's responsibility: •To contact a qualified electrical installer. •To assure that electrical installation is adequate and in conformance with National Electrical Code(NEC). •To assure that plumbing installation is adequate and in conformance with the Uniform Plumbing Code(UPC). A Technical Specification has been included with your bathtub. The Technical Specification will contain pertinent information regarding your Jacuzzi Luxury Bath product. Locate the Technical Specification at this time. NOTES Finished alcove must have correct interior dimensions, as shown in the rough-in diagrams in the Technical Specification, to properly install unit. For three wall alcove installations, use an integral molded three-sided tiling flanged bathtub. Jacuzzi Luxury Bath does not recommend utilizing bathtubs without an integral tiling flange in an alcove installation where a shower head would be installed above the unit and utilized as a shower. • In remodeling, if necessary, add studs at each end to provide a vertical nailing surface for the side nailing flanges of bath fixture product. • To avoid obstructions during installation make sure that supply lines, spout pipe and valve plumbing do not prcject into alcove. • Bathtub requires a 4"x 14"(102mm x 356mm) recommended floor opening for the 1 %."(38mm)drain,waste and overflow (DWO)kit. • Be sure floor opening location matches bathtub fixture drain location. 6229 Walk-In Bathtub • The unit must be supported from the bottom of (with optional filler extension kit) the bathtub and not solely from the bathtub rim. • Per UPC code, access must be provided to the pump/motor for your specific model (Figure 1). It is the responsibility of the installer, building contractor, or owner torovide access for service.Jacuzzi Luxury Flange p ry Bath is not responsible for any costs relating Extension Kit to obtaining access for repair.The owner shall bear such costs and, if appropriate, must seek recovery from the installer. Primary and secondary service access Removable locations are shown in the rough-in diagrams Access Panels contained in the Technical Specification. • Provide adequate ventilation for cooling and supply sufficient air for the pump/motor. Do not insulate around the equipment. Electrical Supply Location •floor 4 Prepare the subfloor for the drain and ensure that the area is level. The drain/overflow of the bathtub extends below the bottom of the bathtub. Identify the drawing in the Technical Specification that corresponds with your bathtub. ® The bathtub must remain level in order for it to drain properly and must make contact with the leveling feet. ,® Floor must support seventy five pounds(75 lbs)per square foot load. Installation and Operation Page 5 .lacuzzi, Aloft� 5229 Walk-In Bathtub Series Electrical Connections FZE DANGER gums Risk of electric shock. Connect only to a circuit protected by a GFCI. IzE CAUTION Electrical outlet must be mounted 4" (101mm) above the floor line and 12"max(305mm)inside from the edge of the bathtub, or in accordance with local building and electrical codes. Risk of component overheat. Do not use electric extension cord to Power this unit. Operating the pump without enough water in the bathtub can cause permanent damage to the pump/motor. If the GFCI unit indicates a malfunction, per manufacturer's instructions, turn OFF power and do not attempt to use the bathtub until the source of the problem has been identified and corrected, I NOTES When using electrical products, basic precautions should always be followed: • Always follow local building and electrical codes. Grounding is required.The unit should be installed and grounded by a qualified electrician. • Combination Models: Two separate dedicated 120VAC GFCI protected circuits are required to supply the pre-installed plug box. • Whirlpool/Pure Air Models:A dedicated 120VAC GFCI protected is required for pump/motor.A separate 120VAC GFCI proterted circuit is required for the heater. Prior • Installation NOTE Before you begin your installation, please read the following: • Proper installation of the spout plumbing and compliance with local codes are the responsibility of the installer. Jacuzzi Luxury Bath does not warrant connections of water supply fittings and piping, fill systems, or drain/overflow systems. Nor is it responsible for damage to the bathtub which may occur during installation. • Provide adequate ventilation around the equipment to ensure sufficient air flow and cooling. Do not block blower intake for any reason. Do not insulate the blower for any reason. Keep blower clear of all debris. • It may be necessary to level the 5229 Walk-In Bathtub. Use the leveling feet to adjust the levelness of the bathtub. The leveling feet operate in a similar manner as those for an appliance. • It is important to check the level prior to water testing. The unit must be level for water testing,as this helps with the door seal alignment. The adjustment nut allows you to adjust the height of the base. The locking nut allows you to lock in the desired height by tightening the nut. Under no circumstances will it be necessary to remove the leveling feet. • 50 Gallon water heater recommended. Consult with your installer/plumber for your household's specific requirements. Installation • • . Make sure framed-in alcove is of proper size per Jacuzzi Luxury Bath dimensions, square, and plumb; check floor for levelness(Figure 3). Rough-in should be kept to a minimum until the unit is on the job site. Measurements may vary +0 or%"from original specifications. 4 Sufficient clearance must be provided for access to service connections (pump/motor, controls, heater plumbing and electrical hook ups). 37.5"H O (953 mm) --- — Level Page 6 Installation and Operation .�fICUZZI, 5229 Walk-In Bathtub Series Installation - . - . NOTES Place the tub in the alcove with the front skirt firmly on the floor. The bathtub must be set level. To check, use a level on top of the ledges on both ends of tub and on top of dam(Figure 4). All adjustable feet must come in contact with the floor. All plumbing hardware(drain/waste overflow,water supply)must be installed prior to setting the bathtub in place. IMPORTANT Tile flange unit is required in a 3-wall alcove installation setting. Leveling Feet Adjustment NOTES The 5229 comes factory pre-leveled; however, it may be necessary to make adjustments to the leveling feet.The leveling I ' feet operate in a similar manner as those for an appliance. Recommended Foot Height(Z) It is important to check the level prior to water testing. Standard Height: 1" For Reverse Plumbing Only:3" Reverse 0 The adjustment nut allows you to adjust the height of the Plumbing base. The locking nut allows you to lock in the desired Clearance height by tightening the nut. Threaded Leveling Leg ® if it is necessary to level the bathtub, start by leveling the Locking (1)center back wall leg, then move to the(4)corner legs, Nut(Top) then finish at the front center leg. LE Rail Adjustment ® Check the bathtub for levelness. If the bathtub is level, Nut(Bottom) tighten the locking nut(Figure 5). Foot 0 If the bathtub is not level, repeat the above steps. © For optional reverse plumbing installations only: Raise leveling feet to 3"as shown(Z)and install per local uniform - Rotate the leveling foot clockwise to lower the unit. plumbing code(UPC)requirements. - Rotate the leveling foot counter-clockwise to raise the unit. Optional • Kit InstallationUnit Frame NOTES Pre-drilling flanges is recommended to avoid cracking of the acrylic unit.The front extension panel must be installed prior to installing the top extension panel. The illustration(Figure 6)is shown from the inside of / the unit for clarity purposes.All work shown may be accessed from the top of the unit or through the access — panel cutouts. I _ Tie Wrap Angle (4 Locations) Bar Installation and Operation Page 7 5229 Walk-In Bathtub Series Front Panel Installation - ® Use cable ties to attach the front extension panel to the frame of the unit. © Route the cable tie around the frame and through the pre-drilled angle bar(Figure 6 page 7). Repeat in four(4) locations. ® Insert the tip of the cable tie into the receiving end of the cable tie. DWO--' 0 Once the tip has been inserted, pull the cable tie tight until the front extension panel is resting completely against the unit(Figure 6 page 7). 0 Complete the fastening through vertical side flange, approximately 8"(205mm)on center(Figure 8). Tie Wrap Top View Side View Cable Tie Front Extension Panel ED Bathtub / Angle Bar Silicone / ( Top Extension Wall Stud Wall Stud Panel Silicone �—Vertical Side Flange Mounting Screw Ba htub Top Panel Installation - 0 Route the cable tie around drain waste overflow(DWO)and through the plastic clip as illustrated (Figure 7). 0 Place the top extension panel over the opening and fasten through the topside flanges at each stud 16" (405mrn)on center, working from both ends toward back center(Figure 9). 0 Once complete, apply a continuous bead of silicone sealant around the entire seam between the top and front extension panels and the bathtub rim.Allow sealant to cure according to manufacturer's instructions. InstallationBack Panel Shelf 0 Fasten Angle to Studs as illustrated (Figure 10). Acrylic Wall Fasten at every stud. (Cut to fit) 0 Place Acrylic back shelf over Ledge as illustrated Mounting Screw (Figure 10). Acrylic Back Shelf 0 Apply a bead of Silicone to all seams. (Cut to fit) Angle, Top Extension Silicone - - Fastened Panel to Stud Double- Sided Tape -- - -Ledge Front Extension Panel Page 8 Installation and Operation Jacuzzi. 5229 Walk-In Bathtub Series - • ® -Finishing of other trades should be done"T conformance with applicable codes and generally accepted building practices. ® Inspect all fittings, plumbing, and control lines after inserting to insure the components are not damaged,disconnected, or contacting the finish surface substrate or support members. ® Note: Tubs are factoy pre-drilled for deck mounted tub fittings. Connect flex water supply lines to faucet, connect bathtub drains and plug power cords into GFCI outlets. 0 Turn on the power supply to the dedicated GFCI protected circuits and check system operation. ® Water test all fixtures, run pump and test operation. 0 Apply a continuous bead of silicone sealant around the entire seam between the counter and the bathtub rim.Allow sealant to cure according to manufacturer's instructions(Figure 11). Installation Clean • To avoid dulling and scratching the surface of the bathtub, never use abrasive cleaners. For most soiled surfaces, a mild liquid detergent and warm water is sufficient. The following is also recommended; • Remove spilled plaster with a wood or plastic edge. Spots left by plaster or grout can be removed if lightly rubbed with detergent on a damp cloth or sponge. Do not use metal scrapers,wire brushes or other metal tools, as they will damage the bathtub's surface. • Paint, tar, or other difficult stains can be removed with Fantastik®or soapy water. • Minor scratches which do not penetrate the color finish can be removed by lightly sanding with 600-grit wet/dry sandpaper. You can restore the glossy finish to the acrylic surface of the bathtub with a special compound, Meguiar's#10 Mirror Glaze. If that is not available, use automotive rubbing compound followed by an application of automotive paste wax. • Major scratches and gouges which penetrate the acrylic surface will require refinishing. Call Jacuzzi Luxury Bath to find service agent in your area. Door • •eration NOTE ® The door opens to the inside of the bathtub. Use the inside door handle to engage the locking mechanism(Figure 12). ® Seal will prevent leakage. Provide a visual check and clean any debris from the seal area before filling the bathtub with water(see illustrations). CLOSE OPEN _- - Seal i i Top View InstallationFaucetry Left-Hand(LH)Models Right-Hand(R4de arm Install the faucetry and drain/waste overflow trim (DWO) at this time (please see installation instructions Hand that came packaged with these Held Hot Cold Spout Spout Hot Citems). 8 8 0 0 0 �"J Installation and Operation Page 9 .1(ICUZZI. � 5229 Walk-In Bathtub Series 5229 Reference Diagrams Combination Models Llghl i Blower Light Control _ Box 0 PURE AIR O LIGHT O ON I OFF Button Green GROUNDower (Green)GROUND ON I OFF Button (White)NEUTRAL ®® ®® (While)NEUTRAL Bleck HOT ®� ®® (Black)HOT ® WP Pump Heater WHIRLPOOL O Tri Della Air Switch ter Hea ON/OFF Button Piggyback to Ozone Pump/Mctor (Bleck)HOT (Bieck)HOT (White)NEUTRAL (While)NEUrRAL Whirlpool (Green)GROUND (Green)GROUND Pump III 120VAC/20AMP 120VAC/20AMP GFCI Protected GFCI Protected MAIN CIRCUIT tI NOTE CANADIAN MODELS ONLY: The components must be hardwired in the J-Boxes (supplied)that are located on the unit. --------------- ------------------------- -- ------ -------------- Whirlpool Models IOU IGreen GROUND USA USA (White)NEUTRAL (Black)HOT CANADA HEATER /20AMP GFCI PrI PUMP/MOTOR GFCI Protected ON I OFF Button 120VAC/20AMP GFCI Protected USA,"" USA -'-. (Green)GROUND ® ; (While)NEUTRAL (Black)HOT CANADA,,- NOTE Electrical J-Box purchased separately. Page 10 Installation and Operation