22 Stanley Road 15-DRTV-1003 (was 1795 Mayport)20 .0 10 20 SITE AREA SUMMARY: TOTAL SITE: 18,018 SF SCALE IN FEET EXISTING PERCENT IMPERVIOUS: 0% x z U PROPOSED IMPERVIOUS AREA: co BUILDINGS: 3,611 SF PAVEMENTS AND SIDEWALKS: 1,330 SF TOTAL: 4,941 SF PROPOSED PERCENT IMPERVIOUS: 4,941 SF / 18,018 SF = 27.4% FOUND IRON PIPE Cy z (NO CAP) O RETENTION BASIN CALCULATIONS: U'/ E - VOLUME REQUIRED: STANLEY ROAD V - CA(R/12) STANDLEY ROAD BY PLAT ' o = POST- (0.42)(18,018 SF)(9.3°/12) = 5,893 CF' 30' RIGHT-OF-WAY BY PLAT �� ryh� 3 *� BENCHMARK � VPRE - CA(R/12) SANITARY 'AA IHOLE +^ _` — =y—�+ - - _ 8^ + BEN CHMAR C Z CD MAG NAIL e 'f7 ELEVATION=12.52 12.50 ^ +3'_ —S— T,d,4G NAIL `F `OP 12.5 �� -- ,� - 6� — — ? F1 EVA TI ON=I2.�9 < O (0.23)(98,016 SF)(9.3°/12) = 3,279 CF IH'/. 6.0 �ti4—� ny°� EDGE OF PAVEMENT \�:+LZ PER COAB U. y 4" w 13 TOTAL VOLUME REQUIRED: 614 CF ba Nz„vo _ },ti -: sA2 o�No i �° IRor 6' r��+ FOUND 1 /2" IRON 5' + ,Q` 1 2 5' 1— bOLUME PROVIDED: PIPE (LB 367z) 1 �:" O n� o PIPs (LB 3672 , K _ - x— X_—X—:<—X—X— %- N W ELEV. 12.0 3,398 SFwATE 2,622 CF 'w rill 1,846 SF / ,e e� a dE E� �,I 1 a a a ELEV. 11.0 / '— an� In TOTAL VOLUME PROVIDED: 2,622 CF DROP INLET 01 e— j,1 ti F ¢LL g VV 13.40 � W gym= 0 13,40 ���' e 4 U W e N 13.7 p o 13.7 a 0 o Ov yti e ., ti� a _ °,. .ti ' = O }^ o o n, w � � P k h r— g �Y s FFr 94.20 a - - f o 13.7 a a a �� i')� X18 03 fav to A 3� JF 13.7 a,: u • Fel 13.7 4 "' 12.5lb 'yo i H U � ti Q \ter 2� d U r}gam v5 n {^ 6 ',;;� ri Q U / / 2� ? s� ,� •Q ,w�"3� _� ti �T��� a �+�� a � '�,p -Q b FOUND 3'X3" CCfICRcTE MONtC� JMENT �YS��� 12.3 } --� - — — — — 1.5' r,GRTH cF�:r rr I I. / - n .} CHAIN FENCE 7 t 'G 179..0' UNK FENCE ONic RNERT�2.0' FOUND 3/�' IP.ON +�� y' n� (DI LAPID?TED) PIPE r ; + + 4- PIPE FROM IRON To MONUMENT) GARY A. ABBEY, P.E. REG. NO. 56919 PROJECT CONTACTS G1 ORGANIZATION ADDRESS TELEPHONE NUMBER CO UACT AND TITLE CITYOFATI.ANTICBEACII WATER AND SEWER 12008ANDPIPER LANE ATLANTIC BEACH, FL. 32233 (904)270-2535 NIS I U ONNA KALUZNIAK, ILITY DIRECTOR UNDERGROUND UTILITIES NOTIFICATION CENTER ONE-CALLSERVICE 81X1 3'1.4779 ) 4 D-3 EROSION AND SEDIMENT CONTROL DETAILS WATER MAIN UPGRADE - MAYPORT RD & STANLEY RD B fA ellfs 11A BITA T t"ORwff1vA*1Ty 797 MAYPORT ROAD ATLANTIC BEACH, FLORIDA 32233 DECEMBER 2014 Dl?n Tfi O P T r)0 AmrnAT INDEX OF PLANS GENERAL G1 COVER SHEET AND LOCATION MAP G2 COAB STANDARD UTILITY NOTES CIVIL C-1 WATER MAIN - STANLEY RD.. DETAILS D-1 WATER MAIN DETAILS D-2 WATER MAIN DETAILS D-3 EROSION AND SEDIMENT CONTROL DETAILS PREPARED BY: J. COLLINS ENGINEERING ASSOCIATES, LLC 11516-3 SAN JOSE BLVD. JACKSONVILLE, FL 32223 s REVISIONS BY DATE DESCRIPTION GENERAL NOTES FOR WATER AND SEWER INSTALLATION 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE EXACT LOCATION OF ALL UTILITIES AND FOR DAMAGE TO EXISTING UTILITIES CAUSED BY HIS OPERATION. CALL UTILITY CONTACTS AND SUNSHINE STATE ONE -CALL SERVICE(800-432-4770) 48 HOURS IN ADVANCE OF WORK. 2. THE CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO BIDDING 10 FAMILIARIZE HIMSELF WITH JOB SITE CONDITIONS. 3. CONTRACTOR SHALL ARRANGE FOR AND PAY FOR ALL TESTING AS REQUIRED IN THE CITY OF ATLANTIC BEACH AND/OR JEA SPECIFICATIONS PERTAINING TO THE JOB. 4. ALL WATER AND SEWER WORK SHALL BE AS PER CITY OF ATLAN C BEACH STANDARDS AND SPECIFICATIONS UNLESS SHOWN OTHERWISE. THE CITY OF ATLANTIC BEACH USES JEA STANDARD SPECIFICATIONS AND DETAILS WITH EXCEPTIONS AS SHOWN ON THE PLANS, OR IN THE NOTES. 5. UTILITY CONTRACTOR SHALL NOT COMMENCE WORK WITHOUT PRIOR NOTICE TO THE CITY OF ATLANTIC BEACH PUBLIC WORKS DEPARTMENT (247-5834). TWO DAYS NOTIFICATION IS REQUIRED BEFORE ANY LINES ARE CONNECTED TO THE EXISTING UTILITY SYSTEM. 6. ALL WATER MAINS SHALL HAVE A MINIMUM OF 30' COVER FROM FINISHED GRADE IN UNPAVED AREAS AND 36" MINIMUM COVER IN PAVED AREAS. WATER AND SEWER MAINS ARE DESIGNED TO FINISHED GRADE AND SHALL BE PROTECTED FROM DAMAGE UNTIL ALL WORK IS COMPLETED. 7. HORIZONTAL AND VERTICAL SEPARATION SHALL BE AS SPECIFIED IN CODE 62-555.314 (F.A.C.) LOCATION OF PUBLIC WATER SYSTEM MAINS: (1) HORIZONTAL SEPARATION BETWEEN UNDERGROUND WATER MAINS AND SANITARY OR STORM SEWERS, WASTEWATER OR STORMWATER FORCE MAINS, RECLAIMED WATER PIPELINES, AND ON-SITE SEWAGE TREATMENT AND DISPOSAL SYSTEMS. (A) NEW OR RELOCATED, UNDERGROUND WATER MAINS SHAIL BE LAID TO PROVIDE A HORIZONTAL DISTANCE OF AT LEAST THREE FEET BETWEEN THE OUTSIDE OF THE WATER MAIN AND THE OUTSIDE OF ANY EXISTING OR PROPOSED STORM SEWER, STORMWATER FORCE MAIN, OR PIPELINE CONVEYING RECLAIMED WATER REGULATED UNDER PART III OF CHAPTER 52-610, F.A.C. (B) NEW OR RELOCATED, UNDERGROUND WATER MAINS SHAIL BE LAID TO PROVIDE A HORIZONTAL DISTANCE OF AT LEAST THREE FEET, AND REFERABLY TEN FEET, BETWEEN THE OUTSIDE OF THE WATER MAIN AND THE OUTSIDE OF ANY EXISTING GR PROPOSED VACUUM TYPE SANITARY SEWER. (C) NEW OR RELOCATED, UNDERGROUND WATER MAINS SH L BE LAID TO PROVIDE A HORIZONTAL DISTANCE OF AT LEAST SIX FEET, AND PRTERABLY TEN FEET, BETWEEN THE OUTSIDE OF THE WATER MAIN AND THE OUTSIDE OF ANY EXISTING OR PROPOSED GRAVITY OR PRESSURE TYPE SANITARY SEWER, WASTEWATER FORCE MAIN, OR PIPELINE CONVEYING RECLAIMED WATER NOT REGULATED UNDER 'ART III OF CHAPTER 62-610, F.A.C. THE MINIMUM HORIZONTAL SEPARATION DISTANCE BETWEEN WATER MAINS AND GRAVITY TYPE SANITARY SEWERS SHALL BE REDUCED TO THREE FEET WHERE THE BOTTOM OF THE WATER MAIN IS LAID AT LEAST SIX INCHES ABOVE THE TOP OF THE SEWER. (D) NEW OR RELOCATED, UNDERGROUND WATER MAINS SHALL BE LAID TO PROVIDE A HORIZONTAL DISTANCE OF AT LEAST TEN FEET BETWEEN THE OUTSI E OF THE WATER MAIN AND ALL PARTS OF ANY EXISTING OR PROPOSED 'ON-SITE SEWAGE TREATNENT AND DISPOSAL SYSTEM' AS DEFINED IN SECTION 381.0065(2), F.S., AND RULE 64E-6.002, F.A. ,. (2) VERTICAL SEPARATION BETWEEN UNDERGROUND WATER MADS AND SANITARY OR STORM SEWERS, WASTEWATER OR STORMWATER FORCE MAINS, AND RECLAIM D WATER PIPELINES. (A) NEW OR RELOCATED, UNDERGROUND WATER MAINS CROSSING ANY EXISTING OR PROPOSED GRAVITY OR VACUUM TYPE SANITARY SEWER OR STORM SEWER SHALL BE LAID SO THE OUTSIDE OF THE WATER MAIN IS AT LEAS SIX INCHES, AND PREFERABLY 12 INCHES ABOVE OR AT LEAST 12 INCHES BELOW THE 0 [SIDE OF THE OTHER PIPELINE. HOWEVER, IT IS PREFERABLE TO LAY THE WATER MAIN ABOVE THE OTHER PIPELINE. (B) NEW OR RELOCATED, UNDERGROUND WATER MAINS CROSSING ANY EXISTING OR PROPOSED PRESSURE TYPE SANITARY SEWER, WASTEWATER OR STORMWATER FORCE MAIN, OR PIPELINE CONVEYING RECLAIMED WATER SHALL BE LAID SO THE OUTSIDE OF THE WATER MAIN IS AT LEAST 12 INCHES ABOVE OR BELOW THE OUTSIDE OF THE OTHER PIPELINE. HOWEVER, IT IS PREFERABLE TO LAY THEW TER MAIN ABOVE THE OTHER PIPELINE. (C) AT THE UTILITY CROSSINGS DESCRIBED IN PARAGRAPHS (A) AND (B) ABOVE, ONE FULL LENGTH OF WATER MAIN PIPE SHALL BE CENTERED ABOVE OR BELOW THE OTHER PIPELINE SO THE WATER MAIN JOINTS WILL BE AS FAR AS POSSIBLE FROM THE OTHEF PIPELINE. ALTERNATIVELY, AT SUCH CROSSINGS, THE PIPES SHALL BE ARRANGED SO THAT ALL WATER MAIN JOINTS ARE AT LEAST THREE FEET FROM ALL JOINTS IN VACUUM TYPE SANITARY SEWERS, STORM SEWERS, STORMWATER FORCE MAINS, OR PIPELINES CONVEYING RECLAIMED WATER REGULATED UNDER PART III OF CHAPTER 62-610, F.A.C., AND AT LEAST SIX FEET FROM ALL JOINTS IN GRAVITY OR PRESSURE YPE SANITARY SEWERS, WASTEWATER FORCE MAINS, OR PIPELINES CONVEYING RECLAIMED WATER NOT REGULATED UNDER PART III OF CHAPTER 62-610, F.A.C. (3) SEPARATION BETWEEN WATER MAINS AND SANITARY OR STORM SEWER MANHOLES (A) NO WATER MAIN SHALL PASS THROUGH, OR COME INTO CONTACT WITH, ANY PART OF A SANITARY SEWER MANHOLE. (8) WATER MAINS SHALL NOT BE CONSTRUCTED OR ALTERED TO PASS THROUGH OR COME INTO CONTACT WITH, ANY PART OF A STORM SEWER MANHOLE OR INLET STRUCTURE. WHERE IT IS NOT TECHNICALLY FEASIBLE OR ECONOMICALLY SENSIBLE TO COMPLY WITH THIS REQUIREMENT (I.E., WHERE THERE IS A CONFLICT IN THE ROUTING OF A WATER MAIN AND A STORM SEWER AND WHERE ALTERNATIVE ROUTING OF THE WATER MAIN OR THE STORM SEWER IS NOT TECHNICALLY FEASIBLE OR IS NOT ECONOMICALLY SENSIBLE), A SPECIFIC PERMIT MUST BE OBTAINEU FROM DEP PRIOR TO CONSTRUCTION OF ANY EXCEPTION. (4) SEPARATION BETWEEN FIRE HYDRANT DRAINS AND SANITARY OR STORM SEWERS, WASTEWATER OR STORMWATER FORCE MAINS, RECLAIMED WATER PIPELINES, AND ON-SITE SEWAGE TREATMENT AND DISPOSAL SYSTEMS. NEW OR RELOCATED FIRE HYDRANTS WIIII UNDERGROUND DRAINS SHALL BE LOCATED SO THAT THE DRAINS ARE AT LEAST THREE FEET FROM ANY EXISTING OR PROPOSED STORM SEWER, STORMWATER FORCE MAIN, OR PIPELINE CONVEYING RECLAIMED WAFER REGULATED UNDER PART III OF CHAPTER 62-610, F.A.C.; AT LEAST THREE FEET, AND PREFERABLY TEN FEET, FROM ANY EXISTING OR PROPOSED VACUUM TYPE SANITARY SEWER; AT LEAST SIX FEET, AND PREFERABLY TEN FEET, FROM ANY EXISTING OR PROPOSED GRAVITY OR PRESSURE TYPE SANITARY SEWER, WASIEWATER FORCE MAIN, OR PIPELINE CONVEYING RECLAIMED WATER NOT REGULATED UNDER PART III OF CHAPTER 62-610, F.A.C.; AND AT LEAST TEN FEET FROM ANY EXISTING OR PROPOSED 'ON SITE SEWAGE TREATMENT AND DISPOSAL SYSTEM' AS DEFINED IN SECTION 381.0065(2), F.S., AND RULE 64E-6.002, F.A.C. ANY EXCEPTIONS REQUIRE PRIOR APPROVAL OF DEP AND THE CITY OF ATLANTIC BEACH. 8. MECHANICAL RESTRAINTS ARE REQUIRED WHERE WAILR MAINS AND FORCE MAINS ARE TERMINATED, AT ALL TEES AND OTHER FITTINGS AS SHOWN IN JEA CONSIHUCTION DETAILS W-31, W-37 AND S-38. MECHANICAL RESTRAINTS TO BE MEGALUG TYPE. 9. UNSUITABLE MATERIALS UNDER WATER AND SEWER MAINS SHALL BE REMOVED AND REPLACED WITH SELECTED BACKFILL, PROPERLY COMPACTED TO 957. OF MAXIMUM DENSITY. 1D. THE CONTRACTOR SHALL COORDINATE THE WORK WITHIN THE CITY RIGHTS-OF-WAY WITH THE PROPER AGENCIES FOR MAINTENANCE OF TRAFFIC AND METHOD OF CONSTRUCTION AND REPAIR. 11. ALL POTABLE WATER AND SEWAGE FORCE MAINS 4 INCHES AND LARGER SHALL BE C-900 DR 18, CLASS 150, PVC OR DUCTILE IRON, CLASS 150, OR BETTER, UNLESS OTHERWISE NOTED ON PLAN SHEET. 12. ALL GRAVITY SEWER MAINS SHALL BE SDR 26 PVC CONFORMING TO ASTM D3040 OR DUCTILE IRON CLASS 50, CONFORMING TO ANSI A21.50, AS REQUIRED, OR BETTER. 13. ALL GATE VALVES SHALL BE NON -RISING STEM TYPE AND SHALL BE SUITABLE FOR 250 PSI NON -SHOCK WORKING PRESSURE. GATE VALVES SHALL BE MECHANICAL JOINT OR FLANGED, VALVES SHALL BE IRON BODY, BRONZE FITTED. VALVES SHALL BE CLOW, M&H, MUELLER, OR APPROVED EQUAL VALVE BOXES WITH SCREW EXTENSIONS SHALL BE OF CAST IRON CONSTRUCTION, 3/8 INCH MINIMUM WALL THICKNESS AND SHALL BE NON - TACKY TAR ENAMEL COATED. THE WORD 'SEW'ER" SHALL BE CAST IN THE COVER FOR VALVES ON FORCE MAIN. ALL GATE VALVES INSTALLED SHALL OPEN BY TURNING TO THE LEFT (COUNTER -CLOCKWISE) WHEN VIEWED FROM THE TOP. VALVES SHALL HAVE RESILIENT SEALS. 14. HYDROSTATIC AND LEAKAGE TESTING, AND DISINFECIION OF THE WATER MAINS INSTALLED SHALL BE PERFORMED IN ACCORDANCE WITH AWWA STANDARDS AND FAC CHAPTER 62-555 . A REPRESENTATIVE OF THE CITY OF ATLANTIC BEACH MUST BE PRESENT DURING THE HYDROSTATIC AND LEAKAGE TEST. THE TEST IS TO BE CERTIHED BY A REPRESENTATIVE OF THE DESIGN ENGINEER. 15. FLUSHING AND DISINFECTING OF WATER MAINS TO BE COORDINATED WITH CITY OF ATLANTIC BEACH PUBLIC UTILITIES DEPARTMENT. 16. BACTERIOLOGICAL TESTING OF WATER MAINS TO BE PERFORMED BY DOH CERTIFIED LABORATORY, PAID FOR AND ARRANGED BY CONTRACTOR. COORDINATE ALL ACTIVITIES WITH CITY INSPECTOR. 17. NO CONNECTION TO EXISTING POTABLE WATER SYSTEM SHALL BE ALLOWED UNTIL ALL PROPOSED WATER LINES HAVE BEEN PRESSURE TESTED, DISINFECTED AND CLEARED FOR SERVICE. 18. POST CONSTRUCTION TELEVISION INSPECTION AND 5% DEFLECTION TEST SHALL BE REQUIRED ON ALL GRAVITY SEWER. A FULL REPORT AND TAPE OR CD AS TO CONDITION OF THE PIPE WTH PERTINENT DATA SUCH AS DISTANCE BETWEEN MANHOLES, LOCATION OF SERVICES, ETC., SHALL BE SUBMITTED TO THE ENGINEER AND CITY OF ATLANTIC BEACH. ANY DEFECTS ENCOUNTERED SHALL BE REPLACED OR REPAIRED PRIOR TO FINAL ACCEPTANCE. ALL REPAIRED SECTIONS MUST BE REINSPECTED PRIOR TO ACCEPTANCE. 19. SHOP DRAWINGS ARE REQUIRED AND MUST BE APPROVED BY THE CITY BEFORE CONSTRUCTION. 20. ALL INSPECTIONS AND TESTING SHALL BE COORDINATED WITH THE CITY. 21. THE CONTRACTOR SHALL SECURE ALL NECESSARY PERMITS TO WORK IN EXISTING RIGHTS-OF-WAY. 22, ALL DISTURBED AREAS SHALL BE SODDED OR SEEDED AND MULCHED AS DIRECTED OR SHOWN, AND AT A MINIMUM RESTORED TO PRECONSTRUCTION CONDITION. IFILE NO I 23. EXISTING ASPHALT SHALL BE SAW -CUT IN STRAIGHT LINES FOR ALL TRENCHES. ANY DAMAGE TO CITY STREET CURB, SIDEWALK, OR OTHER MATERIAL SHALL BE REPAIRED AS DIRECTED AND APPROVED BY THE DIRECTOR OF PUBLIC WORKS. DENSITY TESTING MUST BE COORDINATED WITH THE PUBLIC WORKS INSPECTOR 24. THE CONTRACTOR SHALL FURNISH AND INSTALL FITTINGS AS NECESSARY TO ROUTE PIPES AROUND OTHER PIPES OR OBSTRUCTIONS AS REQUIRED. 25. ALL EXISTING UTILITIES HAVE BEEN SHOWN ON THE PLANS FROM THE BEST AVAILABLE INFORMATION. THE OWNER SHALL NOT BE HELD RESPONSIBLE FOR INACCURACIES OR OMISSIONS IN THE LOCATIONS OR GRADE OF FACILITIES OF THIS TYPE, THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR LOCATION OF ALL UTILITIES IN CONSTRUCTION AREA. LOCATION SHALL BE MADE IN ADVANCE OF CONSTRUCTION IN ORDER THAT CONFLICTS - 91PAVEMENT, T ( c � MAY BE RESOLVED. N 26. ALL PIPING ARRANGEMENTS AND LOCATIONS, AND LOCATIONS OF PIPING NOT SHOWN, SHALL BE PROPERLY v REFERENCED AND RECORDED ON THE RECORD "AS -BUILT" DRAWINGS. L O N 110 27.8D0(XMXRXXXMXXARXAIXXBRDffMAO&X)dMO)EoMN»(M�AUgAXdLVDWNYi(XCUNM)iEXE MBR>A MAKK O U > N N R6NEMdNXJ(AtFP%7G6ECMRX6g MWMNBXOI' MNN>mwKx>ammAXXM *wxxxxxxxXXXXXXXXXXXXXXXXXX N J 53 ro a W - m 28. ALL NEW SANITARY SEWER PIPE SCHEDULED TO REPLACE EXISTING GRAVITY SANITARY SEWER SHALL BE fn o oo INSTALLED AT EXISTING MANHOLE INVERT ELEVATIONS, AND WITH UNIFORM SLOPE OR GRADE BETWEEN C (D - u: INVERTS. GRADE SHOWN ON PLANS MAY BE ADJUSTED AS APPROVED BY ENGINEER. PREPARE CUT SHEETS W WITH INVERTS AND CALCULATED GRADE PER SPECS. O 'O m -� cO 29. ALL EXISTING WATER PIPE, INCLUDING SERVICES SCHEDULED TO BE ABANDONED, SHALL BE REMOVED IF WITHIN (o N TRENCH OF NEW WATER MAIN, OR WITHIN TRENCH OF NEW SERVICE, UNLESS OTHERWISE DIRECTED. O c: _� C.i 30. IF WATER IS NEEDED FOR CONSTRUCTION ACTIVITY, A CONSTRUCTION METER AND BACKFLOW PREVENTER N SHALL BE OBTAINED FROM CITY OF ATLANTIC BEACH PUBLIC UTILITIES DEPARTMENT. -7 0 m 31. ALL FIRE HYDRANTS TO BE PAINTED YELLOW. OPEN LEFT. INSTALL BLUE HYDRANT MARKER IN ADJACENT I IF PAVEMENT. r 32. ALL WATER AND SEWER SERVICE AND VALVE LOCATIONS SHALL BE APPROPRIATELY MARKED AS FOLLOWS (SAW CUT). WATER SERVICE - "W" ON TOP OF CURB. (6' FROM EDGE OF PAVEMENT IF NO CURB & GUTTER) SEWER SERVICE - 'S" ON TOP OF CURB. (6' FROM EDGE OF PAVEMENT IF NO CURB & GUTTER) VALVE - 'V' ON TOP OF CURB. (6" FROM EDGE OF PAVEMENT IF NO CURB & GUTTER) 33. ALL WATER SERVICES SHALL BE SCHEDULE 40 PVC. NO POLY SERVICES PERMITTED. ALL SERVICES MUST HAVE DOUBLE STRAP TAPPING SADDLES WITH CORP. STOPS AT THE MAIN. Q 34. WATER METER BOXES TO BE DOUBLE WALL PLASTIC WITH TOUCH -READ LID AS AVAILABLE FROM SUN STATE OC METER & SUPPLY. 35. MANHOLE COVERS TO BE PAM REX-HINGED COVERS AVAILABLE THROUGH PORTER ASSOCIATES, 352-589-5888. � 36. ALL SEWER SERVICES MUST HAVE INDIVIDUAL CLEANOUTS AT THE PROPERTY LINE. Z 37. MAINTENANCE OF TRAFFIC PLANS TO BE SUBMITTED TO CITY ENGINEER 7 DAYS PRIOR TO START OF CONSTRUCTION. COORDINATE IN FIELD WITH CITY INSPECTOR. 38. ALL WATER/SEWER CONSTRUCTION MUST BE PERFORMED BY A FLORIDA LICENSED UNDERGROUND UTILITY CONTRACTOR. 39. LOCATE WIRING - LOCATE PARING SHALL BE INSTALLED ON ALL PVC, DI AND HDPE WATER MAIN PIPING Q AND SERVICES LARGER THAN TWO INCHES, AND SHALL BE TESTED AS PER JEA SPECIFICATIONS. DC 40. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY AND AT THE CONTRACTOR'S EXPENSE TO PROVIDE THE CITY OF ATLANTIC F BEACH WITH "AS -BUILT' DRAWINGS ON MYLAR OR IN FORM AS REQUIRED BY THE CITY, AS WELL AS ELECTRONIC FILES IN AUTOCAD 2004 OR BETTER USING NAD 1983 STATE PLAN FLORIDA EAST FIPS 0901 (feet). (VERTICAL CONTROL WILL BE O N.AV.D. 1988). THE CITY'S INSPECTOR AND GIS TECHNICIAN SHALL BE GRANTED ACCESS TO THE SITE AND TO AS BUILT DRAWINGS DURING CONSTRUCTION. r 41. CONTRACTOR SHALL CONDUCT TESTING TO DETERMINE IF POLYETHYLENE WRAPPING OF DUCTILE IRON FITTINGS IS REQUIRED, AS SPECIFIED IN AWWA-C105, APP. A. RESULTS, WITH CONTRACTOR RECOMMENDATIONS, e WILL BE PROVIDED TO PUBLIC UTILITIES DIRECTOR PRIOR TO BEGINNING CONSTRUCTION. N.1 e 42. HORIZONTAL DIRECTION DRILLING (HDD) OPERATIONS SHALL BE IN COMPLIANCE WITH JEA WATER AND SEWER STANDARDS MANUAL SECTION 750. a FOR ALL OTHER PROJECT NOTES, SEE PLAN SHEETS OR SPECIFICATIONS. IF CONFLICTS ARISE BETWEEN PLAN NOTES AND W SPECIFICATIONS, PLAN NOTES WILL GOVERN. CAM Z w `0 Ca G R11G W 1-� Q 3 DATE DEC. 2014 SCALE AS SHOWN DRAWN BY JEC JOHN E. COLLINS, JR PE$40085 DESIGNED BY JEC SHEET G-2 COAB STANDARD UTILITY NOTES 2 OF 6 SHEETS STANLEY ROAD STANDLEY ROAD BY PLAT 30' RIGHT-OF-WAY BY PLAT ABANDON 2' WM. - CLOSE CORP STV/�(N OR VALVE @ 16" WM. REMOVE 2" GS & PLUG CORP STOP. UND IRON PIPE EXIST. BLDG. CAP) INSTALL NEW 16" X 8/yr2—GALV_ — —w TAPPING VALVE (o INSTALL Af & VALVE BOX (APPROX. —__ W- 130' NEW 8"PVC WM — 2^ GALV. LOCA ON OF WATE METEF INSTALL NEW 1"WM SERVICE TO EXIST. METER, 8" X1" TAPPING SADDLE, 1" CURB STOP & 1" CORP STOP. INSTALL NEW FH, 8"X6" TEE, 6" WM PIPE, 6" 90 DEGREE BEND ,6" GV & BOX/COVER. COORD. _ LOCATION OF FH WICITY (APPROX. 26' FROM PL CORNER). ABANDON 2' WM. INSTALL NEW 2" PVC WM, 2"90 DEGREE _ BEND, 8" X2" TAPPING SADDLE, +� —2" CORP STOP. INSTALL 8" PIPE PLUG. +v / \• nuu� ur rrw�mu `o" EUGE OF PAVEMEIV I 9 //3 +pry BENCHMARK +,ti' INSTALL NEW DOUBLE +,ti' ^ryy SANITARY MAj`1HOLE MAG NAIL WMSERVICE ti69+ +BENCHMARK TOP 12 .5 ELEVATION=12.52. 10" V.C. _ 10" V.C. J, _�.;.� --oti — S MAG NAIL IHV 6 0 o ryb S EDGE OF PgVEMEN yy ELEVATION=12.59 PER COAG .U. y FOUND 1/2" IRON 6 ^6 +,ry' • .ti0ry .d°, •..d s ti bo- 'W. ry PIPE (LB 3672) ,, d•.A. W NI ry q PIP<`' LB' 367 WATE METE / DROP •/ & 1 < I 1 ��� INLET y" A., I . d.. I Q 3Qe 0 / � y — / — — — by ry � — — ryyry { cp � ^ry5 .ry. J � + n I �' 1^�• I Z ¢ Q cn I u a Q / 20 a'n 0 °10.° 2 e• I 1 S' ^`O CAC,EINf.E T d U iZ C ti yy y C UNIT D a U / + UNIT A UNIT B i UN(f 1 ���� I y �+ ( / PROPOSED 2 STORY BUILDING, / I 3 BEDROOMS PER UNIT / I 1795 MAYP ORT ROAD �y 00 ' 00 — — — — y — -- — — — — . — — — — — 1..��� �•e _1 — — — — — — — — 1 — — 1� — — — p � — •� - — ti O h 6 Q- 3 ti� I 1 a 1 CIV,�9�st X—X— X—X— X— X— X—X- O NOTE: REFER TO CITY UTILITY STD. & DETAILS FOR CONSTRUCTION. ^ ; I a 1 o,F, O FOUND 3"X3" CONCRETE ,, •yti+ - `+ Q I ` I ,yyo- I '� MONUMENT (NO ID) I 1 Db ----- .. I + —\ I-&l—ll — --------- 1.5X NOf H X—X—X— N aT 1_ N N Uj N N m�mc a o i� vi o 0 ca�rLL y+ C W U) 0 0 �D 0 N 0 Tn u1 Y N U Q l0 N I U E w -- DEC. 2014 SCALE AS SHOWN DRAWN BY JEC JOHN E. COLLINS, JR PE#40085 s DESIGNED BY JEC SHEET C-1 NEW WATER MAIN 3 OF 5 SHEETS PVC PIPE RESTRAINT NOTES: 41 4. 1) THIS SCHEDULE SHALL BE UTILIZED ON ALL WATER, SEWER FORCE MAIN OR RECLAIMED WATER SYSTEMS. ALL FITTINGS SHALL BE RESTRAINED TO LENGHTS INDICATED ON THE ABOVE SCHEDULE, AT A MINIMUM. 2) ASSUMPTIONS: PVC PIPE, SAFETY FACTOR=1.5, TEST PRESSURE= 15OPSI, SOIL=GM OR SM, TRENCH TYPE 3, DEPTH OF COVER=30 INCHES FOR 20" AND SMALLER PIPE SIZE OR 36 INCHES FOR 24" AND LARGER PIPE SIZE. 3) BENDS AND VALVES: SHALL BE RESTRAINED ON EACH SIDE OF FITTING. 4) VERTICAL OFFSETS: ARE APPROX. 3 FEET COVER ON TOP AND APPROX. 8 FEET COVER ON BOTTOM. PER THE DETAILS, Lu IS THE RESTRAINED LENGTH FOR THE UPPER (TOP) LEVEL U IS THE RESTRAINED LENGTH FOR THE LOWER (DEEPER) LEVEL. ASSUME 45 DEGREE BENDS. 5) TEES: TOTAL LENGTH BETWEEN FIRST JOINTS OR RESTRAINED LENGTH ON EITHER SIDE OF TEE (RUN) SHALL BE A TOTAL DISTANCE OF 30 FEET (MIN). SEE SCHEDULE ABOVE FOR RESTRAINT LENGTH ON TEE "BRANCH* LINE. 6) HDPE TO PVC TRANSITIONS: THE PVC PIPE SIDE SHALL BE RESTRAINED 35 FT (MIN). 7) THE INSTALLATION OF BELL HARNESS RESTRAINTS AT PVC JOINTS (DR -18 & 25 PIPE) SHALL BE COMPLETED PER THE MANUFACTURERS RECOMMENDATION, WHICH INCLUDES NOT OVER TIGHTENING THE PARALLEL RODS/NUTS. THESE NUTS SHOULD ONLY BE SNUG TIGHT, THE HOME MARKS ON THE PIPE SHOULD ALWAYS BE VISIBLE AFTER THE RESTRAINT IS INSTALLED. OVERHOMING THE JOINT MAY CAUSE A FAILURE AT THE BELL RESULTING IN A SERVICE OUTAGE. LOCATE WIRE BOX PVC PIPE RESTRAINT JOINT SCHEDUI.E UTILIZING WITH EXISTING CONDITIONS. CO -POLYMER METER ( CONNECT WIRES LENGTH (L) TO BE RESTRAINED TOGETHER WITH IRON OR PVC (PRESSURE MAINS). LOCATE V WIRE NUT) (SEE NOTE PIPING (1:00 OR 11:00 POSITION, IF POSSII d8) 2. SECURE LOCATING WIRE TO PVC & D.I.P. W, AS REQUIED TIE STRAPS SPACED AT A MAXIMUM DISTANC NOMINAL FlTTING. HORIZONTAL BENDS 3. THE ENTIRE LOCATING SYSTEM SHALL BE SL VERTICAL OFFSETS VALVES REDU ERS TEES NOTE 5 PIPE 90' 45' 22.5' 11.25' 45' BENDS OR 5. LOCATING WIRE SHALL BE 10 GAUGE, SINGLI VALVE BOX W/VALVE SEE PLATE 30 MIL (MIN.) INSULATION WITH EITHER WHIT S -49B WIRE SHALL BE COPPER CODED STEEL AS SIZE BENDS BENDS BENDS BENDS SEE NOTE 4 DEADENDE SIZE L RUN BRANCH L (IN.) L(FT.) L.(FT.) L. (Fr.) L(FT.) LU(FT.) U(FT.) L(FT.) IN LOCATE WIRE BOX SIZE SIZE FT 4 20 8 4 2 20 3 50 674 8X6 35 35 4" 4" F.0 6 28 10 52 28 4 70 6" 6" 10 BX4 10X8 10X6 12X10 12X8 16X12 16X10 20X18 20X12 65 35 65 35 65 65 95 35 65 120 4^< LESS F.0 8 36 14 6 3 36 5 90 8" B 6"< LESS 30 F.0 10 40 18 8 4 45 6 110 12 50 20 9 4 52 8 120 10" 10" 8" 6% LESS 48 14 F.O. 14 56 23 10 5 60 9 140 16 60 26 11 6 67 10 160 2" 16' 12" 10" 8'< LESS 16" 65 3520X16 F.O. 100 18 69 29 12 6 74 12 180 20 75 32 13 7 80 13 195 24 76 33 15 7 81 14 200 24X20 24X18 24X16 3OX24 30X20150 36X30 36X24 65 95 120 80 80 150 12" 0"< LES 40 F.0 30 88 36 18 9 97 16 235 20" 20' 16" 2'< LES 130 80 F.0 36100 40 20 10 110 20 270 42 115 48 23 11 125 24 300 48 125 52 25 12 140 30 340 24" 24" 20' 130 90 PVC PIPE RESTRAINT NOTES: 41 4. 1) THIS SCHEDULE SHALL BE UTILIZED ON ALL WATER, SEWER FORCE MAIN OR RECLAIMED WATER SYSTEMS. ALL FITTINGS SHALL BE RESTRAINED TO LENGHTS INDICATED ON THE ABOVE SCHEDULE, AT A MINIMUM. 2) ASSUMPTIONS: PVC PIPE, SAFETY FACTOR=1.5, TEST PRESSURE= 15OPSI, SOIL=GM OR SM, TRENCH TYPE 3, DEPTH OF COVER=30 INCHES FOR 20" AND SMALLER PIPE SIZE OR 36 INCHES FOR 24" AND LARGER PIPE SIZE. 3) BENDS AND VALVES: SHALL BE RESTRAINED ON EACH SIDE OF FITTING. 4) VERTICAL OFFSETS: ARE APPROX. 3 FEET COVER ON TOP AND APPROX. 8 FEET COVER ON BOTTOM. PER THE DETAILS, Lu IS THE RESTRAINED LENGTH FOR THE UPPER (TOP) LEVEL U IS THE RESTRAINED LENGTH FOR THE LOWER (DEEPER) LEVEL. ASSUME 45 DEGREE BENDS. 5) TEES: TOTAL LENGTH BETWEEN FIRST JOINTS OR RESTRAINED LENGTH ON EITHER SIDE OF TEE (RUN) SHALL BE A TOTAL DISTANCE OF 30 FEET (MIN). SEE SCHEDULE ABOVE FOR RESTRAINT LENGTH ON TEE "BRANCH* LINE. 6) HDPE TO PVC TRANSITIONS: THE PVC PIPE SIDE SHALL BE RESTRAINED 35 FT (MIN). 7) THE INSTALLATION OF BELL HARNESS RESTRAINTS AT PVC JOINTS (DR -18 & 25 PIPE) SHALL BE COMPLETED PER THE MANUFACTURERS RECOMMENDATION, WHICH INCLUDES NOT OVER TIGHTENING THE PARALLEL RODS/NUTS. THESE NUTS SHOULD ONLY BE SNUG TIGHT, THE HOME MARKS ON THE PIPE SHOULD ALWAYS BE VISIBLE AFTER THE RESTRAINT IS INSTALLED. OVERHOMING THE JOINT MAY CAUSE A FAILURE AT THE BELL RESULTING IN A SERVICE OUTAGE. LOCATE WIRE BOX NOTES: UTILIZING WITH EXISTING CONDITIONS. CO -POLYMER METER ( CONNECT WIRES 1. LOCATING WIRE TO BE INSTALLED IN EITHER TOGETHER WITH IRON OR PVC (PRESSURE MAINS). LOCATE V WIRE NUT) (SEE NOTE PIPING (1:00 OR 11:00 POSITION, IF POSSII d8) 2. SECURE LOCATING WIRE TO PVC & D.I.P. W, AS REQUIED TIE STRAPS SPACED AT A MAXIMUM DISTANC 3/4" COLD ROLL STEEL ROD CUT AND THREAD AS FlTTING. 3. THE ENTIRE LOCATING SYSTEM SHALL BE SL INSTALLED UNDER PAVEMENT AREAS, TESTIN( UNLESS APPROVED OTHERWISE BY OWNER. 4" or LARGER BRANCH FORCE MAIN 4. LOCATING WIRE SHALL TERMINATE WITHIN AN IF NO VALVE ) AT 475' INTERVALS. WIRE CC SEE PLATE AVOIDED. 5-49A LOCATE WIRE BOX UTILIZING 5. LOCATING WIRE SHALL BE 10 GAUGE, SINGLI VALVE BOX W/VALVE SEE PLATE 30 MIL (MIN.) INSULATION WITH EITHER WHIT S -49B WIRE SHALL BE COPPER CODED STEEL AS x' 6. INDICATES THAT THE WIRES ARE CONI ' @ DUCT TAPE OR ZIPPER 7. INDICATES A WIRE PIG -TAIL (12' L TYPE PLASTIC TIES B. AN "LW" CUT SHALL BE CARVED IN THE COI LOCATE WIRE BOX UTILIZING VALVE WATER MAIN BOX W/VALVE SEE PLATE 5-49B LOCATE WIRE CONE LOCATE WIRE SHALL TERMINATE IN LOCATE WIRE BOX BRANCH VALVE BOX OR DEAD END PLUGGED LOCATE BOX REO. (SEE OTE hl PVC PIPE RISER 10' MAX SPACING IF 24" 80 20" 50 6'< LESS F.O. 36" 36" 180 30" 120 24" 50 20"<LESS F.O. 42" 42" 220 36" 160 30BO 24" 40 O'< LES F.0 48' 48" 250 42" 180 36" 90 N.. HORIZONTAL BEND o a ♦ ANGLE OF DIRECTION CHANGE N L. DEAD END UPPER BEND J b' \ W ANGLE OF 4Y �� REyiR,.1N Tali. j x DIRECTIONN.. a CHANGE RUN a LOWER BEND *♦ ► o ANGLE OF 45' u DIRECTION w CHANGE VERTICAL OFFSET PROFILE �no BRANCH Z N � E TEE ♦ ♦♦ 414` RUN VALVE NOTES I. TOTAL LENGTH BETWEEN FIRST JOINTS OR RESTRAINED LENGTH ON EITHER SIDE OF TEE (RUN) SHALL BE A TOTAL DISTANCE OF 30 FEET (MIN.). 2. PAY ITEM DENOTES A RESTRAINT WHICH IS PAID FOR ON A PER EACH BASIC. 3. PAY ITEM '••" DENOTES A RESTRAINT WHICH IS INCLUDED IN THE UNIT PRICE BID FOR FITTING OR VALVE. .,,,F FOR FIRE HYDRANT INSTALLATION - FU AND INSTALL I BI-DIRECTIONAL RAISED ear 31 F WDS TYPICAL PROFILE SECTION TYPICAL PROFILE BELL M EO PWN END 4EDNNMAI JOIM i0 PtAPI ENO W/MECHNIM.LL RESIRNNERS w/4ECHWIfIL REj�jS,TWiWERg�-1 L.. V� MECHANICAL JOINT SLEEVES REDUCER NUMRER OF THE RODS REWIRED NE ROOS 14'-20' MAIN - 6 RODS 24"-38' MIN - 6 RODS 42"-18' MN - 10 RODS PLuc DEAD - END THRUST COLLAR ANCHOR TO 6E USED INSTEAD OF TOTAL REST INED IENOTH (OP11011AQ SIZE AS PER -UST BLOD( DETNL SHEET D-3 GENERAL NOTE 1. y NDICATES DIF6:CTON OF (WATER HNAMER) FORCE MARKER, BLUE ON BOTH FACES, NOTE: DIMENSIONS MAY VARY LOCATETI T AT PAVEMENT C EACH HYDRANT WITH EXISTING CONDITIONS. ATTACH PAVEMENT ATTACH TO FINISHED PAVEMENT WITH EPDXY, ADJUST LENGTHS AND FITTINGS. USING STANDARDS AND MATERIALS STATED IN FDOT SPEC. SECTION 706. DEPTH OF BURY. HYDRANT COLOR YELLOW (TYP) n n CORROSION RESISTANT STEEL. GALVANIZED AS REQUIED w 3/4" COLD ROLL STEEL ROD CUT AND THREAD AS PUMPER NOZZZLE TO FACE STREET IE ONE OR ELEVEN O'CLOCK POSITION ON ALL DUCTILE STANDAIII MECH. JOINT REQUIRED SHALL ALSO BE INSTALLED ON ALL (HDPE) POLY MAIN TEE SIZED AS REQUIRED_ 30' MIN. I R MAIN BY USE OF DUCT TAPE OR ZIPPER TYPE PLASTIC OF TEN (10') AND AT EACH SIDE OF BELL JOINT OR ECTED TO TESTING TO DETERMINE ITS RELIABILITY. WHERE (HALL BE DONE PRIOR TO THE PLACEMENT OF PAVEMENT, ;TIVE VALVE BOX ( WITH A VALVE ) OR A METER BOX ( IECTIONS BELOW GROUND (OUTSIDE OF A BOX) SHALL BE ITRAND, OF RATED (DIRECT BURIAL), COPPER WIRE WITH OR YELLOW COLOR. FOR HDD INSTALLATIONS, THE LOCATE CIFlED IN SPEC. SECTION 750. TED TOGETHER. CURB AND PAINTED AT ALL LOCATE WIRE BOXES. WATERMAINS BOX ACCESS (SEE NOTE 2) ^V' CUT IN 6' PVC PIPE RISER rYOCATING WIRE PARALLEL TO MAIN —FORCE MAIN �lIII'1(�ollllll� "TOPEECH. JT. 6" VALVE N LEFT USE 3/4' NUTS BOTH; HYDRANT SUMP SIDES OF JOINT (TYPICAL) SEE BELOW USE "GRADELOK' CONNECTOR OR USE CONCRETE THRUST EQUAL, WITH 12" MIN. ADJUSTMENT BLOCK AS DIRECTED 7WATER MAIN 3 -WAY FIRE NOTE: HYDRANT FIRE HYDRANTS SHALL BE INSTALLED 1 1/4" Sq. NUT AT LOCATIONS AS SHOWN ON THE OPEN LEFT 'c PLANS EXCEPT WHERE CONDITIONS AND/OR REGULATIONS PROHIBIT. FRANGIBLE FLANGE LOCATION FOR "TRAFFIC' TYPE HYDRANT. FINISHED 3000A CONCRETE SLAB " GRADE p4 REBAR 0 12" O.C. EACH WAY WATER VALVE BOX of PE RODS, NUTS, WASHERS AND OTHER HYDRANT EXTENSION AS REOUIRED FOR ADDITIONAL FASTENERS SHALL BE ASTM A246 DEPTH OF BURY. - n n CORROSION RESISTANT STEEL. GALVANIZED AS REQUIED w OR TYPE 316 STAINLESS STEEL �\ 30' MIN. 0 —3/4" ROD, 2 REQUIRED SECTWIREO PIPE WI DUCZIPPER TEE OR SADDLETYPETIE STRAP USE `GRADELOK' CONNECTOR OR 4' AND LARGER BRANCH EQUAL, W1TH 12" MIN. ADJUSTMENT LOCMAIN SERVICE OR BRANCH WATER MAIN FIRE HYDRANT ASSEMBLY (4" AND LARGER SEWER N.T.S. MAIN) MUELLER, AMERICAN STANDARD OR EQUIVALENT ( PROPOSED EQUIVALENT TO BE APPROVED BY COAG) GRAVEL OR BROKEN ROCK FOR HYDRANT SUMP, COVER GRAVEL WTH 30I FELT CONNECT WIRE �- TOGETHER WITH BOX ACCESS (SEE NOTE 1) ELECTRICAL WIRE NUT. PROVIDE 12' PIG TAIL LOCATE WIRE VALVE BOX I--�I�f DUCT TAPE OR ZIPPER I 1 II r—FORCE MAIN TYPE PLASTIC TIE STRAPS LOCATE WIRE BOX UTILIZING VALVE BOX INSTALL CO -POLYMER METER BOX WITH HEAVY-DUTY IRON UD (PAINT TOP OF UD) (POSITION BOX PARALLEL WITH? PROVIDE 3" THICK— GRAVEL BOTTOM 2" PVC RISER PIPE— DUCT TAPE OR ZIPPER TYPE PLASTIC TIE STRAPS CONNECT WIRES TOGETHER WITH ELECTRICAL WIRE NUT. (PROVIDE 12" LONG PIGTAIL ENDS) LOCATING WIRE (ROUTED IN PIPE) FORCE MAIN LOCATE WIRE BOX UTILIZING METER BOX 1. LOCATE WIRE SHALL ENTER THE VALVE BOX THROUGH A Y' CUT IN THE 6' PVC RISER PIPE. JOHN E. COLLINS, JR PE#40085 WATER MAIN DETAILS IFILE NO I 6 W J Z a H Ax IX O 9L 5a W ad 0 9L Z 5a W a iQ DATE DEC. 2014 SCALE AS SHOWN DRAWN BY JEC DESIGNED BY JEC D-1 4 OF 6 SHEETS Ti PAINT COVER AND INSIDE OF BOX GREEN COMPACTED EARTH (TYP) VALVE BOX & COVER (TYP) PROVIDE GREEN PAINT TO THE INSIDE OF THE TOP SECTION OF THE BOX (NOTE 5) 6" PVC RISER PIPE (LENGTH AS REQUIRED) PROVIDE "V" CUT IN TOP OF 6" RISER PIPE FOR LOCATE WIRE ACCESS INTO VALVE BOX. PLASTIC DEBRIS SHIELD REQUIRED ON— ALL VALVES 12" AND SMALLER. (NOTE 8) RESTRAINED MECHANICAL JOINT (TYP) APPLY GROUT TO FILL ANNULAR SPACE BETWEEN VALVE BOX AND CONCRETE PAD 24" ROUND PRECAST CONCRETE PAD 4" THICK (SEE SPEC) SET ON COMPACTED EARTH, (SEE NOTE 6) VALVE BOX ADJUSTMENT (SEE NOTE 5) FINISHED GRADE GATE VALVE W/ 2" OPERATING NUT (NOTE 4) PIPE W/ LOCATING WIRE UNDISTURBED EARTH J p� ' 1 • 12" (MIN) LAYER OF #57 STONE (REQUIRED FOR VALVES 20" AND LARGER, (NOTE 7) NOTES: 1. FOR UNPAVED LOCATIONS, A PRECAST CONCRETE VALVE PAD SHALL BE PROVIDED AND INSTALLED FLUSH WITH GRADE. CONCRETE PAD IS NOT REQUIRED FOR VALVE LOCATED 114 THE ROADWAY, UNLESS SHOWN OR NOTED OTHERWISE. 2. LOCATING WIRE IS REQUIRED ON ALL PRESSURE PIPING 3. A "V" CUT SHALL BE CARVED IN THE CURB CLOSEST/ADJACENT TO ALL BELOW GRADE VALVES. THE "V" CUT IS TO BE PAINTED GREEN. 4. IN PAVED AREAS, INSTALL VALVE AT A DEPTH TO ALLOW A 12" MIN. DISTANCE BETWEEN THE VALVE COVER PLATE AND THE TOP OF THE VALVE OPERATING NUT. OUTSIDE 0- PAVED AREAS (GRASS), INSTALL VALVE AT A DEPTH TO ALLOW A 6" MINIMUM DISTANCE BETWEEN THE VA L E COVER AND THE TOP OF THE VALVE OPERATING NUT. OPERATING NUT/STEM EXTENSION SHALL BE PROVIDED (WHERE APPLICABLE) SO THAT THE OPERATING NUT WILL BE NO MORE THAN 24 INCHES BELOW FIN SHED GRADE. 5. FOR NEW CONSTRUCTION, THE VALVE BOX SHALL BE ADJUSTED TO MIDRANGE TO ALLOW FOR FUTURE BOX ADJUSTMENTS. ROUTE LOCATE WIRES THRU A "V" CUT IN THE TOP OF THE 6" PVC RISER PIPE FOR LOCATE WIRE ACCESS INTO VALVE BOX. THE LOCATE WIRES WITH A 12" _ONG PIG -TAIL AT THE TOP SHALL BE CONNECTED TOGETHER WITH A WIRE NUT. 6. BRASS IDENTIFICATION TAG INDICATING "SEWER", VALVE SIZE, DIR-CTION AND TURNS TO OPEN & VALVE TYPE. PROVIDE A Ya" HOLE IN BRASS TAG AND ATTACH TAG (TWIST W RE AROUND TAG) TO THE END OF THE LOCATE WIRE. TAGS ARE NOT REQUIRED ON VALVES INSTALLED CIA FIRE HYDRANT BRANCH LINES. 7. IN LIEU OF PRECAST CONCRETE PAD, A 6' THICK X 24" (ROUND OR SQUARE) POURED CONCRETE PAD W/2 - #4 REBAR AROUND PERIMETER, MAY BE USED. 8. GRAVEL SHALL BE PROVIDED UNDER ALL VALVES 20" AND LARGER. THE MINIMUM VERTICAL LIMIT OF GRAVEL IS 12" UNDER THE VALVE UP TO YS THE OVERALL HEIGHT OF TiE VALVE. 9. FOR VALVES 12 INCH AND SMALLER, PROVIDE A WHITE OR BLACK PLASTIC DEBRIS SHIELD WHICH INSTALLS BELOW THE OPERATING NUT. THIS SHIELD SHALL CENTER THE RISER PIPE BOX OVER THE OPERATING NUT AND MINIMIZE INFILTRATION. SHIELD SHALL BE BY AFC, BOXLOK OR APPROVED EQUAL. PAINTO INSIDE (SEE NTE 1) (2) 1" DIA. PICKHOLES 16' 1) PAINT TOP OF THE COVER WITH ENAMEL PAINT (GREEN COLOR). HEAVY DUTY RATING NOTES: 1) PAINT 2) HEA4 VALVE BOX �aw, U_� -mss f-5-11/16'. /2 - BOTTOM BOTTOM SECTION VIEW (26 LBS. APPROX.) OF THE TOP SECTION OF THE BOX GREEN COLOR. IG (TOTAL WEIGHT APPROX 50 LBS.) AIL CROWN /-COLD MIX "•IIIo�► I.:J,IQIII�00a �f•II• IIII�II•po0 AL- AL - .................... 98% COMP. AASHTO I -III :.'.'.':.'............'.'.'.'.'.'. � � (- CASE X - TEMPORARY TYPE II REPAIR NOTE: NOT TO SCALE AFTER REPAIR IS COMPLETE, MILL & RESURFACE. (REMOVE 1" ASPHALT AND REPLACE W/ MIN. 1 Y2" ASPHALT 1 R/W LINE WATER MAIN PROPERTY LINE SIZE VARIES ROADWAY TO R/W LINE VARIES rMETER BOX PROVIDED AND INSTALLED BY i CONTRACTOR BORE AND JACK UNDER W/CURB STOP AND METER PAVED ROADWAY AND CURB 1-1/2"x3/4" RED. SEE SPECIFICATIONS AND STANDARDS ROADWAY WIDTH VARIES 7j-1-1/2" CORPORATION STOP r- 5' TYP _ PROPERTY UNE 1-1/2" SCH, 40 PVC 22 1. FOR WATER SERVICE TO OTHER SIDE, USE SIMILAR METHODS AND MATERIALS.. J NO. NO CONNECTION TO EXISTING POTABLE SYSTEM SHALL BE ALLOWED UNTIL SERVICE PIPING ALL NEW WATER LINES HAVE BEEN TESTED, DISINFECTED AND CLEARED FOR USE. �I� 1-1/2" TEE, SCH. 40 DOUBLE STRAP TAPPING 3� CONTRACTOR TO SADDLE W/ CORP. STOP 1-1/2" SWING JOINTS 90' SCH. 40 PVC i CONNECT TO PRIVATE SERVICE WITH NECESSARY COUPLINGS, FITTINGS TWO EACH i AT R/W LINE PLAN VIEW - DOUBLE DOMESTIC SERVICE TES 22 1. FOR WATER SERVICE TO OTHER SIDE, USE SIMILAR METHODS AND MATERIALS.. NO. NO CONNECTION TO EXISTING POTABLE SYSTEM SHALL BE ALLOWED UNTIL ALL NEW WATER LINES HAVE BEEN TESTED, DISINFECTED AND CLEARED FOR USE. M 3� z o � M 0 R/W LINE WATER MAIN PROPERTY LINE SIZE VARIES ROADWAY TO R/W LINE VARIES METER BOX PROVIDED AND INSTALLED BY CONTRACTOR VARIES BORE AND JACK UNDER W/CURB STOP AND METER SEE ~1I PAVED ROADWAY AND CURB 1"x3/4" RED. SPECIFICATIONS AND STANDARDS ROADWAY WIDTH VARIES 1 ------4 iw0.5' TYP. 1" CORPORA fION STOP 5' TYP 5' TYP CONTRACTOR TO 1" SCH. 40 PVC SERVICE PIPING CONNECT TO PRIVATE SERVICE WITH NECESSARY COUPLINGS, FITTINGS 6" MAX 1" SWING JOINTS I AT R/W LINE DOUBLE STRAP TAPPING 90' SCH. 40 PVC i SADDLE W/ CORP. STOP TWO EACH i k DIMENSIONS MAY VARY TO AVOID PLACEMENT OF METERS UNDER DRIVEWAY. PLAN VIEW - SINGLE DOMESTIC SERVICE NOTES 1. FOR WATER SERVICE TO OTHER SIDE, USE SIMILAR METHODS AND MATERIALS. 2. NO CONNECTION TO EXISTING POTABLE SYSTEM SHALL BE ALLOWED UNTIL ALL NEW WATER LINES HAVE BEEN TESTED, DISINFECTED AND CLEARED FOR USE. WATER SERVICE CONNECTION DETAIL N.T.S. CONNECTION TO BE MADE BY CITY OR PLUMBER IF APPRO CURB 1EMENT METER BOX & COVER-) CORPORATION STOP METER 10" MIN. 22.5' WATER SERVICE LINE, LENGTH VARIES UNDISTURBED SOIL SET METER ON UNDISTURBED OR COMPACTED SOIL DISTRIBUTION MAIN LOCATION OF MAIN MAY VARY, ADJUST CONSTRUCTION TO SUIT CONDITIONS. NOTES: 1. METER TO BE LOCATED AS SHOWN IN PLAN VIEW, PLATE NO. 7 2. METER BOXES TO BE PROVIDED & SET BY CONTRACTOR. METER BOXES TO BE DOUBLE WALL PLASTIC w/TOUCH-READ LID. 3. CONNECTION TO BE MADE BY CONTRACTOR OR PLUMBER & MUST BE INSPECTED BY CITY WATER METER DETAIL N.T.S JOHN E. COLLINS, JR PE#40085 WATER MAIN DETAILS IFILE NO I N ✓T cro a __ NN L O N N C) J m M v C JQ) a m w - i� !n o 0 C Q)�u W m O C N () 1n f Y N U Q r m � N � O m UIn � w ro DATE DEC. 2014 SCALE AS SHOWN DRAWN BY JEC DESIGNED BY JEC D-2 5 OF 6 SHEETS SEDIMENT & I. IHE CON -FAC -OR IS RESPONSIBLE FOR PEMO'/ING SILT FROM SITE IF NO kI,USA ELECT SITE AND ASSUkII1G FLAN ADGNMENI AIIU GPADE III ALL DITCHES AND SWALFS Al COMP LEI ION OF CONSTRUC-]ON 2. IHESUE CONIRAC IOP IS RESPOFISIE_E FOR REMOVING IHE IEMPORAR/ EROSION AND SEDIMENT CONTROL DEVICES AFTER COMPLETION OF CONSTRUCIIOH AND ONLY WILD I APEAS HAVE BEEN S-AMIZED. 3 ADDIIONAL PROTECT 1011 -ON -SFE PFO- ECIION IN ADDIIIOH TO THE ABO'JE MUST BE PROVIDED -HAT WILL NOT PERM( SILT TO LEAVEHE PPOJEG CONFINES DUt IO IiNSEEN COPIL:IIIOIIS OF ACCIGEfl IS. 4, CONTRACTOR SHALLNSURE IIIA- ALL DRAINAGE STRUCTURES, HIES, EIC.AkECLEANEDOLIANUWORKINGFROPtELYA IMEOFACCEP ANCE. 5- WIREWESH SHALL BE LAID OVER THE DROP INET SO THAT THE WIRE EXTENDS A MINLMUM GF ' FOOT BEYOND EACH SIDE OF THE INLET STRUC-URE. HAP.DWARECLO-H OR COMPARABLE WIRE .MESH WITH I/2- INCH OPENINGS SHALL BE USED, IF MORE -HAIL GNE STRIP OF MESH IS NECESSARY. THE STRIPS SHALL BE OVERLAPPED. 6. FDOTHO-- COARSE AGGREGFE SHALL BE PLACED OVER THE WIRE MESH AS INDICATED ON SEDIMENT FILTER LE -AIL (SEE DE -AIL -PIIS SHEET). THE DEPTH OF STONE SHALL BE AT LEAS 12,NC- ES O'YEF THE ENTIRE IFU TOPENING. THE STONE SHALL EX-EHD BEIOND-HE II TUE-OPENING AT LEAs 18 INCHES ON ALLS10ES- I. IF IHE SONE FILER BECOMES CLOGGED WITH SEENEIIT SO THAT F NO LONGER ADEQUATELY PERFORMS ITS FUNCIION, THE STONES MUST BE PULLED AWA f FROM TiE INLF-, CLEANED AND REPLACED B. BALES SHALL BE EUHEF HIRE-BOLND OR STRING -TIED WITH TFE BIIICINGS ORIENT -ED AROUND THE SIDES RATHER THAN OVER AND UNDER -HE BALES 9- BALES$HALL BE PLACED LENGTHWISE IN A SINGLE ROW SURROUNCING IHE INLEI WI HI HE ENDS OF ADIACEN BALES PRESSLD TOGETHER. 10. THE FILTER BARRIER SHALL BE EI FPD KITED AND BACKFILLED. A TRENCH SHALL BE EXCAVATED 10 A MINIMUM DEP IT OF 4INCHES. AFTER THE BALES ARE STAKED, THE EYCA'VAIED SOIL SHALL BE BACKFILLED AND COMPAC"ED AGAINST THE FILTEP BAFRIER. I I EACH BALE SHALL BE SECURELY ANCHORED A ND HELD IN PLACE BY AT FAST TWO STAKES OR REEARS DFIVEN THROUGH 111E BALE, 12. LOOSE STRAW SHOLID BE WEDGED BETWEEN BALES TO PREVENT WATER FROM ENTERING BETWELN BALES. 13 STRAW BALE BARRIERS STALL BE INSPECTED INV. F UATELY AFTER EACH RAINFALL AND AT LEAST DAILY DURING FROLONGEDRAINFALL. 14. CLOSE ATTENTION SHA__ BE GIVE\ TO THE REPAIP OF DAMAGED PALFF-S. END RLNS AND UNCERCUTIING BENEATH BALES, TE. PIECESSARY REPAIRS TO BARRIERS OR REPLACEMENT OF BALES SHALL BE ACCOMPLISHED PROMP Lt- 16 SE CIMEN1 DEPOSITS SHOULD BE PEMOVED AF -ER EACH RAINFALL IT M.U$- BE REMOVED W I NEI I TI'.E LE /EL GF DEPOSIHOH REACT IES APPkOXI,MAIELY ONE-HALF IHEHLIGHI OF IPE BARRIER - 1 ]- ANY SECIMENT DEPOSITS REM.AIMIJG ITT PLACE AFTER THE STRAW BALE OR FILLERBARRILRS, AND OR HJI FEkI NCES AFL NO LONGER QI,IREU. SHALL BE DRESSED -O CONFORM 10 HE EXIS-ING GPADE. PFFPAPED AND SEEDED I& SILI FENCES AND HERR BAFFIEPS SHALL BE INSFtCI ED IMMEDILAII:LY AFTER EACH RAINFALL AND AT LEAST DAILY DLRB IG FR OLOIICED RAINFALL, ANY PEQUIRED REPA IRS SH ALL BE MADE IN1NICIATELY. 19 SHOULD THE FABRIC ON A SILT FENCE OR FILTER BARRIER LECCMPOSE OR BECOME IN EFFEC-IVE PRIOR TO THE END OF THE EXPECTED LSABLE I is AND I HE BARRIER STILL BE NLCL' ARY. IHE FAEFIC$HALL BE REPLACED IMMEDIA-ELY. 20. IME S NUCIURE SHALL BE INSFECIED AT ER EACH FAIN AND REPAIRS MADE AS NEEDED. 'I. SEC WENT SHALL BE RE.MO'/ED AND THE IRAF RESTORED TO ITS CRIGINAL DIMENNSIONS WHEN THE SEDIMENT HAS ACCUMULATED TO 1/2 THE DESIGN DEPT H OF -HE TRAP- R EMOV ED SECIMENT SHALL BE DEPOSITED IN A SUFABLE AREA AND IN SUCH A MANLIER _HA- IT WILL NOT EFOLE. 2 IHE CONTRACTOR IS PESPONSI6 E FCR FOLLOWII C, 1HE BEST EROSION AMID SECIMENT CON-FCLPRAC ICES AS OLT_INED II THE FLANS. SPECLFICA-IGNSANDST- JOHIISRIMERWATERMANAGEIIEI! DLSRICT SPEC IFICA'IONS AND CRITERIA 23 FOR ADDITION!AL 1NFCRNIATION ON SEDIMEW AND EROSION CONI ROL REFER TO "THE FLORIDA DEVELOPMENT MANUA_ - A GLIDE TO SOUND LANDAND WATER MANAGEMENT FROM HE STA'E OF FLOkIDA DEPAR-MENT OF E—IROI (MENTA. REGUL4110� IF DER I CHAP -ER 6. 24. EROSION AND SECIMENT CONTROL BARRIERS SHALL BE PLACED ADJACENT 10 AI I WET( AND AREAS WHERE ]HERE IS POIE\IL1I FOR DOWNSTREAM WATEP QUALI'1 DEGRADATION. SEE DETAILS (THIS SHEET)FOR rFICAL COI ISTRLiCTION, 25 SOD$HALL BE PLACED IN AREAS WHICH MAY REOLIRE IM,MECIATE EROTIC' IT PFOIECIICII TO EHSLRE WATER QUART/ STANDARDS ARE MAJFITAIIIED. 26 ANY DISCHARGE FROV DEWATERING ACTIVITY SHALL BE FILTERED AND COLI JEYED-0 THE OUTFALL INA MANNER WFICF PREVENTS EROSION AND IRANSPOR A ION OF SUSPENDED SOLIDS 10 IHE RECEIVING OUIRALL 27.DEWAIERBJGPt,MPSSHAUTIO- EXCEEDTHECAPACIIYOFIFu-wInCH R LQWRES A CONSUMPIME LSE PERM FROM HE SI JOHNS RISER WATEP MANAGEMEII PISIFICT. 25. ALL LIS] Lk BED AREAS SHALL BE GRASSU). HER ILIZEU AND MULCHtD UNTIL A PERMANENT VEGETATIVE COVER IS ESTABLISHED. CONTRACTOR SHALL USEADCIIIONALMEASURES TO S-ABLUE DIS-PUREB AREAS I HROUGH COMPAC ZION. SILT SCREENS. HAY BALLS, AND GRASSING. ALL FILL SLOPES 3'.T OR S'EEPER-0 RECEIVE STAKED SOLID SOD 29. ALL UE WA I tFING. EROSION l AND SEDIP— 11 CON RCL _SHALL REMAIN IFI PLACE UP III AFTER COMPLETION OF CONSIRUC'ION, AND REMOVED CHA Y WHEN AREAS HAVE BEEN I S-AEILIZED, 3C THLSPIAN IIDICATFST IEMINIMUM EROSION AND SEDIMENT IEASLRES REQUIPED FOR IHS PROJEC-. THE CO•NIRACTOR IS kESPONSIBLE FOR WILLING ALL APPLICABLE RULE$. khGLLA IONS AND WATER QUALITY GUIDELINES AND MAY NEED TO INSTALL ADDITIONAL COIL-POLS, 31 THE CON TRACTOR SHALL BE RECTAL ED -0 RESPOND-0ALL WATER MANAGEMEN- 06TRIC- II IQLIP,ES. RELATIVE TO COMPDANCE OF SJRW MD FOR EROSION AND SEDIMEIT A ICN CON FOL THE COSI OF T HIS COMPLIANCE SHALL BE PAF OF THE CONIRAC_ CONTROL NOTES 32. THE CONTRACTOR IS RESPONSIBLE FOR FOLLOWING THE BEST EROSION AND SEDIMENT CONTROL PRACTICES AS OUTLINED IN THE PLANS AND SPECIFICATIONS AND THE ST. JOHNS RIVER WATER MANAGEMENT DISTRICT RULES AND REGULATIONS. 33. EROSION AND SEDIMENT CONTROL BARRIERS SHALL BE PLACED ADJACENT TO ALL WETLAND AREAS AND PRESERVATION EASEMENTS WHERE THERE IS POTENTIAL FOR DOWNSTREAM WATER QUALITY DEGRADATION. 34. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ESTABLISHING A PERMANENT STAND OF SOD AND/OR GRASS PER THE CONTRACT DOCUMENTS THE ST. JOHNS RIVER WATER MANAGEMENT DISTRICT AND DUVAL COUNTY STANDARDS AND MEETING THE NPOES FINAL STABILIZATION REQUIREMENTS. 35. THESE PLANS INCLUDING THE POLLUTION PREVENTION PLAN INDICATE THE MINIMUM EROSION & SEDIMENT CONTROL MEASURES REQUIRED FOR THIS PROJECT. FOR ADDITIONAL INFORMATION ON SEDIMENT AND EROSION CONTROL REFER TO "THE FLORIDA DEVELOPMENT MANUAL - A GUIDE TO SOUND LAND AND WATER MANAGEMENT" FROM THE STATE OF FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION (F.D.E.P.) CHAPTER 6. CONTRACTOR SHALL PROVIDE EROSION PROTECTION AND TURBIDITY CONTROL AS REQUIRED TO INSURE CONFORMANCE TO STATE AND FEDERAL WATER QUALITY STANDARDS AND MAY NEED TO INSTALL ADDITIONAL CONTROLS TO CONFORM TO AGENCIES REQUIREMENTS. IF A WATER QUALITY VIOLATION OCCURS, THE CONTRACTOR SHALL BE WHOLLY RESPONSIBLE FOR ALL DAMAGE AND ALL COSTS WHICH MAY RESULT INCLUDING LEGAL FEES, CONSULTANT FEES, CONSTRUCTION COSTS, AND FINES. 36, 48 HOURS PRIOR TO COMMENCEMENT OF CONSTRUCTION, THE CONTRACTOR WILL SUBMIT A "NOTICEOF INTENT" TO THE EPA IN ACCORDANCE WITH NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM RULES AND REGULATIONS. (FOR ANY CONSTRUCTION NOT COVERED BY THE OWNER'S "NOTICE OF INTENT" PERMIT) SEDIMENT/HYDROCARBON ABSORBENT BARRIER. INSTALL COMPLETELY AROUND PERIPHERY OF II ENVIRONMENTAL SGUTTERBL EXIST SPECIFIC APPLICATION THIS METHOD APPLICABLE TO ALL INLETS LOCATED WITHIN PAVED AREAS. INLET FIL TER FABRIC SEDIMENT FIL TER NOT TO SCALE 1',' AlJD EXGAVAT= .i x T_;_r; II- ,L'iF E AL"� C TI~E jr,,[ -j 14" LTER FABRIC BETWEEN GRATING AND ALL INLETS WITHIN LIMITS OF WORK STORM INLET GRATING (TYP) r—T�• I r - II r I s "IC TO T -IE 'AIRF T TI iL E L , -ir L T II''dT i TH1- TRFf CH CONS TRUC TION OF SIL T FENCE EROSION AND SEDIMENT CONTROL DETAILS 11 D-3