379 10th St 2015 HVAC CITY OF ATLANTIC BEACH i� 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 MECHANICAL HVAC PERMIT MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 15-MECH-350 Job Type: MECHANICAL HVAC ONLY Description: 3 tons, 34K BTU'S Estimated Value: Issue Date: 2/17/2015 Expiration Date: 8/16/2015 PROPERTY ADDRESS: Address: 379 10TH ST RE Number: 170090-0010 PROPERTY OWNER: Name: FARBER, RHETT Address: 1528 REPUBLIC DR GENERAL CONTRACTOR INFORMATION: Name: DONOVAN HEATING & AIR Address: 315 SIXTH AVENUE S QA WILLIAM J DONOVAN Phone: - - PERMIT INFORMATION: Sticker for overcurrent protection must be on A/C equipment prior to inspection. Failure to comply will result in a failed inspection and reinspect fees. No exceptions. FEES: Furnaces and Heating $20.00 AC and Refrigeration $24.00 State Mech DBPR Surcharge $2.00 State Mech DCA Surcharge $2.00 Trade Permit Base Fee $55.00 Total Payments: $103.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax (904) 247-5845 (OB ADDRESS: 3-71! P) f k S+ PERMIT# PROJECT VAL UE $ C)H q a %c) ARI# <Q 5 S9 ' REQUIRED Air Handling Equipment Only �( Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity I — Tons Per Unit 3 'S Heat: Unit Quantity ► BTU's Per Unit 3H G-13 Seer Rating Duct Systems: Total CFM Ja4d REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating REQUIRED Duct Systems: Total CFM FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solar Collection Systems Tanks (gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months. I hereby certify that I have read Tis application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name ke,f4- fns bar Phone Number L�xcw c� �c�+ �- A1�� Office Phoney(- S�Fax )1-374 Mechanical Company 5 Co. Address: 3 ( S Lam, A�tQ S {lti Citi &oc� State Zip311'6) License Holder (Print): _ �.J,, 1 L a� ^����� State Certification/Registration#�q7 Notari—d.Vamyt,.rp of L icense Holder ^ Before me this 17 day oft— 20 15 ;�.s'Aya,•., RICHARD TOMPKINS - ,.. Commission#FF 040399 Expires July 29,2017 ;i nature of Notary Public Booded Thm Troy N�Insurance 600-9 4011 g Job: wrigh soft Project SUMMM Hate: MV114 Entire House By: Brandon zaharie Donovan Heat& Air 31S 6th avo south,Jacksonville Beach,FL 32750 Phone:241-3785 Emall: bMndonLMdonovnnac com For: Farber 379 10 th ST,ATLANTIC BEACH, FL 32233 Notes: Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 OF Outside db o inside db 68 OF Inside db 20 'F Design TO 29 "F Design TD L Daily range 50 Relative humidity 53 gr/lb Moisture difference g Heating Summary Sensible Cooling Equipment Load Sizing 17610 Btuh Structure 16031 Btuh Structure 5848 Btuh Ducts 8534 Btuh Ducts997 Btuh Central vent (31 cfm) 688 Btuh Central vent (31 cfm) Blower 0 Btuh Humidification 0 Btuh Piping 0 Btuhs data n Equipment load 24454 l3tuh Use manufacturer1.00 Rate/swing multiplier Infiltration Equipment sensible load 25253 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average 2067 Btuh Fireplaces 1 (Average) Structure 1891 Btuh Ducts 1132 Btuh Heating Cooling Central vent (31 cfm) 5090 Btuh Area {ftz 1720 1720 Equipment latent load volume�ft') 15480 15480 0. Equipment total load 30343 Btuh Air changes/hour 0.46 152 Req, total capacity at 0.70 SHR 3.0 ton Equiv.A17F (cfm) ry Cooling Equipment Summary Heating Equipment Summa Make TEMPSTAR Make TEMPSTAR Trade Trade Model NXH536 CoX 4X ARI ref no. 6955268 Coil l FXM ARI ref no. 695526868 15 SEER Efficiency 8,5 HSPF Efficiency 25253 Stuh 47°F Heating input Sensible cooling 1Q823 Stuh Heating output 35896 Btuh @ Latent cooling 36076 Btuh 27 OF Total Cooling12p3 cfm Temperature rise 1203 cfm Actual air fow 0.049 cfm/Btuh Actual air flow 0,051 cfm/Btuh Air flow factor Air flow factor 0 in H2O Static pressure 0 in H2O Static pressure Load sensible heat ratio 0.83 Space thermostat Printout certified by ACCA to meet all requirements of Manual J 8th Ed. 2015-Feb•12 1508:22 wright�o�k' Rlght-Sultefo Universal 7.1,01 RW05996 Page 1 J [s c:lUserslsalo?IDccumentak gh"et HVAC13 Ton,rup Gn1c�MJa oriontntlon N