Loading...
152 3rd St 2015 addition remodel permit CITY OF ATLANTIC BEACH r� 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 � C RESIDENTIAL ADDITION MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 ]OB INFORMATION: ]Ob ID: 15-RADD-313 Job Type: RESIDENTIAL ADDITION Description: remodel /addition Estimated Value: $300,000.00 Issue Date: 3/13/2015 Expiration Date: 9/9/2015 PROPERTY ADDRESS: Address: 152 3RD ST RE Number: 170196-0000 PROPERTY OWNER: Name: ANDO, STEPHANIE ELIZABETH Address: 152 3RD ST GENERAL CONTRACTOR INFORMATION: Name: BOSCO BUILDING CONTRACTORS Address: 2158 MAYPORT RD QA TODD ALBERT BOSCO Phone: - - PERMIT INFORMATION: PUBLIC WORKS: Any utility cuts in the road must be repaired using COJ Standard Detail Case X and must be overlaid 10 feet in each direction from the center of the cut. Repair must be shown on the plans. Full right-of-way restoration, including sod, is required. Roll off container company must be on City approved list and container cannot be placed on City Right-of-Way. (Approved: Advanced Disposal, Realco, Republic Services, Shappel's and Waste Pro.) Full erosion control measures must be installed and approved prior to beginning any earth disturbing activities. Contact Public Works (247-5834) for Erosion and Sediment Control Inspection prior to start of construction. This approval is based on revised drawings submitted in response to comments dated 2/20. (Drawing revision not shown (impervious pre 53.52%, post 38.49%)). If any portion of the non-conforming wall is modified the entire wall is to be removed and right-of-way fully restored. PE it IS APPIZ i ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. r `f CITY OF ATLANTIC BEACH s� 800 SEMINOLE ROAD J '~ ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 'V�Jftl�f' **This resubmittal deletes the need for previously disapproved driveway permit 15-DWAY- 314** FEES: ENG REV RESIDENTIAL BLD $100.00 PLAN CHECK FEES $540.00 UTIL REV RESIDENTIAL BLDG $50.00 BUILDING PERMIT FEE $1,080.00 STATE DCA SURCHARGE $16.20 STATE DBPR SURCHARGE $16.20 Total Payments: $1,802.40 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. ► 'L`I js1 CITY OF ATLANTIC BEACH r } 800 SEMINOLE ROAD �J "N ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 r� Jl)19�- " DRIVEWAY PERMIT MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 15-DWAY-314 Job Type: DRIVEWAY Description: driveway for addition Estimated Value: Issue Date: 3/13/2015 Expiration Date: 9/9/2015 PROPERTY ADDRESS: Address: 152 3RD ST RE Number: 170196-0000 PROPERTY OWNER: Name: ANDD, STEPHANIE ELIZABETH Address: 152 3RD ST GENERAL CONTRACTOR INFORMATION: Name: BOSCO BUILDING CONTRACTORS Address: 2158 MAYPORT RD QA TODD ALBERT BOSCO Phone: - - PERMIT INFORMATION: UTILITY DEPT.: Ensure all meter boxes, sewer cleanouts and valve covers are set to grade and visible. A sewer cleanout must be installed at the property line. Cleanout must be covered with an RT1 concrete box with metal lid. Cleanout to be set to grade and visible. FEES: Fence/ROW $35.00 Total Payments: $35.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. CITY OF ATLANTIC BEACH CONSTRUCTION PERMIT WITHIN CITY RIGHTS OF WAY AND EASEMENTS 800 Seminole Road 904-247-5800 Atlantic Beach,Florida 32233-5445 Fax 904-247-5845 PLEASE SUBMIT(3)COMPLETE SETS OF PLANS WITH APPLICATION. Date February 6th,2015 - PERMIT tt Job Address Jr S4-Atlantic Beach, FL 32233 ISSUED BY THE CITY Permitee: Katherine Allison Hillis Telephone# 904-241-0320 Permittee Address: _380 5th Street Atlantic Beach, FL 32233 Requesting Permission to Construct: Driveway with concrete pavers Location: (Reference to Cross-Street) Beach Ave and 3rd Street 1 Applicant declares that prior to filing this application he has ascertained the location of all existing utilities, both aerial and underground and the accurate locations are shown on the sketches. A Letter of Notification was mailed to the following Utilities/Municipalities: Jacksonville Electric Authority Yes(,/) No ( ) Date: 2/6/15 Bell Sou p e enrigany Yes(�/) No ( ) Date: 2/6/15 Ferrellupy Yes(�/) No ( ) Date: 2/6/15 Comcas I L Yes No ( ) Date: 2/6/15 2. Whenever necessary for the construction, repair, improvement, maintenance, safe and efficient operation, alteration or relocation of all, or any portion of said street or easement as determined by the Director of Public Works, any or all of said poles, wires, pipes, cables or other facilities and appurtenances authorized hereunder, shall be immediately removed from said street or easement or reset or relocated hereon as required by the Director of Public Works, and at the expense of the Permittee unless reimbursement is authorized. 3. All work shall meet City of Atlantic Beach or Florida Department of Transportation Standards and be performed under the supervision of Todd Bosco (Contractor's Project Superintendent)located at 2158 Mayport Rd Atlantic Beach FL Telephone#: 904-241-0320 4. All materials and equipment shall be subject to inspection by the Director of Public Works or his designee. 5. All city property shall be restored to its original condition as far as practical, in keeping with city specifications and the manner satisfactory to the city. A sketch of plans covering details of this installation, as well as, a copy of a recent survey shall be made a part of this permit. Calculations showing any increase in impervious area on owner's lot or in the citv Right of Way are to be included with this application 7. This permittee shall commence actual construction in good faith with days. If the beginning date is more than 60 days from date of permit approval, then permittee must review the permit with the Director of Public Works to make sure no changes have occurred in the area that would affect the permitted construction. 8 It is understood and agreed that the rights and privileges herein set out are granted only to the extent of the City's right, title and interest in the land to be entered upon and used by the holder, and the Holder will, at all times, assume all risk of and indemnify, defend, and save harmless the City of Atlantic Beach from and against any and all loss, damage, and cost of expenses arising in any manner of the exercise or attempted exercises by the holder of the aforesaid rights and privileges. 9. The Director of Public Works shall be notified twenty-four (24) hours prior to starting work and again immediately upon completion. OWNER WILLIAM L.POPE _ Notary Public,State of Florida Signed: Date: / '�� My Comm.Expires Oct.19,2015 Before me this - day of 6:Gwa in the County of Duval, Commission No.EE 128745 State Of Florida,has personally appeared C r -eli VA /F• /h J Notary Public at Large,State of Florida,County of Duval _ My commission expires:_ !_eL:;nally Known: . Produced Identification R.O.W. Permit Attachment of for 296 Beach Ave R.O.W. Permit# issued , 200_ Atlantic Beach, FL 32233 Owner's Name: Katherine Allison Hillis Property Address: 1 Atlantic Beach,FL 32233 Subdivision: 03101 ATLANTIC BEACH Lot#/Block#: LOT 6 BLOCK 28 R.E. #: 5-69 16-2S-29E.15 REVOCABLE ENCROACHMENT PERMIT THIS REVOCABLE ENCROACHMENT PERMIT, issued on this 6th day of February , 2015, by Atlantic Beach, Florida, a municipal corporation organized and existing under the laws of the State of Florida, hereinafter referred to as "CITY" and Katherine Allison Hillis of Atlantic Beach, Florida, hereinafter referred to as "USER". WITNESSETH: That the CITY does hereby grant the USER permission on a revocable basis as described herein the right to enter upon the property of the City of Atlantic Beach for the purpose as described in the City of Atlantic Beach Right-of-Way/Easement permit numbers noted above(copies attached). This work is generally described as: Any facility maintained, repaired, erected, and/or installed in the exercise of the privilege granted remains subject to relocation or removal on thirty (30) days notice by CITY to the USER, said notice to USER shall be given by certified mail, return receipt requested, to the following address: 296 Beach Ave Atlantic Beach, FL 32233 The depositing of said notice of cancellation in the United States mail shall constitute the notice of cancellation and the burden is upon USER to keep the CITY informed of USER's proper address. The USER shall promptly make any and all necessary repairs to any facility erected or maintained in the exercise of the privilege herein granted and shall at all times maintain said facility in good and safe condition. In the event it is necessary for the CITY or the City's approved representative or other franchised utility to enter upon the above-described property of the CITY, the USER shall replace at the USER's sole expense, any and all material necessarily displaced during the action of maintaining, repairing, operating, replacing, or adding to of the utilities and facilities of the CITY or franchise utility provider. The facilities allowed by the permit shall meet the current requirements of the City Code, Building Codes, Land Development Code, and all other land use and code requirements of the CITY, including City Code Section 19-7 (h) which states "Driveways that cross sidewalks: City sidewalks may not be replaced with other materials, but must be replaced with smooth concrete left natural in color so that it matches the existing and adjoining sidewalks." Pagel of 2 The USER, prior to making any changes from the approved plans and/or method, must obtain written approval from the City of Atlantic Beach, Public Works Department, for said change. The USER shall, at the discretion of the CITY, be requested to submit as-built drawings showing the change within thirty(30) days after the day of completion. This permit shall insure to the benefit of, and be binding upon, the USER and their respective successors and assigns. USER shall meet the terms and conditions of this permit and to all of the applicable State and CITY laws and/or specifications, to include utilities locate requirements and use limitations/requirements of public rights-of-way and other public land. USER further agrees that the CITY and its officers and employees shall be saved harmless by the USER from any of the work herein under the terms of this permit and that all of said liabilities are hereby assumed by the USER. DATED and SIGNED this 6 day of l , 201-s- By: V4&z�A;�b P operty Owner (to be signed in presence of the Notary) STATE OF FLORIDA COUNTY OF DUVAL On this day of 200�,_personally appeared before me, a Notary Public in and for said County"'and State, K'd7 y-Rlve R-H-,Il,'S' the property owner of >y6 /3 6Ace-1 '411C , Atlantic Beach, Florida, known to me to be the person(s) described in and who executed the foregoing instrument; who acknowledged to me that he or she executed the same freely and voluntarily and for the uses and purposes therein mentioned. J� , WILLIAM L.POPE Notary Public,State of Florida Notary Public in for said County and State My Comm.Expires Oct.19,20-15 Gommission No.EE 128745 CITY OF ATLANTIC BEACH, FLORIDA, a municipal corporation: Approved: Ricky L. Carper, Public Works Director For Permits where city sidewalk is impacted, City Manager approval required: Jim Hanson, City Manager Page 2 of 2 ,.� City of Atlantic Beach A' Building Department APPLICATION NUMBER y � 800 Seminole Road I RECEIVED (To be assigned by the Building Department.) Atlantic Beach, Florida 32233-5445 ! _ Phone(904) 247-5826 Fax(904 2 47-584 /� �� E-mail: building-dept@coab.us ) IE� 1 1 �Q��J City web-site: http://www.coab.us 1 Date routed: APPLICATION REVIEW AND TRACKING FORM Property Address: ��Z 4ra S7- Department review required Yes No Building Applicant: S Planning&Zoning Tree Administrator Project: V�l,Ji9 ublic o 6AI ,c Pub is afety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Verified By Date Florida Dept. of Environmental Protection of Permit Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. Denied. (Circle one.) Comments: BUILDING �t£ , . _44£D PLANNING&ZONING Reviewed by: Date: TREE ADMIN. Second Review: ❑Approved as revised. [E]Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: DApproved as revised. DDenied. Comments: Reviewed by: Date: Revised 07/27/10 City of Atlantic Beach APPLICATION NUMBER Building Department RICEIVE 800 Seminole Road (To be assigned by the /Building Department.) Atlantic Beach, Florida 32233-5445 �A - �/y Phone(904)247-5826 Fax(904)247- 845 FEB 1 1 2015 '!a;W), E-mail building-dept@coab.us ' Date routed: City web-site: http://www.coab.us 8457L APPLICATION REVIEW AND TRACKING FORM Property Address: 15Z .3;-Q S7— Department review required Yes No ZBuilding Applicant: o-5 d Planning &Zoning Tree Administrator Project: ublic o 61VPublic Safety 61V I Fire Services _(_AA (AA Review fee Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Arm Corps Army p of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco L.Other: APPLICATION STATUS Reviewing Department First Review: OApproved. [—]Denied. (Circle one.) Comments: BUILDING PLANNING &ZONING � � _ 2- 1 Reviewed by: ""+ Date: 115— TREEADMIN.. Second Review: ❑Approved as revised. ❑Denied. 4CCBLL C WORK Comments: UTILITIES Z-/ 2!-13--- PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 07/27/10 ip �� r ✓J�. -CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC B FILE COPYEACH,FL 32233 s:�J131�f� % .�.,, (904) 247-5800 Revision Request Sheet Date: /S Received by: Resubmitted: Permumb it Ner: Clearance Sheet Number: Imo[ Original Plans Examiner: Project Name: Project Address: /-SL Contractor:�G,ICOFj �'D�✓ Q d act Name: Contact Phone Number: /�/ Z��— O3Zv Contact Fax Number: Revision/plan Check/Permit Fee(s)Due: $ Description of Proposed Revision to Existing Permit Pending Hold: Structural: Plumbing: Mechanical: Electrical: i Additional Increase in Building Value: $ Additional Square Footage: Clearance Sheet/Site Plan Revised: B signing below,X Environmental Health Approval: BY g g 7 (Print n,me) �J4 fQ �a.Jl a proposed changes. affirm that the above revision is inclusive of the c���d7y 7 Signature of Contractor/A ent g (Contractor must sign if increase in valuation) Date Date: Office Use Only ,�'$��o1p S Approved: Rejected: Notified by:_ Plan Review Comments: Plans Created osiosios.jio — Date a FILE C101 .4 Y .i"Sr CITY OF ATLANTIC BEACH ,J 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 �!r (904) 247-5800 Date: 31r I Received by: Revision Request Sheet // Resubmitted: Permit Number: Clearance Sheet Number: Ir.[ Original Plans Examiner: ) Project Address: Project Nam �e Contractor: r t ! ice ^c Contact Name: T Contact Phone Number: _ `! - G a0 Contact Fax Number: Revision/Plan Check/Permit Fee(s)Due:$ Descrintion of Proposed Revision to Existing Permit Pending Hold: Structural: e r Plumbing: Mechanical: 4 Electrical: Misc.: sir n„ Additional Increase in Building Value: $ Clearance Sheet/Site Plan Revi ed: Additional Square Footage: 7 Environmental Health Approval:_______ By signing below,Y(print name) proposed chan es. affirm that the above revision is inclusive of the Sign re of C t(Contractor must sign if increase in valuation) Dater Date: Office Use Only �' � � � Approved: Rejected: Notified by: Plan Review Comments: Plans Ex er — �• _ l' S _.______��.�_, Created OS/OS/08.j10 Date _ �S ei °I'I'Y OF ATLANTIC BEACH J � 800 SEMINOLE ROAD FILE C ATLANTIC BEACH,FL 32233 (904) 247-5800 Revision Request Date: 2 �CA 1� Received blz�y- Resubmitted: Permit Number: Clearance Sheet Number: ' Original Plans Examiner: Project Name: Project Address: Contractor: Contact Name: Contact Phone Number: Contact Fax Number: Revision/plan Check/Permit Fee(s)Due: $ Description of Proposed Revision to Existing Permit Pending Hold: J�R0 '4E') 20 Structural: : Plumbing: Mechanical: Electrical: Misc.: I;: M k9vS 1 1'4 CT♦lf 72i- P pd2t"&L Additional Increase in Building Value: $ Additional Square Footage: Clearance Sheet/Site Plan Revised: Environmental Health Approval: affirm By signing below,I Ar; , , proposed change affirm that the above revision is inclusive of the 11,11" ign a of Contractor/Agent(Contractor must sign if increase in valuation) Date Office Use Only Date: �'��^ Approved: C Rejected: Notified by: Plan Review Comments: l D� rC/►y` �c // // Plns E iner 2 '.2 5'''/ Created 08/05/08 jlo Date "Madsa�a+MWv..a.xV BUILDING PERMIT APPLICATION ' ` 3 CITY OF ATLANTIC BEACH AdO3 DIP g r � FILE C Seminole Road,Atlantic Beach, FL 32233 � `'L"�• �.�� ;�. Office(904)247-5826 Fax (904)247-5845 Job Address: SZ 120 sT Atlantic Beach,FL 32233 Permit Number: Legal Description 5-69 16-2S-29E.15 03101 Atlantic Beach Parcel# LOT 6 BLK 28 Atlantic Beach Plo�a�� OOOr Proposed Area o q, t. t Valuation of Work $ Pro osed Work heated/cooled non-heated/cooled Class of Work(circle one): New Addition Alteration Repair Move Demolition pool/spa window/door Use of existing/proposed structure(s)(circle one): Commercial Res' If an existing structure,is a fire sprinkler system installed?(Circle one): es o Florida Product Approval# For multiple products use product approval form Describe in detail the type of work to be performed:_ ��D�- Q 0 L Property Owner Information: Name: Katherine Allison Hillis Address: 380 5th Street City Atlantic Beach State FL Zip 32233 Phone 904-813-1577 E-Mail or Fax#(Optional) Contractor Information: Company Name: Bosco Building Contractors Inc Qualifying Agent: Todd A. Bosco Address:2158 Mayport Rd City Atlantic Beach State FL Zip 32233 Office Phone 904-241-0320 Job Site/Contact Number 904-241-0320 Fax# 904-241-0326 State Certification/Registration# CBC 1250212 Architect Name&Phone# Engineer's Name&Phone# Fee Simple Title Holder Name and Address Bonding Company Name and Address Mortgage Lender Name and Address Application is hereby made to obtain a permit to do the work and installations as indicated. I cert that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet the standards ojall laws regulating construction in this jurisdiction. This permit becomes null and void tf work is not commenced within six(6)months,or if construction or work is suspended or abandoned for a penod of six(6)months at anytime after work is commenced. I understand that separate permits must be secured for Electrical Work,Plumbing,Signs, Wells,Pools, Furnaces, Boilers,Heaters, Tanks and Air Conditioners,etc. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. I herebycertify that I have read and examined this application and know the same to be true and correct. All provisions of laws and ordinances governing this type of ork will be complied with whether specified herein or not. The granting of a permit does not presume to give authority to violate or cancel the provisions of any other federal,state,or local law regulating construction or the performance of construction. tAySignature of Owner Signature of Contractor Print Name .K� 1.Y '...T).r!N.�7!(�(1..........f.� 1.�,t........................... Print Name .Todd A. Bosco Sworn,to and subscribed before me Sworn to and subscribed be ore me � this —Day of 20 /S' this OT Day of >cL 201 K- WILLIAM t,pupt: Notary Public Notary Public, WILLIAM L.FUPE­_ State of Florida Notary Public Notary Public,State of Florida My Comm,Expires Oct.19,2015 p$�, sOClct.19,2015 Commission No.EE 128745 Commission No.EE 128745 DO NOT WRITE BELOW- OFFICE USE ONLY App icE Fe—Co es: 2I FLORIDA BUILDING CODE Review Result (circle one): Approved Disapproved Approved w/ Conditions Review Initials/Date: Development Size Habitable Space 76T s- 4^ Non-Habitable Impervious area Miscellaneous Information Occupancy Group �- 3 Type of Construction Number of Stories Zoning District /2 S Max. Occupancy Load Fire Sprinklers Required Flood Zone lq Conditions/Comments: Cd > D p p 00 --1 O, fD .� fD N A CDZD CD CD d eD CD O CDt x � d o CD w y 00 r) > `b ov cn a �* 0 0 w oo, o rb 0 o Q- cs o wC3 e � z 0 TI o N C7 cn %h �, •ti CD R w y � � o a r= �• < O G o d o � dCfQ A o ° = CD o �c PTI O CD W CD o �D � o ►C o CD C OTI O -ti Qn o � a r: Y 77 (j- � b y Uri Ur, crn -r C A 00 C" CD V1 Com" 43 O ,,sMcr CD a r� CD o Cr 1 'T� C / S 7 n / S o n o 0 0 § o o = * o w o o d % 7 0 6 y i G n ƒ \ o f \ m ± q _ -• \ = 2 ƒ / q / o & o CLn * 8' / k o ° \ � \ 0- m § o ƒ * 7 o E $ § z e n j \ g ƒ GQ ƒ ƒ E ƒ \ E ƒ / z ? § ° ) * « 5 9 0 { 2 CD _ n � / & � _ � * f m a 0 ° _ n ti 2 � 7 . � [ k � ■ & r K / / / / 4t Q Q r / # m * C 0a = & / k 2. 7 ? f 2 + ° ƒ 5 \ ƒ R j \ co § \ 2 7 ® ƒ � � � _ � J \ � k _ a c k � E � k / _ % � n � f m # � # :? CD N CrJ Z A N CD n W cr El CD rD Atv N td o p — R.^� b pop n ^ R. n �* A� Q 0 > OQ d CCD �p O Cl. O (D O rP � C1, gin' � �. �• 7' l� a <D p �• O� '� �• ��-n -cs CD CD � o o CD ?? " `� o ° CD c c eD CD o eD � n A <DCL Q- C ° a o C W vn CAD ' C -, 11 w ' O w r+ O CDD CDCD O � . ° ° a o c CL COAD CL c o' (D ¢ W C' c c� FILE COPY FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Hillis 152 3rd St Atlantic Beach Builder Name: Bosco Custom Homes Street: 152 3rd Street Permit Office: Duval City,State,Zip: Atlantic Beach,FL,32233- Permit Number: Owner: Jurisdiction: 261100 Design Location: FL,Jacksonville 1 New construction or existing New(From Plans) 9. Wall Types(3080.3 sgft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=13.0 3080.30 ft2 b.N/A R= ft2 3. Number of units,if multiple family 1 c. N/A R= ft2 4 Number of Bedrooms 3 d.N/A R_ ft2 5. Is this a worst case? No 10.Ceiling Types (1412.0 sgft.) Insulation Area a.Under Attic(Vented) R=30.0 1412.00 ft2 6. Conditioned floor area above grade(ft2) 3317 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c. N/A R= ftz 11.Ducts R ft2 7. Windows(916.9 sgft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 165 a. U-Factor: Dbl,U=0.35 916.90 ft2 b.Sup: Attic,Ret:Main,AH:Upstairs 6 165 SHGC: SHGC=0.35 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 29.8 SEER:13.00 c. U-Factor: N/A ft2 b.Central Unit 34.0 SEER:13.00 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 29.8 HSPF:7.70 SHGC: b.Electric Heat Pump 34.0 HSPF:7.70 Area Weighted Average Overhang Depth: 2.990 ft. Area Weighted Average SHGC: 0.350 14.Hot water systems 8. Floor Types (2782.0 sgft.) Insulation Area a.Natural Gas Tankless Cap:1 gallons a.Slab-On-Grade Edge Insulation R=0.0 1412.00 ft2 b. Conservation features EF:0.750 b.Floor Over Other Space R=0.0 1370.00 ft2 None c. N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.276 Total Proposed Modified Loads: 49.33 PASS Total Standard Reference Loads: 63.84 1 hereby certify that the plans and specifications covered by Review of the plans and O4-vHE STAT this calculation are in compliance with the Florida Energy specifications covered by this Code. tie�)eervic,� calculation indicates compliance-- with the Florida Energy Code.PREPARED BY: �eBefore construction is completed DATE: 1/20/2015 this building will be inspected for compliance with Section 553.908 +° • tr I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. I�COD WF OWNER/AGENT: BUILDING OFFICIAL: DATE: -._ DATE: ` oZ0/ 5 - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist 1/20/2015 4:35 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6 PROJECT Title: Hillis 152 3rd St Atlantic Beach Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 3317 Lot# Owner: Total Stories: 3 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Bosco Custom Homes Rotate Angle: 0 Street: 152 3rd Street Permit Office: Duval Cross Ventilation: County: Duval Jurisdiction: 261100 Whole House Fan: City,State,Zip: Atlantic Beach, Family Type: Single-family FL, 32233- New/Existing: New(From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp IV/ Design Location TMY Site Zone 97.5% 2,5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL—JACKSONVILLE—INT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Block1 1412 14120 2 Block2 1905 17145 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1412 14120 Yes 4 0 1 Yes Yes Yes 2 Upstairs 1905 17145 No 0 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 155 ft 0 1412 ft2 ____ 0.3 0 0.7 2 Floor Over Other Space Upstairs ---- ---_ 1370 ft2 0 0 0 1 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 1579 ft2 0 ft2 Light 0.96 No 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1412 ft2 N N 1/20/2015 4:35 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6 CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic(Vented) Upstairs 30 1412 ft2 0.11 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below _Ornt moo _ WallTypp ______ Space 13-Value Ft In Ft In__ area -R--Vatue--Fraction. Absor-_Grade% 1 N Exterior Frame-Wood Main 13 5 0 10 0 50.0 ft2 0 0.23 0.8 0 2 S Exterior Frame-Wood Main 13 15 0 9 0 135.0 ft2 0 0.23 0.8 0 3 W Exterior Frame-Wood Main 13 27.5 0 9 0 247.5 ft2 0 0.23 0.8 0 4 N Exterior Frame-Wood Main 13 15 0 9 0 135.0 ft2 0 0.23 0.8 0 5 N Exterior Frame-Wood Main 13 10 0 10 0 100.0 ft2 0 0.23 0.8 0 6 E Exterior Frame-Wood Main 13 2 0 10 0 20.0 ft2 0 0.23 0.8 0 7 S Exterior Frame-Wood Main 13 16.5 0 10 0 165.0 ft2 0 0.23 0.8 0 8 N Exterior Frame-Wood Main 13 18 0 10 0 180.0 ft2 0 0.23 0.8 0 9 E Exterior Frame-Wood Main 13 15 0 10 0 150.0 ft2 0 0.23 0.8 0 10 E Exterior Frame-Wood Main 13 12 0 10 0 120.0 ft2 0 0.23 0.8 0 11 S Exterior Frame-Wood Main 13 18 0 10 0 180.0 ft2 0 0,23 0.8 0 12 W Exterior Frame-Wood Upstairs 13 14 0 9 0 126.0 ft2 0 0.23 0.8 0 13 N Exterior Frame-Wood Upstairs 13 9 0 9 0 81.0 ft2 0 0.23 0.8 0 14 N Exterior Frame-Wood Upstairs 13 13 0 9 0 117.0 ft2 0 0.23 0.8 0 15 N Exterior Frame-Wood Upstairs 13 11 0 9 0 99.0 ft2 0 0.23 0.8 0 16 E Exterior Frame-Wood Upstairs 13 2 0 9 0 18.0 ft2 0 0.23 0.8 0 17 S Exterior Frame-Wood Upstairs 13 5 0 9 0 45.0 ft2 0 0.23 0.8 0 18 S Exterior Frame-Wood Upstairs 13 13 0 9 0 117.0 ft2 0 0.23 0.8 0 19 S Exterior Frame-Wood Upstairs 13 9 0 9 0 81.0 ft2 0 0.23 0.8 0 20 W Exterior Frame-Wood Upstairs 13 14 0 9 0 126.0 ft2 0 0.23 0.8 0 _21 N Exterior Frame-Wood Upstairs 13 7.7 0 9 0 69.3 ft2 0 0.23 0.8 0 _22 E Exterior Frame-Wood Upstairs 13 14 0 9 0 126.0 ft2 0 0.23 0.8 0 _23 N Exterior Frame-Wood Upstairs 13 10.5 0 9 0 94.5 ft2 0 0.23 0.8 0 24 E Exterior Frame-Wood Upstairs 13 5.5 0 9 0 49.5 ft2 0 0.23 0.8 0 25 E Exterior Frame-Wood Upstairs 13 7.5 0 9 0 67.5 ft2 0 0.23 0.8 0 _26 S Exterior Frame-Wood Upstairs 13 18 0 9 0 162.0 ft2 0 0.23 0.8 0 _27 S Exterior Frame-Wood Upstairs 13 5 0 9 0 45.0 ft2 0 0.23 0.8 0 _28 N Exterior Frame-Wood Upstairs 13 15 0 6 0 90.0 ft2 0 0.23 0.8 0 _29 W Exterior Frame-Wood Upstairs 13 14 0 6 0 84.0 ft2 0 0.23 0.8 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Wood Main None .46 .1 .1 .0 ft2 1/20/2015 4:35 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 0.35 0.35 24.0 ft2 1 ft 0 in 1 ft 0 in None None 2 S 2 Vinyl Low-E Double Yes 0.35 0.35 37.8 ft2 1 ft 0 in 10 ft 0 in None None 3 W 3 Vinyl Low-E Double Yes 0.35 0.35 53.3 ft2 1 ft 0 in 10 ft 0 in None None 4 W 3 Vinyl Low-E Double Yes 0.35 0.35 37.8 ft2 1 ft 0 in 10 ft 0 in None None 5 N 4 Vinyl Low-E Double Yes 0.35 0.35 26.7 ft2 1 ft 0 in 10 ft 0 in None None 6 S 7 Vinyl Low-E Double Yes 0.35 0.35 91.0 ft2 1 ft 0 in 10 ft 0 in None None 7 N 8 Vinyl Low-E Double Yes 0.35 0.35 29.6 ft2 1 ft 0 in 10 ft 0 in None None 8 E 9 Vinyl Low-E Double Yes 0.35 0.35 37.3 ft2 12 ft 0 in 1 ft 0 in None None 9 E 9 Vinyl Low-E Double Yes 0.35 0.35 21.0 ft2 12 ft 0 in 1 ft 0 in None None 10 E 10 Vinyl Low-E Double Yes 0.35 0.35 37.3 ft2 12 ft 0 in 1 ft 0 in None None 11 E 10 Vinyl Low-E Double Yes 0.35 0.35 42.0 ft2 12 ft 0 in 1 ft 0 in None None 12 S 11 Vinyl Low-E Double Yes 0.35 0.35 44.0 ft2 1 ft 0 in 10 ft 0 in None None 13 W 12 Vinyl Low-E Double Yes 0.35 0.35 49.5 ft2 1 ft 0 in 1 ft 0 in None None 14 N 13 Vinyl Low-E Double Yes 0.35 0.35 30.0 ft2 1 ft 0 in 1 ft 0 in None None 15 N 14 Vinyl Low-E Double Yes 0.35 0.35 27.0 ft2 1 ft 0 in 1 ft 0 in None None 16 N 15 Vinyl Low-E Double Yes 0.35 0.35 13.5 ft2 1 ft 0 in 1 ft 0 in None None 17 S 17 Vinyl Low-E Double Yes 0.35 0.35 13.5 ft2 1 ft 0 in 1 ft 0 in None None 18 S 18 Vinyl Low-E Double Yes 0.35 0.35 27.0 ft2 1 ft 0 in 1 ft 0 in None None 19 S 19 Vinyl Low-E Double Yes 0.35 0.35 30.0 ft2 1 ft 0 in 1 ft 0 in None None 20 W 20 Vinyl Low-E Double Yes 0.35 0.35 49.5 ft2 1 ft 0 in 1 ft 0 in None None 21 N 21 Vinyl Low-E Double Yes 0.35 0.35 8.0 ft2 1 ft 0 in 1 ft 0 in None None 22 E 22 Vinyl Low-E Double Yes 0.35 0.35 27.0 ft2 6 ft 0 in 1 ft 0 in None None 23 E 22 Vinyl Low-E Double Yes 0.35 0.35 35.0 ft2 6 ft 0 in 1 ft 0 in None None 24 N 23 Vinyl Low-E Double Yes 0.35 0.35 16.0 ft2 1 ft 0 in 1 ft 0 in None None 25 E 24 Vinyl Low-E Double Yes 0.35 0.35 8.0 ft2 1 ft 0 in 1 ft 0 in None None 26 E 25 Vinyl Low-E Double Yes 0.35 0.35 8.0 ft2 1 ft 0 in 1 ft 0 in None None 27 S 26 Vinyl Low-E Double Yes 0.35 0.35 27.0 ft2 1 ft 0 in 1 ft 0 in None None 28 S 27 Vinyl Low-E Double Yes 0.35 0.35 13.5 ft2 1 ft 0 in 1 ft 0 in None None 29 N 28 Vinyl Low-E Double Yes 0.35 0.35 37.5 ft2 1 ft 0 in 1 ft 0 in None None 30 W 29 Vinyl Low-E Double Yes 0.35 0.35 15.0 ft2 1 ft 0 in 1 ft 0 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse BestGuess .0003 2610.2 143.29 269.49 .3212 5.0091 1/20/2015 4:35 PM EnergyGauge®USA-FlaRes2010 Section 405.4 1 Compliant Software Page 4 of 6 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:7.7 29.8 kBtu/hr 1 sys#1 2 Electric Heat Pump None HSPF:7.7 34 kBtu/hr 2 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER: 13 29.8 kBtu/hr 894 cfm 0.75 1 sys#1 2 Central Unit None SEER: 13 34 kBtu/hr 1020 cfm 0.75 2 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Natural Gas Tankless Exterior 0.75 1 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS ---Supply---- ----Return---- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 165 ft2 Main 41 ft2 Default Leakage Main (Default) (Default) 1 1 2 Attic 6 165 ft2 Main 41 ft2 Default Leakage Upstairs (Default) (Default) 2 2 TEMPERATURES ProgramableThermostat: Y Ceiling Fans: CoolingJan Feb Mar Apr May X Jun rl Jul X Au rl Se Oct Nov Dec HeatinHJan HFeb Mar Apr f May 4 Jun Jul 4 AuSep Oct Nov Dec Ventin Jan Feb X Mar [X]A r [ Ma [ Jun Jul [ Aug Se [X]Oct HX Nov H Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 1/20/2015 4:35 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: 152 3rd Street PERMIT#: Atlantic Beach, FL, 32233- MANDATORY REQUIREMENTS SUMMARY-See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC-rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating controls and cooling system. Where forced-air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff(gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower(HP)of= 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor-retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site-recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP=4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 1/20/2015 4:35 PM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 6 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 77 The lower the EnergyPerformance Index, the more efficient the home. 152 3rd Street, Atlantic Beach, FL, 32233- 1, 2233-1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=13.0 3080.30 ft2 b. N/A R= ft2 3. Number of units,if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 1412.00 ft2 6. Conditioned floor area(ft2) 3317 b.N/A R= ft2 7. Windows*' Description Area c.N/A R= ft2 a. U-Factor: Dbl,U=0.35 916.90 ft2 11.Ducts R ft2 a.Sup:Attic,Ret:Main,AH:Main 6 165 SHGC: SHGC=0.35 b.Sup: Attic,Ret:Main,AH:Upstairs 6 165 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 29.8 SEER:13.00 SHGC: b.Central Unit 34.0 SEER:13.00 d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 29.8 HSPF:7.70 Area Weighted Average Overhang Depth: 2.990 ft. b.Electric Heat Pump 34.0 HSPF:7.70 Area Weighted Average SHGC: 0.350 8. Floor Types Insulation Area 14.Hot water systems 2 a.Natural Gas Cap:1 gallons a.Slab-On-Grade Edge Insulation R=0.0 1412.00 ft EF:0.75 b.Floor Over Other Space R=0.0 1370.00 ft2 c.N/A R= ft2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building THE S7. Construction through the above energy saving features which will be installed (or exceeded) 1OF = `�r6� in this home before final inspection. Otherwise, a new EPL Display Cardwill be completed based on installed Code co Builder Signature: Date: �ZG Address of New Home: 5`2 3 0' Cit /FL Zip: �� Z 33 cOLD WE�O *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge®USA-Fla Res2010 Section 405.4.1 Compliant Software TABLE 402.4.2 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Hillis 152 3rd St Atlantic Beach Builder Name: Bosco Custom Homes Street: 152 3rd Street Permit Office: Duval City,State,Zip: Atlantic Beach,FL,32233- Permit Number: Owner: Jurisdiction: 261100 Design Location: FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier Exterior thermal envelope insulation for framed walls is installed in substantial contact and continuous alignment with building envelope air barrier. Breaks or joints in the air barrier are filled or repaired. Air-permeable insulation is not used as a sealing material. Air-permeable insulation is inside of an air barrier. Ceiling/attic Air barrier in any dropped ceiling/soffit is substantially aligned with insulation and any gaps are sealed. Attic access (except unvented attic), knee wall door, or drop down stair is sealed. Walls Corners and headers are insulated. Junction of foundation and sill plate is sealed. Windows and doors Space between window/door jambs and framing is sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including Insulation is installed to maintain permanent contact with underside above-garage and of subfloor decking. cantilevered floors) Air barrier is installed at any exposed edge of insulation. Crawl space walls Insulation is permanently attached to walls. Exposed earth in unvented crawl spaces is covered with Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, knee walls and flue shafts opening to exterior or unconditioned space are sealed. Narrow cavities Batts in narrow cavities are cut to fit, or narrow cavities are filled by sprayed/blown insulation. Garage separation Air sealing is provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures are air tight, IC rated, and sealed to drywall. Exception—fixtures in conditioned space. Plumbing and wiring Insulation is placed between outside and pipes. Batt insulation is cut to fit around wiring and plumbing, or sprayed/blown insulation extends behind piping and wiring. Shower/tub on exterior wall Showers and tubs on exterior walls have insulation and an air barrier separating them from the exterior wall. Electrical/phone box on Air barrier extends behind boxes or air sealed-type boxes are installed. Common wall Air barrier is installed in common wall between dwelling units. HVAC register boots HVAC register boots that penetrate building envelope are sealed to subfloor or drywall. Fireplace Fireplace walls include an air barrier. EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software FILE COPY :' Hillis 152 3rd St Atlantic Beach HVAC Load Calculations for Bosco Custom Homes 2158 Mayport Road Atlantic Beach, FL 32233 okpMNIQ RHVACRgS1D$N"flAL HVAC LOADS Prepared By: Jason McDuffie Home Energy Services 2060 Davis Road Jacksonville, FL 32218 904-757-3569 Tuesday, January 20, 2015 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Home Energy Services Hillis 152 3rd St Atlantic Beach Jacksonville,FL 32218 Page 2 Project Report General Project Information Project Title: Hillis 152 3rd St Atlantic Beach Project Date: Tuesday, January 20, 2015 Client Name: Bosco Custom Homes Client Address: 2158 Mayport Road Client City: Atlantic Beach, FL 32233 Client Phone: 904.241.0320 Client Comment: Company Name: Home Energy Services Company Representative: Jason McDuffie Company Address: 2060 Davis Road Company City: Jacksonville, FL 32218 Company Phone: 904-757-3569 Company E-Mail Address: ecalcs@hesjax.com Company Website: www.hesjax.com Design Data Reference City: Jacksonville, Florida Building Orientation: Front door faces North Daily Temperature Range: Medium Latitude: 30 Degrees Elevation: 26 ft. Altitude Factor: 0.999 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 32 29.92 n/a n/a 70 n/a Summer: 94 77 47% 50% 75 48 Check Figures Total Building Supply CFM: 2,269 CFM Per Square ft.: 0.684 Square ft. of Room Area: 3,317 Square ft. Per Ton: 706 Volume(ft3)of Cond. Space: 29,681 Building Loads Total Heating Required Including Ventilation Air: 45,457 Btuh 45.457 MBH Total Sensible Gain: 49,875 Btuh 88 % Total Latent Gain: 6,510 Btuh 12 % Total Cooling Required Including Ventilation Air: 56,385 Btuh 4.70 Tons(Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\...\Hillis 152 3rd St.rh9 Tuesday, January 20, 2015, 3:12 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Home Energy Services Hillis 152 3rd St Atlantic Beach Jacksonville,FL 32218 Page 3 Miscellaneous Report System 1 Main Outdoor Outdoor Outdoor Indoor Indoor Grains Input Data Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 32 29.92 80% n/a 70 n/a Summer: 94 77 47% 50% 75 48.06 System 2 Upstairs Outdoor Outdoor Outdoor Indoor Indoor Grains Input Data Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 32 29.92 80% n/a 70 n/a Summer: 94 77 47% 50% 75 48.06 Duct Sizing Inputs Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. Outside Air Data Winter Summer Infiltration Specified: 0.250 AC/hr 0.250 AC/hr 124 CFM 124 CFM Infiltration Actual: 0.250 AC/hr 0.250 AC/hr Above Grade Volume: X 29,681 Cu.ft. X 29,681 Cu.ft. 7,420 Cu.ft./hr 7,420 Cu.ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 124 CFM 124 CFM Total Building Ventilation: 0 CFM 0 CFM ---System 1--- Infiltration &Ventilation Sensible Gain Multiplier: 20.88 = (1.10 X 0.999 X 19.00 Summer Temp. Difference) Infiltration &Ventilation Latent Gain Multiplier: 32.65 = (0.68 X 0.999 X 48.06 Grains Difference) Infiltration &Ventilation Sensible Loss Multiplier: 41.76 = (1.10 X 0.999 X 38.00 Winter Temp. Difference) Winter Infiltration Specified: 0.250 AC/hr(57 CFM) Summer Infiltration Specified: 0.250 AC/hr(57 CFM) ---System 2--- Infiltration &Ventilation Sensible Gain Multiplier: 20.88 = (1.10 X 0.999 X 19.00 Summer Temp. Difference) Infiltration &Ventilation Latent Gain Multiplier: 32.65 = (0.68 X 0.999 X 48.06 Grains Difference) Infiltration &Ventilation Sensible Loss Multiplier: 41.76 = (1.10 X 0.999 X 38.00 Winter Temp. Difference) Winter Infiltration Specified: 0.250 AC/hr(67 CFM) Summer Infiltration Specified: 0.250 AC/hr(67 CFM) Duct Load Factor Scenarios for System 1 Attic Duct Duct Surface From No. Type Description Location Ceiling Leakage Insulation Area MDD 1 Supply Main Attic 16B 0.09 6 381 No 1 Return Main Attic 16B 0.15 6 71 No Duct Load Factor Scenarios for System 2 Attic Duct Duct Surface From No. Type Description Location Ceiling Leakage Insulation Area [T]MDD 1 Supply Main Attic 16B 0.09 6 514 No 1 Return Main Attic 16B 0.15 6 95 No C:\ ...\Hillis 152 3rd St.rh9 Tuesday, January 20, 2015, 3:12 PM rWhvac- ential&Lighto- meetial HVACLoads' Etfe Software Development,Inc. Home Energy Services Hillis 152 3rd St Atlantic Beach Jacksonville,FL 32218 Page 4 Load Preview Report Net ft Sen Lat Net Sen Sys Cls Act Duct Scope Ton /Ton Area Gain Gain Gain Loss g g'i Size CFM CFM', CFMI Building 4.70 706 3,317 49,875 6,510 56,385 45,457 919 2269 2,269 System 1 2.20 642 1,412 23,011 3,353 26,364 24,893 503 1,047 1,047 12x16 Duct Latent 702 702 Zone 1 1,412 23,011 2,651 25,662 24,893 503 1,047 1,047 12x16 1-Entry 84 537 62 599 919 19 24 24 1-4 2-Living 510 10,391 1246 11,637 8,782 178 473 473 4.-6 3-Pantry 60 463 150 613 1,509 31 21 21 1 -4 4-Bath 1 24 422 0 422 0 0 19 19 1-4 5-Dining 248 2,222 206 2,428 3,209 65 101 101 14 6-Kiichen 270 4,798 612 5,410 5,211 105 218 218 2-5 7-Sifting 216 4,178 375 4,553 5,263 106 190 190 1-8 System 2 2.50 762 1,905 26,864 3,156 30,021 20,564 416 1,222 1222 12x18 Duct Latent 970 970 Zone 1 1,905 26,864 2,186 29,050 20,564 416 1,222 1222 12x18 8-Study 1 150 4,349 283 4,632 2,762 56 198 198 1-8 9-Bedroom 1 182 2,154 160 2,314 1,295 26 98 98 1-5 10-Bath 2 110 881 160 1,041 1,198 24 40 40 1-4 11-Laundry 35 450 0 450 0 0 20 20 1-4 12-Bath 3 40 492 62 554 595 12 22 22 1-4 13-Bedroom 2 169 2,312 160 2,472 1,407 28 105 105 14 14-Study 2 150 4,558 283 4,841 2,912 59 207 207 1-9 15-Master Bedroom 270 4,413 267 4,680 2,902 59 201 201 2-5 16-M WIC 1 60 1,388 197 1,585 1,509 31 63 63 1-5 17-Master Bath 144 2,121 314 2,435 2,447 49 96 96 1-6 18-M Toilet 15 435 62 497 550 11 20 20 1-4 19-M WIC 2 45 34 0 34 26 1 2 2 1-4 20-Attic 535 3277 238 3,515 2,962 60 149 149 1-7 C:\...\Hillis 152 3rd StA9 Tuesday, January 20, 2015, 3:12 PM R iOdd`- esidential&11-110MICommercial HVAC Loads Elite Software Development,Inc. Home Energy Services Hillis 152 3rd St Atlantic Beach Jacksonville,FL 32218 Page 5 Duct Size Preview Room or Source Minimum Maximum Rough. Desgn SP Duct Duct Htg Clg Act. Duct Duct Name Velocity' Velocity Factor L/100 Loss Velocity. Length Flow Flow Flow Size System 1 Supply Runouts Zone 1 1-Entry Built-In 450 750 0.01 0.1 279.9 19 24 24 1-4 2-Living Built-In 450 750 0.01 0.1 602 178 073 473 44 3-Pantry Built-In 450 750 0.01 0.1 241.2 31021 21 1-4 4-Bath 1 Built-In 450 750 0.01 0.1 220 0 K 19 19 1-4 5-Dining Built-In 450 750 0.01 0.1 514.9 65 101 101 1-6 6-Kitchen Built-In 450 750 0.01 0.1 555.9 105 218 218 2-6 7-Sitting Built-In 450 750 0.01 0.1 544.6 106 190 190 1-8 Other Ducts in System 1 Supply Main Trunk Built-In 650 900 0.003 0.1 785.2 503 1,047 1,047 12x16 System 2 Supply Runouts Zone 1 8-Study 1 Built-In 450 750 0.01 0.1 566.9 56 198 198 1--8 9-Bedroom 1 Built-In 450 750 0.01 0.1 499 26 98 98 1-6 10-Bath 2 Built-In 450 750 0.01 0.1 459.6 24 40 40 1-4 11-Laundry Built-In 450 750 0.01 0.1 234.6 O20 20 1-4 12-Bath 3 Built-In 450 750 0.01 0.1 256.6 12 22 22 1-4 13-Bedroom 2 Built-In 450 750 0.01 0.1 535.7 28 105 105 1-6 14-Sludy2 Built-In 450 750 0.01 0.1 469.4 59 r 207 207 1-9 15-Master Bedroom Built-In 450 750 0.01 0.1 511.3 59 201 201 2-6 16-M WIC 1 Built-In 450 750 0.01 0.1 463.2 31 63 63 1-5 17-Master Bath Built-In 450 750 0.01 0.1 491.4 49 y 96 96 1-6 18-M Toilet Built-In 450 750 0.01 0.1 227 11W,20 20 1-4 19-M WIC 2 Built-In 450 750 0.01 0.1 17.9 1 E 2 2 1-4 20-Attic Built-In 450 750 0.01 0.1 557.8 60 Plll149 149 1-7 Other Duds in System 2 Supply Main Trunk Built-In 650 900 0.003 0.1 814.8 416 1222 12x18 Summary System 1 Heating Flow: 503 Cooling Flow: 1047 System 2 Heating Flow: 416 Cooling Flow: 1222 !o C:\...\Hillis 152 3rd St.rh9 Tuesday, January 20, 2015, 3:12 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Home Energy Services Hillis 152 3rd St Atlantic Beach Jacksonville,FL 32218 Page 6 Total Building Summary Loads Component Area Sen Lat Sen Total Description Quan Loss Gain Gain Gain 10D-f: Glazing-French door, double pane low-e glass(e = 197.6 2,626 0 4,234 4,234 0.10), insulated fiberglass frame, u-value 0.35, SHGC 0.35 4A-6-o: Glazing-Double pane low-e(e = 0.20 or less), 628.3 8,356 0 13,855 13,855 high performance, operable window, a=0.05 on surface 2, any frame, u-value 0.35, SHGC 0.35 4A-6-d: Glazing-Double pane low-e(e = 0.20 or less), 91 1,212 0 1,492 1,492 high performance, sliding glass door, a=0.05 on surface 2, any frame, u-value 0.35, SHGC 0.35 12C-0sw: Wall-Frame, R-13 insulation in 2 x 4 stud 2163.4 7,483 0 5,020 5,020 cavity, no board insulation, siding finish, wood studs 16B-30: Roof/Ceiling-Under Attic with Insulation on Attic 1489.2 1,811 0 2,574 2,574 Floor(also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-30 insulation 22A-ph: Floor-Slab on grade, No edge insulation, no 155 7,998 0 0 0 insulation below floor, any floor cover, passive, heavy moist soil Subtotals for structure: 29,486 0 27,175 27,175 People: 4 800 920 1,720 Equipment: 0 7,600 7,600 Lighting: 200 682 682 Ductwork: 10,806 1,673 10,368 12,041 Infiltration: Winter CFM: 124, Summer CFM: 124 5,165 4,037 2,580 6,617 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 AED Excursion: 0 0 550 550 Total Building Load Totals: 45,457 6,510 49,875 56,385 Check Figures .. Total Building Supply CFM: 2,269 CFM Per Square ft.: 0.684 Square ft. of Room Area: 3,317 Square ft. Per Ton: 706 Volume(ft')of Cond. Space: 29,681 Building Loads Total Heating Required Including Ventilation Air: 45,457 Btuh 45.457 MBH Total Sensible Gain: 49,875 Btuh 88 % Total Latent Gain: 6,510 Btuh 12 % Total Cooling Required Including Ventilation Air: 56,385 Btuh 4.70 Tons(Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\...\Hillis 152 3rd St.rh9 Tuesday, January 20, 2015, 3:13 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Home Energy Services Hillis 152 3rd St Atlantic Beach Jacksonville,FL 32218 Pa e 7 Building Pie Chart Infiltration 11% Floor 18% Roof 4% Building Ductwork 24% Loss 45,457 Btuh Wall 16% Glass 27% Roof 5% ED Excursion 1% Wall 9% Infiltration 12% Building Ductwork 21% Gain 56,385 Btuh Glass 35% Lighting 1% Equipment 13% People 3% C:\...\Hillis 152 3rd St.rhg Tuesday,January 20, 2015, 3:13 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Home Energy Services Hillis 152 3rd St Atlantic Beach Jacksonville FL 32218 Page 8 System 1 Room Load Summary Htg Min Run Run Clg Clg Min Act Room Area Sens Htg Duct Duct Sens Lat Clg Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM ---Zone 1--- 1 Entry 84 919 19 1-4 280 537 62 24 24 2 Living 510 8,782 178 4-6 602 10,391 1,246 473 473 3 Pantry 60 1,509 31 1-4 241 463 150 21 21 4 Bath 1 24 0 0 1-4 220 422 0 19 19 5 Dining 248 3,209 65 1-6 515 2,222 206 101 101 6 Kitchen 270 5,211 105 2-6 556 4,798 612 218 218 7 Sitting 216 5,263 106 1-8 545 4,178 375 190 190 Duct Latent 702 System 1 total 1,412 24,893 503 23,011 3,353 1,047 1,047 System 1 Main Trunk Size: 12x16 in. Velocity: 785 ft./min Loss per 100 ft.: 0.092 in.wg Cooling Cooling Sensible/Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 2.20 87% / 13% 23,011 3,353 26,364 Actual: 2.48 75% /25% 22,350 7,450 29,800 Equipment Data Heating System Cooling System Type: Air Source Heat Pump Air Source Heat Pump Model: CH 13NA030****A CH 13NA030"""'A Indoor Model: FB4CNP036 Brand: CARRIER AIR CONDITIONING CARRIER AIR CONDITIONING Description: Air Source Heat Pump Air Source Heat Pump Efficiency: 7.7 HSPF 13 SEER Sound: 0 0 Capacity: 29,600 Btuh 29,800 Btuh Sensible Capacity: n/a 22,350 Btuh Latent Capacity: n/a 7,450 Btuh AHRI Reference No.: n/a 7425708 C:\ ...\Hillis 152 3rd St.rh9 Tuesday, January 20, 2015, 3:13 PM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Home Energy Services Hillis 152 3rd St Atlantic Beach Jacksonville,FL 32218 -* Page 9 System 2 Room Load Summary Htg Min Run Run Clg Clg Min Act Room Area Sens Htg Duct Duct Sens Lat Clg Sys No Name SF Btuh CFM Size Vel Btuh Btuh CFM CFM ---Zone 1--- 8 Study 1 150 2,762 56 1-8 567 4,349 283 198 198 9 Bedroom 1 182 1,295 26 1-6 499 2,154 160 98 98 10 Bath 2 110 1,198 24 1-4 460 881 160 40 40 11 Laundry 35 0 0 1-4 235 450 0 20 20 12 Bath 3 40 595 12 1-4 257 492 62 22 22 13 Bedroom 2 169 1,407 28 1-6 536 2,312 160 105 105 14 Study 2 150 2,912 59 1-9 469 4,558 283 207 207 15 Master Bedroom 270 2,902 59 2-6 511 4,413 267 201 201 16 M WIC 1 60 1,509 31 1-5 463 1,388 197 63 63 17 Master Bath 144 2,447 49 1-6 491 2,121 314 96 96 18 M Toilet 15 550 11 1-4 227 435 62 20 20 19 M W I C 2 45 26 1 1-4 18 34 0 2 2 20 Attic 535 2,962 60 1-7 558 3,277 238 149 149 Duct Latent 970 System 2 total 1,905 20,564 416 - 26,864 3,156 1,222 1,222 System 2 Main Trunk Size: 12x18 in. Velocity: 815 ft./min Loss per 100 ft.: 0.093 in.wg Cooling System Summary Cooling Sensible/Latent Sensible Latent Tons Split Btuh Btuh Btuh Net Required: 2.50 89% / 11% 26,864 3,156 30,021 Actual: 2.83 75%/25% 25,500 8,500 34,000 E ui ment Data Heating Svstem Cooling System Type: Air Source Heat Pump Air Source Heat Pump Model: CH13NA036****C CH13NA036****C Indoor Model: FPMAN*036+TXV Brand: CARRIER CARRIER Description: Air Source Heat Pump Air Source Heat Pump Efficiency: 7.7 HSPF 13 SEER Sound: 0 0 Capacity: 33,400 Btuh 34,000 Btuh Sensible Capacity: n/a 25,500 Btuh Latent Capacity: n/a 8,500 Btuh AHRI Reference No.: n/a 7088476 C:\ ...\Hillis 152 3rd St.rh9 Tuesday, January 20, 2015, 3:13 PM I • a Y a C d � • d O C O O n m ii n i � i iii iimiiuu m p • E ro W V � C w � fl1 W .J v� c CL Q Q 4 6n Ln V1 V1 61 Ln V) 1Y� Ln V) 6-1 V1 V1 "I H rl r1 H HN wy H rl rpl H �1 .ti N O 0 0 r4 N N N N\ O N • Z' N M M N . 14 N M M � N a. m 'u m E ,Z w � E E � • aci „� a ; O ariy z o U v 0 UaU 0 V U v Q E C Z E CC E E m V, a �uya o- "' EQ d EQ E A N N 1• W •�• ��_ .� 1.1 uN 1.1 City of Atlantic Beach ; ` -'--+C IN'TRIC APPLICATION NUMBER •} Building Department +eminole Road FEB 1 2015 (To be assigned by the Building Department.) 800 Si 1 s� Atlantic Beach, Florida 32233-5445 J Phone(904)247-5826 Fax(904)24745 E-mail: building-dept@coab.us Date routed: City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: /�Z1 ,6 J7" a rtment review required Yes No Applicant: Planning &Zoning Tree ministrator Project: Ah)>l7 _dh `* 0PubIicWSaFet_y lic lic Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St.Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: Mapproved. ❑Denied. (Circle one.) Comments: BUILDING PLANNING&ZONING Reviewed by: � �'"�''-- Date: 2-1 15'//� TREE ADMIN. Second Review: [—]Approved as revised. ❑Denied. *LICWO S Comments: PUBIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 07/27/10 City of Atlantic Beach APPLICATION NUMBER Building Department RECEIVE (To be assigned by the Building Department.) ` 800 Seminole Road ���1b +S/? Atlantic Beach, Florida 32233-5445 FEB 12015 J Phone(904) 247-5826 - Fax(904)247 845 I ;D)' E-mail: building-dept@coab.us Date routed: o2 /, /S City web-site: http://vmw.coab.us 13y: APPLICATION REVIEW AND TRACKING FORM Property Address: 4a- 37� d Jr JJepartment review required Yes No Applicant: Planning &Zoning / Tree ministrator Project: � �'j�j��-j — ,e,4 Am ok �15ublic Wor ublic Utilities Public Sa ety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. ❑Denied. (Circle one.) Comments: BUILDING PLANNING&ZONING Reviewed by: Date: TREE ADMIN. Second Review: ❑Approved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. ❑Denied. Comments: Reviewed by: Date: Revised 07/27/10 rsr�,it, City of Atlantic Beach APPLICATION NUMBER n Building Department (To be assigned by the Building Department.) 800 Seminole Road l�-teo b Atlantic Beach, Florida 32233-5445 �J Phone(904) 247-5826 - Fax(904)247-5845 hh E-mail: building-dept@coab.us Date routed: C` City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: 1.5"2- � ,6 JT" e rtment review required Yes No Applicant: Planning &Zoning Tree ministrator Project: _-J -12)F77 j el-A0 Qlk 6 ublic Wor ublic Utilities Public Sa ety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. Denied. (Circle one.) Comments: BUILDING SLL "r Jv PLANNING &ZONING Reviewed by:, Date: TREE ADMIN. Second Review: ❑Approved as revised. Denied. PUBLIC WORKS Comments: ✓cG A141. 1 L f eh t(// / PUBLIC UTILITIES f��"� PUBLIC SAFETY Reviewed by: �v C/ 'A_' Date: FIRE SERVICES Third Review: (Approved as revised. ❑Denied. Comments: / ` Reviewed by: ! �� Date: 31', ,� Revised 07/27/10 rsy���rCity of Atlantic Beach APPLICATION NUMBER S+ Building Department (To be assigned by the Building Department.) 800 Seminole Road Atlantic Beach, Florida 32233-5445 Phone(904) 247-5826 • Fax(904)247-5845 �1L11 115 E-mail: building-dept@coab.us Date routed: O` City web-site: http://www.coab.us APPLICATION REVIEW AND TRACKING FORM Property Address: /5"'2- c r d J77 )-epaftment review required Yes No Applicant: IZ04 t7a Planning &Zoning /mac Tree ministrator Project: ��f j�� - ,C,c A'd G1� ublic wor ublic Utilities Public Safety Fire Services Review fee $ Dept Signature Other Agency Review or Permit Required Review or Receipt Date of Permit Verified By Florida Dept. of Environmental Protection Florida Dept. of Transportation St. Johns River Water Management District Army Corps of Engineers Division of Hotels and Restaurants Division of Alcoholic Beverages and Tobacco Other: APPLICATION STATUS Reviewing Department First Review: ❑Approved. ❑Denied. (Circle one.) Comments: / �O�- RPaS. e clo had a fJerrn BUILDING V/1 1d & sedrvAcl Sp/- 0-F �h �►��P/�rrtS p �Gth 5 Gi r,t PLANNING&ZONING s4a vnppe/ by/ nyse l F d-r DA- P Reviewed A- Reviewed by: Date: TREE ADMIN. ❑App Second Review: roved as revised. ❑Denied. PUBLIC WORKS Comments: PUBLIC UTILITIES PUBLIC SAFETY Reviewed by: Date: FIRE SERVICES Third Review: ❑Approved as revised. []Denied. Comments: Reviewed by: Date: Revised 07/27/70 S 'fir City of Atlantic Beach Building and Zoning SS 800 Seminole Road Atlantic Beach, Florida 32233 Telephone(904)247-5826 Fax(904)247-5845 http://www.coab.us March 10, 2015 152 3rd Street 2nd Zoning Review Comments 1. Shade Trees: Old Atlantic Beach Design Standards require at least two shade trees on the property with at least one located in the front yard. Please show these trees in the Tree Removal Permit Application or a landscape plan, whether existing or to be planted. In this case the front yard is the area within 20 feet of the property line along Ocean Boulevard. Derek W. Reeves Zoning Technician TREE & VEGETATION AFFIDA s, City of Atlantic Beach Department of Community Development EBy :] Planning&Zoning Division 800 Seminole Road Atlantic Beach, FL 32233 J'i1,r (P)904 247-5800 (F) 904 247-5845 SECTION I -APPLICANT INFORMATION F Owner(s) FX Legal Authorized Agent* NAME OF APPLICANT Todd Bosco i NAME OF COMPANY Bosco Building Contractors,Inc. ADDRESS OF COMPANY 2158 Mayport Rd Atlantic Beach,FL 32233 PHONE (904)241-0320 CELL (904)233-0904 EMAIL todd@boscocbc.com CONTRACTOR CERTIFICATION NUMBER CBC 1250212 ATLBCH BUSINESS TAX RECEIPT NUMBER SECTION II -SITE INFORMATION STREET ADDRESS OF PROPERTY 152 3rd Street Atlantic Beach,FL 32233 If an address has not been assigned to this property,contact the AB Building Department at (904)247-5826 to request an address. LEGAL DESCRIPTION 5-69 16-2S-29E.15 ATLANTIC BEACH LOT 6 BLOCK 28 SUBDIVISION ATLANTIC BEACH REAL ESTATE NUMBER LOT OR PARCEL SIZE: SQ FT AC RESIDENTIAL COMMERCIAL OTHER(SPECIFY) W Am 1 affirm that 1 have reviewed the provisions of Chapter 23, 'Protection of Trees and Native Vegetation" of the Municipal Code of Ordinances for the City of Atlantic Beach, FL and/or I have participated in a pre-application meeting with the Administrator of those regulations. Subsequently r t regulated es and no regulated vegetation will be damaged, destroyed and/or removed from the above-describe a t In conjunction with this project. SIGNATURE OF OWNER SIGNATURE OF OWNER O — Signed and sworn before me on this��day of by State of �o?�� -r0Q j) 1z9fGo County of ptff/,4L Identification verified: Oath sworn: r Yes fT No WILLIAM L.POPE Notary Signature Notary Public,State of Florida My Comm.Expires Oct.19,2015 My Commission expires: RFV-TV= Commission No.EE 128745 -e� -t o TDOW -2I 2Jlol iCj City of Atlantic Beach r5 Building and Zoning 800 Seminole Road J US Atlantic Beach, Florida 32233 Telephone(904)247-5826 � Fax(904) 247-5845 http://www.coab.us February 24, 2015 152 3rd Street Zoning Review Comments 1. Side Wall: Old Atlantic Beach Design Standards limit the maximum length of a second floor side wall to 35 feet long without relief. The second floor side wall on the south side of the building exceeds this. Please revise plans to show an offset that breaks up the second floor side wall. 2. Tree Removal: Please submit a Tree Removal Permit Application if any trees are to removed. If no trees are to be removed, then please fill out an Affidavit of No Tree Removal. Both forms are available on the city website under"Planning and Zoning" and at City Hall. 3. Shade Trees: Old Atlantic Beach Design Standards require at least two shade trees on the property with at least one located in the front yard. Please show these trees in the Tree Removal Permit Application or a landscape plan, whether existing or to be planted. In this case the front yard is the area within 20 feet of the property line along Ocean Boulevard. Derek W. Reeves Zoning Technician PUBLIC WORKS PLAN REVIEW COMMENTS Date: �f /•5 Initials: PN ML Project Name/Address :�� Application Permit#: _ G_/4 _r Check Box Chee A �_ to Add Box tc pplicatio Comment "Print' IMPS Provide table of impervious surface Calc ❑ ❑ construction). , ESCP Provide erosion and sediment control pl ❑ ❑ schedule. o, r DPLN Provide drainage plans showing site top ❑ ❑ RMRO All runoff must remain on-site. Cannot i ❑ ❑ runoff. )C,( ST w c" CSMP Provide construction site management f ❑ ❑ right-of-way for construction parking. TSUR Provide a pre-construction topographic! ( � lal ❑ Land Surveyor, showing 1'contours. Section 24-66(b)of the Land Development Regulations requires on-site storage for LDCS increased run-off if adding 400 SF or more impervious surface. Provide Delta volume ❑ ❑ calculations and on-site retention required per Section 24-66(b). (See attached information sheet.) PCTS If on-site storage is required, a post construction topographic survey documenting proper ❑ ❑ construction will be required. RWPM A Right-of-Way Permit must be obtained for use ❑ ❑ REPM A Revocable Encroachment Permit must be obtained. ❑ ❑ PLWP Pool—Wellpoint(if used) must discharge into vegetated area 10' minimum from street or ❑ ❑ drainage feature (swale, structure or lagoon). All concrete driveway aprons must be 5"thick,4000 psi, with fibermesh from edge of DAPR pavement to the property line. Reinforcing rods or mesh are not allowed in the right-of- ❑ ❑ way. (Commercial driveways—6" thick.) Any utility cuts in the road must be repaired using COJ Standard Detail Case X and must be URCT overlaid 10 feet in each direction from the center of the cut. Repair must be shown on the ❑ ❑ plans. RWRS Full right-of-way restoration, including sod, is required. ❑ Roll off container company must be on City approved list and container cannot be placed on ROFF City right-of-way. (Approved:Advanced Disposal, Realco Recycling, Republic Services, ❑ ❑ Shappel's and Waste Pro). Full erosion control measures must be installed and approved prior to beginning any earth ECIN disturbing activities. Contact Public Works(247-5834)for Erosion and Sediment Control ❑ ❑ Inspection prior to start of construction. MEET Recommend Owner/Contractor meet with Public Works Director to discuss proposed ❑ ❑ constructions. Call 247-5834 to make an appointment. -T" i S A 2.n, t T lel JCS& L / .0 �or �j c�avC.-I'—�o✓ �DC/$ ❑ ❑ vjL - ('X� Cr F'EQ1vt T 15---P-ra DD —3/3 0 0 is Sf��G y 3 Z, �q C_ .¢.CPo (-r i 2 S/le 171 /14,+., Alo dsl . 3 3 Z8' 3- 25G7s. 7S -s (so > //S C21- Ys) ( 570t20) GS, 3 S- 7 7 1 COMP. (3y: MLS �, Date: 2/9/2015 rj )� Public Works Department City of Atlantic Beach Pernik No: Pre-Dev Address: >(J j` Atlantic Beach,FL I Required Stora- e V m Criteria: Section 24-66 of the Cq of Atlantic Beach's Zoning,Subdivsion,and Land Development Regulations requires that the difference between the pre-and postdevelo mant volume of stormwawter runoff be stored on site. Volume of Runoff is defined as follows: V=CAR/12 Where: V=Volume of Runoff C=Coefficient of Runoff A=Area of lot insquare feet R=25-yr/24-hr rainfall depth 9.3-inches for Atlantic Beach Lot Area A = 6,553 ftp 152 3rd street Lot 6 Runoff Coefficient Area Lot Area Description (fe) (ftr) L "C" Wtd"C" Impervious 3,507 6,553 1.00 0.54 Pervious 3,046 6,563 0.20 0.09 Runoff Coefficient(C)= 0.63 Runoff Volume V= 0.63 x 6,553 x 9.3 / 12 V= 3,190 ft' Postdevelo ment Runoff Volumw Lot Area(A) = 6,653 ft= Runoff Coefficient Area Lot Area Description (ftZ) (ft) "C" Wtd"C" Impervious 6,553 1.00 0.48 ISA= 46.3% Pervious 3,385 6,553 1 0.20 0.10 Runoff Coefficient(C)= 0.59 Runoff Volume V= 0.59 x 6.553 x 9.3 f 12 V= 2,980 ft3 Reguired Storage Volume DV= Postdevelopment Runoff Volume-Predevelo ment Runoff Volume DV= 2.980-- 3,190 DV= -210 eft' Provided Storaoir Elevation Area Storage ft fe (ft') 0.0 80 0 BOTTOM 4'x 20' 0.33 420 83 TOB 14'x30' Elevation Area Storage ft (ft) 0.0 33 0 BOTTOM 0.6'x 66' 0.1 355 23 TOB 5'x 71' Elevation Area Storace i Com . B : MLS Date: 2/9/2015 k Public Works De artment Cl of Atlantic Beach r Permit No: Pro-Dev Address: AU l 3 r►tlantic Beach,FL Required Storage Volume Criteria, Section 24-66 of the City of Atlantic Beach's Zoning,Subdivsion,and Land Development R ulations uires that the difference between the re-and posticlevelo ment volume of stormwawler runoff be stored on site. Volume of Runoff is defined as follows: V=CAR/12 t i Where: V=Volume of Runoff C=Coefficient of Runoff A=Area of lot in uare feet R=25 /24-hr rainfall depth(9.3-inches for Atlantic Beach Predevelooment Ru r - Hoff Volume: Lot Area(A) = 6,553 ft2 152 3rd street Lot 6 Runoff Coefficient Area Lot Area Description (ft2) ft2 C. Wtd"C" Impervious r 6,553 1.00 O.S4 Pervious 3,046 6.553 0.20 0.09 - Runoff Coefficient C = 0.63 Runoff Volume V=c- 0.63 x 6,553 x 9.3 / V= 3,190 ft' 12 Postdovellopma Lot Area A = 6,553 ft2 Runoff Coefficlent e Area Lot Aro- Descri n ft ft2 C. Wtd"C" Impervious 6,553 1.00 0,4g = - 46.3% Pervious 3,365 6,553 0.20 0.10 Runoff Coefficient C = 0.59 _- Runoff Volume V= 0.59 x 6,553 x 9.3 / 12 g V= 2,960 ft2 Reaul DV= Postdevelo ment Runoff Volume-Predevelo ment Runoff Volume DV= 2,960 3,190 DV= -210 ft2 Provided Stora : Elevation Area Store e ft ft 0.0 60 0 BOTTOM 4'x 20' 4 0.33 420 63 TOB 14'x 30' g Elevation Area Sto € ft ft2 0.0 33 0 BOTTOM 0.5'x 66' 0.1 355 23 TOB 5'x 71' Elevation Area Storage i ITY OF ATLANTIC BEACH J 800 SIEMINO LE ROAD ATLANTIC BEACH,FL 32233 04 (904) 247-5800 i o Re nest ISh t Date:y -�'r- /r V --------_� Received by: Permit Number: Resubmitted: Original Pians Clearance S aminer: heet Number: . � Project Addres -- -- — Project Naive: t Contractor: ��� -------__—_-_ ' Contact Name:— - Contact Phone Number: �I� O - — -- Contact.Fax Number: �1 0S Revision/Plan Check/Permit Fee(s)Due: $ )<Descri tion of Pro osed Revision to>Existina)f'ermit: Pending Hold: Structural: C _ Plumbing: -. Mechanical• -_-,- ---------------- Electrical: Misc.. -_ ----- - -------------- ---------------- - ---------- Additional Increase in Building Value: $ Clearance Sheet/Site Plan Revi d: ----- Additional Square Footage: By signing below,f ------- _ Ellviroiunental Health Approval: puoposed ehanges. ------ -------- aft11'rn that the above revision is inclusive of the Signatuta' f Cbnu•ac or a cent(Contracto'must sign ifincrease in valuation) ✓ Date: ,5^- Office Use only P1�1eOU,' 5C0.2 AV `s� Approved: _ Rejected: / L Plan Review C'ounments: �-P►'I77f --- ---- C,rc-led a da/my r. Plans Exai Crcaled 08/O5/OS.j1, V Da