Loading...
1835 SELVA GRANDA 2015 HVAC ...r��V CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH, FL 32233 INSPECTION PHONE LINE 247-5814 MECHANICAL HVAC PERMIT MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 15-MECH-685 Job Type: MECHANICAL HVAC ONLY Description: 1 cu 1 ahu 3.5 Estimated Value: Issue Date: 3/26/2015 Expiration Date: 9/22/2015 PROPERTY ADDRESS: Address: 1835 SELVA GRANDE DR RE Number: 169542-5034 PROPERTY OWNER: Name: MANN, KENNETH Address: 72 S EAST SHORE RD GENERAL CONTRACTOR INFORMATION: Name: DONOVAN HEATING & AIR Address: 315 SIXTH AVENUE S QA WILLIAM J DON OVAN Phone: - - PERMIT INFORMATION: Sticker for overcurrent protection must be on A/C equipment prior to inspection. Failure to comply will result in a failed inspection and reinspect fees. No exceptions. FEES: Furnaces and Heating $24.00 AC and Refrigeration $28.00 State Mech DBPR Surcharge $2.00 State Mech DCA Surcharge $2.00 Trade Permit Base Fee $55.00 Total Payments: $111.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION --.004W CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach, FL 32233 Ph(904) 247-5826 Fax(904) 247-5845 (oB ADDRESS: �J a l�"Y�'��' . 1 J r PERMIT# PROJECT VALUE $ ARI#–7q `-t q 33 REQUIRED Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Seer Rating Heat: Unit Quantity BTU's Per Unit gREQUIRED Duct Systems: Total CFM REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit 3• S Heat: Unit Quantity I BTU's Per Unit—q!:.-060 Seer RatingREQUIRED Duct Systems: Total CFM FIRE PREVENTION 3 sets of plans) Fire Sprinkler System Quantity (Requires Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks(gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read tis application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction. Property Owners Name.PN �j I1��!r� Phone Number F 62 131 191a Mechanical Company :DLA 0V Office Phone 2y1 VK Fax A 3-7 4) rim S City jb gc� State _Zip32ZZ Co. Address: License Holder(Print): ll1 �a State Certification/Registration# rAco3bAl Notarized Signature of License Holder E RICHARD TOMPKINSBefore me this a3 day o y 20= Commission#FF 040399 ;<: Expires July 29,2ot7 Signature of Notary Public t 7010 Bonded Tin Tmy Fan Inwn�+ea BOD�385- This combination qualifies for a Federal Energy Efficiency Tax Credit when placed in service &OW on ILN CERTIFIEDbetween Feb 17, 2009 and Dec 31,2014. www,ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 7914933 Date: 3/17/2015 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 25HBC542A*030 Indoor Unit Model Number: FX4DN(B,F)043L Manufacturer: CARRIER AIR CONDITIONING Trade/Brand name: CARRIER AIR CONDITIONING Series name: COMFORT SERIES PURON HP Manufacturer responsible for the rating of this system combination is CARRIER AIR CONDITIONING Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 41500 EER Rating (Cooling): 12.50 SEER Rating (Cooling): 15.00 Heating Capacity(Btuh) @ 47 F: 42000 Region IV HSPF Rating (Heating): 8.50 Heating Capacity(Btuh)@ 17 F: 26400 Ratings followed by an asterisk(')indicate a voluntary rerate of previousty published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility or, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory atwww.ahridirectory.org. � ��� TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall Doty be used for individual,personal and ■■ confidential reference purposes.The contents of this Certificate may not,in whole or in part.be reproduced;copied;disseminated: klu entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual, AIR-CONDITIONING,HEATING. personal and confidential reference. &REFRIGERATION INSTITUTE CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org,dick on"Verify Certificate"link He make life better' and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above,and the Certificate No.,which is listed at bottom right CERTIFICATE NO.: 130710929680572810 ©2014 Air-Conditioning,Heating,and Refrigeration Institute