FLORIDA BUILDING CODE,ENERGY CONSERVATION
FORM 402.2010 Residential Building Thermal Envelope Approach ALL CLIMATE ZONES
Scope:Compliance with Section 402 of the Florida Building Code,Energy Conservation.shall be demonstrateo by the use of Form 402 for single-and multiple-lmnily residences of three
stories or less in height,additions to existing residential buildings,renovations to existing residential buildings,new heating,cooling,and water heating systems in existing buildings,as
applicable.To comply,a building must meet or exceed all of the energy efficiency requirements on Table 402A and all appplicable mandatory requirements summarized in Table 402B of this
form.If a building does not comply with this method or Alternate Form 402,it may still comply under Section 405 of theFlorida Building Code,Energy Conservation.
PROJECT NAME: RenOVatlon BUILDER:
50 S Forrestal Cir ---- - -
AND ADDRESS: .Atlantic Beach PERMITTING OFFICE. Atlantic Beach
OWNER: PERMIT NO.: Me Ch-79 JURISDICTION NO.: 261100
General Instructions:
1.New construction which incorporates any of the followingg features cannot comply using this method:glass areas in excess of 20 percent of conditioned floor area,electric resistance
heat and air handlers located 1n attics.Additions<600 sq.ft.,renovations and equipment changeeuts may comply by this method with exceptions given.
2.Fill in all the applicable spaces of the"To Be Installed"column on Table 402A with the information requested.All"To Be Installed"values must be equal to or mor
required levels. M O -4
3.Complete page 1 based on the"To Be Installed"column information.
4.Read the requirements of Table 4028 and check each box to indicate your intent to comply with all applicable items.
5.Read,sign and date the"Prepared By"certification statement at the bottom of page 1.The owner or owners agent must also sign and date the form.
Please Print OCK0 O
1. New cor Pim�y t S-C 0 n 1. Existing l7v� 5; U3
2. Single-f: t IF ) /jj 2_ Single-family ♦/Z� W
3. If multip y� �{J� / .vwu' -�
4. Is this a 'l '" f l `e -PC,a- S� 4. NO
5. Conditic 5, 925 Sq ft
6. Glass IV C1 Ie 0 M
;1. 6a. _ y'
b. I ;ing existing 6b. _ ��
windows 6c. No New Net sq.ft. 0
7. Percent �h a 7 Z f71
8. Floor ty ///��� ��/
a. 8a.R=_ _ sq.ft. -_
8c.R= -sq.ft.
`1 + , 8d.R= sq.ft.
c. A �z Ae f�' ,�� [ "-/r''� � 8e.R= sq.ft.9. Wall tyl / / 7 q e
a' 9a-1. R=_ sq.ft. --
9a-2. R=_ --sq.ft. _-----------
b.Adjacent: 1. Nlasonry(llo- tio�n�f-value) 9b-1. R= sq.ft. -_
2. Wood frame(Insulation R-value) 9b-2. R= -sq.ft.
10. Ceiling type,area and insulation:
a.Under attic(Insulation R-value) 10a.R= -sq.ft. _
b.Single assembly(Insulation R-value) 10b.R= _sq.ft. -_
11. Air distribution system:Duct insulation,location,On
a.Duct location,insulation 11a. R= 6 _ --
b.AHU location 11 b.
c.Qn,Test report attached(<0.03:yes/no) 11 a-Test report attached? YesO Nod -_
12. Cooling system:
a Type 12a.Type: Central --
b.Efficiency 12b.SEER/EER: 13 - -
13. Heating system: 13a.Type: Heat Pum -
a.Type 13b.HSPF/COP/AFUE: 7.7
b.Efficiency
14. HVAC sizing calculation:attached 14. Yes El NoO --
15. Hot water system:
a Type 15a.Type: Electric
b.Efficiency 15b.EF:- .90 _-- --
I hereby certify that the plans and specifications covered by the calculation are in compliance with the Florida Review of plans and specifications covered by this calculation indicates compliance with the Florida
Energy Code. m Energy Cade.Before construction is completed,this building will be inspected for compliance in
Ryan B.Ellis 4/6/15 accordance with Section 553.908,F.S.
PREPARED BY: r DATE: � /�
: , / `
I hereby certify that this building is in compliance with the Florida Energy Code: CODE OFFICIALCl-15-15-1•J-/
OWNER AGENT: DATE: DATE: !
C.4 2010 FLORIDA BUILDING CODE-ENERGY CONSERVATION
ro ect Summa Job:
P
` - - wrightsoft 1 � Date: 3131115
Entire House By: M.Ellis
Energy Design Systems, Inc.
12132 Weatherwood Estates Dr W,Jacksonville,FL 32223 Phone:904-268-3670 Fax:904-268-3670 Email:eds.iaxaomail.comi
Project • •
For: Renovation N MUST BE
50 S Forrestal Cir,Atlantic Beach, FL FTHIS PLA
Notes: N JOB SITE FOR
EACH INSPECTION
Design Information
Weather: Mayport Ns, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 39 °F Outside db 92 °F
Inside db 70 °F Inside db 74 °F
Design TD 31 °F Design TD 18 °F
Daily range L
Relative humidity 50 %
Moisture difference 58 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 25308 Btuh Structure 21730 Btuh
Ducts 1913 Btuh Ducts 2553 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 27221 Btuh Use manufacturer's data n
Rate/swing multiplier 0.97
Infiltration Equipment sensible load 23578 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 1 (Average) Structure 1909 Btuh
Ducts 566 Btuh
Heating Cooling Central vent(0 cfm) 0 Btuh
Area (ft') 925 925 Equipment latent load 2475 Btuh
Volume (ft3) 7400 7400
Air changes/hour 0.61 0.23 Equipment total load 26053 Btuh
Equiv. AVF(cfm) 75 28 Req. total capacity at 0.80 SHR 2.5 ton
Heating Equipment Summary Cooling Equipment Summary
Make Grandaire, Nordyne Make Grandaire, Nordyne
Trade 13 SEER W SERIES R410A HP Trade 13 SEER W SERIES R410A HP
Model WCH3304GKB* Cond WCH3304GKB*
AHRI ref 5212998 Coil WAP*304A*
AHRI ref 5212998
Efficiency 7.7 HSPF Efficiency 11.0 EER, 13 SEER
Heating input Sensible cooling 20020 Btuh
Heating output 28600 Btuh @ 47°F Latent cooling 8580 Btuh
Temperature rise 27 °F Total cooling 28600 Btuh
Actual air flow 953 cfm Actual air flow 953 cfm
Air flow factor 0.035 cfm/Btuh Air flow factor 0.039 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.91
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2015-Apr-06 09:43:14
'r W rightSOft" Right-Suite®Universal 2015 15.0.00 RSU17457 Page 1
f�CGi ...I J\Renovation,50 S Forrestal Cir,Ali Bch.rup Calc=MJ8 Front Door faces: E
r
wri htsoft Duct System Summary Dae:
Entire House By:
JOB COPY
Project Information
For: Renovation
50 S Forrestal Cir,Atlantic Beach, FL EACH INSPE=CTION
Heating Cooling
External static pressure 0.50 in H2O 0.50 in H2O
Pressure losses 0 in H2O 0 in H2O
Available static pressure 0.50 in H2O 0.50 in H2O
Supply/return available pressure 0.385/0.115 in H2O 0.385/0.115 in H2O
Lowest friction rate 0.146 in/100ft 0.146 in/100ft
Actual air flow 1000 cfm 1000 cfm
Total effective length(TEL) 342 ft
SupplyDetail Table
Design I Htg Clg Design Diam H x W Duct Actual Ftg.Egv
Name (Btuh) (cfm) 1 (cfm) FR (in) (in) Mat] Ln (ft) Ln (ft) Trunk
Bath I h 2476 89 88 1 0.149 6.0 Ox 0 ShMt 13.0 245.0 st3
BedRo=2 c 2957 106 108 1 0.146 6.0 Ox 0 1 ShMt 1 13.0 1 250.0 st3
BedRoom3 c 3907 142 142 0.182 6.0 Ox 0 ShMt 22.0 190.0 st3
Dining I h 27231 981 97 10.1491 6.01 Ox 0 1 ShMt 1 14.0 1 245.0 1 st2 I
I Hallway-A I h 60081 2161 212 1 0.1821 7.01 Ox 0 1 ShMt 1 22.0 1 190.0 1 st2 I
I Kitchen I C 22401 811 82 1 0.1511 5.01 Ox 0 I ShMt 1 20.0 1 235.0 1 st2 I
1 LivingRoam I c 30251 1091 110 1 0.1561 6.01 Ox 0 I ShMt 1 22.0 1 225.0 1 st2 I
I MBath I c 4931 181 18 1 0.1491 4.01 Ox 0 1 ShMt 1 24.0 1 235.0 1 st3 I
Master 1 C 39071 1421 142 1 0.1551 7.01 Ox 0 ShMt 1 23.0 1 225.0 1 st3 1
SupplyDetail Table
Trunk Htg Clg Design Veloc Diam H x W Duct
Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk
st1 Peak AVF 1000 1000 0.146 815 15.0 0 x 0 ShtMetl
I st2 1 Peak AVF I 503 1 501 I 0.149 I 762 1 11.0 1 0 x 0 I ShtMetl st1 1
1 st3 1 Peak AVF 1 497 1 499 1 0.146 1 756 1 11.0 1 0 x 0 1 ShtMetl 1 st1 1
Bold/italic values have been manually overridden
t, ea 2015-Apr-06 09:43:30
ti wrlgl ltsOl t Right-Suite®Universal 2015 15.0.00 RSU17457 Pagel
ACO,.t.
.A D\Renovation,50 S Forrestal Cir,Atl Bch.rup Calc=MJS faces: E