50 Forrestal Cir 2015 FORMS 1111111111111 III.111111.III III 11111 IN FLORIDA BUILDING CODE,ENERGY CONSERVATION FORM 402.2010 Residential Building Thermal Envelope Approach ALL CLIMATE ZONES Scope:Compliance with Section 402 of the Florida Building Code,Energy Conservation.shall be demonstrateo by the use of Form 402 for single-and multiple-lmnily residences of three stories or less in height,additions to existing residential buildings,renovations to existing residential buildings,new heating,cooling,and water heating systems in existing buildings,as applicable.To comply,a building must meet or exceed all of the energy efficiency requirements on Table 402A and all appplicable mandatory requirements summarized in Table 402B of this form.If a building does not comply with this method or Alternate Form 402,it may still comply under Section 405 of theFlorida Building Code,Energy Conservation. PROJECT NAME: RenOVatlon BUILDER: 50 S Forrestal Cir ---- - - AND ADDRESS: .Atlantic Beach PERMITTING OFFICE. Atlantic Beach OWNER: PERMIT NO.: Me Ch-79 JURISDICTION NO.: 261100 General Instructions: 1.New construction which incorporates any of the followingg features cannot comply using this method:glass areas in excess of 20 percent of conditioned floor area,electric resistance heat and air handlers located 1n attics.Additions<600 sq.ft.,renovations and equipment changeeuts may comply by this method with exceptions given. 2.Fill in all the applicable spaces of the"To Be Installed"column on Table 402A with the information requested.All"To Be Installed"values must be equal to or mor required levels. M O -4 3.Complete page 1 based on the"To Be Installed"column information. 4.Read the requirements of Table 4028 and check each box to indicate your intent to comply with all applicable items. 5.Read,sign and date the"Prepared By"certification statement at the bottom of page 1.The owner or owners agent must also sign and date the form. Please Print OCK0 O 1. New cor Pim�y t S-C 0 n 1. Existing l7v� 5; U3 2. Single-f: t IF ) /jj 2_ Single-family ♦/Z� W 3. If multip y� �{J� / .vwu' -� 4. Is this a 'l '" f l `e -PC,a- S� 4. NO 5. Conditic 5, 925 Sq ft 6. Glass IV C1 Ie 0 M ;1. 6a. _ y' b. I ;ing existing 6b. _ �� windows 6c. No New Net sq.ft. 0 7. Percent �h a 7 Z f71 8. Floor ty ///��� ��/ a. 8a.R=_ _ sq.ft. -_ 8c.R= -sq.ft. `1 + , 8d.R= sq.ft. c. A �z Ae f�' ,�� [ "-/r''� � 8e.R= sq.ft.9. Wall tyl / / 7 q e a' 9a-1. R=_ sq.ft. -- 9a-2. R=_ --sq.ft. _----------- b.Adjacent: 1. Nlasonry(llo- tio�n�f-value) 9b-1. R= sq.ft. -_ 2. Wood frame(Insulation R-value) 9b-2. R= -sq.ft. 10. Ceiling type,area and insulation: a.Under attic(Insulation R-value) 10a.R= -sq.ft. _ b.Single assembly(Insulation R-value) 10b.R= _sq.ft. -_ 11. Air distribution system:Duct insulation,location,On a.Duct location,insulation 11a. R= 6 _ -- b.AHU location 11 b. c.Qn,Test report attached(<0.03:yes/no) 11 a-Test report attached? YesO Nod -_ 12. Cooling system: a Type 12a.Type: Central -- b.Efficiency 12b.SEER/EER: 13 - - 13. Heating system: 13a.Type: Heat Pum - a.Type 13b.HSPF/COP/AFUE: 7.7 b.Efficiency 14. HVAC sizing calculation:attached 14. Yes El NoO -- 15. Hot water system: a Type 15a.Type: Electric b.Efficiency 15b.EF:- .90 _-- -- I hereby certify that the plans and specifications covered by the calculation are in compliance with the Florida Review of plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. m Energy Cade.Before construction is completed,this building will be inspected for compliance in Ryan B.Ellis 4/6/15 accordance with Section 553.908,F.S. PREPARED BY: r DATE: � /� : , / ` I hereby certify that this building is in compliance with the Florida Energy Code: CODE OFFICIALCl-15-15-1•J-/ OWNER AGENT: DATE: DATE: ! C.4 2010 FLORIDA BUILDING CODE-ENERGY CONSERVATION ro ect Summa Job: P ` - - wrightsoft 1 � Date: 3131115 Entire House By: M.Ellis Energy Design Systems, Inc. 12132 Weatherwood Estates Dr W,Jacksonville,FL 32223 Phone:904-268-3670 Fax:904-268-3670 Email:eds.iaxaomail.comi Project • • For: Renovation N MUST BE 50 S Forrestal Cir,Atlantic Beach, FL FTHIS PLA Notes: N JOB SITE FOR EACH INSPECTION Design Information Weather: Mayport Ns, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 92 °F Inside db 70 °F Inside db 74 °F Design TD 31 °F Design TD 18 °F Daily range L Relative humidity 50 % Moisture difference 58 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 25308 Btuh Structure 21730 Btuh Ducts 1913 Btuh Ducts 2553 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 27221 Btuh Use manufacturer's data n Rate/swing multiplier 0.97 Infiltration Equipment sensible load 23578 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 1909 Btuh Ducts 566 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area (ft') 925 925 Equipment latent load 2475 Btuh Volume (ft3) 7400 7400 Air changes/hour 0.61 0.23 Equipment total load 26053 Btuh Equiv. AVF(cfm) 75 28 Req. total capacity at 0.80 SHR 2.5 ton Heating Equipment Summary Cooling Equipment Summary Make Grandaire, Nordyne Make Grandaire, Nordyne Trade 13 SEER W SERIES R410A HP Trade 13 SEER W SERIES R410A HP Model WCH3304GKB* Cond WCH3304GKB* AHRI ref 5212998 Coil WAP*304A* AHRI ref 5212998 Efficiency 7.7 HSPF Efficiency 11.0 EER, 13 SEER Heating input Sensible cooling 20020 Btuh Heating output 28600 Btuh @ 47°F Latent cooling 8580 Btuh Temperature rise 27 °F Total cooling 28600 Btuh Actual air flow 953 cfm Actual air flow 953 cfm Air flow factor 0.035 cfm/Btuh Air flow factor 0.039 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.91 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2015-Apr-06 09:43:14 'r W rightSOft" Right-Suite®Universal 2015 15.0.00 RSU17457 Page 1 f�CGi ...I J\Renovation,50 S Forrestal Cir,Ali Bch.rup Calc=MJ8 Front Door faces: E r wri htsoft Duct System Summary Dae: Entire House By: JOB COPY Project Information For: Renovation 50 S Forrestal Cir,Atlantic Beach, FL EACH INSPE=CTION Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.385/0.115 in H2O 0.385/0.115 in H2O Lowest friction rate 0.146 in/100ft 0.146 in/100ft Actual air flow 1000 cfm 1000 cfm Total effective length(TEL) 342 ft SupplyDetail Table Design I Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) 1 (cfm) FR (in) (in) Mat] Ln (ft) Ln (ft) Trunk Bath I h 2476 89 88 1 0.149 6.0 Ox 0 ShMt 13.0 245.0 st3 BedRo=2 c 2957 106 108 1 0.146 6.0 Ox 0 1 ShMt 1 13.0 1 250.0 st3 BedRoom3 c 3907 142 142 0.182 6.0 Ox 0 ShMt 22.0 190.0 st3 Dining I h 27231 981 97 10.1491 6.01 Ox 0 1 ShMt 1 14.0 1 245.0 1 st2 I I Hallway-A I h 60081 2161 212 1 0.1821 7.01 Ox 0 1 ShMt 1 22.0 1 190.0 1 st2 I I Kitchen I C 22401 811 82 1 0.1511 5.01 Ox 0 I ShMt 1 20.0 1 235.0 1 st2 I 1 LivingRoam I c 30251 1091 110 1 0.1561 6.01 Ox 0 I ShMt 1 22.0 1 225.0 1 st2 I I MBath I c 4931 181 18 1 0.1491 4.01 Ox 0 1 ShMt 1 24.0 1 235.0 1 st3 I Master 1 C 39071 1421 142 1 0.1551 7.01 Ox 0 ShMt 1 23.0 1 225.0 1 st3 1 SupplyDetail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st1 Peak AVF 1000 1000 0.146 815 15.0 0 x 0 ShtMetl I st2 1 Peak AVF I 503 1 501 I 0.149 I 762 1 11.0 1 0 x 0 I ShtMetl st1 1 1 st3 1 Peak AVF 1 497 1 499 1 0.146 1 756 1 11.0 1 0 x 0 1 ShtMetl 1 st1 1 Bold/italic values have been manually overridden t, ea 2015-Apr-06 09:43:30 ti wrlgl ltsOl t Right-Suite®Universal 2015 15.0.00 RSU17457 Pagel ACO,.t. .A D\Renovation,50 S Forrestal Cir,Atl Bch.rup Calc=MJS faces: E