500 CRUISER LN HVAC 2015 CITY OF ATLANTIC BEACH
.. _ 800 SEMINOLE ROAD
!� X ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
—r J519
MECHANICAL HVAC PERMIT
MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814
JOB INFORMATION:
Job ID: 15-MECH-972
Job Type: MECHANICAL HVAC ONLY
Description: 1 cu 1 ahu 3 tons
Estimated Value:
Issue Date: 4/27/2015
Expiration Date: 10/24/2015
PROPERTY ADDRESS:
Address: 500 CRUISER LN
RE Number: 170703-0316
PROPERTY OWNER:
Name: MASON, WALKER
Address: 500 CRUISER LN
GENERAL CONTRACTOR INFORMATION:
Name: DONOVAN HEATING &AIR
Address: 315 SIXTH AVENUE S QA WILLIAM J DONOVAN
Phone: - -
PERMIT INFORMATION: Sticker for overcurrent protection must be on A/C equipment prior to
inspection. Failure to comply will result in a failed inspection and reinspect fees. No
exceptions.
FEES:
Furnaces and Heating $24.00
AC and Refrigeration $24.00
State Mech DBPR Surcharge $2.00
State Mech DCA Surcharge $2.00
Trade Permit Base Fee $55.00
Total Payments: $107.00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904) 247-5826 Fax (904) 247-5845
10B ADDRESS: OO C C U lSe c Lcl a R 72Qa�3 PERMIT#
PROJECT VALUE $ 7 ARI# 7ZS REQUIRED
Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit Seer Ratin
Heat: Unit Quantity BTU's Per Unit REQUIRED
Duct Systems: Total CFM
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit 3 Seer Rating
Heat: Unit Quantity�— BTU's Per Unit gREQUIRED
Duct Systems: Total CFM �a.� _
FIRE PREVENTION 3 sets of plans)
Fire Sprinkler System Quantity (Requires
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
#Water Heaters Solar Collection Systems
Tanks (gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
tis application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name VNZ\,� Phone Number
Mechanical Company �' "� pi`C Office Phon `N F -31 SS t
�h V e �oyrl Cit5�e� tate fFL ZiP2�—aGO
Co. Address:
State Certification/Registration# �42L 1
License Holder(Print):
Notarized Signature of License Holder
Before me this 1-�L—day of A 20--LC, —
:�y' RICHARD TOMPKINS
' on#FF 040399
:..
Commission Signature of Notary Public
-g Expires July 29,2017
Bonded Ttm Troy Fain Mauanes 80038.&7010
Project Summary Job:
wri htsoft" Date: April 23,2015
9 Entire House By: Aaron Thacker
Donovan Heat &Air
315 6th Ave S,Jacksonville Beach,FL 32250 Phone:904-241-3785 Fax:904-241-3745 Email:aaron@donovanac.com Web:www.DonovanAC.com
Proiect In • rmation
For: Walker Mason
500 Cruiser Ln, Atlantic Beach, FL 32233
Notes:
Design Information
Weather: Jacksonville Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 39 °F Outside db 95 °F
Inside db 70 °F Inside db 75 °F
Design TD 31 °F Design TD 20 °F
Daily range L
Relative humidity 50 %
Moisture difference 53 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 26705 Btuh Structure 20836 Btuh
Ducts 4945 Btuh Ducts 4814 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 31649 Btuh Use manufacturer's data n
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 25651 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
0 Structure 1154 Btuh
Fireplaces Ducts 2066 Btuh
Heating Cooling Central vent (0 cfm) 0 Btuh
Area (ftz) 1040 1040 Equipment latent load 3220 Btuh
Volume (ft3) 8320 8320 28871 Btuh
Air changes/hour 0.45 0.23 Equipment total load
Equiv.AVF (cfm) 62 32 Req. total capacity at 0.70 SHR 3.1 ton
Heating Equipment Summary Cooling Equipment Summary
Make Tempstar Make Tempstar
Trade 15 SEER N SERIES R410A HP Trade 15 SEER N SERIES R410A HP
Model NXH536GKA" Cond NXH536GKA'
AHRI ref no.3670858 Coil FXM4X36"A"
AHRI ref no.3670858
Efficiency 8.7 HSPF Efficiency 12.5 EER, 15 SEER
Heating input Sensible cooling 24360 Btuh
Heating output 35400 Btuh @ 47°F Latent cooling 10440 Btuh
Temperature rise 28 °F Total cooling 34800 Btuh
Actual air flow 1160 cfm Actual air flow . cfm
Air flow factor 0.037 cfm/Btuh Air flow factor 0.045 045 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.89
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
2015-Apr-27 07:15:46
+ W rightSoft" Pight-Suite®Universal 8.0.24 RSU05995 Pagel
ACCP. C:\Users\Owner\Documents\W rightsoft HVAC\Bogus 3 ton.rup Calc=MJ8 Front Door faces:W