1931 BEACH AVE 2015 HVAC S
11SSCITY OF ATLANTIC BEACH
1
f 800 SEMINOLE ROAD
J - ATLANTIC BEACH, FL 32233
INSPECTION PHONE LINE 247-5814
��J13a�r
MECHANICAL HVAC PERMIT
MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814
JOB INFORMATION:
Job ID: 15-MECH-974
Job Type: MECHANICAL HVAC ONLY
Description: 1 cu 1 ahu 1.5 tons
Estimated Value:
Issue Date: 4/27/2015
Expiration Date: 10/24/2015
PROPERTY ADDRESS:
Address: 1931 BEACH AVE
RE Number: 169692-0000
PROPERTY OWNER:
Name: LEE, STEVEN Y
Address: 1931 BEACH AVE
GENERAL CONTRACTOR INFORMATION:
Name: DONOVAN HEATING & AIR
Address: 315 SIXTH AVENUE S QA WILLIAM J DO
NOVAN
Phone: - -
PERMIT INFORMATION: Sticker for overcurrent protection must be on A/C equipment prior to
inspection. Failure to comply will result in a failed inspection and reinspect fees. No
exceptions.
FEES:
Furnaces and Heating $24.00
AC and Refrigeration $12.00
State Mech DBPR Surcharge $2.00
State Mech DCA Surcharge $2.00
Trade Permit Base Fee $55.00
Total Payments: $95.00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND 771E FLORIDA
BUILDING CODES.
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904) 247-5''\826 Fax (904) 247-5845
IOB ADDRESS: 1,. J �(� Al�� H L ��`� PERMIT#
PROJECT VALUE $ 33 ARI# �9 j 311 'jr REQUIRED
Air Handling Equipment Only Air Handling Unit & Condenser Condenser Only
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity I Tons Per Unit /�
Heat: Unit Quantity 1 BTU's Per Unit j�o — Seer Rating
Duct Systems: Total CFM 9= REQUIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace Qty Automobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
# Water Heaters Solar Collection Systems
Tanks(gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read
its application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
ot. The permit does not give authority to violate the provisions of any other state or local law regulation construction or the performance of construction.
Property Owners Name J _«, Phone Number
Mechanical Company `�a30.� �re_ L �i C Office Phone `113 ax
Co. Address: 0V2. City� tt4atateI Zip3'a�
,
License Holder(Print): (��1 �1��0r, e `ave�� State Certification/Registration#IM L�
Notarized Signature of License Holder /�
Before me this day of 20
,1 ryyk; RICHARD TOMPKINS
.: Commission#FF 040399 Signature of Not Public
. Expires July 29,2017 $� '
'f p,. o" Boded Thm Troy Fain Mtum a 9DD3W016
Job:
wri ht5oft Project Summary Date: 4/20/15
9 Entire House By: Brandon Zaharie
Donovan Heat & Air
315 6th ave south,Jacksonville Beach,FL 32250 Phone: 241-3785 Email:brandon@donovanac.com
Project • •
For: Lee
1931 Beach Ave, Atlantic Beach, FL 32233
Notes:
Design Information
Weather: Jacksonville Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 39 °F Outside db 95 °F
Inside db 68 °F Inside db 75 °F
Design TD 29 °F Design TD 20 °F
Daily range L
Relative humidity 50 %
Moisture difference 53 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 9277 Btuh Structure 10200 Btuh
Ducts 1227 Btuh Ducts 1383 Btuh
Central vent (28 cfm) 894 Btuh Central vent (28 cfm) 617 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 11397 Btuh Use manufacturer's data n
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 12200 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction qualityAverage 1434 Btuh
Fireplaces 1 (Average) Structure
Ducts 293 Btuh
Heating Cooling Central vent (28 cfm) 1015 Btuh
Area W 480 480 Equipment latent load 2741 Btuh
Volume�ft3) 4320 4320
Air Changes/hour 0.89 0.32 Equipment total load 14941 Btuh
Equiv.AVF (cfm) 64 23 Req. total capacity at 0.70 SHR 1.5 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade Trade
Model 25HCD318 Cond 25HCD318
ARI ref no. 7913918 Coil FX4DNF019
ARI ref no. 7913918 15 SEER
Efficiency 7.8 HSPF Efficiency 10779 Btuh
Heating input Sensible cooling 4620 Btuh
Heating output 15323 Btuh @ 47°F Latent cooling 15399 Btuh
Temperature rise 27 °F Total cooling 513 cfm
Actual air flow 513 cfm Actual air flow 0044 cfm/Btuh
Air flow factor 0.049 cfm/Btuh Air flow factor 0 in H2O
Static pressure 0 in H2O Static pressure
Space thermostat Load sensible heat ratio 0.82
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
�- +}+ wrightsoft Right-Suite®Universal 7.1.01 RSU05996 2015-Apr-20 14:18:59
ACCA C:\Users\Sales\Documents\Wrightsoft HVAC\1.5 TON.rup Calc=MJ8 Orientation=N Page 1