Loading...
1021 ATL #997 HIBBETTS RESPONSIBILITY SCHEDULE DRAWING I N G INDEX REV DATE J LANDLORD HIBBETT HIBBETT HIBBETT Q U. LANDLORD HIBBETT QC w _ _j _j T1 TITLE SHEET 04/02/15 > fA J f/) J Cl) _I � J Ln J U) J Z Z Z Z Z Z ITEM: ILLz REMARK ITEM: REMARK Ls1 LIFE SAFETY PLAN 04/02/15 z z z �. z z ,� z RESPONSIBILITY KEY: • NEW ITEM TO BE PROVIDED AND INSTALLED O EXISTING ITEM,VERIFY PLACEMENT AND CONDITION. IF ITEM IS MISSING OR DAMAGED,PROVIDE AND INSTALL NEW ITEM J /� 01 GENERAL REQUIREMENTS 09 \� J_ U 1 LANDLORD PERMITS 29 FIRE STRIPE FLOOR PAINTING N/A D1 DEMOLITION PLANS UJ 2 LANDLORD PERMIT FEES 30 ELECTRICAL STRIPE FLOOR PAINTING \ M 3 LANDLORD CERTIFICATE OF OCCUPANCY 31 PAINTING(GENERAL) • / W 4 LANDLORD WARRANTY 32 PAINTING(TOILET ROOM) Z 5 TENANT PERMITS 33 PAINTING(CORRIDOR) A1:0 DIVENSIONED FLOOR PLAN 0 04/02/15 U 6 TENANT PERMIT FEES 10 SPECIALTIES 7 TENANT CERTIFICATE OF OCCUPANCY 1 TOILET ROOM GRAB BARS SEE ACC.S HED.ON SHEET A-2.2 Al.1 DOOR SCHEDULE AND DETAILS J 8 LANDLORD CLOSEOUT DOCUMENTS 2 TOILET ROOM MIRRORS SEE ACC.S HED.ON SHEET A-2.2 A2:"0 FIXTURE PLAN AND DETAILS � 04/02/15 z z 9 TENANT GC CLOSEOUT DOCUMENTS • 3 SINGLE ROLL PAPER TOWEL HOLDER • ® SEE ACC.S HED.ON SHEETA-2.2 10 TENANT WARRANTY 4 SINGLE ROLL TISSUE HOLDER SEE ACC.S HED.ON SHEET A-2.2 A2.1 INTERIOR ELEVATIONS a M Q Q � 11 MECHANICAL AIR BALANCE 5 TOILET ROOM SIGNAGE SEE ACC.S HED.ON SHEET A-2.2 A2.2 INTERIOR DETAILS �i 04/02/15 ,� 12 ASBESTOS REMOVAL 6 FITTING ROOM MIRRORS r 13 LANDLORD TO VERIFY EXISTING CONDITIONS 7 FITTING ROOM HOOKS ► "�" E �" M "�" },,,�', L "� fly C� Q J', (" 1 TM A2.3 NOT USED ON THIS PROJECT I"� ` 4 14 TENANT TO VERIFY EXISTING CONDITIONS 8 WALUFLOOR DOOR STOP(S) SEE ACC.S HED.ON SHEETA-2,2 ! 4. +ti.7 i 1 t 1 i f"1 (- A [ Y LJ y 02 EXISTING CONDITIONS 9 CLEAR SILICONE CAULK TOILET ROOM MIRROR ® A2.4 NOTUSED ON THIS PROJECT Q (� 1 DEMOLITION 10 CLEAR SILICONE CAULK TOILET ROOM COVE BASE A3 FLOOR FINISH PLAN � 04/02/15 2 REMOVAL OF PREVIOUS TEANANTS SIGNAGE 11 CLEAR SILICONE CAULK FITTING ROOM MIRROR 3 REPAIR AND REPAINT STOREFRONT DAMAGE FROM REMOVAL OF SIGN 12 CLEAR SILICONE CAULK FITTING ROOM BENCH • A4 REFECTED CEILING PLAN : :' 4 TRASH REMOVAL(LANDLORD'S WORK) 13 CLEAR SILICONE CAULK FITTING ROOM COVE BASE 5 TRASH REMOVAL(TENANT'S WORK) 14 SEAUCLOSE OFF STOREFRONT DOOR(S) PER SHEE f A1.1ui d 6 FINAL CLEANUP(LANDLORD'S WORK) 15 SEAUCLOSE OFF REAR EXIT DOOR(S) PER SHEE f A1.1 7 FINAL CLEANUP(TENANT'S WORK BEFORE TURNOVER 16 FIRE EXTINGUISHERS 3 MINIMUM OR PER CODE # 1294 M1 HVAC PLAN & NOTES 1 04/02/15 ( ) ( ) 8 STOREFRONT CLEANING INSIDE 17 SERVICE/TAG FIRE EXTINGUISHERS uj M2` HVAC SCHEDULES & DETAILS cr E E 9 STOREFRONT CLEANING OUTSIDE 18 SHELF STANDARDS CONDUIT&CONNECTION FROM UTILITY 19 STOCKROOM SHEVLVING 0- 10 METER TO TENANT SPACE d 11 TELEPHONE CONDUIT FROM DEMARK INTO 20 SIGNS(ILLUMINATED) DEMISED SPACE 21 PYLON SIGN CABINET$PANEL E1 ` ELECT RICAL POWER PLAN & DETAILS 04/02/15 uj0 o BRING PHONE SERVICE FROM DEMARK 12 22 VINYL LETTERS ON BACK DOOR ATLANTIC VILLAGE INTO DEMISED SPACE E2, LIGHTING PLAN � ~ 0 03 CONCRETE 23 VINYL ADDRESS NUMBERS AT FRONT ENTRY 1 CONCRETE SLAB EXISTING 24 WHITE OPAQUE VINYL FILM N/A E3 ELECTRICAL PANEL SCHEDULES & DETAILS 04/02/15 _ 2 REPAIR EXISTING DAMAGED SLAB • 25 BLACK VINYL WINDOW GRAPHICS N/A 997 ATLANTIC BLVD 1 Q 3 CONCRETE SEALER STOCK AREA$CORRIDOR 26 SIGN HOLDER TRACK E4 TELEPHONE & DATA DETAILS 4 CUT SLAB FOR ELECTRICAL AT CASH&WRAP 11 EQUIPMENT U I PM E NT 5 CUT SLAB FOR ELECTRICAL AT SENSORMATIC 1 GASH&WRAP COUNTER(PREFAB) f-4 O 05 METALS (ALL STUDS TO BE METAL) 2 2X4 PLEXI CEILING PANELS ATLANTI C BEACH , F 32233 P1 PLUMBING SCHEDULE & DETAILS 04/02/15 W W M 1 DEMISING WALL STUDS EXISTING 3 2X2 PLEXI CEILING BUBBLES ( Q 0) 2 STOCK ROOM WALL STUDS 4 TELEPHONE BACKBOARD Q 137 N CIO�a� 3 FITTING ROOM WALL STUDS • • 5 TELEPHONE JUNCTION BLOCKS ' Z Q = 4 TOILET ROOM WALL STUDS 6 TELEPHONE JACKS `' g = M 5 CORRIDOR WALL STUDS 7 ENERGY MANAGEMENT SYSTEM(EMS) ' f (j 6 FURRING/DISPLAY WALL STUDS ® . �5 MECHANICAL ��. - ICJ I 1 W Z a � Ce \/ CODE REVIEW GRAPHICS SYMBOLS 7 COLUMN WRAP STUDS 1 'HVAC UNIT EXISTING SITE LOCATION PLAN 8 METAL ACCESS PANEL FOR EXTERIOR SIGN(S) 2 HVAC UNIT SERVICE APR 07 � N m O 3 ROOF,CUTS&CURBS O EXISTING 1 FURRING STRIPS 4 DUCT WORK,DIFFUSERS,&GRILLES CODES: _ 2 VERTICAL SHOEWALL FURRING STRIPS 5 THERMOSTAT(S),SENSOR(S),&RECEIVER(S) SEE SHEE-M1 FOR DETAILS 3 INTERIOR TRIM • 6` CEILING MOUNTED UNIT HEATER N/A BUILDING: FLORIDA BUILDING CODE 2010 4 PLYWOOD BACKING FOR EXTERIOR SIGN(S) 7 TOLLET(S) SEE PLUMB. SCHED.ON SHEET P1 DETAIL NUMBER C7 C7 u w } ❑ w F- 5 FITTING ROOM BENCH 8 LAVATORIES) _ SEE PLUMB. CHED.ON SHEET P1 PLUMBING: FLORIDA PLUMBING CODE 2010 3 `p F- � OZ O W O a- w ZZOLYZW WWZ LL LL w LU 1 L j 6 SECURITY PLYWOOD WALL COVERING • ® INSIDE OF EXTERIOR STOCK ROOM WALLS 9 INS1-ANTANEOUS WATER HEATER(S) SEE PLUMB. CHED.ON SHEET P1 MECHANICAL: FLORIDA MECHANICAL CODE 2010 A100 W W w H 00 0 (9 m °- LL Z 7 SCREWS FOR UPRIGHTS STOCK AREASHELVESBSALESAREAUPRIGHT$ 10 FLOOR DRAIN(S) N/A LU SHEET NUMBER _j Z Iw— w w W z = W 11 MOPJUTILITY SINK RELOCATE 07 THERMAL & MOISTURE PROTECTION ELECTRICAL: NATIONAL ELECTRICAL CODE 2008 Q — �- m Q T ❑ 1 6.25" R19 BATT INSULATION ABOVE CEILING N/A ,3 12 ELECTRIC ACCESSIBLE WATER COOLER N/A 1 CALLOUT A100 W w LU O m �— p 2 FIREPROOFING OF ALL RATED PARTITIONS „ PER LOCAL CODE REQUIREMENT 13 TOILET ROOM EXHAUST FAN(S) SEE PLUMB. 'CHED.ON SHEET P1 w zz — 08 OPENINGS _:, ` (REFER TO DOOR SCHEDULE) 14 VENTPIPING m W ¢ O g w Z C7 O LU U FIRE: FLORIDA FIRE PREVENTION CODE 2012 U U m U 1 STOREFRONT GLASS EXISTING 15 BACKFLOW PREVENTION DEVICE 3 W W z O Z W LL 2 STOREFRONT ENTRANCE DOORS EXISTING 16 SPRINKLER SYSTEM N/A SECTION CUT x O Q z ❑ C7 w z ( } ACCESSIBILITY: FLORIDA ACCESSIBILITY CODE 2012 A100 r >```;;; 3 REAR EXIT DOOR 4 17 TEST SPRINKLER SYSTEM N/A r� U w ❑ O Z J O m Z Z O Y 4 TOILET ROOM DOOR 16 ELECTRICAL LJJ } o } O 3 . li s t15 w — U _ ❑ 5 TOILET ROOM DOOR JAMB ELECTRICAL SERVICE DISTRIBUTION ELEVATION A100 I ="x 4e �(" w Q W W Z F- m 6 STOCK ROOM DOOR 1 ELECTRICAL PANELS&TRANSFORMERS EXISTING p :jaW 2 Al RMO Z 7 STOCK ROOM DOORJAMB 2 ELECTRICAL SERVICE,METERS,ETC... EXISTING ,3 £ a. Z = u❑1 — /�/ T m LL LL i mw 8 FITTING ROOM DOOR 3 ELECTRICAL BREAKERS OFFICE Q — O Q W d Q = p Z _ ROOM NUMBERy m � � zwpo H 100 2>� , vailab ���'� p > ZWOC7F- WZF1 0 9 FITTING ROOM DOORJAMB 4 LOCKOUTS ON BREAKERS j °) k g , tt „ ; �y Z I.- Z W O W LL = C7 W 10 CORRIDOR DOOR(S) 5 TYPED DIRECTORY FOR SERVICE PANELS CONSTRUCTION TYPE: £ r W Z (p _ w U U U W 11 CORRIDOR DOOR JAMB(S) COMMUNICATIONS KEY NOTE 2 O - 3 1— o d 12 SECURITY GATE N/A 6 TELEPHONE WIRING TYPE II-B -_ W U (n Q (n fn Z F- W 00 HARDWARE SEE SHEET CONTRACTO TO HAVE PHONES UNPROTECTED ^ Z (n Z (n z ❑ W O rn LL 13 DOOR WINDOW TAG 2❑ �i ids Nail; I�,,2 I�, r'�" s , � Lu � Q Q O m W U U ZO p 2 7 MAKE PHONE JACKS LIVE WORKING P OPERLY2 WEEKS a # f (u ® NON-SPRINKLED >21 MiatlWAA11 .1 1 U O 14 KENSTAN CYLINDERS PRIOR TOT INOVER "= ;� ! ❑ V O� Z Z Z C'f Cop U Z U K RECEPTACLES SECURITY CONNECTIONS&SPECIAL SYSTEMS `.'x f": 3 :' ) I"' (n U O O m — W �'- O 15 ENTRANCE DOOR SECURITY BARS PARTITION TAG 2 a �' A v a hi a, t � £ z ❑ O USE GROUP CLASSIFICATION: �: -� = ��-.� p� � F. - Z p � - - � � � � ° � 16 REMOVABLE MULLION N/A 8 OUTLETS&OUTLET COVERS #is L,(�I} ub 4,�>,,, 9 CASH$WRAP OUTLETS 11 t esl a£ 3;8 f 7, O Z Z Z m 0r — O_ 17 ALARM LOCK DOOR TAG O ." O O O O m D O W W H X X 18 BURGLAR BAR 10 3RD CONDUIT w/PULL STRINGS MERCANTILE GROUP Mw (0a. 11 OUTLET FOR SECURITY ON PHONE BOARD a� �� ; � ��. (:,,�(� � �� U � ❑ U U U 2 cn � � 19 HURRICANE PROTECTION PANELS OCCUPANCY CLASSIFICATION: FINISH ITEMS '. II .f i In ` $ 12 SECURITY RECEPTACLES 13'-0"AFF(3) o h x �; : $ }. 1 r;: s :xi :F.: A 09 FINISHES _ f' z g I ."rir s� >__. 1 CEILING GRID EXISTING-EXTEND AS SHOWN 13 SENSORMATIC k« S" I a ,:, - - �. if : ( SII; I:�>I ''.�. '>>Kv TBUILDING MERCANTILE GROUP EQUIPMENTTAG 2 ,R, © COPYRIGHT 2014 EPLACEASNEEDED 14 SENSORMATIC JUNCTION BOX O 2 CEILING TILE EXISTING-REPLACE �n, . TENANT GROUP C2 MERCANTILE Ma F HIBBETT SPORTING GOODS N 1 $$Ilxl:, .x�) ,1 Fi h z :: , INC 3 (2)FULL BUNDLES OF CEILING TILES N/A 15 LINE CONDITIONER FOR SENSORMATIC SYSTEM , n�. s• t.x ELEVATION BENCHMARK n �,.< . EXISTING 16 DOOR BUZZER s.£ , FIRE SUPPRESSION SYSTEM. { ' REv1sloNs: 4 GYPSUM BOARD CEILINGj jj k 1 '°#"s �.l � ... 3.:, ` -:° ".... (�...>. .JF `•n .a'1' .F-:.>X' :..y may : '�` ..:.. ��.. 5 DEMISING WALL GYPSUM BOARD EXISTING-REPAIR AS NEEDE 17 RECEPTACLES AT CEILING ` REVISION TAG , 1 BD COMMENTS 04/02/15 6 STOCK ROOM WALL GYPSUM BOARD SIGN(S)CONNECTION(S) v% YES ❑ NO ® .`" � I # W. 7 FITTING ROOM WALL GYPSUM BOARD 18 SIGNAGE HOOKUP F L F a n i i .: d ££ ( f 8 TOILET ROOM WALL GYPSUM BOARD 19 SIGN CIRCUITS • — LEASE LINE 1.� w£1 :n,,��h, GYPSUM BOARD 20 ATOMIC SIGN TIMER ) g OCCUPANCY LOADS. a= 9 CORRIDORWALLG ,.: .. - �� �� :' a'; � ' ,.Y�, <.�'` 8 :. <:F$ 1X:. «;.:F .� .�.1:. .. .. Y'o• `".._.. ;<'diF>� sx ,'n fx'.i.IT.` k :":.' 10 FURRING/DISPLAY WALL GYPSUM BOARD LIGHTING SALES FLOOR 3537 SQ FT DIVIDED _ - >•;. � .<> P ��x 21 LIGHT BULBS — EXISTING DEMISING PARTITION 11 COLUMN GYPSUM BOARD _ - BY 30 — 118 J GOGLIA 12 SLATWALL 22 2 FULL CASES OF LIGHT BULBS N/A STOCK RM/TOILETS 1428 SQ FT DIVIDED rrECT,NCARB,RDI " to ARCH 13 CARPET TILES NEW DEMISING PARTITION � z) � .£` 23 SALES AREA LIGHT FIXTURES BY 300 = 5 i rla; ,-:5 1950 CRAIG ROAD,SUITE 300 ST.LOUIS,MO 63146 14 CARPET TILE TACTILES 24 STOCK ROOM LIGHT FIXTURES TOTAL: 123 OCCUPANTS " PH(314)415 2400 FAX(314)415 2300 wwwsrcvcom 15 REDUCER STRIP FOR CARPET TO VINYL PLANK 25 FITTING ROOM LIGHT FIXTURES REDUCER STRIP FOR CARPET TO SLAB EXISTING PARTITION 16 RED 19 ( OI ar 26 TOILET ROOM LIGHT FIXTURES SQUARE FOOTAGE. .. 17 VINYL PLANK FLOORING . 27 CORRIDOR LIGHT FIXTURES _ a�t` 18 VINYL PLANK FLOORING ADHESIVE 28 TRACK LIGHTING SALES FLOOR 3490 SQ FT NEW PARTITIONf 19 ENTRANCE MAT 29 EXIT LIGHTING STOCK ROOM 1298 SQ FT PARTITION OR MATERIAL TO REVIEWED FOR CODE COMPLIANCE 20 ENTRANCE MAT ADHESIVE TOILET ROOMS 130 5Q FT — ——— — —— r TOILET ROOM VINYL COMPOSITION TILE CT 30 EMERGENCY LIGHTING ( ) 21 (VCT) FITTING ROOM 47 SQ FT — — —— — — — CITE'OF ATLANTIC BEACH — BE DEMOLISHED 31 MOTION SENSORS H r E• '' ( ` a �' ' 22 TOILET ROOM VCT ADHESIVE 32 LIGHTING CONTACTORS SEE PERMITS FOR ADDITIONAL NEW FURRING PARTITION 23 COVE BASE IN FITTING ROOM 33 LED OPEN SIGN N/A TOTAL LEASE: 4965 SQ FT (SALES AREA} REQUIRFAI�:NT;, D CONDITION$ 24 COVE BASE ADHESIVE IN FITTING ROOM -- ADDITIONAL ITEMS nEviEweD 1 25 FRP IN TOILET ROOM TO 48"AFF ON ALL WALLS Aa 26 FRP ADHESIVE IN TOILET ROOM LEVEL OF ALTERATION: L4L16 - 27 COVE BASE IN CORRIDOR LEVEL 2 ALTERATION 28 COVE BASE ADHESIVE IN CORRIDOR . • 150142 LANDLORD PLAN REVIEW MALL MANAGER OWNER PROJECT INFORMATION HIBBETT CONSTRUCTION DEPARTMENT �. TITLE SHEET Equity One City of Atlantic Beach Building Department Equity One HIBBETT SPORTING GOODS, INC LOCATION: # 1294 t DIR. OF CONSTRUCTION: JASON BREWER DIR. OF FACILITIES&DESIGN:JUSTIN FARR �-�;' 10601 San Jose Blvd 800 Seminole 10601 San Jose Blvd 2700 MILAN COURT STORE#: 1294 PROJECT MANAGER: NINA GRAY SENIOR DESIGN ANALYST: TIM MIZE d'' DATE: FEBRUARY 2015 _ Jacksonville, FL 32257 Atlantic Beach, FL 32233 Jacksonville, FL 32257 BIRMINGHAM, AL 35211 DRAWN BY: LCP PROJECT MANAGER RYAN LOVE DESIGN ANALYST: LAURA PHILLIPS SHEET Contact: Kevin Hollenbeck Contact: Shirley Graham Contact: Kevin Hollenbeck CONTACT HIBBETT CONSTRUCTION DEPT. PROJECT MANAGER CHRIS CASTLEBERRY DESIGN ANALYST: AMANDA KEITH Ph: 904-292-2222 Ph: 904-247-5826 Ph: 904-292-2222 @ (205) 942-4292; FAX: (205) 912-7310 ISSUE DATE: FEBRUARY 23, 2015 PROJECT MANAGER JEREMY BROWN CAD SPECIALIST: BRITTANY GRESHAM T� l NOTE: ACCESSIBILITY SIGN J GRAB BAR IS TO MEET ALL FEDERAL, ANSI APPROVED E.S. PLASTIC NEMA RATED STATE,&LOCAL CODE REQUIREMENTS. SELF EXTINGUISHING,WHITE RAISED CONSTRUCTION TYPE: Q GRAPHICS ON BLUE BACKGROUND,ADHESIVE MOUNTED TYPE II-B > ^ 6" UNPROTECTED 0 4'-6" MIN NON-SPRINKLED RAISED TLT SYMBOL 3'-6" MIN 12" 17"-25" 0 TO MATCH ROOM W v SD HIBBETT G.C.TO RAISED ACCESSIBILITY USE GROUP CLASSIFICATION: 40" 5"� 36" CAULK AROUND INSTALL CLEARR1 \ SYMBOL SALES AREA MERCANTILE GROUP M v R \� MIRROR " TH RP 00 STOCK ROOM STORAGE GROUP S-1 �' �� GB3 RP 1 INSULATE ALL -8" MIN afs���00 RAISED TEXT ¢ REQ'D SEPARATION NON > c R1 TH EXPOSED PIPE GRADE 2 BRAILLED \ co IQ CHARACTERS 9" 9" GB GB1 GB1 OCCUPANCY CLASSIFICATION: 4' MAX 1. � � ��'/ BUILDING MERCANTILE GROUP M Q 8" = _ I--. --ao ��' TENANT GROUP C2 MERCANTILE J 00 TP - N - - : N - I _ : I NOTE:ALL SIGNAGE SHALL CONFORM WITH ca o i _ v z r . l FI Z � . _ v ADA ACCESSIBILITY GUIDELINES, INCLUDING - M M � I: � : � : � O co � Z I: j Z _ I BUT NOT LIMITED*1'0 PROPORTION,COLOR i' g WHEN INSTALLED RE SUPPRESSION SYSTEM: i- -1; . . I CONTRAST,AND RELIEF AND GRADE 2 BRAILLE i' ON WALL SURFACE e- : : : : : : : N / REQUIREMENTS. YES ❑ NO 17" 15" 60"CLEAR 30"CLEAR 6" MAX 11" MIN OCCUPANCY C PA N 18"x18" CU NCY LOADS: CLEAR FLOOR 60"CLEAR 48"CLEAR FLOOR CLEARANCES SALES FLOOR 3537 SQ FT DIVIDED CAN OVERLAP BY 30 = 118 TOILET SIDE ELEVATION TOILET & LAV FRONT ELEVATION LAV SIDE ELEVATION DOOR SIGNAGE DETAILS DOOR SIGNAGE ELEVATIONS FIRE EXTINGUISHER STOCK RM/TOILETS 1428 SQ FT DIVIDED DETAILS _ BY 300 = 5 2 HANDICAPPED TOILET ROOM ELEVATIONS AND DETAILS TOTAL: 123 OCCUPANTS w LS-1 SCALE: 3/16" = 1'-0" (TYPICAL) SQUARE FOOTAGE: } � Q w MENS WOMENS SALES FLOOR 3490 SQ FT �' � TLT ROOM TLT ROOM STOCK ROOM 1298 SQ FT a 1 O3 1 O2 FIRE EXTINGUISHER IS TO BE TOILET ROOM 47 SQ FT0 INSTALLED ON INSIDE FACE OF TOTAL TRAVEL DI TANCE FITTING ROOM 47 SQ FT w CASH&WRAP COUNTER ENTRANCE TO EXIT= 106'-0" O O (AFTER FIXTURE DELIVERY) z TOTAL LEASE: 4965 SQ FT � H zLu 0 4 4 3 4 4 4 4 3 4 4 \.. .::.:.........�.;:::: I 1 . r::::::: I TOTAL OCCUPANT LOAD: 123 OCCUPANTS Q { ' .............1 ::::::;_ I::::::: ::::I EGRESS THRU FRONT ENTRANCE: 123/2=62 OCCUPANTS +� r I :.:1.. r .-..--.-i ;. +--I O . . .............. ....... ... . ... Ln -------- , EGRESS CAPACITY: w F M I d' 1-HR RATED � J � cV EXIT LIGHT I M PARTITION FE O= Q w TYP 1-HR RATED . FRONT ENTRANCE: 36"/.20= 180 OCCUPANTS ( ) U m REAR EXIT DOOR: 36"/.20= 180 OCCUPANTS z Q m DOOR ASSEMBLY = rn I 4'-10" wIN, z Q I NOTE: �-I F- o 64 FIRE I - M, REAR EXITS EQUIPPED WITH PANIC HARDWARE 4 0 ZO EXTINGUISHER FE �� d N m U @J (NP) 77'-4" - CORRIDOR 3; 41 1X4 - - - - - - - - - - - - - ~( - 1-HR RATED o 1 O5 PARTITION i Y > C7 C7 IL w >. ° w 1- co HR RATED i _� z zz0Xz -j Xwz 1 .�, LIFE SAFETY PLAN KEY cn Loo w rnl O I= � z0Q � ° oma O DOOR ASSEMBLY I z X X oo O O CoILL z w ° ° - ° wa. �' J Z I— W W w Z Z W ° m0 x X I }' 1� NON-SPRINKLED SPACE Ip cn Q � Q z ° I I Q L}iU � � JzO I v z -- v a m w I ® CEILING MOUNTED EXIT LIGHT cn W a 0 w Z 0 p w V x x x x x ' 4 CC > wm m0Z L,f.. wx > 0 () = za0 � - tl cn S�. LLNLL f FE cn FIRE EXTINGUISHER OW ~ (n 0 I- z z z Lu z I i d Z Fw- ° zW J0 � 0f= 0 x x x x -------- 1-HR RATED FIRE PARTITION I'— Q w z O 00 X )( c- - I O W I W O ° If w H ~ Z w z N .- ' c� z �' -' CnJW ° WO Uma o 1 00 ° 0Lu p � = O v v v � cn - 2zW (- STOCK AREA x x x x x I t N 0 > zcnoc� ° o wo � z X XF— WZUZ F- VI— Yw 101 N : -may zR689 Z) 00 SALES AREA i _ ° _ _ _ � Qx � w o �, a O v v v v v DIRECTION OF TRAVEL V Z °LU W Q cn z O x W U_ 2 v v X x X X X i 1OO I DISTANCE TO EXIT o � < U00° � � ai000 :. N I \59'-0" 101'-0" zcn () oo � Z � o ° u- 00 I - - - - - - - z wl- � PP: W � OhH v v v v , 1-HR RATED I - - - O rO OOOLL' � Yw O � Uo I PATH OF EGRESS � w W �- wx Of V � ° () ( () = cn � > xfnwml.. x x x x PARTITION ; zzzmmo � da ,LO I 3 I N T- v v v v v I © COPYRIGHT 2014 x x x x x 19'-0" _ _ _ _ _ _ _ _ I r ( I HIBBETT SPORTING GOODS, INC h IMPORTANT NOTE: REVISIONS: I v v v v v � ; X X X X x I 1 BD COMMENTS 04/02/15 v r G.C.TO PROVIDE AND INSTALL EXIT DOOR x I , TACTILE SIGNAGE(BRAILLE)PER NFPA 7.10.1.3 N x x x x x N M' `` FREDERICK J. GOGLIA ARCHrrECT,NCARB,RDI 1950 CRAIG ROAD,SUITE 300 ST.LOUIS,MO 63146 v v \ 581-011 PH.(314)415-2400 FAX(314)415-2300 www.ercvcom m FE 1-HR RATED I DOOR ASSEMBLY r �; , � � y�. " ` ��} V -- A I w 0 Mi \ ,u- ----- r� \ r.._ ......::.I 1-HR RATED DOOR ASSEMBLY 4 4 4 4 4 4 3 4 4 3 4 4 JL�] �`s --} 150142 ------- — — — — — — — -° — ------------------- — — — — — - - -- - - - — — ---------- - ------------------- `', LIFE SAFETY PLAN s / LOCATION: #$ 1294 FITTING DATE: FEBRUARY 2015 1 LIFE SAFETY PLAN ROOM SHEET LS-1 SCALE: 3/16" = V-0" 104 10 11 DEMO KEY NOTES --� l� J II II i - , I 1. DEMO ALL PARTITIONS AS INDICATED IN THEIR ENTIRETY UNLESS NOTED OTHERWISE(U.N.O.). PROTECT ADJACENT CONSTRUCTION TO REMAIN. w I II > 8 i I I 1A. DEMO EXISTING DEMISING WALLS BETWEEN SPACES UP TO 9'-8"A.F,F AS INDICATED. PREPARE REMAINING WALL TO CREATE BULKHEAD SOFFIT. SEE A4 FOR NEW SOFFIT DETAILS. 1 B. DEMO WALLS/FINISHES AROUND COLUMNS AS INDICATED. 1 8 I 2. DEMO EXISTING FIXTURES & EQUIPMENT AS INDICATED FROM PREVIOUS TENANT.PROTECT ADJACENT CONSTRUCTION TO REMAIN. Lu .J I 3. DEMO EXISTING DOOR, FRAME, & HARDWARE AS INDICATED. PROTECTADJACENT CONSTRUCTION TO REMAIN. M 8 14. DEMO EXISTING LIGHT FIXTURES AS INDICATED.SEE SHEET A4 FOR NEW LIGHTING LAYOUT. lil 3UzU 4A. DEMO EXISTING THERMOSTATS, SECURITY MIRRORS, MOTION SENSORS,&ALARM PADS AS INDICATED. u 1B 5. DEMO EXISTING HVAC DIFFUSERS & EXHAUST FANS AS INDICATED.SEE SHEET M1 FOR MECHANICAL LAYOUT. J - - - - - - - - - - - L - - - - - , - - - - - - - - - - - - - - - - - - - - - - - - - - {- - - - - - - - - - - - - 6. REMOVE EXISTING HVAC DIFFUSERS RETURN AIR GRILLES AS INDICATED, PROTECT FIXTURES FOR REINSTALLATION SEE _ SHEETS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - M - - - � - - - - - - - - - - - � � - - - - - - - - F-------- A4&M1 FOR MECHANICAL LAYOUT. 11 I M 7. DEMO EXISTING GYPSUM BD, CEILINGS AS INDICATED. SEE SHEET A4 FOR REFLECTIVE CEILING PLAN. CN I I 1 8. DEMO EXISTING FLOOR FINISHES TO CONCRETE SLAB. PREPARE FLOOR TO RECEIVE NEW FINISHES.SEE SHEET A3 FOR FLOOR FINISH PLAN. i I 1 9. DEMO EXISTING ELECTRICAL OUTLETS, CONDUITS, EQUIPMENT&CONNECTIONS AS INDICATED.SEE E1 FOR ELECTRICAL LAYOUT. Q Q M 8 9A. DEMO EXISTING ELECTRICAL PANEL AS INDICATED. REMOVE ALL CONDUITS AND WIRING.TRANSFER POWER TO OTHER REMAINING PANELS. 3 8 ; 10. DEMO EXISTING PLUMBING FIXTURES AS INDICATED. PROTECT ADJACENT CONSTRUCTION TO REMAIN.CAP OFF ALL PLUMBING CONNECTIONS / I REMOVE MIRROR INISH AS NEEDED. SEE P1 FOR NEW PLUMBING LAYOUT. OFF KNEEWALL& REPAIR 0 GYPSUM BD. 11. REMOVE EXISTING UTILITY SINK AS INDICATED.SALVAGE & PROTECT FOR REINSTALLATION.SEE SHEET P1 FOR NEW PLUMBING PLAN. } 8 II i/ V NOTES: 0 w OC 10 ----- G.C.TO PROVIDE REFUSE CONTAINERS FOR ALL TRASH REMOVAL AND REMOVE ALL DEMOLITION MATERIALS FROM THE SPACE PRIOR TO THE START a OF NEW CONSTRUCTION. 0 a- Q - - - Lu - - - - - - Lu L�1 I o 10 i I I 1 8 I II N O II I W Lu ~ Ln ' r _______� r_- _______r r _______r r__ _______� r____ M -- - ---- - ____-____- ' __--_-_-__- ' -- NOTE: DIMENSIONS ARE FROM FACE OF GYPSUM J PARTITION LEGEND BOARD TO FACE OF GYPSUM BOARD,U.N.O. 1x4 BASE TRIM P2 1x6 TRIM AROUND P1 3 5/8"20 GA MT. AROUND FULL BOTTOM FULL TOP PERIMETER Q KICKERS @ 48"O.C. PERIMETER OF OF COLUMN, PAINT P3 3 5/8"20 GA.MT. \\5e/Kl5CK /8"20 GA.MT. COLUMN, PAINT P3 FIRE CAULK AS REQ'D KICKERS @ 48"O.C. ERS @ 48"O.C. METAL STUDS TO PROVIDE HOLD C9 ROOF DECK.DO NOT DOWN CLIPS FOR CEILING.SEE A4 ATTACH TOP TRACK CEILING TILE& ALL TILES BUT ONE. CEILING TILE& CEILING TRACK 10 1/2" FOR TYPE TO ROOF DECK. � LEAVE ONE TILE I GRID ATTACHED TO CORNER TRIM ALL T4 MITER ALL SLATWALL GRID CEILING TILE& �� 3 5/8"20 GAGE METAL LOOSE FOR ACCESS. CEILING GRID 1 CORNERS 45° STUDS AT 16"O.C. 3 5/8"20 GAGE METAL GRID CORNERS, PAINT P3 @ STUDS AT 16"O.C. 3 5/8"20 GAGE METAL � [v, WITH ONE LAYER 5/8^ GYPSUM BOARD G61 GYPSUM BOARD ON WITH ONE LAYER 5/8" STUDS AT 16"O.C. FITTING ROOM/ GYPSUM BOARD ON WITH ONE LAYER 5/8" SALES AREA SLATWOOD SW1 cV WRAPPED COLUM ui CORRIDOR STOCK ROOM/ EACH SIDE. EACH SIDE. GYPSUM BOARD ON STUDS SALES AREA EACH SIDE. STOREFRONT BOARD WRAPPED PSUM o 3 5/8"-20 GA STEEL TLT ROOM CORRIDOR FITTING ROOM STOCK ROOM SALES AREA COLUMN STUDS GB1 STUDS @ 16"O.C.W/ TYPE"X"5/8"GYP. SECURE BOTTOM ( SECURE BOTTOM SECURE BOTTOM SECURE BOTTOM EXISTING 4°STEEL - Z BD.ON EACH SIDE TRACK TO CONCRETE TRACK TO CONCRETE TRACK TO CONCRETE TRACK TO CONCRETE 1 5/8"20 GA. MTL U U SLAB USING POWER SLAB USING POWER ( SLAB USING POWER SEE FINISH SLAB USING POWER TUBE COLUMN STUDS e SEE FINISH NOTES DRIVEN FASTENERS SEE FINISH NOTES DRIVEN FASTENERS SEE FINISH NOTES DRIVEN FASTENERS NOTES FOR DRIVEN FASTENERS COLUMN WITH FOR FLOOR FINISH MIN..145 AT 18"O.C. FOR FLOOR FINISH MIN..145 AT 18"O.C. FOR FLOOR FINISH MIN..145 AT 18"O.C. FLOOR FINISH MIN..145 AT 18"O.C. COLUMN WRAP d.00" �— z NOTE:ALL STEEL STUDS MUST BE SCREWED NOTE:ALL STEEL STUDS MUS BE SCREWED NOTE:ALL STEEL STUDS MUST BE SCREWED NOTE:ALL STEEL STUDS MUST BE SCREWED TOP AND BOTTOM ON BOTH SIDES TOP AND BOTTOM ON BOTH SIDES TOP AND BOTTOM ON BOTH SIDES TOP AND BOTTOM ON BOTH SIDES WALL PARTITION 1 HR RATED M P1 P2 TOILET ROOM P4 FITTING ROOM PARTITION P5 DISPLAY WALL PARTITION 2 COLUMN DETAIL J J ANSI/UL 263 - DESIGN NO. U419 A1.0 SCALE: 3/4" = 1'-0" P3 EXISTING TOILET ROOM P6 EXISTING DEMISING WALL (y PARTITION PARTITION [ 1x4 BASE TRIM P2 1x6 TRIM AROUND P1 AROUND FULL BOTTOM FULL TOP PERIMETER MENS WOMENS PERIMETER OF OF COLUMN,PAINT TLT ROOM TLT ROOM COLUMN, PAINT P3 P3 � 1 P1 CORNER TRIM ALL T4 $ 5/811 MITER ALL SLATWALL C) 103 102 P3 CORNERS @ 45° LU 1" 7" 711 CORNERS, PAINT 7,-5" 42 71-6" 48 3'-88" 48 44'-54" INSIDE TO INSIDE FURRING STRIP 0 ~ SLATWALL SW1 - � Lu 22-1 FACE OF STOREFRONT TO CEN ERLINE OF CASH&WRAPATTACHED TO FURRING WRAPPj STUDS ED COLUMN a H 1 11 -------------- -- ----------- ------ � ` STRIP WRAPPED � a � COLUMN STUDS r- 0 DEMISING WALL 1-5/8"20 GA. MTL STUDS W � o � LL1 � • j P6 REMOVE AND REPLACE SLAB A 4g" 2'_7" F- _ REQUIRED FOR CONDUIT �cilao EXISTING SERVICE DOOR SHALL INSTALLATION.(MATCH SURRO NDING) P3 rbc tO SEE SHEETS E-1 &E-4 FOR DET ILS. REMAIN. G.C.TO BOLT DOOR SW1 T EXISTING 4"STEEL TUBE COLUMN CLOSED, REMOVE HARDWARE,AND FURRING STRIPS F - ; - APPLY CLEAR SILICONE CAULK COLUMN AT WALL WITH P3 j P2 j o AROUND PERIMETER OF OPENING. ZO �IcV 1 CENTERPOINT <6> 5 o INSTALL NEW SECURITY BARS ON � U N P1 DOOR. REFER TO SHEET COLUMN WRAP Ln N 4'-0" 4'-0" A1.1-DOOR(1S)FOR W. w J SIM � 5 5 • • N o O O i iv DETAILS/SPECS. p M ------- --- - -- --- -------- ---- 0 91-0" r 3 COLUMN DETAIL w' u m 3'-0° 31.011 4-4- 6R co A1.0 SCALE: 3/4" - 1'-0" F- r'CbN 6 EXISTING STOREFRON (CLEAN L11 �, �j 11 I _ PLY 1. 3 10111 PRIOR TO TURNOVER) s Z Q In tih �' 2 DIMENSION NOTES: ~ ~ Q ouzo CORRIDOR 7R = HIBBETT SPORTS,INC.IS SOLELY RESPONSIBLE FOR THE DESIGN INTERPRETATION OF THE CONSTRUCTION ( 0 m uU (9J O _bN `�� DOCUMENTS. P1 105 1 11 N 47" 13-10-' '-6" 3'-0" 2 8 ANY DEVIATIONS FROM THESE DRAWINGS WITHOUT PRIOR HIBBETT,INC.APPROVAL WILL BE CORRECTED BY THE 10 G.C.TO BUILD OUT COLUMN 2'-6" LANDLORD AT LANDLORD'S COST. AROUND EXISTING BEAM.SEE EXISTING SERVICE DOOR SHALL DETAIL 2/A1.0&ELEVATION REMAIN.G.C.TO BOLT DOOR O O LL w } 0 w I— ' vF-. THE CONTRACTOR SHALL TAKE FIELD MEASUREMENTS AND VERIFY FIELD CONDITIONS AND SHALL CAREFULLY _z z_ O W z _j IY w z 9/A2.2 FOR FURTHER CLOSED, REMOVE HARDWARE,AND L z O Q W O a W PLY COMPARE SUCH_FIELD MEASUREMENTS,CONDITIONS,AND OTHER INFORMATION KNOWN TO THE CONTRACTOR WITH O z U- w LL O g INFORMATION. - APPLY CLEAR SILICONE CAULK U) c4 O w AROUND PERIMETER OF OPENING. THE CONTRACT DOCUMENTS BEFORE COMMENCING ACTIVITIES. ERRORS,INCONSISTENCIES OR OMISSIONS Iz w w I-- m O O m a P1 _ P5 = INSTALL NEW SECURITY BARS ON DISCOVERED SHALL-BE REPORTED TO HIBBETT SPORTS INC.AT ONCE. z z Q EXISTING SERVICE DOOR SHALL o� 7Id w p o w p W a REMAIN. G.C.TO BOLT DOOR 1 ir) N DOOR. REFER TO SHEET p J ? w w m z = w CLOSED REMOVE HARDWARE, , _ A1.1-DOOR(1 S)FOR THE CONTRACTOR SHALL NOT SCALE DRAWINGS. d Q cn Q iR 00 F- V Q = �O DETAILS/SPECS. >- w w -I O cmn ~ O INSTALL 3/4" PLYWOOD'FILLER iv Q w U = g z o INSIDE OPENING.APPLY CLEAR DIMENSIONS ARE NOT ADJUSTABLE UNLESS NOTED WITH PLUS/MINUS TOLERANCE. U Ft z �" U Q m m U W U SILICONE CAULK AROUND ,} w a m z O O co PERIMETER OF OPENING. EXISTING STOREFRON (CLEAN DIMENSIONS ARE INDICATED AS FOLLOWS UNLESS OTHERWISE NOTED: w >O U = Q ~O O a L 1 PRIOR TO TURNOVER) " O F- Cn O z p _ O W z 11 W 19'-44" 1 o- CONCRETE-FROM FACE OF CONCRETE TO FACE OF CONCRETE w w O O z O m z Z O Y z 4Lo Ll Ir r LLI Z } mow w PLY oLL MASONRY-FROM FACE,OF MASONRY TO FACE OF MASONRY OR FINISHED FACE OF INTERIOR WALL I_ w q w cn O O 0° Q z w ALONG ENTIRE 711 % ��N Z O W O p a. w I' z = m z � 5-o-8 INTERIOR WALLS-FRO ..FINISHED FACE OF GYP BD TO FINISHED FACE OF GYP BD UNLESS NOTED OTHERWISE Z w U) _j w q - O U m Q WALL,TYP.SEE p w zZ) aXX - � = — IL F- DETAIL 11/A2.2 G.C.TO BUILD OUT COLUMN L' p F= O O O W a p = O z AROUND EXISTING BEAM.SEE INTERIOR ELEVATION-F OM FINISHED FLOOR TO FINISHED CEILING OR FINISHED WALL TO FINISHED WALL O > z O 0 OF- p U) p w U U _, 00 DETAIL 2/A1.0&ELEVATION to = z F- w z v zQ W I- W Y w w `r 9/A2.2 FOR FURTHER z DOOR SHALL BE LOCATED WITH 18"MIN.CLEAR ON LATCH PULL SIDE AND 12"MIN.CLEAR ON LATCH PUSH SIDE,UNLESS O m - m(boo z D O C U O z D o U w STOCK AREA INFORMATION. I r OTHERWISE NOTED. I-- O _ a O z 101 1 V � o owwwWz W � � w EXISTING TOREFRONT(CLEAN rN ) z U) z O O w PRIOR TO TURNOVER) � � pv� uQj � � � � w0o0 EXISTING SERVICE DOOR SHALL CONTRACTOR NOTES: o () U O O z o m w O U REMAIN. G.C.TO BOLT DOOR SALES AREA LANDLORD G.C.TO INSURE THAT THERE IS GYP.BD.INSTALLED TO THE DECK ON HIBBETT S SIDE OF DEMISING WALLS. z z g _ - F- w O F O - .- t WO F- � pW Y � CLOSED, REMOVE HARDWARE, 100 ' O z z z z m m a Q w O INSTALL 3/4" PLYWOOD FILLER HIBBETT SPORTS,INC.IS SOLELY RESPONSIBLE FOR THE DESIGN INTERPRETATION OF THE CONSTRUCTION DOCUMENTS. w O O O O m z) O w w I— X w INSIDE OPENING.APPLY CLEAR 1 S o ANY DEVIATIONS FROM.THESE DRAWINGS WITHOUT PRIOR HIBBETT, INC.APPROVAL WILL BE CORRECTED BY THE V o v U U x cn > m w a ��m SILICONE CAULK AROUND I M LANDLORD AT LANDLORD'S COST. PERIMETER OF OPENING. REMOVE AND REPLACE SLAB AS REQUIRED FOR CONDUIT INSTALLATION.(MATCH FIRE EXTINGUISHER,ELECTRICAL PANELS,TELEPHONE EQUIPMENT BOARDS, ETC.,SHALL BE LOCATED IN ACCORDANCE SURROUNDING)SEE DETAIL 2/E-1 FOR WITH REQUIREMENTS SET BY THE GOVERNING AGENCIES. ANY LOCATIONS NOT SHOWN SHALL BE VERIFIED WITH © COPYRIGHT 2014 10- TRENCH CUT MEASUREMENTS. HIBBETT SPORTS, INC.'FRIOR TO ROUGH-OUT AND INSTALLATION, UNLESS OTHERWISE NOTED,THE ABOVE PANELS HIBBETT SPORTING GOODS, INC 211 AND/OR EQUIPMENT SHALL MAINTAIN INTEGRITY OF WALL FIRE RATING REQUIREMENTS. REVISIONS: P1 4_� THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE CAUSED BY HIS OR ANY 1 BD COMMENTS 04/02/15 -a4 o �''�,� SUBCONTRACTOR'S WORK. — T 211 IN THE EVENT THE CONTRACTOR ENCOUNTERS MATERIAL ON THE SITE REASONABLY BELIEVED TO BE ASBESTOS, PLY G.C.TO BUILD OUT COLUMN POLYCHLORINATED BIPHENYL(PCB),OR OTHER TOXIC MATERIAL WHICH HAS NOT BEEN RENDERED HARMLESS,THE AROUND EXISTING BEAM.SEE CONTRACTOR SHALL IMMEDIATELY STOP WORK IN THE AREA AFFECTED AND REPORT THE CONDITION IN WRITING TO DETAIL 2/A1.0&ELEVATION THE OWNER AND HIBBETT SPORTS,INC. 9/A2.2 FOR INFORMATION.RTHER P5 IMPORTANT NOTE: THE CONTRACTOR SHALL VERIFY THE CONSTRUCTION OF EXISTING FIRE ASSEMBLIES(PARTITIONS,FLOORS,ROOFS, FREDERICK J. GOGLIA DOORS,AND FRAMES)MEET THE RATINGS DESIGNATED ON THE DRAWINGS. IF DISCREPANCIES ARE DISCOVERED,THE ARCHITECT,NCARB,RDI G.C.TO PROVIDE IDENTIFICATION OF NEW AND CONTRACTOR SHALL MAKE ANY REPAIRS OR MODIFICATIONS NECESSARY TO ATTAIN THE PROPER RATINGS AND TO two CRAB ROAD,SUITE 300 ST.LOUIS,MO 63146 EXISTING FIRE RATED AND TENANT MEET LOCAL GOVERNING CODES. (314)4t5 240o FAX(314)m�2aoo """"'er`y''com 0 4R SEPARATION WALL. G.C.TO IDENTIFY PER FBC-B SECTION 703.6 THE INTEGRITY OF FIRE PROTECTIVE CONSTRUCTION SHALL BE MAINTAINED ON EXISTING WALLS,COLUMNS,BEAMS AND EXISTING TOREFRONT(CLEAN SECTION 703.6 MARKING AND IDENTIFICATION: FLOOR-CEILING ASSEMBLIES. PATCH ALL FIREPROOFING REQUIRED AND SEAL PENETRATIONS TO MAINTAIN RATINGS. - EXISTING SERVICE DOOR SHALL PRIOR TO URNOVER FIRE WALLS, FIRE BARRIERS,FIRE PARTITIONS REMAIN. G.C.TO BOLT DOOR ° tilm CLOSED REMOVE HARDWARE AND SMOKE BARRIERS,AND SMOKE PARTITIONS O THE CONTRACTOR SHALL VERIFY DIMENSIONS OF AS CONDITIONS,AND NOTIFY HIBBETT SPORTS,INC.OF ANY �r `r ANY OTHER WALL REQUIRED TO HAVE DISCREPANCIES. ALL INFORMATION SHOWN ON THE CONSTRUCTION DOCUMENTS IS BASED ON FIELD OBSERVATIONS G.C.TO BUILD OUT COLUMN APPLY CLEAR SILICONE CAULK PLY AROUND EXISTING BEAM.SEE 2'-6- PROTECTED OPENINGS OR PENETRATIONS AND/OR THE ORIGINAL CONSTRUCTION DOCUMENTS OF THE SPACE. ✓ ft AROUND PERIMETER OF OPENING. F a tiao P4 DETAIL 3/A1.0&ELEVATION ' ' CV SHALL BE EFFECTIVELY AND PERMANENTLY 7 0� INSTALL NEW SECURITY BARS ON °0 9 I 3R M 10/A2.2 FOR FURTHER � 48 _ DOOR. REFER TO SHEET IDENTIFIED WITH STENCILING. THE CONTRACTOR SHALL REMOVE ALL ABANDONED SYSTEMS AND CAP OR REMOVE EXISTING BRANCH LINES AS P6 P6 INFORMATION. P6 oo SUCH IDENTIFICATION SHALL: INDICATED IN THE MECHANICAL,PLUMBING,AND ELECTRICAL DRAWINGS. IF AN EXISTING SYSTEM IS TO REMAIN, , ; ' b A1.1-DOOR(1S)FOR 1. BE LOCATED IS ACCESSIBLE CONCEALED RELOCATE AND/OR REROUTE AS REQUIRED. DETAILS/SPECS. P1 0 �� �`' _I FLOOR. FLOOR-ATIC SPACES; N r 2. BE REPEATED AT INTERVALS NOT THE CONTRACTOR SHALL SURVEY AND DETERMINE THE REMOVAL OF EXISTING CONSTRUCTION,EITHER WHOLE OR IN :�� EXCEEDING 30 FEET(914 mm)MEASURED PART,AS REQUIRED FOR THE INSTALLATION OF NEW MECHANICAL,PLUMBING,AND ELECTRICAL WORK. 1gtia,�� 12'-115' 1_ " — 19'-74" — 281.1 " r�� IMPORTANT NOTE: HORIZONTALLY ALONG THE WALL OR 8 6'-0" PARTITION;AND THE CONTRACTOR SHALL NOTIFY HIBBETT SPORTS INC.OF ANY CONSTRUCTION DEFECTS FOUND IN UNCOVERING • CONTRACTOR TO PROVIDE 3/4" 150142 FITTING ROOM 3. INCLUDE LETTERING NOT LESS THAN 0.5 WORK IN THE EXISTING CONSTRUCTION. 4$" 4g" BENCH.SEE SHEET 88" 22 PRE-DRILLED PLYWOOD AND INCH(12.7 mm) IN HEIGHT, INCORPORATING DIMENSIONED FLOOR PLAN A-2.2 FOR DETAILS. HARDWARE TO COVER EXPOSED THE SUGGESTED WORDING:"FIRE AND/OR THE CONTRACTOR SHALL BE RESPONSIBLE FOR CORRECTING DEFECTIVE WORK IN EXISTING CONSTRUCTION WITHIN STOREFRONT GLASS FOR SMOKE BARRIER-PROTECT ALL TME LIMITS OF THE CONSTRUCTION AREA. THIS INCLUDES,BUT IS NOT LIMITED TO,UNEVEN SURFACES AND FINISHES AT LOCATION: # 1294 - 70'-3"LEASELINE TO LEASELINE HURRICANE PROTECTION. OPENINGS."OR OTHER WORDING, PLASTER OR GYPSUM BOARD. THE CONTRACTOR SHALL PATCH AND REPAIR SURFACES TO MATCH NEW ADJACENT DATE: FEBRUARY 2015 FITTING SURFACES. ROOM SHEET 1 FLOOR PLAN PARTITION WALLS NOTED TO BE DEMOLISHED SHALL BE REMOVED TO THE FULL HEIGHT OF THE PARTITION UNLESS " - QTHERWISE NOTED. A1.0 SCALE: 3/16 1 -0 104 REFER TO THE RESPONSIBILITY OF WORK ON SHEET T- DOOR, TRIM, AND FRAME NOTES DOORSCHEDULE 1 AND SHEET A-1 FOR DOOR SWING. U. ITEMS LISTED ON THIS PAGE ARE TO BE PROVIDED BY GC IN INSTALLATION OF W NO. ROOM DOOR SIZE DOOR MATERIAL FRAME NO. ROOM DOOR SIZE DOOR MATERIAL FRAME DOORS, FRAMES,AND HARDWARE AS NOTED, MATERIAL SALES AREA CORRIDOR MATERIAL r 11 THIS DOOR IS TO REMAIN 1S SALES 3'-0"x 7'-0" ALUMINUM/GLAZING ALUM. PUSH SIDE PULL SIDE SALES AREA/ T-0"x 6'-8" STEEL STEEL ALL SUBSTITUTIONS MUST BE PRESENTED IN WRITING TO THE HIBBETT UNLOCKED WHILE OCCUPIED SCORRIDOR CONSTRUCTION DEPARTMENT PRIOR TO PURCHASING. ANY NON-APPROVED DOOR CLOSER SUBSTITUTION WILL BE REPLACED BY THE CONTRACTOR AT CONTRACTORS COST. % 2"VINYL LETTERED ENTRY DOOR HARDWARE SALES TO CORRIDOR DOOR HARDWARE J Q ADDRESS ABOVE DESCRIPTION QTY. MODEL FIN. MANUF. WIRED GLASS / DESCRIPTION QTY. MODEL FIN. MANUF. DOORFRAMES: r , DOORv MORTISE CYLINDER 1 SUPPLIED BY HIBBETT EADLATCH \ _ / DEADLATCH 1 4510-3(5 LH Or 6 RH}201-628VERIFY DOOR HAND ALUM ADAMS RITE e � I,J..I SECURITY BARSco m ALL INTERIOR DOORS- DOORCLOSER 1 UN17500-(689 Alum or 690 Bronze) MATCH NORTON PADDLE � � DEADLATCH HANDLE 1 4560-(5 LH or 6 RH)01-130 VERIFY DOOR HAND ALUM ADAMS RITE J % DEADBOLT 1 MS1850S-310-(628 Alum or 313 Bronze) MATCH ADAMS RITE / `o \ DEADLATCH PADDLE 1 4590-(02 LH or 04 RH}00-628VERIFY DOOR HAND ALUM ADAMS RITE CECO SERIES"CU" F001 749X-CU(LH) F001 750X-CU(RH) O EXIT INDICATOR 1 4089-00-(130 Alum or 121 Bronze) MATCH ADAMS RITE / \ W CLOSER 1 1101 BF x 689 ALUM YALE / 1 z ' / \ DEADLATCH � v v DOOR THRESHOLD 1 1715-A-36(Verify Width) ALUM PEMKO / \ HANDLE BUTT HINGES 3 TA2714-4/z x4/z' ,-NRP -- McKINNEY DOOR SWEEP 1 18061-(C Alum or D Bronze)-NB-36(Verify Width) MATCH PEMKO DOOR SILENCER 2 608 GREY ROCKWOOD DOORS: o Q M ALUMINUM SECURITY " ALUM.FLAT BAR(PER DIM.) WINDOW 1 PROVIDED BY CONTRACTOR -- LOCAL `O BARS 3 2"WIDE X 36"LONG X 1/8"THICK MATCH LOCAL" CONTRACTOR'S OPTION TO INSTALL SOLID CORE WOOD DOORS OR METAL DOORS ASSEMBLY RATING: 1 HOUR REFER TO RESPONSIBILITY SCHEDULE ON SHEET T-1 UNLESS IN RATED WALL CONSTRUCTION. DOOR RATING:20 MIN GC TO PROVIDE AND INSTALL NEW DOOR&HARDWARE Z REFER TO RESPONSIBILITY SCHEDULE ON SHEET T-1 RATED DOOR,FRAME,&HARDWARE WITH UL RATING TAGS co GC TO PROVIDE AND INSTALL NEW HARDWARE SALES FLOOR PAINT DOOR&FRAME P3 ALL INTERIOR DOORS- M ENTRANCE INSTALL WEATHER STRIPPING AROUND PERIMETER OF DOOR OPENING METAL DOOR: `• , �+ *TO CECO SERIES"CU" CHMD x FL30 68 x CYL-CE-18ga �, N 1 S EXISTING DOOR NEW HARDWARE CORRIDOR M CN MECO SE IE WITH GLASS: CECO SERIES"CU" CHMD x LL30 68 x CYL-CE-18ga-WG NO. ROOM DOOR SIZE DOOR MATERIAL FRAME NO. ROOM DOOR SIZE DOOR MATERIAL FRAME MATERIAL MATERIAL WOOD DOOR: STOCK ROOM SIDE CORRIDOR SIDE O REAR EXIT 3'-0"x 7'-0" STEEL STEEL 3'-0" STOCK ROOM/ x fi'-8" STEEL STEEL CECO SERIES"CE" D001464XCE(LH)D001465XCE(RH)7R O INSIDE VIEW OF OUTSIDE VIEW OF CORRIDOR REAR EXIT DOOR HARDWARE DOOR CLOSER STOCK TO CORRIDOR DOOR HARDWARE NOTES: L] EXIT DOOR EXIT DOOR / DOOR W/ALARMLOCK DESCRIPTION QTY. MODEL I FIN. MANUF. / \ DESCRIPTION QTY. MODEL FIN. MANUF. FINISH NOTED ON SHEET A1.1 DOOR SCHEDULE&SHEET A2.1 INTERIOR ELEVATIONS LLJ HARDWARE / \ OCCURS ON BOTH SIDES OF DOOR AND FRAME UNLESS OTHERWISE NOTED. CYLINDER 1 SUPPLIED BY HIBBETT AUTO-LOCK LOCKSET 1 B-AU4605LN x 626 SATIN YALE O Z CLOSER ALARMLOCK 1 SUPPLIED BY HIBBETT CLOSER 1 1 101B x 689 ALUM YALE w / \ -VINYL STORE UN LESS-OBVIOUSLY SHOWN OTHERWISE, DOOR LOCATIONS NOT DIMENSIONED M LU / ALARMLOCK POWER 1 SUPPLIED BY HIBBETT \ / BUTT HINGES 3 TA2714-4 Wx4 W-NRP -- McKINNEY SHALL BE LOCATED 4" FROM FINISHED WALL TO FRAME. d PEEP HOLE SIGN F- / PULL PEEP HOLE DOOR CLOSER 1 7500-689 ALUM NORTON \ / DOOR SILENCER 2 1608 GREY ROCKWOOD CL \ / 0 ¢ E - / HANDLE \ BUTT HINGES 3 TA2714-4'/2'x4'/z'-NRP -- McKINNEY \ / REFER TO RESPONSIBILITY SCHEDULE ON SHEET T-1 ALL INTERIOR DOORS&FRAMES WITH FIRE RATING SHALL BE SOLID CORE,WITH < w o / o \ PULL PLATE 1 102x70C US28 ALUM ROCKWOOD LABEL ATTACHED TO DOOR EDGE.GC TO PROVIDE AND INSTALL NEW DOOR&HARDWARE W p i4- ~ LATCH LATCH PROTECTOR 1 320 US32D SS ROCKWOOD RATED DOOR,FRAME,&HARDWARE WITH UL RATING TAGS ZO AUTO LOCK TO BE ON CORRIDOR SIDE.KEYED WITH FITTING ROOM LOCK. EXIT OR EXTERIOR SURFACE DOORS WHERE REQUIRED TO BE PROVIDED BY \ / GUARD KICKDOWN 1 1 461 US26D SATIN ROCKWOOD ASSEMBLY RATING: 1 HOUR GC TO PROVIDE 4 KEYS TO LOCKSET GENERAL CONTRACTOR SHALL BE 1 3/4"THICK FLUSH METAL DOOR IN METAL FRAME, W \ ALARMLOCK / DOOR RATING:20 MIN J \ / DOOR VIEWER 1 622 DCRM CR ROCKWOOD THREE BUTT HINGES HAVING FIXED PINS, STRIKE PINS, STRIKE PLATE AND LOCKSET. \ / KICKDOWN DOOR THRESHOLD 1 1715-A-36(Verify Width) NEW DOORS ONLY ALUM PEMKO STOCKROOM i DOOR SWEEP 1 18061-C-NB-36(Verify Width) ALUM PEMKO S RAIN DRIP EDGE 1 346-C-40(Verify Width+4") NEW DOORS ONLY - PEMKO ASSEMBLY RATING: 1 HOUR REFER TO RESPONSIBILITY SCHEDULE ON SHEET T-1 TO CORRIDOR D M U DOOR RATING: 1 HOUR GC TO PROVIDE AND INSTALL NEW DOOR&HARDWARE W � ly J RATED DOOR, FRAME, &HARDWARE WITH UL RATING TAGS F— 5 INSTALL WEATHER STRIPPING AROUND PERIMETER OF DOOR OPENING 07 O U m , REAR EXITg = = � 2 coW � � ¢ In <C Z C:> N FRAME N p NO. ROOM DOOR SIZE DOOR MATERIAL MATERIAL i z_ q 3R FITTING ROOM 3'-0"x W-8" STEEL STEEL / FITTINGROOM DOOR HARDWARE / DESCRIPTION QTY. ,MODEL FIN. MANUF. a (� (9U_ w } Q WWI— °D a AUTO-LOCK LOCKSET 1 B-AU4605LN x 626 SATIN YALE / Z z z O W z w � w z Zo `�' SPRING BUTT HINGES 3 1502-4'/z"x4% - McKINNEY cn PUSH SIDE cn O O U- LL O uj 0 2 ASSEMBLY RATING: 1 HOUR DOOR SILENCER 2 608 GREY ROCKWOOD - w w w Z 00 Ow Z m a LU Q DOOR RATING:20 MIN REFER TO RESPONSIBILITY SCHEDULE ON SHEET T-1 GC TO PROVIDE�AND INSTALL NEW DOOR&HARDWARE PUSH SIDE p ? o w m z¢ wo coo Q Qu- S-' „ .< RATED DOOR, FRAME, &`HARDWARE WITH UL RATING TAGS w w w R O O cn z 6 2-0 INSTALL MIRROR ON OUTSIDE OF DOOR Q U> U _ J z o O Lu PAINT DOOR AND FRAME-P3 cn Lu<o WZO U) Hi 0wU GC TO PROVIDE 4 KEYS FOR LOCKSET IR SPACE - A ; > ly = Q I- O z a U UNDERCUT DOOR 3/4" zc� � � R FITTING ROOMCLEARJ OOR SPACE 3 ° ° � D - ZZ2 ZWz Woplz � o ? oz0w 3.. 3" 6- 6-. W w L- >. mQ - o SALES AREA STOCK ROOM NO. ROOM DOOR SIZE DOOR MATERIAL FRAME 111 8 7" 1" 8 7„ 0 w O m o- W �- Z = z MATERIAL w Q w Q LU O p PUSH SIDE PULL SIDE O Z m_ STOCK ROOM 12 48 12 48 W ) U) o W 0 o7 O U m 4R 3'-0"x 6'-8" STEEL STEEL j Q - ° 0 Z O o a. 0 3 = pw STOCK ROOM DOOR 4 DOOR CLOSER \\ SALES TO CORRIDOR DOOR HARDWARE SLATWALLOVER SLATWALL OVER ° Z uj Z 0 Z W - W ° Lu WIRED GLASS \ DESCRIPTION QTY. MODEL FIN. MANUF. 1x STRIPPING. 1x STRIPPING. 0 Z p _ Z U w DEADLATCH _ \ DEADLATCH 1 4510-3(5 LH or 6 RH)-201-628VERIFY DOOR HAND ALUM ADAMS RITE 1-1/2"LATTICE 1-1/2"LATTICE F- p = U Q O Z TRIM PAINTED s „ TRIM PAINTED / t , fn � � 0 � � fn0 ~ al - 3W °O PADDLE co DEADLATCH HANDLE 1 4560-(5 LH or 6 RH)01-130 VERIFY DOOR HAND ALUM ADAMS RITE (P3) /e GYPBD OVER (P3) %"GYPBD OVER U Z 0 Z cn Z p W z W v, �O CO DEADLATCH PADDLE 1 4590-(02 LH or 04 RH)-00-628VERIFY DOOR HAND ALUM ADAMS RITE 20 GA.STL STUDS 20 GA STL STUDS w Q Q p m U z LL \\ // CLOSER 1 1101 BF x 689 ALUM YALE @ 16"O C (TYP) o U I— z z U Z d m o O Z O @ 16"O.C.(TYP) Q O (n p >. U \ DEADLATCH HANDLE / , , _- 1"CORNER TRIM 1"CORNER TRIM CLEAR FLOOR SPACE I— z w U o_ O - p 00 BUTT HINGES 3 TA2714 4/2'x4/z"-NRP McKINNEY DOUBLE STUDS @ DOUBLE STUDS(� -7 W I- I- H W I H I- T4 PAINTED P3 T4 ( ) JAMB LOCATION. Z - - \ ( ) ( ) JAMB LOCATION. ( }PAINTED P3 Z O Y LL F- DOOR SILENCER 2 608 GREY ROCKWOOD z Z z z m - OW U O 20 GA.STL STUD 20 GA STL STUD / O m m O LL n. Q W - WINDOW 1 PROVIDED BY CONTRACTOR - LOCAL // V 3 o O O O = w luxiw a ASSEMBLY RATING: 1 HOUR REFER TO RESPONSIBILITY SCHEDULE ON SHEET T-1 N PAINT FRAME P3N PAINT FRAME P3 DOOR RATING:20 MIN GC TO PROVIDE AND INSTALL NEW DOOR&HARDWARE RATED DOOR,FRAME,&HARDWARE WITH UL RATING TAGS 8" STOCK ROOM PAINT DOOR&FRAME P3 HOLLOW O LOW MEHIBBETT HOLLOW METAL M / O COPYRIGHT 2014 4 R CASED OPENING I ETT SPORTING GOODS, INC NO STOP i PULL SIDE DOOR. RE:SCHEDULE DOOR. RE:SCHEDULE REVISIONS: NO. ROOM DOOR SIZE DOOR MATERIAL FRAME MATERIAL JAMB JAMB PUSH SIDE OTOILET ROOM 3'-0"x 6'-8" PAINT READY STEEL Z 12" SOLID CORE WOOD / 6"' 8" Z " TOILET ROOM DOOR HARDWARE 7 / 1 4- 1- 4- CLEAR FLOOR SPACE FREDERICK J. GOGLIA / DESCRIPTION QTY. MODEL FIN. MANUF. 2 8 2 8 V* ARCHITECT,NCARI RDI / PRIVACY LOCKSET 1 AU4602LN x 626 SATIN YALE io =p SPRING BUTT HINGES 3 1502-4%2"x4%z" McKINNEY 19M CRAIG ROAD,SUITE 900 ST.LOUIS,MO 63146 \ DOOR SILENCER 2 608 GREY ROCKWOOD ?, SLATWALL OVER SLATWALL OVER `s PK(314)415-2400 FAX(314)415-2300 www.arcv.com \ - \ REFER TO RESPONSIBILITY SCHEDULE ON SHEET T-1 1x STRIPPING. 1x STRIPPING. 1-1/2"LATTICE 1-1/2"LATTICE — \ GC TO PROVIDE AND INSTALL NEW DOOR&HARDWARE TRIM PAINTED TRIM PAINTED aaa UNDERCUT DOOR 1"FOR RETURN AIR SPACE (P3) %"GYPBD OVER (P3) %"GYPBD OVER 20 GA.STL STUDS 20 GA STL STUDS TYPICAL DOOR @ 16O.C.(TYP) @ 16"O.C.(TYP) 1"CORNER TRIM - 1"CORNER TRIM TOILET ROOM (T4)PAINTED(P3) STUD CHANNEL& STUD CHANNEL& MTL STUD HEADER (T4)PAINTED(P3) 5 HEADERD 4 ADA FLOOR CLEARANCE y +z A1.1 SCALE: 1/2" = 1'-0" tit- r �" PAINT FRAME P3 _ PAINT FRAME P3 ' 3' N CV .0 INSTALL CLOSER ARM `�t4•{/_ f � `S`" PARALLEL TO STOREFRONT HOLLOW METAL STOREFRONT HOLLOW METAL ADJ.FRAME CASED OPENING, FRAME e sue NO STOP STOREFRONT DOOR. RE:SCHEDULE STOCK ROOM DOOR DOOR 150142 DOOR SCHEDULE&DETAILS LOCATION: # 1294 HEAD HEAD - - - - - - - - - - - - - - - - - - - - - - - DATE: FEBRUARY 2015 1 JAMB & HEAD DETAIL 2 JAMB & HEAD DETAIL 3 DOOR CLOSER ARM DETAIL SHEET A1.1 SCALE: 3" = 1'-0" FITTING ROOM DOOR A1.1 SCALE: 3" = 1'-0" @ STOCK ROOM DOOR A1.1 SCALE: NTS A� i a i 4'-0" 4'-0" 4'4" Q U. w .. UPRIGHT(S) o � J UPRIGHTSZ 80 o OPEN UPRIGHT _ _ UPRIGHTS) ASSEMBLY o o b o INSTALL SHELF in 80 CO e a INSTALL SHELVES PEN UPRIGHT CONTRACTOR WITH TAB:�, PEN UPRIGHT SUPPLIED#8 X 1 PER DETAILS ASSEMBLY ASSEMBLY 3/4"HHSMS TOP `- 6,7,8,10/A2.0 � � &BOTTOM � ui BRACING BRACING BRACING 0 0 ' ---------- 04 CV ..1 .0 ZA --- Q 4 UPRIGHT CONNECTION DETAIL 5 TYPICAL SHELVING ELEVATION TABS FACE UP FOR J PROPER WARNING:NGELATFORMUST NOT BEUSED ASALADDER,WALKWAY, NOTE: IF FREE STANDING INSTALL A2.0 SCALE: N.T.S. A2.0 SCALE: N.T.S. INSTALLATION OF M OR STANDING PLATFORM 1. BOTTOM SHELF MUST START AT FIRST SLAT FROM FLOOR SLATWALL ON BOTH SIDES WOOD SHELVES. 2. 10 EMPTY SLOTS IN BETWEEN SHELVES STOCK J 2 3 ROOM `v STOCKROOM SHELVING DETAIL SLATWALL ON SHELVING DETAIL SHELF __ ___� N A2.0 SCALE: N.T.S. A2.0 SCALE: N.T.S. 10 SHELF SLOT DETAIL SHELF WOMEN'S SHELF A2.O SCALE: N.T.S. �. UPRIGHT TOILET ROOM C� -3 1 -0' 102 UPRIGHT LLI BOTTOM SHELF 1. UPRIGHT o w 2.20 GA X 1 X 1 BENT PLATE I r79" o GOES BOTTOM 2 3.#8 SCREW TO UPRIGHT a MENS O I 4 % 4 3 74 """74 4 4 3 4 4 SLOT �1 4. HILTI X-U SHOT PIN(3/4" CL SHELF � �► EMBEDMENT) <, d TOILET ROO 7 0 LLJ �,1 y2 UPRIGHT 5. SLAB ON GRADE W' O <� WHEN INSTALLING 103 A2.2 4 STOCK ROOM SHELVES, (1) o H Z 4 10 SPACES MUST BE U j i A2 2 A2'2 6 UPRIGHT SHELVING DETAIL BETWEEN EACH SHELF 00 .� AS SHOWN HERE. �� A2.0 SCALE: N.T.S. (3 (2) h • 4'-0" 4'-0" 13'-112'T FACE OF SLATWALL iii Q. 6 A2.1 (4 (5) ,� Z 2'-0" COR R 4 X BRACE A2.2 UPRIGHT W M U 20 GA X 1 X1 BEN H j J rn 105 CASH W P COUNTER SCREW(#8X3/4"HHSMS) 11 SHELVING FLOOR ANCHOR DETAIL PLATE ANCHOR Q m RE: DETAI 9/A-2.0 U m A2.0 SCALE: N.T.S. w N ---- 3 4 1 X 4 o M (1)XB-48cn 4 ❑ LIJ Z Q In o N SEE A2.2 STOCK swi N m U SW1 ch SW1 ROOM ' O^ Ce o 4NtIt x x x x A2.2 "' n8' ------ NOTE: RACK DETAILS SHOWN FOR INFORMATION & A2.0 10 X x x xSTART AT SLOT REFERENCE ONLY. SYSTEM SHALL BE INSTALLED BY 8 A2.0 INSTALL UPRIGHT CROSS CLOSEST TO THE FL OR. FLOOR QUALIFIED VENDOR WHO IS RESPONSIBLE FOR DESIGN BRACING AS INDICATED PER FABRICATION & INSTALLATION C7 C9u- w >- ❑ wXf- A2.0 ,z MANUFACTURER'S UPRIGHT HEIGHT 96 OVERHEAD. BRACE o z O ¢ W O a w `r ` RECOMMENDATIONS "b°° 7 8 SHELF INS ELATION DETAIL " z o z w LL o 6 A2.1 A2.0 SCALE: N.T.S. #12 X 3/4 TEK SCREW E0 w w ~ m c7 w a ~ x x x x x A2.0 SCALE: N. S. v, O w 4 A2.2 UNITS. OVERHEAD ATTACH WITH (2) #12 xE3/4" SELF TOP OF HE o p _j z Fw w w m z w i d d DRILLING, SCREW THROUGH THE STEEL OF THE o O ❑ ¢ U- Q X ❑ L4 wwFrO tnF- z X X i ° " X X BRACE INTO THE TOP SHELF EACH SIDE. d d � �. _ ,� O - O ALL STOCKROOM SHELVING N �� - INSTALL OVERHEAD BRACING ON CP d 0 jj Z F- U Q m v I- AGAINST WALL TO BE SECURED 1 s ch 4'-2s" - PIONITEHARDROCKMAPLE EVERY OTHER UPRIGHT O w a m z O o X Z) TO 1x10 STRIPPING. LAMINATE#HP290 PIONITE HARDROCK MAPLE 8 „ W > w �. Z O Z a U- RE: FURRING STRIP ELEVATIONS x X x X x ¢ 0 4 A2.1 3A&3B .018'PVC TO MATCH LAMINATE TEK SCREW SHELF TO 4 > O U _ ¢ O - In ❑ M MIN. O E- tn0 Z ❑ - C9wZ 4s. W290HARDROCKMAPLE UPRIGHT - INSIDE OF SHELF '9-{'j III ❑ H z z I- x x g 2 EDGECO#7029 (ONLY SHELVES WITH MSM O ❑ 0 w o Z o N ❑ ELEVATIONS cINTERIOR � CORNERSOVERHEADEACHCING) 4 w ¢ w x Z o �❑- 9 Lu < w X -3" x x 3-p" x x X-13" x O A2.2 �o w 0 ❑ o- ptp � zUMLU � D' Z Z) w LL >C U LN ` 00 jR LL 00 > ZcW901- 00 W01 z SALES AREA = z 1- 2Z0 < Wa w1= Y � X X X X 100 - o � _ _ = U UUIYw `- 3'O.C.SLATWALL MELAMINE c7 ❑ O U ❑ Q o Z d FINISH. W290 HARDROCK r cn ❑ In In ❑ z Lou- 1- -5 w x x USE HIBBETT PROVIDED 3'-0" MAPLE HARDROCK MAPLE z to z In Z w 0 w a) w °) PIONITE SG213 OPTI GRAY w w T Q Q o m U U z o `� OR 4'-0"SHELVES TO GAUGE MELAMINE g_ U ❑ too O LAMINATE TOE KICK � 0 � U x x x x x DISTANCE OF STANDARDS i KNOCKOUT 8'x8"ACCESS PANEL CKOUT ❑ f%l V O O _ Z a m ❑ U Zo U cn - w LL FRONT VIEW PIONITE SG213 OPTI-GRAY RE R VIEW W 1- � � ~ � � � W � o F- � ZZZM WE STOCK AREA i LAMINATE TOE KICK. OZ o ❑ ❑ Lu m O w 0 0 0 00 _ : w IL w vqT ver �t AGANSOTWALLLOOBELVING � ❑ UUU = cn � > � cnxw 101 x x X X X SECURED TO 1x10 STRIPPING. 9 CASH WRAP DETAIL x N A2.0 SCALE: 3/8" = 1'-0" © COPYRIGHT 2014 x X X X X ❑ HIBBETT SPORTING GOODS, INC v 4 xA2.2 REVISIONS: N 1 BD COMMENTS 04/02/15 sw1 X X X X q2,2 M NOTES: 12 SHELVING OVERHEAD BRACING DETAIL SW1 SALES AREA A2.0 SCALE: N.T.S. SW1 _ 1.USE HIBBETT PROVIDED 3'-0"OR 4'-0"SHELVES TO GAUGE DISTANCE OF STANDARDS IN SALES REDERICK J. GO AREA. �� GLI A C? �- STOCKROOM 6 A2.1 NOTE: WHEN WALL IS CONCRETE BLOCK, ATTACH CHFECT,NCARB,RDI D ~ 1.S�TOCKAREA MUST BE SECUREDL SINGLE ROW SHELVES NST WALLS IN AT TOP TO 1x10 FURRING TO CONCRETE W/ HILTI HIT HY20 1/2" CRAIG ROAD,SUS 300 ST.LOUIS,MO 63146 DIA. X 6 EMBEDMENT AT 16 O.C. STAGGERED. (314)4152400 FAX(aw)4ls23°° '"'""ercv�m - BLOCKING FIXED ON WALL " �N 2.BOTTOM SHELF MUST START AT FIRST SLOT FROM FLOOR. 5 MR2 1B 4 FIXED SHELVING UNITS A2.2 4 ih 3.WARNING:SHELVES MUST NOT BE USED AS A ° w I �•2 A2.2 LADDER,WALKWAY,OR STANDING PLATFORM. 6 0 1A A2.2 1C 10 o G.C. TO MOUNT 1" X 10" FIRE TREATED WOOD . . Fw1 MR ° q2.2 ® FURRING STRIP TO EVERY WALL STUD W/ (3) #12 ' 1D rbo0 p STEEL 2 1/2" LONG TEK COUNTERSINK HEAD p;q ° o SCREW FLUSH WITH BUT NOT LOWER THAN ° o SURFACE OF FURRING. INSTALL WASHERS WHERE 4 4 4 4 4 3 4 4 3 4 4 3 _ _ ° ° FURRING IS SOFT. <=• 1„ - - ' NOTE: DRYWALL SCREW ARE NOT ACCEPTABLE ' r 8-0 3-18 2'-5a" o p BENCH �x - FITTING 2'-18" SEE DTL.3 ROOM 3" 3" 1'- " o o ATTACH SHELVING UPRIGHT POST LOCATED " " 3�1�3y0�w SHEET A-2.2 p o AGAINST THE WALL TO 1 X 10 F.R.T. FURRING W/ (2) TAMPER PROOF TORX SCREWS PER 0 o UPRIGHT POST. THROUGH THE STEEL OF THE 150142 p UPRIGHTS. FIXTURE PLAN ° * USE Y4' DRILL. PRE-DRILL UPRIGHTS BEFORE S. 1 A2FIXTURE PLAN ° USING RWLOCATION: # 1294.0 SCALE: 3/16" = 1'-0" X 2 HEX HEADS o USED IN PLACE OF TAMPER-0" PROOF SCREW ORX BE DATE: FEBRUARY 2015 SHEET 13 SHELVING WALL ANCHOR DETAIL A2.0 SCALE: N.T.S. A�2 0 0 0 FINISH LEGEND SEE SHEET T-1 & FINISH SPECIFICATIONS INTERIOR FINISH SPECIFICATIONS J 0 0 PAINTING&WALL COVERING F. NOTED AS(P2) Q NO. MATERIAL MANUFACTURER SPECIFICATIONS ALMOND FINISH COLOR. PRODUCT#SW6114 UPRIGHT SLOTS A PROVIDE ALL LABOR,MATERIALS,EQUIPMENT,AND OPERATIONS DESCRIPTION:"BAGEL"SIZE:1 GALLON w ., 0 O TO LINE UP GB1 FINISHED GYP BD. "LOCAL" 8'-0"x 4'-0"x 5/8" (1/2"AS SPECIFIED) NECESSARY TO COMPLETE THE WORK OF THIS SECTION IN (DIRECT TO METAL PAINT)STANDARDS 0 O ACCORDANCE WITH THE CONTRACT DOCUMENTS.THIS WORK (LATEX FOR FITTING ROOM SATIN FINISH) � J CONTINUOUS 1x6 0 MUST BE LEVE P2 PAINT SHERWIN WILLIAMS "BAGEL"#SW6114 INCLUDES,BUT IS NOT LIMITED TO,THE FOLLOWING: / 1 STANDARDS,SEE MDF TRIM BOARD, 0 P3 PAINT SHERWIN WILLIAMS "STRUCTURAL GRAY"#SW4031 A.I. PRIME ANY UNPRIMED SURFACES TO BE PAINTED UNDER G. NOTED AS(P3) rn v DETAIL 5/A2.1 PAINTED T1P3 0 THIS SECTION. GRAY FINISH COLOR. PRODUCT#SW4031 0 0 P4 PAINT- RESTROOM(S) " A.2. PAINT GYPSUM BOARD THAT WILL BE EXPOSED TO VIEW, DESCRIPTION:"STRUCTURAL GRAY' SIZE:1 GALLON - _....._..---....._..-----.._...-----.............____._...._._._._._..-------......_...._......_....._.........--___._._.._._._......__...______....._............_..._..... .:-:::_::,:_._::_:___._ __-:.._._..,....._._:_:___:_.-_:_:__:_::__--___:_:_.:::_:_:__,_._:,__:_:.:::___:_:_:_:_:,_:::__:_._,,.__:,.-__ __:_:-:_._:_:_:_: ETHEREAL WHITE" 1 2 _....,. ___ _:_ _-_ O SHERWIN WILLIAMS H #SW6 8 - - --= �- - - - - EXCEPT WHERE OTHER FINISHES ARE REQUIRED. 0 W I 0 0 SW1 SLATWALL MODULAR WOOD HARD ROCK MAPLE MELAMINE A.3. PAINT ANY WOOD TRIM THAT WILL BE EXPOSED TO VIEW, H. NOTED AS(P1) A.4. FINISH PAINTING OF SHOP PRIMED FERROUS METALS,SUCH MULTISPEC FINISH COLOR. m SW2 SLATWALL MODULAR WOOD HARD ROCK MAPLE MELAMINE (SHOEWALL) AS HOLLOW METAL DOORS AND FRAMES,DOOR BUTTS AND COLOR: "ROCKY ROAD"MS86-3067 W SW1 __ SW1 T1 MDF TRIM "LOCAL" 1 x 6 PRIMED MDF (PAINT GRAY P3) MISCELLANEOUS FERROUS METALS. SIZE: 1 GALLON z A.5. PROVIDE INCIDENTAL PAINTING AND TOUCHING UP AS VERIFY WITH HIBBETT SPORTS PRIOR TO PURCHASE. U U T2 MDF TRIM "LOCAL" 1 x 4 PRIMED MDF (PAINT GRAY P3) REQUIRED TO PRODUCE PROPER FINISH FOR ALL PAINTED MUST BE LEVEL SURFACES,INCLUDING FACTOR PAINTED ITEMS. I. TOUCH UP PAINT REQUIRED TO BE LEFT ON SITE: T3 MDF CORNER TRIM "LOCAL" 1 x 2 + 1 x 2 PRIMED MDF CORNER TRIM (PAINT GRAY P3) MANUFACTURERSE NTH ONE(1)GALLON OF EACH COLOR USED. Q O Q T4 MDF CORNER TRIM LOCAL 1 x 1 ONE PIECE MDF CORNER TRIM (PAINT GRAY P3) B INSTRUCTIONS,. APPLY REGARDINGNT IN APPLICATION PPL CAT ON OF MATERIAL AND INTERIOR AND EXTERIOR TRIM MILLING SW1 SW1 SW1 SW1 SW1 SW1 SW1 SW1 SW1 SW1 SW1 SW1 PREPARATION OF SURFACES. coco T5 MDF CORNER TRIM "LOCAL" 1 x 3 + 1 x 2 PRIMED MDF CORNER TRIM (PAINT GRAY P3) A. INDUSTRIAL GRADE MEDIUM DENSITY FIBERBOARD — — PLY PLYWD SHEATHING "LOCAL" 4'-0"x 8'-0"x 1/2" FRT PLYWOOD C. PUT SUBSTRATE SURFACES IN PROPER CONDITION BY CLEANING, (MDF)WITH FORMALDEHYDE FREE BINDER.EXCEED J ^ , 4'-0" 4'-0"= 3'-0" Ll2" 4'-0" 4'-0" 4'-0"= 4'-0" 12" 3'-0" 4'-0" 4'-0" 3'-1" e. SANDING,AND PUTTYING.PAINTING CONTRACTOR SHALL NOTIFY ANSI A208.2-1994.PRODUCT CLASS MD. N 10 THE GENERAL CONTRACTOR OF UNSUITABLE SUBSTRATE,OR ASSUME THE RESPONSIBILITY OF CORRECTING ANY B. INSTALL INTERIOR TRIM IN ACCORDANCE WITH -"` UNSATISFACTORY FINISH RESULTING.DO NOT LEAVE RUNS, AW.I.STANDARDS. DRIPS,ETC.SAND BETWEEN ALL COATS OF PAINT ON m co 1x4 MDF TRIM BOARD, 1x4 MDF TRIM BOARD, 1x4 MDF TRIM BOARD, 1x4 MDF TRIM BOARD, WOODWORK. PAINTED T2 P3 PAINTED T2 P3 PAINTED T2 P3 PAINTED T2 P3 441-4- 1 A" D. PAINTS:COMMERCIAL GRADE,AS INDICATED ON THE ROOM '. �'F�'F-�'F FINISH SCHEDULE&FINISH SPECS ON THIS SHEET. _0 1 INTERIOR ELEVATION E. AFTER COMPLETION OF WORK,CONTRACTOR AND TENANT SHALL LLI A2.1 SCALE: 1/4" = 1'-O" @ RIGHT DEMISING WALL MAKE A DETAILED INSPECTION OF THE WORK.REFINISH ALL Q z DISFIGURED PORTIONS TO PRODUCE AN ACCEPTABLE FINISH. CL W REMOVE ALL SPATTERING OF PAINT FROM ADJOINING WORK. Q.. ZI Ia Q a FD I00 w CONTINUOUS 1x6 MDF CORNER CONTINUOUS 1x6 NOTE: W MDF TRIM BOARD, STANDARDS,SEE 01 10 TRIM, PAINTED MDF TRIM BOARD, 1- Z PAINTED T1 P3 DETAIL 5/A2.1 aI I> T4 P3 PAINTED T1 P3 SLATS ARE 3"O.C.AND SHOULD BE LEVEL WHERE BOARDS MEET. W O _ J _ ..........._�.._... _....... ... r__,...:_,_ _.._...... .. :_v: _ .v.� .. ............:.:-......;..w:.wv....�............. ...:..:...._-.......... - :..-,... ....:.:.....,....:mnw...:.:..wnw:..w.............w.�.:w ..w.v:..:..w:.:..�.,.......------. -......,,.....,..........u.....:.......,w.:.......:... -w:w.......:�-- -.,.-,....W.,.,.�..........,.,.....>.,.:: 1 11 1 11 __:...----- ............_.._......__.. _._-:..----..,_...._....:.....:..._........._...._.:._._..---. . : -.: ...:_-.: .....------._ -_..:-_ -----_......... _-= -_ = - -= -------- -- ------ _ -- -----------_ - - NCE OF STANDARD - - --------- --- - - - --- -- - -= ---- - USE HIBBETT PROVIDED 3 0 OR 4 0 SHELVES TO GAUGE DISTANCE S DO NOT USE MEASURING TAPE TO GAUGE DISTANCE BETWEEN STANDARDS. _ SW1 ri , GENERAL NOTE. SHELVES MUST FIT&BE LEVEL FROM TOP TO BOTTOM OF STANDARD. N O HIBBETT G.C. IS RESPONSIBLE FOR OBTAINING PAINT PRIOR TO UPRIGHT AND FURRING INSTALLATION SEE SHEET A2.0.ANY DISCREPANCIES CONTACT W M U _ SAMPLE BOARD FROM HIBBETTS CONST. DEPARTMENT. HIBBETTS CONSTRUCTION DEPARTMENT FAILURE TO DO SO WILL RESULT IN CHANGE ORDER NOT BEING ui 5 --j L c. FAILURE TO DO SO MAY RESULT IN REPAINTING THAT AUTHORIZED. O Q N SW1 SW1 SW1 SW1 SW1 SW1 SW1 SW1 SW1co W U : mo� WILL BE AT THE EXPENSE OF HIBBETT G.C. CONTACT MODULAR WOOD (JERRY DENENBERG)AT 561-336-3777 FOR SLATWALL ORDERING Q = INFORMATION. SEE=A-3 FOR ADDITIONAL INFORMATION. _ 5/8",, �" 311 W �-� Z b 2'-5 7/8 —3'-0" 4'-0"= 4'-0" 3'-0" 12" 4'-0" 4'-0"= 3'-0" X11 5/8 i 41-0" 4'-0" 4'-0" 4'-0"= 3'-1 1/8" DOOR STOP TO CONTACT IMPRESSIONS(PAUL HILL)AT 866-975-0444 FOR STANDARDS ORDERING INFORMATION.SEE A-3 O o MATCH HEIGHT OF FOR ADDITIONAL INFORMATION. mr Q p ci Z .� -_-- .-_-:----.----._. DOOR HANDLE C'3 N m v010 @l 1x4 MDF TRIM BOARD, 1x4 MDF TRIM BOARD, 1x4 MDF TRIM BOARD, 1x4 MDF TRIM BOARD, PAINTED T2 P3 PAINTED T2 P3 PAINTED T2 P3 PAINTED T2 P3 49'-0 1/2" � C9 C9u. w >- ❑ wW ►- z zzO � zQ � 0paw w 2 IN ELEVATION co x x m o m a I.- SCALE:A2.1 1/4 - l'-O" @LEFT DEMISING WALL ZI IZ ZI �� �_ wZw ❑ 0w ❑ Lu } Z ❑ J - r W W m Z W al MDF CORNER CONTINUOUS 1x6 la al MDF CORNER CONTINUOUS 1x6 la w Q w w O 0 cn I=- z o>� TRIM, PAINTED MDF TRIM BOARD, to MDF CORNER of to MDF CORNER -� } - -' cn - UOUS 1x6 STOREFRONT SOFFIT > >_ TRIM, PAINTED MDF TRIM BOARD, > o< W U O= o W z ❑ O CONTINUOUS PAINT z ° T3 P3 PAINTED T1 P3 la TRIM, PAINTED �� T4 P3 H Q - PAINTED T1 P3 la TRIM, PAINTED U � Q U m m U w U BULKHEAD ABOVE GLASS o -= -=- = _:__- - - _ == -' T3 P3 _ =-- _ - - --- -_ -- > W ❑ m p Z w T4 P3 MDF TRIM BOARD, NEW SOFFIT 9'-8" °I NEW SOFFIT 9'-8" NEW SOFFIT 9'-8" PAINT STOREFRONT SOFFIT CONTINUOUS 1x6 w z a u. :: PAINTED T1 P3 BETWEEN TRIM P2 @ PAINT STOREFRONT SOFFIT c @ @ > A.F.F. PAINT WHITE o� A.F.F. PAINT WHITE A.F.F. PAINT WHITE BULKHEAD ABOVE GLASS MDF TRIM BOARD o � U) U ¢ z ❑ - O w z BULKHEAD ABOVE GLASS > _ =_ == TO MATCH CEILING O a TO MATCH CEILING TO MATCH CEILING BETWEEN TRIM P2 PAINTED T1 P3 z w ❑ O w � o m p z 0 BETWEEN TRIM P2 — _ w_ u...,..0 z L------------- u cn O SW1 SW1 O LL p mQwt- w c7 = wz GYPSUM BOARD Z � -� w ❑ m O z U m U) — w WALL, PAINTED o � p � Z O w a Z) 0 ov; > zcn0 (9 0 c, zoZ o P2 ._ P2 P2 = Z F- wzU ¢ W ~ wOY � o SW1 SW1 SW1 k (n � � owwwoz w � 3W 11 1 11 1 11 1 " " 11 S- LL 2 � O w 0 `/ � >- V, U O 3 4-0 4-0 3-0 Ll2 3 ❑ U F- z z lJ m ❑ z U r / I rr rr ri rr rr rr r rr rr z w F- E E I_ Y _ `'' I— zm " oo �nz � ❑ �- oo F7 P2 P2 I P2 LP2 P2 w O a, _.. ....... � z 1- ❑ ❑ w2XLL O � U0 = _ - zzzmmO � a � W � - = - -- _- V � o OOO = v=i0 > � F<— 1x4 MDF TRIM BOARD, 1x4 MDF TRIM BOARD, F<- STOREFRONT ONT 1x4 MDF TRIM BOARD, PAINTED T2 P3 PAINTED T2 P3 1x4 MDF TRIM BOARD, 1x4 MDF TRIM BOARD, ENTRY DOOR PAINTED T2 P3 PAINTED T2 P3 PAINTED T2 P3 72'-7 5/8" 12'-6" 12'-6" © COPYRIGHT 2014 r3BN� INTERIOR ELEVATION 6 INTERIOR ELEVATION HIBBETT SPORTING GOODS, INC r3AN� INTERIOR ELEVATION �F A2.1 SCALE: 1/4" = 1'-0" DISPLAY WALL TYP A2.1 SCALE: 1/4" = 1'-0" REVISIONS: A2.1 SCALE: 1/4" = 1'-0" @ STOREFRONT °� { ) @BEHIND DISPLAY WALL {TYP) r3 72'-7 5/8"SHOE DISPLAY AREA NEW SOFFIT @ 9'-8" CONTINUOUS 1x6 A.F.F. PAINT WHITE MDF TRIM BOARD, FREDERICK J. GOGLIA CONTINUOUS 1x6 NEW SOFFIT @ 9'-8" CONTINUOUS 1x6 NEW SOFFIT @!)-8" TO MATCH CEILING ARCHITECT,NCARB,RDI PAINTED T1 P3 :.: :, :., F P D BOARD A.F.F. PAINT WHITE A.F. PAINT WHITE MDF TRIM �� � � �� ���' � �`� MDF TRIM BOARD, ,..:-::..;, : ::: t 1950 CRAIG Bono,sum 300 sr.Loins,Mo 63146 PAINTED T1 P3 TO MATCH CEILING PAINTED T1 P3 TO MATCH CEILING _:_...:. _.__.___ _.._.._ - = 5/8"GYP BD PR(314)415-2400 FAX(314) 15-2300 wwwarcvcan _ ON M _._._._._ _ __ ---- - ---- - _ - _ _ _ T 4 L STUD -- - -- ___ -._.__ - _ = _ = ------- --- -- =- _ -- _:: _ 1X10 WD ' FURRING STRIP P3 �ME N. FRAME& F - FRAME& t+r Ai C CD DOOR DOOR c� - DOOR _ sw2 �� sw2 sw2 sw� sw2 sw2 sw2���, sw2 SW2 <�TsM N MIRROR - _ a e _ = Mia a SLATWALL �\ 8'-011 SHELF 3 4 — O STANDARD _ - --._ -- - - = - -._._. .. . :._-..__... ..:.......... _ :.....__... - -:__.._:...._.....__......._.__. ..-. ...- _..._..._......_......-...__...... .._..-._ _......_....._..__.:. - SLATS '� FITTING ROOM STOCK ROOM CORRIDOR <� 42 DOOR DOOR DOOR INTERIOR ELEVATIONS 1x4 MDF TRIM BOARD, 1x4 MDF TRIM BOARD, 0 1x4 MDF-I-RIM BOARD, SLATWALL LOCATION: # 1294 PAINTED T2 P3 PAINTED T2 P3 PAINTED T2 P3 DATE` FEBRUARY 2015 5 UPRIGHT INSTALLATION DETAIL SHEET 4 INTERIOR ELEVATION A2.1 SCALE: 1 1/2" = 1'-0" @ METAL SHELF UPRIGHT A2.1 SCALE: 1/4" = 1'-0" @REAR SALES WALL SHOE WALL A-2m FASTEN HOOKS TO FITTING ROOM WALL W/(2)1-1/2" FINISHED CEILING FINISHED CEILING SCREWS AT ENDS& _ Q CENTER SUPPORT TO m ZD U. A B D SUPPORT 50LB LOAD ui s > F 31/8' GB1 GB1 GB1 GB1 P2 P2 P2 - 1x6 MDF TRIM 1x6 MDF TRIM 0 T1 P3 T1 P3 P2 2'-0" "' Q CLEAR SILICONE MOTION '• r , W 3'-6" 2'_0" CAULKING SENSOR---,, F- �• o AROUND MIRROR _ C) R \� w R _ _ = 24"x60"MIRROR � 1" MDF 1"MDF U � U FASTEN CORNER TRIM CORNER TRIM Q 2_0-1 X HOOKS CLEAR SILICONE o- // 3'-6" 2 TYP. SEE OOKS� T4 P3 Q T4 P3 J B1 - CAULKING AROUND ACCESSORY Q BENCH- ;�. 61 B1 / g1 BENCH- SEE DTL d Ln COVE BASE _ / SEE DTL SCEDULE 3/A-2.2 N THERMOSTAT IV 3/A-2.2 E'- SENSOR INSTALL I- M 1 FITTING ROOM WALL ELEVATIONS 2 w COO U MN AS EAR E OF _ FITTING ROOM HOOK DETAIL w A2.2 SCALE: 1/4" - 1'-0" „ _ = INDICATED ON = N A2.2 SCALE: 1/4 = 1 -0 Z SHEET M1. SEE 5/M2 0 T E EQ FOR SECURING Z J DETAIL. g w Q V♦ M FINIS -I LEGEND O SEE SHEET T-1 & FINISH SPECIFICATIONS v V/ O O NO. MA ERIAL MANUFACTURER SPECIFICATIONS `- o O . GB1 FINISHED GYP BD. "LOCAL" 8'-0"x 4'-0"x 5/8" (1/2"AS SPECIFIED) O Q Q Ya"SILICONE BEAD BETWEEN Z W v w PLYWOOD AND GYPBD WALL. P2 PAIN SHERWIN WILLIAMS "BAGEL"#SW6114 w U) w Lu} 2x2 WOOD SUB-FRAME P3 PAINT SHERWIN WILLIAMS "STRUCTURAL GRAY"#SW4031 w W w w od ARPET OVER PLYWOOD F1 P4 PAIN - RESTROOM(S) SHERWIN WILLIAMS "ETHEREAL WHITE"#SW6182 O Q Q a H RADIUS CORNE VARIES CARPET OVER SW1 SLATWALL MODULAR WOOD HARD ROCK MAPLE MELAMINE w d w 3/a"PLYWD FACE. /4 PLYWOOD SEAT 0 ........... SW2 SLATWALL MODULAR WOOD HARD ROCK MAPLE MELAMINE (SHOEWALL) = COLUMN WRAPPED' ul 3 F1 f- COLUMN WRAPPED Z ' T1 MDF RIM "LOCAL" w W/MTL STUDS, GYP W/MTL STUDS, GYP O CONTRACTOR IS TO INSTALL FITTING ROOM BENCHLU 1 x 6 PRIMED MDF (PAINT GRAY P3) O BD, &SLATWALL BD,&SLATWALL "BLACK"JOHNSONITE MODEL VCD CARPET TILES i• ( ' T2 MDF RIM "LOCAL" 1 x 4 PRIMED MDF PAINT GRAY P3) O SW1 STAIR NOSING @ EDGE OF FITTING �' ________ ( � SW1 TUCK CARPET TILES " T ROOM BEN BENCH.ATTACH WITH T3 MDF ORNER TRIM "LOCAL" 1 x 2 + 1 x 2 PRIMED MDF CORNER TRIM PAINT GRAY P3 BLACK 1-5/8 #7 SCREWS 8"-10" INTO NOSING - - _____[2x2xl/4" ________ _ ( ) Q; (j APART.INSTALL CARPET TILES ON - 6x16 GA. CONT.STL. T4 MDF CORNER TRIM "LOCAL" 1 x 1 ONE PIECE MDF CORNER TRIM (PAINT GRAY P3) p BENCH AND TUCK CARPET EDGE 15/161 r r' BAND ON MTL.STDS. CQ N U INTO STAIR NOSING AS SHOWN. �' r, 4BASE (STRAP BACKING T5 MDF CORNER TRIM "LOCAL" 1 x 3 + 1 x 2 PRIMED MDF CORNER TRIM (PAINT GRAY P3) ui LiJ F. M BEHIND GYP.BD.) ( r JOHNSONITE MODEL VCD STAIR NOSING FRP FRP ANELING "LOCAL" TO 48"AFF ON ALL TOILET ROOM WALLS Q 23 FINISH TYP.@ 3 SIDES 1x4 MDF TRIM 1x4 MDF TRIM co W OU m d1- PLY PLYWD SHEATHING "LOCAL" 4'-0"x 8'-0"x 1/2" FRT PLYWOOD T2 P3 TUCK CARPET TILES INTO NOSINGV I FLOOR MTL.ANGLE T2 P3 LLL Z Q = N CARPET TILES (TYP.@ SIDES)FASTEN co g = FITTING ROOM BENCH TO WALLS W/3/8" LL! TOGGLE BOLTS @ 9"O.C. " 1 1 Z Q o 2 2 FINISHED FLOOR FINISHED FLOOR o Z F + 'I 'I + MTL STUD ATTACHED CO m U` N En OU (Bj ;� SALES AREA t TO SLAB @ 16"O.C. ,IN FULL LENGTH OF BENCH T1 `t �, �N 9 TYPICAL COLUMN ELEVATION 10 TYPICAL COLUMN ELEVATION BEHIND Ya"PLYWOOD 1x6 PRIMED MDF T3 SALES AREA �\ A2.2 SCALE: 3/4" = V-0" W/SENSOR A2.2 SCALE: 3/4" = V-0" O 3 FITTING ROOM BENCH DETAIL FACE. iX2 PRIMED nMFD TRIM W/ T5 c� c� w w o w " , " ., FINISHED CEILING p Q W p a, W A2.2 SCALE: 1-1/2 - 1 0 1x3 PRIMED MDF FACE W/ (6 } W F- Z ZZO � Z -� � W Z 1x2 PRIMED MFD TRIM "-A INSTALL 1/2"FRT PLYWOOD WITH LIQUID cn L U O W w u- U- O 2 z XXZm0Z maw NAIL& HEXHEAD TAPCON SCREWS @ 24" w w w LL Q T2 L 1x4 PRIMED MDF Ill LU T4 ALL TRIM PAINTED P3 O.C. DIRECTLY TO WALL. 0 -� Z Ha W m Z = W 1x1 PRIMED MDF VARIES Q EL- 3: � Q = p OUTSIDE CORNER TRIM W WWQ' O 8'-0" Q LL U m g _'jz b_ U) Z --SLATS -� ---SLATS 13 TRIM SCHEDULE v4°HEXHEAD TAPCON co w Q o U W (n m U w U - �� SCREWS W/SS WASHER @ > n_ o m z O O w A2.2 SCALE: 3 - 1 -O 24 O.C. EACH WAY, MINIMUM w F- Z I-- O z ate. L 8 SCREWS PER 8'-0"SHEET O O0 U Q Z o C7 w m W � Z) Z2 ZI- Z ACCESSORIES SCHEDULE ACCESSORIES SPECIFICATIONS w W Fn>_ oz � � 1 N. PLY o W � ¢ w - ((nZO co <-37 MR # MANUFACTURER DESCRIPTION MODEL NO. REMARKS ACCESSORIES 0 LL o 0° w ~ = W z W as ° `� ZUm SHOE WALL SLATS TO BE LEVEL LL X - w - 1 BOBRICK SINGLE ROLL TOILET TISSUE HOLDER B-7685 SURFACE MOUNTED 1. TOILET ROOM ACCESSORIES (SEE ACCESSORIES SCHEDULE ON SHEET A2.2 TOILET Z °- H z O O W C _ = w FROM PANEL TO PANEL. Tr � O O a O Fs 2 DEB SBS WALL MOUNTED FOAM SOAP DISPENSER PROLINE CURVE HIBBETT PROVIDED PAPER HOLDER SUITABLE FOR SINGLE ROLL 24X36 MIRROR-CLEAR SILICONE AROUND 1 p vi Z O O Z O z SLATS TO BE SLATS TO BE PERIMETER GRAB BAR'S(AS REQUIRED PER CODE)PAPER TOWEL HOLDER SUITABLE FOR 1: 0 w z F- z ~ O� w ~ w LEVEL ACROSS LEVEL ACROSS R' 1 BOBRICK MIRROR-CHANNEL FRAME-24"X 36" B-165 2436 APPLY CLEAR SILICONE CAULK AROUND PERIMETER SINGLE ROLLS ADA HANDICAP REST ROOM SIGNAGE. cn Z I- g U Q W U U H Y THE UPRIGHT THE UPRIGHT 1 *CUSTOM CUT* MIRROR- FRAMELESS-24"X 60"X 1/4" N/A INSTALL PER SHEET A-2.2 DETAILS O z U 0 0 W _ � U w 1- p ¢ = � UO � � � pU R -; *CUSTOM CUT* MIRROR- FRAMELESS-8"X 60"X 1/4" N/A INSTALL PER SHEET A-2.0&A-2.2 DETAILS 2. FITTING ROOM ACCESSORIES (SEE ACCESSORIES SCHEDULE ON SHEET A2.2)FITTING (, to Q m Z T- m cn w z w w R 1, *CUSTOM CUT* MIRROR- FRAMELESS-24"X 60"X 1/4" N/A INSTALL PER SHEET A-2.1 &A-2.2 DETAILS ROOM HOOKS 24 x 60 X 1/4" MIRROR SHALL BE LOCATED ON INSIDE WALL OF THE FITTING w W U Q co z 0 L O w Z W 2 ROOM. SEE ELEVATIONS ON SHEET A2.2. CONTRACTOR TO SEAL AROUND PERIMETER OF 11 � Q O m - U U O 2 Gai 1 BOBRICK GRAB BAR(36") B-6806 X 3 INSTALL PER CODE REQUIREMENT PLYWOOD SHEATHING TYP F O U) m cU m p GB 1 BOBRICK GRAB BAR(42") B-6806 X4 INSTALL PER CODE REQUIREMENT FITTING ROOM MIRROR WITH CLEAR SILICONE.24 X 60 X 1/4"PI GLASS MIRROR SHALL BE " _ � „ �-- m vUi V O O � z O m p W z0 U A2.2 SCALE: 1/4 - 1 -0 z 0 0 LOCATED ON OUTSIDE OF FITTING ROOM DOOR.ALL MIRRORS WITH BOTTOM CHANNEL w I- I- _� F_ w H O 1, BOBRICK VERTICAL GRAB BAR(18") B-6806 X 1 INSTALL PER CODE REQUIREMENT AND MASTIC. MOUNT WALL MIRROR AT 12"A.F.F. MOUNT FITTING ROOM DOOR MIRROR O Z � D D w � e w O U P 2` "LOCAL" SINGLE ROLL PAPER TOWEL HOLDER "LOCAL" SURFACE MOUNTED CENTERED ON DOOR LEFT TO RIGHT AND 12"A.F.F.AS WELL. z z z m m � E2 CL Q W O FASTEN BAR TO FR. O 0 0 0 - Z) W w I- x w WALL WITH STANDARDS 2 BRADLEY ROBE HOOK(FITTING ROOM HOOK) 9119 INSTALL PER SHEET A-2.2 DETAILS U s' o U U U z U) > (n w a. WOO 2 TFtIMCO WALL DOOR STOP-STAINLESS 1270CV-SS INSTALL PER SHEET A-2.0&A-2.1 DETAILS 1-1/2"1-1/2" D BLOCKING W/(2)1-1/2"SCREWS AT 4 F -- IVES FLOOR DOOR STOP-STAINLESS FS13-DOM : INSTALL PER SHEET A-2.0 DETAILS ENDS AND CENTER LEVEL SLATWALL ELEVATION NOTE:A2.2 SCALE: 1/4" SUPPORT TO © COPYRIGHT 2014 = 1'-0° {TYP) NOTE: SUPPORT 2501bs.LOAD HIBBETT SPORTING GOODS, INC 1. CONTRACTOR SHALL INSTALL BLOCKING IN WALLS AT INDICATED LOCATIONS OF TOILET ACCESSORIES. GRAB BAR{MUST 2. CONTRACTOR SHALL INSTALL EQUIPMENT PER MANUFACTURES SPECIFICATIONS (CONTRACTOR SHALL NOT ROTATE IN REVISIONS: INSTALL PER A.D.A MOUNTING HEIGHTS REFER TO MANUFACTURE SPECIFICATION SHEETS) SLEEVE 1 BD COMMENTS 04/02/15 3. ALL TOILET ACCESSORIES ARE TO BE AS SPECIFIED OR APPROVED EQUAL.VERIFY ALL ACCESSORIES WITH HIBBETT CONSTRUCTION DEPARTMENT PRIOR TO PURCHASE AND INSTALLATION. u. LL Q is 1x10 FURRING STRIPS 1x10 FURRING STRIPS SATIN FINISH- ALUMN.GRAB BAR GRAB BAR DETAIL FREDERICK J. GOGLIA ARCHITECT,NCARB,RDI A2.2 ' SCALE: 3" = 1'-0" 0 1950 C114n ROAD,SUITE 300 Sr.LOUIS,MO haws PR(314)415-2400 FAX(314)415-2300 vYww.ercvcam CONT. DOWN - - - - - - - - C7 CONT. DOWN - - - - - - - - C9 Z z STANDARDS(TYP.) z z HIBBETT G.C.TO STANDARDS (TYP.) p EEO O w O - - - - - - - - u- - - - - - - - LL W - INSTALL CLEAR 7'-6" - - - - - - - - ry CAULK AROUND ; IWi Q - - - - - - - ¢ Q MIRROR ) SLATWALL w O SLATWALL w Oy W Z Z - - - - - - - W Z FASTEN PAPER TOWEL&TOILET 7"-25" SW1 m O _ SW1 = O ? TISSUE HOLDERS TO FR.WOOD P4 - ; J Q d J (n Q a BLOCKING W/(2)1-1/2"SCREWS AT ,� fry Q W > Q W > ENDS AND CENTER SUPPORT TO 8" IN �" r - Z (n W m Z (n w (/� SUPPORT 501bs.LOAD. PTH / FSD GB1 GB O O R1 Id _ ' (n FASTEN WALL-MOUNTED SOAP o ° L 1, jDISPENSER TO GYP BD W!2 °O Z ¢ Q Z I I TOGGLER BRAND SELF-DRILLING I: DRYWALL ANCHORS AND 2#8 x 1 1/2" 3 FRP BOTTOM OF I I ce N NSHEET METAL SCREWSBOTTOM OF SLATWALL a 5 SLATWALL - j IV-IN t NOTE:ALL WALLS IN TOILET ROOM 6" MAX 1"MIN 150142 TO BE PAINTED SEMI-GLOSS: fl, 30"CLEAR INTERIOR DETAILS&SPECIFICATIONS "P4-ETHEREAL WHITE'. 15" .�r 1�c. 48" CLEAR FLOOR LOCATION: # 1294 13 ACCESSIBLE DRINK FOUNTIAN ELEVATION DATE: FEBRUARY 2015 5 TRAINING AREA TYP 6 MANAGER'S AREA TYP 7 TOILET ROOM INTERIOR ELEVATIONA2.2 SCALE: 1/4" = 1'-0" SHEET A2.2 SCALE: 1/4" = 1'-0" A2.2 SCALE: 1/4" = 1'-0" A2.2 SCALE: 1/4" = 1'-0" A�202 NOTE: CARPET TO EXTEND T-0"INTO STOCK AREA CONC. SLAB, VINYL EDGE GUARD REQUIRED SLAB MOISTURE AND ALKALINITY ROOM FINISH SCHEDULE _! CARPET CONC.SLAB CARPET CARPET VINYL EDGE GUARD SEALED F3 - /--VCT FLOORING F4 F1illilrillillilliF1 F1 CONC. SLAB, TESTING: SPACE FLOOR BASE WALLS REMARKS Q LL SEALED AillillillI MTL THRESHOLD CONC. SLAB CARPET TILES W/ BASE TRIM GYP BD TAPED, FLOATED, SANDED PAINT TRIM PER ELEVATIONS ON W F3 1. BEFORE INSTALLING INTERFACE GLASBAC/GLASBACRE CARPET TILES OVERA NEW OR VINYL PLANK AISLES 1x4 MDF, PAINTED SMOOTH, W/FURRING STRIPS SHEET A2.1. INSTALL PROVIDED °' - - - °4° - 'B ° - '° 4 •' 8... • - °C °' °, ° ° - .� °d' ° a.°' ;,,. c-° EXISTING CONCRETE SUB-FLOOR, YOU MUST TEST THE MOISTURE AND ALKALINITY INSTALLED PER SHEET A2.3. SLATWALL AND SHELF STANDARDS. ° LEVELS OF THE CONCRETE. CARPET TILE-INTERFACE TOP TRIM SLATWALL AND SHELF STANDARDS - d °.q - �° � �- '� d .° ° a a °ad � ° � 4� �.°d` d -° °° � - °d M 2. MOISTURE CONDITIONS OF THE CONCRETE SHOULD BE DETERMINED BY USE OF THE IN STYLE # 19S5302500 1x6 MDF, PAINTED INSTALLED OVER FURRING. SITU PROBE RH TEST METHOD(ASTM F 2170). COLOR # 175428 SLATWALL-MODULAR WOOD W CARPET/CARPET SALES TO STOCKROOM CORRIDOR TO EXIT CORRIDOR SALES COLOR HARDROCK MAPLE AREA VINYL PLANK-ARTISTRY PLANK SLATS 3"O.C. 2 FLOOR TRANSITION 3 FLOOR TRANSITION 4 FLOOR TRANSITION 5 FL OR TRANSITION 3. MOISTURE CONDITIONS MUST NOT EXCEED 75%RH EXCEPT WHEN INSTALLING WITH 100 STYLE #ST6519-HICKORY SW1 48"x46-15/16" TACTILES®CONNECTORS OVER NEW OR BARE A-3 SCALE: N.T.S. �-3SCALE: N.T.S. A-3 SCALE: N.T.S. A-3 SCALE: N.T.S. ° SW2 4'x8' uiui CONCRETE,WHICH ALLOWS FOR INSTALLATION UP TO 80%RH. ENTRANCE MAT-INTERFACE 1 CONTACT JERRY DENENBERG 4. ALL CONCRETE FLOORS, OLD AND NEW, SHOULD BE TESTED FOR ALKALINITY BY USING STYLE #7187 PH: (561)336-3777 COLOR BLACK METAL STANDARDS-IMPRESSIONS AN ALKALINITY TEST KIT.THE PH TEST PAPERS SHOULD BE CAPABLE OF MEASURING A STYLE HS-12UP-C(12'STANDARD) v v BLACK RUBBER RANGE OF 0-14. CONTACT PAUL HILL Q CARPET CARPET ENTRANCE MAT VINYL PLAN J-STRIP U ENTRANCE MAT ENTRANCE MAT PH: (866)975-04444 J F1 VINYL PLANK F1 F5 FLOORING F2 5. THE AREA TO BE TESTED MUST BE WEATHER-TIGHT AND CONDITIONED,VIA THE CONC.SLAB F2 FLOORING CONC.SLAB F5 CONC. SLAB MTL THRESHOLD CONC. SLAB F5 BUILDING'S HVAC SYSTEM,TO A TEMPERATURE RANGE OF 65°-85°FAHRENHEIT ANDA O FINISHED CONCRETE SEALED 1 N/A GYP. BD.TAPED, FLOATED,SANDED WALLS TO BE UNFINISHED. INSTALL z z 111IFRELATIVE HUMIDITY RANGE OF 40%-60%.THIS TEMPERATURE AND HUMIDITY RANGE STOCK WEEK PRIOR TO TURNOVER SMOOTH. INSTALL FURRING WHERE STOCKROOM SHELVING PER A2.0 d- : - . r7 7 -. d` ' °: T'HE TESTUST BE , AT ALDL TIMES FOR STDURING THE TEST.HOURS IMMEDIATELY PRIOR COMMENCING SHELVING IS INSTALLED.SEE IRECTION. d? °. ..°. .. ° v .. e. - ° °, - L a .° ;°e... ° :° .° a - .°. o - AREA SHEETS A2.0,OBE&A2.3FORDETAIL5 D RIO CI Q /r M 6. ALL ADHESIVES, COATINGS, FINISHES, DIRT, CURING COMPOUNDS,SEALANT AND OTHER CARPETNINYL PLANK ENTRANCE MAT/SALES ENTRANCE TO MAT ENTRANC MAT/SALES SUBSTANCES THAT MAY AFFECT THE RATE OF MOISTURE DISSIPATION MUST BE TOILET VCT-MANNINGTON BASE-LOCAL GYP. BD.TAPED, FLOATED,SANDED WALL FINISH: PAINTED W/SHERWIN N REMOVED FROM THE AREA TO BE TESTED. ROOMS STYLE ESSENTIALS FRP TO 48"AFF SMOOTH. PAINT WALLS W/SHERWIN WILLIAMS SEMI-GLOSS LATEX PAINT T ,yam COLOR # 112 PEWTER WILLIAMS LATEX SEMI-GLOSS AS SPECIFIED. INSTALL CLEAR 6 FLOOR TRANSITION 7 FLOOR TRANSITION $ FLOOR TRANSITION 9 FLOOR TRANSITION 7. NON-CHEMICAL METHODS, SUCH AS ABRASIVE CLEANING OR BEAD BLASTING MAY BE 102 "P4-ETHEREAL WHITE" SILICONE CAULK AROUND MIRROR _ USED ON EXISTING SLABS TO ACHIEVE AN APPROPRIATE STATE FOR TESTING. 103 � A-3 SCALE: N.T.S. A-3 SCALE: N.T.S. A-3 SCALE: N.T.S. A 3 SC LE: N.T.S. 31 AND COVE BASE. NOTE: CARPET TILE-INTERFACE BASE-LOCAL GYP. BD.TAPED, FLOATED,SANDED INSTALL CLEAR SILICONE CAULK TEST RESULTS REFLECT THE CONDITION OF THE SLAB AT THE TIME OF TESTING.INTERFACE FITTING STYLE #19S5302500 4"COVE BASE SMOOTH. PAINT WALLS W/SHERWIN AROUND COVE BASE&MIRROR. RECOMMENDS THE USE OF MOISTUREGARDTm 2.0 PRIOR TO INSTALLATION OF THE CARPET ROOM COLOR #175428 BLACK WILLIAMS LATEX SEMI-GLOSS n WHEN MOISTURE AND PH CONDITIONS ARE OUTSIDE SPECIFIED LIMITS.MOISTUREGARD 2.0 104 "P2-BAGEL" W WOM ENS PROVIDES PROTECTION AGAINST MOISTURE VAPOR EMISSION RATES OF UP TO 90%RH AND PH UP TO 12.0.WHEN MOISTUREGARD 2.0 IS USED,THE CARPET Q w TLT ROOM MUST BE INSTALLED WITH INTERFACE TACTILES CONNECTORS. FINISHED CONCRETE SEALED 1 BASE-'LOCAL GYP. BD.TAPED, FLOATED,SANDED WALL FINISH: PAINTED W/SHERWIN c Lu MENS CORRIDOR WEEK PRIOR TO TURNOVER 4"COVE BASE SMOOTH. PAINT WALLS W/SHERWIN WILLIAMS SEMI-GLOSS-P4"ETHERAL a F- TLT ROOM 102 LANDLORD NOTE: BLACK WILLIAMS LATEX SEMI-GLOSS WHITE". 0- � 105 "P4-ETHEREAL WHITE" a 103 T-5" T-6" 6'-4" 38'-0" CONTACT DAN JOSTEDT OF IFTI @ 1-800-490-3657 EXT.206 FOR INDEPENDENT TESTING. Q w 0 z 0 • • 3'-0" 3'-0" FINISH LEGEND C7 SEE SHEET T-1 & FINISHSPECIFICATIONS H m F4 F4 �,d X-0" 4'-0" 4'-0" 0 4.. NOTE: 4„ t) FRP FRP CONTRACTOR SHALL LINE UP VINYL ,� z O PLANK WHEN MAKING TURN.JOINT NO. MATERIAL MANUFACTURER SPECIFICATIONS N o OVERLAP TO BE DETERMINED UNDER Q 5 5 FIELD CONDITIONS TO ALLOW THE MOST \ B1 COVE BASE JOHNSONITE BLACK W W F- M A3 A3 1° I� I USE OF MATERIALS. I� J � N F2 ELECTRICAL M t w rn 3'-0" STUB-IN(S) I I F1 CARPET TILES INTERFACE STYLE#19S5302500 COLOR#175428 ; 0) O Q m N • 1.. F1 F1 • 8'-11" 12'-0" 4 112 9'-0" 2'-7" I F2 VINYL PLANK FLOORING ARTISTRY PLANK "ARTISTRY PLANK"#ST6519-HICKORY F- g Q = A3 A3 0 2ch '_g � 10 F1 _ F2 \ , 3 I '4 r6 � I F2 I F3 CONCRETE SLAB "LOCAL" CLEANED&SEALED 1 WEEK PRIOR TO TURN OVER W z Q n CORRIDOR �,� (VCT) 112 PEWTER _ Q oa Z F3 M F1 io F2 / \ A3 F1 I I F1 F4 VINYL COMP.TILE VCT MANNINGTON o F5 ENTRANCE MAT INTERFACE ENTRY LEVEL(WALK OFF): STYLE: 7187 COLOR: BLACK (D N m �V @l s ------ - - - - - � F2 / A3 I F2 M F2 ti N I # "' i ROOM FINISH SPECIFICATIONS (V cV a0U- wr ❑ wl- 6 \\ F1 g F1 O pPZ0QW OaW \ LL w w02 2'-6" A3 2'-6" VINYL PLANK ORIENTATION A3 `• Z X X - m O w ( ~ 1" 2-6 TO TURN 90°AT CORNER A. GENERAL w w w z w z m 0_ (TYP• 22-102 3,_p^ - LOCATIONS. 1. GENERAL CONTRACTOR WILL PROVIDE ALL LABOR NECESSARY FOR THE APPLICATION OF THE z w ❑ ❑ w ❑ = d VARIES SPECIFIED FLOORING. ❑ - LL w m Q p 2. ALL SURFACE PREPARATION, APPLICATION AND FINISHING SHALL BE IN STRICT ACCORDANCE w w w O U ~ z WITH MANUFACTURER'S INSTRUCTIONS. Q L>L U = g z ❑ rio VINYL PLANK INSTALLATION 3. PROVIDE SEALER(2-3 COATS)AS REQUIRED FOR ADEQUATE PROTECTION&FINISH IN U ~ U Q m m U W U �-3SCALE: 3/8" = V-0" cn w 0 Lu STOCKROOM ONLY > w ❑ m O z 0 w 5 F1 4. G.C.TO PROVIDE,VINYL WOOD FLOORING, CERAMIC TILE,AND/ORVCTAS NOTED ON SHEETS Lu O = Q O~ H - a u �N T1 AND A3 0 ~ � Z) I--� Zz2 zHz �` w ❑ 0 Y B. VINYL COMPOSITION TILE: W z t z m � m ¢ O 1. ALL DESIGNATED FLOORS SHALL RECEIVE VINYL COMPOSITION TILE AND 4 VINYL BASE. TILE �- Q w m z O &BASE SHALL BE SET IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS. 0 LL m a w c9 = w } 2. V.C.T.: MANNINGT.ON ESSENTIALS,#112 PEWTER z n aj - w ❑ `n 0 z U m O F2 3. BASE: JOHNSONITE"LOCAL BLACK" 0 t Oz ❑ Oo w w Q _ LL m - = zw I- 5'-0�" C. CARPET: O m > z cn O 0 O� 0 m z 0 Z STOCK AREA s te = a w Z P Z o w o � w - 1. MANUFACTURED BY INTERFACE CARPET TILES AS SPECIFIED BELOW z 2 U Q w U � Y 2 SALES AREA 6 -1°0 Q cn — cn - � � = � v0 � w 101 `� 2. SPECIFICATIONS - z � z F2 M A3 N InterfaceFLOR"HIBBETT SPORTS CUSTOM" ADDRESS. ~ 0 � 2 ❑ Oz � U ❑ � ¢ X 0 z F3 100 (Typ) 0D " 50cm x 50cm CARPET TILE INTERFACE SERVICES V w w cn Q cn z ❑ w O z � 1„ �; STYLE: 1955302500 106 NORTHPOINT PKWY Q g tY Q m U 0) 0 0 O0 F1 2'-6" 10-78 4'-0" = COLOR: 175428 BLDG 2, SUITE 300 U O O m z a m p oz U 3. COORDINATING PRODUCTS: ACWORTH, GA 30102 ~ w cn o 0 Lu w I-- 9 InterfaceFLOR TacTiles: CONTACT: KRISTA LEWIS z -- O p p — `L O ❑ A3 CARPET TILE INSTALLATION SYSTEM PHONE: 770-975-4810 Q ~ z z z z m m x iE a U O 125 sq YARDS PER BOX EMAIL: KRISTA.LEWIS INTERFACEGLOBAL.COM O O O O m 0 w w 1¢ X x @ (� � ❑ UUU = cn � > wxcnwEL fV D. VINYL PLANK FLOORING-CONTACT KRISTA LEWIS @(770)975-4810 FOR ORDERING F2 IIIII F5 Til I I o 8 FLOORING:'"ARTISTRYPLANK" II I I ih A3 STYLE:#ST6519-HICKORY © COPYRIGHT 2014 3'-0"ELECTRICAL CLEARANCE _ _ � ` HIBBETT SPORTING GOODS, INC STRIPING AS DIRECTED BY E. CERAMIC TILE LOCAL FIRE MARSHAL,MINIMUM N DALTILE P48891525 ASPEN IN 12"X 12"TILES, UNLESS OTHERWISE NOTED. REVISIONS: 3"STRIPING, OSHA YELLOW 7 BASE: DALTILE P48891525 ASPEN IN 6"X 6"TILES, UNLESS OTHERWISE NOTED. 2'-6" 2'-6" A3 GROUT-HIBBETT"DEI^OURIAN GRAY"#165 1 BD COMMENTS 04/02/15 2'-6" F. ENTRANCE_MAT-CONTACT KRISTA LEWIS @ (770)975-4810 FOR ORDERING r InterfaceFLOR ENTRY LEVEL:(WALK-OFF) CID / g 50cm x 50cm CARPET TILE cv iv l A3 STYLE: 7187 COLOR:PLACK \ (F'/P) 2'-6" G. VINYL COVE BASE-CORRIDOR, & FITTING ROOM (SEE FITTING RM.ELEV.ON A2.2) FREDERICK J. GOGLIA F2 \\ JOHNSONITE-TIGHTLOCK CARPET WALL BASE,"LOCAL BLACK" ARCHITECT,NCARB,RDI M 1950 CRAIG ROAD,SUITE 300 ST.LOUIS,MO 63146 6 A3 H. REDUCER STRIP PH(314)415-2400 FAX(314)415-2300 wwwsrcvcom JOHNSONITE-COLOR VATCH CTA-40-A cv / 10 N CARPET TO TILE ADAP ER 2650-471 3 \ A3 (21 A3 0 2'-6.. 4 c%) F1 25'-102" _ A3 CONTRACTOR'S NOTES: F2 , F1 6 B1 A3 1. REFER TO RESPONSIBILITY SCHEDULE ON SHEET T-1. F_ 3'-6" 3 2. ALL PERIMETER MEASUREMENTS ARE SHOWN FROM THE SLATWALL FINISH. 1' a F1 iv 3. ALL TRANSITION AISLE MEASUREMENTS ARE SHOWN FROM - - - - --" - - ----------`------------1---�-� �----- THE CENTER OF THE TRANSITION STRIP. 150142 FITTING 6'-0" 6'-4" 13'-01 28'-118" FLOOR FINISH PLAN ROOM LOCATION: # 1294 104 SEE FITTING ROOM BENCH 118" DATE: FEBRUARY 2015 NOSING DETAIL 3/A2.2. SHEET 1 FLOOR FINISH PLAN A-3 SCALE: 3/16" = V-0" A�3 REFLECTED CEILING NOTES: REFLECTED CEILING LEGEND LIGHT FIXTURE SCHEDULE LAMP SCHEDULE J - REFER TO RESPONSIBILITY SCHEDULE,SHEET T-1. 4'-0"STRIP FLUORESCENT LIGHTQTY SYMBOL TYPE MANUFACTURER CATALOG NO. DESCRIPTION VOLTS REC SUR SUS WAL REF LAMP/ WATTS/ FIXTURE MANUFACTURER/ Q FIXTURE -STOCKROOM STRIP LIGHTS MUST BE INSTALLED PER MEASUREMENTS SHOWN LAY-IN FLUORESCENT LIGHT FIXTURE --+ ® EXHAUST FAN NOTES FIXT LAMP WATTS CATALOG NO. W .. ON THIS SHEET. FAILURE BY RESPONSIBLE PARTY TO FOLLOW THIS 2GR8428T8A-UNV RECESSED FLUORESCENT 2x4 SYLVANIA DIRECTION SHALL RESULT IN RE-INSTALLING THE FIXTURES AT THE EXPENSE ® 44 A METALUX QHE4X28T8/UNV 1,5 UNIV X 4 28 95 OF THAT PARTY. ® yy LIGHTED EXIT SIGN ISNSCU-CLP WITH ACRYLIC LENSE F028/835/XPSS/ECO (D > LAY -IN UNLESS OTHERWISE SPECIFIED, EXIT LIGHTS ARE TO BE CEILING MOUNTED. EMERGENCY LIGHT FIXTURE 2GR8428T8A-UNV RECESSED FLUORESCENT 2x4 SYLVANIA FAILURE BY RESPONSIBLE PARTY TO FOLLOW THIS DIRECTION SHALL RESULT9 B METALUX QHE4X28T8/UNV WITH ACRYLIC LENSE EMERG/NL 1,2,3,5 UNIV X 4 28 95 IN RE-INSTALLING THE FIXTURES AT THE EXPENSE OF THAT PARTY. 2'x2' PLEXI B BBLE FOR SECURITY ® SUPPLY AIR DIFFUSER ISNSCU-CLP-EL4 ( ) F028/835/XPSS/ECO -UNLESS OTHERWISE SPECIFIED, EMERGENCY LIGHTING IS TO BE BUILT-INTO FIX STRIP FLUORESCENT LIGHT FBISYSTEM WN228T8A UNV U THE FLORESCENT NIGHT LIGHTING SPECIFIED ON THE PLAN. FIXTURE SURFACE MOUNT FLUORESCENT SYLVANIA W ISNSCU-CLP -ALL NEW LIGHT FIXTURES THROUGHOUT SPACE MUST HAVE NEW LAMPS 3 ® C METALUX QHE2X28T8/UNV 1X4 WITH ACRYLIC LENSE 1,5 UNIV X 2 28 48 F028/835/XPSS/ECO \ INSTALLED. 8'-0"STRIP FLUORESCENT NIGHT LIGHT 2'x4' MIRROR -D PANEL FOR RETURN AIR GRILLE SSF128-UNVOS / -2 X 2 MIRRORED BUBBLES INSTALLED ACCORDING TO TENANTS PLANS.SEE EMGERGENCY LIGHT FIXTURE SECURITY SY TEMSYLVANIA 3 --- F METALUX QHE1X28T8/UNV 4' FLUORESCENT STRIPLIGHT 1,5 UNIV X 1 28 25 ' ` ' SHEET A4 AND T1-RESPONSIBILITY SCHEDULE. F028/835/XPSS/ECO V V -2 X 4 MIRRORED PANELS INSTALLED ACCORDING TO TENANTS PLANS.SEE ISNSCU-CLP SHEET A4 AND T1-RESPONSIBILITY SCHEDULE. 8TSSF128-UNVOS 8'FLUORESCENT STRIPLIGHT SYLVANIA 6" 8 G METALUX QHE2X28T8/UNV (TWO 4'FIXTURES IN TANDEM) 1,5 UNIV X 2 28 48 F028/835/XPSS/ECO J ISNS-CLP 8TSSF128-UNVOS 8'FLUORESCENT STRIPLIGHT SYLVANIA Z Z FACE OF TRACK, 8 GG METALUX QHE2X28T8/UNV (TWO 4'FIXTURES IN TANDEM) 1,2,3,5 UNIV X 2 28 48 F028/835 XPSS/ECO M / 6"FROM FACE OF ISNS-CLP-EL4 (EMERG/NL) M 1= WALL 4'ONE CIRCUIT TRACK(WHITE) `' , UL 5 o K HALO LZR104P 1,5,6 120 X NOT APPLICABLE J U- MTD W/LZR207 T-BAR CLIPS N ELECTRICAL N TE Icn 8'ONE CIRCUIT TRACK(WHITE) -ALL LAY-IN LIGHT FIXTURES ARE NEW. _ z 11 o M HALO LZR108P MTD W/LZR207 T-BAR CLIPS 1,5,6 120 X NOT APPLICABLE N -ALL STRIP LIGHT FIXTURES ARE NEW. I T O Q Q M w MB CIRCUIT BREAKER 5A @ 120V -ALL TRACK LIGHT FIXTURES ARE NEW. I I SIGN HOLDER TRACK, w 1 ❑ N HALO CB600P 1,5,6 120 X NOT APPLICABLE -ELECTRICAL CONTRACTOR TO INSTALL NEW LIGHTING&CONNECT TO POWER ATTACHED TO BOTTOM =600 WATT(WHITE LIVE END) PER THIS LAYOUT. I I OF TOP TRIM OF z MB CIRCUIT BREAKER 1A @ 120V I I 0 4 ❑ NN HALO CB120P 1,5,6 120 X NOT APPLICABLE -CONTACT STEVE BENTRUP OF CITY LIGHTING PRODUCTS TO PURCHASE DISPLAY WALL w = 120 WATT(WHITE LIVE END) SENSOR SWITCHES AS NOTED ON PLAN @(800)888-2572. w MINIATURE STRAIGHT CONNECTOR DISPLAY WALL o 8 - P HALO LZR212P FOR SURFACE TRACK(WHITE) 1,5,6 120 X NOT APPLICABLE d cn W" ~ LIVE END FEED FOR SURFACE r m 6 ❑ R HALO 1,5,6 120 X NOT APPLICABLE I- LZR201P TRACK(WHITE) AM (� IZ 3 STOREFRONT DETAIL GIMBAL RING TRACKHEAD SYLVANIA 78440 ` 54 0 S HALO LZR338P 1,5,6 120 1 16 16 LED16PAR38/DIM�-4SCALE: 1-1/2" = 1'-0" "MIRRORED"SECURI (SATIN WHITE W/WHITE BAFFLE) 830/FL40/G3 Q Q PANEL(TYPICAL) 2GR82U6T8-UNV tet; a NEW EXHAUST FAN DIM, FROM FACE OF RECESSED FLUORESCENT 2x2 SYLVANIA 0 3 T METALUX QHE2X32T8/UNV 1,5 UNIV X 2 32 55 0 INSTALLED OVER SLATWALL TO FACE t12'-4"TRACK LIGHTIN 13'-112"TO FAC .OF SLATWALL ® ISNSC-CLP WITH PRISMATIC LENSE FB032/735 W. Z TOILET(TYPICAL) OF TRACK. ~ p EM SURE-LITES CC-2 DUAL-HEAD EMERGENCY LIGHT 1,3,5 UNIV X — — 15 INCLUDED W 2'X 2'RECESSED TROFFER _' � �N UNIVERSAL MOUNT LED EXIT LIGHT - ab PRISMATIC LIGHT FIXTURE 4 ® X SURE-LITES HALLPX70RWH 1 3 5 UNIV — — 3 INCLUDED LED ' ®� /d Z 1'-10" p` p _ M/NL A A T „ „ W/INTERNAL NICKEL CADMIUM BATT. C C N (TYPICAL FORT FIXTURES) Q o UNIVERSAL MOUNT LED EXIT LIGHT z NEW 4'SURFACE MOUNTED b 1 ® XX EXISTING EXISTING 1,3,5 UNIV X - - 3 INCLUDED LED •-+ O NN W/INTERNAL NICKEL CADMIUM BATT. [ cV U FLUORESCENT LIGHT G 12'OF SIGN HOLDER TRACK M FIXTURE(S)(TYPICAL z Q 1 ® Z BROAN MODEL#676 TOILET ROOM EXHAUST FAN 1,5 UNIV X — — 156 N/A W = J ❑ ® — — Q L CA FOR C RA Ivi ~ NN K P M K 1 ® ZZ EXISTING EXISTING TOILET ROOM EXHAUST FAN 1,5 UNIV X 156 N/A LI_I OU �_ MNL Y A D O M N co P J ai WALL MOUNTED OCCUPANCY In ~ g = rn MOTION SENSOR(S) Y —° 3 E� LEVITON ODS10-ID 1,5 ` UNIV X NOT APPLICABLE LLI (7 �} � X G U MOTION SENSOR z Q Ln EM L a� O REFERENCE NOTES: o g Z a X _I CLG HT @ 11--0-A.F.F. M ~ wwc d � O o 1. REFER TO RESPONSIBILITY SCHEDULE ON SHEET T1.Lu cV o0 U CdJ A A A A A T I-- +1 2. FIXTURES SHOWN ON PLAN TO BE WIRED TO NIGHT LIGHT CIRCUIT. 3. FIXTURES USED FOR EXIT OR EMERGENCY LIGHTING TO BE ON LOCKOUT SECURITY -_ _ w N T CIRCUIT. I RORED SECUR - - - M R --- -- 4 p ❑ U 4. CONNECTOR HAS ANGLED FEATURE.TURN FEATURE 90°TO CONNECT TRACK AT ANGLED PORTION.SEE PLAN FOR TRACK TO CONNECT 90° PANEL(TYPICAL) 5. CONTACT STEVE BENTRUP @ CITY LIGHTING PRODUCTS (800-888-2572) FOR PROCUREMENT OF ALL LIGHTING SPECIFIED ON THIS SCHEDULE. ION 6. ELECTRICAL CONTRACTOR MUST INSTALL/CONNECT ONE (1) DEDICATED CIRCUIT TO EACH FEED CONNECTOR @ TRACK LIGHTING. Uj O C9 u w >- ° w I- X NEW SOFFIT TO BE CREATED,,@ 9'-8"A.F.F. O i— z Ow Q � Ow Ow W CEILING MTD.EXIT GG G A A A PAINT WHITE TO MATCH `° cn m m O w w W r-- z XXF_ opOC9 ma. W LIGHT(S)(TYPICAL FOR EM/14L M/NL CEILING __._ w w w z u- z w a B J 12 OF SIGN HOLDER TRACK o -i Z w 13 0 m Q H 0- 0- "X"FIXTUR [X ES) M NN CEILINGFINISH SCHEDULE w ° ° w ° LA K C9 Q J w_ wFRo8 cc�n� _ z Y SPACE CEILING CLG HTJ REMARKS v v J z m � a 'gip p _ ACT CEILING-EXISTING FOR ORDERING INFO ON m w a m z O O W Z) C @ 9'- 1-A.F.F. �_ GRID 2'x 4' 2X2 MIRRORED BUBBLES w > U F- z a U_ M/N V o COLOR WHITE 2X4 MIRRORED PANELS p m_ C=g ¢ Z p _ C9 W Z F A A A B A A z SALES TILE REPLACE ANY BROKEN OR CONTACT- w � z z F- O O AREA VARIES, 0 w ° 0 z J O m p z C9 Y DASHED LINE(S)REPRESENT +1 �- w m START OF EXTENDED M M y 100 NEEDED D CEILING TILES AS SEE PLAN SE KURE CONTROLS v� z m U m �' O CEILING @ 9'-11"A.F.F. " (800}322-2435 EX: 1245 0 � Om m w 1- O = w z W NEW SOFFIT TO BE Q w Z O m +i z CREATED @ 9 8 A.F.F. (352)504-4342 w -5 ° a ° m z U m Q I 7T I ---I--- I I �l I I I I I I - - PAINT WHITE TO MATCH GSAPUTO@SE-KURE.COM z a z - o U X = m w 1= 00 Owa = = O rJ CEILING ACT CEILING-EXISTING FOR ORDERING INFO ON W T Fnz z w 0 w ° z O ~ 4'SURFACE-MOUNTEDON FLUORESCENT STRIP - 4'OF SIGN HOLDER TRACK LIGHT FIXTURE TYPICAL � _� GRID 2'x4' 0 cn > z cn O C7 � cn � z ( 2X4 MIRRORED PANELS = C9 Z z 0 z O w O w COLOR WHITE CONTACT- cn z U = w 0 C� U � w FOR"F"FIXTURES) NR STOCK AREA TILE REPLACE ANY BROKEN OR GREG SAPUTO @ O 0 � S ° 0 D U ° Q 0 z Ll A GG GG A DAMAGED CEILING TILES AS VARIES, SE-KURE CONTROLS Fn ° m U) vi ° z w H w EM/NL EM/NL M/N M/N 101,'; NEEDED SEE PLAN (800)322-2435 EX: 1245 V z ° cn z m z o w O x m w 2 DASHED LINE(S)REPRESENT Q w w Q Q O m U cn z 0 0 START OF EXTENDED B A A B 8'OF SIGN HOLDER TRACK EXTEND EXISTING CEILING GRIDS (352}504-4342 l O cn U O cn VO O WHERE SHOWN ON PLAN GSAPUTO@SE-KURE.COM Z 0 v z0 0z cn z w m p w z0 U CEILING @ 9'-11 3/4"A.F.F. z EXISTING SOFFIT @ 8'-10 3/4" z w w 0 ;_ 0 w w O 0 O GPY BD CEILING-EXISTING r ° ° w O W U A.F.F. PAINT WHITE TO MATCH O Y ❑ � r— � 8'SURFACE-MOUNTED ~ TOILET z z z z m W - O FLUORESCENT STRIP ! C7 ROOMS PAINT CEILING W/SHERWIN WILLIAMS m O J CEILING ; SEMIGLOSS"ETHERAL WHITE" "P4" 0 � 0 O O O = cn � > w w w a NIGHT LIGHT FIXTURE (2 1 B "MIRRORED"SECURITY 102 ACT CEILING-EXISTING 4'FIXTURES IN TANDEM) U 103 8= 1 W/EMERGENCY BACKUP G CLG HT @ 9'-11 /4"A.F.F. BUBBLE(3 TYPICAL) GRID 2'x 4' COLOR WHITE EXISTING CEILING MTD. C COPYRIGHT 2014 (TYPICAL FOR"GG" A A A A A A EXIT LIGHT TILE REPLACE ANY BROKEN OR O FIXTURES) I DAMAGED CEILING TILES AS HIBBETT SPORTING GOODS, INC B'SURFACE-MOUNTED 0.1 A ' NEEDED ACT CEILING-EXISTING REVISIONS: FLUORESCENT STRIP FITTING GRID 2'x 4' LIGHT FIXTURE(2 4' 7'-0" 5'-0" 2'-6" 4'OF SIGN HOLDER TRACK COLOR WHITE 9'-10" ROOM FIXTURES IN TANDEM) 104 TILE REPLACE ANY BROKEN OR PER DIMENSION (TYPICAL) NEW SOFFIT TO BE NEEDED101 DAMAGED CEILING TILES AS CREATED @ 9'-8"A.F.F. 5'-6" 6'-2" 2'-6" PAINT WHITE TO MATCH GRID X�ISTING 2X04 MIRRORED PANELS EXISTING CEILINGS TO BE iv R CEILING FREDERICK J. GOGLIA NN CORRIDOR TILEOR REPLACE ANY BROKEN OR COGREG TSAPUTO @ ARCHrrECT,NCARB,RDI TIED TOGETHER AS SHOWN GG G G 1EM/NL M/N EM/N11EM/NLM/N ¢ DAMAGED CEILING TILES AS 11'-0" SE-KURE CONTROLS IM CRAIG ROAD,8UrTE 300 ST.LOUIS,MO 63M B A B A B K z 105„1 NEEDED (800)322-2435 EX: 1245 PFL(314)415-2400 FAX(314)415-2300 www.arcv.com CEILING MTD.EXIT z (352)5044342 11 LIGHT(S)(TYPICAL FOR M z P O a GSAPUTO@SE-KURE.COM "X"FIXTURES) = B Y o Ll X Y P 0 CLG HT @ 9'-10"A.F.F. ~ w M G G I wq EM/N4 A _`r A A A A A w 1 -mak "MIRRORED"SECURITY u' U PANEL(TYPICAL) M ++ 12'OF SIGN HOLDER TRACK I p . C 2'X 4'RECESSED TROFFER PRISMATIC 61-0" NIGHT LIGHT FIXTURE W/EMERGENCY BACKUP(TYPICAL FOR"B"FIXTURES) � . 150142 �EFLECTED CEILING PLAN MOTION SENSOR DIM. FROM FACE OF SLATWALL ALL TRACK HEADS ARE TYPE 2'X 4'R CESSED TROFFER _ TO FACE OF TRACK. 'S"FIXTURES(TYPICAL), PRISM TIC LIGHT FIXTURE LOCATION: $ 1294 DASHED LINE(S)REPRESENT SPACED 24"O.C. (TYPICAL FOR"A" DATE: FEBRUARY 2015 START OF EXTENDED FIXTUR_S) CEILING @ 9'-10"A.F.F. SHEET 1 REFLECTED CEILING PLAN A-4 SCALE: 3/16" 1'-0" A�4 E HVAC SYMBOLS LEGEND AIR DEVICE SCHEDULE HVAC SPRINKLER KEYED NOTES J LL W ® SUPPLY AIR DIFFUSER THERMOSTAT/HVAC EXISTING HVAC UNITS TO REMAIN. MECHANICAL CONTRACTOR TO SERVICE ALL UNITS AND REPORT ANY PROBLEMS TO HIBBETT SPORTS CONSTRUCTION DEPARTMENT. > HARDWIRING *ME ALAIR FACE NECK FLEX n (DIF) MARK QTY MODEL NO. COLOR SIZE SIZE SIZE TYPE REMARKS O M.C. IS TO COORDINATE ALL INSTALLATIONS AND CONNECTIONS WITH THE ELECTRICAL CONTRACTOR. LANDLORD IS TO PROVIDE SPECIFICATIONS OF EXISTING UNITS TO v HONEYWELL PRESTIGE W/ HIBBETT SPORTS CONSTRUCTION DEPARTMENT. BALANCE SYSTEM TO VALUES SCHEDULED ON M{2. RETURN AIR GRILLE REDLINK THERMOSTAT M U A 15 73150-6 WHITE 24" x 24" VERIFY VERIFY DIF 1, 2, 3 2A NEW METALAIRE 7350-6 24"X 24"SUPPLY AIR DIFFUSER. INSTALL PER PLAN LOCATIONS&CONNECT TO NEW DUCTWORK. MODIFY DUCTWORK AS REQUIRED OR PROVIDE W (RAG) ® REDLINK INTERNET NEW AS SHOWN. GATEWAY(RIG) qq 1 EXISTING WHITE 24"x 24" VERIFY VERIFY DIF ` -- 3-BUTTON OVERRIDE 26 EXISTING 24"X 24"SUPPLY AIR DIFFUSER(S)TO REMAIN. CLEAN AND REPAIR DEVICE(S)AS NEEDED. MODIFY DUCTWORK AS REQUIRED OR PROVIDE NEW AS SHOWN. W ROOF TOP UNIT 0CONTROL B 7 RELOCATED WHITE 24" x 24" VERIFY VERIFY DIF 1, 2, 3 (RTU) 2C NEW METALAIRE 5800 12"X 12" SUPPLY AIR DIFFUSER W/T-BAR PLASTER FRAME TO BE INSTALLED 11N GYP. BD. CEILING PER PLAN LOCATION &CONNECT TO NEW > J S� ROOM SENSOR BB 1 RELO„ATED WHITE 24" x 24" VERIFY -- RAG 2 DUCTWORK. AIR DEVICE TYPE C 1 R:)-1 WHITE 24"x 24" VERIFY -- RAG 2 3A MECHANICAL CONTRACTOR TO SUPPLY AND INSTALL ALL MATERIALS NECESSARY TO RELOCATE NOTED SUPPLY AIR DIFFUSER(S)TO LOCATION SPECIFIED ON PLAN. CLEAN v z V NEW/EXISTING/ SS SUPPLY SENSOR OAND REPAIR DEVICE(S)AS NEEDED. MODIFY DUCTWORK AS REQUIRED OR PROVIDE NEW AS SHOWN. RELOCATED CC 1 5800 WHITE 12 x 12 VERIFY 6 0 DIF 1,4 TOILET ROOM ®S RETURN AIR SENSOR D 3 EXISTING !WHITE HITE 24"x 24" VERIFY -- RAG 36 MECHANICAL CONTRACTOR TO SUPPLY AND INSTALL ALL MATERIALS NECESSARY TO RELOCATE NOTED RETURN AIR GRILLE TO LOCATION SPECIFIED ON PLAN. CLEAN AND I ® EXHAUST FAN (EF) REPAIR DEVICE AS NEEDED. z 1 z EIM EQUIPMENT INTERFACE DD 1 RELOCATED 24"x 48" VERIFY -- RAG co MODULE (EIM) 4A NEW METALAIRE RP-1 24"X 24" RETURN OR TRANSFER AIR GRILLE. INSTALL PER PLAN LOCATION. Q Q CEILING MOUNTED E 2 R -1 WHITE 24"x 24" 10,10 -- TAG 1, 2 `_ � � HEATER ® HEATER THERMOSTAT 4B EXISTING 24"X 24" RETURN AIR GRILLES)DUCTED TO UNIT TO REMAIN. CLEAN AND REPAIR DEVICES)AS NEEDED. N NOTES: T �. �F FIRE DAMPER 1. PROVIDE SQUARE NECK TO ROUND ADAPTER AS REQUIRED O MECHANICAL CONTRACTOR IS TO INSTALL NEW REDLINK INTERNET GATEWAY(RIG) NEAR MANAGER'S DESK. SEE PLAN FOR GENERAL LOCATION. VERIFY FINAL LOCATION 2. FRAME SHALL FIT LAY-IN CEILING MODULE OF THERMOSTAT WITH HIBBETT SPORTS CONSTRUCTION DEPARTMENT PRIOR TO INSTALLATION. RIG TO BE CONNECTED TO NETWORK POD"3"AT MANAGER'S DESK. Q M 3. PROVIDE & INSTALL MANUAL VOLUME DAMPER 4. PROVIDE T-BAR PLASTER FRAME AS REQUIRED FOR GYP. BD. MOUNTING APPLICATION. O MECHANICAL CONTRACTOR IS TO INSTALL NEW HONEYWELL PRESTIGE WITH REDLINK THERMOSTAT NEAR RIG.THERMOSTAT IS TO BE WALL MOUNTED AS NOTED ON SHEET M2. SEE PLAN FOR GENERAL LOCATION. CONNECT EACH THERMOSTAT TO THE RECEIVING EIM PANEL FOR POWER ONLY, SEE 1/M2 FOR DETAILS.VERIFY FINAL * OR APPROVED EQUAL LOCATION OF THERMOSTAT WITH HIBBETT SPORTS CONSTRUCTION DEPARTMENT PRIOR TO INSTALLATION. THERMOSTAT TO BE CONNECTED TO RTU VIA 18/3 PLENUM Q SHIELDED STRANDED WIRE. VERIFY THERMOSTATS ARE COMPATIBLE EXISTING HVAC UNITS; OTHERWISE, PROVIDE& INSTALL INTERFACE EQUIPMENT AS NECESSARY. 7A MECHANICAL CONTRACTOR IS TO INSTALL NEW WIRELESS ROOM SENSORS COMPATIBLE WITH HONEYWELL PRESITGE WITH REDLINK THERMOSTAT. MOUNT AT HEIGHT LLI. NOTED ON COLUMN ELEVATION DETAILS (SEE DETAIL 9/A-2.2). SEE PLAN FOR GENERAL LOCATION. VERIFY FINAL LOCATION OF THERMOSTAT WITH HIBBETT SPORTS CONSTRUCTION DEPARTMENT PRIOR TO INSTALLATION. SEE DETAIL 5/M2 FOR SECURING DETAIL. ROOM SENSOR TO BE CONNECTED TO THERMOSTAT WIRELESSLY. 0 W 7B MECHANICAL CONTRACTOR IS TO INSTALL NEW WIRELESS ROOM SENSORS COMPATIBLE WITH HONEYWELL PRESTIGE WITH REDLINK THERMOSTAT. SENSOR IS TO BE WALL CL MOUNTED @ T-0"A.F.F.TO TOP OF SENSOR. SEE PLAN FOR GENERAL LOCATION. VERIFY FINAL LOCATION OF THERMOSTAT WITH HIBBETT SPORTS CONSTRUCTION a- Q DEPARTMENT PRIOR TO INSTALLATION. SEE DETAIL 5/M2 FOR SECURING DETAIL. ROOM SENSOR TO BE CONNECTED TO THERMOSTAT WIRELESSLY. Q0 W MENS WOMENS 8A MECHANICAL CONTRACTOR IS TO INSTALL NEW DUCT SENSOR(S)WITHIN SUPPLY DUCT PER MANUFACTURER'S RECOMMENDATIONS. DUCT SENSOR TO BE CONNECTED TO I'_ Q TLT ROOM TLT ROOM CORRECT EIM VIA 18/3 PLENUM SHIELDED STRANDED WIRE. W O 103 $g MECHANICAL CONTRACTOR IS TO INSTALL NEW DUCT SENSOR(S)WITHIN RETURN AIR DUCT PER MANUFACTURER'S RECOMMENDATIONS. DUCT SENSORS ARE TO BE 102 _ U O CONNECTED TO CORRECT EIM VIA 18/3 PLENUM SHIELDED STRANDED WIRE. �D } < OMECHANICAL CONTRACTOR IS TO INSTALL EQUIPMENT INTERFACE MODULE (EIM)FOR EACH HVAC UNIT. EIM IS TO BE MOUNTED JUST BELOW CEILING ABOVE r, Z MANAGERS/TRAINING AREA. INSTALL EACH EIM MINIMUM 48" FROM EACH OTHER. SEE PLAN FOR GENERAL LOCATION. VERIFY FINAL LOCATION OF RECEIVER WITH HIBBETT N O ®� 1 ® AA ❑ SPORTS CONSTRUCTION DEPARTMENT PRIOR TO INSTALLATION. EIM TO BE CONNECTED TO HVAC UNIT VIA 18/3 PLENUM SHIELDED STRANDED WIRE. wn �n uj m B B EX 10"0 S A. �___, 10 MECHANICAL CONTRACTOR IS TO INSTALL NEW 3-BUTTON OVERRIDE CONTROL IN STOCK AREA. SEE PLAN FOR GENERAL LOCATION.VERIFY FINAL LOCATION WITH ~ ¢ W N fX 6" S. F 12 ��� tRTS p° HIBBETT SPORTS CONSTRUCTION DEPARTMENT PRIOR TO INSTALLATION.CC EW 6 S. 8B S Lu 11 MECHANICAL CONTRACTOR IS TO INSTALL NEW EXHAUST FAN AND DUCT. UNIT SPECS ARE 6"0 DUCT SIZE, 1.7 AMPS, 100 CFM, 3.5 SONES, 115v/1 ph/60hz. ~ a 50 - ------ Uj U F ' i X 14"x12" A. t 11 B EXISTING EXHAUST FAN TO REMAIN. CLEAN AND REPAIR AS NEEDED. FQ-+ p �C o � NE iE 14'x12' S. 1 RTU-5 S t51 4 E ;, EE 4 t i �' 12 PROVIDE FIRE DAMPER WITH ACCESS PANEL IN NEW AND EXISTING DUCTS ABOVE CEILING. FIELD VERIFY. o N O t I i t — -- i� CORRIDOR 3 0 -- - BB - 13 NEW 2"THICK EXTERNALLY INSULATED (MIN. R-6.0) "LOW PRESSURE"SUPPLY AIR DUCT SUPPLIED'& INSTALLED BY MECHANICAL CONTRACTOR. PROVIDE TRANSITIONS AS 100 X 6"0 S. 12 ` EX 10"0 S.A. EX 16"0 R A. E 3 5 REQUIRED, DUCT DIMENSIONS ARE CLEAR INTERNAL AIR PATH DIMENSIONS. EXISTING DUCTWORK MAY BE CLEANED AND REUSED IF OF ADEQUATE SIZE.ALL DUCT WORK i 105 „ SHALL BE INSULATED AND ALL JOINTS, SEAMS AND CONNECTIONS IN DUCTWORK SHALL BE SECURELY FASTENED AND SEALED WITH WELDS, GASKETS, LISTED MASTICS, e. 7B F B qq 5 X 10"0 S.A .G `� OR LISTED TAPES, IN ACCORDANCE WITH IMC SECTION 603.9, 604,AND IECC SECTION 503.2.7 S 7 z z z O � z -i � w Z S RTU-4 14 MECHANICAL CONTRACTOR TO PROVIDE AND INSTALL NEW SUPPLY AIR DUCT SMOKE DETECTOR TO SHUT DOWN UNIT UPON DECTECTION OF SMOKE. EXISTING MAY BE z 0 ¢ w 0 a w S RE SED IF IN 00 WORKING ORDER. cq 0 w " w O 7777777, N W 10'x10" N W " RT z XXhm0 (D CO S 8'0 S.A 15 MECHANICAL CONTRACTOR TO REMOVE EXISTING 14"X14" DUCTBOARD BACK TO LOCATION SHOWN AND CAP AIRTIGHT. w w w w o o Z o w a A A 350 o _jZ � Wwm af= o N W 8" S.A. F w ¢ Lu Lu 0 U) FF-- Z z 8 J LULU = JJZ � O TU-4 EX1 "0 R. 10' 1 14 RT -3 7t EW1 "0 wQOUW � m UwU RT 3 Z (7 � Lu 8 SS - ' x 53 x ;,SS CONTRACTOR'S NOTES: w _° ~ w L A - � X 16' W 10" S.A. ��' O � cU) (D Z o 1= (D w Z Q jjD_D , - ALL OF THE MECHANICAL WORK IS NOT NECESSARILY SHOWN OR NOTED ON THESE DRAWINGS.THE CONTRACTORS SHALL VISIT THE JOB SITE AND VERIFY ALL EXISTING w p z J z m Z Z O Y O I .A. I U w O J _ U 1 _ N 10 �_ S TU-3 1 CONDITIONS RELATED TO THE WORK PRIOR TO BIDDING. THOSE ITEMS NOT SHOWN OR NOTED, BUT ARE DEEMED NECESSARY FOR REMOVAL OR RELOCATION BY THE OWNER OR w z w - U o 0 04 S U -4 A S. HIS REPRESENTATIVE, SHALL BE PART OF THIS CONTRACT.THE SUBMISSION OF THE PROPOSALS SHALL BE CONSIDERED AS EVIDENCE THAT THE CONTRACTORS HAVE VISITED I-- � Q co � U 0 m ¢ - � 13 m ��/ 1 14 300 A t 88 THE SITE.NO EXTRA PAYMENTS WILL BE ALLOWED, DUE TO EXTRA WORK MADE NECESSARY BY THE CONTRACTOR'S FAILURE TO VISIT THE JOB SITE. O twi m0 m ¢ w H- F- (7 = w z \ ` i 8B gg 36 300 N W 10 0 S. • MECHANICAL CONTRACTOR IS TO COORDINATE ALL WORK WITH OTHER TRADES INVOLVED. z u_ w o _O z U m ¢ NOTIFY HIBBETT SPORTS CONSTRUCTION DEPARTMENT (1-205-942-4292) PRIOR TO THE INSTALLATION OF THE ENERGY MANAGEMENT SYSTEM SENSOR(S). FAILURE TO CALL a H z O O w _ _ �- HIBBETT CONST. DEPT. PRIOR TO PLACEMENT, CAUSING RELOCATION, SHALL BE AT THE MECHANICAL CONTRACTORS EXPENSE. (n 0, m O Oz z w O D Z 0 O • DO NOT ATTACH ANYTHING TO UPPER LEVEL SLAB OR ROOF DECK. O m > z U) O Q F- 0 U) 0 F- z 7 50 PROVIDE SEISMIC BRACING AND RESTRAINTS FOR MECHANICAL EQUIPMENT AND DUCT WORK PIPING AS REQUIRED FOR STRUCTURES BUILT IN SEISMIC HAZARD GROUP B. O � ? 2 � 0 ¢ w U U is Y � MECHANICAL SYSTEM SUPPORTS SHALL BE DESIGNED AND INSTALLED FOR THE SEISMIC FORCES IN ACCORDANCE WITH THE BUILDING CODE. z 's o O 0 U p z p U S • HVAC CONTRACTOR TO ENSURE THERE IS ADEQUATE DISTRIBUTION OF AIR-CFM'S THROUGHOUT THEkENTIRE LEASED PREMISES. ~ O p T- F- F- d R � z (n (n (n z w I.- NIT-3 w _ LANDLORD IS RESPONSIBLE FOR HVAC ARCHITECTURAL SHOP DRAWINGS FOR THE ROOFTOP UNITS. U z o z m z 0 w 0 of cn w A SALES A EA • LANDLORD TO ENSURE ALL HVAC AND SPRINKLER SYSTEMS TO BE INSTALLED AROUND HIBBETT'S LIGHTING LAYOUT. SEE SHEET A-4 PRIOR TO INSTALLATION. _j � `( ¢ OU m j U w ZO 0 o A q ¢ O cn cq Q > U 0 5 325 100 350 MECHANICAL CONTRACTOR IS TO COORDINATE WITH ELECTRICAL CONTRACTOR FOR CONNECTION OF EQUIPMENT, THERMOSTAT(S),AND SENSOR(S)TO ENERGY MANAGEMENT � z U O O _ � 0 0 A W N W SYSTEM. CONTACT CHIP CUMMINS WITH CONTROL CO. @ 615-636-5767(CHIP@CONTROLCO.COM)WITH ANYQUESTIONS. Z Iw— p p o w F' Y F- C 20 0 .A. 80S. S. 10ls / _ 86 � 0 000001Qw wXw Rp 4 13 EW1 "0 N W1 '0 (� � Q UUU = cn � > � cnwa P.O. . i r SS.A. S. . STOCK AREA N " " HIBBETT ENERGY MANAGEMENT SYSTEM (EMS) ORDERING INFO: EX 1 x12 .A. i w NE 18' 12" A. NEW 2x1 "S.A. x 101 P.O.C.- EX 6"0 EW 1 "0 N W 10'0 ENERGY MANAGEMENT SYSTEM MUST BE ORDERED FROM CHIP CUMMINS WITH CONTROL CO._@ 615-636-5767 (CHIP@CONTROLCO.COM). ONE STAT MUST BE ORDERED PER UNIT. © COPYRIGHT 2014 W , R.A. A S HONEYWELL PRESTIGE WITH REDLINK THERMOSTATS USED WITHIN SYSTEM FOR HIBBETT SPORTS HAVE S�ECIFIC SETTINGS (74 A/C&68 HEAT)WHEN ORDERING. VERIFY THAT HIBBETT SPORTING GOODS, INC HIBBETT'S SETTINGS ARE PRESET ON STATS ORDERED. FAILURE TO DO SO WILL RESULT IN RE-INSTALLATION AT RESPONSIBLE PARTY'S EXPENSE.VERIFY THERMOSTATS ARE 3 2g 8" N 10 ' 1 14 1 TU - RAG 4 q ® COMPATIBLE EXISTING HVAC UNITS; OTHERWISE, PROVIDE& INSTALL INTERFACE EQUIPMENT AS NECESSARY. REVISIONS: S. EXIST. DU 35 1 BD COMMENTS FIELD VERI Y. ORDERING CONTACT: CHIP CUMMINS WITH CONTROL CO, INC. @ 615-636-5767(CHIP@CONTROLCO.COM) 1 8 SS A (TYP) q t8O WRr -S.A. Q 3 B i 01 o 7 MECHANICAL SPECIFICATIONS _ ROBERT L. QUEATHEM S RTU - A. IF BUILDING IS EQUIPPED WITH A FIRE SPRINKLER SYSTEM. REQUIRED ALTERATIONS TO THE SYSTEM RE TO BE DESIGNED AND INSTALLED BY A LICENSED SPRINKLER INSTALLER ENGINEER EW "0 NEW 4 AA B AA B AA 3 B ACCORDING TO CODE. PROVIDE APPROVED SPRINKLER DWGS.TO PROPERTY/OPERATIONS MGR. 2301s5o c AD,surra 30o sT.souls,neo 63146 PH.(314)415- 400 FAX(314)415- 0 www.ercv.com S.A. 8"0 S.A. B 2 2 B. HVAC REQUIREMENTS DURING CONSTRUCTION THE FOLLOWING IS REQUIRED BY HIBBETT SPORTING GOODS ON ALL HVAC PREVENTATIVE MAINTENANCE INSPECTIONS. THESE 8 R 4ITEMS MUST BE PERFORMED AND CHECKED OFF, NOTING ANY PERTINENT INFORMATION. (i.e., OPERATING PRESSURES, ETC.) l i > > t o i, 1. REPLACE DISPOSABLE FILTERS OR CLEAN PERMANENT TYPE FILTERS. RT SS 2. LUBRICATE ALL BEARINGS, PUMPS, FANS AND MOTORS AS NEEDED. ,�.,�;?: X 8„ 3. INSPECT FOR LEAKS ON EQUIPMENT AND PIPING. f a =`= B 15 .�� 4B '�'' ( P) 4. CLEAN AND CHECK CONTROLS ON THERMOSTAT. 5. ADJUST FOR PROPER TENSION ON ALL BELTS AND PULLEYS. X 14” 14"S A. I t- i EX 1 "x`14"S.A. 6. INSPECT ALL ELECTRICAL COMPONENTS AND TIGHTEN AS NECESSARY. X 8"0 8B7. CHECK OPERATION PRESSURES OF COMPRESSORS AND OIL LEVEL IN CRANK CASE. __________________ B I EX 6" 8. CLEAN OUT CONDENSATION DRAIN PANS AND LINES. I r- , 3 20 A. (T RTU-1 RTU RTU RTU RTU RTU 9 '--- R.A. 9. ANY NORMAL INSPECTION SERVICE REQUIRED FOR THE UNIT. T T T T T 0 I _ R U - 1 4B D 10. LIST EQUIPMENT INFORMATION BELOW: 'oi +_ - ', u w 12 1 14 I T '' frrttw� I F C. FIRE EXTINGUISHERS: REFER TO SCHEDULE OF RESPONSIBILITIES (SHEET T1)TO VERIFY THE PARTY RESPONSIBLE FOR INSTALLING FIRE EXTINGUISHERS. THE SAME 9 1 RESPONSIBLE PARTY WILL BE REQUIRED TO HAVE THE FIRE EXTINGUISHERS LABELED WITH THE PROPER STATES INSPECTION TAG 5 6 10 j L------------------- 1z w B 3 AA g B AA AA B 150142 0 10 If \1 7B B 5 3 7 MECHANICAL PLAN &DETAILS FZT -5 RT -4 RT -3 IM EIM EIM S RTU 1 LOCATION: # 1294 O FT DATE: FEBRUARY 2015 FITTING SHEET ROOM 1 HVAC PLAN 104 1�_iSCALE: 3/16" = V-0" v 5. s I I ZI OI al F-I Q O >I Lu 4.1 � w SUPPLY AIR DUCT,INSTALL SPIN-IN TAP FITTING SUPPLY SENSOR AS 4'-0" MIN SEPARATION 4'-0" MIN, SEPARATION 4'-0" MIN SEPARATION 4'-0" MIN SEPARATION W/AIR SCOOP& INDICATED ON PLAN FINISHED CEILING Q r 1 DAMPER. L---- '----,� ----}"��, I L----}-`'�--_ L---- �'� L---- � EXISTING HVAC ROOFTOP UNIT SCHEDULE _ rn - O.A. ELECTRICAL `��_ i '� Lu MARK MANU. MODEL NO. COOLING CAPACITY SEER HEATING CAPACITY CFM CFM TONNAGE INSULATED FLEX / EQUIPMENT INTERFACE VOLTS Hz PHASE DUCT MODULES(EIM)MOUNTED ON WALL ABOVE JUST BELOW ��'�.,,, - ` > c RTU-1 CARRIER 50G5-60--501 60,000 BTU 10.0 *11.3 KW 2000 260 5 TON 208/230 60 3 --INSULATE SPIN-IN TAP CEILING AT MANAGERS AFTER TEST AND BALANCE. TRAINING AREA. PROVIDE `� �-., ` \ r , Z r , SQUARE TO ROUND POWER TO THERMOSTAT RTU-2 CARRIER 50SS-60---521 59,500 BTU 10.0 *11.3 KW 2000 260 5 TON 208/230 60 3 NYLON DRAW BAND FROM PAIRED EIM. 42 MBH @47°F ADAPTER RTU-3 CARRIER 50HX-048--301 46,000 BTU 12.0 1600 260 4 TON 208/230 60 1 &3.4 COP INSULATE TOP OF RTU-4 CARRIER 50SS-048--521 47,000 BTU 10.0 * 170 4 TON 208/230 60 3 DIFFUSER 11.3 KW 1600 48 MBH @47°F ® SUSPENDED CEILING TILE I RTU-5 TRANE WCC048F300BG 48,000 BTU 10.0 1600 260 4 TON 208/230 60 3 &3.4 COP SQUARE OR -24"X24"LAY-IN DROP TYPE NOTES: PANEL TO MATCH CEILING I i 1 i I ALL UNITS ARE EXISTING TO REMAIN.SEE KEYED NOTE 1/M-1. UNITS 3 AND 5 ARE HEAT PUMPS WITH NO ELECTRIC HEAT. RECTANGULAR *VERIFY HEATING CAPACITY IN FIELD CEILING DIFFUSER W/ � \� SEE PLANS FOR TILE. DO NOT SUPPORT CEILING DIFFUSER BY THROW INDICATION BALANCING DAMPER. I Q Q M CEILING TILE. IF 4 I L__J L__J PRESTIGE NEW EXHAUST FAN SCHEDULE TYPICAL LAY-IN DIFFUSER DETAIL THERMOSTATS M-2 SCALE: 1 - 1 -0 i L WIRELESSLY ' MARK I CONNECT TO TOTAL TSP MAX DRIVE FAN CONTROL MOTOR MAX FAN REMARKS I ____ OVERRIDE RIG SEE 1/E4 W MARK CFM IN WC RPM TYPE TYPE WITH HP/AMPS SONES SERVICE VOLTS Hz PHASE i CONTROL FOR DETAILS > CLG OCCUP. I W ~ EF-1 110 .125 - DIRECT 1.3 AMPS 4.0 120 60 1 TOILET EXH BASIS OF DESIGN:BROAN#676 ®® ©© I ao oa ©o o® __J Q Z 00 W MOUNT SENSOR I �r 3 BRAIDED STEEL WIRE,TUCK EXCESS BEHIND SLAT i REDLINK INTERNET FORTINET ROUTER GATEWAY (RIG)AT 0C Q OUTSIDE AIR SCHEDULE ce WIRE CRIMP SLEEVE i (PROVIDED BY OTHERS) MANAGER'S DESK ¢` w LOOP WIRE THROUGH VENT i CONNECT TO PORT 5 AT LU 0 DESCRIPTION AREA AREA AREA OCCUPANT OCCUPANCY OCCUPANT OCCUPANT BREATHING ZONE AIR ZONE HOLES C N TOP OF SENSOR AND i FORTINET ROUTER ZO (SQ. FT.) OUTDOOR OUTDOOR LOAD RATE C x F/1000 OUTDOOR OUTDOOR ZONE DISTRIBUTION OUTDOOR SENSOR BRACKET I (PROVIDED BY OTHERS) W AIR RATE AIR PER FMC (Pz) AIR RATE AIR OUTDOOR EFFECTIVENESS AIR _ + iJ b PER FMC (RaAz) TABLE PER FMC (RpPz) AIR (Ez) (Voz SENSOR MOUNTING BRACKET FINISHED FLOOR _ � TABLE 403.3 TABLE (Vbz=RpPz Vbz/Ez) w 0 P Q MOUNTED TO SLATWALL AS : m 90 INDICATED ON A2.2AND M1 1 HVAC EQUIPEMENT MOUNTING DETAIL ,� z 403.3 (PEOPLE/1000 403.3 +RaAz) W RELESS ROOMSENSOR ¢ �-2SCALE: 1/2" - 1'-0" N o (RA) SQ.FT.) (Rp) m - Lu W M V SALES FITTING 3480 0.12 417.6 15 52.2 7.5 391.5 809.1 0.8 1011.4 NETWORK POD"3" J N STOCK 1079 0.12 129.5 0.0 0.0 129.5 0.8 161.9 HALL/TOILET 269 0.06 16.1 0.0 0.0 16.1 0.8 20.2 OV Q M Z 1193.4TOTALS 4828 Nd- WIRELESS ROOM SENSOR . RIG WIR7Honeyw.11 Z Q Lr) 5 SECURING MOUNTING DETAIL I-- o TOTAL 0UTSIDE AIR CFM PROVIDED BY ALL UNITS 1210 M-2 SCALE: 6" = 1'-0" ¢ Z CALCULATIONS BASED ON 2010 FMC THERMOSTAT SUBBASE a' N m U U MOUNT ON WALL ~ THERMOSTAT zs POWER SUPPLY 120VAC POWER C C-® Z ZZO � Z -r � WZ R R-0 REDLINK INTERNET SUPPLY uj C7 C7 ILW >_ p W W GATEWAY(RIG} O Q W O (L W W2 O UmOLu WILL Ix � W3® W WWI- m0 (9 maW Z LLZ Q _ G2 0 ¢ Z A eW � m QF' 0 coU H 2 W W Wo � O WF- Z U2 ® eW2 U FtZ ~ UQ � m 05 3: U1 � Y2 m m0OWW > z O Z W U1 ® aG > W 4 F- H RHO , R O F- U) QZ � � UWZ O RC C U W � =OZJZOm ZzoY R W Z F= � � W - U = dpi U � ®C2 3: E D C DISCHARGE AIR �-- m Q w O O m Q H S4 S2 SENSOR(MOUNT ON W m CO < WW Z F- C7 F- } S4 S2 DUCT)18-2(SH ELDED) HVAC UNIT TERMINAL O W O D a W ~ Z = m O S3 S1 STRIP @RTU z W � Z 5 a W X O-Q-t 0 =1 LL ® rr^^ too OWm 2r = O RETURN AIR SENSOR v! O Cn j Z m ZO w O w Z O z (MOUNT ON DUCT} _ (7 W Z Z O W O W 18-2(SHIELDED) U) Z F- U Q W U U F- Y EQUIPMENT INTERFACE Honeywell O Z m - 2 U O W MODULE(EIM) ��� 09 m 2: U Z PRESTIGE WIRING DIAGRAM 1 Z [[QLL m Z Z Q Ip W 0 V WW LQQOm ? OU Uz02 O � U O F3 (uj f- Zz Zdm p ZU WIRELESS TEMP Z m U O O W - W o ILL O O I- W F- 1-- SENSORS z WO ~ ~ ~ � `1LL � F- � 2 HVAC WIRING DIAGRAM Q - Z zzzmmo � ° QWo �-2SCALE: NTS V foo OOOTD W Wu<_ Xof HVAC RTU © COPYRIGHT 2014 HIBBETT SPORTING GOODS, INC I` REVISIONS: RETURN AIR SENSOR EQUIPMENTIINTERFACE MODULE (EIM) SUPPLY AIR CONNECTIONS KEY 1 SENSOR I ROBERT L. OUEATHEM HARDWIRE W j ENGINEER CONNECTIONO ,? 1850 CRAIG ROAD,SUITE 300 ST.LOUIS,MO 83146 CL I PH.(314 415-2400 FAX(314)415-2300 www.ercv.com I �;iiS6t� t WIRELESS I , C\ CONNECTION PRESTIGE WIRELESS `''' THERMOSTAT ROOM SENSOR `' !GATEWAY DLINK INTERNET WIRELE(RIG) - OVERRIDEoe 150142 NETWORK HVAC SCHEDULES&DETAILS POD 113" LOCATION: # 1294 HVAC EQUIPMENT DATE: FEBRUARY 2015 3 CONNECTION DIAGRAM SHEET �-2SCALE: NTS M �2 LINE UNIT NTED ABOVE CEI ING.E EE DETAILU5/E1.°" PLATFORM POWER KEYED NOTES REFER TO RESPONSIBILITY OF WORK ON SHEET T1. (DEDICATED=CIRCUIT TO HAVE ISOLATED POWER AND GROUND) BRING CIRCUIT WI ING FROM PANEL TO J-BOX. , I LOOP CONNECTION THROUGH LINE CONDITIONER 1A ONE 20 AMP SIGN CIRCUIT REQUIRED. INSTALL DISCONNECT SWITCH AS O AND CONNECT THROUGH 3/4" PVC CONDUIT 4 SUPPLY AND INSTALL THE FOLLOWING SERVICE BELL EQUIP (SEE DETAIL 5/E1: ® U. DOWN THROUGH FLOOR SLAB AS SHOWN HERE. REQUIRED BY N.E.C. 600. ALL SIGNAGE TO BE INSTALLED BY SIGN CONTRACTOR. a) EDWARD'S #88-50 TRANSFORMER MTD ABOVE FINISHED CEILING AT W FINISHED CEILING FIELD COORDINATE EXACT LOCATION. ALL SIGNS TO BE 120V. MAKE FINAL CORRIDOR DOOR, CORRIDOR SIDE. -� NOTE: CONNECT POWER TO CONNECTION AFTER SIGN INSTALLED BY OTHERS. b) EDWARD'S #340-4G5 BELL MOUNTED 2" ABOVE DOOR FRAME, ATrn SENSORMATIC PEDESTALS AND I I SIGN CIRCUIT TO BE ON A DEDICATED, LOCKED-OUT CIRCUIT. SALES/CORRIDOR DOOR. BELL TO BE OPERATED BY BOTH FRONT AND REAR V INTER-CONNECT CABLE AFTER 8'-2- INSTALLATION BY OTHERS. 1 B SIGN CIRCUIT IS TO BE CONNECTED TO HIBBETT E.M.S. VERIFY EXACT LOCATION PUSHBUTTONS. SEE DETAIL 5/E1. CONTACT HIBBETT CONSTRUCTION I I O co v DEPARTMENT FOR SCHEDULING. I I OF E.M.S. WITH HIBBETT SPORTS CONSTRUCTION DEPARTMENT. SEE DETAIL 7/E4 5A & 8/E4. PULL ALL ELECTRICAL RECEPTACLES IN SALES AREA AWAY FROM THE WALL AND J Q 1 I INSTALL FOR SLAT WALL INSTALLATION. INSTALL NEW RECEPTACLES AS SHOWN 7,_10„ ; I IINSTALL 3/4" PVC CONDUIT BELOW SLAB, SIGN CIRCUIT & E.M.S. TO BE ON A DEDICATED, LOCKED-OUT CIRCUIT. SIGN J WTHIN TRENCH AREA AS SHOWN. CONDUIT I ( CIRCUIT TO BE LABELED "STOREFRONT SIGN" ON PLAN AT 15 A.F.F. SEE DETAIL 4A/E1. s -��� i WCONTAIN PULL STRING FOR SENSORMATIC I I OUTLETS & COVERS TO BE IVORY. CIRCUITS ARE TO BE LABELED RECEPTACLE DIMENSIONS FOR SLAB TRENCH CUT INSTALL 90' CONNECTOR TO FIRST PEDESTAL PEDESTAL. I - GENERAL SALES AREA" LOCATION FROM FIRST CONDUIT CONTAINING f ( 2A PROVIDE ONE 3/4" RIGID CONDUIT & IG QUAD RECEPTACLE FOR DEDICATED CIRCUIT WIRING. ; ; J-BOX W/ WIRING MOUNTED ABOVE CEILING. I INSTALL 90' CONNECTOR FROM P.O.S. CIRCUIT. CIRCUIT USED TO POWER THE ELECTRONIC CASH REGISTER 11 RUN 3/4" PVC CONDUIT THROUGH DISPLAY I CONDUIT TO SECOND PEDESTAL I SHALL NOT BE USED FOR ANY OTHER PURPOSE AND SHALL NOT SHARE 5C PULL ELECTRICAL RECEPTACLES ON SALES AREA COLUMNS AWAY FROM WALL U U WALL AND CONNECT TO 3/4" PVC CONDUIT LOCATION. I NEUTRAL OR GROUND WITH OTHER EQUIPMENT. SEPARATE POWER NEUTRAL AND AND INSTALL FOR SLAT WALL INSTALLATION. INSTALL NEW RECEPTACLES AS UNDER SLAB VIA 90' ELBOW CONNECTION. I SHOWN ON PLAN AT 15" A.F.F. SEE DETAIL 4C/E1. FINI HED FLOOR R INSULATED GROUND WIRES, MINIMUM SIZE #12 AWG, SHALL BE RUN TO THE OUTLETS & COVERS TO BE IVORY. CIRCUITS ARE TO BE LABELED "RECEPTACLE SENSORMATIC TRENCH-CUT CIRCUIT BREAKER PANEL BOARD WHERE GROUND WIRE SHALL BE TIED TO THE - GENERAL SALES AREA" Z Z GROUND TERMINAL. DO NOT USE CONDUIT FOR GROUNDING AS THIS IS NOT INSTALL 3/4" PVC CONDUIT BELOW INSTALL 90' CONNECTOR FROM CONDUIT ADEQUATE AT HIGH FREQUENCIES. RECEPTACLES SHALL BE HUBBELL IG-5362. MM Q SHOWN. COINDUIT TOHCO AIN CIRCUIT AREA AS TO THIRD PEDESTAL LOCATION. ROUTE CONDUIT DOWN WALL AND UNDERNEATH SLAB AS SHOWN ON PLANS AND 6A RECEPTACLE(S) FLUSH MOUNTED IN CEILING PER N.E.C. 210-62. RECEPTACLE(S) Q 2 CJS CONDUIT DETAIL FOR SENSORMATIC PEDESTALS. INSTALL ADDITIONAL 90' ELBOW CONNECTOR AND PATCH FLOOR AS REQUIRED. VERIFY LOCATION WITH OWNER PRIOR TO & COVER(S) TO BE PEARL WHITE. IF SOFFIT EXISTS, INSTALL RECEPTACLE(S) ON 1 j E-1 SCALE: 1/4"=V-0" INSTALL 90' CONNECTORS TO FIRST 3/4" C CONDUIT FROM PEDESTAL LOCATION ROUGH-IN. REFER TO CASH WRAP DETAIL 1/E4 AND CASH WRAP ELEVATION UNDERSIDE OF SOFFIT. CONTACT HIBBETT CONSTRUCTION DEPARTMENT PRIOR TO ` V PEDESTAL LOCATION. TO PED STAL LOCATION. INSTALL PULL STRING 2/E4. INSTALLATION TO VERIFY LOCATION. INSIDE CONDUIT FOR INTER-CONNECT CABLE. P.O.S. TO BE ON A DEDICATED, LOCKED-OUT CIRCUIT. P.O.S. CIRCUITS TO BE CIRCUIT IS TO BE LABELED "RECEPTACLE - STOREFRONT SOFFIT" vTJ CVV 3 S E N S O RMAT I C E L E AT I O N DETAIL LABELED "RECEPTACLES - CASH & WRAP (P.O.S.)" 66 RECEPTACLE FLUSH MOUNTED IN CEILING. OUTLET & COVER TO BE PEARL WHITE E-1 E: 1 4"=1'-0" 2B PROVIDE ONE 1" RIGID CONDUIT & TELEPHONE DATA OUTLET NETWORK POD "A"). O RECEPTACLE(S) TO BE ON A DEDICATED LOCKED-OUT CIRCUIT. CIRCUIT IS TO BE SCAL / O ROUTE CONDUIT DOWN WALL AND UNDERNEATH SLAB AS SHOWN ON PLANS ANLABELED "RECEPTACLE - CEILING 15' FROM DOOR" PATCH FLOOR AS REQUIRED. VERIFY LOCATION WITH OWNER PRIOR TO 7 DUPLEX RECEPTACLE(S) MOUNTED 13'-0" A.F.F. FOR SECURITY EQUIPMENT (3 ROUGH-IN. REFER TO CASH WRAP DETAIL 1/E4 AND CASH WRAP ELEVATION LOCATIONS UNLESS OTHERWISE NOTED). OUTLETS & COVERS TO BE IVORY. 2/E4. SECURITY RECEPTACLES TO BE ON A DEDICATED LOCKED-OUT CIRCUIT. CIRCUIT W OPROVIDE ONE 3 4" RIGID CONDUIT WITH TWO 2 PULL STRINGS FOR IS TO BE LABELED - "RECEPTACLES OVERHEAD SECURITY" p 2C F- SECURITY/MUSIC. ROUTE CONDUIT DOWN WALL AND UNDERNEATH SLAB AS " ad Ir U-' MENS WOMENS 200-8#9 SHOWN ON PLANS AND PATCH FLOOR AS REQUIREDVERIFY LOCATION WITH O TWO QUAD RECEPTACLES MOUNTED AT 36 A.F.F. TO TOP OF BOX AT TRAINING . a FIN. CEILING I- TLT ROOM TLT ROOM ,1 A-14 2A 2C 2B 2'-0' N BUZZER TRANSFORMER OWNER PRIOR TO ROUGH-IN. REFER TO CASH WRAP DETAIL 1/E4 AND CASH AREA. VERIFY LOCATION WITH HIBBETT CONSTRUCTION DEPARTMENT PRIOR TO Q 9 2#14, 1#14 OND, 1/2 WRAP ELEVATION 2/E4. ROUGH IN. SEE DETAIL 3/E4. < a. 103 D�] 5A A-8 2D 2D A-16 5A OUTLETS & COVERS TO BE IVORY. RECEPTACLES TO BE ON A LOCKED OUT0 w BELL F-CIRCUIT. CIRCUIT IS TO BE LABELED - "RECEPTACLES TRAINING" 2D PROVIDE ONE 3/4" RIGID CONDUIT & IG DUPLEX RECEPTACLE FOR DEDICATED 1-- z �jj ��:� J l 111 CIRCUIT. THE CIRCUIT USED TO POWER RECEPTACLE SHALL NOT BE USED FOR W O 4 _ 3 4 4 111 4 3 4 4 ANY OTHER PURPOSE AND SHALL NOT SHARE NEUTRAL OR GROUND WITH OTHER O TWO DUPLEX RECEPTACLES & TWO TELEPHONE/DATA OUTLETS (NETWORK PODcn ,14 i 3 i i ii 7 i EQUIPMENT. SEPARATE POWER, NEUTRAL, AND INSULATED GROUND WIRES, "B" & "C") @MANAGER'S AREA TO BE MOUNTED AT 36" A.F.F. TO TOP OF v WP WP • A-20 `` O I I ii SALES/CORRIDOR DOOR MINIMUM SIZE #12 AWG, SHALL BE RUN TO THE CIRCUIT BREAKER PANEL BOX. VERIFY LOCATION W/ HIBBETT CONSTRUCTION DEPARTMENT PRIOR TO F_ GFI GFI A-36 `� A-34 ao Z i i i t i I BOARD WHERE GROUND WIRE SHALL BE TIED TO THE GROUND TERMINAL. ROUGH-IN. SEE DETAIL 3/E4. A-10 i RECEPTACLE SHALL BE HUBBELL #IG-5362. ROUTE CONDUIT DOWN WALL AND OUTLETS & COVERS TO BE IVORY. RECEPTACLES ARE TO BE ON A DEDICATED, z C° o iIt i UNDERNEATH SLAB AS SHOWN ON PLANS AND PATCH FLOOR AS REQUIRED. LOCKED-OUT CIRCUIT. CIRCUIT IS TO BE LABELED "RECEPTACLES - MANAGER" p N O 12 �\ ; ] i VERIFY LOCATION WITH OWNER PRIOR TO ROUGH-IN. REFER TO CASH WRAP ui lti c`i A-30 �� 17 IG IG IG DETAIL 1/E4 AND CASH WRAP ELEVATION 2/E4. 10 TRENCH SLAB CONTAINING 3/4" PVC CONDUIT & CIRCUIT FOR SENSORMATIC I -� w rn • 1 �`\ C-1,3,5 RECEPTACLE TO BE ON A DEDICATED, LOCKED-OUT CIRCUIT. CIRCUIT TO BE PEDESTAL(S). 0 Ov ¢ m � 7ZA \ RTU-5 L4' 0 4 -0 18 1LABELED RECEPTACLE - CASH & WRAP SENSORMATIC SYSTEM IS TO BE ON DEDICATED, LOCKED-OUT CIRCUITS. CIRCUITS W <• „ , „ ,_ „ FIN. FLOOR ARE TO BE LABELED "SENSORMATIC SYSTEM" co i ¢ _ rn CORRIDOR O3 SUPPLY AND INSTALL THE FOLLOWING SERVICE BELL EQUIP: LLI (D Q n ��� a) EDWARD'S 24V #852 PUSH-BUTTON MOUNTED AT 60" A.F.F. AT REAR 11 J-BOX WITH WIRING MOUNTED ABOVE CEILING. RUN 3/4" PVC CONDUIT o 5 BELL ELEVATION b) EDWARD'S 24V #852 PUSH-BUTTON MOUNTED AT 60" A.F.F. OUTSIDE THROUGH DISPLAY WALL AND CONNECT TO J" PVC CONDUIT UNDER SLAB VIA 90' <C' o p - 105 `�� / OF FRONT ENTRY. (INSTALL ON OUTSIDE FACE OF MULLION "NO BOX") ELBOW CONNECTION. RUN PULL STRING TO FIRST PEDESTAL LOCATION. SEE cv m v @J E-1 SCALE: 6"=1'-0" BELL EQUIPMENT CIRCUIT IS TO BE ON A DEDICATED, LOCKED-OUT CIRCUIT. DETAILS 2/E1 & 3/E1 FOR DETAILS. 1X4 ' ',``_�5C � CIRCUIT IS TO BE LABELED "DOOR BUZZER'. SENSORMATIC SYSTEM IS TO BE ON A DEDICATED, LOCKED-OUT CIRCUIT. ---3 4- - - - - -,; ---- -�_ 4 i - CIRCUIT IS TO BE LABELED "SENSORMATIC SYSTEM" ------------------------------------------------- --------------------- -------------------------------------------------- ----------------------------------------------------------------------------------- C-7,9,11 C-13,15 ��\ 12 NON-FUSED DISCONNECT SWITCH MOUNTED ABOVE TOILET CEILING FOR STOCK AREA ' A-34 �- _ � i CONNECTION OF HOT WATER HEATER. CD cD 11• w � ❑ w � r- A-34 `� / WATER HEATER CONNECTION TO BE ON A DEDICATED CIRCUIT. CIRCUIT TO BE z z z o 0 z -g w z 101 � � � LL O O_ w r7� �� i LABELED "WATER HEATER". o o w " w � x x �� i z wwI- mOo M0- 17 17 RTU-3 ` 13 FIELD VERIFY EXACT LOCATION OF TELEPHONE SERVICE. EXTEND AND CONNECT ''' w ❑ ❑ w ❑ w a AS REQUIRED FOR CONNECTION TO NEW TELEPHONE EQUIPMENT. PROVIDE 4' X o J Z w m ¢ o RTU 4 a a _ � v ;' �* 8' X 3/4" PLYWOOD BACKBOARD FOR MOUNTING OF ELECTRICAL AND o w w E O o I=- z Off TELEPHONE EQUIPMENT. SIZE AND SECURE AS REQUIRED. PROVIDE TWO DUPLEX Q � a z o w O x x x x x v ❑ I RECEPTACLES FOR POWER TO EQUIPMENT & TWO TELEPHONE/DATA OUTLETS w a o U w m v w v PANEL "C" 15 I 16 V) _j x �.'� (NETWORK PODS "2" & "4") @ TELEPHONE BACKBOARD. OUTLET AND COVER TO w ~ ❑ m O z x w � rj w w ,� BE IVORY. SEE TELEPHONE BACKBOARD ELEVATION 4/E4. > O v = Q O o n c~n ��t � z p DUPLEX RECEPTACLE (S) TO BE ON A DEDICATED, LOCKED-OUT CIRCUIT. ~ o Z) I- J z 2i z o x x x x O - �� " " w Oz _ Om pZU1 I- _ CIRCUIT IS TO BE LABELED RECEPTACLE - TELEPHONE BOARD v � of w - 0 ❑ Tx x � _ z i - 6i z W } m2 � U) > r ELECTRICAL SPECIFICATIONS w z mQ � �'' 5C /' `' 14 E.C. SHALL INSTALL HIBBETT LIGHTING CONTACTOR ("EMS-2") PANEL PROCURED O w m Q m Q x z o O >_ } FROM CONTROLCO, INC. (CONTACT CHIP CUMMINS @ 615-636-5767) THIS w o ❑ °- o U) X z czi M z ------------ - z ---------------- ---- ------------------------ --- -- ------------ ------------------------------ ---- -- ------- -------------------- ELECTRICAL cn w - _ ------- --- -------------------- ----------- ----------- -------------tzt- -------------------- ------------------------------ - ---------------------------------------------------------------------------- ------ -- PANEL CONTAINS: AEG MODEL LS7K-04-G - AEG FOUR-POLE, N.C., 30A z a 1- z ❑ ❑ O w � 5 _ _ LL ------- --- ----- .- w Lam. O �� LIGHTING CONTACTOR, 24 VAC COIL TO CONTROL THE FOLLOWING: (/) ❑ - o O a ❑ O x x D_ A. REFER TO ELECTRICAL PLANS FOR POWER KEYED NOTES AND PLACEMENT OF ALL ELECTRICAL z w o p 1- N o ¢ �� DEVICES AND EQUIPMENT. REFER TO T1 FOR RESPONSIBILITY SCHEDULE. a) CONTACTOR TO CONTROL SALES FLOOR LIGHT FIXTURES ONLY O z > Z m Q w O o Yuj z �� B. SIGNAGE HOOKUP(S) AND CONTACTOR CONNECTIONS ARE NEW. E.C. TO PROVIDE ADDITIONAL b) CONTACTOR TO CONTROL STOCK ROOM & CORRIDOR LIGHT FIXTURES O _ � ~ b aQz e-9,11,13 SALES AREA o LY z � � ooX0o < af5oM CIRCUITS AS REQUIRED. ALSO REFER TO E1 FOR PLACEMENT AND T1 FOR RESPONSIBILITY x x x x x z_ Q SCHEDULE. c) CONTACTOR TO CONTROL TRACK LIGHTING FIXTURES ONLY ❑ w c i vi ❑ Z a- w w r 1-00 1OO 6A (CEILING MTD * (.) ❑ z ❑ w z w I o A-34 A-24 ) C. FOR PLACEMENT OF NEW LIGHT FIXTURES, REFER TO SHEET A4, REFLECTIVE CEILING PLAN. ALSO W� LL CONTACTORS SHALL BE NORMALLY CLOSED TO PREVENT LIGHT LOSS ¢ z x x z cn `� z - o N � N Q j1 REFER TO T1 FOR RESPONSIBILITY SCHEDULE. DURING OCCUPIED TIMES IN THE EVENT A CONTROLLER WITHIN THE EMS FAILS. Q p 0 d } O p D r 1 D. CONTACT STEVE BENTRUP OF CITY LIGHTING PRODUCTS @ 800-888-2572 FOR ORDERING INFO. E.0 TO PROVIDE AND INSTALL CONTACTOR ENCLOSURE AND 3/4" GLAV. o 0 1-- z z z w CO ❑ w z U t 't V) I CO DUIT FOR CONNECTION FROM CONTACTOR ENCLOSURE TO E.M.S. SYSTEM. ~ w ,� C) o0 o � o O w - o i E. MOTION SENSORS ARE TO BE CONNECTED TO RESTROOM FITTING ROOM FIXTURES PER SHEET E2 z - - x x x x ¢ I- 17 RTU-2 i DIRECTION. / LABEL ALL CONTACTORS ACCORDINGLY. SEE TELEPHONE BACKBOARD ELEV. 4/E4. zo z z z m o v o mv I F. CONNECT ALL CONTACTORS TOE.M.S. ALL CONTACTORS S LL L CLO m 00 O Lu w a EE I A HIBBETT E.M.SHA BE NORMALLY SED TO 000 _ O w � w x x 0 _ 0 o '._ i 15'-0" O.C. DOOR A.F.C. PREVENT LIGHT LOSS DURING OCCUPED TIMES IN THE EVENT A CONTROLLER WITHIN THE E.M.S. 15 INSTALL TYPEWRITTEN DIRECTORY IN DOOR OF EACH PANEL. CIRCUITS SHALL BE U ❑ v o = m W a w (n I A-22 I 20A FAILES. CONNECT TO EMS SYSTEM VIA 3/4" GALVANIZED CONDUIT TO CONNECT CONTACTOR NUtABERED ALTERNATELY (I.E. 1,3,5 AND 2,4,6). x x x x x cv Q 36 N F 1A 1 B ENCLOSURE TO EMS SYSTEM PANEL BOX. LABEL CIRCUITS PER POWER KEYED NOTES. 1 PANEL "B" 16 15 w go 6B it G. TELEPHONE 16 SU_F FACE-MOUNTED ELECTRICAL PANEL. © COPYRIGHT 2014 w I CEILING MTD 1 A-1 HIBBETT SPORTING GOODS, INC �r o: i ( ) ; 0 1. HIBBETT SPORTS WILL HAVE LOCAL PHONE COMPANY INSTALL SERVICE TO TELEPHONE BACKBOARD 17 WEATHERPROOF G.F.C.I. RECEPTACLE BY E.C. TO BE INSTALLED PER N.E.C. x x x x x Q AT REAR OF SPACE. 210-63. REVISIONS: 10 `t 2. TELEPHONE SERVICE WITHIN THE LEASED SPACE To BE WIRED FOR A TWO LINE DATA SYSTEM x ' \ (LOCATIONS ON POWER PLAN.) 1 BD COMMENTS 04/02/15 N 5C 3. CONTRACTOR IS RESPONSIBLE FOR RUNNING CAT-5e WIRE To EACH JACK AS PER POWER PLAN. _ -__ _�r_ ---------- ----------- ----------------- --- ------------------------------------____ ¢ -----------------_------------------------ -------------------------------- ------ -------------- ---- 6A (CEILING MTD) 4. CONTRACTOR IS RESPONSIBLE FOR MAKING FINAL CONNECTION ATTELEPHONE B C ------------------ - M A BACKBOARD. ---------- ----------------------------------------------------------------- --------------------- 11 5. CONTRACTOR IS RESPONSIBLE FOR MAKING THE PHONE/DATA JACK WORK AFTER THE LOCAL x PHONE COMPANY INSTALLS SERVICE To TELEPHONE BACKBOARD AT REAR OF SPACE. N , -'' A-2,4,6 A -18 H. SIGNAGE ROBERT L. OUEATHEM x x x x � 1. STOREFRONT SIGN IS DESIGNED FOR 120v SERVICE, ONE 20 AMP CIRCUIT REQUIRED UNLESS ENGINEER 3A ; A-34 OTHERWISE NOTED. SW CRAIG ROAD,SURE 300 ST.LOUIS,MO M46 A-12 10 2. CONTRACTOR IS RESPONSIBLE FOR MAKING ELECTRICAL CONNECTIONS TO STOREFRONT SIGNAGE PR(39)415-2400 FAX(314)415-2300 www.arcv.can --- ; AFTER SIGN INSTALLATION BY OTHER. (SEE RESPONSIBILITY SCHEDULE) 7 4 ; 17 TR U_1 3. CONTRACTOR IS RESPONSIBLE TO HAVE ALL STOREFRONT LIT SIGNAGE CONNECTED TO HIBBETT SPORTS ENERGY MANAGEMENT SYSTEM VIA LIGHTING CONTACTOR. A-10 'x. "- 4. CONTRACTOR IS TO PROVIDE ACCESS PANEL(S) FOR SIGNS) 36" X 36" UNLESS OTHERWISE , ly i NOTED. ;. �.• ;-� i 5. CONTRACTOR IS TO PROVIDE ADEQUATE STRUCTURAL SUPPORT FOR TECHNICIANS TO SERVICE .' • ° =M „ „ 15 � / SIGNAGE. ,..�• �. PANEL A 16 A-12 � � ��. z � t� •�«- 14 i I ETAL STUDS :�+° 4 .r TELEPHONE-,, 16 --- --------------,-, _,-METAL STUDS w A-26 0 - - BACKBOARD I 8 ,-- - CONTRACTOR'S NOTES: SUM BOARD WALL 1::cypsum BOARD WALL •^ RE: 4/E4 io i _ I ,,_ --------- _ ' 13 �\ A-28 i !HEE NEEDS TO BE 1 UNDER NO CIRCUMSTANCES ARE THERE TO BE LIGHT SWITCHES INSTALLED IN THE SPACE. TOERFACE OF THE GYPSUM 2BOARD TO BETWEEN THE THERFACEEDS OF THE GYPSTO BE UM BOARD TO THE O �' � CONSEQUENCES WILL INCLUDE RE-INSTALLATION AT ELECTRICAL CONTRACTOR'S EXPENSE. F�CE OF THE DUPLEX OUTLET BOX USING FACE OF THE DUPLEX OUTLET BOX USING " 4 4 4 4 0 3 4 4 3 4 4 SIDE VIEW A PLASTER RING EXTENSION SIDE VIEW A PLASTER RING EXTENSION CONTACT CHIP CUMMINS WITH CONTROL CO, INC. @ 615-636-5767 (CHIP@CONTROLCO.COM TO GYP.BD. METAL STUDS GYP.BD. METAL STUDS 150142 9 6'-10' FITTING 5A 5A 5A PURCHASE HIBBETT SPORTS ENERGY MANAGEMENT SYSTEM. ONLY THIS SYSTEM IS APPROVED FOR ELECTRICAL POWER PLAN ROOM 1�-0» 1 _6„ INSTALLATION. ELEC OUTLET ELEC OUTLET LOCATION: # 1294. • CONTACT CITY LIGHTING PRODUCTS TO PURCHASE LIGHTS & SENSOR SWITCHES AS NOTED ON BOX TOP VIEW BOX TOP VIEW 104 PLAN. A) RECEPT MTD ON SLATWALL C RECEPT MTD ON COLUMN DATE: FEBRUARY 2015 G.C. TO POUR CONCRETE TO FILL-IN CONDUIT TRENCH AFTER E.C. COMPLETES WIRING SHEET 1 ELECTRICAL POWER PLAN INSTALLATIONS PVC CONDUIT OPENINGHA E HAVE A, LEVEL, ,TRANSI ION. PREPARE I FOR NEW FINISH 4 SALES AREA RCPT. MOUNTING DETAILSE 1 E-1 SCALE: 3/16"=V-0" OVER CONDUIT OPENING IN SLAB. E-1 SCALE: NONE C) (D W > ., J = Q oo U J Q U W > co UZ U — Q — I-- J F-- Z I- Z QQQc� .J � N Q 0) Q M MENS WOMENS W TLT ROOM TLT ROOM > �- 103 D§�] TYPE T ceo wEK TYPICAL a a Q CL EXH 0 Lu EXH AN EXH FAN D D D D O A-5 an W," F-- z Ill O A-15 J v Y O O O O [ � _ _ cn D ® NL/EM Q Q NL/EM ® IF] N O ~> A-3L � wA-31 A- co 0 ¢ m N TYPE X 1 NL EM W - TYPICAL z¢ _ _ rn lil g z Q o A- o Z No Z .� LIGHTING KEYED NOTES 1 �° A- A- A-3 A-3 A-3 O EMERGENCY LIGHTS, NIGHT LIGHTS AND EXIT SIGNS SHALL BE CIRCUITED TO UNSWITCHED LOCKED CIRCUIT. NL EM NL EM NL/EM NL/EM NL/EM 1 1 O O O O LEVITON ODSIO-ID WALL-MOUNTED OCCUPANCY SENSORS (AQUIRED FROM LIGHTING VENDOR CITY LIGHTING TYPE N TYPICAL vj zzO � z � � wz PRODUCTS) IS TO BE INSTALLED TO CONTROL RESTROOM LIGHT(S), EXHAUST FANS(S) AN FITTING ROOM LIGHT. z ,. o a w o o_ w CIRCUIT CONTROLLING RESTROOM LIGHTS AND FANS, AND FITTING ROOM LIGHT IS TO BE ON A DEDICATED CIRCUIT - v7 � o w 0 ❑ w Of LABELED RESTROOM/FITTING ROOM". TYPE GG TYPI B TYPICAL w W W W Q Q W o w 0- TYPICAL � -iz wwm Z TYPE P o Q Q ❑ � a ~ o TYPICAL o } w = � z ~ O LIGHT FIXTURE SCHEDULE LAMP SCHEDULE 17 TYPE S Z a W w a 0 W U m U w U X TYPE F TYPICAL U) > wpomoc� � ws 01 REF LAMP WATTS FIXTURE MANUFACTURER TYPICAL LL QTY SYMBOL TYPE MANUFACTURER CATALOG NO. DESCRIPTION VOLTS REC SUR SUS WAL / / / ' > o U = a O � z a CE U NOTES FIXT LAMP WATTS CATALOG NO. TYPE M 0 1- m c� z o c� w z 2GR8428T8A-UNV w O z O m z_ RECESSED FLUORESCENT 2x4 SYLVANIA A-g o TYPICAL v � o � w � U ? z ~• O � 42 A METALUX QHE4X28T8/UNV 1,5 UNIV X 4 28 9 W z } o � U 0 WITH ACRYLIC LENSE F028/835/XPSS/ECO w m z m I- Q I- � m o ISNSCU-CLP w m a m W U) Z 00 m � � � 2GR8428T8A-UNV O u 0 a w �- p = W z RECESSED FLUORESCENT 2x4 SYLVANIA A- w -� o o N z U m 11 B METALUX QHE4X28T8/UNV WITH ACRYLIC LENSE EMERG NL 1,2,3, UNIV X 4 28 9 F028 835 XPSS ECO Z z ? o x LD = m ISNSCU-CLP-EL4 ( / ) / / / TYPE G NL EM O_ o O p w a o 3 = O A-3 A-3 A 3 'ly o `) v5 = zw0 E- WN228T8A-UNV SYLVANIA TYPICAL _ 1 cn x z 0 3 ® C METALUX QHE2X28T8/UNV SURFACE FW WITH ACRYLIC LEONSESCENT 1,5 UNIV X 2 28 4 F028/835/XPSS/ECO NL/ M NL/EM N_/EM PE A TYPICAL 0 o z Lu z o <. w o W o - Zw Zw � — — � ( wQ ZU � w ISNSCU-CLP 1 1 1 z Z) 0 O SSF128-UNVOS SYLVANIA O O O ~ o ma 2i 0 c=n U v o � aa- z 3 F METALUX QHE1X28T8/UNV 4 FLUORESCENT STRIPLIGHT 1,5 UNIV X 1 28 2 F028/835/XPSS/ECO ' U z m z cn z o ww o ' z w 2w ISNSCU-CLP y Q w � aOm _ U 0002 BTSSF128-UNVOS 8' FLUORESCENT STRIPLIGHT SYLVANIA ST CK SALES ARA o 0 o z z U z d m o z 0 10 �- -� G METALUX QHE2X28T8/UNV 1,5 UNIV X 2 28 4 {— z w U o o w - O TWO 4 FIXTURES 'IN TANDEM F028 835 XPSS ECO 1 0 o o ISNS-CLP ( ) / / / AREA Z - o E E- w 8TSSF128-UNVOS 8 FLUORESCENT STRIPLIGHT ~ o o W Y `� 0 ~ 0 SYLVANIA 1 1 A-3 O � O 000m � Ow a � X ° 6 GG METALUX QHE2X28T8/UNV (TWO 4' FIXTURES IN TANDEM) 1,2,3, UNIV X 2 28 4 F028 835 XPSS ECO 1 U 0 U U U z w w W a ISNS-CLP-EL4 (EMERG/NL) / / / 4' ONE CIRCUIT TRACK (WHITE) TYPE XX 5 K HALO LZR104P MTD W/ LZR207 T-BAR CLIPS 1,5,6 120 X NOT APPLICABLE 11 M HALO LZR108P 8' ONE CIRCUIT TRACK (WHITE) 1,5,6 120 X NOTA APPLICABLE A- 1 © COPYRIGHT 2014 MTD W/ LZR207 T-BAR CLIPS HIBBETT SPORTING GOODS, INC LIVE END FEED FOR SURFACE 8 ❑ N HALO LZR201 P MOUNTED TRACK (WHITE) 1,5,6 120 X NOT APPLICABLE REVISIONS: 8 - P HALO LZR212P MINIATURE STRAIGHT CONNECTOR 1,5,6 120 X NOT APPLICABLE FOR SURFACE TRACK (WHITE) _ _ GIMBAL RING TRACKHEAD 1 5 SYLVANIA 78440 NL3 M NL EM 6 54 0 S HALO LZR338P (SATIN WHITE W/ WHITE BAFFLE) 120 1 16 1 LED 16PAR38/DIM 830 FL40 G3 1 1 A-3 A3 A-3 2GR82U6T8-UNV RECESSED FLUORESCENT 2x2 SYLVANIA NL/ M NL1/ M NL/EM 3 F171 T METALUX QHE2X32T8/UNV WITH PRISMATIC LENSE 1,5 UNIV X 2 32 5 FB032/735O 1 ROBERT L. OUEATHEM ISNSC-CLP ENGINEERUNIVERSAL MOUNT LED EXIT LIGHT 3 ® X SURE-LITES HALLPX70RWH 1,3,5 UNIV X -- -- 3 INCLUDED LED 1 1950 CRAIG ROAD,sunr=3W sT.LOUIS,MO046 W/ INTERNAL NICKEL CADMIUM BXT. O PR(39)41s-2400 FAX(314)415-2300 www.arcv.com 1XX EXISTING EXISTING UNIVERSAL MOUNT LED EXIT LIGHT 1,3,5 UNIV X -- -- 3 INCLUDED LED A ® W/ INTERNAL NICKEL CADMIUM BXT. 1 ® Z BROAN MODEL #676 TOILET ROOM EXHAUST FAN 1,5 UNIV X -- -- 15 N/A 1 ® ZZ EXISTING EXISTING TOILET ROOM EXHAUST FAN 1,5 UNIV X -- -- 15 N/A v, III C LEVTON ODS10-ID WALL MOUNTED OCCUPANCY 1,5 UNIV X NOT APPLICABLE _ sx:. i! I MOTION SENSOR 3 ? REFERENCE NOTES: "% r Z 1 . REFER TO RESPONSIBILITY SCHEDULE ON SHEET T1. 2. FIXTURES SHOWN ON PLAN TO BE WIRED TO NIGHT LIGHT CIRCUIT. 3. FIXTURES USED FOR EXIT OR EMERGENCY LIGHTING TO BE ON LOCKOUT CIRCUIT. FITTING TYPE c 4. CONNECTOR HAS ANGLED FEATURE. TURN FEATURE 90' TO CONNECT TRACK AT ANGLED PORTION. SEE PLAN FOR TRACK TO CONNECT ® 90' ROOM TYPICAL 5. CONTACT STEVE BENTRUP ® CITY LIGHTING PRODUCTS (800-888-2572) FOR PROCUREMENT OF ALL LIGHTING SPECIFIED ON THIS SCHEDULE. 6. ELECTRICAL CONTRACTOR MUST INSTALL/CONNECT ONE (1) DEDICATED CIRCUIT TO EACH FEED CONNECTOR ® TRACK LIGHTING. 104 150142 1 ELECTRICAL LIGHTING PLAN LIGHTING PLAN E-2 SCALE:3/16"=1'-0" LOCATION: # 1294 DATE: FEBRUARY 2015 SHEET WHEN REUSING EXISTING PANELS, E.C. SHALL V RIFY THE CONDITION AND QUANTITY OF ALL EXISTING CIRCUIT BREAKERS. REPLACE DAMAGED BREAKERS WHEN REUSING EXISTING PANELS, E.C. SHALL VERIFY THE CONDITION AND QUANTITY OF ALL EXISTING CIRCUIT BREAKERS. REPLACE ELECTRICAL SPECIFICATIONS WITH NEW. PROVIDE ANY ADDITIONAL OR BREAKERS OF DIFFERENT AMPERAGE OR POLE AS REQUIRED TO MEET THE END RESULT INDICATED IN THE DAMAGED BREAKERS WITH NEW. PROVIDE ANY ADDITIONAL OR BREAKERS OF DIFFERENT AMPERAGE OR POLE AS REQUIRED TO MEET THE PANEL SCHEDULE. NEW BREAKERS SHALL BE OF THE SAME MFG AND CHARACTERISTICS OF THE EXISTING. THE SUBMISSION OF THE BID PROPOSALS END RESULT INDICATED IN THE PANEL SCHEDULE. NEW BREAKERS SHALL BE OF THE SAME MFG AND CHARACTERISTICS OF THE EXISTING. j 1. THE ELECTRICAL INSTALLATION SHALL COMPLY WITH THE CURRENT NATIONAL ELECTRICAL CODE AND ALL SHALL BE CONSIDERED EVIDENCE THAT THE CONTRACTORS HAVE VISITED THE SITE. NO EXTRA PAYMENTS WILL BE ALLOWED TO THESE CONTRACTORS THE SUBMISSION OF THE BID PROPOSALS SHALL BE CONSIDERED EVIDENCE THAT THE CONTRACTORS HAVE VISITED THE SITE. NO EXTRA Q U. STATE AND LOCAL CODES. ON ACCOUNT OF EXTRA WORK MADE NECESSAR BY HIS FAILURE TO VISIT THE SITE. PAYMENTS WILL BE ALLOWED TO THESE CONTRACTORS ON ACCOUNT OF EXTRA WORK MADE NECESSARY BY HIS FAILURE TO VISIT THE SITE. w > 2. PROVIDE CONNECTION OF ELECTRICAL EQUIPMENT MENTIONED IN THIS SECTION OR NOTED ON THE DRAWINGS, PANEL "A" CIRCUIT SCHEDULE PANEL "B" CIRCUIT SCHEDULE 0 _r WHETHER FURNISHED BY THE ELECTRICAL CONTRACTOR OR BY OTHERS. VOLTAGE: 120/208 VOLT, 3 PHASE, 4 WIRE; 200AMP MAIN LUG; SURFACE MOUNTED; TOP FEED; VOLTAGE: 120/208 VOLT, 3 PHASE, 4 WIRE; 200AMP MAIN LUG; SURFACE MOUNTED; TOP FEED; r 1 3. ALL WIRING DEVICES SHALL BE IVORY WITH SMOOTH IVORY PLASTIC PLATES, UNLESS OTHERWISE NOTED. ALL BUSSING SHALL BE COPPER; W/GROUND BAR. ALL BUSSING SHALL BE COPPER; W/GROUND BAR. Q V COND WIRE SI E BREAKER SPC CONN. LOAD KVA SPC BREAKER WIRE SIZE COND COND WIRE SIZE BREAKER SPC CONN. LOAD KVA SPC BREAKER WIRE SIZE COND Q LOAD DESCRIPTIONLOAD DESCRIPTION LOAD DESCRIPTION LOAD DESCRIPTION J 4. ALL WIRING INCLUDING LOW VOLTAGE TO BE IN CONDUIT. SIZE GND NEU 0 OL AMP NO• PH. A PH."B" PH."C NO AMP OL 0 NEUrd-N-D SIZE SIZE GND NEU 0 OL AMP NO. PH."A" PH."B" -PH."C" NO• AMP OL 0 NEU GND SIZE n 1200 » -- ui 5. ELECTRICAL CONTRACTOR SHALL FURNISH JUNCTION BOXES, CONDUIT, WIRE AND CONNECTIONS TO SIGNS STOREFRONT SIGN 3/4 12 10 10 1 20 1 4584 2 50 3 6 -- 1 RTU-1 BLANK -- -- -- -- -- -- 1 _- 2 -- -- -- -- -- -- BLANK O >� FURNISHED BY HIBBETT. XX LTG-EMERGENCY/EXITS/NL 3/4" 12 10 10 1 20 3 1348 4 BLANK -- -- -- -- -- -- 3 __ 4 20 1 -- -- -- -- SPARE 4584 co 6. THE TENANT SHALL MAKE APPLICATION TO THE LOCAL TELEPHONE COMPANY FOR TELEPHONE SERVICE. r , LTG-SHOW WINDOW 3/4" 12 10 10 1 20 5 4584 6 SPARE -- -- -- -- 1 20 5 6 20 1 -- -- -- -- SPARE `J 7. LOCATE OUTLETS AS INDICATED ON PLANS WITH MOUNTING HEIGHTS AS SHOWN. COORDINATE INSTALLATION 1400 WITH OTHER EQUIPMENT. SECURE OUTLETS TO STRUCTURE. LTG-SALES FLUORESCENT 3/4" 12 10 10 1 20 7 180 8 20 1 12 12 12 3/4 REC-CASH & WRAP P.O.S. XX SPARE -- -- -- -- 1 20 7 8 20 1 -- -- -- -- SPARE J 8. ALL CONDUCTORS SHALL BE CONTINUOUS FROM OUTLET TO OUTLET. AVOID UNNECESSARY SPLICING. LTG-SALES FLUORESCENT 3/4" 12 10 10 1 20 9 855 /540 10 20 1 12 12 12 3/4" REC-SECURITY EQUIP XX RTU-2 1" 10 - 6 3 50 9 4584 10 20 1 -- -- -- -- SPARE Z Z 9. THERE MUST BE A MINIMUM OF TWO STANDARD ELECTRICAL OUTLETS ON EACH CASH AND WRAP. THESE a `' LTG-SALES FLUORESCENT 3/4" 12 10 10 1 20 11 1540 12 20 1 12 12 12 3/4" PHONE/BUZZER/EMS XX 11 4584 12 20 1 __ __ __ __ SPARE � � co CLEARLY ELECTRICAL MARKED SHOULD NOT BE ON A CIRCUIT WITH ANY LIGHTING AND THE BREAKER SHOULD BE 903 4584 LTG-SALES FLUORESCENT 3/4 12 10 10 1 20 13 180 14 20 1 12 12 12 3/4 REC-CASH & WRAP P.O.S. XX 1,3 -- 14 20 1 -- -- -- -- SPARE N 10. ONE PHONE BOXES TO BE LOCATED 12" A.F.F. AT CASH AND WRAP NEXT TO EACH ELECTRIC OUTLET. -- ^ ' LTG-SALES TRACK 3/4" 12 12 12 1 20 15 580 16 20 1 12 12 12 3/4" REC-CASH & WRAP P.O.S. XX SPARE -- -- -- -- 1 20 15 16 20 1 -- -- -- -- SPARE CVV BOXES BACKBOARD AND TWO-LINE WIRING JACKS TO PROVIDE " 963 __ -- `- , 11. PROVIDE A COMPLETE SYSTEM OF CONDUIT, , LTG-STOCK/RR/CORRIDOR 3/4 12 12 12 1 20 17 180 18 20 1 10 10 12 3/4 SENSORMATIC SECURITY XX SPARE -- -- -- 1 20 17 -- 18 -- -- -- -- -- -- BLANK A COMPLETE OPERATING TELEPHONE SYSTEM. PROVIDE TELEPHONE WIRE & PHONE JACK FOR (2) TELEPHONE LINES AT EACH LOCATION SHOWN. SPARE -- -- -- -- 1 20 19 1440 20 20 1 12 12 12 3/4" REC-GENERAL SALES AREA BLANK -- -- -- -- -- -- 19. 201 -- -- -- -- -- -- BLANK 12. ALL ELECTRICAL EQUIPMENT UNDER THIS CONTRACT SHALL CONFORM TO THE APPLICABLE REQUIREMENTS OF -- THE LATEST EDITION OF THE FOLLOWING PUBLICATIONS: SPARE -- -- -- - 1 20 21 180 22 20 1 12 12 12 3/4" REC-CEILING 15' FROM DOOR BLANK -- -- -- -- -- -- 211 __ 22 -- -- -- -- -- -- BLANK ► U) (1) UNDERWRITERS LABORATORIES, INC. - U.L. (2) NATIONAL FIRE PROTECTION ASSOCIATION - NFPA SPARE -- -- -- -- 1 20 23 360 24 20 1 12 12 12 3/4" REC-SHOW WINDOW BLANK -- -- -- -- -- -- 23 24 -- -- -- -- -- -- BLANK � } � (3) NATIONAL ELECTRICAL MANUFACTURER'S ASSOC. - NEMA BLANK -- -- -- - -- -- 25 720 26 20 1 12 12 12 3/4" REC-MANAGERS DESK BLANK -- -- -- -- -- -- 25 261 -- BLANK �;; ■ z (4) NATIONAL ELECTRICAL CODE - NEC -- -- -- -- -- -- � BLANK -- -- -- - -- -- 27 - 28 20 1 12 12 12 3/4" REC-TRAINING BLANK -- -- -- -- -- -- 27' -- 28 -- -- -- -- -- -- BLANK0 13. SHEET METAL BOXES SHALL BE STANDARD TYPE WITH KNOCKOUT MADE OF HOT DIPPED GALVANIZED STEEL 720 -- 1:t, O_ AS MANUFACTURED BY STEEL CITY, RACO, OR EQUAL. BLANK -- -- -- - -- -- 29 30 20 1 12 12 12 3/4" WATER HEATER BLANK -- -- -- -- -- 29 30 -- -- -- -- -- -- BLANK W0 14. ALL CIRCUIT CONDUCTORS TO BE (2) #12, WITH #12 GROUND UNLESS NOTED OTHERWISE. - 1350 W z BLANK -- -- -- - -- -- 31 32 20 1 -- -- -- -- SPARE BLANK -- -- -- -- -- -- 31 32 -- -- -- -- -- -- BLANK _ O 15. PLATES FOR UNFINISHED AREAS SHALL BE SHEET STEEL OR CAST METAL AS SPECIFIED ON PLANS. __ v _ BLANK -- -- -- -- -- -- 33 900 34 20 1 12 12 12 3/4" REC-HVAC BLANK -- -- -- -- -- -- 33 34 -- -- -- -- -- -- BLANK 16. ALL PANELBOARDS SHALL REMAIN AND BE RE-USED. CIRCUIT BREAKER SHALL BE SWITCH RATED AND BOLT ON TYPE. BLANK -- -- -- -- -- -- 35 360 36 20 1 12 12 12 3/4" REC-RESTROOM BLANK -- -- -- -- -- -- 35 36 -- -- -- -- -- -- BLANK z Lu 17. PROPERLY IDENTIFY EACH SWITCH WITH A PLASTIC NAMEPLATE. BLANK -- -- -- - -- -- 37 38 20 1 -- -- -- -- SPARE BLANK -- -- -- -- -- -- 37 38 -- -- -- -- -- -- BLANK ul -- -- M W � � N 18. PROVIDE ENGRAVED PLASTIC IDENTIFICATION PLATE FOR EACH PANELBOARD. INSTALL TYPEWRITTEN DIRECTORY BLANK -- -- -- -- -- -- 39 __ 40 20 1 -- -- -- -- SPARE BLANK -- -- -- -- -- -- 39 __ 40 -- -- -- -- -- -- BLANK O ¢ m IN DOOR OF EACH PANEL CIRCUITS SHALL BE NUMBERED ALTERNATELY (i.e. 1,3,5, AND 2,4,6 ETC.). -- Lu W BLANK -- -- -- - -- -- 41 __ 42 20 1 -- -- -- -- SPARE BLANK -- -- -- -- -- -- 41 __ 42 -- -- -- -- -- -- BLANK z Q = N 19. USE ONLY APPROVED LUBRICANT FOR WIRE PULLING PURPOSES. rn Lit =� O U 20. SUPPORT OF ALL LIGHT FIXTURES SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. LAY-IN _ QLo LIGHT FIXTURES SUPPORTED ENTIRELY BY CEILING GRID SYSTEM SHALL HAVE "HURRICANE" CLIPS FASTENED LOAD PER PHASE10607 9883 9670 LOAD PER PHASE4584 4584 58 z o TO CEILING GRID. 4 4 (J N m Ov aU 21. SAFETY SWITCHES SHALL BE INSTALLED WHERE INDICATED ON PLANS OR WHERE OTHERWISE REQUIRED BY NOTE: ALL BREAKERS SHALL BE 20A BOLT-0 (VERIFY), UNLESS OTHERWISE NOTED. NOTE: ALL BREAKERS SHALL BE 20A BOLT-ON (VERIFY), UNLESS OTHERWISE NOTED. CODE CLLEARANCEORFOIRGOPERATIONIES.AND THEY SE SHALL EPLA EM REPLLED WITH ACEMENT. SWITCDHE(SHALL HAVE ENGRAVED,PLASTICUATE HAND ACCESS TO NAMEPLATES ISOLATED GND NOTE: E.C. TO BALANCE ALL PHASES WITHIN 10%. NOTE: E.C. TO BALANCE ALL PHASES WITHIN 10%. NAMEPLATES INSTALLED THEREON. T/C - INDICATES THIS CIRCUIT TO BE CONTROLLED BY A TIMECLOCK ` wv T/C - INDICATES THIS CIRCUIT TO BE CONTROLLED BY A TIMECLOCK * - CIRCUIT TO HAVE AN ISOLATED GROUNE AND ISOLATED NEUTRAL. IF NOT FOUND EXISTING, E.C. * - CIRCUIT TO HAVE AN ISOLATED GROUND AND ISOLATED NEUTRAL. 0 (D U- w >_ o w � F- 22. THE ELECTRICAL CONTRACTOR TO FURNISH A WRITTEN, SIGNED WARRANTY STATING; THATF"`ALL WORK " SHALL PROVIDE MINIMUM 1 #6 }' z F- I-z 0 p Q w p a w XX - INDICATES LOCK OUT CIRCUITS. XX - INDICATES LOCK OUT CIRCUITS. z EXECUTED UNDER THIS CONTRACT SHALL BE FREE OF DEFECTS IN WORKMANSHIP AND,.,MATERIAL FORA O ISOLATED GROUND. O O u) LO o_ w "" w 0 2 PERIOD OF ONE (1) YEAR FROM DAY OF FINAL ACCEPTANCE. THAT THE ELECTRICAL CONTRACTOR WILL-°-AT THIS OWN EXPENSE REPAIR OR REPLACE ALL DEFECTIVE WORK AND MATERIALS AND ALL OTHER WORK __ z w w z m ow z m a < DAMAGED THEREBY, WHICH BECOMES DEFECTIVE DURING THE TERM OF THE GUARANTEE-WARRANTY. - 3� �tA�►t �sGorl�lZ�-'+ (3) p���-.�..5 �• GENERAL ELECTRICAL NOTES o a z [Z w w m Q M o 23. CONTRACTOR SHALL SECURE ALL PERMITS. 1. ALL ELECTRICAL WIRING MUST BE IN CONDUIT. o w w p cn z WHEN REUSING EXISTING PANELS, E.C. SHALL VERIFY THE CONDITION AND QUANTITY OF ALL EXISTING CIRCUIT 'BREAKERS. REPLACE v ST �jt (_.� `, ,, _j 12 0 = g z � - O 2. ELECTRICAL EQUIPMENT EXPOSED TO WEATHER MUST BE WEATHERPROOF. Q z ~ o Q 0 w �' 1=- DAMAGED BREAKERS WITH NEW. PROVIDE ANY ADDITIONAL OR BREAKERS OF DIFFERENT AMPERAGE ,OR POLE AS,REQUIRED TO MEET THE p p 24. ELECTRICAL DRAWINGS ARE CONSIDERED DIAGRAMMATIC AND INDICATE GENERAL ARRANGEMENT ONLY. REFER w Q p w Z m w v TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS AND EXACT LOCATIONS, END RESULT INDICATED IN THE PANEL SCHEDULE. NEW BREAKERS SHALL BE OF THE SAME "MFG AND CHARACTERISTICS OF THE EXISTING. / 3. CONDUIT EXPOSED TO WEATHER MUST BE HEAVY WALL GALVANIZED STEEL. w �- 0 m O 0 0- w w THE SUBMISSION OF THE BID PROPOSALS SHALL BE CONSIDERED EVIDENCE THAT THE CONTRACTORS HAVE VISITED THE SITE. NO EXTRA ���Y�L� / A �, w i- z z a ,� PAYMENTS WILL BE ALLOWED TO THESE CONTRACTORS ON ACCOUNT OF EXTRA WORK MADE NECESSARY BY HIS FAILURE TO VISIT THE SITE. !!! � 0 o p = a o - CE v, 25. CONDUCTORS: COPPER, AWG #12 AND LARGER CLASS "B" STRANDED THHN OR THWN 600 VOLT, MINIMUM 4. ALL ELECTRICAL EQUIPMENT MUST BE U.L. APPROVED AND COMMERCIAL GRADE. p - 0 z 0 _ 0 w z 5. BARE TUBE FLUORESCENT FIXTURES FOR LIGHTING IS NOT PERMITTED IN SALES AREA. SIZE 12. ALL CONDUCTORS 6 AND LARGER SHALL BE IDENTIFIED. " �� w w 0 o w - 0 Z)0 m o ? Y # # PA EL C CIRCUIT SCHEDULE 6. NO CONDUITS TO BE RUN IN DUCTWORK. W w _ z 2 3 p U) m Q cn O 26. ALL SINGLE-PHASE BRANCH CIRCUITS, 120 VOLT LIGHTING, RECEPTACLES AND MOTORS SHALL CONSIST OF VOLTAGE: 120/208 VOLT, 3 PHASE, 4 WIRE; 200AMP MAIN LUG; SURFACE MOUNTED; TOP FEED; t ~ w m a m � U) z o •� cF 7. ALL TEMPORARY WIRING TO BE REMOVED WHEN STORE ROOM SERVICE IS AVAILABLE. "- 0 0 _ w F) � z = m z PHASE, NEUTRAL AND GROUND CONDUCTORS. L ALL USSING SHALL BE COPPER; W/GROUND,=BAR. cr w D w 0 p U m Q 27. FURNISH AND INSTALL COMPLETE GROUNDING SYSTEM, GROUND CONDUCTOR, COND WIRE SIZE BREAKER SPC CONN. LOAD KVA SPC BREAKER WIRE SIZE COND 8. ALL ELECTRICAL WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE CURRENT z 0 w - it - - GROUND ELECTRODES GROUND ° ~ o O O w a o = O LOAD DESCRIPTION LOAD DESCRIPTION /�, NATIONAL ELECTRICAL CODE AND ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES. o � m z w p w z p F- BUS & GROUND ROD TO EFFECTIVELY PROVIDE SERVICE GROUND. GROUND ALL PANELS,'= WIREWAYS, SIZE GND NEU 0 OL AMP NO PH."A" PH. B PH,"C" NO AMP OL NEU GND SIZE CONDUITS, LIGHT FIXTURES, RECEPTACLES IN ACCORDANCE WITH THE N.E.C. VERIFY GROUNDING MEANS WITH " _ 2856 __ _ __ __ e> 0 ( > w z o z ~ o 0 ~ W LANDLORD. RTU-5 1 10 6 3 40 1 __ 2 20 1 SPARE HVAC NOTE Z � ODEOD Q z ? o () a � 3 2856 4 20 1 -- - -- -- SPARE ~ g 0 ~ °- 28. GROUND CONDUCTORS SHALL BE INSTALLED IN ALL FEEDERS AND BRANCH CIRCUIT CONDUITS. ALL -- ELECTRICAL CONTRACTOR SHALL FIELD VERIFY EXACT REQUIREMENTS FOR HVAC UNIT (AMPS, U z 0 z z o ccn w EQUIPMENT GROUND WIRES SHALL BE COPPER AND SIZED AS PER N.E.C. TABLE 250-95. 2856 VOLTS, PHASE) SUPPLY ALL NECESSARY EQUIPMENT (WIRE, CONDUIT, FUSES, DISCONNECT Q w W Q Q o m ? Ov o oz 0 0 5 6 20 1 -- -- -- SPARE SWITCH CIRCUITt BREAKER, ETC) TO ENSURE SAFE AND PROPER UNIT OPERATION. IF Q o cn CO p o C) 29. ALL CONDUITS SHALL BE A MINIMUM OF 1/2" DIAMETER UNLESS OTHERWISE NOTED. ALL HOMERUN 4368 DISCREPANCIES ARISE CONTACT PROJECT REP. o v o z z z w m o w z 0 CONDUITS SHALL BE A MINIMUM OF 3/4" DIAMETER UNLESS OTHERWISE NOTED. ALL CONDUITS IN SLAB OR RTU-4 1" 10 - 6 3 50 7 __ 8 20 1 -- -- -- SPARE Z z I- g o o � - 0 S NOTED. � � 0 0pDo UNDERGROUND SHALL BE A MINIMUM OF 3/4 DIAMETER SCHEDULE 40 PVC UNLESS OTHERWI E N T -- w �- z z E co _ w_ NEW 208V, 10, 60A.S., N.F. z � zz 0 w Y " O 0 o 9 __ 10 20 1 -- -- SPARE U w00 0000DOW wawa 4368 FOR EXIST RTU-3 O � zzzmmo � aQwo 30. ALL CONDUITS TO BE 90' WHERE PENETRATING FIRE OR SMOKE RATED WALLS SO THEY, CAN BE PROPERLY 4368 EXIST 208V, 3�, 60A.S., N.F. 35.7 F.L.A. FIRE TREATED AND CAULKED. 11 __ 12 20 1 -- -- -- -- SPARE " FOR EXIST RTU-2 PANEL A DEMAND 38.2 F.L.A. W/ 11.3 ELEC HEAT- EXIST 208V, 30, 60A.S., N.F. MAIN ELECTRICAL 31. ALL EXTERIOR RECEPTACLES, JUNCTION BOXES, AND EQUIPMENT SHALL BE WEATHERPROOF. RTU-3 1" 10 - 6 2 50 13 3713 14 20 1 -- -- -- -- SPARE FOR EXIST RTU-4 DISCONNECT TO -- EXIST 208V, 30, 60A.S., N.F. 38.2 F.L.A. W/ 11.3 ELEC HEAT BE MARKED AND C COPYRIGHT 2014 DESCRIPTION TOTAL WATTS FOR EXIST RTU-1 ACCESSIBLE TO 0 32. INSTALL COMPLETE LIGHTING SYSTEM. FIXTURES, LAMPS, ACCESSORIES AND SUPPORT AS SPECIFIED AND 15 3713 16 20 1 -- -- -- -- SPARE EXIST 208V, 3�, 60A.S., N.F. FIRE DEPARTMENT. HIBBETT SPORTING GOODS, INC SHOWN. CEILING GRID LAYOUTS ON PLANS ARE FOR CONVENIENCE ONLY. THE CONTRACTOR SHALL -- 38.2 F.L.A. W/ 11.3 ELEC HEAT FOR EXIST RTU-5 COORDINATE THE LIGHT FIXTURE LAYOUT WITH WITH ARCHITECT, GENERAL CONTRACTOR, MECHANICAL LIGHTING & SIGN 8,578 23.8 F.L.A. REVISIONS: SPARE -- -- -- -- 1 20 17 18 20 1 -- -- -- -- SPARE 25% CONTINUOUS LOAD 2,145 ROOF LINE CONTRACTOR AND OWNER. -- - - - - - - - - - - - - 1 BD COMMENTS 04/02/15 SPARE -- -- -- -- 1 20 19 20 20 1 -- -- -- -- SPARE HVAC 13,752 EXIST LEASE LINE 33. LIGHTING AND RECEPTACLES CIRCUITS OVER 100 FEET FROM PANEL TO LAST OUTLET OR LIGHT SHALL HAVE -- 25% LARGEST MOTOR 1,737 2 16, 1"C ALL CONDUCTORS, INCLUDING GROUND WIRE, ONE SIZE LARGER THAN REQUIRED FOR AMPACITY FOR VOLTAGE SPARE -- -- -- -- 1 20 21 __ 22 20 1 -- -- -- -- SPARE RECEPTACLES 5,760 1 10 GND DROP. -- MISC 720 EXIST NEW 34. CIRCUIT NUMBERS ARE FOR IDENTIFICATION ONLY. THE CONTRACTOR WILL BE RESPONSIBLE FOR CORRECTLY SPARE -- -- -- -- 1 20 23 24 20 1 -- -- -- SPARE 3 #6 1"C 3 #6 1"C FIELD VERIFY EXACT PHASING THE CIRCUITS IN THE PANELS. HOMERUNS OF SIMILAR SINGLE PHASE CIRCUITS MAY BE COMBINED WATER HEATER 1,350 1 10 GND ' 1 10 GND METER REQUIREMENTS -- ROB . OUEATHEM IN ONE CONDUIT WITH A COMMON NEUTRAL. ONLY THREE SINGLE PHASE CIRCUITS MAY BE COMBINED IN SPARE -- -- -- -- 1 20 25 26 20 1 -- -- -- -- SPARE PANEL PANEL PANEL "*DISTRIBUTION ENGINEER ANY ONE CONDUIT. ON COMPLETION OF THE SPACE, THE CONTRACTOR SHALL BALANCE THE PANEL PHASE __ TOTAL DEMAND WATTS 34,042 EXIST 200A.S. WITH 2O0A.F. LOADS TO WITHIN 10% AS PER N.E.C. SPARE -- -- -- -- 1 20 27 28 20 1 -- -- -- -- SPARE A B SERVICE FROM LANDLORD 1850�"�R°A°,sut>�300 sr.souls,MO s31as TOTAL DEMAND AMPS 94.6 120/208V, 30, 4W ELEC. �(��415 2400 FAX(314)415 2300 www.arcv.can 35. NUMBER OF WIRES MAY NOT BE INDICATED FOR ALL CIRCUITS. ONLY THOSE WHERE CLARIFICATION IS SPARE -- -- -- - 1 20 29 30 20 1 -- -- -- SPARE REFER TO REFER TO REFER TO EQUIPMENT NECESSARY. THE ELECTRICAL CONTRACTOR SHALL PROVIDE ALL WIRES NECESSARY FOR PROPER FUNCTION PANEL PANEL PANEL OF THE SYSTEM WHETHER INDICATED ON PLANS OR NOT. SPARE -- -- -- -- 1 20 31 32 20 1 -- -- -- -- SPARE PANEL "B" DEMAND SCHEDULE SCHEDULE SCHEDULE 36. WIRING DEVICES: ALL DEVICES SHALL BE SPECIFICATION GRADE OF THE SAME MANUFACTURER. WALL EXIST yip i SPARE -- -- -- -- 1 20 33 34 20 1 -- -- -- SPARE 4 �3/0, 2"C ; ~•SWITCHES 20 AMP 120/277 VOLT, DUPLEX RECEPTACLES 2 WIRE 3 POLE GROUNDED 20 AMP 120 VOLT. -- DESCRIPTION TOTAL WATTS1 6GND SPARE -- -- -- -- 1 20 35 36 20 1 -- -- -- SPARE a , 37. RECEPTACLES MOUNTED IN FIRE OR SMOKE RATED WALLS SHALL BE A MINIMUM 25" APART. -_ -- HVAC 13,75 - - - - _ - - - - - FLOOR LINE z`- SPARE -- -- -- -- 1 20 37 _ 38 20 1 -- -- -- SPARE 25% LARGEST MOTOR 1,737 _ 38. DISCONNECT SWITCHES: HEAVY DUTY, ENCLOSED SAFETY SWITCHES, QUICK-MAKE, QUICK-BREAK TYPE WITH - S NOT FOUND EXISTING, E.C. INTERLOCKED COVER AND TYPE ENCLOSURE REQUIRED FOR THE LOCATION. FUSED TYPE SHALL BE EQUIPPED SHALL PROVIDE MINIMUM 1 WITH REJECTION TYPE FUSES. MANUFACTURER SHALL BE SQUARE "D GE, ITE OR CUTLER HAMMER. SPARE -- -- -- -- 1 20 39 40 20 1 -- - -- -- SPARE TOTAL DEMAND WATTS 15,489 ISOLATED GROUND. 'arm' SPARE -- -- -- -- 1 20 41 42 20 1 -- -- -- SPARE TOTAL DEMAND AMPS 43.0 P� ( 39. ALL EXHAUST FANS SHALL HAVE DISCONNECT SWITCHES, FIRESTATS PROVIDED BY THE MECHANICAL -- ELECTRICAL ONE-LINE DIAGRAM '3 CONTRACTOR INSTALLED BY THE ELECTRICAL CONTRACTOR. PANEL "C" DEMAND SCALE' NONE 150142 40. ALL REMOTE EQUIPMENT ON ROOF OR GROUNDS SHALL HAVE A DISCONNECT SWITCH AT EACH PIECE OF EQUIPMENT. LOAD PER PHASE10937 10937 7224 1. ALL WIRE SHALL BE COPPER ONLY;, THW, THWN, 3. ALL ELECTRICAL EQUIPMENT (PANELS, TRANSFORMER, ELECTRICAL PANEL SCH. & DETAILS DESCRIPTION TOTAL WATTS THHW, OR NEC APPROVED EQUAL OR BETTER. ALL LIGHTS, DEVICES, CONDUIT, WIRE, ETC.) NOT BEING WIRING SHALL BE IN CONDUIT. WIRE AMPACITY BASED USED SHALL BE REMOVED FROM THE SITE. LOCATION: # 1294 41. DEDICATED CIRCUIT, "LOCK OUT BREAKER FOR NIGHT LIGHTING, EXIT, EMERGENCY LIGHTS, CASH WRAP NOTE: ALL BREAKERS SHALL BE 20A BOLT-0 HVAC 29,098(VERIFY), UNLESS OTHERWISE NOTED. ON NEC 110-14c AND TABLE 310-16. DO NOT ABANDON IN PLACE. DATE: FEBRUARY 2015 AREA. _ OUTLETS, ALL SECURITY OUTLETS, OUTLET AT TELEPHONE BACKBOARD AND PLUG MOLD STRIP AT TRAINING NOTE: E.C. TO BALANCE ALL PHASES WITHIN 10%. 25% LARGEST MOTOR 1,395 2. E.C. SHALL FURNISH ALL NEW ELECTRICAL EQUIP. 4. E.C. SHALL FIELD VERIFY ALL EXISTING ELECTRICAL SHEET T/C - INDICATES THIS CIRCUIT TO BE CONTROLLED BY A TIMECLOCK (PANELS, TRANSFORMER, CONDUITS, WIRE, METERS, EQUIPMENT. ALSO FIELD VERIFY THAT ANY EXISTING 42. LIGHT FIXTURES SHALL BE FURNISHED AS SPECIFIED IN THE LIGHT FIXTURE SCHEDULE ON THE ELECTRICAL * LIGHTING PLANS OR APPROVED EQUAL. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY CEILING - CIRCUIT TO HAVE AN ISOLATED GROUND AND ISOLATED NEUTRAL. TOTAL DEMAND WATTS 30,493 SERVICE FEEDERS AND CONDUIT, DISC SWITCHES, ELEC. EQUIPMENT TO BE REUSED IS OF ADEQUATE TYPES, CLEARANCES, MOUNTING HARDWARE, ETC., AS REQUIRED TO INSTALL THE LIGHT FIXTURES. XX - INDICATES "LOCK OUT" CIRCUITS. CONTACTORS, TIMECLOCKS, ETC) AS REQUIRED, SIZE AND CONDITION TO MAINTAIN SAFE OPERATION. E3 TOTAL DEMAND AMPS 84.7 UNLESS NOTED OTHERWISE. IF DISCREPANCIES ARISE CONTACT PROJECT REP. Y ry TELEPHONE BACKBOARD J (4' x 8' x 3/4" PLYWOOD) U. W NOTA: LIGHTING C FACE OF RECEPTACLE AND CONTROL _, A)STOCK ROOM �+ TELEPHONE OUTLETS ARE TO FACE ���i PANEL B)SALES FLOOR CONDUIT IN WALL. FAILURE TO MEET FIVE (5)RIGID X111 W V THE REQUIREMENT WILL RESULT IN CONDUITS IN WALL FOR (II1� CONTROL•BUTTONS „ C)TRACK LIGHTING Q RE-INSTALLATION AT CONTRACTOR'S POWER& PHONE LINES 48" MAX AFF �� J r , EXPENSE jlllj CONDUIT D)SIGNAGE OVERRIDE v W 1� CONDUIT: RELAY FINISHED WALL FROM LIGHTING �. m 111j1 CONTROL PANEL TO SECURITY PANEL(BY 11111 SECURITY COMPANY) c) r III�� ❑ ❑ ❑ otw e Q STANLEY ❑ ❑ ❑ cl o F-o ' PANEL DOOR SECURITY z° z INSTALL NEW IG X1111 DUPLEX RECEPTACLE iliii PANEL ~ ` EMS PANEL II II FORTINET ROUTER CONDUIT FROM 1 Q Q (PROVIDED BY OTHERS) OUTSIDE 7 OUTSIDE OF PANEL E-4 SCALE: NTS �„ N INSTALL NEW IG iill 1 �LINE 1 PUBLISHED QUAD RECEPTACLE ��� II'll FINISHED FLOOR TWO(2)SECURITY (PUBLISHED) DUPLEX OUTLETS(#13) v' INSTALL NEW iill NETWORK POD "1" �'� Ilill LINE 2 iilll FROM ELEC �o� (UNPUBLISHED) 1 111 O O 1 PANEL ,00 TORK EWZ103 ASTRONOMIC INSTALL NEW IG 11ii1 6" A)STOCKROOM : - D a CLOCK TIMER DUPLEX RECEPTACLE � `����`` 11111 B SALES FLOOR e EMERGENCY OVERRIDE asr: 11111 RJ11 PHONE JACKS Q ) Z ONE PER EACH LINE 1 t CONNECTED TO SECURITY I I ( C)TRACK LIGHTING ALARM(CONNECTION w INSTALLED BY „A SUPPLIED&INSTALLED BY III I LINE 1JUNCTION BLOCK �- SERVICE PROVIDER I" ) D)SIGNAGE OVERRIDE SECURITY COMPANY) M„ �- S6,1911 ������� 1111 � � l a f: Q 3/4" RIGID CONDUIT �`�.``:`� j11i1 I I Lu TO DUPLEX �` II s F��,;;: LIGHTING CONTACTORS Li.1 �.`` �`� jllll INSIDE WIRING FROM _� <Yf W 0 � 1Uii PHONE JACKS I 2 RECEPTACLE VIA ��`�\\J11 — — — —LINE 2 JUNCTION BLOCK——— _ — _ - 1 1 Z TRENCH �;. a LOW VOLTAGE POWER (,(•j O FIVE (5)RIGID CONDUITS IN «> SUPPLY CONNECTED TO J FLOOR FOR POWER AND PHONE / TELEPHONE \ � ��..<,> .,.�...... ,..;rf` :,.,,...r ,.w;,.. ELECTRICAL PANEL T U LINES 6'-8"FROM FACE OF GYP / 4 BACKBOARD ELEVATION \ PANEL DOOR PANEL BD TO CENTER OF STUB UP / E-4 SCALE: NTS \ v' �O Z 5 TELEPHONE JUNCTION BLOCK CONNECTION DETAIL S\ p N 0L) / \ EMS PANEL uLu M j— F -- - - - -- - - ---- --- - -- -- --- � 8 INSIDE OF PANEL F- I-_ PODS "1" & 113" CONNECTIONS I E-4 SCALE: NTS w 0 0 < m CASH &WRAP POD"1" Z Q = CV ---------------------------------------, a = o ------------- ORANGE -I U co LLL - U .-. WHITE/BLUE WHITE/ORANGE I LINES 1 & 2 z 1 o BLUEBEEN iRED YELLOW BLACK BEEN iRED YELLOW BLACK I DATA O Z 0 eeee0 0 eeee0 I PHONE c N m 00 @� 1 CASH WRAP DETAIL I BLUE LINE 1 .INE 2 I D O CAT5 CONNECTOR O O CAT5 CONNECTOR E-4 SCALE: 1/2" = 1'-0" I I B B A A WHITE/BLUE WHITE/ORANGE I ORANGE-72 8"'--BROWN 2 8 ------- WHITE/ORANGE - 1 7 WHITE/BROWN 1 7 --------------------------------------- ORANGE I GREEN—�6 4—BLUE ORANGE- - 6 4—BLUE >_. MANAGER'S AREA POD"T' ( WHITE/GREEN—�-3 5—WHITE/BLUE WHITE/ORANGE-3 5—WHITE/BLUE O O w >_ p w F - —— — —— — — — — — — —— — — ——— ———— POD "4" CONNECTIONS GREEN& BROWN& Z Z Z O Q w O a w 4'-0" O.C. 4'-0" O.C. I PHONE BOARD POD "4" I WHITE/GREEN WHITE/BROWN O � O W q_ w W 0 I_- ------- - -=----------------------------------- I UNCONNECTED UNCONNECTED z W W z [0 O z m 0- W CAT5 CABLE CAT5 CABLE J - rz w w co Z X: p FAILURE TO MEET THESE REQ'D I ---------------- ORANGE I w z w p p w Z = w DIMENSIONS WILL RESULT IN I ; I p 4 Q LL 5 _ WHITE/BLUE '--- WHITE/ORANGE � RE-INSTALLATION AT BLUE OWE RED YELLOW BLACK GREE RED; YELLOW BLACK I w >- W w _j z ~ O CONTRACTOR'S EXPENSE I Q - U F- g Q o w - 8" MAX I e e e0e0 e e e0e0 LINE 1 AS LINE 1 LINE 2 AS LINE 1 v � Q O �' w cn m v w v NETWORK POD "1" I LINE 1 LINE 2 I PHONE PHONE w ' w ~ ❑ m 0 z ° w El El F- zF- - au ❑❑ � °' I o ° w � ¢ Ozo � c� wz ❑❑ 2 ( I f� O CAT5 CONNECTOR D O CAT5 CONNECTOR w 0 p �- Z z F- 0 w w I I A A A A W z ~ >- m23oc❑i� p � v� 0 Q Q Q L _ J 2 8 2 8 w � z F- (� mQ - N (V i� FINISHED — — — ——— — — — — — — — — ——— — —— — — —— — Z 1 7 1 7 1— a w cn O r •- 6 4—BLUE 6 4—ORANGE w co m a W E_ ~ U = w >- FLOOR 3 5-� WHITE/BLUE 3 5—WHITE/ORANGE O w p p Z_ U 00 Z 3/4" RIGID CONDUIT W/ 1 RIGID CONDUIT W/PHONE/ 3/4 RIGID CONDUIT W/ TELEPHONE BROWN& - BROWN& 5 Z w zD0WX - —L¢. DEDICATED CIRCUIT DATA LINES (REFER TO DEDICATED POS CIRCUIT(REFER JUNCTION BLOCK DETAIL WHITE/BROWN �'-ORANGE& WHITE/BROWN _BLUE& 0_ 1-- or, w a o = o REFER TO POWERED POWERED KEY NOTE"2B") TO POWERED KEY NOTE "2A") UNCONNECTED WHITE/ORANGE UNCONNECTED WHITE/BLUE vJ d � j Z W 0 wow 0 Cn Z O- Z ( E-4 SCALE: NTS GREEN& UNCONNECTED GREEN& UNCONNECTED O O w z P Z OO w O w KEY NOTE"2D") WHITE/GREEN WHITE/GREEN O Z 1- � U = W U U U � W 3/4" RIGID CONDUIT 6"AFF WITH 3/4" RIGID CONDUIT W/ LINCONNFCTFn CAT5 CABLE 11NC ONNFC:TFn CAT5 CABLE z � _ ❑ O w U p z ❑ O v TWO (2)PULL STRINGS ONLY(REFER DEDICATED CIRCUIT(REFER ❑ F- �- CL z TO POWERED KEY NOTE "2C") TO POWERED KEY NOTE"2D") Q w pw z ¢ O o w OU w z O 2 r2_'N� 9 CAT5 PLUG WIRING DETAIL ou � oo � Zwo p000 CASH WRAP ELEVATION E-4 SCALE: NTS w w F- O P E-4 SCALE: 1" = 1'-0" Z z F- O F.. ppi.L1 YL� � � _ � p F- z zzZmmw � ° Qwo � O o o o m D o w W P x cr PHONE LINES 1 AND 2: CAT-5 WIRE FROM TELEPHONE BACKBOARD U ❑ 000 = 0 > cn w d DATA A: CAT-5 WIRE 4'-0" 4'-0" 3'-0" 4'-0" DATA B: CAT-5 WIRE DATA C: CAT-5 WIRE © COPYRIGHT 2014 PHONE LINES 1 AND 2: CAT-5 WIRE FROM JUNCTION BOX ON TELEPHONE BAOKBOARD DATA D: CAT-5 WIRE SLATWALL STANDARD SLATWALL STANDARD B SPORTING GOODS, IN DATA E: CAT-5 WIRE DATA F: CAT-5 WIRE REVISIONS: PHONE LINES 1 AID 2: CAT-5 WIRE FROM JUNCTION DATA G: CAT-5 WIRE BOX ON TELEPHONE BACKBOARD DATA H: CAT-5 WIRE DATA J: CAT-5 WIRE ROBERT L. QUEATHEM ENGINEER 1850 CRAIG ROAD,3UfiE 300 Si.LOUR,MO 63146 A D A D F J F J PR(314)415-2400 FAX(314)415-2300 www.arcy.com H H H H E HRJ45 RJ45 no DATA DATA DATA DATA DATA DATA DATA DATA B E B E G G LINE 1/MODEM 0 00 1' , : RJ45 RJ45 RJ45 RJ45 RJ45 ❑ RJ45 ❑ � .,�'+ DATA DATA DATA DATA DATA BLANK DATA PHONE b TRAINING AREA =� C LINE 1&2 C H LINE 1&2 H LINE 2/DBU " �?d SECURITY EQUIP NETWORK POD"T' ih ih QUADPLEX MTD - 'cn RJ45 RJ45 RJ45 ❑ RJ45 ❑ RJ45 El QUADPLEX MTD HORIZONTAL DATA PHONE DATA BLANK DATA PHONE DATA PHONE ".Lu /JJ ? r ) • ; HORIZONTAL MANAGER'S DESK QUADPLEX MTDI HORIZONTAL c FINISHED FLOOR FINISHED FLOOR CASH&WRAP TELEPHONE BACKBOARD MANAGER&TRAINING TELEPHONE BACKBOARD � .•• �' z fry SEE DETAIL 6/E4 FOR DATA WIRING DETAILS. NETWORK POD"1' NETWORK POD 2 NETWORK POD 3 NETWORK POD 4 � r .. ; 3 MANAGER'S & TRAINING AREA RECEPTACLES_ 6 DATA WIRING DETAIL E-4 SCALE: 1/2" = 1'-0" E-4 SCALE: 6'" 150142 TELEPHONE &DATA DETAILS LOCATION: # 1294 DATE: FEBRUARY 2015 SHEET PLUMBING FIXTURE SCHEDULE PLUMBING CONTRACTOR'S NOTES FIXTURE DATA CONNECTION DATA ALL OF THE PLUMBING/PIPING WORK IS NOT AECESSARILY SHOWN OR NOTED ON THESE DRAWINGS. THE C) U. CONTRACTORSSHALL VISIT THE JOB SITE A D FIELD VERIFY ALL EXISTING CONDITIONS RELATED TO THE WORK PRIOR € WATER TO BIDDING.THOSE ITEMS NOT SHOWN OR NOTED BUT WHICH ARE DEEMED NECESSARY FOR REMOVAL OR 1 n CATALOG SOIL VENT RELOCATION BY OWNER OR HIS REPRESENT TIVE SHALL BE PART OF THIS CONTRACT.THE SUBMISSION OF THE v FIXTURE MARK QTY *MFG. COLOR TRAP REMARKS PROPOSALS SHALL BE CON-SIDERED EVIDENCE THAT THE CONTRACTORS HAVE VISITED THE SITE. NO EXTRA 2 ,.,,..,..»»».,,...................»,....,..,..........,,.,,,.. ,_._... »».» »...,»....., » W.C.O. - NO. SIZE SIZE COLD HOT PAYMENTS WILL BE ALLOWED THESE CONT CTORS DUE TO EXTRA WORK MADE NECESSARY BY HIS FAILURE TO VISIT --- - ------------'------------ ------------ ---------- ----- ------------------------------------------------------ ,» . »..,,,...,..,,.,,»,... ..,.. ., ,,,,,..,,, .» »..»..,.. M WATER CLOSET WC-1 1 AMERICAN 2467.016 WHITE 4" 2" 4" 1/2" WHITE,OPEN FRONT, HINGED SEAT A---- --- --------;---------------- THE JOB SITE. », »»»,» y»,,,»,,,,,,,, STANDARD W/TANK# RIGHT HAND TRIP LEVER 4142.800 DO NOT ATTACH ANYTHING DIRECTLY TO THEDECK OR DUCTWORK ABOVE.ALL EQUIPMENT SHALL BE FASTENED TO < F € U W AMERICAN WHITE,OPEN FRONT, HINGED SEAT, € , WATER CLOSET WC-2 1 2467.016 WHITE 4" 2" 4" 1/2" -- THE TOP CHORD OF JOISTS OR TOP OF BEA S. STANDARD LEFT HAND TRIP LEVER I <�. Ip I 3 AMERICAN LUCERNE FAUCET 4"CTRS.POP-UP 21"x18" 4 D LAVATORY LAV 1 WHITE 1-1/2" 1-1/2" 1-1/2" 1/2" 1/2" WRITTEN DIMENSIONS HOLD PREFERENCE OVER SCALED DIMENSIONS. LAV STANDARD 0355.012 VITREOUS CHINA.PROVIDE GRID WC 1 LAV NEW sE ` STRAINER, UNDER LAV.TEMPERING (NEW) (RELO'D) (NEW) WC-2 USK DO NOT SCALE DRAWINGS. v V VALVE,AND TRUBRO INSULATION (NEW) ( `I (RELO'D) I``,� >I �� KIT CONTRACTOR'S MUST VISIT JOB SITE TO VE IFY ALL EXISTING CONDITIONS AND DIMENSIONS. ANY DISCREPANCIES IN I�<� f *J.R. ____ __ SEE �� �� WALL CLEANOUT WCO 1 SMITH RISER -- '- -- SEE SANITARY RISER THIS SHEET EXISTING CONDITIONS AS SHOWN SHOULD B BROUGHT TO THE ATTENTION OF HIBBETTS CONSTRUCTION DEPARTMENT AND CLARIFIED BEFORE SUBM TTING BIDS. CHANGE ORDERS WILL NOT BE ALLOWED FOR ANY WORK ="' "` „ #SF FAUCET,#SD DRAIN,#HH-30" � � 'I ; UTILITY SINK USK 1 RELOCATED -- WHITE 2' 2" 1-1/2 1/2" 1/2" REQUIRED DUE TO EXISTING CONDITIONS N T BEING FIELD VERIFIED BY CONTRACTOR PRIOR TO SUBMITTING BID. 3 Z � Z HOSE&BRACKET WH 1 Ai; ! K Q Q co ELKAY BI-LEVEL, BARRIER FREE, NON REPORT DISCREPANCIES DURING BIDDING P OCESS AND BEFORE START OF CONSTRUCTION WHICH MAY INTERFERE co DRINKING FOUNTAI DF 1 -- -- 1-1/2" 1-1/2" 1-1/2" 1/2" -- WITH THE PROPER EXECUTION OF WORK TO IBBETT'S CONSTRUCTION DEPARTMENT PRIOR TO COMMENCEMENT OF (NEW) III J J ' EDPF217C REFRIGERATED, NO ELEC REQ'D ANY WORK. , sI r N * OR APPROVED EQUAL 1 ABOVE I ?` V J N ( li ; II I I z CEILING < co PLUMBING FIXTURE CALCULATIONS PLU BING KEYED NOTES 5 , SANITARY SANITARY SANITARY CW CW O1 EXTEND AND CONNECT NEW 4" SANITARY TO EXISTING SANITARY. FIELD VERIFY EXACT LOCATION, SIZE � VENT AND DIRECTION OF FLOW. PLUMBING FIXTURE MARK FIXTURE FIXTURE FIXTURE FU FUSIZE -..-,..».-,.,�.M.� .,...,., ....::..... ......:............:::.............»..,,,,,„........,,.:.::-....,.,.....» ..,�I; �,. LLi ..... _.. ::: . QTY.. UNIT EA. UNIT TOTAL EACH TOTAL 2 EXTEND NEW 1” COLD WATER PIPING TO EXISTING COLD WATER PIPING. FIELD VERIFY EXACT LOCATION »:'�':(�»`���� AND SIZE. 1711iii` »,»,,,,»„ €WATER CLOSET WC 2 4 8 2 5 10LAVATORY LAV 2 1 2 1-1/2” 2 4ALL EXISTING PLUMBING AND PLUM ING FIXTURES NOT BEING REUSED SHALL BE REMOVED. REMOVE ANDCAP EXISTING WATER AND SANITAR LINES BACK TO A POINT OF REUSE. FIELD VERIFY EXACT LOCATIONSDF `AND SIZES. REFER TO ARCHITECTU AL SHEET D-1. MAINTAIN INTEGRITY OF EXISTING CONDENSATE (NEW) QCL UTILITY SINK USK 1 2 2 2" 3 3 TERMINATIONS. FIELD VERIFY/CORR (NATE W/ MECH. CONTRACTOR. WDRINKING FOUNTAIN DF 1 1 1 1-1/2" 0.5 0.5OEXISTING EXTERIOR BACKFLOW PR ENTER TO REMAIN. FIELD VERIFY EXACT LOCATION AND SIZE. ENSURE W H QBACKFLOW IS FOR THIS SPACE. Lu 1 TOTAL 13 TOTAL 17.5 SAN. VENT CW O5 PROVIDE P-TRAP IN WALL AND RU WASTE IN WALL TO DISCHARGE INTO VERTICAL RISC BEHIND UTILITY 3 M SINK. Q SERVICE CONNECTION SIZE 4" 4" 1" Al � Z l WATER HEATER SCHEDULE " ` W � a N U 1 ENLARGED TOILET ROOM PLAN � p ¢ P-1 SCALE: 1/2" = V-0" ELEMENT WATTS Z x MODEL TEMP ._ .-r.,- FIXTURE MARK QTY *MFG. NO CAPACITY RECOVER WATTS VOLTS PHASE RISE WATER HAMMER a x LOWER UPPER W ARRESTER I■A■■�� H o WATER HEATER WH-1 1 ARISTON P-10S 2.5 GAL 8 GPH 1350 120 1 90° F 1350 -- ¢ o Z * OR APPROVED EQUAL C'3 N q O NOTE: PROVIDE T& P RELIEF VALVE,AND DRAIN TO APPROVED RECEPTACLE LOCATION 4. I N -U.S.K. ` RELO' 1/2#9 c� C7 w w >- W W F- VACUUM BREAKER WATER HEATER � 1 I z z z 0 Ox z w W w w TURN LEAD DOWN PROVIDE TRAPPING �� W.C.-2 p w of LL w0 O 2 INTO STACK GATE VALVE (TYP) PER CODE PIPE NEW w w w H' m w a. ~ ----- 1 LIP LAV. 1/2 NEW • 3/4 0 m a SHEET LEAD FLASHING ELECTRIC UNION Q SEAL PIPE INSULATION ',F NEW 1 2 o z H 0 o m o a MOP-IN WITH ROOFING I AT FLOORS, WALLS AND / " N WH w w Qz Qw _ _.. MATERIAL �__ __� I PIPE SLEEVE GYP. BD. CEILING RELO'D 3/4,. 3/4., w , W = Q o U ~ z 12 MIN - T&P RELIE VALVE (----� 3/4 Q �` z F- -� ¢ z p w N - „ 1/219 Q' mm U F- DISCHARGE TO PAN ° a s ° 3/4 m w a 0 w z c9 O U ROOFING a a %/2 1» I > 0 � = ¢ o _O _z aLL U F- H W.C.-1 0 F- u) ( zo - 0 w z NEW . . w wo0Z Jpm zzOY z w _ -- ------- --- �� " -\ » W w u~j z m 2 U cin >- U) o -- 24 ID x 2-1 " 1 ET 3 FIRE RETARDANT MATERIAL TO BE ✓ 1 NOTE: BID LEVEL o w m Q m < X Z O m 2 H >- GALV. SHEET METAL U.L.APPROVED FIRE SEAL EXTEND AND CONNECT NEW .. w 0 on w F- w z Z w z 1 C.W. TO EXISTING COLD ALL NEW HOT AND COLD Z = REQ'D AIR GAP PER DRAIN PA 1 -s vi w p cn 0 U m Q MATERIAL TO MAINTAIN ASSEMBLY WATER LINES SHALL BE ~ O O 0 w a = 0 SLEEVE ROOF ROOF STRUCTURE CODE % a z 0 o o w - = m w RATING BETWEEN PIPE&SLEEVE. WATER PIPING. FIELD VERIFY Cn = z w O o O _ EXACT SIZE AND LOCATION. INSULATED , cn > z a: z 0 0 0 � z 0 z CONSTRUCTION I z > w U (D w 0 z AS REQ'D ---II = z F- z w - w INCREASE AS REQ'D iz— O z � � oO � UpU z � ww -------- - - - - - BACKFLOW EXISTING XPREVENTER 0 TERIOR 0 0 z m w z w m 0 z C - - - - - - - - - - - - - - � MATERIAL U.L. NUMBER REQ'D w w Q bf Q p m z w cn c) z o GYPSUM WALL pU oww0o8m � OUZOU 5 WATER RISER DIAGRAM wF- ~ ~ � � w ~P CE 0 ~ � STEEL PIPE 428 z � 0 � OOw � Yw OF- Ure I 1 1/4" PAN DRAIN. ROUTE TO WATER HEATER STEEL PIPE W/INSULATION 444 P-1 SCALE: NONE ' Q z z z m m o 0 a w o FLOOR DRAIN OR APPROVED PLATFORM OVER COPPER PIPE 442 U w o O O O = mow a- � w a RECEPTACLE LOCATION. TOILET ROOM, SEE COPPER PIPE W/INSULATION 445 A-1.0 2 VENT THRU ROOF DETAIL rTN� WATER HEATER MOUNTING DETAIL 4 _ PIPE SLEEVE DETAIL © COPYRIGHT 2014 P-1 SCALE: NTS P-1 SCALE: NTS P-1 SCALE:NTS+ 11/2��V � �� HIBBETT SPORTING GOODS, INC _ EXTEND NEW 2" VENT TO 2"V 2'V EXISTING VENT PIPING. FIELD ` ` REVISIONS: WASTE OR VENT LOCATION. SIZE AND N ` MAY EXTEND AS VERIFY ry � -�' I I � NEW 3"\�� 1 BD COMMENTS 3/8" C.W. _ I 11/2 W i W. .0. �` PLUGGED TEE W/ I SUPPLY 5 MAX. 11/2„V I U.S.K. N`.�/11/2"V 1 CLEANOUT HANGER ROD ?. 2'V I I LO D �\ CHROME WALLCOVER o I 2"W AND SCREW II ' ' 3" I ROBERT L. OUEATHEM PUSHBAR o i I 11 „W 4"w I 3"W 2"W EXIST. 2"V"T I /2 3'W LAV', 11/2'yy ENGINEER 18-3/4 (18 MIN.) I I W.C.-2 RELO D 1M cRuc ROAD,SurrE 300 S-r LOUIS,Mo Ww FINISHED FLOOR i 4'W PH.(314)415-2400 FAX(314)415-2300 www.arcv.com 4. LAV. NEW PIPE INSULATION I RELO'D 11/4W i 2 W (--� BI-LEVEL _—I o I " EXTEND AND CONNECT NEW D.F. EXIST. 4 W 4 SAN. TO EXISTING SAN. 1/8 BEND IF CLEANOUT _� 1/8 BEND INSULATION SHALL BE RUN C NT. N i PIPING. FIELD VERIFY EXACT a ' i 1 a< � OCCURS AT END OF LINE I i— -I THROUGH HANGERS ., ct? WASTE LINE, LENGTH ch W.C.-1 K a - r, SIZE, LOCATION, AND � TO SUIT DIRECTION OF FLOW. ---'__ PIPE EXIST. 4"W (N"W FLOOR WASTE LINE �� NOTE: INSULATION PROTECTION SHI LD. y�--• ✓Y USE 16 GAUGE SHEET STEEL, ALL NEW VENT PIPING PASSING r �' — STONE BASE PIPE DIAMETERS LONG, 120 THROUGH CEILING PLENUM _ DEGREES SUPPORT, OR GRIN EL 1-1/4" AREA SHALL BE CAST IRON. —III—III—_— I I—I FIGURE 167. DRAIN 0 ` j I—1 I I I=1 • 1-1/4" 8 1 yr SANITARY RISER DIAGRAM DRAIN P-1 SCALE: NONE 1 PUSHBAR O 50142 PUSHBAR PLUMBING SCHEDULE AND DETAILS LOCATION: # 1294 6 WALL CLEANOUT DETAIL 7 PIPE HANGER DETAIL 8 DRINKING FOUNTAIN DETAIL DATE: FEBRUARY 2015 P-1 SCALE: NTS P-1 SCALE: NTS P-1 SCALE: NTS SHEET Pel