Loading...
1470 OCEAN BLVD HVAC CITY OF ATLANTIC BEACH 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 MECHANICAL HVAC PERMIT MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 15-MECH-884 Job Type: MECHANICAL HVAC ONLY Description: 1 CU 1 AHU 2.5 TONS Estimated Value: Issue Date: 4/16/2015 Expiration Date: 10/13/2015 PROPERTY ADDRESS: Address: 1470 OCEAN BLVD RE Number: 171855-0000 PROPERTY OWNER: Name: WADE JR, WILLIAM D & SARAH, Address: 1470 OCEAN BLVD GENERAL CONTRACTOR INFORMATION: Name; ONE HOUR AIR Address: 1015 ATLANTIC BLVD APT 249 QA CRAIG FARRELL EDDY Phone: - - PERMIT INFORMATION: Sticker for overcurrent protection must be on A/C equipment prior to inspection. Failure to comply will result in a failed inspection and reinspect fees. No eomeptions. FEES: Furnaces and Heating $20.00 AC and Refrigeration $20.00 State Mach DBPR Surcharge $2.00 State Mech DCA Surcharge $2.00 Trade Permit Base Fee $55.00 Total Payments: $99.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach,Fl,32233 Ph(904)247-5826 Floc(904)247-5845 JOBADDRFSS: 1,V1 6 n0FAM a3L-\Jr-,, -ABr FL_ 32Z5 3 ERMIT# I PROJECTVALUE $ WaSO _ ARI# -1995) ) 3 -REQUIRED _.Air Handling Equipment Only X_Air Handling Unit& Condenser _Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating— Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity TonsPerUnit 2-5 Heat: Unit Quantity I BTU's Per Unit zepco Seer Rating—ML— Duct System: Total CFM REQUIRED Manual J documentation required on residential change out FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requims 3 sets of plans) Fire Suppression Systems Quantity (Requim 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace Qty_ Automobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's # Water Heaters Solair Collection Systems Tanks (gallons) Wells OTHER: Penndbecmrus,�.id if wokti.n.autoommence.ithin a six month period or work is suspended or abandoned for six months.I herebycertily that I have read this application and know the same to be true and t. All provisions oflaws and ordintuates,governing this work will be complied with whether specified or not. The permitdoes not give authority to violate the provisions ofany other stre or loaal law regulation construction or(he performam,e ofconsaraction. Property Owners Name VC)Z,_� Phone Number to_�l - (�ka-73 a Mechanical Company (nAle �-6urc 01A -Office PhoneZqt-SW FaxZ92-5_'�Z6 Co. Address: 1199 City.4jZ#A_ffA�,&14 StateFZ Zip.32Z33 License Holder(Print): CMiCr_F_ -Slatofertification/Re2istration#cacIA)(4t/zo Notarized Sis attire of Licen& Holder S111LEYLW /da AP L'�, X*r C this RFSfelotan,14,2014 ABU re of N( y P,ib Certificate of Product Ratings AHRI Certified Reference Number: 7995113 Date: 4/1612015 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: GSZ140301K* Indoor Unit Model Number: ARUF31B14A* Manufacturer; GOODMAN MANUFACTURING CO., I.P. Trade/Brand name: GOODMAN; JANITROL;AMANA DISTINCTIONS; EVERREST; ONE HOUR AIR CONDITIONING AND HEATING; ENERGI AIR Series name: GSZ14 Manufacturer responsible for the rating oflhis system combination is GOODMAN MANUFACTURING CO., LP. Rated as follows in accordance with AHRI Standard 2101240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 28000 EER Rating (Cooling): 12.00 SEER Rating (Cooling): 14.00 Heating Capacity(Btuh)@ 47 F: 27800 Region IV HSPF Rating (Heating): 8.20 Heating Capacity(Btuh) @ 17 F: 16200 Ratings followed by an weens,I')Greens a voluntary rome,of prevously supaxived do. Irlace ccurn,red wer,G WAS.which ficheauser an xrvch�ntwy rarely, DISCLAI MER AHRI does not endorse the preed.cps)Inated!up this Carfificuts and makes no representations,warrantles of guarantees as fic,and assurnes no responalfivilryfor the produi pred In this Cadlyficatic.AHRI expressly clurnimms all liability for dannaps of any kind arising out of the use or performance of the products),or the mranG.Hzed!allocation of data listed on this certificates Certified rating are valid only for models and configurabons listed in the directory at wwwrahrIdirp1ory�o#,, TERMS AND CONDITIONS du ndV,xRr,',d.`d=,a,n.dxd. JIM This Comficris and its contents are proprietary products&AHRI.This Cartillcat,shall only be used for I p confidential reference,pur,vieves.The concepts of this Certificate may not,In whole or In part Ne apropticar, . en!:red into a computer database;or Otherwise trilized,In any form or manner or by any means,except forthe ursir's individual, pe onal and confidential reference. I.-C...IGNea., CERT Tho I :FICATE VERIFICATION A REFRIGERATION INSTITUTE and anormadon for the model cool on this redificate con be verified at www.ahridireaory.org,dick on'Verify Cortificame.link star the ARM Carthfical Reference Number and the date on which the seentificate was issued, which is listed advise.and the Certificate No..which is listed at bottom right. 1 @2014 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 1307W6248799SS524