1889 BEACH AVE HVAC CITY OF ATLANTIC BEACH
800 SEMINOLE ROAD
ATLANTIC BEACH,FL 32233
INSPECTION PHONE LINE 247-5814
MECHANICAL HVAC PERMIT
MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814
JOB INFORMATION:
Job ID: 15-MECH-999
Job Type: MECHANICAL HVAC ONLY
Description: 1 cu 1 ahu 3.5 tons
Estimated Value:
Issue Date: 5/4/2015
Expiration Date: 10/31/2015
PROPERTY ADDRESS:
Address: 1889 BEACH AVE
RE Number: 169686-0000
PROPERTY OWNER:
Name: BISBANO TRUST, DOMINICK
Address: 1889 BEACH AVE
GENERAL CONTRACTOR INFORMATION:
Name: DONOVAN HEATING &AIR
Address: 315 SIXTH AVENUES QA WILLIAM J DONOVAN
Phone: - -
PERMIT INFORMATION: Sticker for overcurrent protection must be on A/C equipment prior to
inspection. Failure to comply will result in a failed inspection and reinspect fees. No
exceptions.
FEES:
Furnaces and Heating $24.00
AC and Refrigeration $28.00
State Mech DBPR Surcharge $2.00
State Mech DCA Surcharge $2.00
Trade Permit Base Fee $55.00
Total Payments: $111.00
PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA
BUILDING CODES.
---------------
MECHANICAL PERMIT APPLICATION
CITY OF ATLANTIC BEACH
800 Seminole Rd Atlantic Beach, FL 32233
Ph(904)2447-5826 Fax(904)247-5845
FOB ADDRESS: Sfff4 IAe,,cK AjcA1
�-I1f.D.`�-r L ljK.QLQERMIT#
PROJECT VALUE $ Lf WN ARI# REQUIRED
_Air Handling Equipment Only XAir Handling Unit & Condenser _Condenser Only
NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit Seer Rating
Duct Systems: Total CFM REQUIRED
REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION
Air Conditioning: Unit Quantity Tons Per Unit
Heat: Unit Quantity BTU's Per Unit tQEC77 Seer Rating—Iq
Duct Systems: Total CFM R QE UIRED
FIRE PREVENTION
Fire Sprinkler System Quantity (Requires 3 sets of plans)
Fire Standpipe Quantity (Requires 3 sets of plans)
Underground Fire Main Value (Requires 3 sets of plans)
Fire Hose Cabinets Quantity (Requires 3 sets of plans)
Commercial Hoods Quantity (Requires 3 sets of plans)
Fire Suppression Systems Quantity (Requires 3 sets of plans)
FIRE PLACES MISCELLANEOUS:
Prefabricated Fireplace QtyAutomobile Lifts
Gas Piping Outlets Boilers BTU's
Elevators/Escalators
ALL OTHER GAS PIPING Heat Exchanger
Quantity of Outlets Pumps
#Vented Wall Furnaces Refrigerator Condenser BTU's
#Water Heaters Solar Collection Systems
Tanks(gallons)
Wells
OTHER:
Permit becomes void if work does not commence within a sin month period or work is suspended or abandoned for six months.I hereby certify that 1 have read
,is application and know the same to be true and correct. All provisions of laws and ordinances governing this work will be complied with whether specified or
at The permit does not give author�}t�ro viole(e the provisions of my other state or local law regulation conmucfiom or the performance of construction.
Property Owners Name sF ,@(„M\� By CAnb Phone Number ('.13-4 S
Mechanical Companyr�kt4"Y.f JA4S- r'! Sjt 1,C Office Phone 226Fax
Co. Address: � 15 / 1� 1' Alit. '�OUlOh City- tate T71 Zip3','' 6R)
1
License Holder(Frio[): ( ,l . 1\ �9"` pt" Stale Certification/Registration# 7 �.
Notarized Signature of License Halder I .11 i w
+t+.'i''.'iry^ RICHARD TOMPKINS Before me this day of AQP. 20 IS
A Comm¢sily FF 010399 /)
A Expires July 29,2017 Signature of Notary Public 1/-Qs/'�/
....p.` amt lTh lm FsiewmMa6F0Y
I
wrightsoft° Project Summary Job:
Date: 4MI15
Entire House By: Brandonzahade
Donovan Heat &Air
315 61M1 ave aMN,Jackamvilk Beam,FL 322W Ph-a,241-3785 Email:Ma iJcn@awvala;.com
Proiect Information
For: Dominik
1889 Beach,Atlantic Beach, FL 32233
Notes:
Design Information
Weather: Jacksonville Mayport Naval, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 39 'F Outside db 95 °F
Inside db 68 °F Inside db 75 °F
Design TO 29 °F Design TO 20 `F
Daily range L
Relative humidity 50
Moisture difference 53 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 17933 Btuh Structure 15831 Btuh
Ducts 6147 Btuh Ducts 12188 Btuh
Central vent(33 cfm) 1054 Btuh Central vent(33 cfm) 727 Btuh
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 25135 Btuh Use manufacturer's data n
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 28746 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 1 (Average) Structure 1948 Btuh
Ducts 2178 Btuh
Hast'i Cooling Central vent((33 cfm) 1196 Btuh
Area(k') 1794 1794 Equipment lafent load 5322 Btuh
Volume(fl') 16146 16146
Air changes/hour 0.45 0.20 Equipment total load 34068 Btuh
Equiv.AVF(cfm) 122 54 Req. total capacity at 0.70 SHR 3.4 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade Trade
Model 25HCD442 Cord 25HCD442
ARI ref no. 6938338 Coil FX40NF043
ARI ref no. 6938338
Efficiency 8 HSPF Efficiency 14 SEER
Heating input Sensible cooling 28778 Btuh
Heating output 40908 Btuh @ 47'F Latent cooling 12334 Btuh
Temperature rise 27 °F Total cooling 41112 Btuh
Actual air flow 1370 cfm Actual air flax 1370 cfm
Air flaw factor 0.057 cfnVBtuh Air flaw factor 0.049 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.84
Printout certified by ACCA to meet all requirements of Manual J 8th Ed.
�rwrlgbfsoft R4aMSuilcb umiiaael 7.1.01 RSUOS936 2015 ,2118.16:46
C'.1Uli—%Saks%DooUma.MW1hl.011 HWC13.5TON Calc=MA 0 mam.n=N Pa0e1