2233 SEMINOLE RD #011 CITY OF ATLANTIC BEACH r 800 SEMINOLE ROAD ATLANTIC BEACH,FL 32233 INSPECTION PHONE LINE 247-5814 MECHANICAL HVAC PERMIT MUST CALL BY 4PM FOR NEXT DAY INSPECTION: 247-5814 JOB INFORMATION: Job ID: 15-MECH-1274 Job Type: MECHANICAL HVAC ONLY Description: 1 c 1 ahu 3 tons UNIT 11 Estimated Value: Issue Date: 6/112015 Expiration Date: 11/28/2015 PROPERTY ADDRESS: Address: 2233 SEMINOLE RD UNIT 011 RE Number: 169519-0122 PROPERTY OWNER: Name: BERRY, MADELINE L ET AL Address: 2233 SEMINOLE RD APT 11 GENERAL CONTRACTOR INFORMATION: Name: AIR SOURCE AMERICA INC Address: 2615 CRYSTAL COVE CT RICHARD E EPPERSON JR Phone: 904-233-8831 PERMIT INFORMATION:Sticker for overcurrent protection must be on A/C equipment prior to inspection. Failure to comply will result in a Palled inspection and reinspect fees. No exceptions. FEES: Furnaces and Heating $24.00 AC and Refrigeration $24.00 State Mech DBPR Surcharge $2.00 State Mech DCA Surcharge $2.00 Trade Permit Base Fee $55.00 Total Payments: $107.00 PERMIT IS APPROVED ONLY IN ACCORDANCE WITH ALL CITY OF ATLANTIC BEACH ORDINANCES AND THE FLORIDA BUILDING CODES. MECHANICAL PERMIT APPLICATION CITY OF ATLANTIC BEACH 800 Seminole Rd Atlantic Beach,FL 32233 Ph(904)247-55826 Fax(904)247-5845 JOE ADDRESS: PERMIT# PROJECT VALUE$ y\Wz,- ARI# -ll�->s'At,_Q_ l REQUIRED _Air Handling Equipment Only Air Handling Unit & Condenser _ Condenser Only NEW AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity Tons Per Unit Heat: Unit Quantity BTU's Per Unit Seer Rating Duct Systems: Total CFM REQUIRED REPLACEMENT AIR CONDITIONING & HEATING SYSTEM INSTALLATION Air Conditioning: Unit Quantity I Tons Per Unit 3 Heat: Unit Quantity 1 BTU's Per UnitSl -zs Seer Rating Duct Systems: Total CFM REQUIRED FIRE PREVENTION Fire Sprinkler System Quantity (Requires 3 sets of plans) Fire Standpipe Quantity (Requires 3 sets of plans) Underground Fire Main Value (Requires 3 sets of plans) Fire Hose Cabinets Quantity (Requires 3 sets of plans) Commercial Hoods Quantity (Requires 3 sets of plans) Fire Suppression Systems Quantity (Requires 3 sets of plans) FIRE PLACES MISCELLANEOUS: Prefabricated Fireplace QtyAutomobile Lifts Gas Piping Outlets Boilers BTU's Elevators/Escalators ALL OTHER GAS PIPING Heat Exchanger Quantity of Outlets Pumps #Vented Wall Furnaces Refrigerator Condenser BTU's #Water Heaters Solar Collection Systems Tanks(gallons) Wells OTHER: Permit becomes void if work does not commence within a six month period or work is suspended or abandoned for six months.I hereby certify that I have read this application and know the same to be true and tortes[. All provisions of laws and ordinances governing this work will be complied with whether specified or nol. The pemdt does not give authority to violate the provisions of any other state or local law regulation construction or the performant:ofcunstruction. Property Owners Namee"gN-r,. �"S7c+^r.. Phone Number-Ta. -=wme.y Mechanical Company A'• �..,.«.. Ar-.._Y. e ., Officer-P�hone233•'�i3tFax3't19'a`1'r Co.Address: �.o't 2.0St2� City- �...•clt StatcV Zip`gj,%S—� License Holder(Print): State Certification/Registration#C FBF 1�1:111e Notarized Signature gw ter+'oader � °v . r'.•7TARY Pl1a11C aN NTE OF�� foreme[his y o 201�� m1!FFt2D49k ",„fres 81412DIlf tlue ofN r is s CERTIFIED Certificate of Product Ratings AHRI Certified Reference Number: 7554647 Date: 6/1/2015 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: N4H336A(G)KF2 Indoor Unit Model Number: FEM41`36—AL Manufacturer: COMFORTMAKER Trade/Brand name: COMFORTMAKER Series name: 13 SEER N SERIES R410A HP Manufacturer responsible for the rating of this system combination is COMFORTMAKER Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity Bluth): 33600 EER Rating(Cooling): 11.00 SEER Rating(Cooling): 13.00 Heating Capadty(Btuh)@ 47 F: 33000 Region IV HSPF Rating(Heating): 7.70 Healing Capacity(Btuh)@ 17 F: 20200 'Ral bllowe!by an M.Is I')moire/¢a Mumm,need M pr"w&y puthered Gala,unless awxnpamed with a WAS.mhim IMlmtes an(moll renes DISCLAIMER MM does not endorse Me pmdud(s)listed on this Cexlflmte and makes no repreem allona,waranties or guarantee as to,and asuman no maimmaAfty for, Ne producers)listed an this Certificate.AHM expressly desdalms all liability for damages aiany kind:,Wag not of the as er penermana of the small came ne thoa,ww dmaNeatlon of data IWed on thin CexMcate.comfled ratings am wAd only 10 modex and canflnecoanm listed In the etl lredwy w .annmry ekec .org TERMS AND CONDITIONS Misfe and its contends are proprietary pmauda or AHRI.This GartmaM:nan only be used ror InelsNdual,ceaonal ane mnndomtehdarence pomades.The contents or this Garments may not,In"me or in pan,x reprodu'="c.mod,dlzsemlmted; JMR entered into a computer database;or otherwlae utilized.In any home or manner or by any means,except her the user a IndlNaual, ceaonal and confidential reieance. Al"Or amoxmq HEATING. CERTIFICATE VERIFICATION •REFWOERAnON ataTIT➢TE The lnformatlnn fa the meant meal on this cenlsaite an he v ea at www.anrimaetury.org,dick on'Verify Certificate'lints xe makelikbeneY and enter the AHM Cemfled Reference Humber and Me dale on amch the cemaate was issued, wTIM kIWetl above,ane me commotion No.,which is Need at bottom right. @2014 AlrCondltioning,Heating,and Refrigeration Institute CE ITR FICATE NO.: 13°nezesaTseoeoas