920 MAYPORT RD BUILDING COMMENTS J
11 SS OF ATLANTIC BEACH
s� 800 SEMINOLE ROAD
ATLANTIC BEACH,FL 32233
(904)247-5800
PLAN REVIEW 920 Mayport Rd. 15-COTH-990 6/03/2015
Permit Application was denied for the following:
1. Please submit original signed/sealed/dated engineering for metal building, including
foundation. Copies cannot be accepted.
2. Please submit Energy Sheets and calculations.
3. Please submit Florida Product Approval Numbers, on Product Approval Form.
4. Code Summary, on Page A0.1, states Occupancy as Building
ulin Pappears to be
mixed occupancy, Groups B and S-2 (electric motors and batteries). lease
clarify/verify.
5. Groups B and S-2 require 2-hour fire separation, per Table 508.4. Some 1-hour and
2-hour rated walls are shown; floor details are not provided. Please submit details for
occupancy separation and all fire protection/rating.
6. Please provide UL or other listing/label numbers for fire-rated assemblies.
Dan Arlington
247-5813
darlington@coab.us
1
i
i