Loading...
102 SANDY BEACH LN - ENERGY SHEETS FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Nam: TRIPLEX-UNITA Builder Name'. BEACHES HABITAT Sheet 102 SANDY BEACH LN Permit Once: CITY OF ATLANTIC BEACH City,Stale,Zip: ATLANTIC BEACH,FL,32233- Perms Number: Owner Jurisdiction: 261100 Design Locatan. FL,Jacksonville 1. New consWctior or existing New(From Plans) 9. Wall Typas(1637.3 sgft.) Insulation Area 2. Single familyor multiple family Multi-family a.Frame-Wood,Exterior R=19.0 1138.701V b.Flame-Wood,Common R=19.0 498.67 ft' 3. Number of units,9 multiple family 1 c N/A R= ft' 4. Number of Bedroom 3 1 d N/A R= fl' 10.Gelling Typea (572.0 sgfL) Insulation Area 5. Is this a worst case? No a.Under Aft(Vented) R=30.0 572.001 r 6. Conditkmed floor area above grade(fl) 1140 "'�Z b.N/A R= it- ".N/A R= FP Conditioned floor area below grade(fl) 0 11.Dude R IF 7. WnMows(130.1 sgft.) Descdpflon Area a.Sup:Auric,Rel:Attic,AH:2m!Floor 6 142 a. U-Fador: Diol,U=0.30 130.11 IF SHGC: SHGC=0.30 b. U-Factor. N/A q. 12.Cooling systems kBiwhr Efficiency a.Central Unit 24.0 SEER:15.25 SHGC c U-Fedor WA h' SHGC: 13.Heating systems y kBluBe Eificlenc d. U-Fador N/A fl' a.Electric Heat Pump 24.0 HSPF:8.70 SHGC: Area Weighted Average Overhang Depth: 3,238 IL Are.Weighted Average SHGC: 0.300 14.Hot water systems a.Electric Cap:50 gallons S Floor Types (572.0 sgft.) Insulation Area EF:4.500 a.SlatiOn-Grade Edge Insulation R=0.0 572.00 ft' b. Canservatlon feature$ b.N/A R= fl' Nona c NIA R= IF 15,Credits None Total Proposed Modified Loads: 15.18 Glass/Floor Area: 0.114 PASS Total Standard Reference Loads: 29.31 1 hereby certify that the plans and specifications covered by Review of the plans and OF THE ST.4 this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. . .....`t O PREPARED BY: J FERNANDEZ Before construction is completed DATE: 04 2015 this building will be inspected for compliance with Section 553.908 I hereby certify that this building,as designed,is in compliance Flonds Statutes. +_t� with the FloridaEn�gyC,OpE .� y� • COOWE TpJ OWNER/AGE '�^"'`g BUILDING OFFICIAL: DATE: Y'- 4F^ / DATE: - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist C; 41281201511:15 AM EnmgyGaugeO USA-FlaRes2010 Section 405.4.1 Compliant Software Page t of 5 PROJECT This: TRIPLEX-UNITA Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned!Area: 1140 Lot# Owmer Total Stores: 2 BlocWSol,Division: County Seal #of Unds: 1 Worst Case: No PlatBook: Book 108-n,page 345 Builder Name: BEACHES HABITAT Rotate Angle: 270 410 Street: 102 SANDY BEACH LN Permit OfBoe: CITY OF ATIANTIC BEACH Cross Ven5labon: No County: DUVAL Ju isdlotion: 261100 Whole House Fan: No City,State,Zip: ATI-ANTIC BEACH Family Type: Multifamily FL, 32233- New/Existing: New(From Plans) Comment: CLIMATE IECC Design Temp IM Design Temp Heading Design Daily Temp Design Location TMY Site Zona 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jackaonvllle FL_JACKSONVILLE_INT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 BWckl 1140 9120 SPACES Number Name Area Volume Kitchen Ooxrpande eedrooms Infil ID Finished Cooled Heated 1 19 Floor 588 4544 Yes 0 1 1 No Yes Yes 2 2nd Floor 572 4576 No 4 2 1 Yes Yes Yes FLOORS # Floor Type Space Fermate, R-Value Area Tib Wood Carpet iSlab-On-Grade Edge lnsulatio lid Floor 1288 0 572 If — 0 0 1 ROOF Raaf Gable Roof Solar SA Emil Emitt Deck Pilch # Typo Materials Area Area Colo Absor. Tested Tested Insul. (deg) 1 Hip Wood shingle 620 M 0 M Medium 0.98 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(I in) Area RBS IRCC 1 Ful a6ic Vented 150 572 M N , N CEILING # Coiling Type Space R-Value Ave Framing Frec Those Type 1 Under Alto(Vented) 2nd Floor 30 572M 0.11 Wood All O� G 4!28201511:15 AM EnegyGauge®USA-FuRes2010 Section 4054.1 Compliant Software Page 2 of WALLS Ad)ecent Space Cavity Wxlth Height Sheathing Framing Solar Below 1 N=>W EMedor Frame-WOW 1st Floor 19 20 0 8 0 160.0 If 0 0.125 0.7 0 _ 2 E=>N E rlor Frame-Wood let Fluor 19 31 2 8 0 249.3 M 0 0.125 0.7 0 -3 S=>E EMehor Frame-Wood let Floor 19 20 0 8 0 160.0 M 0 0.125 0.7 0 4 W=>S Neighbor Frame-Wood tat Floor 19 31 2 8 0 249.3W 0 0.125 0.7 0 -5 N=>W Exterior Frame-WOW 2nd Fluor 19 20 0 8 0 160.0 M 0 0.125 0.7 0 -6 E=>N EMerhor Frame-Wood 2nd Floor 19 31 2 8 0 249.3 M 0 0.125 0.7 0 -7 S=>E EMedor Frame-Wood 2nd Fluor 19 20 0 8 0 160.0 ft' 0 0.125 0.7 0 8 W=>S Neighbor Frame-Wood 2nd Floor 19 31 2 S 0 249.3W 0 0.125 0.7 0 DOORS # Orm Door Type Space Stomas U-Value Width Height A. Ft In Ft In 1 N=>W Insulated 19 Fluor None .46 3 8 24 k' 2 S=>E Insulated 1st Floor None .46 3 8 24 ft' WINDOWS OrieMetlun shorn is Oro aMered orientation => the ed to As Bui gilig 270 degre, / Wefi Overhang V # Omt ID F Panes NFRC -Fetter SHGC Area Depth Separation Int Shade Screening 1 NSW 1 \I Is(Clear) Yae 0.3 0.3 27.6 ft' 6 ft O in 1 It 0 in None None _ 2 E=>N 2 Vinyl Double(Clear) Yes 0. .3 10.3112 1 It O In 1 ft 0 in Nana None 3 E=>N 2 Vinyl Double(Clear) Yes 0.3 0.3 6.0 IN 1 ft O in 1 It 0 in None None _ 4 S=->E 3 Vinyl Double(Clear) Yea 0.3 0.3 4.0 IP 8 It 2 In 1 ft 0 in None None 5 N=>W 5 Vinyl Double(Clear) Yes 0.3 0.3 27.6 112 6It0 in 1ft0 in None Nona _ 6 E=>N 6 Vinyl Double(Clear) Yes 0.3 0.3 10.3 B' 1 ft 0 in 1 It O in Noire None _ 7 E=>N 6 Vinyl Double(Clear) Yes 0.3 0.3 13.3 W 1 ft 0 In 1 It 0 in None None 8 S=>E ] Vinyl Double(Clear) Yen 0.3 0.3 15.58 160 in 1ft0In Noce None 9 S=>E 7 Vinyl Double(Clear) Yes 0.3 0.3 155W 1 It 0 in 1 ft 0 in Noire None INFILTRATION # Scope Methal SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess .0005 1495.1 82.08 154.36 .474 9.8363 HEATING SYSTEM # System Tym Subtype Efficiency Capacity Block Dugs 1 Elecidc Haat Pump None HSPF:8.7 24 kBtuMr 1 eys#1 G0 4120/201511:15 AM EnergyGauge®USA-FlaRes2010 Saidon 4054.1 Compliant Software Page 3 of COOLING SYSTEM # System Type Subtype mnq dry Air Flow SHR Block Ducts 1 Central Unit None SEER:15.2524 bwTr 720 olm 0.75 1 sys#1 S. HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPrd Conservation 1 Electric Heat Pump lsl Floor 4.5 50 gall 90981 120 dog None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None fl' DUCTS J --Supply --Realm— Air CFM 25 CFM25 HVAC# # Location R-Value Area Loeatlon Area Leakage Type Handler TOT 0177 ON RLF Heat Cool _ 1 Alto 6 142 W AMc 187 K Default Leakage 2nd Fbar (Default) (Default) 1 1 TEMPERATURES Programableooling L����9JJTherm ataft:(]N ( ]1 [[X�� Calling Fans: ] IL%%J7 I%7 �LX%JJ ID(I Nc� ��XXJ7 Doc Heat'0 IN Jan lAJ Febl Mar lAJ�f LxJY lAJ Jun L+J JuWI 1X1 Aup LxJ SeP O 1 pt'Nw lX7 D Venting IN Jon lll�tl]Feb lA Mer fl>�<l7 ll�A1l Il�xl]Jun fl�All Jul lAI Aug f��All SeP TWonostat Schedule: HERS288Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 DoNing(WD) AM 78 78 78 78 78 78 78 78 80 80 8 8 PM 80 80 80 8 78 78 78 78 78 ]B 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 8 8 80 PM 80 80 80 8 78 78 78 78 78 78 78 78 Healing(WD) AM 65 65 65 65 65 65 65 8 8 88 8 8 PM 68 8 8 68 68 68 68 8 8 68 68 8 Heating(WEH) PM 68 68 68 68 68 68 68 68 8 68 68 68 61 68 C® 428/201511:15 AM EnegyGauge®USA-FlaRes2010 Section 48.4.1 Compliant Soflwara Page 4 of 5 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: 102 SANDY BEACH LN PERMIT#: ATLANTIC BEACH, FL,32233- MANDATORY REQUIREMENTS SUMMARY-See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENTS) CHECK Air leakage 402.4 To be caulked, gaskeled,weatherslripped or otherwise sealed. Recessed lighting IC-rated as meeting ASTM E 283.Windows and doors=0.30 cfmisq.ft.Testing or visual inspection required. Fireplaces: X gasketed doors&outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat& 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system.Where forced-air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental X electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts,air handlers,filter boxes and building cavities which forth the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers,shall be constructed and X sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers.Comply with efficiencies in Table 403.4.3.2.Provide switch or clearly marked circuit breaker X (electric)or shutoff(gas).Circulating system pipes insulated to=R-2 +accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics,crawlspaces,garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower(HP)of= 1 &Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor-retardant covers or a liquid cover or other means proven to reduce heat loss except if 70%of heat from site-recovered energy. Of/timer switch required. Gas heaters minimum thermal efficiency=78%(82%after 4/16/13). Heat pump pool heaters minimum COP=4.0. Cooling/hesting 403.6 Sizing calculation performed &attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system variable capacity system. Electric heat>10kW must be divid X or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. X I4/28/201511:15 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX' = 52 The lower the EnergyPerformance Index,the more efficient the home. 102 SANDY BEACH LN,ATLANTIC BEACH, FL, 32233- 1. New construction or existing New(From Plane) 9. Wall Types Insulation Area 2. Single family or multiple family Multi-family a.Frame-Wood! Exterior R=19.0 1138.70W b.Frame-Wootl,Common R=19.0 498.67 ft' 3. Number of units,if multiple family 1 c.WA R= ft' 4. Number of Bedrooms 3 d.N/A R= ft' 5. Is this a wont case? No 10.Ceiling Types Insulation Area a.Untler Aftic vented) R=30.0 572.00 ft' 6. Conditioned Poor area(W) 1140 b.N/A R= ft' 7. Windows- Descnption Area c.WA R= ft' a. U-Factor. DN,U=0.30 130.11 ft 11.Ducts R ft a.Sup:Altio.Rat:ANc,AH:2nd Floor 8 142 SHGC: BHGC=0.30 b. U-Factor, NIA ft' SHGC: 12.Coding systems kBtulhr Efficiency c. U-Factor: NIA ft' a.Central Unit 24.0 SEER:15.25 SHGC: tl. NIA SHGc: r: ft 13.Heating systema kBtumr Efficiency SHGC: a Electric Heat Pump 24.0 HSPF:8.70 Area Weighted!Average Overhang Depth: 3.338 ft. Area Weighted!Average SHGC: 0.300 8. Floor Types Insulation Area 14.Hot water systems a.Electric Cap:50 gallons a.Slab-0n-Gretle Edge Insulation R=0.0 572.00 fl EF:4.5 b.N/A R= ft c.N/A R= hit b. Conservation features None 15.Creole None I certify that this home has complied with the Florida Energy Efficiency Code for BuildingFg1iE S7-4 Construction through the above energy saving features which will be installed (or exceeded) yO _ - B in this home before final inspection. Otherwise,a new EPL Display Card will be completed based on installed Code compliant features. �y 2;'r,' :: ,•b Builder Signature: (/ ,/�'f!l Date: 5-y-, 1 Address of New Home: ioz � e[ �.c4il� PCity/FL Zip: ,�,yy,.,�,� A-• •�. 3L23� 'Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage(EEM)incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. information about the Florida Building Code, Energy Conservation,contact the Florida Building Commission' ort staff. ,�rl "Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAIg[I. EnergyGauge®USA-FlaRes2010 Section 405.4.1 Complaint Software 0 TABLE 402.4.2 I AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: TRIPLEX-UNITA Builder Name: BEACHESHABITAT Street: 102 SANDY BEACH LN Permit Once: CITY OF ATLANTIC BEACH CRY,Slate,Zip: ATLANTIC BEACH,FL.32233- Permit NumO r. Owner. Junediction: 261100 Design Locetbn: FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier Exterior thermal envelope insulation for framed walls is installed in substantial contact and continuous alignment with building envelope air barrier. Breaks or joints in the air barrier are filled or repaired. Air-permeable insulation is not used as a sealing material. Air-permeable insulation is inside of an air barrier. Ceiling/attic Air barrier in any dropped ceiling/soffit is substantially aligned with insulation and any gaps are sealed. Attic access(except unvented attic), knee wall door,or drop down stair is sealed. Walls Comers and headers are insulated. Junction of foundation and sill plate is sealed. X Windows and doors Space between window/doorjambs and framing is sealed. X Rim joists Rim joists are insulated and include an air barrier. X Floors (including Insulation is installed to maintain permanent contact with underside above-ga age and cantilevered of subfloor decking. �� floors) Air barrier is installed at any exposed edge of insulation. Crawl space walls Insulation is permanently attached to walls. Exposed earth in unvented crawl spaces is covered with Class I vapor retarder with overlapping joints taped. Shafts,penetrations Duct shafts,utility penetrations, knee walls and flue shafts opening to exterior or unconditioned space are sealed. Narrow cavities Batts in narrow cavities are cut to fit,or narrow cavities are filled by sprayed/blown insulation. Garage separation Air sealing is provided between the garage and conditioned spaces. . Recessed lighting Recessed light fixtures are air tight, IC rated,and sealed to drywall. Exception—fixtures in conditioned space. x Plumbing and wiring Insulation is placed between outside and pipes. Batt insulation is cut to fit around wiring and plumbing,or sprayed/blown insulation K extends behind piping and wiring. Shower/tub on exterior wall Showers and tubs on exterior walls have insulation and an air barrier separatino them from the exterior wall. Electrical/phone box on Air barrier extends behind boxes or air sealed-type boxes are installed. u Common wall Air barrier is installed in common wall between dwelling units p HVAC register boots HVAC register boots that penetrate building envelope ar"n. X subfloor ord all. Fireplace Fireplace walls include an air barrier. EnergyGaugeO USA-FlaRes2010 Section 405.4.1 Compliant Software wri htsoft Manual S Compliance Report Job: NABIJAX-TRIPLEX-UNIT.... 9 Date: 0212015 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 1WHILDENRD308,POMEVEORE,FL32001 Phone:B 24 9596 EmeiL FAEQENGINEER.COMNhb'.WMNNORTHFLORIONJRCOM Project Information For: BEACHES HABITAT 102 SANDY BEACH LN,ATLANTIC BEACH,FL 32233 Cooling Equipment Design Conditions Outdoor design DB: 92.0'F Sensible gain: 17999 Btuh Entering roil DB: 76.2°F Outdoor design WB: 78.0'F Latent gain: 2383 Btuh Entering coil WB: 63.2F Indoor design DB: 75.0'F Total gain: 20382 Btuh Indoor RH: 50% Estimated airflow: 800 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: CARRIER Model: 25HBC524+FX4DNF025 Actual airflow: 800 chn Sensible capacity: 11140 Btuh 62%of load Latent capacity: 2599 Btuh 109%of load Total capacity: 13739 Btuh 67%of load SHR: 81 Heating Equipment Design Conditions Outdoor design DB: 39.0°F Heat loss: 21836 Btuh Entering coil DB: 69.5'F Indoor design DB: 70.0`F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: CARRIER Model: 25HBC524+FX4DNF025 Actual airflow: 600 cfm Output capacity: 17775 Btuh 81%of load Capacity balance: 39 °F Supplemental heat required: 4061 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 800 cfrn Output capacity: 5.2 kW 81%of load Temp. rise: 0 'F The above equipment was selected in accordance with ACCA Manual S. /w® i y�r, + wrlghtsoft .rom-sunemunwwsal2o1313.o0e RSU135M I 2rN5fA'2.1 Page -4M ..ShAbhroM HVAC\HABUM-TWPLEX-UNIT-A-MJ.rvO CNc-MJ9 9u'Wkng Front naoss W epa ^- ResidentialExaminer Review Form Fonn ACC1"� • System 1 D- • • - • Equipment, 155 Mar Mar 09 Header Information Connector: FLORIDA AIR SERVICE REOUIRED ATTACHMENTS ATTACHED Manual A Form(and supporting wodslleets): Yes J§ No D Mechanical license: CAC1813923 or Ml F..*(and!applading worksheet): Yee D No D OEM performance data(heating,cooing,blower): Yes ® No D Building plan a: Manuel D Friction Rate Worksheet Yes M No D Duct distribution sketch Yes ® No ❑ Home address(Street or LOM,Block,Subdivision): 102 SANDY BEACH LN, Entire House HVAC •• • CALCULATION (IRC M1401.3) Design Conditions Rnildina Construction Information Winter Design Conditions Building Outdoor temperature: 39 °F Orientation: BuildinFmM ces West N—x Eso,Wel,5 A. Prix vast •••4 iri to Total temperature: 70 °F Total heat lass: 21838 Btuh Numbeonedbealmornsu are COMPoonetl Moor area: 1140 fP Summer Design Conditions Number of occupant: 0 Outdoor temperature: 92 °F Indoor temperature: 75 °F Windows Roo, Grains difference: 58 grAb@50 RH Eave overhang depth: 1.0 ft Sensible heat gain: 17999 Brun Internal shade: none Latent heat gain: 2383 Btuh mim.,S l...As. o , Total heat gain20382 Brun Number of skylight: 0 EQUIPMENTHVAC • 1 HPatinp Equi ment Data Cooling Equipment Data Blower Data E ulpment 3e. Split ASHP Equioment�L. x Split ASHP Healing dm: 800 4uTx., +tbu uA`l. .le. L.E do ,son Pump.&K. Cooling tan: 800 Model: CARRIER Motlel: CARRIER Sre: Nnx Ppressu :li 0 in H2O 25HBC524+FX4DNF025 25HP1 BC524+FX4DNF825 Ps..me.mmN ....u,.m.exian All Heati x.a nAm>.�utpm caWeA. ,Zi7�Btuh Total cooling capacity 13739 Brun <w.e m.,aavn a, Sensible cooling capacity: 11140 Broth Aul heating output capacity: 17782 Stahl Latent cooling capadry: 2599 Stull • 1=1 t-.ilbm Design airfiow: 800 clan Longest supply dud 377 h Duct Materials Lead Equipment design ESP: 0.50 in H2O Longest return duct: 0 fl Trunk dud: Total device pressure losses'. 0 in H2O Total effective lengln(TEL): 377 ft Available static pressure(ASP): 0.50 In H2O Friction rate: Q.fWO ingo0fl Branch dud: Round flex vinyl flit =ASP+l TEL I declare the load calculation,equipment,equipment selection and duct design yvere ngDrously Performed based on the building plan listed above. I understand the claims made on these forms will be subject to review and verification Contractor's printed name. J FERNANDEZ Contractors signature: J FERNANDEZ (E-SIGN) Date: 04/2CI Reserved for County,Town Municipality or Authority having jurisdiction use. 'Home qualifies for MA AE Form based on Abridged Edition Checklist + Wrlghtaoft Rpm-suns®u ni 201313.0.09 Rsu13ssr wrightsoftBuilding Analysis sis Job: HABIJAX-TRIPLUAINIT-... Dst•: 0=015 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HLCEN M W8,PoNIE VEDRE,FL XMH PMvre:000.82}0588 E .FMOEN01r R.COM~:YN WfrTHFLONI RLON Project Information For: BEACHES HABITAT 102 SANDY BEACH LN,ATLANTIC BEACH,FL 32233 Design Location: Indoor: Heating Cooling Jacksonville Maypon Naval,FL,US Indoor temperature(°F) 70 75 Elevation: 16 R Design TO(°F) 31 17 Latitude: 30°N Relative humidity(%) 40 50 Outdoor: Heating Cooling Moisture difference(gr8b) 15.7 58.2 Drybulb(°F) 39 92 Infiltration: Dailyrange(°F) - 15 ( 1 ) Method Simplified V*t bulb(°F) - 78 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average) Component BtuMt] Btuh %of bad Wails 2.7 1722 7.9 Glazing 48.2 11680 53.4 Doors 0 0 0 Ceilings 1.0 1131 5.2 Floors 1.3 1431 6.6 Infiltration 3.7 3304 15.1 Ducts 2587 11.8 Piping 0 0 Humidification 0 0 Ventilation 0 0 Adjustments 0 Total 218361 100.0 Component BtuINF Btuh %of load Wells 1.4 908 5.0 Glazing 46.6 11289 62.7 Doors 0 0 0 Ceilings 1.7 1983 11.0 Floors 0 0 0 Infiltration 0.8 735 4.1 Ducts 3084 17.1 Ventilation 0 0 Internal gains 0 0 Blower 0 0 _ Adjustments 0 Total 17999 100.0 Latent Cooling Load=2383 Btuh Overall U-wlue=0.182 Btuh/ff1-°F Data entries checked. �® + wrightsoftRI m- u 251&Ap 2511027 �� 0 BHW UNvxW 101]1J.O.W RSU1]581 P.,1 s\Nti9HIsaH HVAC\HABIJMTRIPLEX-11 fT .Wp C.k-MW WMW FeM Ycu: W Project Summa Job: HABUAX-TRIPLEX-UNIT-... wrightsoft n Daa: 02n015 Entire House By: JLF FLORIDA AIR SERVICE 8 ENGINEERING 150 HLDEN RD M.POWE VEORE.FL 32081 PMe.Wl0]35888 Em W:FMCENGINEERZOM Nb E:V AW WRT LORIONVR.LOM Project Information For: BEACHES HABITAT 102 SANDY BEACH LN,ATLANTIC BEACH,FL 32233 Notes: Design Information Jacksonville Maypon Naval,FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 92 °F Inside db 70 °F Inside db 75 °F Design TO 31 °F Design TO 17 °F Daily range L Relative humidity 50 % Moisture difference 58 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 19249 Btuh Structure 14915 Bluth Ducts 2587 Btuh Ducts 3084 Bluth Central vent(0 ctm) 0 Btuh Central vent(0 cfrn) 0 Bluth Humidification 0 Btuh Blower 0 Btuh Piping 0 Stun Equipment bad 21836 Btuh Use manufacturers data Rate/swing mukiplier 1.00 Infiltration Equipment sensible load 17999 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 1555 Btuh Ducts 828 Btuh Heating Cooling Central vent(0 cim) 0 Btuh Area(fl=) 1140 1140 Equipment latent load 2383 Btuh VDlume(T) 10260 10260 Air changes/hour 0.57 0.23 Equipment total load 20382 Btuh Equiv.AVF(cbn) 97 39 Req.total capacity at 0.78 SHR 1.9 ton Heating Equipment Summary Cooling Equipment Summary Make CARRIER Make CARRIER Trade 2.0 TON Trade 2.0 TON Model 25HBC524 Cond 25HBC524 AHRI ref 3645571 Coil FX4DNF025 AHRI ref 3645571 Efficiency 8.7 HSPF Efficiency 15.25 SEER Heating input Sensible cooling 18720 Btuh Heating output 24000 BbJh@47°F Latent cooling 5280 Bruin Temperature nse 27 °F Total cooling 24000 Btuh Actual air flow 800 dm Actual air flow 800 cfm Air flow factor 0.037 dm/Btuh Air flow factor 0.044 ctm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 8 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoftRi0M-OuMMDUNVM86201313e.0g Rau10 m15JMr-28111:Q:o Aft ...e\VAgMeafl XVAC\HRBIJAI(-TRIPLE%UNIT-hMJ.rvp Gk•MJ8 RwOngFmerxa•. W AED Assessment Job: HABIJAX-TRIPLEX-UN -... + wrightsoft IT Date: 0212015 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 15011ILDENRD.,GONTEVEDRE,FL32081PMne'.934e2}9590 Emil FAEGENGINEER.COMMI, W NORTHFLORIDMRCOM Project Information For: BEACHES HABITAT 102 SANDY BEACH LN,ATLANTIC BEACH, FL 32233 Design Conditions Location: Indoor: Heating Cooling Jacksonville Maypon Naval, FL, US Indoor temperature(°F) 70 75 Elevation: 16 ft Design TD(°F) 31 17 Latitude: 30°N Relative humidity(%) 40 50 Outdoor: Heating Cooling Moisture diference(grllb) 15.7 58.2 Drybulb('F) 39 92 Infiltration: Dailyrange('F) - 15 ( L ) VLABtbulb(°F) - 78 Wind speed(mph) 15.0 7.5 AdequateTest for • • H xrly Gawg ted m. 1z. 1a. e, e. z. 0 6 9 10 n tz 1) 14 is 1e 17 m 1e zo Maximum hourly glazing load exceeds average by 16.8%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh - - + wri sols-apr-zenay.zI Aft-• htso$g Ri9Mbu8�Unirenal301]1J.0.08 RSU1855c Pe9H ...fRMgMmfl HVACUNBUWX% RIPLE%-UNIT-AMJ.,up Clic=Wo Building Flmllemr. W Component Constructions Job: HABIJAX-TRIPLE%-UNIT-... wright5oft P Date: 0212915 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 1501AILOENRD308 POWEVEDRE FL32091 Phorw..900.6]35699 Emil FAECENGINEER.COMVb6'.V NJ.NORTHFLORID"R.COM Project Information For: HABIJAX-TRIPLEX-UNIT-A-MD, BEACHES HABITAT 102 SANDY BEACH LN,ATLANTIC BEACH, FL 32233 Design Conditions Indoor: Heating Cooling Jacksonville Maypon Naval, FL, US Indoor temperature(°F) 70 75 Elevation: 18 ft Design TD(°F) 31 17 Latitude: 30'N Relative humidity(%) 40 50 Outdoor: Heating Cooling Moisture difference(grAb) 15.7 58.2 Drybulb('F) 39 92 Infiltration: Dailyrsnge CF) - 15 ( L ) Method Simplified Wetbulb(°F) - 78 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or AnaU-value Insul R the HTM Loss Clg HTM Gain a &W,6R'F R. .BNi 9AM aw, ami BM Walls 1213-21aw:Fm wall,brk 4"ext,r-11 ow ins,2"x4"wood fvn,r-2 int bol n 624 0.086 13.0 2.67 1664 1.41 877 ins a 45 0.006 13.0 2.67 120 1.41 63 all 669 0.006 13.0 2.67 1784 141 941 Partitions (none) Windows 10AHn:1 glazing,relbdive(114-only)glz,and no brk frn mal,114"thk, n 84 1.670 0 51.8 4349 27.6 2316 high rlld pert:8 it overhang 18 A window M.6 ft sep.) 1Aclom:1 gbzing,di-glz,art no brk hm mat,VB"lhk:1%overhang 16 a 35 1.270 0 394 1378 93.5 3273 d window M,2 R wp.) Doors (none) Ceilings 16B-30ad:Attic ceiling,asphalt shingles root mat,r-31 root ins,r-30 wit n 1140 0.032 30.0 0.99 1131 1.74 1983 ins Floors 22A-Wh:Bg floor,heavy damp soil,on grade depth,vinyl flr lnsh n 34 1.358 0 42.1 1431 0 0 A 4/ Y wri htsoI9 hLSUIA Unlver¢ 1201313.0.0R5U135& MISA,-2611.U42 Pagel ...\Mgh"HVACWABUJP RIFLEX-UNIT MJ2.mp CYc=MJ8 auMln9Fmntlece¢: W Component Constructions Job: HABIJAX-TRIPLEX-UNIT... wrightsOR P Date: 02/2015 BATH2 By: JLF FLORIDA AIR SERVICE & ENGINEERING 1W HILDEN RD 308,PO WE Y ORE.FL 32W1 Phom 50F823569a EmaII.FBEQENGINEER COM Web WrWJ.NORTHFLORIDMR.COM Project Information For: HABIJAX-TRIPLEX-UNIT-A-MD, BEACHES HABITAT 102 SANDY BEACH LN,ATLANTIC BEACH, FL 32233 Design Location: Indoor: Heating Cooling Jacksonville Maryport Naval, FL, US Indoor temperature(°F) 70 75 Elevation: 16 R Design TD (`F) 31 17 Latitude: 30`N Relative humidity(%) 40 50 Outdoor: Heating Cooling Moisture diference(9r/Ib) 15.7 58.2 Dry bulb('F) 39 92 Infiltration: Dailymnge(°F) - 15 ( L ) Method Simplified Wet bulb('F) - 78 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Ana U-value Insul R Htg HTM Loss Clg HTM Gal. R aN.M'F s' 69in BbnT' aM Walls (none) Partitions (none) Windows 10A-m:1 glazing,reflective(1/4 only)glz,mg no brk hm mat.1/4"thk, n 6 1.670 0 51.8 311 27.6 165 high Mot pert;8 B overhang(8 R wages,ht,6 R esp.) Doors (none) Ceilings 16B-30ad Attic ceiling,asphalt shingles roof mat,r-31 roof ins,r-30 tail n 72 0.032 30.0 0.99 71 1.74 125 ins Floors 22A-vph:Bg floor,heavy damp soil,on grade depth,nnyl flr lnsh n 6 1.358 0 42.1 253 0 0 Wrightsoft Rig ht-SuileA U nrvxaN 2013 13.0.09 RSLI 3554 2015-hpr-281 PW42 �� ..khtsMHVAC JP -TRIPLU-UNITA-MJ2.mP Cak•NUS lmsing Frmlf•ma: W Page 1 Com onent Constructions Job: HABIJAX-TRIPLEX-UNIT-... wrightSOft P Date: 0212015 MBED By: JLF FLORIDA AIR SERVICE & ENGINEERING 1 W HILMN RD 309.PDNTE VEDRE FL 32081 Phone.90402198¢3 Einal FAEOENGINEERCOM Web'.NMNJNORTHFLORIDN ROOM Project Information For: HABIJAX-TRIPLEX-UNIT-A-MD, BEACHES HABITAT 102 SANDY BEACH LN,ATLANTIC BEACH, FL 32233 Design Location: Indoor: Heatinng Cooling Jacksonville Maypon Naval,FL,US Indoor temperature(°F) Elevation: 16 ft Design TD(°F) 31 17 LatBude: 30°N Relative humidity 1%) 40 50 Outdoor: Heating Cooling Moisture difference(grAb) 15.7 58.2 Drybulb(eF) 39 92 Infiltration: Dailyrange CF) - 15 ( L ) Method Simplified Wetbullaff) - 78 Constmction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or AreaT U-value Insul R His HTM Loss Clg HTM Gain AI,M'F R-'FiIDn BLIM BWe 01IUT' BM Walls 12B-2bw:F.wall,brk 4-See r-11 cavils,2"X4-wood him,r-2 int btl n 110 0.086 13.0 2A7 293 1.41 155 Ina Partitions (none) Windows 1 OAHn:1 glazing,reBedeve(114"only)g12,hill no brc firm mat.114"ink, n 32 1.670 0 51.8 1657 27.6 882 high Mrs pert;8 I overhang(8 it window IS,6 it sep.) Doors (none) Ceilings 1613-30ad:Attic ceiling,aspha8 shingles root mat,r-31 real Ins,r-30 wit n 181 0.032 30.0 0 89 180 1.74 315 ins Floors (none) 201 S-s r-2a 1138:42 wrightsoft Ril11-S.R.U niverea120131se as RSU135N Prye3 M ,RhtighI HVACWPBIJA -TRIPLE%-UNIT-A-MJ2.np Gk=Wil Building FronlramsW + wrightsoft Component Constructions Uau O�'AX'TRIPLEX-UNIT... BED2 By: JLF FLORIDA AIR SERVICE & ENGINEERING 150HILDEN RD We PONIEVEDRE.FL33041 PMne:9018231x496 OWN:FAECENGINEER.COM Wep:W NORTHFLORIDMR LOM Project Information For: HABIJAX-TRIPLEX-UNIT-A-MD,BEACHES HABITAT 102 SANDY BEACH LN,ATLANTIC BEACH,FL 32233 Design Location: Indoor: Heating Cooling Jacksonville Mayport Naval, FL,US Indoor temperature(°F) 70 75 Elevation: 16 It Design TD ff) 31 17 Latitude: 30% Relative humidity(%) 40 50 Outdoor: Heating Cooling Moisture difference(grAb) 15.7 58.2 Drybulb('F) 39 92 Infiltration: Dailyrange(°F) - 15 ( L ) Method Simplified V,btbulb CF) - 78 Construction quality Average Wend speed(mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss Cie HTM Gain m e M'F x.'1,11. Nuh Walls 1213-2bw.Fm wall,brk 4"ext r-11 cav ins,2"x4"wood Irm,r-2 int bd n 126 0,086 13 0 2,67 336 141 177 ins Partitions (none) Windows 10A-m:1 glazing,Detective(1/4'only)gh,me no brk Lin mat,1/4'Irk, n 16 1.670 0 51.8 828 27.6 441 high Md pert;8 fl overhang(8 8 window ht,6 a sop.) Doors (none) Ceilings 163-30ad'.ABic ceiling,asphah shingles roof mat,r-31 roof ins,r-30 ceil n 171 0.032 30.0 D.99 170 114 297 Ins Floors (none) 1. l wri htl6i 201sJy-21111:38:42 9 RIpMEUXs9UNvxW 101313.0 GH R5U105:M Pye4 ..WWkgMeMNJFCW .tAX-TRPLEx-UHT- MJ2.mp Gk•MJB BuilEin9 Fronneces'. W Component Constructions Job: HABIJA(-TRIPLE%-UNIT-... wrightsoft P pate: 0212615 GREAT By: JLF FLORIDA AIR SERVICE & ENGINEERING 150HILDENRD" RONTEVEDRE FL320B1PMne'.6048235698 EMQ,FAE@ENGINEER.COMVJeb'.WrWJ.NORTHFLORIOMIR,COM sees Project Information For: HABIJAX-TRIPLEX-UNIT-A-MD, BEACHES HABITAT 102 SANDY BEACH LN,ATLANTIC BEACH,FL 32233 Design Location: Indoor: Heating Cooling Jacksonville Maypon Naval, FL, US Indoor temperature(°) 70 75 Elevation: 16 R Design TD(°) 31 17 Latitude: 30°N Relative humidity(%) 40 50 Outdoor: Heating Cooling Moisture i ifference(gr1b) 15.7 58.2 Drybulb('F) 39 92 Infiltration: Dailyrange CF) - 15 ( L ) Method Simplified Wat bulb('F) - 78 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U-value Insul R Hilt HTM Loss Clg HTM Gain rc arJr 'F rt-F,e.e Bram• awn mngr aen Walls 12B-2bw:Fm wall.sk 4-ext,r-11 cav ins,2'x4"wood rrm,r-2 int bd n 111 0.086 13.0 2.67 296 1.41 156 ins a 45 0.086 13.0 2.67 120 1.41 63 all 1% 0,086 13.0 2.67 416 1.41 219 Partitions (none) Windows 1A-clam1 glazing,or glz,mtl no bill,arm mat,118'thk;1 8 overhang(6 a 35 1.270 0 39.4 1378 93.5 3273 fl window ht,2 of sap.) Doors (none) Callings 168-30ad.At50 ceding,asphalt shingles root met,r-31 root ins,00 cell n 255 0.032 30.0 0 99 253 1.74 M3 ins Floors 22A-vph:Bg floor,heavy damp soil,on grade depth,vinyl fir fnsh n 12 1.358 0 42.1 505 0 0 .1 s-Ppr-2911'.3842 wrightsoft Right-Buses u nw•rsal 201313a.o6 RSU13654 Pages ..AWighlwll HVACV lJAx-TRIPIf UNIT-A-MJ2.mp C•lo=MJB Buli ing Fmnlleu W Component Constructions Job: HABIJAX-TRIPUF -UNIT wrightsoft By: 0=015 MWIC y FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 309,PONTE VEDRE FL 32081 Prime:W 21%% Em iI.FAEOENGINEERCOM Web'.WAW.NORTHFLORQ"R.CDM For: HABIJAX-TRIPLEX-UNIT-A-MD,BEACHES HABITAT 102 SANDY BEACH LN,ATLANTIC BEACH,FL 32233 Design Location: Indoor: Heating Cooling Jacksonville Maypon Naval,FL,US Indoor temperature ('F) 70 75 Elevation: 16 R Design TD CF) 31 17 Latitude: 30°N Relative humidity(%) 40 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 15.7 58.2 Drybulb(°F) 39 92 Infiltration: Daily range(°F) - 15 ( L ) Method Simplified Watbulb("F) - 78 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U-value Inset R Hill,HTM Loss Cie HTM Gain m swM�•F r-'Feu, e.n.m awn smm• a�n Walls 12B-2bw:Fm wall,bilk 4"ext.Ill 6av ins,2'x4"wood Mn,r-2 int bd n 9 0.086 13.0 2.67 24 1.41 13 ins Partitions (none) Windows (none) Doors (none) Ceilings 16B-30ad Able ceiling,asphalt shingles mot not,131 root ins,r-30 cell n 32 0.032 30.0 0.99 32 1.74 56 ins Floors 22A-vph:Bg floor,heavy damp soil,on grade depth,vinyl fir Msh n 8 1.358 0 42.1 337 0 0 k�r i4F2015-4,28 11 wrighls011t RIM-SUIIaw Un—el 201313 sea RSU135A Pepe 6.,6 ..\NRIMadI HJACWla1JAC-TRIPLE%-UNITA-MJ2 rip Cale=MJB BWInO Fmnl larva: W Component Constructions Job: HABIJAX-TRIPLEX-UNIT-... wright5oft P Date: 0212015 BATHI By: JLF FLORIDA AIR SERVICE & ENGINEERING 1WHILBENRD888,PONIEWDRE.FL32081 Fnana:9048239889 EmNI'.FAECENGINEER.COMwal, NNWV.NORTIFLORIBa01RCOM Project Information For: HABIJAX-TRIPLEX-UNIT-A-MD,BEACHES HABITAT 102 SANDY BEACH LN,ATLANTIC BEACH,FL 32233 Design Conditions Location: Indoor: Heating Cooling Jacksonville Maryport Naval, FL,US Indoor temperature(°F) 70 75 Elevation: 15 8 Design TD CF) 31 17 Latitude: 30°14 Relative humidity(%) 40 50 Outdoor: Heating Cooling Moisture difference(grAb) 15.7 58.2 Drybulb(°F) 39 92 Infiltration: Dailyrenge CH - 15 ( L ) Method Simplified Nkt bulb(°F) - 78 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U-value Ingot R Nig NTM Loss. CIB HIM Gain a glmM-F T.. sm. gain Wnm .1 Walls 12B-2bw:Fm wall,blk 4-isd,r-11 cav ins,TX4"mod firm,r-2 int bd n 6 0.086 13.0 2.67 16 1.41 8 ins Partitions (node) Windows (node) Doors (none) Callings 166-308d'.Agic Ceiling,espheR shingles roof mat,r-31 roof Ins,r-30 Ceil in 52 0.032 30.0 0.99 52 1.74 90 Ins Floors (none) c1� y1 wrightSOft' Rig N-Su me U NvwuI"1313oW RSU13558 201641-2811138:42 i^] ..\WlphNdI HVAL1-NBIJAX-TRIPLEX-UNIT-FMJ2.rvp Lek•MJ0 BWNInpFort lxm: W Component Constructions Job: HABIJAX-TRIPLEX-UNIT-... Wrightsoft p Dale: 02n015 MECH By: JLF FLORIDA AIR SERVICE & ENGINEERING IWHILMNM".PON WME,FL32NIPI :BD0.92Y N Eines:FPECENGINEER.COMNbb'.OWKNORTHFLORIDAUN Project Information For: HABIJAX-TRIPLEX-UNIT-A-MD, BEACHES HABITAT 102 SANDY BEACH LN,ATLANTIC BEACH,FL 32233 Design Conditions Location: Indoor: Heating Cooling Jacksonville Maypon Naval, FL,US Indoor temperature CF) 70 75 Elevation: 18 It Design TD(°F) 31 17 Latitude: 30°N Relative humidity(Y4) 40 50 Outdoor: Heating Cooling Moisture diference(grflb) 15.7 58.2 Drybulb(°F) 39 92 Infiltration: Dailyrange CF) - 15 ( L ) Method Simplified Watbulb('F) - 78 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area Oaalus Insul R His HTM Loss Clg HW Gain If BAM-'F IM1'F.BIi Bath BWI, BMnP BM Walls 12B-2bwFrm wall,ink 4"ext r-11 cav ins,2"x4"wood trm.r-2 tnt bd n 8 0.086 13.0 2.67 21 1.41 11 ins Partitions (none) Windows (none) Doors (none) Ceilings 16B-308d:Aaic calling,asphalt shingles and mel,r-31 root ins,v30 mil n 48 0.032 30.0 0.99 48 1.74 83 ins Floors 22A-vp1:as floor,heavy damp soil,on grade depth,vinyl fir thsh n 8 1.358 0 42.1 337 0 0 A1SAp-2B ll:b:12 WriOtSO t' RIpMSUH•O GrNerW 30111].0.W RSMI3SH Ppa ...1yaIy�NW HVACUNBIlA1t-1PoPlEX41MT-M.142.rvp CYc.MJO BWNnpFmnM1uc W Component Constructions Job: HABIJAX-TRIPLIJ-UNIT-... + wrightsoft Data: 028015 BED3 By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308.PONTE VEDRE,FL 32081 PM1me-.Ws-u1 smvs Emml'.FPE®ENGINEER,COM Mb'.VhWIN0RTHFLv4[v RR COM Project Information For: HABIJAX-TRIPLEX-UNIT-A-MD, BEACHES HABITAT 102 SANDY BEACH LN,ATLANTIC BEACH,FL 32233 Design Location: Indoor: Heating Cooling Jacksonville Maypon Naval, FL,US Indoor temperature(°F) 70 75 Elevation: 16 It Design TD(°F) 31 17 Latitude: 30°N Relative humidity(%) 40 50 Outdoor: Heating Cooling Moisture difference(grAb) 15.7 58.2 Drybulb(°F) 39 92 Infiltration: Dailymnge ff) - 15 ( L ) Method Simplified Wet bulb(1) - 78 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area Uwalue bleat R Htg HTM Loss Cls HTM Gain rc ash's W--Frew, sunr awn al mh Walls 1213-21bw:I'm wall,blk 4-ext,r-11 cav ins,2'X4"wood Inn,r-2 int bd n 127 0.086 13.0 2.87 339 1.41 179 ins Partitions (none) Windows 10A-m'.1 glazing,refiedhie(1/4'only)g2,mtl no talk Inn mat, 1l4"Ihk, n 15 1.670 0 51.0 777 27.3 414 high rfld pert;8 fl overhalq(a It window ht.6 fl sep.) Doors (none) Ceilings 16B-30ad:Agic ceiling,asphalt shingles mol mal,r-31 root ins,r-30 Deal n 151 0.032 30.0 0.99 150 1.74 263 ins Floors (none) G® F Wrightsoft R18n1.suaeA Universal M13 13D.09 Rsu135A 2msiyr3H 9 P Pq• ..\VFgM11saII HVALWABIJPX-TRIPLEX-UNITAMJ2 mp LeI—MJB BUIMIno FmnlleusW CompConstructions Job: HABIJA%-TRIPLE%-UNIT wrightsoft Y Date: 0212015 KITCHEN By: JLF FLORIDA AIR SERVICE & ENGINEERING 150HILDENROMB.PONTEV DRE FL32081Phone:W 29 9906 Emall'.rmill,EWINEER.COMWeb WVNJ.NORTHFLORWMRLOM Project Information For: HABIJAX-TRIPLEX-UNIT-A-MD, BEACHES HABITAT 102 SANDY BEACH LN,ATLANTIC BEACH, FL 32233 Design Location: Indoor: Heating Cooling Jacksonville Maypon Naval, FL, US Indoor temperature(°F) 70 75 Elevation: 16 It Design TD ('F) 31 17 Latitude: 30°N Relative humidity 1%) 40 50 Outdoor: Heating Cooling Moisture difference(9r/Ib) 15.7 58.2 Drybulb(°F) 39 92 Infiltration: Dailyrange CF) - 15 ( L ) Method Simplified Wet bulb('F) - 78 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area ti-value InsulR Htg HTM Loss Cis HTM Gain m aM, F Ir.Freon aenm ae,n aenm aun Walls 12B-2bw:FM wall,brk 4'ext,r-11 cav ins.Tx4"wood Mn,r-2 int bd n 127 0.086 13.0 2s7 339 1 Al 179 ins Partitions (none) Windows 10A-m'.1 glazing,reflective(1/4'only)glz,mtl no brk hm mat,1/4"Mk, n 15 1.670 0 51.8 777 27.6 414 high do pert,8 I overhang(8 It window M,6 fl sep.) Doors (none) Ceilings 16B-30adAttic ceiling,asphalt shingles roof mat,r-31 roof ins,r-30 cell n 178 0.032 30.0 0,99 177 1.74 310 ins Floors (none) 2015-A 2e 11:M42 wrightsoft RI9 M-S.reO um«..1201313.0 o9 Rsu1154 Pey 10 .JV`tiOMeM HVFLWA&JN-TRIPLE%-UNIT-hlAJ2.mp GIc=MJ9 BUMEIn0 Fron11ewe: W Duct System Summary Job: HABIJA%-TRIPLEX-UNIT-... W ri Pub$oft Date: 0212015 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 15QHILDENRD309.P0NTEVEDRE.FLUW1PMne:W4@9-BBBB Em .FMaENGINEER.COMVft WNVV.NORT*LOWDMR.COM Project Information For: HABIJAX-TRIPLEX-UNIT-A-MD,BEACHES HABITAT 102 SANDY BEACH LN,ATLANTIC BEACH,FL 32233 Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O Lowest friction rate 0.500 iN100fl 0.500 in/100fl Actual air flow 800 cfm 800 clan Total effective length(TEL) 377 6 SupplyDetail Table Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cim) (DIM) FR (in) (n) Mao Ln(R) Ln(it) Trunk MECH In 541 28 10 0.500 4.0 0x0 VIFx 307.0 70.0 BATH2 In 813 41 29 0.500 4.0 0x0 VIFx 307.0 70.0 MBED In 3360 171 145 0.500 7.0 0x0 VIFx 307.0 70.0 BED3 In 2293 117 97 0.500 6.0 0x0 VIFx 307.0 70.0 WCHEN In 2326 118 101 D.500 6.0 0x0 VIFx 307.0 70.0 BED2 In 2378 121 103 0.500 6.0 Oxo We 307.0 70.0 GRFAT C 2152 85 149 0.500 6.0 Oxo VIFx 307.0 70.0 DREAT.A c 2152 85 149 0.500 6.0 Oxo VIFx 307.0 70.0 BATH1 c 148 6 10 0.500 4.0 Oxo VIFx 307.0 70.0 Mwc It 530 27 8 0.500 4.0 Oxo VIFx 307.0 70.0 C; w htsoft 2019Mr-]811:1):24 rLB� RgM£uBea UNvxaN 2013190.09 R9V19554 Paa1 ...�.teiEDOCMABIJA-TRIPUEXLUNIT MD.w Gk=Mb BAfinBF-ttaws: W CERTIFIED Certificate of Product Ratings AHRI Certified Reference Number: 3845571 Date: 4/27/2015 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 25HBC524Afe30 Indoor Unit Model Number: FX40NF025 Manufacturer: CARRIER AIR CONDITIONING Trade/Brand name: CARRIER Series name: COMFORT 13 PURON HP Manufacturer responsible for the rating of this system combination is CARRIER AIR CONDITIONING Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRlsponsored, independent,third party testing: Cooling Capacity(Btuh): 24000 EER Rating(Cooling): 12.00' SEER Rating (Cooling): 15.25 Heating Capacity(Btuh)@ 47 F: 24000 Region IV HSPF Rating(Heating): 8.70 Heating Capacity(Btuh)@ 17 F: 14700 Four,holbwad by an am...w I') ni cate a mmontary metre of pmmiovdy pubscomc care,enleee accompamed atlM a WaS,vmkn Indicate:an mvolunlar,name DISCLAIMER e''w''_l AHRI does not anyone the accruals)listed on this Certificate and makes no mpreaentallms,warranties or guarantees as to,and assumes no mspppM01ID r the presents)listed on this Certificate.AHRI addreWy disclaims all liability for damages of any kind ending am of me use or peMrmance 0)tIITM1UY[RN,or the unauthorized accurate of data listed On Ws CertMcale.Contend ratings are valld only Mr models and configurations listed In the directory at wwwsNldlrectory.org. D S TERMANCONDITIONS TERMS AND and its contents are proprietary products of Asia.This Certificate aM1all on"used for Individual,personaland confidential reference purposes.The contents of this CeNficah may not,in wMle or In Dart,be reproduced;ended dladdm lab le k JUR entered Into a computer database;Or otherwise Wllxed,In any farm or manner or by any means,brand for Ne user's Individual, pl moral and confidential reference. AIRLONOnI ONING.HFATINO, CERTIFICATE VERIFICATION G REFRIGERATION INSTITUTE The Information tar Ne model eked on this[edifi[atecan be verified M www.eMldlrectory.org,click on'Verby Certificate'link Ha id,k'n", and enter Ne AHRI Certified Reference Number and Me date on which the[edMcade was Issued, whlch is listed arum,and the CertMLMd No.."Ith is listed M bottom tlgllt -- - — — _ _ - 02014 Air-Conditioning,Heating.and Refrigeration Institute CERTIFICATE NO.: 13oTbstatRtstDReoe IRR91 4 A/C PATIO 6AWWM m U ui PAM Ofi6 T ® ® Too ;:. KIIGIEtl KITCHM IT &x on. Y°n 6dN Y N Y m IOMMB a an IY FE�1 MRI 13' C O I6M2O � 16MN �Gy NEG IWO IOM69 I]' IT IOX6X6 GREAT ROW CARe T¢nOCM peW GREAT ROW low" 'olm 10.V66 'RCNT PORCH Toy ;oi ioi i4 ioi i4 FRONT GORCH of VNIT 'g uruIB UNIT 't_ BEACHES HABITAT 0 102-106-110 SANDY BEACH LN ATLANTIC BEACH, FL 32233 TRIPLEX MECHANICAL PLAN - M1 aEDROOM BEDROOM eEDROM f2 BMRWM� 9EDROOM e92 Ll IGX6%6 long a IUX�R6 ��nu 12 long 10%6M8 IGMI(6 20 � 0 a 1210 10� I� nI�2xIU I2xl Y a Bvdxd BAIIROOM '6 MOM 1T 12 rl 6!x1 TG a BA41R40d Iia1O iG 12x10 12001240 1217 ixY! MASTER 10 6X6 MASTER 6xL! BEDROOM MASTER BEDROOM fi ncrt a ¢u BEDROG! y�, [Inco UNIT ,A' UNIT ,B, UNIT(,_ BEACHES HABITAT GO 102-106-110 SANDY BEACH LN ATLANTIC BEACH, FL 32233 TRIPLEX MECHANICAL PLAN - M2