110 SANDY BEACH LN - ENERGY SHEETSFORM 405-10
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: TRIPLEX -UNIT -C _�
Builder Name: BEACHES HABITAT
Street: 110 SANDY BEACH LN
Permit Office: CITY OF ATLANTIC BEACH
City, State, Zip: ATLANTIC BEACH, FL, 32233-
Permit Number:
Owner:
Jurisdiction: 261100
Design Location. FL, Jacksonville
1. New construction or existing New(Fmm Plans)
9. Wall Types (1637.3 sgft.)
Insulation Area
a. Frame - Woad, Exterior
R=19.0 1138.70/N
2. Single family or multiple family Multi -/amity
b. Frame - Wood, Common
R=19.0 498.67 ft
3. Number of units, 9 multiple family 1
c. WA
R= ft'
4. Number of Bedrooms 3
d. N/A
10. Ceiling Types (572.0 sgft.)
R= fl'
InsukWon Area
5. Is this a worst cess? No
a. Under Attk (Vented)
R=30.0 572.00 ft
6. Conditioned floor area above grace (W) 1140
b. NIA
R= R
W
c. NIA
R=
Conditioned floor area below, grade (W) a
11. Ducts
R fe
7. Windowe(130.1 sgft.) Description Area
a. Sup: Mio, Ret: Alec, AH: 2nd Floor
6 142
a. U -Factor, Dbl, U=0.30 130.11 ft
SHGC: SHGC=0.30
12. Cooling systems
kBtugtr Efficiency
b. U-Facbc N/A
a. Cental Unit
24.0 SEER:15.25
SHGC:
c. U -Factor. WA fl'
SHGC:
13. Heading systems
kBtuMr Efficiency
d. U -Factor: N/A IF
a. Electric Heat Pump
24.0 HSPF:8.70
SHGC:
Area Weighted Average Overhang DepM: 3.338 ft.
Area Weighted Average SHGC: 0.300
14. Hol water systems
a. Electric
Cap: 50 gallons
8. Floor Types (572.0 sqT) Insulation Area
EF: 4.500
a. Slab -On -Grade Edge Insulation R=0 0 572.00 ft'
b. Conservation features
b. NIA R= ft'
None
c. N/A R= ft'
15. Credits
None
Total Proposed Modified Loads: 15.18
PASS
Glass/Floor Area: 0.114 Total Standard Reference Loads: 29.31
I hereby certify that the plans and specifications covered by
Review of the plans and
O* -V E ST4
this calculation are in compliance with the Florida Energy
specifications covered by thisI�
=
Code
calculation indicates compliance
yam' //,"
with the Florida Energy Code.
(. n O
PREPARED BY: J FERNANDEZ
Before construction is completed
al C
DATE: 04 2015
this building will be inspected for
compliance with Section 553.908
a7 a
•COO
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
WE'CQ'
OWNER/AGENT:
BUILDING OFFICIAL:
4E-�
DATE'.
DATE: )�-[1 - -
Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist
G;
4/2812015 11'54 AM EnergyGauge® USA - FlaRes20lO SKUw 4054.1 Compliant Software Page t of 5
4/281201511:54 AM EnegyGaugeOUSA- FlaResnl(l Section405.4.1 Compliant Software Page 2 of
PROJECT
We:
Building Type:
Owner:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
TRIPLEX-UNITC
User
1
BEACHES HABITAT
CITY OF ATLANTIC BEACH
261100
Multifamily
New (From Plans)
Bedrooms: 3
Conditioned! Area: 1140
Total Stories: 2
Worst Case: No
Rotate Angle: 270
Cross Ventilation: No
Whole House Fan: No
Address Type:
Lot#
Bbck/SubDivision:
PlalBook:
Street:
County:
City, State, Zip:
Street Address
County Seal
Book 108-n, page 345
110 SANDY BEACH LN
DUVAL
ATLANTIC BEACH,
FL, 32233-
CLIMATE
/
v Design Location TINY Site
IECC Design Temp
Zara 97.5% 2.5%
Int Design Tamp Heading Design Deily Temp
Winter Summer Degree Days MolsWre Range
FL,
Jacksonville FL_JACKSONVILLE INT 2 32 93
70
75 1281
49 Medium
BLOCKS
Number
Name Area
Volume
1
Bbck1 1140
9120
SPACES
Number
Name Area
Volume Kitchen Occupants
Bedrooms
InftI ID Finished Cooled Heated
1
2
19 Floor 566
2nd Floor 572
4544 Vee 0
4576 No 4
1
2
1 No
1 Yes
Vee Yes
Yes Yes
FLOORS
#
Floor Type Space
Peameater R -Value
Area
Tib Wood Comet
1 Slab -On -Grade Edge Insulatio 1st Floor 126 If 0
5726'
__
0 0 1
ROOF
#
Type Materiels
Roof Gable Roof
Area Arne Cola
Solar
Absor.
SA Emit Emig Deck Pitch
Tested Tested Insul. (deg)
1
Hip Woad shingle
620 ft' OM Medium
0.98
No 0.9
No 0 22.6
ATTIC
v#
Type Ventilation Vent Ratio (11 in)
Area
RBS IRCC
1
Full attic Vented! 150
572W
N N
CEILING
#
Coiling Type
Space R -Value Area
Framing Frac
Truro Type
1
Under Attic (Vented)
2nd Floor 30 572 ft
0.11
Wood
4/281201511:54 AM EnegyGaugeOUSA- FlaResnl(l Section405.4.1 Compliant Software Page 2 of
4!28201511:54 AM EnergyGauge® USA- FlaRes2010 Section 405.4.1 Compliant SoIN are Page 3 of 5
WALLS
Atlfeoent
Cavity Willh
Height
Shre.eathing
Fremkg Sdar
B
W.H Type
SPsm
�elow
Ft
I.
1
Tn
N=>W Exterior.
Forma - Wood
1st Floor
19 20
0
8 0
160.Ofl
0
0.125 0.7
0
E=>N Exterior
Frame - Wow
let Floor
19 31
2
8 0
249.3 W
0
0.125 0.7
0
-2
3
S=>E Exterior
Forme - Wow!
Ist Floor
19 Al
0
8 0
160.0 ft'
0
0.125 0.7
0
W=>8 Neighbor
Frame - Wootl
1st Floor
19 31
2
8 0
249.3 IF
0
0.125 0.7
0
-4
5
N=>W Extend
Frame - Wool
2nd Floor
19 20
0
8 0
180.08'
0
0.125 0.7
0
E=NJ Exterior
Frame - Waal
2nd Floor
19 31
2
8 0
249.3 W
0
0.125 0.7
0
-6
S=>E Exterior
Frame - Wool
2nd Floor
19 20
0
8 0
160.0 IF
0
0.125 O]
0
-7
8
W=>S Neighbor
Frame - wow
2nd Floor
19 31
2
8 0
249.3W
0
0.125 0.7
0
DOORS
is OrM
Door Type
Space
Storms
U -Value
Width
Nee
F
In
FtIn
1 N=>W
Insulated
19 Floor
None
.46
3
8
248
_
2 S=>E
Insulated
1st Floor
None
46
3
8
248'
WINDOWS
Orientation shown is the entered orientation (=>I ohanoed
to As Built rotated 270 usurious).
/
Wall
Overhang
V
# Omt ID Frame Panes
NFRC
U-Famir SHGC
Area
Depth
Western
IM Shad.
Screening
1 N=>W 1
Vinyl Double (Clear)
Yes
0.3 0.3
27.68'
680 in
180 in
None
None
2 E=>N 2
Vinyl Double (Clear)
Yes
0.3 0.3
10.38'
180 in
i80 in
Nona
None
_
3 E=>N 2
Vinyl Double (Clear)
Yes
0.3 0.3
6.0 If
1 ft 0 in
1 ft 01n
None
None
4 S=>E 3
Vinyl Double (Clear)
Yes
0.3 0.3
4.08'
8 I 21n
1It0 in
None
None
5 N=>W 5
Vinyl Double (Clear)
Yes
0.3 0.3
27.68'
6It0 in
1ft0 in
Noor
None
6 E=>N 6
Vinyl Double (Clear)
Yes
0.3 0.3
10.3 ft'
180 in
1ft01n
None
None
7 E=>N 6
Vinyl Double (Clear)
Yes
0.3 0.3
13.3 8
1 ft 0 In
i 8 0 in
None
None
_
8 S=>E 7
Vinyl Double (Clear)
Yes
0.3 0.3
15.581
ft01n
1ft0 in
None
None
9 S=>E 7
Vinyl Double (Clear)
Yes
0.3 0.3
15.5 ft'
1 It 0 in
1 It 0 I
None
None
INFILTRATION
#
SPOPe Method
SLA CFM 50 EU
EgLA
ACH
ACH 50
1 Wholehouse Best Guess
.0005
1495.1 8208
154.36
.474
9.8363
HEATING SYSTEM
# System Type
Subtype
Efficiency
Capacity
Block
Duds
1 Electric Heat Pump
None
HSPF: 8.7 24 kBUNmr
1
sys#1
4!28201511:54 AM EnergyGauge® USA- FlaRes2010 Section 405.4.1 Compliant SoIN are Page 3 of 5
4/2&201511:54 AM EnergyGauge® USA - FlaRes2010 SxBDn 405.4.1 Compliant SoBware Page 4 of 5
COOLING SYSTEM
# Syetem Type
Subtype
Efficiency
Capacity
Air Flout
SHR
Block
Duds
1 cerebral Unit
None
SEER: 15.2524 kBtu#rr
720 cfrn
0.75
1
sys#1
HOT WATER SYSTEM
It System Type
SubType
Location
EF Cap
Use
Setpnt
Gonserva4on
1 Eleobic
Heat Pump
ist Floor
4.5 50 gal
90 gal
120 Jog
None
_
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Carl# Company Name
System Martel# Collector Model
III Area
Volum
FEF
None None
8
DUCTS
/ —Supply --
Retain
Air
CFM 25
CFM25
HVAC#
V # location R -Value
Area
Location
Area Leakage Type
HeMler
TOT
OUT
ON
RLF
Haat Cool
1 Attic
6 142 M
Attic
187 IF Default Leakage
2rq Floor
(Default) (Dell
1 1
TEMPERATURES
ProgiamabljeeXcooling(Thenimtott((IN
Cr0eiilling Fans:
Feb�DX(lj
Has
eiitirg M Feb
Mar
DD(Dl
X M �Ll�(]] DDDD
May Jun Jul
DD((l�
�DXDI
9eP
%%]7
DD((lj NW
J%]
Jan DU
D(]
IX) Apr
[%) l^I [%J
IX) Aug
IX)
Ixl
Od
(J(] N
Dec
Thermostat Schedule: HERS 2006 Reference
Hour
Schedule Type
1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WD) AM
78
78 78
78 78 78
78
78
80
80
80
8o
PM
80
80 80
80 78 78
78
78
78
78
78
78
Owling(WEH) AM
78
78 78
78 78 78
78
78
80
80
80
80
PM
80
80 80
80 78 78
78
78
78
78
78
78
Heating (WD) AM
65
65 65
65 65 65
65
68
68
68
68
68
PM
68
68 68
w 68 Se
68
68
68
w
w
68
Heating (WEH)
65
65
PM
68
68 68
88 668 68
88
68
88
68
68
68
4/2&201511:54 AM EnergyGauge® USA - FlaRes2010 SxBDn 405.4.1 Compliant SoBware Page 4 of 5
FORM 40510
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: 110 SANDY BEACH LN PERMIT #:
ATLANTIC BEACH, FL, 32233-
MANDATORY
223&
MANDATORY REQUIREMENTS SUMMARY -See individual code sections for full details.
COMPONENT
SECTION
SUMMARY OF REQUIREMENT(S)
CHECK
Air leakage
402.4
To be caulked, Basketed, weatherstripped or otherwise sealed.
Recessed lighting IC -rated as meeting ASTM E 283. Windows and
doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces:
X
gasketed doors & outdoor combustion air. Must complete envelope
leakage report or visually verity Table 402.4.2.
Thermostat &
403.1
At least one thermostat shall be provided for each separate heating and
controls
cooling system. Where forced -air furnace is primary system,
programmable thermostat is required. Heat pumps with supplemental
X
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts
403.2.2
All ducts, air handlers, filter boxes and building cevifies which forth the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
X
sealed in accordance with Section 503.2.7.2 of this code.
4D3.3.3
Building framing cavities shall not be used as supply ducts.
Water heaters
403A
Heat trap required for vertical pipe risers. Comply with efficiencies in
Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric) or shutoff (gas). Circulating system pipes insulated to = R-2
X
+accessible manual OFF switch.
Mechanical
403.5
Homes designed to operate at positive pressure or with mechanical
ventilation
ventilafion systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics, crawlspaces, garages or outdoors adjacent
to pools or spas.
Swimming Pools
403.9
Pool pumps and pool pump motors with a total horsepower (HP) of = 1
& Spas
HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor -retardant Covers or a liquid cover or
other means proven to reduce heat loss except H 70% of heat from
site -recovered energy. Otfttimer switch required. Gas heaters minimum
�j A_
thermal efficiency=78%(82%after 4/16/13). Heat pump pool heaters
minimum COP= 4.0.
Cooling/heating
403.6
Sizing calculation performed & attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
X
equipment
occasion cooling or heating capacity requires separate system or
variable Capacity system. Electric heal>10kW must be divided into two
or more stages.
Ceilings/knee walls
405.2.1
R-19 space permitting.
X
4128/2015 11:54 AM EnergyGauge& USA- FlaRes201O Section 405.4.1 Compliant Software Page 5 of 5
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 52
The lower the EnergyPerforrnance Index, the more efficient the home.
110 SANDY BEACH LN, ATLANTIC BEACH, FL, 32233-
1, New const uclion or existing
2. Single family or multiple family
3. Number of units, 8 multiple family
4. Number of Bedrooms
5. Is Mis a worst case?
S. Conditioned floor area dt2)
7. Windows•' Description
a. U-Fador. DN,U=0.30
SHGC: SHGC=0.30
b. U-Fador N/A
SHGC:
c. U -Factor: N/A
SHGC:
d. U-Fadar N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
6, Floor Types
a. Slab -0n -Grade Edge Insulation
In. N/A
c. N/A
Near (From Plans)
9. Wall Types
Multi -family
a. Frame - Wood, Exterior
Insulation
b. Frame - Wood, Common
1
c. N/A
3
d. N/A
R=
10. Ceiling Types
No
a. Under Attic(Vented)
1140
b. NIA
R=
c. N/A
Area
11. Ducts
130.11 ft'
a. Sup: Attic, Ret: AViL, AH: 2nd Floor
fl'
12. Coding systems
N
a. Cental Unit
13. Heating systems
e. Electric Heat Pump
14. Hot water systems
a. Electric
b. Conservation features
None
15. Credits
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code complia
Builder Signature: pp Date:
Address of New Home: )( Ixgol* d4-s-� City/FL Tp:
F 32233
Insulation
3.338 ft.
R=19.0
0.300
Insulation
Area
R=0.0
572.00 ft'
R=
IP
R=
ft'
13. Heating systems
e. Electric Heat Pump
14. Hot water systems
a. Electric
b. Conservation features
None
15. Credits
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code complia
Builder Signature: pp Date:
Address of New Home: )( Ixgol* d4-s-� City/FL Tp:
F 32233
Insulation
Area
R=19.0
1138.70 W
R=19.0
498.67 W
R=
ft'
R=
P
Insulation
Area
R=30.0
572.00 IF
R=
fl'
R=
ft'
R ft
6 142
kBludir
Effciancy
24.0
SEER 15
kBtu/hr
Efficiency
24.0
HSPF:570
Cap: 50 gallons
EF: 4.5
None
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
EnegyGeuge® USA- FlaRea2010 Section 405.4.1 Compliant Software
TABLE 402.4.2
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
project Name: TRIPLEX4/NIT-C Builder Name: BEACHES HABITAT
Street 110 SANDY BEACH LN Permit Offca: CITY OF ATLANTIC BEACH
City, Slate, Zip: ATLANTIC BEACH, FL, 32233- Permit Number:
Owner: Junsdiction: 261100
Design Location: FL, Jacksonville
COMPONENT
CRITERIA
CHECK
Air barrier and thermal barrier
Exterior thermal envelope insulation for framed walls is installed in
substantial Contact and continuous alignment with building envelope
air barrier.
Breaks or joints in the air barrier are filled or repaired.
Air -permeable insulation is not used as a sealing material.
\�
Air -permeable insulation is inside of an air barrier.
7�
Ceiling/attic
Air barrier in any dropped ceiling/soffit is substantially aligned with
insulation and any gaps are sealed.
Attic access (except unvented attic), knee wall door, or drop down
stair is sealed.
Walls
Comers and headers are insulated.
Junction of foundation and sill plate is sealed.
X
Windows and doors
Space between window/doorjambs and framing is sealed.
Rim joists
Rim joists are insulated and include an air barrier.
X
Floors (including
Insulation is installed to maintain permanent contact with underside
above -garage and cantilevered
of subfloor decking.
floors)
Air barrier is installed at any exposed edge of insulation.
Crawl space walls
Insulation is permanently attached to walls.
Exposed earth in unvented crawl spaces is covered with Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations
Duct shafts, utility penetrations, knee walls and flue shafts opening
to exterior or unconditioned space are sealed.
Narrow cavities
Batts in narrow cavities are Out to fit, or narrow Cavities are filled by
sprayed/blown insulation.
�C
Garage separation
Air sealing is provided between the garage and Conditioned spaces.
IVA
Recessed lighting
Recessed light fixtures are air tight, IC rated, and sealed to drywall.
u.
Exceptiorfixtures in Conditioned space.
Plumbing and wiring
Insulation is placed between outside and pipes. Batt insulation is cut
to fit around wiring and plumbing, or sprayed/blown insulation
u
extends behind piping and wiling.
Shower/tub on exterior wall
Showers and tubs on exterior walls have insulation and an air barrier
separama Nem from the exterior wall.
Electrical/phone box on
Air barrier extends behind boxes or air sealed -type boxes are
installed.
1C
Common wall
Air barrier is installed in Common wall between dwelling units.
V
HVAC register boots
HVAC register boots that penetrate building envelope are sealed to
subfloor or drywall.
X
Fireplace
Fire lace walls include an air barrier.
EnergyGaugeO USA- FlaRes2010 Section 405.4.1 Compliant software
wri htsoft Manual S Compliance Report Job: HABIJAX-TRIPLEX-UNIT
9 Date: 0212015
Entire House By: JLF
FLORIDA AIR SERVICE & ENGINEERING
1W HILDEN RD 303, PONTE YEDRE, FL 32081 Phwe. 9WQ3- % Email, FAEQENGINEER.COM Web: WMN.NORTWLORID vRCOM
Project Information
For: HABIJAX-TRIPLEX-UNIT-C-MJ, BEACHES HABITAT
110 SANDY BEACH LN, ATLANTIC BEACH, FL 32233
Cooling Equipment
Design Conditions
Outdoor design DB:
92.0'F
Sensible gain:
17799
Btuh Entering coil DB: 76.2°F
Outdoor design WB:
78.0'F
Latent gain:
2383
Btuh Entering coil WB: 63.2°F
Indoor design DB:
75.0'F
Total gain:
20182
Btuh
Indoor RH:
50%
Estimated airflow:
800
cm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type:
Split ASHP
Model: 25HBC524+FX4DNF025
Actual airflow: 800
Manufacturer:
CARRIER
Output capacity: 17775
Model: 25HBC524+FX4DNF025
Actual airflow:
800
cfm
Btuh
Sensible capacity:
11160
Btuh
63% of load
Latent capacity:
2601
Btuh
109% of load
Total capacity:
13762
Btuh
68% of load SHR: 81%
3. 1.11119.
• •
Design Conditions
Outdoor design DB: 39.0'F Heat loss: 21760 Btuh
Indoor design DB: 70.0'F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: CARRIER
Model: 25HBC524+FX4DNF025
Actual airflow: 800
cfm
Output capacity: 17775
Btuh
82% of load
Supplemental heat required:
3986
Btuh
Backup equipment type:
Elec strip
Manufacturer:
Model:
Actual airflow: 800
cfm
Output capacity: 5.2
kW 82% of load Temp. rise: 0 'F
The above equipment was selected in accordance with ACCA Manual S.
Entering coil DB: 69.5°F
Capacity balance: 39 'F
Economic balance: -99 °F
H�H wrightSOft Right-SulaaO U Normal 2013 13.0.09 R5U1355• 301STyr-2312:02:25
.-alwammm HVAC\H4BUM-TRIPLEX-UNIT- WM , Cal. -MJB B m, Fmnl boa, W PpH
Residential Plans Examiner Review Form
for HVAC System Design (Loads, Equipment, Ducts)
Header Information
Contracto, FLORIDA AIR
SERVICE
REQUIRED ATTACHMENTS
ATTACHED
Indoor temperature:
75
Manual A Form (and supporting workeheots):
Yes
❑
No
Mechanical licence: CAC1813923
ceMJ1AE Farm'(add supposing worksbsete):
Yea
[]
No E]
gas,
Bah Insemal shade:
OEM performance data (heating, cooling, blower):
Yee
❑
No ❑
Building plan #:
Bap nas.anoes. a•.
Manual D Fiction Rate Worlu b bi
Yes
❑
No ❑
Total heat gain.
20182
Duct distribution sketch:
Yes
❑
No
Home address (Street or Lag, Block, SubdMaion): 110 SANDY BEACH LN, Entire House
•
1
HVAC ••• CALCULATION (IRC
M1401.3)
Heatingfgsinment Data
CooliD9 EaninmaTI Dafa
Rlnwer
Dee tin Cnnditions
Building Constndction Inforrnat on
Split ASHP
E Wigment lie
Neel
Splft ASHP
Winter Design Conditions
800
Building
axw wo,meu
Outdoor temperature:
39 °F
Orientation: Building Front faces West
CARRIER
Motley.
CARRIER
Indoortemperetule:
7D •p
xann.0..1,we�se�u,,xonnsan xo,sg,...r
25HBC52NFX4DNF025
nnsnw.m,ne weaom.un ro. a.asn
�.Iv
Helafin oQ puv�Rv enawwasacewtl
Total heat loss:
21780 Btuh
Number of bedrooms: 3
Summer Design Conditions
Conditioned Boor area: 1140 ft'
Number of occupants: 0
Outdoor temperature:
92 °F
Indoor temperature:
75
°F Windows
Grains dl 58 grAb Eaveovshade depth:
1p fl
heat
Sensible heat Bain:2383
7993
gas,
Bah Insemal shade:
none
Latent heat gain:
2383
Bap nas.anoes. a•.
Total heat gain.
20182
8tuh Number of skylights:
p
EQUIPMENTHVAC
•
1
Heatingfgsinment Data
CooliD9 EaninmaTI Dafa
Rlnwer
Data
Eiu :Lae,M t pWem
x. eonw.
Split ASHP
E Wigment lie
Neel
Splft ASHP
Heeling tm:
800
>. •m
axw wo,meu
Cooling con:
800
Model:
CARRIER
Motley.
CARRIER
Static pressure:
0.50 in H2O
25HBC52�I4`FX4DNF025
25HBC52NFX4DNF025
nnsnw.m,ne weaom.un ro. a.asn
�.Iv
Helafin oQ puv�Rv enawwasacewtl
�e aiBlob
Total cooling capacity:
13782 Blob
Sensible cooling capacity:
11180 Mob
Aux. heating output capacity:
17782 Bah
Latent cooling capacity:
2801 Brun
• •
•
•l
Design aimow.
800 din
Longest supply duct 377 It
Duct Materials
Used
Equipment design ESP.
0.50 In H2O
Longest return dud : 0 it
Trunk duct
Total device pressure losses:
0 in H2O
Total eeecdve length(TEL): 35S7007 B
Available static pressure )ASP):
0.50 In H2O
Friction kaio�Rae=nswlre Q'tan0 in1100o Branch dud
Rcund•lex vinyl
Contractors printed name: J FERNANDEZ
Contractor's signature: J FERNANDEZ (E—SIGN) Date: 04/2015
Reserved for County. Town Municipality or Authority having jurisdiction use.
+wrlghtsoft RNN-sort a universal rola 13.0.00 Raut 35%
wrightsoft Building Analysis SIS Job: HABIJAX-TRIP LEX-U NIT-...
Date: 0212015
Entire House By: JLF
FLORIDA AIR SERVICE & ENGINEERING
150 HaDEN 40305, P NTE WDRE. FL 32091 PM1one: W48.. Em IMQUGINEER.CON Wb: N ..N0RT+L0MIWfiI.004A
For.
HABIJAX-TRIPLEX-UNIT-C-MJ, BEACHES HABITAT
%of load
Walls 2.7
1728
110 SANDY BEACH LN, ATLANTIC BEACH, FL 32233
Glazing 48.3
11682
53.2
Design
D
0
Ceilings 1.0
Conditions
5.2
Floors 1.3
1431
6.6
Indoor:
Heating
Cooling
Jacksonville Mayport Naval, FL, US
Indoor temperature (°F)
70
75
Elevation: 16 ft
0
Design TD ('F)
31
17
Latitude: 30°N
0
Relative humidity (%)
40
50
Outdoor:
Heating Cooling
Moisture difference(grAb)
15.7
58.2
Drybulb ff)
39 92
Infiltration:
0
Adjustments
Dailyrangs CF)
- 15 (1
)
Method
Simplified
100.0
Npt Bulb(°F)
- 78
Construction quality
Average
Wind speed (mph)
15.0 7.5
Fireplaces
1 (Average)
Heating
Component BWMF
Stun
%of load
Walls 2.7
1728
7.9
Glazing 48.3
11682
53.2
Doors 0
D
0
Ceilings 1.0
1131
5.2
Floors 1.3
1431
6.6
Infiltration 3.7
3304
15.2
Ducts
2585
11.9
Piping
0
0
Humidification
0
0
Ventilation
0
0
Adjustments
0
0
Total1
1 217601
100.0
0
Blower
Component
Blume
Stun
%of load
Walls
1.4
911
5.1
Glazing
46.3
11102
62.4
Doors
0
0
0
Ceilings
1.7
1983
11.1
Floor;
0
0
0
Infiltration
0.8
735
4.1
Ducts
3069
17.2
Ventilation
0
0
Internal gains
0
0
Blower
0
0
Adjustments
0
Total
1
1 177991
100.0
Latent Cooling Load = 2383 Btuh
Overall U -value =0.162 Btuh/f-'F
Data entries checked.
J
'et+ wrightsoft' RWW4.kSD Jovxsa1201911.0.W RSut355L 201a/p-i9laxas
. x%N haof NVPCUN&-MPLE%-uNn-C-Wnp C -MA &Tamp FmN lecec W P•Se
Prot SJet,: "ABIJAR TRIPLEX UNIT-..,
+ wrightsoft Project Summary Date: 0212015
Entire House By: JLF
FLORIDA AIR SERVICE & ENGINEERING
1WHIl RD=.POMEWME.FL32001PIwn..8 2&%W E—ILFAEGENGINEER.CW. WWW WRTWUNUD/WIZOM
Project Information
For: HABIJAX-TRIPLEX-UNIT-C-MJ, BEACHES HABITAT
110 SANDY BEACH LN, ATLANTIC BEACH, FL 32233
Notes:
Design Information
Weather: Jacksonville Mayport Naval, FL, US
Winter Design Conditions
Outside db 39 °F
Inside db 70 °F
Design TD 31 °F
Heating Summary
Structure 19175 Btuh
Ducts 2585 Btuh
Central vent (0 cfm) 0 Btuh
Humidification 0 Btuh
Piping 0 Btuh
Equipment load 21760 Bluth
Infiltration
Method Simplified
Construction quality Average
Fireplaces 1 (Average)
Heating Cooling
Area ("
1140
1140
Wlume(fla)
10250
10260
Air changes/hour
0.57
0.23
Equiv. AVF (chn)
97
39
Heating Equipment Summary
Make CARRIER
Outside db
92
Trade 2.0 TON
Inside cib
75
Model 25HBC524
Design TD
17
AHRI ref 3645571
Daily range
L
Efficiency
8.7
HSPF
Heating input
Moisture difference
58
Heating output
24000
Btuh @ 47`F
Temperature rise
27
°F
Actual air flow
800
din
Air flow factor
0.037
cfm/Btuh
Static pressure
0.50
in H2O
Space thermostat
Summer Design Conditions
Outside db
92
°F
Inside cib
75
°F
Design TD
17
'F
Daily range
L
Btuh
Relative humidity
50
%
Moisture difference
58
grllb
Sensible Cooling Equipment Load Sizing
Structure 14731 Btuh
Ducts 3069 Btuh
Central vent (0 cfm) 0 Btuh
Blower 0 Btuh
Use manufacturer's data
y
Rate/swing multiplier
1.00
Equipment sensible load
17799
Btuh
Latent Cooling Equipment Load Sizing
Structure
1555
Btuh
Ducts
828
Btuh
Central vent (0 cfim)
0
Btuh
Equipment latent load
2383
Btuh
Equipment total load
20182
Btuh
Req. total capacity at 0.78 SHR
1.9
ton
Cooling Equipment Summary
Make CARRIER
Trade 2.0 TON
Cord 25HBCS24
Coil FX4DNF025
AHRI ref 3895571
Efficiency
15.25 SEER
Sensible cooling
18720
Btuh
Latent cooling
5280
Btuh
Total cooling
24000
Bluth
Actual air flow
800
cfm
Air flow factor
0.045
cfm/Btuh
Static pressure
0.50
in H2O
Load sensible heat ratio
0.88
Calculations approved by ACCA to meet all requirements of Manual J &h Ed.
2015Jp-:e 12 W.04
wrI htsot RIOM80at U aN..120133OM RSU15
Ppp1
...a1N1gMw11 HVACVNBIJA%-TRIPIf%-LMITGMJNp G -Nue aWElnp Fmnlleu¢: W
AED Assessment Job: HABIJAX-TRIPLEX-UNIT-...
wrightsoft Date: 02=15
Entire House By: JLF
FLORIDA AIR SERVICE & ENGINEERING
1 W HILDEN RD 308. PONTE Y DRE FL 32081 Phone: 93482395g5 En ed, FA CENGINEERAOM Web: VNM/ NORT W LORIDANRLOM
For: HABIJAX-TRIPLEX-UNIT-C-MJ, BEACHES HABITAT
110 SANDY BEACH LN, ATLANTIC BEACH, FL 32233
Test for Adequate Exposure Diversity
»v,a
Maximum hourly glazing load exceeds average by 16.4%.
House has adequate exposure diversity (AED), based on AED limit of 30%.
AED excursion: 0 stun
wri htsoft 2015 -2812W:m
g Rip M1l-$uill9 U nrvMHB12013130 N R5Ul MM Rose
_sPMghboll HVAQH IJPX- TRIPLEX -UNIT -C-MJ.mp Calc =MA Building Front home W
Design
Location:
Indoor:
Heating
Cooling
Jacksonville Maypon Naval, FL, US
Indoor temperature (T)
70
75
Elevation: 16 R
Design TD (°F)
31
17
Latitude: 30°N
Relative humidity (%)
40
50
Outdoor: Heating
Cooling
Moisture difference(grAb)
15.7
58.2
Drybulb ff) 39
92
Infiltration:
Dailyrange CFS -
15 (L
)
Vletbulb(°F) -
78
Wind speed (mph) 15.0
7.5
Test for Adequate Exposure Diversity
»v,a
Maximum hourly glazing load exceeds average by 16.4%.
House has adequate exposure diversity (AED), based on AED limit of 30%.
AED excursion: 0 stun
wri htsoft 2015 -2812W:m
g Rip M1l-$uill9 U nrvMHB12013130 N R5Ul MM Rose
_sPMghboll HVAQH IJPX- TRIPLEX -UNIT -C-MJ.mp Calc =MA Building Front home W
Component Constructions Job: HABIJAX-TRIPLEX-UNIT-...
wrightsoft P Date: o2rm15
Entire House By: JLF
FLORIDA AIR SERVICE 8, ENGINEERING
1WHIL0ENRD3W,PONTEVEDRE.1L32n01 Phone: 93"2}9556 Email: FhEsi,ENGINEER.COMV{b:W ,NORTHFLORIDMIR.COM
Project Information
For: HABIJAX-TRIPLEX-UNIT-C-MD, BEACHES HABITAT
110 SANDY BEACH LN, ATLANTIC BEACH, FL 32233
']es:inn Cnnditir
Location:
Or
Indoor:
Heating
Cooling
Jacksonville Mayport Naval, FL, US
Loss
Indoor temperature (°F)
70
75
Elevation: 16 R
T
Design TD (°F)
31
17
Latitude: 30°N
BMrR
Relative humidity (%)
40
50
Outdoor: Heating
Cooling
Moisture difference (gnlb)
15.7
58.2
Drybulb(°F) 39
92
Infiltration:
n
631
Dailyrarge (°F) -
15 (L )
Method
Simplified
1.41
Nkt bulb ('F) -
78
Construction quality
Average
0.086
Wind speed (mph) 15.0
7.5
Fireplaces
1 (Average)
65
Construction descriptions
Or
Area
U -value
Insul R
Htg HTM
Loss
Olg HTM
Gain
T
aNM-'F
R --E.
BMn6
aNa
BMrR
sam
Walls
12B-21hw: Firm wall, brk 4" ext, Ell cav ins, 2-x4" wood firm, r-2 int bd
n
631
0.086
13.0
2.67
1682
1.41
087
ins
a
46
0.086
13.0
2.67
123
1.41
65
all
677
0.086
13.0
2.67
1805
141
952
Partitions
(none)
Windows
10A -m: 1 glazing, reflective (1/4' only) g12, and no bark hm mel. 114" thk,
n
77
1 s70
0
51.8
3986
27.6
2123
high rod pert: 8 fl overhang (8It.,Mow hl, 6 fl esp.)
I A -c1 am: 1 gli ang, or 9b, antl no bark final mal. 118" thk. 1 ft overhang (6
a
34
1.270
0
39.4
1339
935
3100
8 window hr 2 fl sap.)
Doors
(none)
Ceilings
16B-30ad: Adic ceiling, asphalt shingles roar mat, r-31 root ins, P30 cell
n
1140
0.032
30.0
0.99
1131
1.74
1983
ins
Floors
22A-Wh'. Bg floor, heavy damp soil, on grade depth. Nnyl fir loan
n
34
1.358
0
42.1
1431
0
0
2015Apr-2e I1156:53
wrightsoft RI9M-Sullair Dn,inial 2M Us W RSU135U Palo
04M a\Ntigothohn WAGW I M-TRIPLEx UNIT-LMD.mp CW =We BW61ng Foom laxoS W
Component Constructions Job: HABIJAX-TRIPLEX-UNIT-...
wright5oft P Date: 0212015
BATH2 By: JLF
FLORIDA AIR SERVICE & ENGINEERING
150HIL0ENR030B.P0NTEVEDREFL32N1 Phors 91240&WN Emae FFECENGINEER.COMWer W AORTHFLORIO RCOM
Project Information
For: HABIJAX-TRIPLEX-UNIT-C-MD, BEACHES HABITAT
110 SANDY BEACH LN, ATLANTIC BEACH, FL 32233
7PAInn Cnnditic
Location:
Or
Indoor:
Heating
Cooling
Jacksonville Maypon Naval, FL, US
Loss
Indoor temperature ("F)
70
75
Elevation: 16 It
T
Design TD (°F)
31
17
Latitude: 30'N
.,e
Relative humidity (Mo)
40
50
Outdoor: Heating
Cooling
Moisture difference(grAb)
15.7
58.2
Dry bulb ('F) 39
92
Infiltration:
n
2
Dailyrange (°Fj -
15 ( L )
Method
Simplified
1.41
Watbulb(°F) -
78
Construction quality
Average
Wind speed (mph) 15.0
7.5
Fireplaces
1 (Average)
Construction descriptions
Or
Area
U -value
Insul R
Hlg HTM
Loss
Clg HTM
Gain
T
mofiM1'F
fir -T.
6N.M
Rrh
.,e
awa
Walls
1212-26w: Fm wall, bdc 4" ext, r-11 wv ins, 2"Wwood firm, r-2 int bit
n
2
0.086
13.0
2,67
5
1.41
3
Ins
Partitions
(none)
Windows
10A -m:1 glazing. reflective (1/4" only) gb, mg no brk Inn mat, 1M- Nk,
n
4
1.670
0
51.8
207
27.6
110
high Md pert, 8 fl overhang (8 fl window Is, 6 6 sap.)
Doors
(none)
Ceilings
16B-30ad: Attic wiling, asphalt shingles mot mat, r-31 roof ins, r-30 call
n
72
0.032
30.0
0.99
71
1.74
125
ins
Floors
22A-vph: Bg floor, heavy damp soil, on grade depth, vinyl fir loan
n
6
1.358
0
42.1
253
0
0
.GQ
zolSror-za1 wrighls"O tf Rig m-Sutab Universal 2)13 13o.09 RSU 1355• Paget
Page
HVNC\H4BIJPJ(-TRIPLEX-UNIT-GMO.mp Cdc=MJe BUNIrq Fronlhxe: W
Constructions Job: HABIJAX-TRIPLE%-UNIT
+f+ wrightsoft Component Date: 0212015
MEED By: JLF
FLORIDA AIR SERVICE & ENGINEERING
1WHILOENRD3 ,F WEV DRE.FL32091P1wia:WFa] %M Em :FAE®ENGINEER.CWM :V +NORTWLOMI R.COM
For: HABIJAX-TRIPLEX-UNIT-C-MD, BEACHES HABITAT
110 SANDY BEACH LN, ATLANTIC BEACH, FL 32233
Construction descriptions
Or Area
U -value
InsulR
His Hills
Loss
Design
Conditions
T
Indoor:
Heating
Cooling
Jacksonville Maypon Naval, FL, US
2Mar
Indoor temperature (°F)
70
75
Elevation: 16 ft
Design TD CF)
31
17
Latitude: 30°N
1213-21w: F. wall, bilk 4' ext, r-11 wv ins, 2"x4" wood Inn, r-2 int b8
Relative humidity (%)
40
50
Outdoor: Heating
Cooling
Moisture difference(gr/lb)
15.7
58.2
Drybulb(°F) 39
92
Infiltration:
Dailyrange (°F) -
15 (L
) Method
Simplified
Watbulb('F) -
78
Construction quality
Average
Wind speed (mph) 15.0
7.5
Fireplaces
1 (Average)
Construction descriptions
Or Area
U -value
InsulR
His Hills
Loss
Cie HM
Gain
T
sui
R -F.
BIIiA'
Ei
2Mar
sen
Walls
1213-21w: F. wall, bilk 4' ext, r-11 wv ins, 2"x4" wood Inn, r-2 int b8
n 111
0.086
13.0
2.67
296
1.41
166
ins
Partitions
(none)
Windows
1 OA-tn: 1 glazing, re9etlive (id" only) g2, m8 no brk f rn mat, 1/4 -Ni
n 31
1.670
0
51.8
1605
27A
855
high dict pert: 8 it overhaig (8 8 window, ht 6 ft up.)
Doors
(node)
Ceilings
1813-30ad'. Aftic ceiling, aspha8 shingles roof mat 01 roof Ins, r-30 rw9 in 181 0.032 30.0 0.99 180 1.74 315
ins
Floors
(none)
wrightxoft Right-iiuftb umvsel W1313.0.09 each 35% 2o15Apr-za1 rare :3
Py3
....1YtigMwa HVACVl4BLIAl(-rRIPLEIIUNnLM.no ctic•MJa w
wrightsoft Com Component Constructions Job: HABIJU-TRIPLU-UNIT
P Data: 0212015
BED2 By: JLF
FLORIDA AIR SERVICE & ENGINEERING
150HILDENRD30a.POWEY ME,FL32tIe1�a.E 21 N Emar:FMOEWNEER.COMN .: ..MUWLORIO WCOM
For:
HABIJAX-TRIPLEX-UNIT-C-MD, BEACHES HABITAT
U -value
Inial R
Htg HTM
110 SANDY BEACH LN, ATLANTIC BEACH, FL 32233
CIg HTM
Gain
Design
Conditions
R°Fendi
MII nt
aN
EMrF
Indoor:
Heating
Cooling
Jacksonville Mayport Naval, FL, US
Indoor temperature CF)
70
75
Elevation: 15 It
Design TD (°F)
31
17
Latitude: 30`N
2,67
Relative humidity (MP)
40
50
Outdoor:
Heating Cooling
Moisture difference (grAb)
15.7
58.2
Drybulb ff)
39 92
Infiltration:
Partitions
Dailymnge (°F)
- 15 (L
) Method
Simplified
Wet bulb ('F)
- 78
Construction quality
Average
Wind speed (mph)
15.0 7.5
Fireplaces
1 (Average)
Windows
Construction descriptions
Or Area
U -value
Inial R
Htg HTM
Losse
CIg HTM
Gain
T
asn M -r
R°Fendi
MII nt
aN
EMrF
BIM
Walls
12B-2bw. Frm wall, bid, C ext, r-11 cav ins, 2"x4' wood Ins r-2 int W
n 128
0.086
13.0
2,67
341
1.41
180
Ins
Partitions
(none)
Windows
10Am:1 glazing, relledive (114- only) glz, m8 no lark fnn mat, 1H- ihk,
n 14
1.670
0
51.8
725
27.6
386
high r8d part: 8 0 overhang is It window M, 6 0 sep.)
Doors
(none)
Callings
16B-30ed: AOic ceiling, asphah shingles mot mat, 01 root Ins, r-30 cell n 171 0.032 300 0.99 170 1.74 297
ins
Floors
(none)
I�H201SIp-2S1 wrightlsoh Rpm-6uXes UNvxs•1201313.0.0a RSU13S5r Pew Pass4
...swirly" HVPCe 14iO(-TRIPLEX-UMT- D.W Calc •MM Bases, FmN Mc W
Component Constructions Job: HABIJA%-TRIPLE%-UNIT-...
+ wrightsoft Date: 0212015
GREAT By: JLF
FLORIDA AIR SERVICE & ENGINEERING
1 W HILDEN RD". PONTE VEDRE FL 33na1 PInu: 6Ma2aa6aa Emelt: FAEaEN01NEER.00M WN: N ..NORM FLORIDAAR.COM
For: HABIJAX-TRIPLEX-UNIT-C-MD, BEACHES HABITAT
110 SANDY BEACH LN, ATLANTIC BEACH, FL 32233
Construction descriptions
Or
Ams
U -value
Maul R
Htg HTM
Design
Location:
Gain
Indoor:
Heating
Cooling
Jacksonville Maryport Naval, FL, US
R -'F9
Indoor temperature (°F)
70
75
Elevation: 16 R
Walls
Design TD (°F)
31
17
Latitude: 30°N
Relative humidity (%)
40
50
Outdoor: Heating
Cooling
Moisture difference(grAb)
15.7
58.2
Drybulb('F) 39
92
Infiltration:
156
ins
Daityraige (°F) -
15 (L
i Method
Simplified
2.67
Wetbulb(°F)
78
Construction quality
Average
a0
Wind speed (mph) 15.0
7.5
Fireplaces
1 (Average)
419
Construction descriptions
Or
Ams
U -value
Maul R
Htg HTM
Loss
Clg HTM
Gain
T
BMrM'F
R -'F9
ale.T'
BNh
BMM
aura
Walls
1213-2bw: F. wall, brk 4" ext, 111 wv ins, 2"%4- wood Inn, r-2 int W
n
111
0.086
13.0
2.67
296
1.41
156
ins
a
46
0.086
13.0
2.67
123
1.41
65
a0
157
0.086
13.0
2.67
419
1.41
221
Partitions
(no.)
Windows
1A-ctom'. 1 glazing, clr glz, m0 no brk firm mat, 118' ark; 1 8 overhang is
a
N
1.270
0
39.4
1339
93.5
3180
0 window In, 2 6 sep.)
Doors
(none)
Ceilings
16B-30ad: Aaic ceiling, asphalt shingles roof mat, 01 roof ins, r-30 cell
n
255
0.032
30.0
0.99
253
1.74
443
ins
Floors
22A-vph: Bg floor, heavy damp soil, on grade depth, vinyl Br loan
n
12
1.358
D
42.1
505
0
0
wrI htsoft Za1aOJr-2e1 Poems 9 Right-6ulNITiW.M M1313. a cede, F51 pyey
.a\V.tiOauoiI NVACVIABIJA%-TWPLE%-UNITLMD.nq C•Ic-MJe BurEina Fmnl M1cee: W
Component Constructions Job: HABUAX-TRIPLEX-UNIT-...
wrightsoft P Date: 9212015
MWIC By: JLF
FLORIDA AIR SERVICE & ENGINEERING
1 WHILDEN RD 308, PONTEMEDRE, FL32001 Phone -.9040219695 Email'. FAEeENGINEER.COM Nhb: vwaVN0RTl1FL0RIDMR60M
For: HABIJAX-TRIPLEX-UNIT-C-MD, BEACHES HABITAT
110 SANDY BEACH LN, ATLANTIC BEACH, FL 32233
Construction descriptions Or AreaU-value Insul R Htg HTM Loss Clg HTM Gain
r mrm-'r r-�Faen swm' srm 96nm w,a
Walls
126-21w: Fm waft, brk 4" ext, r-11 carr ins, Tag" wood fon, r-2 int W
ins
Partitions
(none)
Windows
(none)
Doors
(none)
Ceilings
1613-30ad: Aflic ceiling, aspha8 shingles root mat, r-31 root ins, r-30 tail n
ins
Floors
22A-vph'. Big floor, heavy damp soil, on grade depth, vinyl f r fnsh
9 0.068 13.0 2.67 24 1.41 13
32 0.032 30.0
8 1.358
0.99
32
174
56
42.1
337
Design
Location:
Indoor:
Heating
Cooling
Jacksonville Mayport Naval, FL, US
Indoor temperature ff)
70
75
Elevation: 16 R
Design TD (°F)
31
17
Latitude: 30"N
Relative humidity (%)
40
50
Outdoor: Heating
Cooling
Moisture difference (gr/Ib)
15.7
58.2
Drybulb(°F) 39
92
Infiltration:
Dailyrange ("F) -
15 (L
) Method
Simplified
Net bulb CIE) -
78
Construction quality
Average
Wind speed (mph) 15.0
7.5
Fireplaces
1 (Average)
Construction descriptions Or AreaU-value Insul R Htg HTM Loss Clg HTM Gain
r mrm-'r r-�Faen swm' srm 96nm w,a
Walls
126-21w: Fm waft, brk 4" ext, r-11 carr ins, Tag" wood fon, r-2 int W
ins
Partitions
(none)
Windows
(none)
Doors
(none)
Ceilings
1613-30ad: Aflic ceiling, aspha8 shingles root mat, r-31 root ins, r-30 tail n
ins
Floors
22A-vph'. Big floor, heavy damp soil, on grade depth, vinyl f r fnsh
9 0.068 13.0 2.67 24 1.41 13
32 0.032 30.0
8 1.358
0.99
32
174
56
42.1
337
a
0
- . 11 Wrl htsofReinsurers Me129 R5U1J55Page
..a\NlgMoHAAIATRIPLEX-UNIT-C-DMp CW=.J.
BuilEin9 Franl lana: W
Com onent Constructions Job: HABU"-TRIPLEX-UNIT-...
Wrightsoft p Date: 02MO15
BATH1 By: JLF
FLORIDA AIR SERVICE 8 ENGINEERING
I W HILDEN RD 308. POMEV DRE FL330BI PBone'. B 8219696 Emel'.FAECENGINEER.COMNkb: Mw NORTHFLORIDMR.COM
Project Information
For: HABIJAX-TRIPLEX-UNIT-C-MD, BEACHES HABITAT
110 SANDY BEACH LN, ATLANTIC BEACH, FL 32233
Construction descriptions Or Area U -value InsulR Htg HTM Loss Cie HTM Gain
T auhf--F T -'n @W BNB BMM BWI
Walls
1213-2bw: Fria wall, brk 4" eat, 111 cav Ina, 2'x4" wood firm, r-2 int bd n 6 0.086 13.0
ins
Partitions
(none)
Windows
(none)
Doors
(none)
Callings
16B-30ad: Aaic ceiling, asphalt shingles roof mat. r-31 roof ins, r-30 cell n 52 0.032 30.0
ins
Floors
(none)
267 16 1.41
0.99 52 1.74 90
+wrightS:Oft Ri9M-sene4 unne,.a12013 laoa0 RSU135s4 20 sror261 Pepe?
..s%ft,h1sas WAQH<BWJ JRIPLE-UNIT-GMunp CYc=MN Buaing FMI laces: W
Design
Location:
Indoor:
Heating
Cooling
Jacksonville Maypon Naval, FL, US
Indoor temperature ("F)
70
75
Elevation: 16 R
Design TD (°F)
31
17
Latitude: 30°N
Relative humidity 1%)
40
50
Outdoor: Heating
Cooling
Moisture dtfterence(grNb)
15.7
58.2
Dry bulb(°F) 39
92
Infiltration:
Dailyrange (°F) -
15 (L
) Method
Simplified
VLbtbulb(°F) -
78
Construction quality
Average
Wind speed (mph) 15.0
7.5
Fireplaces
1 (Average)
Construction descriptions Or Area U -value InsulR Htg HTM Loss Cie HTM Gain
T auhf--F T -'n @W BNB BMM BWI
Walls
1213-2bw: Fria wall, brk 4" eat, 111 cav Ina, 2'x4" wood firm, r-2 int bd n 6 0.086 13.0
ins
Partitions
(none)
Windows
(none)
Doors
(none)
Callings
16B-30ad: Aaic ceiling, asphalt shingles roof mat. r-31 roof ins, r-30 cell n 52 0.032 30.0
ins
Floors
(none)
267 16 1.41
0.99 52 1.74 90
+wrightS:Oft Ri9M-sene4 unne,.a12013 laoa0 RSU135s4 20 sror261 Pepe?
..s%ft,h1sas WAQH<BWJ JRIPLE-UNIT-GMunp CYc=MN Buaing FMI laces: W
Com onent Constructions Job: HABIJAX-TRIPLEX-UNIT....
wrlghtsoft P Date: 0212015
MECH By: JLr
FLORIDA AIR SERVICE & ENGINEERING
150 HILDEN RD 306 PONTE VEDRE FL 32001 Pxwe'. 80482>9696 Erred f FPEGENGINEER COM Well VNNJ.NORTXFLORID"R CoM
For: HABIJAX-TRIPLEX-UNIT-C-MD, BEACHES HABITAT
110 SANDY BEACH LN, ATLANTIC BEACH, FL 32233
Construction descriptions
Or
Area
U -value
Insul R
Mg HTM
Design
Location:
Gain
Indoor:
Heating
Cooling
Jacksonville Mayport Naval, FL, US
M -'F.
Indoor temperature (°F)
70
75
Elevation: 16 it
Walls
Design TD (°F)
31
17
Latitude: 30°N
Relative humidity (%)
40
50
Outdoor: Heating
Cooling
Moisture difference (901b)
15.7
58.2
Drybulb('F) 39
92
Infiltration:
11
ins
Dailymnge ('F) -
15 (L
) Method
Simplified
Wet bulb ('F) -
78
Construction quality
Average
Wind speed (mph) 15.0
7.5
Fireplaces
1 (Average)
Construction descriptions
Or
Area
U -value
Insul R
Mg HTM
Loss
Cls HTM
Gain
T
assire.T
M -'F.
losh
Walls
12&21bw. Fm wall, brk 4' ext, r-11 care ins, 2'xF' wood Bm, r-2 int bit
n
8
0.066
13.0
2.67
21
1.41
11
ins
Partitions
(none)
Windows
(none)
Doors
(none)
Ceilings
I BB-30adAl is ceiling, awha6 shingles roof mal r-31 roof ins, r-30 cell
n
48
0.032
30.0
0.99
48
1.74
83
Ins
Floors
22A-vph: Bg floor, heavy damp soil, on grade depth, vinyl Ar insh
n
8
1.358
0
42.1
337
0
0
11 sa 53
Wrightsoft' Right -Sidles Universal 2013 13,0,00 Rsu1355r Prove
\ Mwfi HVACrIRNEWPX- Ppae
_a VAp TRIPLEX-UNIT-C-1110mp Ctic=MJe BUNiq Frani leas: W
Construction descriptions Or
Component Constructions
p
Job: HABUAX-TRIPLEX-UNIT-...
WFlghtsoft
Htg HTM
Date: OWD15
Cis HTM
Gain
BED3
By: JLF
.e F
r- roan
FLORIDA AIR SERVICE & ENGINEERING
eN
eenm�
150 HIDDEN RD 309, PONW WDRE, FL 310n Plve: aD 3aGW Emti: FAEQENDINEER.COM WW: VNN4NORTHFL0PoDMRLCO1W
Walls
Project Information
For:
HABIJAX-TRIPLEX-UNIT-C-MD, BEACHES HABITAT
128
0.086
130
110 SANDY BEACH LN, ATLANTIC BEACH, FL 32233
341
1.41
180
ins
Design Conditions
Location:
Indoor:
Heating
Cooling
Jacksonville Maypon Naval, FL, US Indoor temperature ('F)
70
75
Elevation: 16 8
Design TD (°)
31
17
Latitude: 30'N
Relative humidity (%)
40
50
Outdoor:
Heating Cooling Moisture difference (grAb)
15.7
58.2
Drybulb(°F)
39 92 Infiltration:
Dailyrange CF)
- 15 (L ) Method
Simplified
Watbulb(`F)
- 78 Construction quality
Average
0
Wind speed (mph)
15.0 7.5 Fireplaces
i (Average)
386
Construction descriptions Or
Area
U -value
Insul R
Htg HTM
Loss
Cis HTM
Gain
re
.e F
r- roan
mna•
eN
eenm�
..h
Walls
12B -26w: Frm wall, brk 4" ext r-11 caV ins, 2NV wood man. r-2 int W n
128
0.086
130
2.67
341
1.41
180
ins
Partitions
(none)
Windows
10Avn: 1 glazing, reflective (1/4' only) gb, m8 no lxk fml mat, 114'thk, n
14
1.670
0
51.8
725
27.6
386
high did ped:8 fl a.m., is ft window hl, 68 "P.)
Doom
(none)
Callings
166-30ad: Attic ceiling, mmhah shingles root met. r-31 roof ins, r-30 cell n 151 0.032 30.0 0.99 150 1 74 263
Ins
Floors
(none)
F
2n1SPyr-3a1
WnlghtsoR RIgMSuh•a UnwvSa1201313.0.0a RSD135N Pss
...a\Wp11boI1 RVACVNBIJA%-TRIPLEX-MT- MO.n, Cat -MM BUMV Form iwa W
Com onent Constructions Job: HABIJ"'TRIPLE%-UNIT-...
' Wrightsott P Data: 0212015
KITCHEN By: JLF
FLORIDA AIR SERVICE 8 ENGINEERING
150HILDEN RD W8, PONTEV DRE FL 32081 Plona: 9J4823%% Email'. FPECENGINEERCOM iNam N NORTHFLORIDMRCOM
For: HABIJAX-TRIPLEX-UNIT-C-MD, BEACHES HABITAT
110 SANDY BEACH LN, ATLANTIC BEACH, FL 32233
'11pizinn Conditic
Location:
Area
1.1 -value
Indoor:
Heating
Cooling
Jacksonville Mayport Naval,
FL, US
Indoor temperature (°F)
70
75
Elevation: 16 It
aNh
BEAr1P
Design TD (°F)
31
17
Latitude: 30°N
Relative humidity (%)
40
50
Outdoor:
Heating
Cooling
Moisture difference(grAb)
15.7
58.2
Drybulb(°F)
39
92
Infiltration:
Dailyrange (°F)
-
15 (L )
Method
Simplified
Wat bulb ('F)
-
78
Construction quality
Average
Wind speed (mph)
15.0
7.5
Fireplaces
1 (Average)
Construction descriptions Or
Area
1.1 -value
Insul R
His HTM
Loss
Cis HTM
Gain
W
a,ma.1
R'1.
BMi11`
aNh
BEAr1P
wua
Walls
12B -20w: Fran wall, brk 4" eA, 01 cav ins, 2"X4" wood ft., r-2 int bd n
128
0.086
13.0
2.67
341
1.41
180
ins
Partitions
(none)
Windows
10A -m: 1 glazing, re6ective (1R- only) glz, m8 no brk 1r1n mat, 114'thk, In
14
1.670
0
51.8
725
27.8
386
high and pert: 8 fl overhang is ft window ht, 6 R sep.)
Doors
none)
Ceilings
16B-30ad: Aeic ceiling, asphaR shingles roof mat, r-31 root ins, r-30 veil In 178 0.032 30.0 0 99 177 1.74 310
Ins
Floors
(none)
wri htsoft za+sAyr-ze 11:5 e: so
9 Rig m -saheb U mxaal 2013+a.00e RSU 13554 Pape+D
� ...e\NhgMaoaWAC\IU&JMTRIPLEX-UNIT- MD.mp Calla. kJw,g Frmlfwa. W
Duct System Summary Job: HABIJAX-TRIPLEX-UNIT...
Wrightsoft Dale: 0212015
Entire House By: JLF
FLORIDA AIR SERVICE 8 ENGINEERING
1WHILDEN RD206. PONTEVEDRE, FL32001 Piv-:80682}6896 E :FAE®ENGINEER.COM VM: NYM WRTKLOMI R.GOM
For: HABIJAX-TRIPLEX-UNIT-C-MD, BEACHES HABITAT
110 SANDY BEACH LN, ATLANTIC BEACH, FL 32233
Supply Branch Detail Table
Name
Heating
Cooling
External static pressure
0.50 in H2O
0.50 in H2O
Pressure losses
0 in H2O
0 in H2O
Available static pressure
0.50 in H2O
0.50 in H2O
Supply / return available pressure
0.250 / 0.250 in H2O
0.250 / 0.250 in H2O
Lowest friction rate
0.500 in/1008
0.500 IN7008
Actual air flow
800 Urn
800 din
Total effective length (TEL)
MM
377 R
Supply Branch Detail Table
Name
Design
(Btuh)
Hit;
Wml
Clg
(Cfm)
Design
FR
Diam
(in)
H x W
(in)
Duct
Mau
Actual
Ln (fl)
Ftg.Egv
Ln (ft)
Trunk
MECH
h 544
28
10
0.500
4.0
0x0
VIFx
307.0
70.0
MM
h 696
36
25
0.500
4.0
Oxo
VIFx
307.0
70.0
MBEO
It 3317
173
148
0.500
7.0
0(0
VIFx
307.0
70.0
BED6
It 2245
117
97
0.500
6.0
0x0
VIFx
307.0
70.0
IOTOHEN
It 2278
119
102
0.500
6.0
0x0
VIFx
307.0
70.0
BED2
h 2270
119
101
0.500
6.0
0x0
VIFx
307.0
70.0
GREAT
c 2103
87
149
0.500
6.0
0x0
VIFx
307.0
70.0
WF TA
c 2103
87
149
0.500
8.0
Oxo
VIFx
307.0
70.0
BATH1
c 149
6
11
0.500
4.0
Oxo
VIFx
307.0
70.0
MLMc
In 533
28
8
1 0.500
4.0
Oxo
1 VIFx
1 307.0
170.0
a 11SAyr-26113625
WrightstOft Rig M-6uXSIDUN WSM201313AMRSU125N P.,I
.AM.-31lM hM HVACW IJAx-TRIPUe-UNITG*W.n CWb-MJfi BoWQ FMI ftc : W
Oil
Certificate of Product Ratings
AHRI Certified Reference Number: 3645571 Date: 4/27/2015
Product: Split System: Heat Pump with Remote Outdoor Unit -Air -Source
Outdoor Unit Model Number: 25HBC524Aam30
Indoor Unit Model Number: FX4DNF025
Manufacturer: CARRIER AIR CONDITIONING
Trade/Brand name: CARRIER
Series name: COMFORT 13 PURON HP
Manufacturer responsible for the rating of this system combination is CARRIER AIR CONDITIONING
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air -Conditioning and Air -Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third
party testing:
Cooling Capacity (Btuh): 24000
EER Rating (Cooling): 12.00'
SEER Rating (Cooling): 15.25
Heating Capacity(Btuh) @ 47 F: 24000
Region IV HSPF Rating (Heating): 8.70
Heating Capacity(Btuh) @ 17 F: 14700
• Forngad'—no by an astensx (9 imitate a vaunlery re2te or praviw4y pumvrrm ere. areae s—,.n. wiln a S. wI ich bdiwma en mwwman reale.
DISCUIMER
AHRI dues not and. the prodiefil) listed on this Certificate and makes no represeMatlons, wartannes or guarantees as to, and assumes no responsibility for,
elle pum uct s) listed on this Contractile. AHRI expresdy disclaims all liability for dormice of .,kind arltln$ate of Ne use or perlamlan[e Of the pcidutl(q, or the
unmehodzed liberation of data listed on this Certificate. canki mints; am valid only far models and cmflAurations listed In the
directory M—shrldlrictri, rg,
CONDITIONS
TERMS AND CONDITIONS
This Certificate and as care prbprletary products of AHRI. This Certificate shall only be used far Individual, personal and
JUR
confidential reference purposes. TDs contents of this Certificate may nor, In whole or In part, be reproduced; counsel dlsseminamd;
entered into a computer database or otherwise elllzed, In any form or manner or by any means, except for the ueei s Individual,
personal and cbnfidenNel reference. AIR-CONDIRIONIN0, HEATInO,
6 REEMCERATION msmezE
CERTIFICATE VERIFICATION
The informehonlar the model cited on this cookware can be vedfled at wwwsDtldlmctory.org, tuck on 'Verify CertlficaW link inat, I I1, b,uvr"
and enter the AX Certified Reference Number and Me date on which Me cortlhcate was Nsue4
which is listed above, and the CertMmte No., which Is listedel am am dga 130746131619109909
CERTIFICATE NO.:
@2014 Air-Condltloning, Heating, and Retrigeretion Institute
BEACHES HABITAT
102-106-110 SANDY BEACH LN
ATLANTIC BEACH, FL 32233
TRIPLEX MECHANICAL PLAN - M2
BEACHES HABITAT
102-106-110 SANDY BEACH LN
ATLANTIC BEACH, FL 32233
TRIPLEX MECHANICAL PLAN - M1