122 SANDY BEACH LN - ENERGY SHEETS FORM 405-10
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Protect Name: DUADPLEX-UNITS Builder Name: BEACHES HABITAT
Street 122 SANDY BEACH LN Permk Office: CITY OF ATIATNCI BEACH
City,Stale,Zip: ATLANTIC BEACH,Ft ,32233- Permd Number:
OwnerJurisdiction: 261100
Design Location: FL Jacksonville
1. New construction or existing New(From Plans) 9, Wall Types(1699.3 self.) Insulation Area
2. Single family or muftipte family MuIO-family a.Frame-Wood,common R=19.0 1100.00 ft'
b.Frame-Wood.Exterior R=19.0 599.33 fl'
3. Number of units,8 multiple family t c.WA R= fl'
4. Number of Bedrooms 2 d.N/A R= ft'
5. Is This a worst case? No 10.Ceiling Types (658.0 "ft.) Insulation Area
a.Under Able(Vented) R=30.0 658.00
6. Conditioned floor area above gratia(ft) 1227 b.N/A R= fl2
Conditioned floor area below grade(f) 0 .WA R= fl
11.01) fl
ucts R
]. Wintlows(98.2 sgflJ Description Area a.Sup:Allic,Ret:Attic,AM:21ntl Floor 6 742
a. tUFactor, ON,U=0.30 98.17 f?
SHGC: SHGC=0.30
b. U-Fetor WA ft' 12.Cooling systems Wbilhr Efficiency
a.Central Unit 24.0 SEERA5.25
SHGC:
c. U-Factor: N/A ft'
Si 13.Heating systema kBtumr Efficiency,
d. U-Factor WA ft' a.Etectnc Heed Pump 24.0 HSPF:8.70
SHGC:
Area Weighted Average Overhang Depth: 2.404 ft.
Area Weghled Average SHGC' 0.300 14.Hot water systems
a.Electric Cap:50 gallons
8. Floor Types (658.0 sgft.) Insulation Area EF:4.500
a.SlabOn-Grade Edge Insulation R=0.0 656.00 ft' In. Conservation features _
b.NIA R= 8' None
c.N/A R= rye 15.Credits None
Glass/Floor Area: 0.080 Total Proposed Modified Loads: 12.36 PASS
Total Standard Reference Loads: 23.37
I hereby certify that the plans s covered by Review of the plans and 0, 1HE STgrF
this calculation are in rrpygl F 'da Energy specifications covered by this y z QR,
Code. ( � calculation indicates compliance
with the Flonda Energy Code. "••. :1 '''. b
PREPARED BY: J FERNANDEZ Before construction is completed u�
DATE: 04 2015 this building will be inspected for V ��))'' a
compliance with section 553.908
I hereby ceri fy that this building,as designed, is in compliance Flonda Statutes. •lf, = yt e
with the Florida Energy Code. COO WE•�J
OWNERIAGENT: BUILDING OFFICIAL:
DATE: r7-� �• DATE:
- Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist
4/28/2015 9:41 AM EneigyGauge®USA-FlaRes2010 Section 406.4.1 Compliant Software Page 1 of 5
PROJECT
Title: OUADPLEX-UNITC Bedrooms: 2 Address Type: Street Address
Building Type: User CondBioned Area: 1227 Lot#
Owtsr: Total Stories: 2 BlocWSubDMsion: County Seal
#of Units: 1 Worst Case: No PlatBook: Book 103n,page 345
Builder Name: BEACHES HABITAT Robins Angle: 0 Street: 122 SANDY BEACH LN
Parmit Office: CITY OF ATLATNCI BEACH Cross Ventilation: No County: DUVAL
Jurisdiction: 261100 Whole House Fen: No City,Stale,Dip: ATLANTIC BEACH,
Family Type: Mulb-family FL, 32233
NawlEusli New(From Plans)
Comment:
CLIMATE
IECC Design Temp Int Design Temp Heating Design Daily Temp
Design Location TMY Site Zane 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Jecksomille FL_JACKSONVILLE–INT 2 32 93 70 75 1281 49 Medium
BLOCKS
Number Name Area Volume
1 Blookt 1227 9816
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms In6I ID Finished Cooled Heated
1 tet Roor 658 5264 Yes 0 0 1 NO Yes Yes
2 2nd Floor 589 4552 No 4 2 1 Yes Yes Yes
FLOORS
# Floor Type Space Penmeter R-Value Area Te Wood Carpet
1 Slab-On-Grade Edge Irsulatio 19 Floor 126 it 0 658 it. — 0 0 1
ROOF
Roof Gable Roof Solar SA Emit Emil Deck Pilch
# Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Wood shingle 713 IF OM Medium 0.98 No 0.9 No 0 22.6
ATTIC
V # Type Ventilation Vent Ratio(I in) Mea RBS IRCC
1 Full sell Vented 150 6588' N N
CEILING
# Ceiling Type Space R-Value Area Framing Frac Truss Type
1 Under A6ic(Vented) 2rd Fear 30 658 R2 0.11 Wool
4/2812015 9:41 AM ErtergyGauge®USA-FWReS2010 Section 405.4.1 Compliant So%ware Page 2 of 5
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
1 N Exeric, Frame-Wood tat Floor 19 16 6 8 0 132.08' 0 0.125 0.7 0
—2 E Neighbor Frame-Wood let Floor 19 44 0 8 0 352.0 W 0 0.125 0.7 0
3 S Exterior Frame-Woo! 1st Floor 19 16 6 8 0 132.08' 0 0.125 0.7 0
4 W Exterior Frame-Wootl let Floor 19 8 11 8 0 71.38' 0 0.125 0.7 0
5 W Neighbor Frame-Wootl let Floor 19 31 2 8 0 249.38 0 0.125 0.7 0
_6 N Exteror Frame-Wootl 2nd Fkar 19 16 6 8 0 132.08' 0 0.125 0.7 0
E Neighbor Frame-Wootl 2nd Floor 19 31 2 8 0 249.3 IF 0 0.125 0.7 0
8 S Extenor Frame-Wood 2nd Floor 19 16 6 8 0 132.08' 0 0.125 0.7 0
9 W Neighbor Frame-Wood 2nd Floor 19 31 2 8 0 249.38' 0 0.125 0.7 0
DOORS
# OrM Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N Insulatetl let Floor None .46 3 8 248'
2 W Insulated 1st Floor None .46 3 8 248'
WINDOWS
Orientation shown is the entered.Proposed orientation.
/ Wall Overhang
V # One ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 N 1 Vinyl Doube(Cear) Vee 0.3 0.3 27.68' 680 in 180 in None None
2 S 3 Vinyl Doube((Ztear) yes 0.3 0.3 1558' 180 in i80 in None None
_ 3 N 6 Vinyl Double,(Cear) yes 0.3 0.3 27.68' i80 in 180 in None None
4 S 8 Vinyl Double(Gear) yes 0.3 0.3 27 6 W 1 8 0 in 1 it 0 in None Nara
INFILTRATION
is Scope Method SLA CFM 50 ELA EgIA ACH ACH 50
1 molehouse Best Guess .0005 1609.2 88.34 188.14 .474 9.8363
HEATING SYSTEM
# System Type Subtype Elgdency Capacity Block Duds
1 Electric Heat Pump None HSPF.8.7 24 kBrahr 1 sys#t
COOLING SYSTEM
is System Type Subtype EMcency, Capacity AlrFew SHR Bock Duce
1 Cenral Unit None SEER: 15.2524 kBSJhr 720 chn 0.75 1 sys#1
4@82015 9:41 AM EnergyGsuge®USA-FlaRes2010 Sectlm 405.4.1 Canplienl Software Page 3 of 5
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use Se1Pnt Consul
1 Electric Heat Pump 1sl Floor 4.5 50 gal 90 gal 1200eg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model ft Area Volume FEF
None None fl'
DUCTS
/ —Supply --Return— Alr CFM 25 CFM25 HVAC#
V # Location R-Value Ane Loralbn Area Leakage Type HerMler TOT OUT ON RLF Heal Cod
_ 1 Aft 6 142W AtIo 187M Default Leakage 20 Fbor (Defeuk) (Dekup) 1 1
TEMPERATURES
"namable`{%�xJ armostst:(7N ��]] D000 Calling Fans:�X] D0 [X7 ��l((]
eel Cooling l^I Jan 1X7 Feb LXJ Mar 0!1;r 09 Way 0 Jun ptl Juoll LXJ AugB �P t I Nov (%]Dec
Venting IIXI Jan [X1 Feb �I�Xl1 Mar I1�X�1 lI�X1I lX1 Jun IXI Jul lX1 Aug MS.
x Cot
TMnnostat Schedule: HERS2008Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 80
M 80 80 78 78 80 00 78 78 78 778 8 78 78 78 8
Cooling(VJEH) FM 80 80 80 80 7 78 8 78 7 78 8 70 78 78 78 78 78
Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68
PM 68 68 68 68 68 68 Be 68 68 68 68 68
Nesting(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68
PM 68 68 68 68 68 68 68 fib 68 68 68 fie
4/28/2015 9:41 AM EnsrgyGaugsO USA-FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5
FORM 405-10
Florida Code Compliance Checklist
Florida Department of Business and Professional Regulations
Residential Whole Building Performance Method
ADDRESS: 122 SANDY BEACH LN PERMIT#:
ATLANTIC BEACH, FL, 32233-
MANDATORY REQUIREMENTS SUMMARY-See individual code sections for full details.
COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK
Air leakage 402.4 To be caulked,gasketed,weatherstripped or otherwise sealed.
Recessed lighting IC-rated as meeting ASTM E 283.Windows and
doors=0.30 cfnVsq.ft.Testing or visual inspection required. Fireplaces: X
gasketed doors&outdoor combustion air. Must complete envelope
leakage report or visually verify Table 402.4.2.
Thermostat& 403.1 At least one thermostat shall be provided for each separate heating and
controls cooling system.Where forced-air furnace is primary system,
programmable thermostat is required. Heal pumps with supplemental X
electric heat must prevent supplemental heat when compressor can
meet the load.
Ducts 403.2.2 All ducts,air handlers,filter boxes and building cavities which form the
primary air containment passageways for air distribution systems shall
be considered ducts or plenum chambers, shall be constructed and
sealed in accordance with Section 503.2.7.2 of this code. X
403.3.3 Building framing cavities shall not be used as supply ducts.
Water heaters 403.4 Heat trap required for vertical pipe risers.Comply with efficiencies in
Table 403.4.3.2. Provide switch or clearly marked circuit breaker
(electric)o shutoff(gas).Circulating system pipes insulated to=R-2 X
+accessible manual OFF switch.
Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical
ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level.
No make-up air from attics,crawlspaces,garages or outdoors adjacent ` !
to pools or spas. �C
Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower(HP)of= 1
&Spas HP shall have the capability of operating at two or more speeds. Spas
and heated pools must have vapor-retardant covers or a liquid cover or
other means proven to reduce heat loss except if 70%of heat from
site-recovered energy. Of Aimer switch required. Gas heaters minimum
thermal efficiency-78%(82%after 4/16/13). Heat pump pool heaters
minimum COP=4.0.
Cooling/heating 403.6 Sizing calculation performed&attached. Minimum efficiencies per
Tables 503.2.3. Equipment efficiency verification required. Special
equipment occasion cooling or heating capacity requires separate system or X
variable capacity system. Electric heat>10kW must be divided into two
or more stages.
Ceilings/knee walls 405.2.1 R-19 space permitting. X
4/2812015 9:41 AM EnergyGauge USA-FlaRes2010 section 405.4.1 Compliant Software Page 5 of 5
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 53
The lower the EnergyPerformance Index,the more efficient the home.
122 SANDY BEACH LN,ATLANTIC BEACH, FL, 32233-
1. New construction or existing New(From Plans) 9, Well Types Insulation Area
2. Single family or muthple family Multifamily a.Frame-Woof,Common R=19.0 1100.00%2
b.Frame-Wootl,Exterior R=19.0 599.33%2
3. Number of units,ff multiple family 1 c.WA R= ft'
4. Number of Bedrooms 2 d.WA R= ft,
5. Is MIs a worst case? No 10.Ceiling Types Insulation Area
a.Under Arno(Vented) R=30.0 658.00 W
6. condition!floor area(W) 1227 It.WA R= M
7. Wntlovs' Description Area c.WA R= fl'
a. U-Factor. Dbl,U=0.30 98.17 fl 11.Duds R 2
e.Sup:Attic,Ret:ANc,AH:2nd Floor 1442
SHGC: SHGC=0.30
It. U-Factor WA fl2
SHGC: 12.Cooling systems Saluda Efficiency
c. U-Fador: WA %2 a.Central Unit 24.0 SEER:15.25
SHGC:
d. NIA
SHGC:: fl 13.Heating systems kBtWhr Efficiency
SHGC: a.Electric Heat Pump 24.0 HSPF:8.70
Area Weighted!Avere9e Overhang Depth: 2.404 %.
Area Weighted Average SHGC: 0300
8. Floor Types Insulation Area 14.Hot water systems
a.Electric Cep:50 gallonsa.slab-0n-Gretl8.00fl is Edge Insulation R=0.0 85F:4.5
b.WA R= ft2
c.NIA R= %2 It. Conservation features
None
15,Credits None
I certify that this home has complied with the Florida Energy Efficiency Code for BuildingBST
Construction through the above energy saving features which will be installed(or exceeded) �Gy� _ �rPG
in this home before final inspection. Otherwise,a new EPL Display Card will be completed
based on installed Code compliant featured: �, �•••• P
Builder Signature: �"7���✓ }�--C Date:
Address of New Home: 12,, Sw,.1y �lr.✓1 City/FL Zip: A.(-1.,.. 2c (�..-✓l Q'CGD WS.fpv`''�
h=1 3 t a 33
'Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient
mortgage(EEM)incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation,contact the Florida Building Commission's support
staff.
**Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation,if not DEFAULT.
EnergyGauge®USA-FlaRes2010 Secfion 405.4.1 Compliant software
TABLE 402.4.2
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Proied Name: OUADPLEx-UNITC Bilker Name: BEACHES HABITAT
Street: 122 SANDY BEACH LN PermitOffice: CITU OF ATLATNCI BEACH
City,State,Zip: ATLANTIC BEACH, FL,32233- Permit Number:
Owner: Junsdidbn: 261100
Design Location: FL,Jacksonwile
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier Exterior thermal envelope insulation for framed walls is installed in
substantial contact and continuous alignment with building envelope
air barrier.
Breaks or joints in the air barrier are filled or repaired.
Air-permeable insulation is not used as a sealing material. k
Air-permeable insulation is inside of an air barrier.
Ceilinglattic Air barrier in any dropped ceiling/soffil is substantially aligned with
insulation and any gaps are sealed.
Attic access(except unvented attic), knee wall door,or drop down
stair is sealed.
Walls Comers and headers are insulated. X
Junction of foundation and sill plate is sealed.
Windows and doors Space between window/doorjambs and framing is sealed. X
Rim joists Rim joists are insulated and include an air barrier. X
Floors (including Insulation is installed to maintain permanent contact with underside
above-garage and cantilevered of subficor decking. ��
floors) Air barrier is installed at any exposed edge of insulation.
Crawl space walls Insulation is permanently attached to walls.
Exposed earth in unvented crawl spaces is covered with Class I , r ,1
Avapor retarder with overlapping joints taped. N
Shafts,penetrations Duct shafts,utility penetrations, knee walls and flue shafts opening
to exterior or unconditioned space are sealed.
Narrow cavities Batts in narrow cavities are cut to fit,or narrow Cavities are filled by
sprayed/blown insulafion. )c
Garage separation Air sealing is provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures are air fight, IC rated,and sealed to drywall.
Exception—fixtures in conditioned space.
Plumbing and wiring Insulation is placed between outside and pipes. Batt insulation is cut
to fit around wiring and plumbing,or sprayed/blown insulation
extends behind pipina and wiring. X
Showerftub on exterior wall Showers and tubs on exterior walls have insulation and an air barrier
separating them from the exterior wall. k
Electrical/phone box on Air barrier extends behind boxes or air sealed-type boxes are
installed. K
Common wall Air barrier is installed in common wall between dwelling units. K
HVAC register boots HVAC register boots that penetrate building envelope are sealed to X
subfloor ordrywall.
Fire lace Fireplace walls include an air barrier.
EnergyGaugeV USA-FlaRes2010 Section 405.4.1 Compliant Software
wrightsoft Manual S Compliance Report Job Date: iQUAD4LEXa NSIDENNM-C
Entire House By: JLF
FLORIDA AIR SERVICE & ENGINEERING
IWHILDENRD3 PONTEVEDRE,FL3A1PWne:9R80}I6p6 Email FTEQENGINEERCOMVlit lVvvvWRTHFLORlD RC0M
Project Information
For: OUADPLEX-INSIDE UNIT-C, BEACHES HABITAT
122 SANDY BEACH LN,ATLANTIC BEACH, FL 32233
Cooling Equipment
Design Conditions
Outdoor design DB: 92.0°F Sensible gain: 19548 Btuh Entering coil DB: 76.3°F
Outdoor design WB: 78.0°F Latent gain: 2505 Btuh Entering mil WB: 63.2F
Indoor design DB: 75.0°F Total gain: 22052 Btuh
Indoor RH: 50% Estimated airflow: 800 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: CARRIER Model: 25HBC524+FX4DNF025
Actual airflow: 800 cfm
Sensible capacity: 10798 Btuh 55%of load
Latent capacity: 2625 Btuh 105%of load
Total capacity: 13423 Btuh 61%ofload SHR: 80%
Heating Equipment
Design Conditions
Outdoor design DB: 39.0°F Heat loss: 21126 Btuh Entering mil DB: 69.4°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: CARRIER Model: 25HBC524+FX4DNF025
Actual airflow: 800 cfm
Output capacity: 17780 Btuh 84%of load Capacity balance: 38 °F
Supplemental heat required: 3347 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip
Manufacturer: Model:
Actual airflow: 800 cfm
Output capacity: 5.2 kW 84%of load Temp.rise: 0 °F
The above equipment was selected in accordance with ACCA Manual S.
- M1I 4r-21¢25:10
carrMtsoftR -SuileDUni ...I M1313o.RSU1 WM
Pryer
..gM»fi HJACWFBIJPX-0URWNSIDE UNIT-C J.rup Cek=WE BuIWIng Fmtla , N
1Residential Plans Examin-r Review FormForm
RPER 1
•
for - D' •n (Loads, Equipment, 15 Mar 09
4W)N•y.Wdana
Header Information
Contractor: FLORIDA AIR SERVICE REQUIRED ATTACHMENTS ATTACHED
Mechanical license CAC1813923 Manual Jt Form(add supponing worksheets): Yes ® No C]
or Mi Form'(and supporting incremental Yes ❑ No C]
OEM performance date(heating,Goold ,blower): Yes I$I No ❑
Building plan R: Manual D Friction Rate WorksheetYes KI No ❑
Duct distribution sketch: Yes ® No
Home address(Street or LOM,Block,Subtlivision): 122 SANDY BEACH LN, Entire House
HVAC a ' a CALCULATION (IRC M1401.3)
Design Conditions Building Construction Infonnatinn
Winter Design Conditions Building
Outdoor tdmperalure: 39 T Orriennn°u i'w.a sWm,xnuildingg FFrrotfaccessN0rthh1
Irldoortempereture: 70 'F
Total Mal pass: 21126 BWh Numberofbedroams: 3
Conditioned floor area: 1227 ft'
Summer Design Conditions Number of occupants: 0
Outdoor tempendmir 92 'F
Indoortemperalure: 75 °F Windows Rol
Grains difference: 58 grAB 50%RH Eave overhang depth: 1,0 fl
Sensible heal gain: �g548 Both Internal shade: none
Latent Mat gain: 2505 BNh alna.,d,waac o•�oa va.
Total Mat gain 22052 Biuh Number of skylights: 0
EQUIPMENTHVAC • 1
Heating Equipment na1a (AphngEqu'nmpnt Data BIOWnr Data
E49KseMxPem SpIgASH P Eaui�menttype StildASHP Heating cin: 800
x. aewx.ac. 1r axan.,xrl P.,aw Cooling con: 800
Model: CARRIER Madel: CARRIER Static pressure: 0.S01n H2O
25HBC524aF%4DNF025 25HBC52aeFX<DNF025 r•n.rme.mm.l aaa p .—liar d..lan
Head output ce edty: ] pr. Btuh Total cooling capacity:
x.a mw =w•.Rx 1—..n-JZT dv&tBl tU 13423 Btuh
Sensible cooling capacity: 10798 Built
Aux.Mating output capacity: 17762 Binh Latent coaling capacity: 2625 BWh
TVAC DUCT DISTRIBUTION SYSTEM DESIGN fIRC RUGUI 1 )
Design unlearn 800 dm Longest supply dud: 377 it Duct Materials Usec
Equipment design ESP: 0,50 in H2O Longest datum dud: 0 fl TMnk dud:
Total device pressure losses: 0 In H2O Total eased.length(TELT: 35707 fl
Available static pressure(All 0.50 in H2O Frictionod�e.axp=aswiTstO.molO ii Branch dud: Round flex vinyl
I declare the load calculation.equipment,equipment selection and duct design ware rigorously parforioned bcsod on the building plad
listedabove I undenstrand the claims made on thl forded will be subject to review and verification
Contractor's printed name: J FERNANDEZ
Contractor's signature: J FERNANDEZ (E-SIGN) Date: 04/2015
jurisdictionReserved for County,Town Municipality or Authority having
'Home qualifies for M7 Form based--an Edition Checklist
+I+ wrightsoft Ri051-Suil,,Un.—...12010Ice.aa RSM JSA
W right5oftBuilding Analysis Job: DUADPLU-INSIDE UNIT-C
Date: 1112014
Entire House 6y: JLF
FLORIDA AIR SERVICE 8 ENGINEERING
150 WLDEN nD bit.PoWE VEDRE,FL 31081 PMne'.9OJd139898 Em .FMMNGINEER.COM VAa:VMMJ.NDRil L0fl1Q 4 RXW
Project Information
For: DUADPLEX-INSIDE UNIT-C, BEACHES HABITAT
122 SANDY BEACH LN,ATLANTIC BEACH,FL 32233
Design
Location: Indoor: Heating Cooling
Jacksonville Mayport Naval, FL, US Indoor temperature(°F) 70 75
Elevation: 16 It Design TD(°F) 31 17
Latitude: 30°N Relative humidity(%) 40 50
Outdoor: Heating Cooling Moisture difference(9011b) 15.7 58.2
Dry bulb(°F) 39 92 Infiltration:
Dailymnge(°F) - 15 ( 1 ) Method Simplified
Wat bulb(7) - 78 Construction quality Average
Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average)
Component BIuhW Btuh %ofload
Wells 2.7 1728 8.2
Glazing 46.9 10934 51.8
Doors 0 0 0
Ceilings 1.0 1217 5.8 -
Floors 0.9 1095 5.2
Infiltration 4.0 3504 16.6
Ducts 2649 12.5
Piping 0 0
Humidification 0 0
Ventilation 0 0
Adjustments 0
Total 1 211261 100.0
Component BWh4P Btuh %of load
Walls 1.4 911 4.7
Glazing 53.3 12426 83.6
Doors 0 0 0
Ceilings 1.7 2134 10.9
Floors 0 0 0
Infiltration 0.9 791 4.0
Ducts 3286 16.8
Ventilation 0 0
Internal gains 0 0
Blovier 0 0
Adjustments 0
Total1 1 195481 100.0
Latent Cooling Load=2505 Btuh
Overall U-value=0.145 BWhNP-°F
Data entries checked.
WFIQIILSOfCRqM-SufteO 11 Naim M1515.e0a RSU19651 1015Jpr-1B 10.15
10
Pep•1
Ar
..ahtw NVACWABIlUI-0UPl)INSIDE UMTL J.W Cai" Bali FmMM1ut N
wri htsoft Project Summary Job: UUADPLU-INSIDEUNR-C
Dat9 Entire House Byre: ,2 /101d
FLORIDA AIR SERVICE & ENGINEERING
IW HILDEN RD] .PONTE V DRE FL 3"81 PlmneW 28 9598 Email,FAECENGINEER COM Web:WEAN NORTWLORIQMR COM
Project Information
For: OUADPLEX-INSIDE UNIT-C, BEACHES HABITAT
122 SANDY BEACH LN,ATLANTIC BEACH, FL 32233
Notes:
Design Information
Weather: Jacksonville Maypod Naval,FL, US
Winter Design Conditions Summer Design Conditions
Outside db 39 °F Outside db 92 °F
Inside db 70 °F Inside db 75 °F
Design TO 31 °F Design TO 17 "F
Daily range L
Relative humidity 50
Moisture difference 58 gr/Ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 18478 Btuh Structure 16262 Btuh
Ducts 2649 Stub Ducts 3286 Stub
Central vent(0 cfm) 0 Stub Central vent(0 cfm) 0 Stub
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 21126 Btuh Use manufacturefs data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 19548 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 1 (Average) Structure 1674 Btuh
Duds 831 Btuh
Heating Cooling Central vent(0 cim) 0 Btuh
Area 1227 1227 Equipment latent load 2505 Stub
Wlume(R') 11043 11043
Air changes/hour 0.56 0.23 Equipment total load 22052 Btuh
Equiv.AVF(cfm) 103 42 Req.total capacity at 0.78 SHR 2.1 ton
Heating Equipment Summary Cooling Equipment Summary
Make CARRIER Make CARRIER
Trade 2.0 TON Trade 2.0 TON
Model 25HBC524 Cond 25HBC524
AHRI ref 3645571 Coil FX4DNF025
AHRI ref 3645571
Efficiency 8.7 HSPF Efficiency 15.25 SEER
Heating input Sensible cooling 18720 Btuh
Heating output 24000 Blur @ 47°F Latent cooling 5280 Stub
Temperature rise 27 F Total cooling 24000 Btuh
Actual air flow 800 cfm Actual air flow 800 cfm
Air flow factor 0.038 cfm/Btuh Air flow factor 0.041 cfm/Btuh
Static pressure 0.50 in H2O Static pressure 0.50 in H2O
Space thermostat Load sensible heat ratio 0.89
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
�j� I' wrightsoft' RpN-suneA uNveraal M1313.obe Rsm3551 881`�4,2*1025:10
�.G -aimmftWACHA9IJP -Qu N$10EUNl1.1.IUO Cak'MIB BUIWIn9Fmmb N ".1
AED Assessment Job: DUADPLEX4NSIDEUNR-L
wrightsoft Date: 12/2014
Entire House By: JLF
FLORIDA AIR SERVICE & ENGINEERING
150HILDENRD3CBPONEVEDRE,F132081Pl 9N 9695 EmII.FAECENGINEER,COMMb.VMVNORTHFLORIOMIn.COM
Project Information
For: DUADPLEX-INSIDE UNIT-C, BEACHES HABITAT
122 SANDY BEACH LN,ATLANTIC BEACH, FL 32233
Design
Location: Indoor: Heating Cooling
Jacksonville Maypod Naval, FL,US Indoor temperature('F) 70 75
Elevation: 18 It Design TD(°F) 31 17
Latitude: 30'N Relative humidity(%) 40 50
Outdoor: Heating Cooling Moisture difference(gr/Ib) 15.7 58.2
Dry bulb(*F) 39 92 Infiltration:
Dailyrange(°) - 15 ( L )
Nat bulb("F) 78
Wind speed(mph) 15.0 7.5
Test for Adequate Exposure Diversity
Fb*Georg load
w.
la,
u.
le
$.
fi
3.
8 9 10 11 12 13 1< 15 18 17 18 10 30
wfM
Maximum hourly glazing load exceeds average by 22.9%.
House has adequate exposure diversity (AED), based on AED limit of 30%.
AED excursion: 0 Btuh
wrl htsoff zplur„ae lozs:m
��TjF 9 RI9 M-SuMeA VMreru1201313.0.09 R3U135N ppet
/R•l.•� ...ghlw6HVACW8IJM-OUA N$lDEUNffC J.mP C -MJa Busdin9Fr lams. N
Component Constructions Job: GUADPLU41BIDEUNIT-C
wrightsoft p Date: 12no14
Entire House By: JLF
FLORIDA AIR SERVICE & ENGINEERING
150 HILDEN RD b8,PONTE VEDRE FL 33081 Prone:90082}9694 EmA:FAECENDINEER.COM VNE:'MN RTKLORIO R.COM
Project Information
For: DUADPLEX-INSIDE UNIT-C,BEACHES HABITAT
122 SANDY BEACH LN,ATLANTIC BEACH,FL 32233
Design
Location: Indoor: Heating Cooling
Jacksonville Maypon Naval,FL,US Indoor temperature(°F) 70 75
Elevation: 16 It Design TD(°F) 31 17
Latitude: 30"N Relative humidity(Y) 40 50
Outdoor: Heating Cooling Moisture difference(grAb) 15.7 58.2
Drybulb(°F) 39 92 Infiltration:
Dailyrange(°F) - 15 ( L ) Method Simplified
Wetbulb('F) - 78 Construction quality Average
Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average)
Construction descriptions Or Area U-value Insol R His HTM Loss Clg MTM Gain
R .1-F R°F.WF 4IUT` aun MM BM
Wells
12B-21gw:I'm wall,bdc 4"ext,r-11 cav ins.2"x4"wood fm,r-2 int bd n 589 0.086 13.0 2.67 1570 1.41 828
ins a 45 0.086 13.0 2.67 120 1.41 63
all 634 0.086 13.0 2.67 1690 1.41 891
Partitions
(none)
Windows
10Am:1 glazing,ratledive(1/4"only)glz,me no on,hm mat,114'thk, n 72 1.670 D 51.8 3727 27.6 1985
high rid pert:8 it overhang(8 fl window ht 6 it sep.)
to-c1 om:1 glazing,or glz,m8 no brit 1rm mat,1/8"ink.1 8 overhang(6 a 35 1.270 0 39.4 1378 93.5 3273
it window In,2 it sap.)
Doors
(none)
Callings
168-30ad:Attic ceiling,asphalt shingles root mat,r-31 root ins,r-30 cell n 1227 0.032 30.0 0.99 1217 1.74 2134
Ins
Floors
STA-vph:Bg Boor,heavy damp nil,on grade calm,vinyl 6r/nsh n 26 1.358 0 42.1 1095 0 0
Wf IltSoft' RI nl-
10:38:57
AM,('� 9 6 .l.Urcreree1201313.0.09R5U135N Patel
ighnon M/ACV4I1 -QU NSIDEUNIT-CMD.mp CW—MA Wlwnp Fr tfnns: N
Component Constructions Job: OUADPLU-INSIDEUNn-C
wrightsoft P Date: 12RO14
BATH2 By: JLF
FLORIDA AIR SERVICE & ENGINEERING
I WHILDEN RD 308,PONTEVEDRE,FL 32081 PMne:90082}95gg Emep:FMCENGINEERCOM N !,:YYNJ✓NORTHFLORIDPNRCOM
Project Information
For: QUADPLEX-INSIDE UNIT-C,BEACHES HABITAT
122 SANDY BEACH LN,ATLANTIC BEACH,FL 32233
Design
Location: Indoor: Heating Cooling
Jacksonville Maypon Naval,FL,US Indoor temperature(°F) 70 75
Elevation: 16 ft Design TD(°F) 31 17
Latitude: 30°N Relative humidity 1%) 40 50
Outdoor: Heating Cooling Moisture diference(grAb) 15.7 58.2
Drybulb CF) 39 92 Infiltration:
Dailyrange CF) - 15 ( L ) Method Simplified
Wet bulb(*F) - 78 Construction quality Average
Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average)
Construction descriptions Or Area U-value Insul R His HTM Loss Cls HW Gain
x se,,W.s W.-Fmen eenne awn aenire mn
Walls
(none)
Partitions
(none)
Windows
10A-m:1 glazing,refiedive(114'only)QV,me no brk trrn mat 1/4"thk, n 6 1.670 0 51.8 311 27.6 165
high rad pert:8 it overhang(8 it window In,6 I sep.)
Doors
(none)
Ceilings
16B-30zd.Attic ceiling,aspha8 shingles roof met r-31 root ins,r-30 tail n Be 0.032 30.0 0.99 95 1.74 167
ins
Floors
22A-Wh:Bs floor,heavy damp soil,on grade depth.Any]fir insh n 6 1.358 0 42.1 253 0 0
2m5Jp-2810:38:57
Wrightd:uft RgMSUXeA 11verw.1313.0.00 RSUI M64
Pees 2
-C� ...gM1Iwa HJPCV1aBIJAX-0UMINSICE UNT-GMD.mp Ctl—MJB BUXEIry FmMfecee: N
Component Constructions Job: OUADPLE%-INSIDE UNIT-C
wrightsOft P Date: 12/2014
BE02 By: JLF
FLORIDA AIR SERVICE & ENGINEERING
1WHILDENRD3re.POMEVEORE,FL3z081PMne:9118135898 E l:FPEGENGINEER.COMNb.w ..N WWLDRID R,COM
Project Information
For: DUADPLEX-INSIDE UNIT-C,BEACHES HABITAT
122 SANDY BEACH LN,ATLANTIC BEACH, FL 32233
Design
Location: Indoor: Heating Cooling
Jacksonville Maypon Naval, FL,US Indoor temperature(°F) 70 75
Elevation: 16 It Design TD(°F) 31 17
Latitude: 30'N Relative humidity(%) 40 50
Outdoor: Heating Cooling Moisture difference(grAb) 15.7 58.2
Drybulb(°F) 39 92 Infiltration:
Dailyrange(°F) - 15 ( L ) Method Simplified
Watbulb(°) - 78 Construction quality Average
Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average)
Construction descriptions Or AreaU-value Imod R the HTM Loss C1g HTM Gain
M ash,' ",lee e eve. BM
Walls
125-211w:F. all,blk 4"ext r-11 cav Ins,2'x4"wood fnn,r-2 int bd n 126 0.086 13.0 2.87 336 1.41 177
ins
Partitions
(none)
Windows
t0A-m:1 glazing,reflective(114'only)gU,mtl no brk fm mat,1/4'Alk, n 16 1.870 0 $1.8 828 27.6 441
high Md ped:8 It overhang(8 A window h1,6 fl esp.)
Doors
(none)
Ceilings
16B-30ad:Aflic ceiling,asphafl shingles roof met,r-31 roof ins,r-30 cell n 216 0.032 30.0 0.99 214 1.74 376
ins
Floors
(none)
. 201Ar-20m:asa
wrf htsOftRI m-Su Universal .8B v ppe
. mHRCNJPOUMNSIDE UTATGD.rup Calle-IB Build,Fnl 3
larva: N
Component Constructions Job: OUADPLEX4NSIDE UNIT-C
Wrlght5Oft P Date: 12=14
GREAT By: JLF
FLORIDA AIR SERVICE & ENGINEERING
150HILDENFOYMPONTEVEORE FL3Nsl PIwna:9462}9gge Emil'.FAECENGINEER.00MIMt'.%VwWNORTIiLORID R.COM
Project Information
For: QUADPLEX-INSIDE UNIT-C,BEACHES HABITAT
122 SANDY BEACH LN,ATLANTIC BEACH, FL 32233
Design
Location: Indoor: Heating Cooling
Jacksonville Maypon Naval,FL,US Indoor temperature(°F) 70 75
Elevation: 16 It Design TD CF) 31 17
Latitude: 30"N Relative humidity(%) 40 50
Outdoor: Heating Cooling Moisture difference(gr(b) 15.7 58.2
Drybulb CF) 39 92 Infiltration:
Dailyrange CF) - 15 ( L ) Method Simplified
Nktbulb(°F) - 78 Construction quality Average
Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average)
Construction descriptions Or Area U-value Insul R Htg HTM Loss Cie HTM Gain
I ranlr---F 1--E. Nnwr ewh aen.n• Inn
Walls
12B-2bw:I'm wall,bink 4-ext,El I cav ins,2 aC wood fire,r-2 as bel n 111 0,086 13.0 2.67 2% 1.41 156
ins a 45 0.086 13.0 2.67 120 1.41 63
all 156 0.086 13.0 2.67 416 1.41 219
Partitions
(none)
Windows
1 Act om:1 gazing,Gr gIE In no bink finer mat,1B'thk;1 8 overhang(6 a 35 1.270 0 39.4 1378 93.5 3273
ft window ht.2 8 sep.)
Doors
(none)
Ceilings
1813-30ad:ABic ceiling,asphalt shingles roof mat,r-31 roof Ins,E30 cell n 298 0.032 30.0 0.99 2% 1.74 518
ins
Floors
22A-vph:Bg floor,heavy damp soil,on grade depth,vinyl 8r fnsh n 12 1.358 0 42.1 505 0 0
Aft
HwrightsofY RphlSuilseunlaena12013130.WR6V1365r 2n1SApr-2610'.36'.57
AC'GiGa vq.4
...gMaoa HJACYVBIJA%-OUAOJN610E UNIT-LMO.rvO CMc=MJ6 BUIMnp fern)leas: N
Com onent Constructions Job: QUADPLEX-INSIDE UNIT-C
Wrlght50ft p Date: 12n014
BATH By: JLF
FLORIDA AIR SERVICE & ENGINEERING
150HILDENRD30e,P0WEVEDREFL32081 Phone:W 28 96% Email:FAEQENGINEER.00la~:awvviN0mWL0RID"R.00M
Project Information
For: QUADPLEX-INSIDE UNIT-C, BEACHES HABITAT
122 SANDY BEACH LN,ATLANTIC BEACH, FL 32233
Design Conditions
Location: Indoor: Heating Cooling
Jacksonville Maryport Naval, FL, US Indoor temperature(°F) 70 75
Elevation: 16 ft Design TD(°F) 31 17
Latitude: 30°N Relative humidity(%) 40 50
Outdoor: Heating Cooling Moisture differenoe(grAb) 15.7 58.2
Dry bulb(°F) 39 92 Infiltration:
Dailyrange(°F7 - 15 ( L ) Method Simplified
Wetbulb('F) - 78 Construction quality Average
Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average)
Construction descriptions Or Area U-value lwul R Htg HTM Loss Clg HTM Gain
I EYNM1'F R-'F9t, hm MM ant
Walls
1213-21mw:Fm wall,bark V ext,r-11 Cav ins,2?4'wood Inn,r-2 int bad n 90 0.086 13.0 2.67 240 1.41 127
ins
Partitions
(none)
Windows
10A-m:1 glazing,reflective(1/P only)gb,m0 no brk fnn mat,1/4"Mk, n 20 1.670 0 51.8 1035 27.6 561
high Md ped;6 ft overhang(8 It window ht,6I sep.)
Doors
(none)
Ceilings
16B-30ad:Altic ceiling,asphalt shingles roof mat,r-31 root ins,rd0 cell n 119 0.032 30.0 0.99 118 1.74 207
ins
Floors
(none)
wrlght5l g zolsAvr-ze 10 3e.57
Ri M-SUXeA UNrx>Y z01313.a0B RSU1355> M57
...IOhaOf WACaw8lJa%-QUAD-INSIDE UNIT{-I.ID.rvp Call•MA BuWIIq Front from N
Component Constructions Job: QUADPLE%JNSIDE UNIT-C
wrightsoft P Data: 1212014
MECH By: JLF
FLORIDA AIR SERVICE & ENGINEERING
150HILDENRD308,PONTEVEDREFL3209111aarm 9048239596 Email'.FAECENGINEER.COMiNam V NORTHFLORIDANRCDM
Project Information
For: DUADPLEX-INSIDE UNIT-C,BEACHES HABITAT
122 SANDY BEACH LN,ATLANTIC BEACH,FL 32233
Design
Location: Indoor: Heating Cooling
Jacksonville Mayport Naval, FL,US Indoor temperature('F) 70 75
Elevation: 16 8 Design TD(°F) 31 17
Latitude: 30'N Relative humidity(%) 40 50
Outdoor: Heating Cooling Moisture differenos(grAb) 15.7 58.2
Drybulb(°F) 39 92 Infiltration:
Dailyrange(°F) - 15 ( L ) Method Simplified
Watbulb(`F) - 78 Construction quality Average
Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average)
Construction descriptions Or Area U-value Insul R Htg HTM Loss Cls HTM Gain
T Ma'-'F R-'F.H1Ii &IiT' BbF 6Mi1P BaF
Walls
1213-21on:F.wall,brk 4-eat,r-11 cav ins,2"x4'wood Om,r-2 int bd n 8 0.086 13.0 2.67 21 1.41 11
Ins
Partitions
(none)
Windows
(none)
Doors
(none)
Ceilings
16B-Mad:AtBc ceiling,asphalt shingles roof mat,r-31 root ins,r-30 cell n 66 0.032 30.0 0.99 65 1.74 115
ins
Floors
22A-vph:Bg floor,heavy damp soil,on graft depth,vinyl fir loan n 8 1.358 0 42.1 337 0 0
Wri htsoft' 2o1s.APr-za 10:39.7
C RiNSIDE iJNIT- vD.na1301313l Rnd135N ppa8
� ...gMaoa HVACWPBIJNIAUPD1N51DE UNIT-CMO.np LYc=MJe BUHin9 From fames: N
Component Constructions Job: DUADPLEIl4NslDEUNm-C
wfightSOft P Date: 1212014
BED3 By: JLF
FLORIDA AIR SERVICE & ENGINEERING
150 HILDFN RD Jae,PON1E VEDRE.FL 12081 Phone:00 2 9698 EmN:FREGENGINEER.COM NM:%WAvI,0RTWLORKW,MR.COM
Project Information
For: DUADPLEX-INSIDE UNIT-C. BEACHES HABITAT
122 SANDY BEACH LN,ATLANTIC BEACH, FL 32233
Design Conditions
Location: Indoor: Heating Cooling
Jacksonville Mayport Naval,FL,US Indoor temperature(°F) 70 75
Elevation: 16 It Design TD(°F) 31 17
Latitude: 30°N Relative humidity(%) 40 50
Outdoor: Heating Cooling Moisture diference(grfib) 15.7 58.2
Drybulb(°F) 39 92 Infiltration:
Dailyrenge CF) - 15 ( L ) Method Simplified
Netbulb(°F) - 78 Construction quality Average
Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average)
Construction descriptions Or Area U-value Insul R Htg HTM Loss Lig HTM Gain
Are:
mn W-r r.F.snw mn,re awn em,e am
Walls
12B-21bw:F.vi brk 4'e*.r-11 wv ins,Ta4"wood Mn,r-2 int led n 127 0.086 13D 2.67 339 1,41 179
ins
Partitions
(none)
Windows
t0A-m:1 glazing,reflective(1/4"only)glz,m8 no bit Mn mel,1M"Mk, n 15 1.670 0 51.8 777 27.6 414
high Ad ped,86 ov m.mg(8 it window ht,6 I sept
Doors
(none)
Ceilings
16B-30ad:Aaic osilirp,asphalt shingles roof met,r-31 roof ins,r-3D sail n 222 0.032 30.0 0 89 220 1.74 386
Ina
Floors
(none)
wrl htsoft mtsspr-m1o:Je:s7
Z RINSIDEU IT � D.no mlJl We Ron pp•i
..gnlwa HVPCVWBIJAC-OUPAINSIDE UNITf.MD.� C•k•MJB &iMlnp F—t lave: N
Component Constructions Job: OUADPLEX-INSIOE UNIT-C
wrightsoft P Date: 1=014
KITCHEN By: JLF
FLORIDA AIR SERVICE & ENGINEERING
150 HILDEN RD.8.POME VE E.FL 32081 Ph- 901-e1 %% Emeil'.FAECENGINEER.COM Kbb:R NORTHFLOPJDN R.COM
roject Information
For: QUADPLEX-INSIDE UNIT-C, BEACHES HABITAT
122 SANDY BEACH LN,ATLANTIC BEACH, FL 32233
Design
Location: Indoor: Heating Cooling
Jacksonville Maypon Naval, FL,US Indoor temperature ff) 70 75
Elevation: 16 It Design TD(°F) 31 17
Latitude: 30°N Relative humidity(%) 40 50
Outdoor: Heating Cooling Moisture difference(grAb) 15.7 58.2
Drybulb(°F) 39 92 Infiltration:
Dailymnge(°) - 15 ( L ) Method Simplified
Watbulb(`F) - 78 Construction quality Average
Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average)
Construction descriptions Or Area U-value Insul R Htg HTM Loss Cis HTM Gain
T a ,e-T R--F. 9an1' 6be PMM BM
Walls
12B-2bw:Fm well,brk 4"to,r-11 cav ins,2-W wood frm,r-2 int b0 in 127 0.086 13.0 2.67 339 tAt 179
ins
Partitions
(none)
Windows
1 OA-m:1 glazing,reflective(1/4"only)gb,m8 no bIk Inn mat, 114-ink, in 15 1.670 0 51.8 777 27.6 414
high rac1 per,8 8 overhang Is It wind.M,6 I sap.)
Doors
(none)
Ceilings
16B-30aU:Aaic ceiling,asphalt shingles roof mel,r-31 roof ins,r-30 cell n 210 0.032 30.0 0.99 208 1.74 385
Ins
Floors
(none)
2015-ror-2910 SK57
wright'SOft Ri,MSUXeA UNeerrel M101 om)RSU135M ".8
.IphYpfi WACULA WM-OUP INSIDEUMTL D.mp Cele-MJ8 Wk ingF Mfeuv: N
Duct System Summary Job. DUADPLEX-0UTSIDEUNI...
W rlghtsoft Date; 1212014
Entire House By: JLF
FLORIDA AIR SERVICE & ENGINEERING
1WNIL0ENRD=.Fa0WEVEDRE,FL32081PIwne:W a-a IB9 EmeY:FAE®ENGINEER. 0myAmb~a0RTWL0WDMIRC0M
Project Information
For: OUADPLEX-OUTSIDE UNIT-D, BEACHES HABITAT
122 SANDY BEACH LN,ATLANTIC BEACH,FL 32233
Heating Cooling
External static pressure 0.50 in H2O 0.50 in H2O
Pressure losses 0 in H2O 0 in H2O
Available static pressure 0.50 in H2O 0.50 in H2O
Supply/return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O
Lowestfiction rate 0.500 iN10011 0.500 kW00R
Actual air flow 800 dm 800 dm
Total effective length(TEL) 377 ft
Supply Branch Detail . •
Design Htg CI9 Design Diem H x W Dud Actual Ftg.Egv
Name (Btuh) (cfm) (cfm) FR (n) (in) Mad Ln(ft) Ln(ft) Trunk
MECH h 541 27 10 0.500 4.0 Oxo VIFx 307.0 70.0
MTM It 841 33 34 0.500 4.0 0x0 VIFx 307.0 70.0
MEED h 3565 169 153 0.500 7.0 0x0 VIFx 307.0 70.0
BEDS h 2302 116 95 0.500 6.0 Oxo VIFx 307.0 70.0
WCHFN It 2348 118 102 0.500 6.0 Oxo VIFx 307.0 70.0
eED2 It 2311 116 97 0.500 6.0 Dx0 VIFx 307.0 70.0
GREAT c 2151 85 117 0.500 6.0 Oxo VIFx 307.0 70.0
GREAT-A c 2151 85 117 0.500 6.0 Oxo VIFx 307.0 70.0
BATH+ c 148 6 14 0.500 4.0 Oxo VIFx 307.0 70.0
MV4c It 530 14 7 0.500 4.0 Oxo VIFx 307.0 70.0
Wn hL50Tt' 1U1sMarvU314:r1:g1
rJ RIpMSupse UMpxta1201313.0.09 RSU13554 Pagel
ktk ..ghtsaaWACUNMI -QI UTSIDEUMTh D.mp CM[-MA BWnp Frvnllecx: N
AMICERTIFIED"
Certificate of Product Ratings
AHRI Certified Reference Number: 3645571 Date: 4/27/2015
Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source
Outdoor Unit Model Number: 25HBC524A-30
Indoor Unit Model Number: FX4DNF025
Manufacturer: CARRIER AIR CONDITIONING
Trade/Brand name: CARRIER
Series name: COMFORT 13 PURON HP
Manufacturer responsible for the rating of this system combination is CARRIER AIR CONDITIONING
Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source
Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third
parry testing:
Cooling Capacity(Btuh): 24000
EER Rating(Cooling): 12.00'
SEER Rating(Cooling): 15.25
Heating Capacity(Btuh)@ 47 F: 24000
Region IV HSPF Rating(Heating): 8.70
Heating Capacity(Btuh)@ 17 F: 14700
'RnM1ge Mlwsa by an aslalsk I'I MEIrsb a Munrary rent gprevquaN Wdished dela,unlea[acw„pania]MN a WAS,wh,cb'rds ates as involuntary renam
DISCLAIMER
AHRI do.not endo..the produtlfs)listed on this CertMcale and makes no representations,ovembe les or guarantees as to,and assumes no msponsamillty for,
Me producHp listed on MN Certificate.AHRI bronch s disclaims all liablllryfor damages of any kind arising old of the use or performance of the produmis),or the
meamminal.Xeratlon of data listed on this Certificate.Certified ratings are valid only for models and configuration.listed In the
directory at www.ahrldl rectory.org,
TERMS AND CONDITIONS
Thl.Certificate and N.cormnis are proptletary products of AHRI.Thla CeM1Mcam shell only be used for IndlAdual,personal and
confideentered tial am*reh.nceer dataea The minima of ifi C.rtM[ed may not,si whole or In part,be reproelf for copied:a MAW uai,
entered Imo a computer dMebefa;w%M1erMae Nlllzed,In any tOlm or assistant or by my means,ea<pl for the uwrs IndlNdual, JUN
pnwnaland E VERIFICATION
reemTION cera AIRMWEllex NIxSA E
CERTIFICATE for the Model Chad!
•RFFRISERMp tattin UlE
The eartar informationforthe medNCXedc this Number
an ified at abihMe certificates
[Ikkon'Verlly cmtlllcate'link make li&boner"
endhittli Ne AHRI .and the
Reference Humberand the ted onwhich Ne certM[aLL wm bwod, w`
which IS listed above.end iM GM1M[Me No.,wNkh Is listed al banpn dgNL -
02014 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: '3074613161910%%