Loading...
138 SANDY BEACH LN - ENERGY FILE Ci' 7Y FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: TRIPLEX-UNIT-C Builder Name: BEACHES HABITAT Street: 138 SANDY BEACH LN Permit Office: CITY_OF ATLANTIC BEACH City,State,Zip: ATLANTIC BEACH .FL,32233- Permit Number: /,7 .S FA T- /3-9O Owner: Jurisdiction: 261100 Design Location: FL,Jacksonville 1. New construction or existing New(From Plans) 9. Wall Types(1637.3 sqft.) Insulation Area 2. Single family or multiple family Multi-family a.Frame-Wood,Exterior R=19.0 1138.70 ft2 b. Frame-Wood,Common R=19.0 498.67 ft' 3. Number of units,if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 3 d.N/A R= ft' 5. Is this a worst case? No 10.Ceiling Types (572.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 572.00 ft 6. Conditioned floor area above grade(ft') 1140 b.N/A R= ft' Conditioned floor area below grade(ft') 0 c. N/A R= ft2 11.Ducts R ft' 7. Windows(130.1 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:2nd Floor 6 142 a. U-Factor: Dbl,U=0.30 130.11 ft' SHGC: SHGC=0.30 b. U-Factor: N/A ft' 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 24.0 SEER:15.25 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a. Electric Heat Pump 24.0 HSPF:8.70 SHGC: Area Weighted Average Overhang Depth: 3.338 ft. Area Weighted Average SHGC: 0.300 14.Hot water systems 8. Floor Types (572.0 sqft.) Insulation Area a. Electric Cap:50 gallons EF:4.500 a.Slab-On-Grade Edge Insulation R=0.0 572.00 ft' b. Conservation features b.N/A R= ft2 None c. N/A R= ft2 15.Credits None Glass/Floor Area: 0.114 Total Proposed Modified Loads: 15.18 PASS Total Standard Reference Loads: 29.31 I hereby certify that the plans and specifications covered by Review of the plans and •.••''FINE STgr'•. this calculation are in compliance with the Florida Energy specifications covered by this '1• n:. ,Fp,6•;: Code. calculation indicates compliance � ,,, . ..�' e with the Florida Energy Code. 1 :'u,,,, - .,:.... =',:�0 PREPARED BY: J FERNANDEZ _ Before construction is completed i'- 04/2015 ec : i, b � _ ip :: DATE: this building will be inspected for _ r , ,a . compliance with Section 553.908 .`.• ' I hereby certify that this building s designed, is in compliance Florida Statutes. '; ',c • with the Florida Energy Code. 9- 9 com p .• .,•.nD yyE'i ) •• OWNER/AGENT_ -., _ BUILDING OFFICIAL: DATE: S'J 2-1 //1---- DATE: - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist 4/28/2015 11:54 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 5 PROJECT Title: TRIPLEX-UNIT-C Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1140 Lot# Owner: Total Stories: 2 Block/SubDivision: County Seat #of Units: 1 Worst Case: No PlatBook: Book 108-n,page 345 Builder Name: BEACHES HABITAT Rotate Angle: 270 Street: 138 SANDY BEACH LN Permit Office: CITY OF ATLANTIC BEACH Cross Ventilation: No County: DUVAL Jurisdiction: 261100 Whole House Fan: No City,State,Zip: ATLANTIC BEACH, Family Type: Multi-family FL, 32233- New/Existing: New(From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Jacksonville FL_JACKSONVILLE INT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume 1 Block/ 1140 9120 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated 1 1st Floor 568 4544 Yes 0 1 1 No Yes Yes 2 2nd Floor 572 4576 No 4 2 1 Yes Yes Yes FLOORS V # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio 1st Floor 126 ft 0 572 ft2 — 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Wood shingle 620 ft' 0 ft2 Medium 0.98 No 0.9 No 0 22.6 / ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 572 ft' N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type 1 Under Attic(Vented) 2nd Floor 30 572 ft2 0.11 Wood 4/28/2015 11:54 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5 WALLS / Adjacent Cavity Width Height Sheathing Framing Solar Below V 8 Omt To v1/all Type Space R-Value Ft In Ft In Area R-Value Frartion Abcgr Grade°A 1 N=>W Exterior Frame-Wood 1st Floor 19 20 0 8 0 160.0 ft2 0 0.125 0.7 0 - 2 E=>N Exterior Frame-Wood 1st Floor 19 31 2 8 0 249.3 ft2 0 0.125 0.7 0 - 3 S=>E Exterior Frame-Wood 1st Floor 19 20 0 8 0 160.0 ft2 0 0.125 0.7 0 - 4 W=>S Neighbor Frame-Wood 1st Floor 19 31 2 8 0 249.3 ft2 0 0.125 0.7 0 - 5 N=>W Exterior Frame-Wood 2nd Floor 19 20 0 8 0 160.0 ft2 0 0.125 0.7 0 6 E=>N Exterior Frame-Wood 2nd Floor 19 31 2 8 0 249.3 ft2 0 0.125 0.7 0 7 S=>E Exterior Frame-Wood 2nd Floor 19 20 0 8 0 160.0 ft2 0 0.125 0.7 0 8 W=>S Neighbor Frame-Wood 2nd Floor 19 31 2 8 0 249.3 ft2 0 0.125 0.7 0 DOORS V # Omt Door Type Space Storms U-Value Ft Width In FHeightln Area 1 N=>W Insulated 1st Floor None .46 3 8 24 ft2 2 S=>E Insulated 1st Floor None .46 3 8 24 ft2 WINDOWS Orientation shown is the entered orientation(=>)changed to As Built(rotated 270 degrees). Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N=>W 1 Vinyl Double(Clear) Yes 0.3 0.3 27.6 ft2 6 ft 0 in 1 ft 0 in None None 2 E=>N 2 Vinyl Double(Clear) Yes 0.3 0.3 10.3 ft2 1 ft 0 in 1 ft 0 in None None 3 E=>N 2 Vinyl Double(Clear) Yes 0.3 0.3 6.0 ft2 1 ft 0 in 1 ft 0 in None None 4 S=>E 3 Vinyl Double(Clear) Yes 0.3 0.3 4.0 ft2 8 ft 2 in 1 ft 0 in None None 5 N=>W 5 Vinyl Double(Clear) Yes 0.3 0.3 27.6 ft2 6 ft 0 in 1 ft 0 in None None 6 E=>N 6 Vinyl Double(Clear) Yes 0.3 0.3 10.3 ft2 1 ft 0 in 1 ft 0 in None None 7 E=>N 6 Vinyl Double(Clear) Yes 0.3 0.3 13.3 ft2 1 ft 0 in 1 ft 0 in None None 8 S=>E 7 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 1 ft 0 in 1 ft 0 in None None 9 S=>E 7 Vinyl Double(Clear) Yes 0.3 0.3 15.5 ft2 1 ft 0 in 1 ft 0 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Best Guess .0005 1495.1 82.08 154.36 .474 9.8363 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.7 24 kBtu/hr 1 sys#1 4/28/2015 11:54 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER: 15.25 24 kBtu/hr 720 cfm 0.75 1 sys#1 HOT WATER SYSTEM ✓ # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Heat Pump 1st Floor 4.5 50 gal 90 gal 120 deg None SOLAR HOT WATER SYSTEM V FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft' DUCTS V/ --Supply-- —Return— Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 142 ft2 Attic 187 ft2 Default Leakage 2nd Floor (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:N Ceiling Fans: Cooling XI Jan ri Feb X Mar 'X Apr X May [X Jun 'X Jul 'X Aug X Sep [X Oct 'X Nov X Dec Heating X�Jan Feb X�Mar X�Apr �X�May [X�Jun X�Jul X�Aug f X�Sep [X�Oct X Nov X Dec Venting X Jan Feb X Mar X Apr X]]]May [X Jun X Jul X Aug [X Sep [X Oct X Nov X Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 4/28/2015 11:54 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: 138 SANDY BEACH LN PERMIT#: ATLANTIC BEACH, FL, 32233- MANDATORY REQUIREMENTS SUMMARY -See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC-rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: X gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat& 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced-air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental X electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and X sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff(gas). Circulating system pipes insulated to = R-2 X +accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics. crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower(HP) of= 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor-retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site-recovered energy. Off/timer switch required. Gas heaters minimum L/1 thermal efficiency=78% (82% after 4/16/13). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed &attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or X variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. X 4/28/2015 11:54 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 52 The lower the EnergyPerformance Index, the more efficient the home. 138 SANDY BEACH LN, ATLANTIC BEACH, FL, 32233- 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Multi-family a.Frame-Wood,Exterior R=19.0 1138.70 ft= b. Frame-Wood,Common R=19.0 498.67 ft 3. Number of units,if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types Insulation Area a. Under Attic(Vented) R=30.0 572.00 ft 6. Conditioned floor area(ft') 1140 b. N/A R= ft' 7. Windows** Description Area c.N/A R= ft' a. U-Factor: Dbl,U=0.30 130.11 ft' 11.Ducts R ft a. Sup:Attic, Ret:Attic,AH:2nd Floor 6 142 SHGC: SHGC=0.30 b. U-Factor: N/A ft' SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft' a.Central Unit 24.0 SEER:15.25 SHGC: d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 24.0 HSPF:8.70 Area Weighted Average Overhang Depth: 3.338 ft. Area Weighted Average SHGC: 0.300 8. Floor Types Insulation Area 14.Hot water systems a.Slab-On-Grade Edge Insulation R=0.0 572.00 ft' a. Electric Cap:50 gallons EF:4.5 b.N/A R= ft' c. N/A R= ft2 b. Conservation features None 15.Credits None I certify that this home has complied with the Florida Energy Efficiency Code for Building ••°{HEST •`'• Construction through the above energy saving features which will be installed (or exceeded) �F.- 9r0•. in this home before final inspection. Otherwise, a new EPL Display Card will be completed •k3'; • based on installed Code compliant features. '-:',"i,, ",, ::< „�o: 1 ., t Builder Signature: -)<.LA,i ■ L Date: 0 1 /i t' 0 _1 ', e, v . a Address of New Home: 1 3>s- (J a_ 1-a y.� City/FL Zip: ,4-'/4,;�, rte,'...- •.'•' *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software TABLE 402.4.2 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: TRIPLEX-UNIT-C Builder Name: BEACHES HABITAT Street: 138 SANDY BEACH LN Permit Office: CITY OF ATLANTIC BEACH City,State,Zip: ATLANTIC BEACH ,FL.32233- Permit Number: Owner: Jurisdiction: 261100 Design Location: FL,Jacksonville COMPONENT CRITERIA CHECK Air barrier and thermal barrier Exterior thermal envelope insulation for framed walls is installed in substantial contact and continuous alignment with building envelope air barrier. Breaks or joints in the air barrier are filled or repaired. Air-permeable insulation is not used as a sealing material. Air-permeable insulation is inside of an air barrier. Ceiling/attic Air barrier in any dropped ceiling/soffit is substantially aligned with insulation and any gaps are sealed. Attic access (except unvented attic), knee wall door, or drop down stair is sealed. Walls Corners and headers are insulated. X Junction of foundation and sill plate is sealed. Windows and doors Space between window/door jambs and framing is sealed. Rim joists Rim joists are insulated and include an air barrier. X Floors (including Insulation is installed to maintain permanent contact with underside above-garage and cantilevered of subfloor decking. floors) Air barrier is installed at any exposed edge of insulation. Crawl space walls Insulation is permanently attached to walls. Exposed earth in unvented crawl spaces is covered with Class I �V vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, knee walls and flue shafts opening to exterior or unconditioned space are sealed. Narrow cavities Batts in narrow cavities are cut to fit, or narrow cavities are filled by sprayed/blown insulation. __ Garage separation Air sealing is provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures are air tight, IC rated, and sealed to drywall. Exception—fixtures in conditioned space. Plumbing and wiring Insulation is placed between outside and pipes. Batt insulation is cut to fit around wiring and plumbing, or sprayed/blown insulation extends behind piping and wiring. L-- Shower/tub on exterior wall Showers and tubs on exterior walls have insulation and an air barrier separating them from the exterior wall. (-- Electrical/phone box on Air barrier extends behind boxes or air sealed-type boxes are installed. Common wall Air barrier is installed in common wall between dwelling units. HVAC register boots HVAC register boots that penetrate building envelope are sealed to subfloor or drywall. X Fireplace Fireplace walls include an air barrier. /0/1 EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Manual S Compliance Report Job: HABIJAX-TRIPLEX-UNIT-... + - wrightsoft Date: 02/2015 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308.PONTE VEDRE,FL 32081 Phone:904-823-9698 EmaM:FAECENGINEER.COM Web.WWW.NORTHFLORIDAAIR.COM Project Information For: HABIJAX-TRIPLEX-UNIT-C-MJ, BEACHES HABITAT 138 SANDY BEACH LN,ATLANTIC BEACH, FL 32233 Cooling Equipment Design Conditions Outdoor design DB: 92.0°F Sensible gain: 17799 Btuh Entering coil DB: 76.2°F Outdoor design WB: 78.0°F Latent gain: 2383 Btuh Entering coil WB: 63.2°F Indoor design DB: 75.0°F Total gain: 20182 Btuh Indoor RH: 50% Estimated airflow: 800 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: CARRIER Model: 25HBC524+FX4DNF025 Actual airflow: 800 cfm Sensible capacity: 11160 Btuh 63%of load Latent capacity: 2601 Btuh 109%of load Total capacity: 13762 Btuh 68%of load SHR: 81% Heating Equipment Design Conditions Outdoor design DB: 39.0°F Heat loss: 21760 Btuh Entering coil DB: 69.5°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: CARRIER Model: 25HBC524+FX4DNF025 Actual airflow: 800 cfm Output capacity: 17775 Btuh 82%of load Capacity balance: 39 °F Supplemental heat required: 3986 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 800 cfm Output capacity: 5.2 kW 82%of load Temp. rise: 0 °F The above equipment was selected in accordance with ACCA Manual S. 2015-Apr-28 12:02:25 wrightsoft Right-Suite®Universal 2013 13.0.09 RSU1 3554 Page 1 /r ...s\wrightsoft HVAC\HABIJAX-TRIPLEX-UNIT-C-MJ.rup Calc=MJ8 Building Front faces: W Residential Plans Examiner Review Form Form RPER 1 ACCk. for HVAC System Design (Loads, Equipment. Ducts) 15Mar09 Ar tinl'rroCixt+iM.h Mwra Header Information Contractor: FLORIDA AIR SERVICE REQUIRED ATTACHMENTS ATTACHED Manual J1 Form(and supporting worksheets): Yes ❑ No ❑ Mechanical license: CAC1813 92 3 or MJ1AE Form'(and supporting worksheets): Yes El No ❑ OEM performance data(heating,cooling,blower): Yes ❑ No ❑ Building plan#: Manual D Friction Rate Worksheet: Yes El No ❑ Duct distribution sketch: Yes ❑ No ❑ Home address(Street or Lot#,Block,Subdivision): 110 SANDY BEACH LN, Entire House HVAC LOAD CALCULATION (IRC M1401.3) Design_Canditions Building Construction Information Winter Design Conditions Building Outdoor temperature: 39 `F Orientation: Building Front faces West Indoor temperature: 70 °F North,East,West,South,Northeast,Northwest,Southeast,Southwest Total heat loss: 21760 Btuh Number of bedrooms: 3 Conditioned floor area 1140 ft' Summer Design Conditions Number of occupants: 0 Outdoor temperature: 92 °F Indoor temperature: 75 °F Windows Roo' Grains difference: 58 gr/lb @50% RH Eave overhang depth: 1.0 ft Sensible heat gain: 17799 Btuh Internal shade: none Esve Latent heat gain: 2383 Btuh Blinds,drapes,etc. Depth Wirral,. Total heat gain: 20182 Btuh Number of skylights: 0 HVAC EQUIPMENT SELECTION (IRC M1401.3) Heating Fquipment Data Cooling Fquipment Data Blower Data Ec,uipment t'pe: Split ASHP E�uioment type: Split ASHP Heating cfm: 800 urnace,Hea pump,Boiler,etc. it onditloner,Heat pump,etc. Cooling cfm: 800 Model: CARRIER Model: CARRIER Static pressure: 0.50 in H2O 25HBC524+FX4DNF025 25HBC524+FX4DNF025 Fan's rated external static pressure for design airflow Heating output capacity: 7775 Btuh Total cooling capacity: 13762 Btuh Heat pumps-capac ty at winter design out oor conditions Sensible cooling capacity: 11160 Btuh Aux.heating output capacity. 17762 Btuh Latent cooling capacity: 2601 Btuh HVAC DUCT DISTRIBUTION SYSTEM DESIGN (IRC M1601.1) Design airflow: 800 cfm Longest supply duct: 377 ft Duct Materials Used Equipment design ESP: 0.50 in H2O Longest return duct: 0 ft Trunk duct: Total device pressure losses: 0 in H2O Total effective length(TEL): 377 ft Available static pressure(ASP): 0.50 in H2O Friction rate: 0( 0 in/100ft Branch duct: Round flex vinyl Friction Rate=ASP,(TELL),' I declare the load calculation.equipment. equipment selection and duct design were rigorously performed based on the building plan listed above. I understand the claims made on these forms will be subject to review and verification. Contractor's printed name: J FERNANDEZ Contractor's signature: J FERNANDEZ (E-SIGN) Date: 04/2 015 Reserved for County. Town Municipality or Authority having jurisdiction use. 'Home qualifies for MJ1AE Form based on Abridged Edition Checklist -+{+- wrightsoft Right-Suite®Universal 2013 13.0.09 RSU13554 Buildin Anal $I$ Job: HABIJAX-TRIPLEX-UNIT-... 4 wrightsoft 9 y Date: 02/2015 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAEOENGINEER.COM Web:WVVW.NORTHFLORIDAAIR.COM Pro'ect Information For: HABIJAX-TRIPLEX-UNIT-C-MJ, BEACHES HABITAT 138 SANDY BEACH LN,ATLANTIC BEACH, FL 32233 Desi• n Conditions Location: Indoor: Heating Cooling Jacksonville Mayport Naval, FL, US Indoor temperature (°F) 70 75 Elevation: 16 ft Design TD (°F) 31 17 Latitude: 30°N Relative humidity(%) 40 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 15.7 58.2 Dry bulb CF) 39 92 Infiltration: Dailyrange (°F) - 15 ( 1 ) Method Simplified 'A t bulb(°F) - 78 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average) Heatin• Component Btu Mt' Btuh %of load Walls 2.7 1728 7.9 Glazing 48.3 11582 53.2 Doors 0 0 0 r_- Ceilings 1.0 1131 5.2 Floors 1.3 1431 6.6 Infiltration 3.7 3304 15.2 Ducts 2585 11.9 --• Piping 0 0 Humidification 0 0 °'- Ventilation 0 0 Adjustments 0 Total 21760 100.0 Coolin• Component Btu h/ft2 Btuh %of load Walls 1.4 911 5.1 Glazing 46.3 11102 62.4 Doors 0 0 0 Ceilings 1.7 1983 11.1 Floors 0 0 0 Infiltration 0.8 735 4.1 Ducts 3069 17.2 -- Ventilation 0 0 Internal gains 0 0 Blower 0 0 Adjustments 0 Total 17799 100.0 Latent Cooling Load =2383 Btuh Overall U-value=0.162 Btuh/ft2-°F Data entries checked. wrightsoft Right-Suilecb Universal 2013 13.0.09 RSU13554 2015-Apr-28 12:00.03 ACC* 9 ...s\VJrightsoft HVAC\HABIJAX-TRIPLEX-UNIT-C-MJ.rup Calc=MJ8 Building Front faces. W ro ect Summary Job: HABIJAX-TRIPLEX-UNIT-... P +1+- wrightsoft ry Date: 02/2015 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAEQENGINEER.COM Web:WNNV.NORTHFLORIDAAIR.COM ■ Pro'ect Information For: HABIJAX-TRIPLEX-UNIT-C-MJ, BEACHES HABITAT 138 SANDY BEACH LN, ATLANTIC BEACH, FL 32233 Notes: Desi•n Information Weather: Jacksonville Mayport Naval, FL, US Winter Design Conditions Summer Design Conditions Outside db 39 °F Outside db 92 °F Inside db 70 °F Inside db 75 °F Design TD 31 °F Design TD 17 °F Daily range L Relative humidity 50 % Moisture difference 58 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 19175 Btuh Structure 14731 Btuh Ducts 2585 Btuh Ducts 3069 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 21760 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 17799 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 1 (Average) Structure 1555 Btuh Ducts 828 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft') 1140 1140 Equipment latent load 2383 Btuh Volume (ft') 10260 10260 Air changes/hour 0.57 0.23 Equipment total load 20182 Btuh Equiv.AVF (cfm) 97 39 Req.total capacity at 0.78 SHR 1.9 ton Heating Equipment Summary Cooling Equipment Summary Make CARRIER Make CARRIER Trade 2.0 TON Trade 2.0 TON Model 25HBC524 Cond 25HBC524 AHRI ref 3645571 Coil FX4DNF025 AHRI ref 3645571 Efficiency 8.7 HSPF Efficiency 15.25 SEER Heating input Sensible cooling 18720 Btuh Heating output 24000 Btuh @ 47°F Latent cooling 5280 Btuh Temperature rise 27 °F Total cooling 24000 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.88 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -f+F- wri htsoft 2015-Apr-2812:00.04 9 Right-SuiteE'Universal 2013 13.0.09 RSU13554 Page 1 ACL1". ...s\Wrightson HVAC\HABIJAX-TRIPLEX-UNIT-C-MJ.rup Calc=MJ8 Building Front faces: W 9 AED Assessment Job: HABIJAX-TRIPLEX-UNIT-... +if wrightsoft Date: 02/2015 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAECENGINEER.COM Web:WVWJ.NORTHFLORIDAAIR.COM Project Information For: HABIJAX-TRIPLEX-UNIT-C-MJ, BEACHES HABITAT 138 SANDY BEACH LN,ATLANTIC BEACH, FL 32233 Design Conditions Location: Indoor: Heating Cooling Jacksonville Mayport Naval, FL, US Indoor temperature (°F) 70 75 Elevation: 16 ft Design TD (°F) 31 17 Latitude: 30°N Relative humidity(%) 40 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 15.7 58.2 Dry bulb(°F) 39 92 Infiltration: Daily range (°F) - 15 ( L ) Wet bulb(°F) - 78 Wind speed(mph) 15.0 7.5 Test for Adequate Exposure Diversity FtirtyGLcacl 14,000 12,eer 10,ree 8,eee 6,eer 4,eee 2,eer 0 - I - f I I __ I I I- - 1 f { I 8 9 10 11 12 13 14 15 16 17 18 19 20 Ft“-of Cray Maximum hourly glazing load exceeds average by 16.4%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh 2015-Apr-28 12:00:04 wrightsoft Right-Suite®Universal 2013 13.0.09 RSU13554 Page 1 A ...s\Wrightsoft HVAC\HABIJAX-TRIPLEX-UNIT-C-MJ.rup Calc=MJ8 Building Front faces: W Component Constructions Job: HABIJAX-TRIPLEX-UNIT-... +I+ wrightsoft Date: 0212015 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAE©ENGINEER.COM Web:WWW.NORTHFLORIDAAIR.COM Pro'ect Information For: HABIJAX-TRIPLEX-UNIT-C-MD, BEACHES HABITAT 138 SANDY BEACH LN,ATLANTIC BEACH, FL 32233 Design Conditions Location: Indoor: Heating Cooling Jacksonville Mayport Naval, FL, US Indoor temperature (°F) 70 75 Elevation: 16 ft Design TD (°F) 31 17 Latitude: 30°N Relative humidity(%) 40 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 15.7 58.2 Dry bulb(°F) 39 92 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified \A t bulb(°F) - 78 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain C Bth/R'-'F K-'FIBldi Blh/R' Btuh MEOW Btuh Walls 12B-2bw:Frm wall,brk 4"ext,r-11 cav ins,2"x4"wood frm,r-2 int bd n 631 0.086 13.0 2.67 1682 1.41 887 ins e 46 0.086 13.0 2.67 123 1.41 65 all 677 0.086 13.0 2.67 1805 1.41 952 Partitions (none) Windows 10A-m:1 glazing,reflective(1/4"only)glz,mtl no brk frm mat, 1/4"thk, n 77 1.670 0 51.8 3986 27.6 2123 high rflct pert;8 ft overhang(8 ft window ht,6 ft sep.) 1A-c1om: 1 glazing,clr glz,mtl no brk frm mat, 1/8"thk: 1 ft overhang (6 e 34 1.270 0 39.4 1339 93.5 3180 ft window ht,2 ft sep.) Doors (none) Ceilings 16B-30ad:Attic ceiling,asphalt shingles roof mat,r-31 roof ins,r-30 ceil n 1140 0.032 30.0 0.99 1131 1.74 1983 ins Floors 22A-vph:Bg floor,heavy damp soil,on grade depth,vinyl fir fish n 34 1.358 0 42.1 1431 0 0 .� wrightsoft 2015-Apr-28 11:56:53 1 �� g Right-Suitebu Universal 2013 13.0.09 RSU13554 Page 1 ...s\wrightsoft HVAC\HABIJAX-TRIPLEX-UNIT-C-MD.rup Calc=MJ8 Building Front faces: W nstr om t Constructions Job: HABIJAX-TRIPLEX-UNIT-... + wrightsoft C onen Date: 02/2015 BATH2 By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone.904-823-9696 Email:FAE©ENGINEER.COM Web:WVWV.NORTHFLORIDAAIR.COM Pro'ect Information For: HABIJAX-TRIPLEX-UNIT-C-MD, BEACHES HABITAT 138 SANDY BEACH LN,ATLANTIC BEACH, FL 32233 Design Conditions Location: Indoor: Heating Cooling Jacksonville Mayport Naval, FL, US Indoor temperature (°F) 70 75 Elevation: 16 ft Design TD (°F) 31 17 Latitude: 30°N Relative humidity (%) 40 50 Outdoor: Heating Cooling Moisture difference(grub) 15.7 58.2 Dry bulb(°F) 39 92 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified At bulb(°F) - 78 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain re Btuh/ft'-'F 8' FIBhh BM/R' Btuh Btuh/ft' Btuh Walls 12B-2bw: Frm wall,brk 4"ext,r-11 cav ins,2"x4"wood frm,r-2 int bd n 2 0.086 13.0 2.67 5 1.41 3 ins Partitions (none) Windows 10A-m:1 glazing,reflective(1/4"only)glz,mtl no brk frm mat, 1/4"thk, n 4 1.670 0 51.8 207 27.6 110 high rflct pert;8 ft overhang(8 ft window ht,6 ft sep.) Doors (none) Ceilings 16B-30ad:Attic ceiling,asphalt shingles roof mat,r-31 roof ins,r-30 ceil n 72 0.032 30.0 0.99 71 1.74 125 ins Floors 22A-vph:Bg floor,heavy damp soil,on grade depth,vinyl flr fnsh n 6 1.358 0 42.1 253 0 0 +{+ wri htsott 15-Apr-2811:56:53 ,,,4_- 9 Right-Suite®iht-Suite�iUniv Universal RSU13554 page2 ACC: , ...s\Wrightson HVAC\HABIJAX-TRIPLEX-UNIT-C-MD.rup Calc=MJ8 Building Front faces. W Component Constructions Job: HABIJAX-TRIPLEX-UNIT-... wrightsoft p Date: 02/2015 MBED By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAECENGINEER.COM Web:VWNN.NORTHFLORIDAAIR.COM Pro'ect Information For: HABIJAX-TRIPLEX-UNIT-C-MD, BEACHES HABITAT 138 SANDY BEACH LN,ATLANTIC BEACH, FL 32233 Design Conditions Location: Indoor: Heating Cooling Jacksonville Mayport Naval, FL, US Indoor temperature (°F) 70 75 Elevation: 16 ft Design TD (°F) 31 17 Latitude: 30°N Relative humidity(%) 40 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 15.7 58.2 Dry bulb(°F) 39 92 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Wet bulb(°F) - 78 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' eat,ff'-"F R'-"F/8hh Btuh/114 Btuh Bnh/ft' Btuh Walls 12B-2bw:Frm wall,brk 4"ext,r-11 cav ins,2"x4"wood frm,r-2 int bd n 111 0.086 13.0 2.67 296 1.41 156 ins Partitions (none) Windows 10A-m: 1 glazing,reflective(1/4"only)glz,mtl no brk frm mat, 1/4"thk, n 31 1.670 0 51.8 1605 27.6 855 high rflct pert;8 ft overhang(8 ft window ht,6 ft sep.) Doors (none) Ceilings 16B-30ad:Attic ceiling,asphatt shingles roof mat,r-31 roof ins,r-30 ceil n 181 0.032 30.0 0.99 180 1.74 315 ins Floors (none) +1+ wri htsoft 2015-Apr-28 11:56:53 9 Right-Su Page 3 ...s\wrightsoft HVAC\HABIJAX-TRIPLEX-UNIT-C-MD.rup Caic=MJ8 Building Front faces. W Component Constructions Job: HABIJAX-TRIPLEX-UNIT-... 4 wrightsoft Date: 02/2015 BED2 By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAE @ENGINEER.COM Web:WWW.NORTHFLORIDAAIR.COM Pro'ect Information For: HABIJAX-TRIPLEX-UNIT-C-MD, BEACHES HABITAT 138 SANDY BEACH LN,ATLANTIC BEACH, FL 32233 Design Conditions Location: Indoor: Heating Cooling Jacksonville Mayport Naval, FL, US Indoor temperature (°F) 70 75 Elevation: 16 ft Design TD (°F) 31 17 Latitude: 30°N Relative humidity(%) 40 50 Outdoor: Heating Cooling Moisture difference (gr/Ib) 15.7 58.2 Dry bulb(°F) 39 92 Infiltration: Dailyrange (°F) - 15 ( L ) Method Simplified V■kt bulb(°F) - 78 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain If Btuh/.-"F fN-'Fah Bhh/fe Btuh Btuh/ft Btuh Walls 12B-2bw: Frm wall,brk 4"ext,r-11 cav ins,2"x4"wood frm,r-2 int bd n 128 0.086 13.0 2.67 341 1.41 180 ins Partitions (none) Windows 10A-m: 1 glazing,reflective(1/4"only)glz,mtl no brk frm mat, 1/4"thk. n 14 1.670 0 51.8 725 27.6 386 high rflct pert:8 ft overhang(8 ft window ht.6 ft sep.) Doors (none) Ceilings 16B-30ad:Attic ceiling,asphalt shingles roof mat,r-31 roof ins,r-30 ceil n 171 0.032 30.0 0.99 170 1.74 297 ins Floors (none) 2015-Apr-28 11:56:53 wrightsoft Right-Suitee Universal 2013 13.0.09 RSU13554 Page4 ...s\Wrightsoft HVAC\HABIJAX-TRIPLEX-UNIT-C-MD.rup Caic=MJ8 Building Front faces: W Component Constructions Job: HABIJAX-TRIPLEX-UNIT-... om 4 wrightsoft P Date: 02/2015 GREAT By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAEiENGINEER.COM Web:WVVW.NORTHFLORIDAAIR.COM i Pro'ect Information For: HABIJAX-TRIPLEX-UNIT-C-MD, BEACHES HABITAT 138 SANDY BEACH LN,ATLANTIC BEACH, FL 32233 Design Conditions Location: Indoor: Heating Cooling Jacksonville Mayport Naval, FL,US Indoor temperature(°F) 70 75 Elevation: 16 ft Design TD(°F) 31 17 Latitude: 30°N Relative humidity(%) 40 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 15.7 58.2 Dry bulb(°F) 39 92 Infiltration: Daily range(°F) - 15 ( L ) Method Simplified ' At bulb(°F) - 78 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' BuUM-'F ft'-'Ft9hh Bohm' Btuh BtuhW Btuh Walls 12B-2bw:Frm wall,brk 4"ext,r-11 cav ins,2"x4"wood frm,r-2 int bd n 111 0.086 13.0 2.67 296 1.41 156 ins e 46 0.086 13.0 2.67 123 1.41 65 all 157 0.086 13.0 2.67 419 1.41 221 Partitions (none) Windows 1A-c1 om:1 glazing,dr glz,mU no brk frm mat,1/8"thk;1 ft overhang(6 e 34 1.270 0 39.4 1339 93.5 3180 ft window ht,2 ft sep.) Doors (none) Ceilings 16B-30ad:Attic ceiling,asphalt shingles roof mat,r-31 roof ins,r-30 ceil n 255 0.032 30.0 0.99 253 1.74 443 ins Floors 22A-vph:Bg floor,heavy damp soil,on grade depth,vinyl flr fish n 12 1.358 0 42.1 505 0 0 2015-Apr-28 11:56:53 wrightsoft. Right-Suite®Universal 2013 13.0.09 RSU13554 page 5 ...s\Wrightsoft HVAC\HABIJA(-TRIPLEX-UNIT-C-MD.rup Cak=MJ8 Building Front faces: W Component Constructions Job: HABIJAX-TRIPLEX-UNIT-... - + wrightsoft Date: 0212015 MVVIC By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone:904823-9696 Email:FAE©ENGINEER.COM Web:WWW.NORTHFLORIDAAIR.COM Pro'ect Information For: HABIJAX-TRIPLEX-UNIT-C-MD, BEACHES HABITAT 138 SANDY BEACH LN,ATLANTIC BEACH, FL 32233 Design Conditions Location: Indoor: Heating Cooling Jacksonville Mayport Naval, FL, US Indoor temperature (°F) 70 75 Elevation: 16 ft Design TD (°F) 31 17 Latitude: 30°N Relative humidity (%) 40 50 Outdoor: Heating Cooling Moisture difference(grub) 15.7 58.2 Dry bulb(°F) 39 92 Infiltration: Dailyrange (°F) - 15 ( L ) Method Simplified VVet bulb(°F) - 78 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain tt' Buhrir-'F R'-'F/Btuh B5i m' Btuh Btuh/ft' Btuh Walls 12B-2bw:Frm wall,brk 4"ext,r-11 cav ins,2"x4"wood frm.r-2 int bd n 9 0.086 13.0 2.67 24 1.41 13 ins Partitions (none) Windows (none) Doors (none) Ceilings 16B-30ad:Attic ceiling,asphalt shingles roof mat,r-31 roof ins,r-30 cell n 32 0.032 30.0 0.99 32 1.74 56 ins Floors 22A-vph:Bg floor,heavy damp soil,on grade depth,vinyl flr fish n 8 1.358 0 42.1 337 0 0 41 wrightsoft 2015-Apr-28 11:56:53 a 9 Right-Suitevu Universa1201313.0.09 RSU13554 Page6 ...s\Wrightsoft HVAC\HABIJAX-TRIPLEX-UNIT-C-MD.rup Calc=MJ8 Building Fronl faces: W Component Constructions Job: HABIJAX-TRIPLEX-UNIT-... ++ wrightsoft Date: 0212015 BATHI By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAE @ENGINEER.COM Web:WWW.NORTHFLORIDAAIR.COM Pro'ect Information For: HABIJAX-TRIPLEX-UNIT-C-MD, BEACHES HABITAT 138 SANDY BEACH LN,ATLANTIC BEACH, FL 32233 Design Conditions Location: Indoor: Heating Cooling Jacksonville Mayport Naval, FL, US Indoor temperature (°F) 70 75 Elevation: 16 ft Design TD (°F) 31 17 Latitude: 30°N Relative humidity(%) 40 50 Outdoor: Heating Cooling Moisture difference(grab) 15.7 58.2 Dry bulb(°F) 39 92 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified Vet bulb(°F) - 78 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' Btuh tIV--F ft'-'F/Bhh Bbth/M Btuh BtuhKt' Btuh Walls 12B-2bw:Frm wall,brk 4"ext,r-11 cav ins,2"x4"wood frm,r-2 int bd n 6 0.086 13.0 2.67 16 1.41 8 ins Partitions (none) Windows (none) Doors (none) Ceilings 16B-30ad:Attic ceiling,asphalt shingles roof mat,r-31 roof ins,r-30 cell n 52 0.032 30.0 0.99 52 1.74 90 ins Floors (none) 1 p wrightsoft htsoft 2015-Apr-28 11:56:53 7 �� g Rig Pagel ...s\Wnghtsott HVAC\HABIJAX-TRIPLEX-UNIT-C-MD.rup Calc=MJ8 Building Front faces: W 4 wrightsoft Component Constructions Job: HABIJAX-TRIPLEX-UNIT-...Date: 0212015 MECH By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAECIENGINEER.COM Web:VWWV.NORTHFLORIDAAIR.COM 1 Pro-ect Information For: HABIJAX-TRIPLEX-UNIT-C-MD, BEACHES HABITAT 138 SANDY BEACH LN,ATLANTIC BEACH, FL 32233 Design Conditions Location: Indoor: Heating Cooling Jacksonville Mayport Naval, FL,US Indoor temperature(°F) 70 75 Elevation: 16 ft Design TD(°F) 31 17 Latitude: 30°N Relative humidity(%) 40 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 15.7 58.2 Dry bulb(°F) 39 92 Infiltration: Daily range(°F) - 15 ( L ) Method Simplified Wet bulb(°F) - 78 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain II' Bhh/ft-°F R.°F/Btuh BthAN Btuh Btuh/R' Btuh Walls 12B-2bw:Frm wall,brk 4"ext,r-11 cav ins,2"x4"wood frm,r-2 int bd n 8 0.086 13.0 2.67 21 1.41 11 ins Partitions (none) Windows (none) Doors (none) Ceilings 16B-30ad:Attic ceiling,asphalt shingles roof mat,r-31 roof ins,r-30 cell n 48 0.032 30.0 0.99 48 1.74 83 ins Floors 22A-vph:Bg floor,heavy damp soil,on grade depth,vinyl fir fnsh n 8 1.358 0 42.1 337 0 0 2015-Apr-28 11:56:53 Awrightsoft Rig Universal 2013 Page8 ...s\wrightsoft HVAC\HABIJAX-TRIPLEX-UNIT-C-MD.rup Ca c=MJ8 Building Front faces: W Component Com Constructions Job: HABIJAX-TRIPLEX-UNIT-... 4" wrightsoft p Date: 02/2015 BED3 By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAEgENGINEER.COM Web:WWW.NORTHFLORIDAAIR.COM Pro'ect Information For: HABIJAX-TRIPLEX-UNIT-C-MD, BEACHES HABITAT 138 SANDY BEACH LN,ATLANTIC BEACH, FL 32233 Design Conditions Location: Indoor: Heating Cooling Jacksonville Mayport Naval,FL,US Indoor temperature(°F) 70 75 Elevation: 16 ft Design TD(°F) 31 17 Latitude: 30°N Relative humidity(%) 40 50 Outdoor: Heating Cooling Moisture difference(gr./lb) 15.7 58.2 Dry bulb(°F) 39 92 Infiltration: Daily range (°F) - 15 ( L ) Method Simplified VAt?t bulb(°F) - 78 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' Bohm'-`F K-'FIBhh BGhM' Btuh BtuhRt2 Ruh Walls 12B-2bw:Frm wall,brk 4"ext,r-11 cav ins,2"x4"wood frm,r-2 int bd n 128 0.086 13.0 2.67 341 1.41 180 ins Partitions (none) Windows 10A-m:1 glazing,reflective(1/4"only)glz,mU no brk frm mat, 1/4"thk, n 14 1.670 0 51.8 725 27.6 386 high rftct pert;8 ft overhang(8 ft window ht,6 ft sep.) Doors (none) Ceilings 16B-30ad:Attic ceiling,asphalt shingles roof mat,r-31 roof ins,r-30 ceil n 151 0.032 30.0 0.99 150 1.74 263 ins Floors (none) W ti�htsOtFt 2015-Apr-2811:56:53 `.i Right-Suite®Universal 2013 RSU13554 Page9 ...s\Wrightsoft HVACWABIJAX-TRIPLEX-UNIT-C-MD.rup Calc=MJ8 Building Front faces: W om onent Constructions Job: HABIJAX-TRIPLEX-UNIT-... C 4 wrightsoft p Date: 02/2015 KITCHEN By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAE6ENGINEER.COM Web:WVWV.NORTHFLORIDAAIR.COM Pro'ect Information For: HABIJAX-TRIPLEX-UNIT-C-MD, BEACHES HABITAT 138 SANDY BEACH LN,ATLANTIC BEACH, FL 32233 Design Conditions Location: Indoor: Heating Cooling Jacksonville Mayport Naval, FL,US Indoor temperature(°F) 70 75 Elevation: 16 ft Design TD(°F) 31 17 Latitude: 30°N Relative humidity(%) 40 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 15.7 58.2 Dry bulb(°F) 39 92 Infiltration: Daily range(°F) - 15 ( L ) Method Simplified Mt bulb(°F) - 78 Construction quality Average Wind speed(mph) 15.0 7.5 Fireplaces 1 (Average) Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain R Bhh/R'-'F R'-'F/Bhh a i-,m' Btuh Bhhft' Btu, Walls 12B-2bw:Frm wall,brk 4"ext,r-11 cav ins,2"x4"wood frm,r-2 int bd n 128 0.086 13.0 2.67 341 1.41 180 ins Partitions (none) Windows 10A-m:1 glazing,reflective(1/4"only)glz,mtl no brk frm mat,1/4"thk, n 14 1.670 0 51.8 725 27.6 386 high rflct pert:8 ft overhang(8 ft window ht,6 ft sep.) Doors (none) Ceilings 16B-30ad:Attic ceiling,asphalt shingles roof mat,r-31 roof ins,r-30 ceil n 178 0.032 30.0 0.99 177 1.74 310 ins Floors (none) 1 -+ wrightsoft Right-Suite®Universal 2013 13.0.09 RSU13554 2015-Apr-28 11:ge:50 Page 10 ...s\Wrightsoft HVAC\HABIJAX-TRIPLEX-UNIT-C-MD.rup Calc=MJ8 Building Front faces: W Duct System Summary Job: HABIJAX-TRIPLEX-UNIT-... --44- D wrightsoft y ry Date: 0212015 Entire House By: JLF FLORIDA AIR SERVICE & ENGINEERING 150 HILDEN RD 308,PONTE VEDRE,FL 32081 Phone:904-823-9696 Email:FAEtENGINEER.COM Web:WVWV.NORTHFLORIDAAIR.COM Project Information For: HABIJAX-TRIPLEX-UNIT-C-MD, BEACHES HABITAT 138 SANDY BEACH LN,ATLANTIC BEACH, FL 32233 Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.250/0.250 in H2O 0.250/0.250 in H2O Lowest friction rate 0.500 in/100ft 0.500 in/100ft Actual air flow 800 cfm 800 cfm Total effective length (TEL) 377 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk MECH h 544 28 10 0.500 4.0 Ox 0 VIFx 307.0 70.0 BATH2 h 696 36 25 0.500 4.0 Ox 0 VIFx 307.0 70.0 MBED h 3317 173 148 0.500 7.0 Ox 0 VIFx 307.0 70.0 BEDS h 2245 117 97 0.500 6.0 Ox 0 VIFx 307.0 70.0 KITCHEN h 2278 119 102 0.500 6.0 Ox 0 VIFx 307.0 70.0 8E02 h 2270 119 101 0.500 6.0 Ox 0 VIFx 307.0 70.0 GREAT c 2103 87 149 0.500 6.0 Ox 0 VIFx 307.0 70.0 GREAT-A c 2103 87 149 0.500 6.0 Ox 0 VIFx 307.0 70.0 BATH1 c 149 6 11 0.500 4.0 Ox 0 VIFx 307.0 70.0 M\Mc h 533 28 8 0.500 4.0 Ox 0 VIFx 307.0 70.0 wrl htsoft 2015-Apr-28 11:56.25 Zt` g Right-SuiteN�Universal 2013 13.0.09 RSU13554 Page 1 e 1 Ck ...s\Wrightsoft HVAC\HABIJAX-TRIPLEX-UNIT-C-MD.rup Calc=MJ8 Building Front faces: W .u:milli CERTIFIED' www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 3645571 Date: 4/27/2015 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 25HBC524A**30 Indoor Unit Model Number: FX4DNF025 Manufacturer: CARRIER AIR CONDITIONING Trade/Brand name: CARRIER Series name: COMFORT 13 PURON HP Manufacturer responsible for the rating of this system combination is CARRIER AIR CONDITIONING Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity (Btuh): 24000 EER Rating (Cooling): 12.00* SEER Rating (Cooling): 15.25 Heating Capacity(Btuh) @ 47 F: 24000 Region IV HSPF Rating (Heating): 8.70 Heating Capacity(Btuh) @ 17 F: 14700 'Ratings followed by an asterisk(•)indicate a voluntary rerate of previously published data.unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahrldlrectory.org. TERMS AND CONDITIONS AI um, This Certificate and Its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated; .. �' entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's Individual. personal and confidential reference. AIR-CONDITIONING.HEATING, CERTIFICATE VERIFICATION &REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahridlrectory.org,click on"Verify Certificate"link me make We better"' and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above,and the Certificate No.,which Is listed at bottom right. 1 307461 3161 91 09909 ©2014 Air-Conditioning, Heating,and Refrigeration Institute ( CERTIFICATE NO.: