Loading...
1705 MARITIME OAK DR - ENERGY McGowan's Manual S Compliance Report Job:Date: "eacngBAir (Rest of House) FILE topy Conditioning, '' �. I McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Ft 32073 Phone:904-278-0339 Fax:904-278-0366 Email:jjacobs @mcgowansac.com Web:www.mcgowansac.com Project Information For: Toll Brothers Fl Cooling Equipment Design Conditions Outdoor design DB: 99.2°F Sensible gain: 27258 Btuh Entering coil DB: 75.8°F Outdoor design WB: 80.2°F Latent gain: 4361 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 31619 Btuh Indoor RH: 50% Estimated airflow: 1100 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0360000A+FB4CNP036L Actual airflow: 1100 cfm Sensible capacity: 28403 Btuh 104%of load Latent capacity: 4361 Btuh 100%of load Total capacity: 32764 Btuh 104%of load SHR: 87% Heating Equipment Design Conditions Outdoor design DB: 31.7°F Heat loss: 30630 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0360000A+FB4CNP036L Actual airflow: 1100 cfm Output capacity: 33000 Btuh 108%of load Capacity balance: 30 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1100 cfm Output capacity: 9.7 kW 108%of load Temp. rise: 50 °F The above equipment was selected in accordance with ACCA Manual S. 2015-Jul-01 08:54:19 �, wf ughtsoft- Comfort Builder by Wrighlsoft 15.0.17 RSU12270 Page 1 / +M ...300 RES NC\Toll Brothers\Lot 93 AB Manual S.rup Calc=MJ8 House faces:SW 1V Manual S Compliance Report Job: cGowan .�) P p Date: Heating&Air t i up By. Conditioning tK•saw�tK•v.• I.. VVVAAA McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:jjacobs©mcgowansac.com Web:www.mcgowansac.com Project Information For: Toll Brothers Fl Cooling Equipment Design Conditions Outdoor design DB: 99.2°F Sensible gain: 14930 Btuh Entering coil DB: 75.9°F Outdoor design WB: 80.2°F Latent gain: 1722 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 16652 Btuh Indoor RH: 50% Estimated airflow: 593 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0180000A+FB4CNP018L Actual airflow: 593 cfm Sensible capacity: 14930 Btuh 100%of load Latent capacity: 1722 Btuh 100%of load Total capacity: 16652 Btuh 100%of load SHR: 90% Heating Equipment Design Conditions Outdoor design DB: 31.7°F Heat loss: 11409 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB0180000A+FB4CNP018L Actual airflow: 593 cfm 156% Capacity balance: 22 °F Output capacity: 17800 Btuh 156/0 of load p y Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 593 cfm Output capacity: 3.3 kW 98%of load Temp. rise: 17 °F The above equipment was selected in accordance with ACCA Manual S. 2015-Jul-01 08:54:19 wrightsoft' Comfort Builder by Wrightsoft 15.0.17 RSU12270 Page 2 AFOk ...300 RES NC1Toll Brothers\Lot 93 AB Manual S.rup Calc=MJ8 House faces:SW I k FILE COPY FORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Anastasia Bonus 3621 Left Builder Name: Toll Brothers,Inc. Street: 1705 Maritime Oak Dr Permit Office: Atlantic Beach r' ivy-y City,State,Zip: Atlantic Beach,FL, - Permit Number: /S-.�I'-f Owner: Toll Brothers,Inc. Jurisdiction: 261300 Design Location: FL,Jacksonville 1. New construction or existing New(From Plans) 9. Wall Types(2915.3 sqft.) Insulation Area a.Frame-Wood,Exterior R=19.0 2663.30 ft2 i 2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=13.0 252.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types (2991.0 sqft.) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=38.0 2866.00 ft2 6. Conditioned floor area above grade(ft2) 3621 b.Knee Wall(Vented)• R=19.0 125.00 ft2 c.N/A R= ft2 Conditioned floor area below grade(ft2) 0 11.Ducts R ft2 7. Windows(413.6 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Attic 6 253 a. U-Factor: Dbl,U=0.34 413.56 ft2 b.Sup: Attic,Ret:Attic,AH:Attic 6 200 SHGC: SHGC=0.27 12.Cooling systems kBtu/hr Efficiency b. U-Factor: N/A ft2 a.Central Unit 18.0 SEER:14.00 SHGC: b.Central Unit 36.0 SEER:14.00 c. U-Factor: N/A ft2 ■ SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 18.0 HSPF:8.00 SHGC: b.Electric Heat Pump 36.0 HSPF:8.00 Area Weighted Average Overhang Depth: 6.727 ft. 14.Hot water systems Area Weighted Average SHGC: 0.270 Cap: 1 gallons a.Natural Gas Tankless P� 9 8. Floor Types (3621.0 sqft.) Insulation Area EF:0.900 a.Slab-On-Grade Edge Insulation R=0.0 2696.00 ft2 b. Conservation features • b.Floor Over Other Space R=0.0 755.00 ft2 None , c.other(see details) R= 170.00 ft2 15.Credits Pstat Total Proposed Modified Loads: 35.21 PASS Glass/Floor Area: 0.114 Total Standard Reference Loads: 66.29 - I hereby certify that the plans and specifications covered by Review of the plans and .,••'�4ZKE,$TgTd:° this calculation are in compliance with the Florida Energy specifications covered by this :`Q A.-;-. �=s c Code calculation indicates compliance =s4..,.���..' .p� r,,,�•• with the Florida Energy Code. 'E•=rrr�n " - ,-1 .'• PREPARED Y: =-,-� - 7 I I Before construction is completed 1 g, y this building will be Inspected for z DATE: � ��� _ " compliance with Section 553.906 *` 4 Florida Statutes. .ir' I hereby certify that this building,as designed,is in compliance `••.COD WB 0'` with the Florida Energy Code. ••• C. / BUILDING OFFICIAL: ) OWNER/AGENT: ✓� 6'��q- i S DATE: =UM DATE: - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist 4/8/2015 8:55 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6 P • PROJECT Title: Anastasia Bonus 3621 Left Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 3621 - Lot# Owner: Toll Brothers,Inc. Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Toll Brothers,Inc. Rotate Angle: 0 .Street: 1705 Maritime Oak Dr . Permit Office: Atlantic Beach Cross Ventilation: No • County: Duval Jurisdiction: 261300 Whole House Fan: No City,State,Zip: Atlantic Beach, Family Type: Single-family FL, - New/Existing: New(From Plans) . Comment: • ` CLIMATE / Design Location TMY Site IECC Design Temp Int Design Temp Heating Design Daily Temp Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range V FL,Jacksonville FL_JACKSONVILLE_INT 2 32 93 70 75 1281 49 Medium BLOCKS Number Name Area Volume . 1 Blockl 2696 26960 2 Block2 925 8325 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 2696 26960 Yes 4 3 1 Yes Yes Yes 2 2nd Floor 925 8325 No 1 1 1 Yes Yes Yes FLOORS V # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet I ___1Z 1 Slab-On-Grade Edge Insulatio Main 268 ft 0 2696 ft2 0 0 1 I t// 2 Floor Over Other Space 2nd Floor —_ ____ 755 ft2 0 0 0 1 f 3 Floor over Garage 2nd Floor ___ ---- 170 ft2 19 0 0 1 •I • ROOF • I ` / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch I V # Type Materials Area Area Color Absor. Tested Tested Instil.' •(deg) I 1 Gable or shed Composition shingles 3319 ft2 838 ft2 Medium 0.6 N • 0.9 No 0 30.3 i ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC I 1 1 Full attic Vented 300 2866 ft2 N N I i I I 1 i 4/8/2015 8:55 AM EnergyGauge'�9 USA-FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6 i CEILING � / # Ceiling Type Space R-Value Area Framing Frac Truss Type V ` 1 Knee Wall(Vented) Main 19 125 ft2 0.11 Wood 2 Under Attic(Vented) 2nd Floor 38 925 ft2 0.11 Wood 3 Under Attic(Vented) Main 38 1941 ft' 0.11 Wood • WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below If Ornt To Wall Type S p R-Value Ft Ir Ft_ In Area • R-Value Fraction. Absor Grede% 1 NW Exterior Frame-Wood 2nd Floor 19 33 6 9 0 301.5 ft2 0 0.23 • 0.8 0 _ 2 NW Exterior Frame-Wood Main 19 58 8 10 0 586.7 ft2 0 0.23 0.8 0 3 SW Exterior Frame-Wood 2nd Floor 19 19 0.. 9 0. . 171.0 ft' 0 . 0.23 0.8 0 4 SW Exterior Frame-Wood Main 19 18 2 10 0 181.7 ft2 0 0.23 0.8 0 5 SE Exterior . Frame-Wood 2nd Floor 19 3 6 9 0 31.5 ft2 0: 0.23 0.8 0 6 SE Exterior Frame-Wood Main 19 82 0 10 0 820.0 ft' 0 0.23 0.8 0 7 NE Exterior Frame-Wood 2nd Floor 19 19 0 9 0 171.0 ft' .0 0.23 0.8 0 8 NE Exterior Frame-Wood Main 19 40 0 10 0 400.0 ft2 0 0.23 0.8 0 9 SW Garage Frame-Wood Main 13 28 0 9 0 252.0 ft2 0 0.23 0.8 0 j DOORS V # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SW Insulated Maln None .54 3 8 24 ft2 2 SW Insulated Main None .39 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. / Wall Overhang �/ /# Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening _ 1 NW 2 Vinyl Low-E Double Yes 0.34 0.27 60.0 ft' 1 ft 4 in 11 ft 6 in None Exterior 5 2 NW 1 Vinyl Low-E Double Yes 0.34 0.27 75.0 ft2 1 ft 4 in 1 ft 6 in None Exterior 5 3 SW 3 Vinyl Low-E Double Yes 0.34 0.27 15.0 ft' 1 ft 4 in 1 ft 6 in None Exterior 5 4 SW 4 Vinyl Low-E Double Yes 0.34 0.27 38.0 ft' 3 ft 4 in 1 ft 6 in None Exterior 5 • 5 SE 6 Vinyl Low-E Double Yes 0.34 0.27 45.0 ft' 1 ft 4 in 1 ft 6 in None Exterior 5 6 NE 8 Vinyl Low-E Double Yes 0.34 0.27 128.0 ft? 18 ft 2 In 1 ft 6 in None Exterior 5 7 NE 8 Vinyl Low-E Double Yes 0.34 0.27 30.0 ft' 1 ft 4 in 1 ft 6 in None Exterior 5 8 NE 8 Vinyl Low-E Double Yes 0.34 0.27 3.6 ft' 1 ft 4 in 1 ft 6 in None Exterior 5 i 9 SE 6 Vinyl Low-E Double Yes 0.34 0.27 19.0 ft' 1 ft 4 in 1 ft 6 in None Exterior 5 GARAGE • # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 602 ft' 432 ft2 64 ft 9.ft 1 . 4/8/2015 8:55 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6 1 INFILTRATION # Scope Method SLA CFM 50 ELA EcLA ACH ACH 50 1 Wholehouse Best Guess .0003 2849.4 156.43 294.18 • .2844 • 4.8452 HEATING,SYSTEM.. . • . • V # System Type Subtype • Efficiency Capacity Block Ducts •• 1/f 1 Electric Heat Pump None • HSPF:8 18 kBtu/hr •.2 sys#2 • V •2 Electric Heat Pump None HSPF:8 36 kBtu/hr .1 sys#1 COOLING SYSTEM V # System Type Subtype Efficiency Capacity Air Flow . SHR Block Ducts (/ 1 Central Unit Split SEER:14 18 kBtu/hr 540 cfm 0.699999 . 2 sys#2 2 Central Unit Split SEER:14 36 kBtu/hr 1080 cfm 0.7 1 sys#1 • HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Natural Gas Tankless Exterior 0.9 1 gal 60.9.gal 120 deg None SOLAR HOT WATER SYSTEM VFSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / --Supply--- ---Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool V(/ Attic 6 253 ft2 Attic 123 ft2 Default Leakage :Attic (Default) (Default) 2 2 - 2 Attic 6 200 ft2 Attic 85 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES • Programable Thermostat:Y Ceiling Fans: Cooling Jan Feb Mar Apr May X Jun Jul X Au X Se Oct Nov j X Dec Heating f Jan fX�Feb X Mar Apr May Jun Jul Au Sep Venting l Jan 1 1 Feb Xi Mar [XX Apr 1 i May t 1 Jun 1 Jul t 1 Aug t 1 Sep X;Oct . €XX Nov t ;Dec : - 1 4/8/2015 8:55 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6 Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 . 3 4 . 5 . . .6 _ 7. 8 9 10 11 12 Cooling(WD) PM 80 78 78 78 78 78 78 78 80 80 80 78 Cooling(WEH) AM 78 • 78 78 78 78 . • 78 78 78 . 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM. .66 •. 66 66. 66 66 68 68 • 68 68 68- 68 • 68 PM 68 ' '68' 68 68 68 68 68 68 68 68. 66 66 Heating(WEH) AM ' 68 66 • 66 66 .66 • 68 68 68 68 68 668 66 f� • • • • • • • • • 4/8/2015 8:55 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6 1 FORM 405-10 Checklist Florida Code Compliance Florida Department of Business and Professional Regulations Residential Whole Building Performance Method . ADDRESS: 1705 Maritime Oak Dr • PERMIT#: • • Atlantic Beach, FL, - MANDATORY REQUIREMENTS SUMMARY-See individual code sections for full details. COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK . Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC-rated as meeting ASTM E 283. Windows and doors=0.30 cfm/sq.ft.Testing or visual inspection required. Fireplaces: gasketed doors&outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat& 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system.Where forced-air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can _meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 ~ Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric)or shutoff(gas). Circulating system pipes insulated to= R-2 -- ---N--J - -- + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics,crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower(HP) of= 1 &Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor-retardant covers or a liquid cover or \ other means proven to reduce heat loss except if 70% of heat from r site-recovered energy. Off/timer switch required. Gas heaters minimum U —thermal-efficiency=78%(82%after 1/16/13)-Heat pump-pool-heaters minimum COP=4.0. Cooling/heating 403.6 Sizing calculation performed &attached. Minimum efficiencies per . Tables 503.2.3. Equipment efficiency verification required. Special equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat>10kW must be divided into two or more stages. \ Ceilings/knee walls 405.2.1 R-19 space permitting. 4/8/2015 8:55 AM EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 6 • ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD • ESTIMATED ENERGY PERFORMANCE INDEX* = 53 • The lower the EnergyPerformance Index,the more efficient the home. 1705 Maritime Oak Dr, Atlantic Beach, FL, - 1. New construction or existing • New(From Plans) 9. Wall Types Insulation Area a.Frame-Wood,Exterior . R=19.0 2663.30 ft= . 2. Single family or multiple family Single-family b.Frame-Wood,Adjacent R=13.0 252.00 ft= 3. Number of units,if multiple family 1 c.N/A R= ft2 d.N/A R= ft2 4. Number of Bedrooms 4 Insulation Area 10.Ceiling Types 5. Is this a worst case? No a.Under Attic(Vented) R=38.0 2866.00 ft2 6. Conditioned floor area(ft2) 3621 b.Knee Wall(Vented) R=19.0 125.00 ft2 c.N/A R= ft 7. Windows" Description :Area . . 11.Ducts R ft2 a. U-Factor: Dbl,U=0.34 . 413.56 ft2 a.Sup:Attic,Ret:Attic,AH:Attic 6 253 SHGC: SHGC=0.27 b.Sup: Attic,Ret:Attic,AH:Attic 6 200 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency ft2 a.Central Unit 18.0 SEER:14.00 S HGC: c. Factor: N/A b.Central Unit 36.0 SEER:14.00 SHGC: d. U-Factor: N/A ft2 kBtu/hr Efficiency 13.Heating systems y SHGC: a.Electric Heat Pump 18.0 HSPF:8.00 Area Weighted Average Overhang Depth: 6.727 ft. b.Electric Heat Pump 36.0 HSPF:8.00 Area Weighted Average SHGC: 0.270 8. Floor Types Insulation Area 14.Hot water systems Cap:1 gallons a.Slab-On-Grade Edge Insulation R=0.0 2696.00 ft2 a.Natural Gas EF:0.9 b.Floor Over Other Space R=0.0 755.00 ft2 b. Conservation features c.other(see details) R= 170.00 ft2 None ___. 15.Credits - ._. Pstat i P� Vy,, I certify that this home has complied with the Florida Energy Efficiency Code for Building .•,rO4.fIES4l ..,e Construction through the above energy saving features which will be installed (or exceeded) P�, ,�,� •£• o in this home before final inspection. Otherwise, a new EPL Display Card will be completed ;��,w;'4' '4 y� based on installed Code compliant -atures. i--,fo«. _;tr:°:.•°;,:�o` • Date: �//S ,s c� �6 a Builder Signature: / .._ * . t&D'^' City/FL Zip: SZZ3 ,`f � 9 Address of New Home: 1'10s Lx1��tYrie( .-....0D ¢•..- • • *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient . mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) - 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For. .• information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. • EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software TABLE 402.4.2 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Anastasia Bonus 3621 Left Builder Name: Toll Brothers,Inc. Street: 1705 Maritime Oak Dr . Permit Office: Atlantic Beach City,State,Zip: Atlantic Beach,FL, Permit Number: Owner: Toll Brothers,Inc. Jurisdiction: 261300 • Design Location: FL,Jacksonville • COMPONENT CRITERIA CHECK Air barrier and thermal barrier Exterior thermal envelope insulation for framed walls is installed in substantial contact and continuous alignment with building envelope air barrier. il • Breaks or joints in the air barrier are filled or repaired. Air-permeable insulation is not used as a sealing material. Air-permeable insulation is inside of an air barrier. Ceiling/attic Air barrier in any dropped ceiling/soffit is substantially aligned with insulation and any gaps are sealed. Attic access(except unvented attic), knee wall door, or drop down stair is sealed. Walls Corners and headers are insulated. Junction of foundation and sill plate is sealed. Windows and doors Space between window/door jambs and framing is sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including Insulation is installed to maintain permanent contact with underside above-garage and cantilevered of subfloor decking. floors) Air barrier is installed at any exposed edge of insulation. Crawl space walls Insulation is permanently attached to walls. _ Exposed earth in unvented crawl spaces is covered with Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, knee walls and flue shafts opening to exterior or unconditioned space are sealed. Narrow cavities Batts in narrow cavities are cut to fit, or narrow cavities are filled by sprayed/blown insulation. Garage separation Air sealing is provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures are air tight, IC rated, and sealed to drywall. Exception—fixtures in conditioned space. Plumbing and wiring Insulation is placed between outside and pipes. Batt insulation is cut to fit around wiring and plumbing, or sprayed/blown insulation -extends-behind piping and wiring. -- . .-S_.. - Shower/tub on exterior wall Showers and tubs.on exterior walls have insulation and an air barrier . , separating them from the exterior wall. . Electrical/phone box on Air barrier extends behind boxes or air sealed-type boxes are - . .installed. Common wall Air barrier is installed in common wall between dwelling units. HVAC register boots HVAC register boots that penetrate building envelope are sealed to N. subfloor or drywall. N. Fireplace Fireplace walls include an air barrier. EnergyGauge®USA-FlaRes2010 Section 405.4.1 Compliant Software • McGowan Project Summary Job:Date: Heating&A4ir`� (Rest of House) By: Korey Kasch Conditioning ""��■�0,1 McGowan's Heating &Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:korey@mcgowansac.com Web:www.mcgowansac.com Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone:(904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten @tollbrothersinc.com Notes: The Anastasia Desi• n Information Weather: Jacksonville, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 93 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 18 °F Daily range M Relative humidity 50 % Moisture difference 52 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 24963 Btuh Structure 14856 Btuh Ducts 3415 Btuh Ducts 3992 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 28377 Btuh Use manufacturer's data n Rate/swing multiplier 0.98 Infiltration Equipment sensible load 26462 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3329 Btuh Ducts 670 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 2696 2696 Equipment latent load 4755 Btuh Volume(113) 26773 26773 Air changes/hour 0.25 0.13 Equipment total load 31217 Btuh Equiv.AVF(cfm) 112 60 Req.total capacity at 0.70 SHR 3.2 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model CH14NB037 Cond CH14NB037 AHRI ref Coil FB4CNP036 AHRI ref Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 23800 Btuh Heating output 34000 Btuh @ 47°F Latent cooling 10200 Btuh Temperature rise 27 °F Total cooling 34000 Btuh Actual air flow 1133 cfm Actual air flow 1133 cfm Air flow factor 0.040 cfm/Btuh Air flow factor 0.060 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.82 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2015-Apr-0214:49:54 ■_ "�" wrightsoft' Comfort Builder by Wrightsoft 15.0.06 RSU12270 Page 1 ...NC\Toll Brothers\Anastasia Bonus 3621 left.rup Cale=MJ8 Front Door faces:SW • McGowan Project Summary Job: Date: Heating Air P By: Korey Kasch Conditioning U : "-. McGowan's Heating &Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:korey(Dmcgowansac.00m Web:www.mcgowansac.com Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email:smerten @tollbrothersinc.com Notes: The Anastasia Desi• n Information Weather: Jacksonville, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 °F Outside db 93 °F Inside db 70 °F Inside db 75 °F Design TD 38 °F Design TD 18 °F Daily range M Relative humidity 50 % Moisture difference 52 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 8669 Btuh Structure 7838 Btuh Ducts 1326 Btuh Ducts 1627 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 9995 Btuh Use manufacturer's data n Rate/swing multiplier 0.98 Infiltration Equipment sensible load 14004 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average 1405 Btuh Fireplaces 0 Structure Ducts 273 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh Area(ft2) 925 925 Equipment latent load 2049 Btuh Volume(ft3) 8514 8514 Air changes/hour 0.37 0.20 Equipment total load 16053 Btuh Equiv.AVF(cfm) 53 28 Req.total capacity at 0.70 SHR 1.7 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model CH14NB018 Cond CH14NB018 AHRI ref Coil FB4CNP018 AHRI ref Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 12460 Btuh Heating output 17200 Btuh @ 47°F Latent cooling 17800 Btuh Temperature rise 26 °F Total cooling Actual air flow 593 cfm Actual air flow 593 cfm Air flow factor 0.059 cfm/Btuh Air flow factor 0.063 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.85 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2015-Apr-02 14:49:54 .1_ 'Pk wrightsoft- Comfort Builder by Wrightsoft 15.0.06 RSU12270 Page 2 "A ...NC\Toll Brothers\Anastasia Bonus 3621 left.rup Calc=MJ8 Front Door faces:SW ®® First Floor 16x16 Master Bath �r4 14"0 3"Fan Master Bedroom 10x6 6' • Ad. 12x6 12x6 10. •.. 7" ...7" 4x8 toi 4., ■ v — - 3"Fan his 8 x 4 hers 10' 4.. 8x4 2-way q' 6x12 • 3"Fan 7" 10 x 6 �� 14" • 6" •.ath 3 4x8 Bedroom' 4 12 x 12 8" 2-way r 14x14 6x12 7' Great in 10x6 111 9" 2-way Re:eat 6 x 12 7" 16" Sup Riser 16" Ret Riser Sup Riser 14 12 x 12 10" 8" stairs Ret Riser 10" 8 x 4 18" 0 4, 10x1 - Bedroom 3• �x 8 9' Pantry Hall 1 4" th2 Ldry.1ox10 • 12x6 •F 4x8 12x6 3"Fan 7" ' 4 24x18 7" Dining Foyer Garage 10x6 12x6 6" 7° Study Job#: McGowan's Heating & Air Conditioni... Scale: 1 : 121 Performed by Korey Kasch for: Page 1 Steve Merten 4850 Collins Road Comfort Builder by Wrightsoft 160 Cape May Ave. Orange Park,Fl 32073 15.0.06 RSU12270 Ponce Vedra,Fl 32081 Phone:904-278-0339 Fax:904-278-0366 2015-Apr-02 14:50:28 Phone:(904)217-0739 Fax:(904)814-8173 www.mcgowansac.com korey @mcgowansac.com ...rstAnastasia Bonus 3621 left.rup vtiw✓.tollbrolhers corn smerten @tollbrolhersinc.com • 1v up Y c 8 x 4 12 x 12 3"Fan bed 4 10"rgs 14x6 8" ■ 16. Ret RIE9r Kt_ WSW 10" Sup Riser 10" ,,, Ret Riser 12x6 12x6 18"1 III brows mom J :12 ' a x 4 b wic Job#: McGowan's Heating & Air Conditions... Scale: : 121 Performed by Korey Kasch for: Page 2 Steve Merten 4850 Collins Road Comfort Builder by Wrightsoft 160 Cape May Ave. Orange Park,Fl 32073 15.0.06 RSU12270 Ponce Vedra,Fl 32081 Phone:904-278-0339 Fax:904-278-0366 2015-Apr-02 14:50:28 Phone:(904)217-0739 Fax:(904)814-8173 www.mcgowansac.com korey @mcgowansac.com ...rs\Anastasia Bonus 3621 left.rup www.lollbrothers.com smerten @tollbrothersinc.com Ak Gowan Duct System Summary Date: Heating g (Rest of House) By: Korey Kasch i.K :i...•. McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:korey@mcgowansac.com Web:www.mcgowansac.com Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone: (904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email: smerten @tollbrothersinc.com Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.366/0.134 in H2O 0.366/0.134 in H2O Lowest friction rate 0.086 in/100ft 0.086 in/100ft Actual air flow 1133 cfm 1133 cfm Total effective length(TEL) 581 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk Bath 2 h 197 8 5 0.087 4.0 Ox 0 VIFx 114.8 305.0 st10 Bedroom 2 c 1033 46 62 0.110 6.0 Ox 0 VIFx 82.3 250.0 st9 Bedroom 3 c 1289 76 77 0.087 7.0 Ox 0 VIFx 113.8 305.0 st10 Dining c 1652 84 99 0.184 7.0 Ox0 VIFx 29.5 170.0 st6 Foyer h 2680 107 93 0.171 6.0 Ox 0 VIFx 39.1 175.0 st6 Great Room-A c 2090 110 126 0.187 7.0 Ox 0 VIFx 31.3 165.0 st7 Great Room-B c 2090 110 126 0.175 7.0 Ox 0 VIFx 39.8 170.0 st7 Ili Great Room-c c 2090 110 126 0.175 7.0 Ox 0 VIFx 39.8 170.0 st7 Ldry. h 240 10 8 0.086 4.0 Ox 0 VIFx 120.8 305.0 st10 Master Bath h 2807 112 61 0.105 6.0 Ox 0 VIFx 82.8 265.0 st11 Master Bedroom h 1927 77 75 0.105 7.0 Ox 0 VIFx 84.6 265.0 st11 Master Bedroom-A h 1927 77 75 0.106 7.0 Ox 0 VIFx 80.3 265.0 st11 Pantry h 155 6 4 0.180 4.0 Ox 0 VIFx 28.7 175.0 st6 Retreat c 1082 51 65 0.104 6.0 Ox 0 VIFx 92.3 260.0 st9 Study c 1928 114 116 0.171 7.0 Ox 0 VIFx 39.3 175.0 st6 bath 3 c 9 0 1 0.108 4.0 OX 0 VIFx 84.3 255.0 st9 hers h 559 22 8 0.106 4.0 Ox 0 VIFx 85.3 260.0 st9 his c 5 0 0 0.105 4.0 OX 0 VIFx 87.8 260.0 st9 toilet h 330 13 6 0.105 4.0 Ox 0 VIFx 84.4 265.0 st11 2015-Apr-02 14:49:54 ,c -! wrightsofts Comfort Builder by Wrightsoft 15.0.06 RSU12270 Page 1 /l�t,'+7Ct,+11• ...NC\Toll Brothers\Anastasia Bonus 3621 left.rup Calc=MJ8 Front Door faces:SW Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st6 Peak AVF 311 313 0.171 573 10.0 0 x 0 VinlFlx st2 st10 Peak AVF 94 91 0.086 213 9.0 0 x 0 VinlFlx st9 st9 Peak AVF 214 226 0.086 415 10.0 0 x 0 ViniFlx st8 st11 Peak AVF 279 217 0.105 512 10.0 0 x 0 VinIFIx st8 st8 Peak AVF 493 443 0.086 461 14.0 0 x 0 VinIFIx st7 st7 Peak AVF 822 820 0.086 589 16.0 0 x 0 VinIFIx st3 st2 Peak AVF 311 313 0.171 573 10.0 0 x 0 VinIFIx st3 Peak AVF 822 820 0.086 589 16.0 0 x 0 VinIFIx Return Branch Detail Table Grill Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb5 Ox 0 509 478 155.6 0.086 476 14.0 Ox 0 VIFx rb3 Ox 0 624 655 139.7 0.096 370 18.0 Ox 0 VIFx 2015-Apr-02 14:49:54 .` wrightsoft Comfort Builder by Wrightsoft 15.0.06 RSU12270 Page 2 A,l^.Asp ...NC\Toll Brothers\Anastasia Bonus 3621 left.rup Calc=MJ8 Front Door faces:SW Summary Duct System J° 1 McGowan v •1 Date: Heating ti nni g up By: Korey Kasch ""541,4 McGowan's Heating & Air Conditioning, Inc. 4850 Collins Road,Orange Park,Fl 32073 Phone:904-278-0339 Fax:904-278-0366 Email:korey(dlmcgowansac.com Web:www.mcgowansac.com Project Information For: Steve Merten,Toll Brothers, Inc. 160 Cape May Ave., Ponte Vedra, Fl 32081 Phone:(904)217-0739 Fax: (904)814-8173 Web:www.tollbrothers.com Email:smerten @tollbrothersinc.com Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply/return available pressure 0.337/0.163 in H2O 0.337/0.163 in H2O Lowest friction rate 0.155 in/100ft 0.155 in/100ft Actual air flow 593 cfm 593 cfm Total effective length (TEL) 323 ft Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk b wic h 743 44 29 0.155 4.0 Ox 0 VIFx 37.4 180.0 st5 bath 4 h 466 28 16 0.167 4.0 Ox 0 VIFx 22.3 180.0 st4 bed 4-A h 2171 129 122 0.170 8.0 Ox 0 VIFx 18.2 180.0 st4 bonus room c 2133 109 134 0.162 7.0 Ox 0 VIFx 28.6 180.0 st5 bonus room-A C 2133 109 134 0.161 7.0 Ox 0 VIFx 28.9 180.0 st5 loft h 1198 71 71 0.168 6.0 Ox 0 VIFx 20.6 180.0 st4 loft-B h 1198 71 71 0.169 6.0 Ox 0 VIFx 18.9 180.0 st4 wic h 552 33 17 0.160 4.0 Ox 0 VIFx 30.8 180.0 st4 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st4 Peak AVF 331 297 0.160 608 10.0 0 x 0 VinIFIx st1 st5 Peak AVF 262 296 0.155 544 10.0 0 x 0 VinIFIx st1 st1 Peak AVF 593 593 0.155 555 14.0 0 x 0 VinIFIx 2015-Apr-02 14:49:54 , -P-wrightsoft• Comfort Builder by Wrightsoft 15.0.06 RSU12270 Page 3 ...NC\Toll Brothers\Anastasia Bonus 3621 left.rup Cale=MJ8 Front Door faces:SW 1 Return Branch Detail Table Grill Htg Cig TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening (in) Matl Trunk rb11 Ox 0 153 163 89.1 0.183 299 10.0 Ox 0 VIFx rt1 rb4 Ox 0 233 210 84.6 0.193 427 10.0 Ox 0 VIFx rt1 rb2 Ox 0 207 220 105.1 0.155 498 9.0 Ox 0 VIFx rt1 Return Trunk Detail Table Trunk Htg Cig Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rt1 Peak AVF 593 593 0.155 555 14.0 0 x 0 VinIFIx ll 2015-Apr-02 14:49:54 C AIF wrightsoft' Comfort Builder by Wrightsoft 15.0.06 RSU12270 Page 4 AWK ...NC\Toll Brothers\Anastasia Bonus 3621 left.rup Calc=MJ8 Front Door faces:SW